Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Melville Residence Builder Name: Street: 7827 Sabal Lake Drive Permit Office: St. Lucie County City, State, Zip: Port St. Lucie, FL , 34950 Permit Number: Owner: Melville Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type43966.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead AggR=4.1 3378.70 ft' b. Frame - Wood, Adjacent R=19.0 588.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft' 11. Ceiling Types (4148.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 4148.00 ft: 6. Conditioned floor area above grade (ft') 4148 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 7. Windows(779.1 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU R ft' 6 95 a. U-Factor: Sgl, U=0.66 524.99 ft' b. Sup: Attic, Ret: Attic, AH: Garage 6 95 SHGC: SHGC=0.21 b. U-Factor: Sgl, U=0.70 180.00 ft' 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.58 a. Central Unit 36.0 SEER:17.00 c. U-Factor: Sgl, U=0.24 50.11 ft' b. Central Unit 36.0 SEER:17.00 SHGC: SHGC=0.15 Area Weighted Average Overhang Depth: 11.246 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.293 a. Electric Strip Heat .0 COP:1.00 b. Electric Strip Heat 34.0 COP:1.00 34 8. Skylights Area c. U-Factor:(AVG) N/A ft' 15. Hot water systems SHGC(AVG): N/A a. Propane Tankless Cap: 1 gallons 9. Floor Types (4148.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 4148.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 16.,Credits CF, Pstat Glass/Floor Area: 0.188 Total Proposed Modified Loads: 111.34 PASS Total Baseline Loads: 122.29 hereby certify that the plans and specifications covered by Review of the plans and FpA this calculation are in compliance with the Florida Energy specifications covered by this �Q Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 2-10-2 2 this building will be inspected for compliance with Section 553.908 V herebycertify that this building, as designed, is in compliance fY 95 9 p Florida Statutes. with the Florida Energy Code... � i��� J ''•-i,,. ..,�i;yyE-. w OWNER/AGENT: `r"� BUILDING OFFICIAL: DATE: 2- %2 2 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE Copy 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Melville Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4148 Lot # Owner Name: Melville Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 7827 Sabal Lake Drive Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: Detached FL, 34950 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 (Rest of House) 2020 21210 2 Main Area 2128 24191.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 379 3979.5 No 2 1 1 Yes Yes Yes 2 Exercise 121 1270.5 No 1 1 Yes Yes Yes 3 WIC 2 64 672 No 0 1 Yes Yes Yes 4 Master Bath 203 2131.5 No 1 1 Yes Yes Yes 5 Toilet 24 252 No 0 1 No Yes Yes 6 Bedroom 4 216 2268 No 2 1 1 Yes Yes Yes 7 WIC 1 80 840 No 0 1 No Yes Yes 8 Bath 4 66 693 No 0 1 Yes Yes Yes 9 Bedroom 3 248 2604 No 2 1 1 Yes Yes Yes 10 Bath 3 49 514.5 No 0 1 Yes Yes Yes 11 Bath 70 735 No 0 1 Yes Yes Yes 12 Bath 2 49 514.5 No 0 1 Yes Yes Yes 13 Closet 4 30 315 No 0 1 No Yes Yes 14 Linen 16 168 No 0 1 No Yes Yes 15 AHU 16 168 No 0 1 No Yes Yes 16 Hall 39 409.5 No 0 1 No Yes Yes 17 Powder 68 714 No 1 1 No Yes Yes 18 Hall 50 525 No 0 1 No Yes Yes 19 Bedroom 2 232 2436 No 2 1 1 Yes Yes Yes 20 Office 230 2415 No 0 1 Yes Yes Yes 21 Hall 24 252 No 0 1 Yes Yes Yes 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 Cabana Bath 60 630 No 0 1 Yes Yes Yes 23 Laundry 112 1176 No 0 1 Yes Yes Yes 24 Den 316 3318 No 1 1 Yes Yes Yes 25 Kitchen 263 2761.5 Yes 1 1 No Yes Yes 26 Dining 407 5168.9 No 0 1 Yes Yes Yes 27 Great Room 414 5299.2 No 1 1 Yes Yes Yes 28 Foyer 156 1638 No 0 1 Yes Yes Yes 29 Pantry 82 861 No 0 1 No Yes Yes 30 Closet 64 672 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 42.8 ft 379 ft' _--- 1 0 0 2 Slab -On -Grade Edge Insulatio Exercise 27 ft 121 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulatio WIC 2 7 ft 64 ft' ____ 1 0 0 4 Slab -On -Grade Edge Insulatio Master Bath 18 ft 203 ftZ -__- 1 0 0 5 Slab -On -Grade Edge Insulatio Toilet 1 ft 24 ft' __-_ 1 0 0 6 Slab -On -Grade Edge Insulatio Bedroom 4 15 ft 216 ft' 1 0 0 7 Slab -On -Grade Edge Insulatio WIC 1 1 ft 80 ft' _-__ 1 0 0 8 Slab -On -Grade Edge Insulatio Bath 4 6 ft 66 ft' -_-- 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 18 ft 248 ftZ --__ 1 0 0 10SIab-On-Grade Edge Insulatio Bath 3 14 ft 49 ftZ ---- 1 0 0 1lSlab-On-Grade Edge Insulatio Bath loft 70 ftz ____ 1 0 0 12SIab-On-Grade Edge Insulatio Bath 2 14 ft 49 ft' __-_ 1 0 0 13SIab-On-Grade Edge Insulatio Closet 4 1 ft 30 ft' ____ 1 0 0 14SIab-On-Grade Edge Insulatio Linen 1 .ft 16 ft' ____ 1 0 0 15SIab-On-Grade Edge Insulatio AHU 1 ft 16 ft' _--_ 1 0 0 16SIab-On-Grade Edge Insulatio Hall 3 1 ft 39 ft' ---_ 1 0 0 17SIab-On-Grade Edge Insulatio Powder 1 ft 68 ft' ____ 1 0 0 18SIab-On-Grade Edge Insulatio Hall 2 1 ft 50 ft' 1 0 0 19Slab-On-Grade Edge Insulatio Bedroom 2 19 ft 232 ft' _-_- 1 0 0 20SIab-On-Grade Edge Insulatio Office 30 ft 230 ftZ ____ 1 0 0 2/10/2021 10:31 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type , Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 21SIab-On-Grade Edge Insulatio Hall 1 loft 24 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulatio Cabana Bath loft 60 ft2 ---- 1 0 0 23SIab-On-Grade Edge Insulatio Laundry 7 ft 112 ft2 ---- 1 0 0 24SIab-On-Grade Edge Insulatio Den 31 ft 316 ft2 ---- 1 0 0 25SIab-On-Grade Edge Insulatio Kitchen 1 ft 263 ft2 ---- 1 0 0 26SIab-On-Grade Edge Insulatio Dining 17 ft 407 ft2 __-- 1 0 0 27SIab-On-Grade Edge Insulatio Great Room 18 ft 414 ft2 ---- 1 0 0 28SIab-On-Grade Edge Insulatio Foyer 8 ft 156 ft2 ---- 1 0 0 29SIab-On-Grade Edge Insulatio Pantry 1 ft 82 ft2 ---- 1 0 - 0 30SIab-On-Grade Edge Insulatio Closet 1 ft 64 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 4639 ft2 0 ft2 Light N 0.6 No 0.9 No 30 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4148 ft2 N N 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Bedroom 0 Blown 379 ft2 0.1 Wood 2 Under Attic (Unvented) Exercise 0 Blown 121 ft2 0.1 Wood 3 Under Attic (Unvented) WIC 2 0 Blown 64 ft2 0.1 Wood 4 Under Attic (Unvented) Master Bath 0 Blown 203 ft2 0.1 Wood 5 Under Attic (Unvented) Toilet 0 Blown 24 ft2 0.1 Wood 6 Under Attic (Unvented) Bedroom 4 0 Blown 216 ft2 0.1 Wood 7 Under Attic (Unvented) WIC 1 0 Blown 80 ft2 0.1 Wood 8 Under Attic (Unvented) Bath 4 0 Blown 66 ft2 0.1 Wood 9 Under Attic (Unvented) Bedroom 3 0 Blown 248 ft2 0.1 Wood 10 Under Attic (Unvented) Bath 3 0 Blown 49 ft2 0.1 Wood 11 Under Attic (Unvented) Bath 0 Blown 70 ft2 0.1 Wood 12 Under Attic (Unvented) Bath 2 0 Blown 49 ft2 0.1 Wood 13 Under Attic (Unvented) Closet 4 0 Blown 30 ft2 0.1 Wood 14 Under Attic (Unvented) Linen 0 Blown 16 ft2 0.1 Wood 15 Under Attic (Unvented) AHU 0 Blown 16 ft2 0.1 Wood 16 Under Attic (Unvented) Hall 3 0 Blown 39 ft2 0.1 Wood 17 Under Attic (Unvented) Powder 0 Blown 68 ft2 0.1 Wood 18 Under Attic (Unvented) Hall 2 0 Blown 50 ft2 0.1 Wood 19 Under Attic (Unvented) Bedroom 2 0 Blown 232 ft2 0.1 Wood 20 Under Attic (Unvented) Office 0 Blown 230 ft2 0.1 Wood 21 Under Attic (Unvented) Hall 1 0 Blown 24 ft2 0.1 Wood 22 Under Attic (Unvented) Cabana Bath 0 Blown 60 ft2 0.1 Wood 23 Under Attic (Unvented) Laundry 0 Blown 112 ft2 0.1 Wood 24 Under Attic (Unvented) Den 0 Blown 316 ft2 0.1 Wood 25 Under Attic (Unvented) Kitchen 0 Blown 263 ft2 0.1 Wood 26 Under Attic (Unvented) Dining 0 Blown 16 ft2 0.1 Wood 27 Under Attic (Unvented) Dining 0 Blown 391 ft2 0 Wood 28 Under Attic (Unvented) Great Room 0 Blown 414 ft2 0 Wood 29 Under Attic (Unvented) Foyer 0 Blown 156 ft2 0.1 Wood 30 Under Attic (Unvented) Pantry 0 Blown 82 ft2 0.1 Wood 31 Under Attic (Unvented) Closet 0 Blown 64 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 NE Exterior Concrete Block - Polystkhester Bedro 4.1 17 9 10 6 186.4 ft2 0 0 0.6 0 2 SE Exterior Concrete Block - Polystkhester Bedro 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0 3 NW Exterior Concrete Block - Polystyhester Bedro 4.1 19 0 10 6 199.5 ft2 0 0 0.6 0 4 NE Exterior Concrete Block - PolystyrE&ercise 4.1 9 0 10 6 94.5 ft2 0 0 0.6 0 5 SE Exterior Concrete Block - PolystyrE&ercise 4.1 14 0 10 6 147.0 ft2 0 0 0.6 0 6 SW Exterior Concrete Block - PolystyrE&ercise 4.1 4 ^ 0 10 6 42.0 ft2 0 0 0.6 0 7 SE Exterior Concrete Block - PolystyrerWIC 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 8 SE Exterior Concrete Block - Polysty bWBter Bath 4.1 11 0 10 6 115.5 ft2 0 0 0.6 0 _ 9 SW Exterior Concrete Block - Polystyfrmster Bath 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 2/10/2021 10:31 AM 7.0.00 - FlaRe's202O FBC 7th Edition (2020) Compliant Software Page 5 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity, Width Height Sheathing Framing Solar Below 10 NE Exterior Concrete Block - PolystyRed room 4 4.1 1 0 10 6 10.5 ft2 0 0 0.6 0 11 SE Exterior Concrete Block - PolystyFadroom 4 4.1 13 0 10 6 136.5 ft2 0 0 0.6 0 12 SW Exterior Concrete Block - Polystyfiodroom 4 4.1 1 0 10 6 10.5 ft2 0 0 0.6 0 _ 13 SE Exterior Concrete Block - PolystyrerBath 4 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0 14 NE Exterior Concrete Block - Polystyfi-droom 3 4.1 2 0 10 6 21.0 ft2 0 0 0.6 0 15 SE Exterior Concrete Block - Polysty&-vdroom 3 4.1 16 0 10 6 168.0 ft2 0 0 0.6 0 16 SE Exterior Concrete Block - PolystyrerBath 3 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 17 SW Exterior Concrete Block - Polystyred3ath 3 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 18 SW Exterior Concrete Block - Polystyren Bath 4.1 10 0 10 6 105.0 ft2 0 0 0.6 0 19 SW Exterior Concrete Block - PolystyrerBath 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 _20 NW Exterior Concrete Block - PolystyrerBath 2 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 _21 SW Exterior Concrete Block - PolystygiWroom 2 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0 _22 NW Exterior Concrete Block - Polysty&-, Broom 2 4.1 13 0 10 6 136.5 ft2 0 0 0.6 0 23 SE Exterior Concrete Block - PolystyrerOffrce 4.1 5 0 10 6 52.5 ft2 0 0 0.6 0 24 SW Exterior Concrete Block - PolystyrerOffrce 4.1 17 0 10 6 178.5 ft2 0 0 0.6 0 25 NW Exterior Concrete Block - PolystyrerOffrce 4.1 8 0 10 6 84.0 ft2 0 0 0.6 0 _26 NE Exterior Concrete Block - PolystyrerHall 1 4.1 6 0 10 6 63.0 ft2 0 0 0.6 0 _27 NW Exterior Concrete Block - PolystyrerHall 1 4.1 4 0 10 6 42.0 ft2 0 0 0.6 0 _28 NW Exterior Concrete Block - Polyst!pehana Bath 4.1 10 0 10 6 105.0 ft2 0 0 0.6 0 _29 NW Exterior Concrete Block - Polystyreinaundry 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 _ 30 NE Exterior Concrete Block - Polystyren Den 4.1 19 0 10 6 199.5 ft2 0 0 0.6 0 31 E Exterior Concrete Block - Polystyren Den 4.1 5 0 10 6 52.5 ft2 0 0 0.6 0 32 SE Exterior Concrete Block - Polystyren Den 4.1 7 0 10 6 73.5 ft2 0 0 0.6 0 _ 33 NE Exterior Concrete Block - PolystyrerDining 4.1 14 0 12 9 178.512 0 0 0.6 0 34 NE Exterior Concrete Block - PolystVDyeat Room 4.1 14 9 12 10 189.3 ft2 0 0 0.6 0 35 SW Exterior Concrete Block - PolystyrerFoyer 4.1 8 0 10 6 84.0 ft2 0 0 0.6 0 _ 36 SW Garage Frame - Wood Laundry 19 16 10.5 168.0 ft2 0.23 0.6 0 37 N Garage Frame - Wood Kitchen 19 12 10.5 126.0 ft2. 0.23 0.6 0 38 SW Garage Frame - Wood Kitchen 19 2 10.5 21.0 ft2 0.23 0.6 0 39 N Garage Frame - Wood Kitchen 19 5 10.5 52.5 ft2 0.23 0.6 0 40 SW Garage Frame - Wood Kitchen 19 5 10.5 52.5 ft2 0.23 0.6 0 _41 N Garage Frame - Wood Pantry 19 7 10.5 73.5 ft2 0.23 0.6 0 _42 SW Garage Frame - Wood Pantry 19 3 10.5 31.5 ft2 0.23 0.6 0 _ 43 N Garage Frame - Wood Office 19 6 10.5 63.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms LI-Value Width Height Area Ft In Ft In 1 N Wood Master Bedro None .2 .1 .1 .1 ft2 2/10/2021 10:31 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Single Yes 0.66 0.21 Y 19.0 ft2 2 ft 7 in 1 ft 4 in None None 2 NE 1 Metal Low-E Single Yes 0.66 0.21 Y 19.5 ft2 2 ft 7 in 1 ft 4 in None None 3 NE 1 Metal Low-E Single Yes 0.66 0.21 Y 27.4 ft2 12 ft 0 in 1 ft 4 in None None 4 SE 2 Metal Low-E Single Yes 0.66 0.21 Y 19.5 ft2 2 ft 7 in 1 ft 4 in None None 5 NE 4 Metal Low-E Single Yes 0.66 0.21 Y 25.3 ft2 2 ft 7 in 1 ft 4 in None None 6 SE 5 Metal Low-E Single Yes 0.66 0.21 Y 39.1 ft2 2 ft 7 in 1 ft4 in None None 7 SE 7 Metal Low-E Single Yes 0.66 0.21 Y 10.7 ft2 2 ft 7 in 1 ft4 in None None 8 SE 8 Metal Low-E Single Yes 0.66 0.21 Y 6.0 ft2 2 ft 7 in 1 ft 4 in None None 9 SE 8 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft4 in None None 10 SE 11 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None 11 SE 13 Metal Low-E Single Yes 0.66 0.21 Y 6.0 ft2 2 ft 7 in 1 ft 4 in None None 12 SE 15 Metal Low-E Single Yes 0.66 0.21 Y 22.5 ft2 2 ft 7 in 1 ft 4 in None None 13 SE 16 Metal Low-E Single Yes 0.66 0.21 Y 4.8 ft2 2 ft 7 in 1 ft 4 in None None 14 SW 18 Metal Low-E Single Yes 0.66 0.21 Y 12.0 ft2 2 ft 7 in 1 ft 4 in None None 15 NW 20 Metal Low-E Single Yes 0.66 0.21 Y 4.8 ft2 2 ft 7 in 1 ft4 in None None 16 SW 21 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None 17 SW 24 Metal Low-E Single Yes 0.66 0.21 Y 57.0 ft2 9 ft 0 in 1 ft 4 in None None 18 NW 25 Metal Low-E Single Yes 0.66 0.21 Y 19.0 ft2 9 ft 0 in 1 ft 4 in None None 19 NE 26 Metal Low-E Single Yes 0.24 0.15 Y 22.7 ft2 6 ft 0 in 1 ft 4 in None None 20 NW 28 Metal Low-E Single Yes 0.66 0.21 Y 4.0 ft2 2 ft 7 in 1 ft 4 in None None 21 NW 29 Metal Low-E Single Yes 0.66 0.21 Y 15.0 ft2 2 ft 7 in 1 ft 4 in None None 22 NE 30 Metal Low-E Single Yes 0.66 0.21 Y 24.0 ft2 12 ft 0 in 1 ft 4 in None None 23 NE 30 Metal Low-E Single Yes 0.66 0.21 Y 57.0 ft2 12 ft 0 in 1 ft 4 in None None 24 E 31 Metal Low-E Single Yes 0.24 0.15 Y 27.4 ft2 12 ft 0 in 1 ft4 in None None 25 SE 32 Metal Low-E Single Yes 0.66 0.21 Y 19.0 ft2 12 ft 0 in 1 ft4 in None None 26 NE 33 Metal Low-E Single Yes 0.7 0.58 Y 90.0 ft2 24 ft 0 in 1 ft4 in None None 27 NE 33 Metal Low-E Single Yes 0.66 0.21 Y 17.0 ft2 12 ft 0 in 1 ft 4 in None None 28 NE 34 Metal Low-E Single Yes 0.7 0.58 Y 90.0 ft2 24 ft 0 in 1 ft 4 in None None 29 NE 34 Metal Low-E Single Yes 0.66 0.21 Y 17.0 ft2 12 ft 0 in 1 ft 4 in None None 30 NE 34 Metal Low-E Single Yes 0.66 0.21 Y 18.4 ft2 12 ft 0 in 1 ft 4 in None None 31 SW 35 Wood Low-E Single Yes 0.28 0.26 Y 24.0 ft2 12 ft 0 in 1 ft 4 in None None 32 SW 35 Metal Low-E Single Yes 0.66 0.21 Y 16.0 ft2 12 ft 0 in 1 ft4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 864 ft2 864 ft2 53 ft 10.5 ft 19 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000487 5296.9 290.6 545.57 .1432 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ 2 Electric Strip Heat/ None None COP:1 27 kBtu/hr COP:1 34 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ 2 Central Unit/ Split Split Singl SEER: 17 ' 36 kBtu/hr 1080 cfm 0.7 Singl SEER: 17 36 kBtu/hr 1080 cfm 0.7 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS --- Supply --- V # Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 95 ft2 2 Attic 6 95 ft' Attic Attic 20 ft' Default Leakage AHU (Default) (Default) 25 ftz Default Leakage Garage (Default) (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y Heating [X] Jan H Mar Feb ki Venting [] Jan Feb Mar Ceiling Fans: Act pr JM May �AprXl Jun riJul rlAug riSep Oct Jun Jul Aug Sep Nov XNov Dec Dec 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 9 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Exercise Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Linen Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Powder Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Office Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Cabana Bath Default(8 Ibs/sq.ft. ft2 ft. 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/s .ft. ft2 ft 0.3 Closet 2/10/2021 10:31 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 9 of 9 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 7827 Sabal Lake Drive, Port St. Lucie, FL, 34950 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Polystyrene Bead Agg2=4.1 3378.70 ft2 b. Frame - Wood, Adjacent R=19.0 588.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 4148.00 ftZ 6. Conditioned floor area (ftZ) 4148 b. N/A R= ftZ c. N/A R= ftZ 7. Windows- Description Area 12. Ducts, location & insulation level R ftZ a. U-Factor: Sgl, U=0.66 524.99 ftZ a. Sup: Attic, Ret: Attic, AH: AHU 6 95 SHGC: SHGC=0.21 b. Sup: Attic, Ret: Attic, AH: Garage 6 95 b. U-Factor: Sgl, U=0.70 180.00 ftZ SHGC: SHGC=0.58 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.24 50.11 ftZ a. Central Unit 34.4 SEER:17.00 SHGC: SHGC=0.15 b. Central Unit 34.4 SEER:17.00 d. U-Factor: other (see details) 24.00 ftZ 14. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 11.246 ft. b. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average SHGC: 0.293 8. Skylights Description Area 15. Hot water systems Cap: 1 gallons a. U-Factor(AVG): N/A ftZ a. Propane EF: 0.6 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 4148.00 ftZ Credits (Performance method) CF, Pstat b. N/A R= ftZ c. N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature$. Builder Signature: JMALA � Date: 2- tZ - 2 o2 � Address of New Home: %-3 21 S4 6c l Led� 9ri,, City/FL Zip: PS L F� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/9/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FILE COPY 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Melville Residence Builder Name: Street: 7827 Sabal Lake Drive Permit Office: St. Lucie County City, State, Zip: Port St. Lucie, FL , 34950 Permit Number: Y U Owner: Melville Residence Jurisdiction: St. Lucie County W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and an gaps in the air barrier shall be sealed. Y 9 P shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between cover nlates and wall ceilino a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/9/2021 5:01 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1