HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Melville Residence
Builder Name:
Street: 7827 Sabal Lake Drive
Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie, FL , 34950
Permit Number:
Owner: Melville Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type43966.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Polystyrene Bead AggR=4.1 3378.70 ft'
b. Frame - Wood, Adjacent
R=19.0 588.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
11. Ceiling Types (4148.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=30.0 4148.00 ft:
6. Conditioned floor area above grade (ft') 4148
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
7. Windows(779.1 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU
R ft'
6 95
a. U-Factor: Sgl, U=0.66 524.99 ft'
b. Sup: Attic, Ret: Attic, AH: Garage
6 95
SHGC: SHGC=0.21
b. U-Factor: Sgl, U=0.70 180.00 ft'
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.58
a. Central Unit
36.0 SEER:17.00
c. U-Factor: Sgl, U=0.24 50.11 ft'
b. Central Unit
36.0 SEER:17.00
SHGC: SHGC=0.15
Area Weighted Average Overhang Depth: 11.246 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.293
a. Electric Strip Heat
.0 COP:1.00
b. Electric Strip Heat
34.0 COP:1.00
34
8. Skylights Area
c. U-Factor:(AVG) N/A ft'
15. Hot water systems
SHGC(AVG): N/A
a. Propane Tankless
Cap: 1 gallons
9. Floor Types (4148.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 4148.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
16.,Credits
CF, Pstat
Glass/Floor Area: 0.188 Total Proposed Modified Loads: 111.34
PASS
Total Baseline Loads: 122.29
hereby certify that the plans and specifications covered by
Review of the plans and
FpA
this calculation are in compliance with the Florida Energy
specifications covered by this
�Q
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 2-10-2 2
this building will be inspected for
compliance with Section 553.908
V
herebycertify that this building, as designed, is in compliance
fY 95 9 p
Florida Statutes.
with the Florida Energy Code... � i��� J
''•-i,,. ..,�i;yyE-.
w
OWNER/AGENT: `r"�
BUILDING OFFICIAL:
DATE: 2- %2 2
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE Copy
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 9
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Melville Residence
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4148
Lot #
Owner Name:
Melville Residence
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
7827 Sabal Lake Drive
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Port St. Lucie ,
Family Type:
Detached
FL, 34950
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
(Rest of House)
2020
21210
2
Main Area
2128
24191.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Master Bedroom
379
3979.5 No
2
1
1
Yes
Yes
Yes
2
Exercise
121
1270.5 No
1
1
Yes
Yes
Yes
3
WIC 2
64
672 No
0
1
Yes
Yes
Yes
4
Master Bath
203
2131.5 No
1
1
Yes
Yes
Yes
5
Toilet
24
252 No
0
1
No
Yes
Yes
6
Bedroom 4
216
2268 No
2
1
1
Yes
Yes
Yes
7
WIC 1
80
840 No
0
1
No
Yes
Yes
8
Bath 4
66
693 No
0
1
Yes
Yes
Yes
9
Bedroom 3
248
2604 No
2
1
1
Yes
Yes
Yes
10
Bath 3
49
514.5 No
0
1
Yes
Yes
Yes
11
Bath
70
735 No
0
1
Yes
Yes
Yes
12
Bath 2
49
514.5 No
0
1
Yes
Yes
Yes
13
Closet 4
30
315 No
0
1
No
Yes
Yes
14
Linen
16
168 No
0
1
No
Yes
Yes
15
AHU
16
168 No
0
1
No
Yes
Yes
16
Hall
39
409.5 No
0
1
No
Yes
Yes
17
Powder
68
714 No
1
1
No
Yes
Yes
18
Hall
50
525 No
0
1
No
Yes
Yes
19
Bedroom 2
232
2436 No
2
1
1
Yes
Yes
Yes
20
Office
230
2415 No
0
1
Yes
Yes
Yes
21
Hall
24
252 No
0
1
Yes
Yes
Yes
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area
Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
22
Cabana Bath 60
630
No
0
1
Yes
Yes
Yes
23
Laundry 112
1176
No
0
1
Yes
Yes
Yes
24
Den 316
3318
No
1
1
Yes
Yes
Yes
25
Kitchen 263
2761.5
Yes
1
1
No
Yes
Yes
26
Dining 407
5168.9
No
0
1
Yes
Yes
Yes
27
Great Room 414
5299.2
No
1
1
Yes
Yes
Yes
28
Foyer 156
1638
No
0
1
Yes
Yes
Yes
29
Pantry 82
861
No
0
1
No
Yes
Yes
30
Closet 64
672
No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio Master Bedroom
42.8 ft
379 ft'
_---
1
0
0
2 Slab -On -Grade Edge Insulatio
Exercise
27 ft
121 ft'
____
1
0
0
3 Slab -On -Grade Edge Insulatio
WIC 2
7 ft
64 ft'
____
1
0
0
4 Slab -On -Grade Edge Insulatio
Master Bath
18 ft
203 ftZ
-__-
1
0
0
5 Slab -On -Grade Edge Insulatio
Toilet
1 ft
24 ft'
__-_
1
0
0
6 Slab -On -Grade Edge Insulatio
Bedroom 4
15 ft
216 ft'
1
0
0
7 Slab -On -Grade Edge Insulatio
WIC 1
1 ft
80 ft'
_-__
1
0
0
8 Slab -On -Grade Edge Insulatio
Bath 4
6 ft
66 ft'
-_--
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 3
18 ft
248 ftZ
--__
1
0
0
10SIab-On-Grade Edge Insulatio
Bath 3
14 ft
49 ftZ
----
1
0
0
1lSlab-On-Grade Edge Insulatio
Bath
loft
70 ftz
____
1
0
0
12SIab-On-Grade Edge Insulatio
Bath 2
14 ft
49 ft'
__-_
1
0
0
13SIab-On-Grade Edge Insulatio
Closet 4
1 ft
30 ft'
____
1
0
0
14SIab-On-Grade Edge Insulatio
Linen
1 .ft
16 ft'
____
1
0
0
15SIab-On-Grade Edge Insulatio
AHU
1 ft
16 ft'
_--_
1
0
0
16SIab-On-Grade Edge Insulatio
Hall 3
1 ft
39 ft'
---_
1
0
0
17SIab-On-Grade Edge Insulatio
Powder
1 ft
68 ft'
____
1
0
0
18SIab-On-Grade Edge Insulatio
Hall 2
1 ft
50 ft'
1
0
0
19Slab-On-Grade Edge Insulatio
Bedroom 2
19 ft
232 ft'
_-_-
1
0
0
20SIab-On-Grade Edge Insulatio
Office
30 ft
230 ftZ
____
1
0
0
2/10/2021 10:31 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type ,
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
21SIab-On-Grade Edge Insulatio
Hall 1
loft
24 ft2
----
1
0 0
22SIab-On-Grade Edge Insulatio
Cabana Bath
loft
60 ft2
----
1
0 0
23SIab-On-Grade Edge Insulatio
Laundry
7 ft
112 ft2
----
1
0 0
24SIab-On-Grade Edge Insulatio
Den
31 ft
316 ft2
----
1
0 0
25SIab-On-Grade Edge Insulatio
Kitchen
1 ft
263 ft2
----
1
0 0
26SIab-On-Grade Edge Insulatio
Dining
17 ft
407 ft2
__--
1
0 0
27SIab-On-Grade Edge Insulatio
Great Room
18 ft
414 ft2
----
1
0 0
28SIab-On-Grade Edge Insulatio
Foyer
8 ft
156 ft2
----
1
0 0
29SIab-On-Grade Edge Insulatio
Pantry
1 ft
82 ft2
----
1
0 - 0
30SIab-On-Grade Edge Insulatio
Closet
1 ft
64 ft2
----
1
0 0
ROOF
Roof
Gable Roof
Rad
Solar
SA Emitt
Emitt
Deck Pitch
V # Type Materials
Area
Area Color
Barr
Absor.
Tested
Tested
Insul. (deg)
1 Hip
Metal 4639 ft2
0 ft2 Light
N
0.6
No 0.9
No
30 26.6
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0 4148 ft2
N
N
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Master Bedroom 0
Blown
379 ft2
0.1
Wood
2
Under Attic (Unvented) Exercise
0
Blown
121 ft2
0.1
Wood
3
Under Attic (Unvented) WIC 2
0
Blown
64 ft2
0.1
Wood
4
Under Attic (Unvented) Master Bath
0
Blown
203 ft2
0.1
Wood
5
Under Attic (Unvented) Toilet
0
Blown
24 ft2
0.1
Wood
6
Under Attic (Unvented) Bedroom 4
0
Blown
216 ft2
0.1
Wood
7
Under Attic (Unvented) WIC 1
0
Blown
80 ft2
0.1
Wood
8
Under Attic (Unvented) Bath 4
0
Blown
66 ft2
0.1
Wood
9
Under Attic (Unvented) Bedroom 3
0
Blown
248 ft2
0.1
Wood
10
Under Attic (Unvented) Bath 3
0
Blown
49 ft2
0.1
Wood
11
Under Attic (Unvented) Bath
0
Blown
70 ft2
0.1
Wood
12
Under Attic (Unvented) Bath 2
0
Blown
49 ft2
0.1
Wood
13
Under Attic (Unvented) Closet 4
0
Blown
30 ft2
0.1
Wood
14
Under Attic (Unvented) Linen
0
Blown
16 ft2
0.1
Wood
15
Under Attic (Unvented) AHU
0
Blown
16 ft2
0.1
Wood
16
Under Attic (Unvented) Hall 3
0
Blown
39 ft2
0.1
Wood
17
Under Attic (Unvented) Powder
0
Blown
68 ft2
0.1
Wood
18
Under Attic (Unvented) Hall 2
0
Blown
50 ft2
0.1
Wood
19
Under Attic (Unvented) Bedroom 2
0
Blown
232 ft2
0.1
Wood
20
Under Attic (Unvented) Office
0
Blown
230 ft2
0.1
Wood
21
Under Attic (Unvented) Hall 1
0
Blown
24 ft2
0.1
Wood
22
Under Attic (Unvented) Cabana Bath
0
Blown
60 ft2
0.1
Wood
23
Under Attic (Unvented) Laundry
0
Blown
112 ft2
0.1
Wood
24
Under Attic (Unvented) Den
0
Blown
316 ft2
0.1
Wood
25
Under Attic (Unvented) Kitchen
0
Blown
263 ft2
0.1
Wood
26
Under Attic (Unvented) Dining
0
Blown
16 ft2
0.1
Wood
27
Under Attic (Unvented) Dining
0
Blown
391 ft2
0
Wood
28
Under Attic (Unvented) Great Room
0
Blown
414 ft2
0
Wood
29
Under Attic (Unvented) Foyer
0
Blown
156 ft2
0.1
Wood
30
Under Attic (Unvented) Pantry
0
Blown
82 ft2
0.1
Wood
31
Under Attic (Unvented) Closet
0
Blown
64 ft2
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar
Belo w
1
NE
Exterior Concrete Block - Polystkhester Bedro
4.1
17
9 10
6
186.4 ft2
0
0
0.6
0
2
SE
Exterior Concrete Block - Polystkhester Bedro
4.1
6
0 10
6
63.0 ft2
0
0
0.6
0
3
NW
Exterior Concrete Block - Polystyhester Bedro
4.1
19
0 10
6
199.5 ft2
0
0
0.6
0
4
NE
Exterior Concrete Block - PolystyrE&ercise
4.1
9
0 10
6
94.5 ft2
0
0
0.6
0
5
SE
Exterior Concrete Block - PolystyrE&ercise
4.1
14
0 10
6
147.0 ft2
0
0
0.6
0
6
SW
Exterior Concrete Block - PolystyrE&ercise
4.1
4 ^
0 10
6
42.0 ft2
0
0
0.6
0
7
SE
Exterior Concrete Block - PolystyrerWIC 2
4.1
7
0 10
6
73.5 ft2
0
0
0.6
0
8
SE
Exterior Concrete Block - Polysty bWBter Bath
4.1
11
0 10
6
115.5 ft2
0
0
0.6
0
_ 9
SW
Exterior Concrete Block - Polystyfrmster Bath
4.1
7
0 10
6
73.5 ft2
0
0
0.6
0
2/10/2021 10:31 AM 7.0.00 - FlaRe's202O FBC 7th Edition (2020) Compliant Software Page 5 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity,
Width
Height
Sheathing Framing
Solar
Below
10
NE
Exterior
Concrete Block - PolystyRed room 4
4.1
1
0
10
6
10.5 ft2
0
0
0.6
0
11
SE
Exterior
Concrete Block - PolystyFadroom 4
4.1
13
0
10
6
136.5 ft2
0
0
0.6
0
12
SW
Exterior
Concrete Block - Polystyfiodroom 4
4.1
1
0
10
6
10.5 ft2
0
0
0.6
0
_ 13
SE
Exterior
Concrete Block - PolystyrerBath 4
4.1
6
0
10
6
63.0 ft2
0
0
0.6
0
14
NE
Exterior
Concrete Block - Polystyfi-droom 3
4.1
2
0
10
6
21.0 ft2
0
0
0.6
0
15
SE
Exterior
Concrete Block - Polysty&-vdroom 3
4.1
16
0
10
6
168.0 ft2
0
0
0.6
0
16
SE
Exterior
Concrete Block - PolystyrerBath 3
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
17
SW
Exterior
Concrete Block - Polystyred3ath 3
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
18
SW
Exterior
Concrete Block - Polystyren Bath
4.1
10
0
10
6
105.0 ft2
0
0
0.6
0
19
SW
Exterior
Concrete Block - PolystyrerBath 2
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
_20
NW
Exterior
Concrete Block - PolystyrerBath 2
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
_21
SW
Exterior
Concrete Block - PolystygiWroom 2
4.1
6
0
10
6
63.0 ft2
0
0
0.6
0
_22
NW
Exterior
Concrete Block - Polysty&-, Broom 2
4.1
13
0
10
6
136.5 ft2
0
0
0.6
0
23
SE
Exterior
Concrete Block - PolystyrerOffrce
4.1
5
0
10
6
52.5 ft2
0
0
0.6
0
24
SW
Exterior
Concrete Block - PolystyrerOffrce
4.1
17
0
10
6
178.5 ft2
0
0
0.6
0
25
NW
Exterior
Concrete Block - PolystyrerOffrce
4.1
8
0
10
6
84.0 ft2
0
0
0.6
0
_26
NE
Exterior
Concrete Block - PolystyrerHall 1
4.1
6
0
10
6
63.0 ft2
0
0
0.6
0
_27
NW
Exterior
Concrete Block - PolystyrerHall 1
4.1
4
0
10
6
42.0 ft2
0
0
0.6
0
_28
NW
Exterior
Concrete Block - Polyst!pehana Bath
4.1
10
0
10
6
105.0 ft2
0
0
0.6
0
_29
NW
Exterior
Concrete Block - Polystyreinaundry
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
_ 30
NE
Exterior
Concrete Block - Polystyren Den
4.1
19
0
10
6
199.5 ft2
0
0
0.6
0
31
E
Exterior
Concrete Block - Polystyren Den
4.1
5
0
10
6
52.5 ft2
0
0
0.6
0
32
SE
Exterior
Concrete Block - Polystyren Den
4.1
7
0
10
6
73.5 ft2
0
0
0.6
0
_ 33
NE
Exterior
Concrete Block - PolystyrerDining
4.1
14
0
12
9
178.512
0
0
0.6
0
34
NE
Exterior
Concrete Block - PolystVDyeat Room
4.1
14
9
12
10
189.3 ft2
0
0
0.6
0
35
SW
Exterior
Concrete Block - PolystyrerFoyer
4.1
8
0
10
6
84.0 ft2
0
0
0.6
0
_ 36
SW
Garage
Frame - Wood Laundry
19
16
10.5
168.0 ft2
0.23
0.6
0
37
N
Garage
Frame - Wood Kitchen
19
12
10.5
126.0 ft2.
0.23
0.6
0
38
SW
Garage
Frame - Wood Kitchen
19
2
10.5
21.0 ft2
0.23
0.6
0
39
N
Garage
Frame - Wood Kitchen
19
5
10.5
52.5 ft2
0.23
0.6
0
40
SW
Garage
Frame - Wood Kitchen
19
5
10.5
52.5 ft2
0.23
0.6
0
_41
N
Garage
Frame - Wood Pantry
19
7
10.5
73.5 ft2
0.23
0.6
0
_42
SW
Garage
Frame - Wood Pantry
19
3
10.5
31.5 ft2
0.23
0.6
0
_ 43
N
Garage
Frame - Wood Office
19
6
10.5
63.0 ft2
0.23
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
LI-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Master Bedro
None
.2
.1
.1
.1 ft2
2/10/2021 10:31 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE
1
Metal
Low-E Single
Yes
0.66
0.21
Y
19.0 ft2
2 ft 7 in
1 ft 4 in
None
None
2
NE
1
Metal
Low-E Single
Yes
0.66
0.21
Y
19.5 ft2
2 ft 7 in
1 ft 4 in
None
None
3
NE
1
Metal
Low-E Single
Yes
0.66
0.21
Y
27.4 ft2
12 ft 0 in
1 ft 4 in
None
None
4
SE
2
Metal
Low-E Single
Yes
0.66
0.21
Y
19.5 ft2
2 ft 7 in
1 ft 4 in
None
None
5
NE
4
Metal
Low-E Single
Yes
0.66
0.21
Y
25.3 ft2
2 ft 7 in
1 ft 4 in
None
None
6
SE
5
Metal
Low-E Single
Yes
0.66
0.21
Y
39.1 ft2
2 ft 7 in
1 ft4 in
None
None
7
SE
7
Metal
Low-E Single
Yes
0.66
0.21
Y
10.7 ft2
2 ft 7 in
1 ft4 in
None
None
8
SE
8
Metal
Low-E Single
Yes
0.66
0.21
Y
6.0 ft2
2 ft 7 in
1 ft 4 in
None
None
9
SE
8
Metal
Low-E Single
Yes
0.66
0.21
Y
15.0 ft2
2 ft 7 in
1 ft4 in
None
None
10
SE
11
Metal
Low-E Single
Yes
0.66
0.21
Y
15.0 ft2
2 ft 7 in
1 ft 4 in
None
None
11
SE
13
Metal
Low-E Single
Yes
0.66
0.21
Y
6.0 ft2
2 ft 7 in
1 ft 4 in
None
None
12
SE
15
Metal
Low-E Single
Yes
0.66
0.21
Y
22.5 ft2
2 ft 7 in
1 ft 4 in
None
None
13
SE
16
Metal
Low-E Single
Yes
0.66
0.21
Y
4.8 ft2
2 ft 7 in
1 ft 4 in
None
None
14
SW
18
Metal
Low-E Single
Yes
0.66
0.21
Y
12.0 ft2
2 ft 7 in
1 ft 4 in
None
None
15
NW
20
Metal
Low-E Single
Yes
0.66
0.21
Y
4.8 ft2
2 ft 7 in
1 ft4 in
None
None
16
SW
21
Metal
Low-E Single
Yes
0.66
0.21
Y
15.0 ft2
2 ft 7 in
1 ft 4 in
None
None
17
SW
24
Metal
Low-E Single
Yes
0.66
0.21
Y
57.0 ft2
9 ft 0 in
1 ft 4 in
None
None
18
NW
25
Metal
Low-E Single
Yes
0.66
0.21
Y
19.0 ft2
9 ft 0 in
1 ft 4 in
None
None
19
NE
26
Metal
Low-E Single
Yes
0.24
0.15
Y
22.7 ft2
6 ft 0 in
1 ft 4 in
None
None
20
NW
28
Metal
Low-E Single
Yes
0.66
0.21
Y
4.0 ft2
2 ft 7 in
1 ft 4 in
None
None
21
NW
29
Metal
Low-E Single
Yes
0.66
0.21
Y
15.0 ft2
2 ft 7 in
1 ft 4 in
None
None
22
NE
30
Metal
Low-E Single
Yes
0.66
0.21
Y
24.0 ft2
12 ft 0 in
1 ft 4 in
None
None
23
NE
30
Metal
Low-E Single
Yes
0.66
0.21
Y
57.0 ft2
12 ft 0 in
1 ft 4 in
None
None
24
E
31
Metal
Low-E Single
Yes
0.24
0.15
Y
27.4 ft2
12 ft 0 in
1 ft4 in
None
None
25
SE
32
Metal
Low-E Single
Yes
0.66
0.21
Y
19.0 ft2
12 ft 0 in
1 ft4 in
None
None
26
NE
33
Metal
Low-E Single
Yes
0.7
0.58
Y
90.0 ft2
24 ft 0 in
1 ft4 in
None
None
27
NE
33
Metal
Low-E Single
Yes
0.66
0.21
Y
17.0 ft2
12 ft 0 in
1 ft 4 in
None
None
28
NE
34
Metal
Low-E Single
Yes
0.7
0.58
Y
90.0 ft2
24 ft 0 in
1 ft 4 in
None
None
29
NE
34
Metal
Low-E Single
Yes
0.66
0.21
Y
17.0 ft2
12 ft 0 in
1 ft 4 in
None
None
30
NE
34
Metal
Low-E Single
Yes
0.66
0.21
Y
18.4 ft2
12 ft 0 in
1 ft 4 in
None
None
31
SW
35
Wood
Low-E Single
Yes
0.28
0.26
Y
24.0 ft2
12 ft 0 in
1 ft 4 in
None
None
32
SW
35
Metal
Low-E Single
Yes
0.66
0.21
Y
16.0 ft2
12 ft 0 in
1 ft4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
864 ft2
864 ft2
53 ft
10.5 ft
19
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000487
5296.9 290.6 545.57 .1432 7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
2 Electric Strip Heat/
None
None
COP:1 27 kBtu/hr
COP:1 34 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR
Block
Ducts
1 Central Unit/
2 Central Unit/
Split
Split
Singl SEER: 17 ' 36 kBtu/hr 1080 cfm 0.7
Singl SEER: 17 36 kBtu/hr 1080 cfm 0.7
1
2
sys#1
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Propane Tankless
Exterior
0.6 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
--- Supply ---
V # Location R-Value Area
-- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 95 ft2
2 Attic 6 95 ft'
Attic
Attic
20 ft' Default Leakage AHU (Default) (Default)
25 ftz Default Leakage Garage (Default) (Default)
1 1
2 2
TEMPERATURES
Programable Thermostat: Y
Heating [X] Jan H Mar
Feb ki
Venting [] Jan Feb Mar
Ceiling Fans:
Act
pr JM
May �AprXl Jun riJul rlAug riSep Oct
Jun Jul Aug Sep
Nov
XNov
Dec
Dec
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 9
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Exercise
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Closet 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Linen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Powder
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Office
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Cabana Bath
Default(8 Ibs/sq.ft.
ft2
ft.
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Den
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Great Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/s .ft.
ft2
ft
0.3
Closet
2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 9 of 9
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
7827 Sabal Lake Drive, Port St. Lucie, FL, 34950
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Polystyrene Bead Agg2=4.1
3378.70 ft2
b. Frame - Wood, Adjacent
R=19.0
588.00 ft
3. Number of units, if multiple family
1
c. N/A
R=
ftZ
4. Number of Bedrooms
4
d. N/A
R=
ftZ
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=30.0
4148.00 ftZ
6. Conditioned floor area (ftZ)
4148
b. N/A
R=
ftZ
c. N/A
R=
ftZ
7. Windows- Description
Area
12. Ducts, location & insulation level
R ftZ
a. U-Factor: Sgl, U=0.66
524.99 ftZ
a. Sup: Attic, Ret: Attic, AH: AHU
6 95
SHGC: SHGC=0.21
b. Sup: Attic, Ret: Attic, AH: Garage
6 95
b. U-Factor: Sgl, U=0.70
180.00 ftZ
SHGC: SHGC=0.58
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Sgl, U=0.24
50.11 ftZ
a. Central Unit
34.4 SEER:17.00
SHGC: SHGC=0.15
b. Central Unit
34.4 SEER:17.00
d. U-Factor: other (see details)
24.00 ftZ
14. Heating systems
kBtu/hr
Efficiency
SHGC: other (see details)
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average Overhang Depth:
11.246 ft.
b. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average SHGC:
0.293
8. Skylights Description
Area
15. Hot water systems
Cap:
1 gallons
a. U-Factor(AVG): N/A
ftZ
a. Propane
EF: 0.6
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
4148.00 ftZ
Credits (Performance method)
CF, Pstat
b. N/A
R=
ftZ
c. N/A
R=
ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant feature$.
Builder Signature: JMALA � Date: 2- tZ - 2 o2 �
Address of New Home: %-3 21 S4 6c l Led� 9ri,, City/FL Zip: PS L F�
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/9/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FILE COPY
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Melville Residence Builder Name:
Street: 7827 Sabal Lake Drive Permit Office: St. Lucie County
City, State, Zip: Port St. Lucie, FL , 34950 Permit Number:
Y
U
Owner: Melville Residence Jurisdiction: St. Lucie County
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and an gaps in the air barrier shall be sealed.
Y 9 P
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between cover nlates and wall ceilino
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2/9/2021 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1