HomeMy WebLinkAboutTruss® Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
MiTek
RE: 76952 - ERIK MELVILLE MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Customer Info: MICHAEL DIFRANCESSO Project Name: ERIK MELVILLE Model: Tampa, Fl- 33610-4115
Lot/Block: Subdivision:
Address: 7827 SABAL LAKE DR
City: PORT ST LUCIE State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License M
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.3
Wind Code: ASCE 7-10 Wind Speed: 170 mph
Roof Load: 40.0 psf Floor Load: N/A psf
This package includes 106 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
No.
Seal#
Truss Name
Date
1
T21280384
A
9/11/20
15
T21280398
D
9/11/20
2
T21280385
Al
9/11/20
16
T21280399
D1
9/11/20
3
T21280386
A2
9/11/20
17
T21280400
D2
9/11120
4
T21280387
A4
9/11/20
18
T21280401
D3
9/11/20
5
T21280388
A5
9/11/20
19
T21280402
D4
9/11/20
6
T21280389
A6
9/11/20
20
T21280403
D5
9111/20
7
T21280390
A7
9/11/20
21
T21280404
D6
9/11/20
8
T21280391
A8
9/11/20
22
T21280405
D7
9/11/20
9
T21280392
ATA
9/11/20
23
T21280406
D8
9/11/20
10
T21280393
ATB
9/11/20
24
T21280407
D9
9/11/20
11
T21280394
ATC
9/11/20
25
T21280408
D9A
9/11/20
12
T21280395
ATD
9/11/20
26
T21280409
F
9/11/20
13
T21280396
C
9/11/20
27
T21280410
F1
9/11/20
14
T21280397
C1
9/11/20
28
T21280411
G
9/11/20
This item has been electronically signed and sealed by Magid, Michael, PE using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Magid, Michael
My license renewal date for the state of Florida is February 28, 2021.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
1%111111111..
�,,�'PeL S. M� --ee
No 53681
3 % STATE OF10
.:441`
110N A
11111
Michael S. Magid PE No.53681
69 rk �i�83610
September 11,2020
Magid, Michael 1 of 2
N81 a
MiTek a
RE: 76952 - ERIK MELVILLE
Site Information:
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
Customer Info: MICHAEL DIFRANCESSO Project Name: ERIK MELVILLE Model:
Lot/Block: Subdivision:
Address: 7827 SABAL LAKE DR
City: PORT ST LUCIE State: FL
No. Seal# Truss Name Date
29
T21280412
G1
9/11/20
30
T21280413
G2
9/11/20
31
T21280414
G3
9/11/20
32
T21280415
G4
9/11/20
33
T21280416
G5
9/11/20
34
T21280417
G6
9/11/20
35
T21280418
G7
9/11/20
36
T21280419
G8
9/11/20
37
T21280420
GEF
9/11/20
38
T21280421
GEG
9/11/20
39
T21280422
GEM
9/11/20
40
T21280423
GR7
9/11/20
41
T21280424
GRB
9/11/20
42
T21280425
GRC
9/11/20
43
T21280426
GRID
9/11/20
44
T21280427
GRE
9/11/20
45
T21280428
GRG
9/11/20
46
T21280429
GRK
9/11/20
47
T21280430
GIRL
9111/20
48
T21280431
J1
9/11/20
49
T21280432
J3
9/11/20
50
T21280433
J5
9/11/20
51
T21280434
J5A
9/11/20
52
T21280435
J7
9/11/20
53
T21280436
JA
9/11/20
54
T21280437
JB
9/11120
55
T21280438
JC
9/11/20
56
T21280439
JD
9/11/20
57
T21280440
JE
9/11/20
58
T21280441
K
9/11/20
59
T21280442
K1
9/11/20
60
T21280443
K2
9/11/20
61
T21280444
K3
9/11/20
62
T21280445
K4
9/11/20
63
T21280446
K5
9/11/20
64
T21280447
K6
9/11/20
65
T21280448
K7
9/11/20
66
T21280449
K8
9/11/20
67
T21280450
KJ3
9/11/20
68
T21280451
KJ5
9/11/20
69
T21280452
KJA
9/11/20
70
T21280453
KJA5
9/11/20
71
T21280454
L
9/11/20
72
T21280455
M
9/11/20
73
T21280456
MV2
9/11/20
74
T21280457
MV4
9/11/20
75
T21280458
MV6
9/11/20
76
T21280459
MV8
9/11/20
77
T21280460
MV9
9/11/20
78
T21280461
MV10
9/11/20
79
T21280462
MV11
9/11/20
80
T21280463
MV12
9/11/20
81
T21280464
MV14
9/11/20
82
T21280465
MVA
9/11/20
83
T21280466
PBA
9/11/20
B4
T21280467
PBB
9/11/20
85
T21280468
PBC
9/11/20
No. Seal# Truss Name Date
86
T21280469
PBD
9/11/20
87
T21280470
PBE
9/11/20
88
T21280471
PBF
9/11/20
89
T21280472
PBG
9/11/20
90
T21280473
PBH
9/11/20
91
T21280474
PBI
9/11/20
92
T21280475
PBJ
9/11/20
93
T21280476
PBK
9/11/20
94
T21280477
PBL
9/11/20
95
T21280478
PBM
9/11/20
96
T21280479
PBN
9/11/20
97
T21280480
PBO
9/11/20
98
T21280481
SGEA
9/11/20
99
T21280482
SGEL
9/11/20
100
T21280483
V4
9/11/20
101
T21280484
V8
9/11/20
102
T21280485
V12
9/11/20
103
T21280486
V16
9/11/20
104
T21280487
V20
9/11/20
105
T21280488
V24
9/11/20
106
T21280489
V28
9/11/20
2of2
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280384
76952
A
ROOF SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:37 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-2ftGje5CG7CnY3gPid_dgX1 htaDZ39EVg_gHSsyegpm
-2-6-0 Orb-$ 4-2-12 10-6-0 17-0-0 23-0-0 29-9-0 33-3-14 34-0-p 36-6-0
2 6-0 0=8-2 3-6-10 6-3-4 6 6-0 6 6-0 6-3-4 3-6-10 0 8- 2-61
5x8 MT18HS =
6.00 12
5x10
. 5x10 zz� 13
20 4x12
4x12
10-6-0
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TPI2014
LUMBER -
TOP CHORD
2x6 SP 240OF 2.0E
BOT CHORD
2x6 SP No.2
WEBS
2x4 SP No.3
OTHERS
2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (size) 2=0-7-10, 10=0-7-10
Max Horz 2=-440(LC 10)
Max Uplift 2=-1848(LC 12), 10=-1848(LC 12)
Max Grav 2=1588(LC 1). 10=1588(LC 1)
Scale=1:72.2
CSI.
DEFL.
in (loc) Udell Ud
PLATES GRIP
TC 0.41
Vert(LL)
0.59 15-16 >691 240
MT20 244/190
BC 0.65
Vert(CT) -0.32 16-17 >999 240
MT18HS 244/190
WB 0.94
Horz(CT) -0.35 10 n/a n/a
Matrix -MS
Weight: 265 lb FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-6-5 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 2-3-7 oc bracing. Except:
3-0-0 oc bracing: 2-19
3-1-0 oc bracing: 10-12
WEBS
1 Row at midpt 6-16, 9-15, 3-17
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2550/5946, 3-5=-3404/8122, 5-6=-3036/6882, 6-7=3036/6846, 7-9=-3404/8168,
9-10=-2550/5945
BOT CHORD 2-19=-5013/2217, 17-19=-5129/2344, 16-17=-6771/3175, 15-16=-6864/3175,
12-15=-5219/2344, 10-12=-5099/2217
WEBS 6-16=-5662/2257, 7-16=-500/1441,7-15=-433/62,9-15=-19391786, 5-16=-500/1472,
5-17=-452/62,3-17=-1991/786,3-19=-639/1189,9-12=-639/1196
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=34ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-7-5, Interior(1) 0-7-5 to 17-0-0, Exterior(2) 17-0-0 to
20-4-13, Interior(1) 20-4-13 to 36-7-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1848 lb uplift at joint 2 and 1848 lb uplift
at joint 10.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Veritydesign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not Ie�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall HV
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUiP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke Fast Blvd.
Safety lnfornradon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280385
76952
Al
ROOF SPECIAL
3
1
Job Reference (optional)
Chambers I fuss, Inc., port f lerce, hL 8.33U s Jul ZZ ZUZU Mi IeK Inoustrles, Inc. I-n 5ep 11 14:18:a8 ZUZU Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-XsRew_6g1 JKe9DPbGLVsDlasfzZgocGfvePq_lyegpl
0 8-2 4-2-12 10-6-0 17-0-0 23-6-0 29-9 4 33-3-14 3 -0 36 6-0
0-8- 3 6-10 6-3-0 6 6-0 6-6.0 6-3-4 3-6-10 0-8- 2-6-0
5x8 MT18HS = Scale=1:71.2
6.00 12 5
3x4 -5�- P7 28 3x4
7x8 MT18HS WB i
7x8 MT18HS WB
4 6
3 7
3x5 3x5
2 15 8
26 7x8 =
N
1 V
17 16 14 13
3x4 � 9
o
46 bb 4.00 12 4x6 zz 10IT
18 3x4 11
5x10 5x10
12
19 6xl2
6x12
17-0-0 23-6-0 33-3-14
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017lrP12014
CSI.
TC 0.41
BC 0.66
WB 0.95
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/defl Ud
0.60 15-16 >683 240
-0.32 15-16 >999 240
-0.36 9 n/a n/a
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 259 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP 240OF 2.0E
TOP CHORD Structural wood sheathing directly applied or 5-5-12 oc purlins.
BOT CHORD 2x6 SP No.2
BOT CHORD Rigid ceiling directly applied or 2-3-2 oc bracing. Except:
WEBS 2x4 SP No.3
3-1-0 oc bracing: 1-18, 9-11
OTHERS 2x4 SP No.3
WEBS
1 Row at midpt 5-15, 2-16, 8-14
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (size) 1=0-7-10, 9=0-7-10
Max Horz 1=-427(LC 10)
Max Uplift 1=-1603(LC 12), 9=-1859(LC 12)
Max Grav 1=1426(LC 1), 9=1594(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2639/6156, 2-4=-3466/8295, 4-5=3061/6978, 5-6=-3062/6944, 6-8=3424/8246,
8-9=-2563/5992
BOT CHORD 1-18=-5270/2307, 16-18=-5398/2439, 15-16=-6929/3217, 14-15=-6937/3195,
11-14=-5260/2356,9-11=-5140/2228
WEBS 5-15=-5745/2279, 6-15=-498/1423, 6-14=-427/61, 4-15=-516/1487, 4-16=-470/67,
2-18=-644/1223, 8-11=-642/1210, 2-16=-1814/735, 8-14=-1946/794
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=34ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2) 0-0-0 to 3-4-13, Intedor(1) 3-4-13 to 17-0-0, Exterior(2) 17-0-0
to 204-13, Interior(1) 204-13 to 36-74 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
This item has been
shown; Lumber DOL=1.60 plate grip DOL=1.60
electronically signed and
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Magid, Michael, PE
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
Printed Copies of this
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1603 lb uplift at joint 1 and 1859 lb uplift
document are not considered
at joint 9.
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPl1 Quality CriteNa, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Jab
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280386
76952
A2
ROOF SPECIAL
6
1
Job Reference (optional)
Chambers Truss, Inc., Fart Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:40 2020 Page 1
ID:mis7T WUG3iZ7eEyY9QLybykl5J-TEZOLg85ZwaMPXZzOIXKIAfC8nErGVXxMyux3Byegpj
8- 4-2-12 10-6-0 17-M 23-M 29.9�4 33.3.14 0
-8- 3.6-10 6-3-0 6-6.0 6-6-0 6-34 3-6-10 -8-
3
5x8 MT18HS =
6.00 12
bx1U Y
5x10 zz� 11
18 4x12
4x12 i 34-0-0
q_e-2 10_6-0 17-0-0 23-6-0 29-9-4 33-3-14 33�11-10
49-2 9.9.14 6-0-0 6.6-0 6.3.4 3.6.10 7-1
LOADING (psf)
SPACING-
2-0-0
CS1.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.41
TCDL
10.0
Lumber DOL
1.25
BC 0.68
BCLL
0.0
Rep Stress Incr
YES
WB 0.96
BCDL
10.0
Code FBC2017ITP12014
Matrix -MS
Io
DEFL. In (loc) I/dell L/d PLATES GRIP
Vert(LL) 0.61 14-15 >674 240 MT20 244/190
Vert(CT) -0.32 14-15 >999 240 MT18HS 244/190
Horz(CT) -0.36 9 n/a n/a
LUMBER- BRACING -
TOP CHORD 2x6 SP 240OF 2.0E TOP CHORD
BOT CHORD 2x6 SP No.2 BOT CHORD
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3 WEBS
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (size) 1=0-7-10, 9=0-7-10
Max Horz 1=-381(LC 10)
Max Uplift 1=-1614(LC 12), 9=-1614(LC 12)
Max Grav 1=1432(LC 1), 9=1432(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2651/6167, 2-4=-3487/8362, 4-5=-3087/7078, 5-6=-3087/7078, 6-8=-3487/8362,
8-9=-2651/6167
BOT CHORD 1-17=-5351/2318, 15-17=-5483/2450, 14-15=-7096/3236, 13-14=-7096/3236,
10-1 3=-5483/2450, 9-1 0=-5351/2318
WEBS 5-14=-5833/2301,6-14=-514/1413, 6-13=-451/66,8-13=-1939/743. 4-14=-514/1413,
4-15=451/66,2-15=-1939/743,2-17=-648/1249,8-10=-648/1249
Scale=1:65.9
Weight: 252 lb FT = 20%
Structural wood sheathing directly applied or 5-5-9 oc purlins.
Rigid ceiling directly applied or 2-2-9 oc bracing. Except:
3-1-0 oc bracing: 1-17, 9-10
1 Row at micipt 5-14, 8-13, 2-15
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=34ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-4-13, Interior(1) 3-4-13 to 17-0-0, Exterior(2)17-0-0
to 204-13, Interior(1) 20-4-13 to 34-0-0 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1614 lb uplift at joint 1 and 1614 lb uplift
at joint 9.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date;
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
��AA
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
-VY�
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPIf Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
T21280387
76952
A4
ROOF SPECIAL
�Qty
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:42 2020 Page 1
ID:mis1T W UG31Z7eEyY9QLybykl5J-PdhgmM9L5Xg3eriMVAZoNbkVgay9kPiEgGN273yegph
0-�-12 4-2.6 10-CA 18-1-2 23 6 0 29-8-14 33-3-8 33r11r4
0- -1 3-6-10 6-3 10 7-7-2 '4 4 6-2-14 3-6-10 0-/�12
4x5 = 5x12 MT18HS =
7x8 = 6x8 =
242 3 4 25 26 5
6.00 112
Scale = 1:66.3
,9 4x12
33-3-8
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017frP12014
CSI.
TC 0.59
BC 0.56
WB 0.98
Matrix -MS
DEFL. in (loc) I/defi Ud
Vert(LL) -0.13 15 >999 360
Vert(CT) -0.26 15 >999 240
Horz(CT) -0.28 9 n/a file
Wind(LL) 0.46 15-16 >879 240
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 289 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP 240OF 2.OE *Except*
TOP CHORD
Structural wood sheathing directly applied or 5-6-0 oc puffins,
1-3: 2x6 SP No.2
except end verticals.
BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 2-7-4 oc bracing. Except:
WEBS 2x4 SP No.3 'Except'
3-1-0 oc bracing: 9-10
2-16,2-20: 2x4 SP M 30
WEBS
1 Row at midpt 1-20, 4-15, 8-13, 2-16, 2-20
OTHERS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
REACTIONS. (size) 20=0-7-10, 9=0-7-10
Max Horz 20=-511(LC 12)
Max Uplift 20=-1667(LC 12), 9=-1541(LC 12)
Max Grav 20=1424(LC 1),9=1423(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=1686/4142, 4-5=-2940/6901, 5-6=-3134/7095, 6-8=-3436/8102, 8-9=2621/5974
BOT CHORD 18-20=-988/641, 16-18=-910/694, 15-16=-3236/1789, 14-15=-5540/2864,
13-14=-6908/3187, 10-13=-529212415, 9-10=-5174/2289
WEBS 4-16=-1213/2141,4-15=-3221/1464,5-15=-1476f118,5-14=-1326/340,6-14=-332/1177,
6-13=-379/33, 8-13=-1853/725, 2-18=-286/174, 2-16=-3572/1450, 2-20=-1435/3506,
8-10=-638/1179
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=34ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-6-8, Interior(1) 3-6-8 to 18-1-2, Exterior(2) 18-1-2
This item has been
to 21-5-14, Interior(1) 21-5-14 to 33-11-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
electronically signed and
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
sealed by Magid, Michael, PE
3) All plates are MT20 plates unless otherwise indicated,
using a Digital Signature.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Printed copies Of this
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
document are not considered
will fit between the bottom chord and any other members.
signed and sealed and the
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1667 lb uplift at joint 20 and 1541 lb
uplift at joint 9.
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Ar
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Marla, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
FA5s
T21280388
76952
Piggyback Base
1
1
Job Reference o tlonal
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:48 2020 Page 1
I D:mis?T W UG3iZ?eE,yY9 QLybykl5J-En2QOPE6 h N bDM mAWsRg Cds_ZO?Op89L7CCgMLjyeg pb
3-10 3 10-6-0 18-7-2 23 6-0 29-0-1 33-2-4
3 10, 6-7-13 8-1-2 4-10-14 5 10-1 3-10-3
Scale = 1:58.8
3x5 =
3x4 II 4x8 = 4x6 =
1 226 3 4 27 28 5 5x8 = 6.00 12
20 VERTICAL SUPPORT OF FREE END ~n 12
OF CHORD IS REQUIRED AT EACH END 45 11
OF TRUSS, TYPICAL.
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TP12014
CSI.
TC 0.48
BC 0.48
WB 0.78
Matrix -MS
DEFL. in (loc) I/deft Lid
Vert(LL) -0.16 16 >999 360
Vert(CT) -0.33 16-17 >999 240
Horz(CT) 0.21 10 n/a n/a
Wind(LL) 0.22 16 >999 240
PLATES GRIP
MT20 244/190
Weight: 247 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-8-9 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-7-12 oc bracing.
SLIDER Right 2x4 SP No.3 -H 2-6-0
WEBS
1 Row at micipt 1-21, 2-17, 2-21
REACTIONS. (size) 21=Mechanical, 10=Mechanical
Max Harz 21=-471(LC 12)
Max Uplift 21=-862(LC 12), 10=-744(LC 12)
Max Grav 21=1394(LC 1), 10=1409(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1776/1248, 4-5=-3058/1961, 5-6=2999/1934, 6-8=3152/2071, 8-10=-2293/1502
BOT CHORD 19-21=-17/632, 17-19=-24/685, 16-17=759/1884, 15-16=-1369/2765, 14-15=-1721/2940,
11-14=-1269/2076, 10-11=-1202/1959
WEBS 2-17=-1014/1527, 4-17=-12391947, 4-16=-825/1483, 5-16=-262/888, 5-15=-208/272,
6-15=-307/355, 8-14=4371823, 8-11 =-542/471, 2-21 =-1 40711096
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=33ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-5-9, Interior(1) 3-5-9 to 18-7-2, Exterior(2) 18-7-2
to 21-10-15, Intedor(1) 21-10-15 to 33-24 zone;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members,
electronically Signed and
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 862 lb uplift at joint 21 and 744 lb uplift
sealed by Magid, Michael, PE
at joint 10.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
I
s always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280389
76952
A6
Piggyback Base
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:51 2020 Page 1
ID:m Is?T W UG3iZ?eEyY9QLybykl5J-eMjYfRG_zlzoDDu5XZEvFUc?5 D43LUsZuA3Oy2yeg pY
3-10-3 10.6-0 18-7.2 9-7-2 23-6.0 29-0-1 31-7-2 33.2-0
3-10-3 6-7-13 8.1-2 -0-0 3.10.14 5-10-1 2-3-1 1-7-2
3x4 II
6x8 =
4x4 =
4x8 = 46 =
223 3 4 24
25
6.00 112
5x8 MT18HS
5x8 =
3x4 =
4x4 = 4x6 =
4x10 =
21 13
33-2-4
0-fi 10-6-0 16-7-2 16-7-2 i9-7-2 23-6-0 31-7-2 r32.11-0
0• 10.2-12 6-1-2 2-0-0 1-0-0 3-1.14 6-1-2 1-3-14
Scale = 1:59.7
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.75
BC 0.38
WB 0.93
Matrix -MS
DEFL. in (loc) Udefl Ud
Vert(LL) -0.19 17 >999 360
Vert(CT) -0.39 17-18 >999 240
Horz(CT) 0.24 11 n/a n/a
Wind(LL) 0.30 17 >999 240
PLATES GRIP
MT20 244/190
MT18HS 2441190
Weight: 275 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-11-8 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-1-14 oc bracing.
WEBS
1 Row at micipt 1-22, 2-18, 4-17, 8-15, 10-11, 8-12, 2-22
REACTIONS. (size) 22=Mechanical, 11=Mechanical
Max Horz 22=-80(LC 12)
Max Uplift 22=-817(LC 12), 11=-784(LC 12)
Max Grav 22=1387(LC 1), 11=1380(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1748/1323, 4-5=-3083/2300, 5-6=-2489/1871, 6-7=-2687/2031, 7-8=1780/1373,
8-9=-549/465,9-10=592/463, 10-11 =-1 338/1027
BOT CHORD 20-22=-341/607, 18-20=-366/659, 17-18=-1291/1854, 16-17=-2043/2804,
15-16=-137611886,12-15=478/660
WEBS 2-18=-1148/1489,4-18=-1205/1066,4-17=-1130/1646,5-17=-529/872,5-16=-895/717,
7-16=-814/1120,7-15=-1346/1097,8-15=-1160/1588,8-12=-1151/996,10-12=-885/1230,
2-22=-1408/1044
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=33ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-5-9, InteNor(1) 3-5-9 to 18-7-2, Exterior(2) 18-7-2
to 19-7-2, Interior(1) 19-7-2 to 31-7-2, Exterior(2) 31-7-2 to 33-0-8 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are MT20 plates unless otherwise indicated.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically Signed and
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
led b Magid, Michael, PE
seaY 9
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections,
using a Digital Signature.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 817 lb uplift at joint 22 and 784 lb uplift
Printed copies of this
at joint 11.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Qualify Criteria, DSB-89 and BCS/Building Component 6904 Parke East Blvd.
Safety
Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280390
76952
A7
Piggyback Base
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:52 2020 Page 1
ID:m I s?T W UG3iZ?eEyY9 QLybykl5J-6YHwsm Hckc5frNTH5Hl8ni9 DEcN F4wH i7goa U Uyeg pX
3-10-3 7-10-7 15.55 6.7;2 23-0-4 30-7-2 33.24
3-10-3 4-04 7-6-15 6-5-2 7-6-15 22
3x6 II
NI
3x8 = 06 = 30 II
5x8 =
221 3 22 23 4 5 24 6 25 7
19 VERTICAL SUPPORT OF FREE END
OF CHORD IS REQUIRED AT EACH END
OF TRUSS, TYPICAL.
6.00 191cale=1:58.2
0- 7-10-7 16-7-2
-0
234
30-7-2 -11-0 2
32 33
0- 7-7-3 85-12
6-12
7-6-15 2-3-14 0- 4
Plate Offsets (X,Y)—
[3:0-3.8,0-1-81,[7:0-5-8,0-2-121,[18:0-2-4,0-2-41
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. In
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(LL) -0.21
15-17 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.45
Vert(CT) -0.61
15-17 >781 240
BCLL 0.0
Rep Stress Incr YES
WB 0.98
Horz(CT) 0.22
9 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.29
15 >999 240
Weight: 275 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-7-14 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied
or 6-6-6 oc bracing.
WEBS
1 Row at micipt
1-20, 3-15, 6-15, 7-14, 7-10, 8-9, 2-18,
1-18, 2-17
REACTIONS. (size) • 20=Mechanical, 9=Mechanical
Max Horz 20=-80(LC 12)
Max Uplift 20=-819(LC 12), 9=-782(LC 12)
Max Grav 20=1380(LC 1), 9=1387(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-20=-1326/1037, 1-2=-509/375, 2-3=-12911951, 3-5=-3151/2317, 5-6=-3151/2317,
6-7=1691/1320, 7-8=506/383, 8-9=-1346/980
BOT CHORD 17-18=-329/623, 15-17=-887/1385, 14-15=-1274/1802, 12-14=-301/458, 10-12=-283/417
WEBS 3-17=-1239/1069, 3-15=-1477/2008, 5-15=430/478, 6-15=-1147/1668,
6-14=-1257/1044,
7-14=-1150/1593,7-10=-1055/929,8-10=-804/1172,2-18=-1295/1033,1-18=-966/1308,
2-17=-1003/1358
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=33ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-5-9, Interior(1) 3-5-9 to 30-7-2, Exterior(2) 30-7-2
to 33-0-8 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are 44 MT20 unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
electronically signed and
will fit between the bottom chord and any other members.
led b Magid, Michael, PE
Seay g
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 819 lb uplift at joint 20 and 782 lb uplift
using a Digital Signature.
at joint 9.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M[T�k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280391
76952
A8
Piggyback Base
6
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:53 2020 Page 1
I D: ml s7T W U G3iZ7eEyY9QLybykl5J-akrJ461 EVwDVSX2Te—GN Kvh M40klp Q9sMUY70xyegpW
i 3.10-3 7-11-2 15-5-13 16.7.2 23.0-7 30-7-2 33-2-0
3-10-3 15 7.6.11 1-1-5 6-5-5 7-6-11 2-7-2
Scale=1:61.7
6x8 =
3x4 II 4x6 = 4x4 =
6.00 12 3 22 23 24 4 5 25 6 26
4x4
3x6 11
5x8 =
7
19 5x12 � 4x4 =
= 11
VERTICAL SUPPORT OF FREE END 44
OF CHORD IS REQUIRED AT EACH END
OF TRUSS, TYPICAL.
0• 7-11-2 16-7-2 23-0-7
U0-7-7-14
30-7-2 32-11-0 33
8.8-0 6-5.5
7-6-11 2314 0. -4
Plate Offsets (X,Y)—
[3:0-64,0-3-01,[7:0-5-8,0-2-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. In
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.65
Vert(LL) -0.19
15-17 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.43
Vert(CT) -0.45
15-17 >871 240
BCLL 0.0
Rep Stress Incr YES
WB 0.81
Horz(CT) 0.21
9 We n/a
BCDL 10.0
Code FBC2017[TP12014
Matrix -MS
Wind(LL) 0.28
15 >999 240
Weight: 262 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 3-4-1 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 6-2-3 oc bracing.
WEBS
1 Row at midpt 3-15, 6-15, 7-14, 7-10, 8-9
REACTIONS. (size) 20=Mechanical, 9=Mechanical
Max Horz 20=172(LC 12)
Max Uplift 20=-774(LC 12), 9=-827(LC 12)
Max Grav 20=1380(LC 1), 9=1387(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-854/644, 2-3=-148811271, 3-4=-3161/2679, 4-6=-3161/2679, 6-7=-1685/1460,
7-8=-505/415, 1-20=1326/1013, 8-9=-1345/1065
BOT CHORD 17-18=-826/894,15-17=-1174/1374,14-15=-1422/1796,12-14=-330/458,10-12=-311/417
WEBS 3-17=-528/495, 3-15=-1573/2032, 4-15=461/529, 6-15=-1398/1685, 6-14=-125411170,
7-14=-1293/1589,7-10=-1056/1013,8-10=-882/1172,1-18=-796/1113,2-18=-1014/926,
2-17=484/722
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=33ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-5-9, Interior(1) 3-5-9 to 7-11-2, Exterior(2) 7-11-2
to 12-7-7, Interior(1) 12-7-7 to 30-7-2, Exterior(2) 30-7-2 to 33-0-8 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
electronically signed and
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
Sealed b Magid, Michael, PE
y 9
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 774 Ib uplift at joint 20 and 827 lb uplift
using a Digital Signature.
at joint 9.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verity deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19I2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Iva I'
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280392
76952
ATA
ATTIC
2
1
Jab Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:55 2020 Page 1
ID:mis?TWUG3IZ?eE,yY9QLybykl5J-X7z3UoJV1XTDigCsmPlrPKnjl gNBHNG9po 1 E5pyegpU
-2-6-0 5 0-0 7-10 4 9-8-0 ,11-0-5 13-0-0 14-11-11 16 4-0 18-1-12 21-0-0 26-0-0 28-6-0
2-6-0 ' 5 0-0 2-10.4 1-9-12 ' 1.4-5 1-11-11 1-11-11 1 4-5 1-9-12 2-10-4 5-0-0 2-6-0
3
5x6 =
6.00 12 7 26
4x5 = ax0,— 3x5 = ax0 —
7-10.4 13.0-0 18-1-12 26-0-0
Scale=1:50.4
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Cade FBC2017rrPI2014
CSI.
TC 0.62
BC 0.63
WB 0.58
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft Ud
-0.38 14-16 >820 360
-0.59 14-16 >526 240
0.04 12 n/a n/a
0.16 14-16 >999 240
PLATES
MT20
MT18HS
Weight: 172 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP 240OF 2.0E *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-8-11 cc purlins.
1-4,10-13: 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2x6 SP 240OF 2.0E
JOINTS
1 Brace at Jt(s): 17
WEBS 2x4 SP Nc.3
REACTIONS. (size) 2=0-7-10, 12=0-7-10
Max Horz 2=-328(LC 10)
Max Uplift 2=-721(LC 12), 12=-721(LC 12)
Max Grav 2=1632(LC 18), 12=1632(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=2752/841, 3-5=-2474/699, 5-6=-2021/694, 6-7=-121/465, 7-8=-121/465,
8-9=-2021/694,9-11=-2474/699,11-12=-2752/840
BOTCHORD 2-16=-492/2616, 14-16=-272/2151, 12-14=-583/2400
WEBS 9-14=-137/917. 5-16=-137/917, 6-17=-2568/857, 8-17=-2568/857, 3-16=-610/408,
11-14=-612/407
I9
a
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf: BCDL=3.Opsf; h=20ft; B=45ft; L=26ft; save=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-7-5, Interior(1) 0-7-5 to 13-0-0, Exterior(2) 13-0-0 to
16-0-0, Interior(1) 16-0-0 to 28-7-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) 200.0111D AC unit load placed on the top chord, 13-0-0 from left end, supported at two points, 4-0-0 apart.
4) All plates are MT20 plates unless otherwise indicated.
This item has been
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically Signed and
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
b Magid, Michael, PE
Will fit between the bottom chord and any other members.
sealed Y 9
7) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-17. 8-17
using .a Digital Signature.
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 14-16
Printed copies of this
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 721 lb uplift at joint 2 and 721 lb uplift at
document are not considered
joint 12.
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall�a
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280393
76952
ATB
ATTIC
7
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:56 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-?JXRi8K7orb4J_n2K6g4yYJujEjROrtl2SmndGyegpT
21-0 5-0-0 7-102-4 9-8-0 11-0-5 13-0-0 14-11-11 164-0 18; 2 21-0-0 25-7-8
2-6-0 5-0-0 2-10-4 1-9.12 1-4-5 1-11-11 1-11-11 1-4-5 1-9.12 2-10 4 4-7-8
Scale=1:50.6
5x6 =
6.00 12 7 24
�d
4x5 = 3x5 = —"'— "" ""' 3x4 = 5x6 =
13-0-0 18-1-12
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.63
BC 0.62
WB 0.56
Matrix -MS
DEFL,
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/defi Ud
-0.38 12-14 >819 360
-0.58 12-14 >528 240
0.04 11 n/a n/a
0.16 12-14 >999 240
PLATES
MT20
MT18HS
Weight: 165 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP 240OF 2.0E *Except*
TOP CHORD
Structural wood sheathing directly applied or 3-8-15 oc purlins.
1-4: 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2x6 SP 240OF 2.0E
JOINTS
1 Brace at Jt(s): 15
WEBS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
REACTIONS. (size) 11=0-5-8, 2=0-7-10
Max Horz 2=313(LC 11)
Max Uplift 11=-461(LC 12), 2=-728(LC 12)
Max Grav 11=1469(LC 19), 2=1614(LC 18)
FORCES. (Ib) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2715/887, 3-5=-2431/746, 5-6=-19791704, 6-7=-125/450, 7-8=-130/443,
8-9=-1987/736, 9-10=-2401/795, 10-11=-2634/948
BOT CHORD 2-14=-705/2544, 12-14=-411/2067, 11-12=-729/2250
WEBS 5-14=-134/915, 9-12=172/839, 6-15=2503/934, 8-15=-2503/934, 3-14=-624/386,
10-12=489/417
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=26ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-7-5, Interior(1) 0-7-5 to 13-0-0, Exterior(2) 13-0-0 to
16-0-0, Interier(1)16-0-0 to 25-7-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
This item has been
3) 200.01b AC unit load placed on the top chord, 13-0-0 from left end, supported at two points, 4-0-0 apart.
electronically signed and
y SI g
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Magid, Michael, PE
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
Printed copies Of this
7) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-15, 8-15
document are not considered
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-14
signed and sealed and the
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 461 lb uplift at joint 11 and 728 lb uplift
at joint 2.
signature must be verified
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
On any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall�a
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
T21260394
76952
ATC
ATTIC
�Qty
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:18:59 2020 Page 1
I D:mis7TWUG3iZ7eE,yY9QLybykl5J-PuCaKAM75mzfASWd7FNnZAxMJRh5D7JkkP7REayegpQ
2 6 0 5-0-0 7-10- 9-8-0 11-0-5 14-8-0 18-1-12 25-7-8
2-6-0 5 0-0 T10 4 1-9-12 1-4-5 3-7-11 3-5-12 7-5-12
3
6x8 =
3x4 11
7 20 21 22 8 23 24
Scale=1:49.8
4x6 =
4x10 = 3x4 = '"" - 7x8 = ix6
25-7-8
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171rP12014
CSI.
TC 0.80
BC 0.82
WB 0.90
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/defl L/d
-0.61 11-13 >497 360
-1.17 11-13 >262 240
0.03 2 n/a n/a
0.65 11-13 >472 240
PLATES GRIP
MT20 244/190
Weight: 191 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2 *Except*
TOP CHORD Structural wood sheathing directly applied or 2-10-13 oc purlins,
4-7: 2x6 SP 240OF 2.0E
except end verticals.
BOT CHORD 2x6 SP 240OF 2.0E
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3'Excepr
WEBS
1 Row at midpt 9-10, 9-11
8-11: 2x4 SP M 30
JOINTS
1 Brace at Jt(s): 14, 15
REACTIONS. (size) 10=0-5-8, 2=0-7-10
Max Horz 2=601(LC 12)
Max Uplift 10=-547(LC 9), 2=-654(LC 12)
Max Grav 10=1593(LC 18), 2=1690(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2639/664, 3-5=-2149/455, 5-6=-1756/444, 6-7=-1311/369, 7-8=-1260/475,
8-9=-1557/593, 9-10=-1674/800
BOT CHORD 2-13=-1067/2458, 11-13=-639/1672
WEBS 5-13=-59/771, 11-14=-627/549, 8-14=-628/565,9-11=-848/2244,6-15=-420/163,
14-15=-412/164,3-13=-1030/562
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=26ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7.4 to 0-7-5, Interior(1) 0-7-5 to 14-8-0, Exterior(2)14-8-0 to
18-10-15, Interior(1) 18-10-15 to 25-5-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 200.0I15 AC unit load placed on the top chord, 13-0-0 from left end, supported at two points, 4-0-0 apart.
This item has been
4) Provide adequate drainage to prevent water ponding.
electronically Signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This has been designed
sealed by Magid, Michael, PE
truss for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
using a Digital Signature.
7) Ceiling dead load (5.0 psf) on member(s). 5-6, 6-15, 14-15
Printed copies of this
8) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 11-13
document are not considered
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 547 lb uplift atjoint 10 and 654 lb uplift
signed and sealed and the
at joint 2.
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Signature must be Verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall �-
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIf Quality Criteria, DSB-89 and SCSI Bullding Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280395
76952
ATD
ATTIC
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:00 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-t4myYVNds35Woc4pZyuO6OUYkr13yapuz3k?ml yegpP
5-0-0 7-10-4 9-8-0 11-0-5 14-0.0 1&8-0 16- 12 25-7-8
5.0.0 2-10-4 1-9-12 1-4-5 2-11-11 2-8-0 0-1- 2 8-9-12
7x8 MT18HS =
6.00 12
21 22 23
4x5 =
12 10 9
4x12 = 3x41 — 8-8-0 1 3x10
7x8 =
Scale =1:57A
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.76
BC 0.77
WB 0.88
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl Ud
-0.64 10-12 >478 360
-1.26 10-12 >242 240
0.03 1 n/a n/a
0.81 12 >377 240
PLATES
MT20
MT18HS
Weight: 192 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2 *Except*
TOP CHORD
Structural wood sheathing directly applied or 4-3-11 oc purling,
1-5: 2x6 SP 240OF 2.0E
except end verticals.
BOT CHORD 2x6 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at micipt 8-9. 8-10
7-10: 2x4 SP M 30
JOINTS
1 Brace at Jt(s): 13, 14
REACTIONS. (size) 9=0-5-8, 1=0-7-10
Max Horz 1=538(LC 12)
Max Uplift 9=-574(LC 12), 1=-390(LC 12)
Max Grav 9=1578(LC 18), 1=1517(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2584/670, 2-3=-2033/401, 3-4=-1692/370, 4-6=-1873/563, 6-7=-13571470,
7-8=-1449/586, 8-9=-15761845
BOT CHORD 1-12=-1147/2453, 10-12=-633/1567
WEBS 3-12=-142/598, 10-13=-459/484, 7-13=-152/351,8-10=-815/2036,4-14=-147/296,
13-14=-147/296, 2-12=-1162/712,6-13=-724/307
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=26ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Intedor(1) 3-0-0 to 16-8-0, Exterior(2) 16-8-0 to
20-10-15, Interior(1) 20-10-15 to 25-5-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 200.01b AC unit load placed on the top chord, 13-0-0 from left end, supported at two points, 4-0-0 apart.
This item has been
4) Provide adequate drainage to prevent water ponding.
electronically Signed and
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Magid, Michael, PE
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Printed copies of this
8) Ceiling dead load (5.0 psf) on member(s). 3-4, 4-14, 13-14
document are not considered
9) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 10-12
SI g
signed and sealed and the
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 574 lb uplift at joint 9 and 390 lb uplift
at joint 1.
signature must be verified
11) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
on any electronic Copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev, 5/1912020 BEFORE USE.
Design valid for use only with MMek01 connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280396
76952
C
Monopitch
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:01 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-LHKKIrOGdNENOmfO6gPFfbl ofFUeh9u 1 BjUYITyegpO
8-1-7 16-3-2
8-1-7 8-1-11
Scale: 1r4-=1'
.-
1 5
3x4 =
2x3 II 3x6 = 6x8 =
'
8-1-7
8-1-7
16-3-2
8-1-11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.42
Vert(LL) -0.09
5-7 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.18
5-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.38
Horz(CT) -0.02
5 n/a n/a
BCDL 10.0
Code FBC2017/ P12014
Matrix -MS
Wind(LL) 0.07
7-10 >999 240
Weight: 98 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 8-7-5 oc bracing.
WEBS
1 Row at micipt 4-5. 2-5
REACTIONS. (size) 1=0-7-10, 5=0-5-8
Max Horz 1=518(LC 12)
Max Uplift 1=-264(LC 12), 5=-540(LC 12)
Max Gram 1=646(LC 17), 5=706(LC 17)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less
except when shown.
TOP CHORD 1-2=-901/302, 4-5=-210/318
BOT CHORD 1-7=-689/802, 5-7=-689/802
WEBS 2-7=0/360, 2-5=-902/779
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 16-1-6 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 lb uplift at joint 1 and 540 lb uplift at
joint 5.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
■ii��•���
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply=ptional)
T21 27
76952
C1
Monopitch
2
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:02 2020 Page 1
ID:mis7TWUG3iZ7eE,yY9QLybykl5J-gTuiyBPuOhME2vECgNwUBpZ_erSQUIBQND5r yegpN
6-11-3 13-10-10
6-11-3 6-11-7
Scale = 1:41.9
i
3x4 = 2x3 II 6x8 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.32
Vert(LL)
-0.05
4-5
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.27
Vert(CT)
-0.10
4-5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.85
Horz(CT)
-0.01
4
n/a
n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Wind(LL)
0.04
5-8
>999
240
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (size) 1=0-7-10, 4=0-5-8
Max Horz 1=442(LC 12)
Max Uplift 1=-224(LC 12), 4=-462(LC 12)
Max Grav 1=551(LC 17), 4=602(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-757/267, 34=180/293
BOT CHORD 1-5=-604/672, 4-5=-604/672
WEBS 2-5=0/305, 24=-758/685
PLATES GRIP
MT20 244/190
Weight: 84 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 9-3-4 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3,Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-8-14 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 224 lb uplift at joint 1 and 462 lb uplift at
joint 4.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall �-
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSV7P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280398
76952
D
HALF HIP
1
1
Job Reference o floral
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:03 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-IfS5AXPW9_U5f3pOE5Sjk067W2A99zBKfl zfNMyegpM
2-6 0 7-0-0 11-7-13 19-7-13 27.6-0 35.6-0
2 6 0 7-0-0 4-7-13 8-0-0 7-10.4 8-0-0
S.00 112
Scale: 3/16'=l'
5x8 = 3x4 11 4x4 = 4x8 = 4x4 = 5x6 =
321 422 23 24 5 6 25 7 26 8
6x8 = 3x6 I
4x6 = 3x4 II 3x6 = 3x4 = 3x6 = 3x5 =
19-7-13
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TP12014
CSI.
TIC 0.46
BC 0.36
WB 0.71
Matrix -MS
DEFL. in (loc) Well L/d
Vert(LL) -0.09 9-10 >999 360
Vert(CT) -0.19 9-10 >999 240
Horz(CT) 0.02 9 n/a n/a
Wind(LL) 0.14 15-18 >974 240
PLATES GRIP
MT20 244/190
Weight: 216 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puriins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEDGE
WEBS
1 Row at midpt 5-13, 7-12, 8-10
Left: 2x4 SP No.3
REACTIONS. (size) 9=0-5-8, 24-7-10, 13=0-7-10
Max Horz 2=355(LC 12)
Max Uplift 9=-544(LC 9), 2=-643(LC 12), 13=-1374(LC 12)
Max Grav 9=838(LC 1), 2=415(LC 1), 13=1731(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-36/446, 3-4=-478/589, 4-5=-478/589, 5-7=-967/775, 7-8=-1200/935, 8-9=-767/695
BOT CHORD 2-15=-557/22, 13-15=-576/24, 12-13=775/967, 10-12=-935/1200
WEBS 3-15=-501/217, 3-13=-698/1187, 4-13=-438/494, 5-13=-1718/1271, 5-12=-38/396,
7-12=-261/221, 7-10=-398/495, 8-10=-1016/1297
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-11-6, Interior(1) 0-11-6 to 7-0-0, Exterior(2) 7-0-0 to
12-0-0, Interjor(1) 12-0.4 to 35-4-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
electronically signed and
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 544 lb uplift at joint 9, 643 lb uplift at
sealed by Magid, Michael, PE
joint 2 and 1374 lb uplift at joint 13.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 quality Criteria, DSB•89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280399
76952
D1
HALF HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:06 2020 Page 1
I D: m Is?T W UG3iZ?eEyY9 QLybykl5J-i E7DoZSORvsf WXYrvDTQMfkZyG9 CMLTmL?BJ_gyegpJ
2-6-0 _, 9-M 11-7-13 19-7-13 27-6-0 35-6-0
2 6 0 9-0-0 2-7-13 8-0-0 7-10-4 8-0-0
5x8 = 3x4 II
21 22
4x4 = 4x8 =
23 5 6
24
4x4 =
25
Scale: 3/16-=l'
5x6 =
3x6 = 6x8 = 3x4 = 3x6 = 3x4 = 3x6 II
4x6 = 3x4 II
11-7-13 35 19-7-13 27-6-0 -6-0
9-0-0 2-7-13 8-0-0 7-10.4 80-0
Plate Offsets (X,Y)—
[2:0-0-0,0-0-31,[3:0-54,0-3-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.71
Vert(LL) 0.37 15-18 >375 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.47
Vert(CT) -0.24 15-18 >577 240
BCLL 0.0
Rep Stress Incr YES
WB 0.61
Horz(CT) -0.03 2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 226 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
WEDGE WEBS
Left: 2x4 SP No.3
REACTIONS. (size) 9=0-5-8, 2=0-7-10, 13=0-7-10
Max Horz 2=419(LC 12)
Max Uplift 9=-597(LC 9), 2=-736(LC 12), 13=-1224(LC 12)
Max Grav 9=885(LC 1), 2=511(LC 1). 13=1589(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-138/532, 3-4=-53/342, 4-5=-53/342, 5-7=-923/914, 7-8=-1029/889, 8-9=-8151784
BOT CHORD 2-15=-681/126, 13-15=-7021128, 12-13=-914/923, 10-12=-889/1029
WEBS 3-15=-671/264, 3-13=-555/1139, 4-13=-330/387, 5-13=-1356/963, 5-12=0/360,
7-10=-448/590, 8-10=-102511180
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 7-5-2 oc bracing.
1 Row at midpt 5-13, 7-12, 8-10
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-11-6, Interior(1) 0-11-6 to 9-0-0, Extedor(2) 9-0-0 to
14-04, Interior(1) 14-0-4 to 3544 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 597 lb uplift at joint 9, 736 lb uplift at
joint 2 and 1224 lb uplift at joint 13.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYnPl1 quality criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
MELVILLET21280400
76952
D2
HALF HIP
1
1�.ERIIK
ob Reference o tional
Chambers I russ, Inc., Fort vierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:08 2020 Page 1
ID:mis?TWUG31Z7eEyY9QLybykl5J-edF_DFTf7X6NmgiM1 e1 uR4pyY3tRgBN3oJgQ2ZyegpH
2 00 5-7-10 11-0-0 19-2-9 27-3-7 35-6-0
2 6-0 5 7-10 5-4-6 8-2-9 8-0-13 8-2-9
3
Scale: 3/16"=l'
4x8 = 6x8 = 3x4 II 4x8 = 4x4 = 5x6 =
4 5 22 23 24 6 7 25 8 26 9.
45 =
3x4 II 3x6 =6x8 = 3x10 = 3x6 = 3x4 = 3x6
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.57
BC 0.36
WB 0.84
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefi L/d
-0.09 10-11 >999 360
-0.20 10-11 >999 240
-0.01 10 n/a n/a
0.08 14-16 >999 240
PLATES GRIP
MT20 244/190
Weight: 233 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at micipt 5-13. 8-13, 9-11
REACTIONS. (size) 10=0-5-8, 2=0-7-10, 14=0-7-10
Max Horz 2=483(LC 12)
Max Uplift 10=-537(LC 9), 2=-572(LC 12), 14=-1453(LC 12)
Max Grav 10=901(LC 18), 2=444(LC 1), 14=1689(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=195/392, 3-4=-526/433, 4-5=-375/328, 5-6=-675/401, 6-8=-675/401,
8-9=-847/593,
9-10=-791/670
BOT CHORD 2-16=-698/213, 14-16=-698/213, 13-14=-328/375, 11-13=-593/847
WEBS 3-16=-457/219, 3-14=-496/1127, 5-13=-938/1218, 6-13=-466/505, 8-11=-414/469,
9-11=-718/1019, 5-14=-1317/1298
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-11-6, Interior(1) 0-11-6 to 11-0-0, Exterior(2) 11-0-0
to 16-0-4, Interior(1) 16-0-4 to 35-4-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
electronically signed and
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 537 lb uplift at joint 10, 572 lb uplift at
sealed by Magid, Michael, PE
joint 2 and 1453 lb uplift at joint 14.
using a Digital Signature.
Printed copies of this
`
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Data:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
bat
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280401
76952
D3
HALF HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:12 2020 Page 1
I D: mis?T W U G3iZ?eE_rY9QLybykl5J-XOV U3 cW91 Icp ES?7G U6gbwyrg F4 m3TfjxedBKyegpD
2-61 1 7-0-0 11-7-13 13-0-0 20-6-9 27-11-7 35-6-0
2-6 0 7-0-0 4 7-13 1-4-3 7-6-9 7 4-13 7 6 9
5x8 =
6.00 12
3x8 11 6 24 2526
3x4 II 4x8 = 4x4 =
27
Scale: 3/16-=l'
5x6 =
P8 10
4x5 =
3x4 II 3x6 =6x8 = 3x4 II 3x8 = 3x5 = 3x6
3x6 =
20.6-9
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.43
BC 0.31
WB 0.58
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl L/d
-0.09 14-15 >999 360
-0.20 14-15 >999 240
0.03 11 n/a n/a
0.12 18-21 >999 240
PLATES GRIP
MT20 244/190
Weight: 249 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-7-7 cc bracing.
WEBS
1 Row at midpt 10-11, 6-14. 10-12
REACTIONS. (size) 11=0-5-8, 2=0-7-10, 16=0-7-10
Max Horz 2=548(LC 12)
Max Uplift 11=-664(LC 9), 2=-822(LC 12), 16=-1063(LC 12)
Max Grav 11=1141(LC 18), 2=873(LC 1). 16=1049(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-980/776, 4-5=-742/270, 5-6=-906/521, 6-7=-1135/810, 7-9=-1135/810,
9-10=-935/662, 10-11=-1008/837
BOT CHORD 2-18=-1081/786, 16-18=-1081/786, 15-16=-378/629, 14-15=-373/631, 12-14=-662/935
WEBS 4-18=428/213, 4-16=-324/906, 6-14=-587/728, 7-14=-50559, 9-14=-205/278,
9-12=-663/656, 10-12=-890/1251, 5-16=-718/602
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-11-6, Interior(1) 0-11-6 to 13-0-0, Exterior(2) 13-0-0
to 18-0-4, Interior(1) 18-0-4 to 35-4-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
electronically signed and
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 664 lb uplift at joint 11, 822 lb uplift at
sealed by Magid, Michael, PE
joint 2 and 1063 lb uplift at joint 16.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall A�
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI! quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
ERIK MELVILLE
T21280402
76952
D4
HALF HIP
]Ply
1
1
Job Reference (optional)
3
oars I russ, Inc., t-ort Pierce, FL 8.330 s Jul 22 2020. MiTek Industries, Inc. Fri Sep 11 14:19:13 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-7b2tGyXno3kgscaJpBd387Wrb4cKVSvoybOBkmyegpC
-2-6-0 6-1-6 7-7-10 11-7-13 15-0-0 21-10-9 28-7-7 35-6-0
2-6-0 6-1-6 1-0 4 4-0-3 3-4-3 6-10-9 6-8-13 6-10-9
Scale: 3/16"=l'
6x8 = 4x4 = 4x8 = 4x4 = 5x6 =
6.00 12 523 24 25 6 726 8 27
_ 45 =
3x4 II 3x6 =6x8 = 3x8 = 3x4 = 3x4 = 3x6 II
11-7-13
3x6 =
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.43
BC 0.25
WB 0.89
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefl L/d
-0.05 12-14 >999 360
-0.11 12-14 >999 240
-0.02 10 n/a n/a
0.06 17-20 >999 240
PLATES GRIP
MT20 244/190
Weight: 267 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pur ins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 9-10, 6-14, 9-11
REACTIONS. (size) 10=0-5-8, 2=0-7-10, 15=0-7-10
Max Horz 2=612(LC 12)
Max Uplift 10=-573(LC 9), 2=-577(LC 12), 15=-1409(LC 12)
Max Grav 10=1008(LC 17), 2=527(LC 1), 15=1564(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-342/295, 34=478/278, 4-5=-376/144, 5-6=-305/188, 6-8=739/503, 8-9=-645/447,
9-10=-882/727
BOT CHORD 2-17=-736/343, 15-17=-731/342, 12-14=-503/739, 11-12=-447/645
WEBS 3-17=448/241,4-15=-129011144,4-14=-695/862, 5-14=-1 52/285, 6-14=-679/536,
8-11=-527/560, 9-11=-677/972, 3-15=4931994
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-11-6, Interior(1) 0-11-6 to 15-0-0, Exterior(2) 15-0-0
to 20-0-4, Interior(1) 20-0-4 to 35-4-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
Will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
electronically Signed and
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 573 lb uplift at joint 10, 577 lb uplift at
b Magid,
joint 2 and 1409 lb uplift at joint 15.
sealed Y 9 Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.63681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
M Design valid for use only with Tek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 quality Cdferia, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280403
76952
D5
HIP
1
1
Job Reference (optional)
o.d3u s Jui Zz Zuzu mi i eK nausmes, Inc. t-n Sep 11 14:1`J:1d Zulu rage 1
I D: mis7TW UG3iZ7eEyY9QLybykl5J-MYsmJfbwd bNyyNTHckD ErBEhL5FBAiwX6t5yPyeg p7
2-6-0 511-9 8-7-10 11-7-13 17-0-0 25-10-11 34-9-5 3 3 43-8-0 -10
2-6-0 5-11-9 2-8-1 3-0-3 5-4 8-10-11 8-10-11 0- 5 8 4-12 -2-6
6x8 =
6.00 12
625
Scale=1:81.9
5x6
44 = 4x8 = 44 = 4x8 =
26 27 7 8 9 28 10 11
4x5 =
3x4 II 6x8-= 3x6 =V 3x4 = 3x6 = 3x4 = 3x6 II
3x8 =
11-7-13 17-0-0
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefi Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) -0.19 12-13 >604 360 MT20 244/190
TCDL 10.0 Lumber DOL 1.25 BC 0.46 Vert(CT) -0.35 12-13 >324 240
BCLL 0.0 Rep Stress Incr YES WB 0.90 Horz(CT) -0.02 12 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Wind(LL) 0.06 18-19 >999 240 Weight: 321 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
9-15,11-13: 2x4 SP M 30 WEBS 1 Row at midpt 6-16, 7-16, 7-15, 9-13, 11-12
REACTIONS. All bearings 0-7-10 except Qt=length) 13=0-5-8, 12=0-5-8.
(lb) - Max Horz 2=641(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-586(LC 12), 18=-1455(LC 12), 13=-549(LC 12).
12=-415(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) except 2=556(LC 1), 18=1579(LC 1), 13=1291(LC 17),
12=566(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=407/326, 3-5=-437/216, 5-6=-604/393, 6-7=-503/459, 7-9=780/720,
9-10=-253/404, 10-11=-340/473, 11-12=460/640
BOT CHORD 2-19=-796/392, 16-19=-796/392, 15-16=-668/770, 13-15=-352/253
WEBS 3-19=-431/237, 5-18=-1311/1275, 5-16=-722/831, 6-16=-174/316, 7-16=442/416,
7-15=-274/366, 9-15=4601795, 9-13=-1065/1001, 11-13=4581319, 3-18=483/956
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=45ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 1-10-10, Interior(1) 1-10-10 to 17-0-0, Exterior(2)
17-0-0 to 23-4-2, Intedor(1) 23-4-2 to 43-8-0, Exterior(2) 43-8-0 to 44-8-10 zone; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
electronically Signed and
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Magid, Michael, PE
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
using a Digital Signature.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 586 lb uplift at joint 2, 1455 lb uplift at
Printed copies of this
joint 18, 549 lb uplift at joint 13 and 415 lb uplift at joint 12.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�®
Val-
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
bullding design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
i�iTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280404
76952
D6
HIP
1
1
Job Reference (optional)
a.ncnwais r r uss, uic., runt rrerce, rL 0.3JU S Jul Z2 2UZU MI I eK Inaustnes, Inc. Fn Sep i l 14:19:ZU ZUZU Page 1
I D:m Is?T W U G 3iZ?e EyY9QLybykl5J-IxzW kLdA8D dg Cg cfk9FiwcJw5vwleczgZBa2Tsyegp5
2-60 , 511-9 9-7-10 i1-7-13 19-0-0 26-7-4 34-0-12 41.8-0 44-7-10 47-2-'14
2 6-03-8-1 2-0-3 7�-3 7-7 4 7-5 8 7-7 4 2-11-10 2-7-0
6.00 12 6x8 = 4x4 = 4x6 = 3x4 II
6 28 729 8 9 30 31
6x8 =
10 32
Scale = 1:85.3
cc a, is to 10 I. 14 IS
4x6 — 3x4 II 6x8 = 3x6 = 4x5 = 3x5 = 3x6 = 3x8 = 3x4 II 10x10 =
4x6 11
5-11-9
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.92
BC 0.54
WB 0.93
Matrix -MS
DEFL. in (loc) Ildefl L/d
Vert(LL) -0.28 15-16 >999 360
Vert(CT) -0.52 15-16 >762 240
Horz(CT) -0.01 14 n/a n/a
Wind(LL) 0.30 15-16 >999 240
PLATES GRIP
MT20 244/190
Weight: 373 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEDGE WEBS 1 Row at midpt 5-21, 5-19, 6-19, 6-18, 7-18, 9-16, 10-16,
Left: 2x4 SP No.3 10-15, 11-14, 12-13, 12-14
REACTIONS. All bearings 0-7-10 except Qt=length) 14=0-5-8, 13=0-5-8.
(lb) - Max Horz 2=564(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-410(LC 12), 21=-1942(LC 12), 14=-1036(LC 17),
13=-1084(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 2 except 21=2722(LC 17), 14=444(LC 9), 13=2304(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=243/849, 3-5=-889/1128, 5-6=-738/535, 6-7=-119811041, 7-9=-1321/1134,
9-1 0=-1 321/1134, 10-11 =-1 182/916, 11-12=-754/510, 12-13=-2430/1568
BOT CHORD 2-22=-786/0, 21-22=-786/0, 19-21 =-870/654, 18-19=-367/640,16-18=-793/1244,
15-16=-511/839, 14-15=-514/838
WEBS 3-22=-451/227, 5-21=-2436/1930, 5-19=-1240/1873, 6-19=-908/847, 6-18=-741/1057,
7-18=-627/631, 9-16=-547/620, 10-16=611/821, 11-14=1087/876, 12-14=-1564/2550,
3-21=-502/947
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-1-7, Interior(1) 2-1-7 to 19-0-0, Exterior(2) 19-0-0 to
This item has been
25-8-3, Interior(1) 25-8-3 to 41-8-0, Exterior(2) 41-8-0 to 47-1-2 zone; porch left exposed;C-C for members and forces & MWFRS for
electronically signed and
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
sealed Magid, Michael, PE
y g
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies of this
will fit between the bottom chord and any other members, with BCDL = 10.Opsf. ,
document are not Considered
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 410 lb uplift at joint 2, 1942 lb uplift at
signed and sealed and the
joint 21, 1036 lb uplift at joint 14 and 1084 lb uplift at joint 13.
7) This truss has large uplift reaction(s) from gravity load case(s) at Joint 14. Proper connection is required to secure truss
signature must be verified
against upward movement at the bearings. Building designer must provide for uplift reactions indicated.
On any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL $3610
Date:
September 11,2020
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall /�
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iVliT®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSHTP11 quality Criteria, OSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
a
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280405
76952
D7
PIGGYBACK BASE
1
1
Job Reference o tlonal
• �•• •_, O.000 s Jul zz LULU wtl t ex inuustnes, Inc. rn cap i 174:1e24 zuzu rage l
ID:mis7TWUG3iZ1eEyY9QLybykl5J-AiD1 ajghCR76glwRz7Ke4SUisW KuaWwQUoYGceyegpl
-2-" , 5 11-9 9-7-10 11-7-13 19.0.0 26.7-4 34-0-12 41-8-0 47-2-14
2-6-0 5 11-9 3 8-1 2-0-3 7-4-3 7-7-4 7-5 8 7-7 4 5-6-14
TOP CHORD UNDER PIGGYBACKS TO BE LATERALLY Scale=1:84.9
BRACED BY PURLINS AT 2-M O.C. MAXIMUM.
TYPICAL FOR ALL APPLICABLE TRUSS DESIGNS
IN THIS JOB.
4x4 = 4x6 = 3x4 II 6x8 =
6x8 = 6 26 727 8 9 28 29 10 30
5x6
4x6 �4x5 - 11
6.00 12
5 25
4
0
4x4 i N
d
3 rn
�24
1 2. , \
20 19 31 18 17 32 16 15 14 33 13 34
12
4x5 — 3x4 II 6x8 = 3x6 = 3x5 = 3x5 = 3x6 = 3x8 = 3x5 = 3x6 II
&11-9
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL_ 10.0
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
SPACING-
2-0-0
CSI.
DEFL.
in (loc) Vdefl Ud
PLATES GRIP
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
-0.10 14-16 >999 360
MT20 244/190
Lumber DOL
1.25
BC 0.37
Vert(CT)
-0.18 14-16 >999 240
Rep Stress Incr
YES
WB 0.48
Horz(CT)
0.03 12 n/a n/a
Code FBC20171TP12014
Matrix -MS
Wind(LL)
0.09 14-16 >999 240
Weight: 362 lb FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc purlins,
except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-19, 5-17, 6-17, 6-16, 7-16, 7-14, 9-14.
10-14,
10-13, 11-12, 11-13
REACTIONS. (size) 2=0-7-10, 19=0-7-10, 12=0-5-8
Max Horz 2=564(LC 12)
Max Uplift 2=-597(LC 12), 19=-1672(LC 12), 12=-855(LC 12)
Max Grav 2=534(LC 21), 19=2124(LC 17), 12=1587(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=354/338, 3-5=-373/298, 5-6=-10741770, 6-7=-135211174, 7-9=-1317/1169,
9-10=-1317/1169, 10-11=-908/735, 11-12=-1497/1196
BOT CHORD 2-20=-678/315, 19-20=-678/315, 16-17=-580/947, 14-16=-926/1395, 13-14=-521/739
WEBS 3-20=-441/217, 5-19=-1865/1592, 5-17=-926/1300, 6-17=-601/652, 6-16=-628/826,
7-16=-458/535, 9-14=-479/556, 10-14=-652/949, 10-13=-712/710, 11-13=-848/1196,
3-19=-448/907
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-1-7, Interior(1) 2-1-7 to 19-0-0, Exterior(2)19-0-0 to
25-8-3, Interior(1) 25-8-3 to 41-8-0, Exterior(2) 41-8-0 to 47-1-2 zone; porch left exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 597 lb uplift at joint 2, 1672 lb uplift at
joint 19 and 855 lb uplift at joint 12.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify, the applicability of design parameters and property Incorporate this design Into the overall r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlf Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
MELVILLET21280406
76952
D8
PIGGYBACK BASE
1
JERIK
Reference o tional
...... d.aau s uul zz zuzu mi i ex industries, Inc. rn bep i i 14:1`J:zb zuzU rage 1
I D: mis?T W UG3iZ?eE_rYg QLybyklSJ-75Ln?Ohxk3Ngwb4p4QM6AfZ2YKOR2QMjx62Nh W yegp?
-2-0 0 5-11-9 9-7-10 11-7-13 19-0-0 26-7-4 34 0-12 41-8-0 47-0-14
2 6-0 5 11-9 3 8-1 7�-3 7-7-0 7-5 8. 7-7 4 5 4-14
�i
6x8 =
4x4 = 4x6 = 3x4 II
6 26 7 27 8 9 28 29
6x8 =
10 30
Scale=1:84.6
4x5 — 3x4 II 6x8 = 3x6 = 3x5 = 3x5 = 3x6 = 3x8 = 3x5 = 3x6 II
41-8-0
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Cade FBC2017ITP12014
CSI.
TC 0.48
BC 0.37
WB 0.49
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefl L/d
-0.09 14-16 >999 360
-0.18 14-16 >999 240
0.03 12 n/a n/a
0.09 14-16 >999 240
PLATES GRIP
MT20 244/190
Weight: 362 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-19, 5-17, 6-17, 6-16, 7-16, 7-14, 9-14,
10-14,
10-13, 11-12, 11-13
REACTIONS. (size) 2=0-7-10, 19=0-7-10, 12=0-3-8
Max Horz 2=570(LC 12)
Max Uplift 2=-596(LC 12), 19=-1669(LC 12), 12=-851(LC 12)
Max Grav 2=534(LC 21), 19=2114(LC 17), 12=1575(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-354/335, 3-5=-377/297, 5-6=-1066/763, 6-7=-1337/1163, 7-9=-1296/1154,
9-10=-1296/1154,10-11=-880/715,11-12=-1490/1192
BOT CHORD 2-20=-681/316, 19-20=-681/316, 16-17=-579/940, 14-16=-921/1381, 13-14=-508/716
WEBS 3-20=-441/217, 5-19=-1855/1587, 5-17=-921/1292, 6-17=-597/649, 6-16=-620/813,
7-16=-452/528, 9-14=-479/557, 10-14=-659/954, 10-13=-725/720, 11-13=-849/1191,
3-19=448/907
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=47ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -2-7-4 to 2-14, Interior(1) 2-1-4 to 19-0-0, Exterior(2)19-0-0 to
25-7-14, Interior(1) 25-7-14 to 41-8-0, Exterior(2) 41-8-0 to 46-11-2 zone; porch left exposed;C-C for members and forces 8 MWFRS
for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically Signed and
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
fit between
sealed b Magid, Michael, PE
Y 9
will the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 596 lb uplift at joint 2, 1669 lb uplift at
using a Digital Signature.
joint 19 and 851 lb uplift at joint 12.
Printed Copies Of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web andlor chord members only. Additional temporary and permanent bracing
MOW
I Vi�
lek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
MELVILLE
T21280407
76952
D9
PIGGYBACK BASE
1
1
IERIK
Job Reference o tlonal
� ��• �•��� o.J3U a Jul zz zuzu mi I eK 1naus[nes, Inc. t-n sep 11 14:19:27 ZUZU Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-bHv9CkiZVMVhYJfOe7tLi46E3jM3nsl sAmnwDzyegp_
2-6-0 6-4-14 9-7-10 12 6 6 19-0-0 26-7-4 34-0-12 41-8-0 45-2 4
2-6-0 66 .14 3-2-13 2-10-12 6-5-10 7-7-4 7-5-8 7-7r1 3-6 4
6x8 =
6.00 12
6
4x4 = 4x6 = 3x4 II 6x8 =
25 7 26 8 9 27 28 10
Scale = 1:81.4
I ,v ,v w 11
4x5 — 3x4 II 6x8 = 3x6 = 3x5 = 3x5 = 3x6 = 3x8 = 3x5 = 3x6 II
6-4-14
34-0-12
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Cade FBC2017/TPI2014
CSI.
TC 0.43
BC 0.34
WB 0.52
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Vdefl Ud
-0.09 13-14 >999 360
-0.17 13-14 >999 240
-0.02 12 nla file
0.08 14-16 >999 240
PLATES GRIP
MT20 244/190
Weight: 356 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-19, 5-17, 6-17, 6-16, 7-16, 7-14, 9-14.
10-14,
10-13, 11-12, 11-13
REACTIONS. (size) 2=0-7-10, 19=0-10-13, 12=0-5-8
Max Horz 2=630(LC 12)
Max Uplift 2=-621(LC 12), 19=-1660(LC 12), 12=-782(LC 12)
Max Grav 2=567(LC 21), 19=2015(LC 17), 12=1383(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-411/377, 3-5=-422/294, 5-6=-871/577, 6-7=-1146/957, 7-9=-1057/921,
9-10=-1057/921,10-11=-554/455,11-12=-1386/1079
BOT CHORD 2-20=-793/371, 19-20=-793/371, 16-17=-476/755, 14-16=-796/1175, 13-14=-325/449
WEBS 3-20=-471/248, 5-19=-1753/1498, 5-17=-851/1182, 6-17=-621/670, 6-16=-579/752,
7-16=4121495, 9-14=-478/561, 10-14=-709/1001, 10-13=-833/809, 11-13=838/1150,
3-19=-519/1021
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf, BCDL=3.Opsf; h=20ft; 8=45ft; L=45ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 1-11-0, Interior(1)1-11-0 to 19-0-0, Exterior(2) 19-0-0
to 25-4-11, Interior(1) 25-4-11 to 41-8-0, Exterior(2) 41-8-0 to 45-0-8 zone; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads,
'
electronically Signed and
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
sealed b Magid, Michael, PE
Y 9
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 621 lb uplift at joint 2, 1660 lb uplift at
using a Digital Signature.
joint 19 and 782 lb uplift at joint 12.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall p /�•
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VI�Te k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TP/1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, M6904 Parke East Blvd.
D 20601 Tempe, Parke
36610
East
Job
Truss
Truss Type
Qty
Ply
T21280408
76952
D9A
PIGGYBACK BASE
1
1
�ERIKMELVILLE
Job Reference (optional)
•- • •- o.oJu s oui cc cucu Iwl i eK rrausines, Inc. rn oep 11 i4:1a:su zuzu vage 1
ID: mis?T W UG3iZ?eEyY9QLybykl5J-?sa IgmkSoHtFP D N aJF R2Kj ld ]xNz_9KIsk0apHyegox
2-6-0 7144
4-14 9-7-10 14-6-6 19-0-0 26-7-4 34-0-12 41-8-0 45-2-4
2-6-0 7-4-14 2-2-13 4-10-12 4-5-16 7-7-4 7-5-8 7-7-4 3-6-4
6x8 =
6.00 12
6
4x4 = 4x6 = 3x4 II 6x8 =
26 7 27 8 9 28 29 10
Scale=1:81.4
4x5 —_ 3x4 II 3x6 = 3x5 = 3x5 = 3x6 = 3x8 = 3x5 = 3x6 II
6x8 =
26-7-4
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017fTP12014
CSI.
TC 0.43
BC 0.33
WB 0.81
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft Ud
-0.09 13-14 >999 360
-0.16 13-14 >999 240
-0.03 12 n/a n/a
0.12 20-23 >999 240
PLATES GRIP
MT20 244/190
Weight: 359 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-19, 5-17, 6-17, 6-16, 7-16, 7-14, 9-14,
10-14, 10-13, 11-12, 11-13
REACTIONS. (size) 2=0-7-10, 19=0-10-13, 12=0-5-8
Max Horz 2=630(LC 12)
Max Uplift 2=-733(LC 12), 19=-1699(LC 12), 12=-723(LC 12)
Max Grav 2=672(LC 21), 19=1944(LC 2), 12=1317(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-592/607, 3-5=-351/232, 5-6=-639/395, 6-7=-1011/814, 7-9=-983/834,
9-10=-983/834,10-11=-527/424,11-12=-1320/1003
BOT CHORD 2-20=-988/492, 19-20=-988/492, 16-17=-264/527, 14-16=-653/1019, 13-14=-299/426
WEBS 3-20=-537/303, 5-19=-1679/1396, 5-17=-775/1096, 6-17=-738/758, 6-16=-680/842,
7-16=-475/574, 9-14=-476/558, 10-14=-610/894, 10-13=-773/746, 11-13=-770/1091,
3-19=-647/1246
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf, BCDL=3.Opsf; h=20ft; B=45ft; L=45ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 1-11-0, Interior(1) 1-11-0 to 19-0-0, Exterior(2)19-0-0
to 25-4-11, Interior(1) 25-4-11 to 41-8-0, Exterior(2) 41-8-0 to 45-0-8 zone; porch left exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water por ding.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically signed and
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = I O.Opsf.
sealed b Magid, Michael, PE
y g
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 733 lb uplift at joint 2, 1699 lb uplift at
using a Digital Signature.
joint 19 and 723 lb uplift at joint 12.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall p quo
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iVliTe k•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/i Quality Criteria, DSB-89 and Bost Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
ERIK MELVILLE
T21280409
76952
F
Common
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
5-7-10
7-5-2
5x6 =
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:33 2020 Page 1
5-4-6
22-0-0
Scale = 1:43.9
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL)
-0.09
8-10
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.30
Vert(CT)
-0.15
8-10
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.26
Horz(CT)
0.03
6
n/a
n1a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.08
8-10
>999
240
Weight: 133 lb FT = 20%
LUMBER -
TOP CHORD
2x6 SP No.2
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
REACTIONS.
(size) 2=0-7-10, 6=0-7-10
Max Horz 2=279(LC 11)
Max Uplift 2=-783(LC 12), 6=-783(LC 12)
Max Grav 2=1036(LC 1), 6=1036(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-1378/949, 3-4=-1213/933, 4-5=-1213/933, 5-6=-1378/948
BOT CHORD 2-10=-574/1288, 8-10=-309/871, 6-8=-660/1151
WEBS 4-8=-302/495, 5-8=-295/358, 4-10=-302/493, 3-10=-295/359
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-11-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-0-4 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 11-0-0, Extedor(2) 11-0-0 to
14-0-0, Interior(1) 14-0-0 to 24-7-4 zone;C-C for members and forces 6 MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads.
4) • This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 783 lb uplift at joint 2 and 783 lb uplift at
joint 6.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc, FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall HT 11-
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUIPN Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280410
76952
F1
Common
3
1
Job Reference (optional)
I
s i rubs, inc., Puri Pierce, Pt_ 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:35 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-MpNBuTobcpWYV_GY6pOD1 mRbEy6gfYW 10OjLUVyegos
-2-6-0 5-7-10 11-0-0 16-4-6 22-0-0
2-6-0 5-7-10 5-4-6 5.4-6 5-7-10
Scale=1:41.1
5X6 =
...... — DXb =
6
I9
d
7-5-2
14-6-14
22-0-0
7-5-2
7-1-13
7-5-2
Plate Offsets (X,Y)—
[2:Edge,0-0-71, [6:0-0-0,0-0-71
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL) -0.08
7-9 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.30
Vert(CT) -0.15
7-9 >999 240
BCLL 0.0
Rep Stress Incr YES
WS 0.30
Horz(CT) 0.03
6 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.08
7-9 >999 240
Weight: 128 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-11-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 8-1-1 oc bracing.
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (size) 6=Mechanical, 2=0-7-10
Max Horz 2=271(LC 11)
Max Uplift 6=-533(LC 12), 2=-799(LC 12)
Max Grav 6=871(LC 1), 2=1045(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-1396/1013,3-4=-1232/997,4-5=-1265/1062, 5-6=-1433/1081
BOT CHORD 2-9=789/1259, 7-9=-441/843, 6-7=-830/1215
WEBS 4-7=-345/540, 5-7=-328/393, 4-9=-293/493, 3-9=-295/360
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 11-0-0, Exterior(2) 11-0-0 to
14-0-0, Interior(1) 14-0-0 to 22-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
This item has been
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 533 lb uplift at joint 6 and 799 lb uplift at
electronically Signed and
joint 2.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and pennanant bracing MiTek*
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria, DS&89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Type city Ply ERIK MELVILLE
SPECIAL 1 T21280411
Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:37 2020 Page 1
I D: mis?T W UG3iZ?eEyY9QLybykl5J-ICVxJ 9q r8 RmG kl PxDE3h6 B W uH IjO7 KRKTKCSZNyegoq
2-6-0 5-9-10 11-0-0 3-0-0 21-4-1 29-8-3 36-7-10 44-0-0 44- 13 51-4-6 51 -0 60-8-0 3-2-0
2-6-0 5-9-10 5-2-6 -0-0 8-4-2 8-4.2 6-11-7 7-4-6 0-1-13 7-2-9 0-3- 0 9-0-0 256-0
6.00 12
3.4 \\
332
31
01
24
45 = 4x4 =
6x8 =
4 6x8 = 3x4 II
5 33 6 34
4x6 = 4x4 =
23 22 21 20
4x10 = 4x6
4x10 =
4x6 = 4x4 = 4x6 = 3x4 II
9 35 10 11 3637
17
7x8 =
19 18
3x8 II 6x8 = 4.00 12
WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraintbracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
Scale = 1:113.1
6x8 =
12 13
38
39 N
n N
14 jo
N
16 40
7x8 =
4x5 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL) 0.24 16-30 >459 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.16 21-22 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.79
Horz(CT) 0.03 16 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 424 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 5-5-15 oc purlins.
BOT CHORD 2x6 SP No.2
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
WEBS 1 Row at midpt 5-21, 8-21
REACTIONS. All bearings 0-7-10.
(lb) - Max Horz 2=342(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-914(LC 12), 18=-698(LC 12), 16=-558(LC 12), 14=-768(LC
12), 19=-989(LC 12)
Max Grav All reactions 250 lb or less at joints) except 2=1220(LC 17), 18=1049(LC 22), 16=866(LC 22),
14=441(LC 1), 19=1643(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1748/1457, 3-4=-1642/1531, 4-5=-1678/1624, 5-6=-945/1012, 6-8=-945/1012,
8-9=-327/776, 9-11=-57/308, 11-12=-57/308, 12-13=-56/571, 13-14=-16/414
BOT CHORD 2-24=-1026/1678, 22-24=-609/1247, 21-22=-863/1505, 19-21=-804/851, 18-19=-804/851,
17-18=-864/909,16-17=-258/149
WEBS 3-24=-347/452, 4-24=-446/530, 4-22=-807/926, 5-22=-710/779, 5-21=-643/454,
6-21=-542/591, 8-21=-1515/2009, 8-19=-1462/1250, 9-18=-653/661,9-17=-683/815,
11-17=-444/515, 12-17=-61/261, 12-16=-617/429
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=61ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 3-5-9, Interior(1) 3-5-9 to 11-0-0, Exterior(2) 11-0-0 to
13-0-0, Interior(1) 13-0-0 to 51-8-0, Exterior(2) 51-8-0 to 57-8-13, Interior(1) 57-8-13 to 63-34 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI'), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restrainUbracing and the
permanent individual truss member restraintbracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 914 lb uplift at joint 2, 698 lb uplift at
joint 18, 558 lb uplift at joint 16, 768lb uplift at joint 14 and 989lb uplift at joint 19.
® WARNING - Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/f quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty ----
Ply
ERIK MELVILLE
T21280412
76952
G1
HIP
1
1
Job Reference o ticnal
�,ncurucrs r ross, mc., ruri rierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:40 2020 Page 1
ID:m Is?T W UG3iZ?eEyY9QLybykl5J4n B4xBsj RM8rbl8VvMcOkg8 PxzmfKhFn91 R6Aiyegon
-2-6-1 5-7-10 11-0-0. 19-0.9 28-1-1 36-7-10 43-1-13 4 49.8-0 1-4-6 60-8-0 63-2.0
2-6-0 5.7-10 5.4-6 8-0-9 8-6-9 6-6-3 0- 0 5-8-0 -8-6 9-3-10 2-6-0
6xB =
4x4 = 4x6 = 4x4 =
6.00 12 4 34 5 35 6 7
0
46 =
44 = 30 II
8 9 36 10 37
6x8 =6x8
11 12
4x5 = — —23 40 dva = 41 21 `V 1942 18 .- 10
'AX4 11 7x8 =
4.00 112 x°
WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraintibracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
51-8.3
5-7-10 11-0-0 19-6-9 28-1-1 2 4 33-0-0 36-7-10 44.0-0 49-8-0 1-" 60-8-0
5.7.10 Sd-6 8-6-9 8-6.9 -3-5 3.7-10 3-7-10 5-8-0 -8-6 8.11.13
7x8 =
Scale = 1:109.4
4x5 =
Plate Offsets (X,Y)—
[4:0-5-4,0-3-01, [11:0-5-4,0-3-01, [12:04-0,0-4-4], [13:Edoe 0-2-0] rl8.0-5-4 04-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(LL) 0.21 15-31 >537 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.50
Vert(CT) -0.21 20-22 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.78
Horz(CT) 0.05 15 file n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 437 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins.
BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 4-22, 5-20, 7-18
REACTIONS. All bearings 0-7-10 except Qt=length) 18=7-3-4, 18=7-3-4, 19=0-3-8.
(lb) - Max Horz 2=-343(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-1013(LC 12), 18=-1294(LC 12), 15=-545(LC 12),
13=-740(LC 12), 19=-335(LC 12)
Max Grav All reactions 250 lb or less at joint(s) except 2=1448(LC 17), 18=2015(LC 1), 18=2015(LC 1), 15=726(LC
22), 13=469(LC 1), 19=702(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2172/1791, 3-4=-1792/1541, 4-5=-1518/1490, 5-7=-420/619, 7-8=-375/977,
8-10=0/349, 10-11=0/349, 11-12=-1501508, 12-13=-61/370
BOT CHORD 2-25=-1349/2093, 24-25=-1349/2093, 22-24=-888/1715, 20-22=-923/1645, 19-20=-61/411,
18-19=-61/411, 17-18=-983/1063, 16-17=-176/358
WEBS 3-24=-443/530, 4-24=-217/431, 5-22=0/400, 5-20=-1484/1047, 7-20=-119/414,
7-18=-1517/1195, 8-18=-802/731, 8-17=-485/766,10-17=-411/530,11-17=-204/301,
11-16=-504/188,12-16=-165/735,12-15=-561/274
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=61ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 3-5-9, Interior(1) 3-5-9 to 11-0-0, Exterior(2) 11-0-0 to
19-6-9, Interior(1) 19-6-9 to 49-8-0, Exterior(2) 49-8-0 to 58-2-15, Interior(1) 58-2-15 to 63-3-4 zone; porch right exposed;C-C for
This item has been
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
electronically signed and
3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
sealed by Magid, Michael, PE
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owners authorized agent shall contract with a
using a Digital Signature.
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
Printed copies of this
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
document are not considered
bracing.
4) Provide adequate drainage to prevent water ponding.
signed and Sealed and the
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signature must be Verified
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
on any electronic copies.
will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
Michael S. Magid PE No.53681
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1013 lb uplift at joint 2, 1294 lb uplift at
MiTek USA, Inc. FL Cart 6634
joint 18, 545 lb uplift at joint 15, 740 lb uplift at joint 13 and 335 lb uplift at joint 19.
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall rt{{ qA�s
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IVI� 1T�i k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280413
76952
G2
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:44 2020 Page 1
7163-0-0-0 27-10.9 278-1-90--91 ID:mis7TWUG3iZ7eEyY9QLybykl5J-bYQbnYvEVaeG4MSH8ChKugJ2la4iGSvM4vPKJTyegoj
-2-0 7-0-0 0-10-9 -7-10 42
-1-4785-0-6 0-0 362-036
27-10-9 5-63 -A 662
6.00 12 6x8 =
4x5 i
4x6 =
4x4 = 5x6 = 4x4 = 4x4 = 3x4 II 6x8
35 636 37 7 e 9 1038 39 11 40 12
Scale = 1:111.2
46 G 4x6 Q34143334 4142 N4x6r`2 r4x41914 N>V41^3
.7x8 = 1
26 25 24 43 23 22 44 21 45 20 4x6 17
3x4 II 46 = 4x4 = 5x6 = 4x4 = 6x8 = 7x8 = 5x6 =
WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ('SCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
Plate Offsets (X,Y)—
[5:0-5-4,0-3-01, [12:0-5-8,0-3-01, [15:Edge 0-2-81, [17:0-5-12,0-4-121 [20:0-54,0-3-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.78
Vert(LL) -0.21 21-23 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.69
Vert(CT) -0.43 21-23 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.93
Horz(CT)
0.14 17 n/a We
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Wind(LL)
0.33 21-23 >999 240
Weight: 449 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc puriins.
BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 4-8-4 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 5-23, 6-21, 8-20, 10-19, 12-18, 13-17
REACTIONS. (size) 2=0-7-10, 17=0-7-10, 15=0-7-10
Max Horz 2=-393(LC 10)
Max Uplift 2=-1417(LC 12), 17=-2372(LC 12), 15=-980(LC 17)
Max Grav 2=2156(LC 17), 17=3668(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3614/2823, 4-5=3166/2571, 5-6=3360/2876, 6-8=3121/2752, 8-1 0=-2208/21 10,
10-11=-1090/1126,11-12=-1090/1126,12-13=01580,13-15=-1360/2469
BOT CHORD 2-26=-2252/3397, 24-26=-2252/3397, 23-24=-1752/2953, 21-23=-2199/3504,
20-21=-2075/3264, 19-20=-1528/2399, 18-19=-523/727, 17-18=-2247/1761,
15-17=-2035/1572
WEBS 4-24=-531/591, 5-24=-289/527, 5-23=-712/932, 6-23=-454/517, 6-21=-314/163,
8-21=-54/470, 8-20=-1328/843, 10-20=-26/307, 10-19=-1393/1147, 11-19=385/510,
12-19=-1722/2293,12-18=-2000/1308,13-18=-1296/2292,13-17=-2768/2170
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=61ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 3-5-9, Interior(1) 3-5-9 to 13-0-0, Exterior(2) 13-0-0 to
21-6-15, Interior(1) 21-6-15 to 47-8-0, Exterior(2) 47-8-0 to 56-2-15, Interior(1) 56-2-15 to 63-3-4 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
electronically signed and
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses
led b Magid, Michael, PE
seaY 9
("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
using a Digital Signature.
permanent individual truss member restrainUbracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
Printed copies of this
bracing.
4) Provide adequate drainage to prevent water ponding.
document are not considered
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signed and Sealed and the
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signature must be verified
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
On any electronic Copies.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1417 lb uplift at joint 2, 2372 lb uplift at
Michael S. Magid PE No.53681
joint 17 and 980 lb uplift at joint 15.
MiTek USA, Inc. FL Cert 6634
0904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall"
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPN Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
MELVILLET21280414
76952
G3
HIP
1
[Iy7TER11K
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:19:45 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-31_z uwsGum7iWlThvCaRtrFj_Rj?vOWJZ8trwyegoi
r-2-600 , 7-8-13 15-0-0 22-2-9 29-5-1 36-7-10 45-8-0 51-4-6 60-8-0 63-2-0
2 6-0 7,
7-3 3 7-2-9 7-2-9 7-2-9 9-0.6 5 8 6 9.3% 2 6-0
4x4 =
6x8 =
6.00 12 4x4 = 4x6 =
5 32 6 33 34 7 8
4x5
4x6 i
4
3
4x6 = 31
2 4x4 =
;1 5x6 =
3x4 11 23 39
21 2040 19 41
24 5x6 = 22 4x4 = 4x4 =
4x4 = 6x8 =
935 36 37 10
6x8 1
11 46
12
38
1716
18 4.00 12 6x8 I
6x8 = 4x6 -- 15
7x8 =
WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Udell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.67
Vert(LL)
-0.19 19-21
>999
360
TCDL
10.0
Lumber DOL
1.25
BC 0.64
Vert(CT)
-0.38 19-21
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.94
Horz(CT)
0.14 15
n/a
n/a
BCDL
10.0
Code FBC2017/rP12014
Matrix -MS
Wind(LL)
0.29 19-21
>999
240
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-7-10, 15=0-7-10, 13=0-7-10
Max Horz 2=-443(LC 10)
Max Uplift 2=-1445(LC 12), 15=-2191(LC 12), 13=-764(LC 17)
Max Grav 2=2219(LC 17), 15=3388(LC 1)
Scale = 1:111.2
46 =
PLATES GRIP
MT20 244/190
Weight: 457 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-9-8 oc bracing.
WEBS 1 Row at midpt 4-22, 5-21, 6-19, 7-18, 9-17, 10-16, 11-16,
11-15
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3744/2894, 4-5=-3143/2556, 5-6=-3117/2721, 6-7=2868/2588, 7-9=-2141/2125,
9-10=-1158/1211, 10-11=-884/900, 11-13=-960/2017
BOT CHORD 2-24=-2318/3547, 22-24=-2318/3547, 21-22=-1694/2938, 19-21 =-1 977/3277,
18-19=-1844/3029, 17-18=-1462/2373, 16-17=-186/677, 15-16=-1820/1372,
13-15=-1635/1217
WEBS 4-24=0/264, 4-22=-706f717, 5-22=-324/590, 5-21=-548/730, 6-21=-399/450,
6-19=-363/194, 7-19=94/525, 7-18=-1168/678, 9-18=-10/296, 9-17=-1318/1169,
10-1 7=-1 18411766, 10-16=-1701/1178, 11-16=-1514/2622, 11-15=-2665/2152
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=61ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 3-5-9, Interior(1) 3-5-9 to 15-0-0, Exterior(2) 15-0-0 to
23-6-15, Interior(1) 23-6-15 to 45-8-0, Exterior(2) 45-8-0 to 54-2-15, Interior(1) 54-2-15 to 63-3-4 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI'), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1445 lb uplift at joint 2, 2191 lb uplift at
joint 15 and 764 lb uplift at joint 13.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
--
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
SafetyInformation available from Tress Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
]Truss
T21280415
76952
G4
Hip
1
1
Job Reference (optional)
- - ••--•- • •---� •• •-•• • -• • • •-• w� o.JJu s dui cc tutu ml ten Inuusmes, Inc. rS n ep it 14:1e:4b ZUZU rage 1
ID:mis7TWUG3iZ7eE-yY9QLybyklSJ-XxYLBExU1 Cu_JgcfFdjpz500nOkTkOSfYDuQNMyegoh
-2-6-0 8-7-10 17-0-0 26-9-13 36-7-10 43-8-0 51-0-6 53-8-8
2 6-0 8-7-10 8 4-0 9-9-13 9-9-13 7-0.6 7 1, 2 4-2
4x4 =
6x8 =
6.00 12 46 =
526 27 6 7
4x4 =
28 8 29 30
7x8 =
9
Scale = 1:98.9
N_
N
zu -- 18 -- 16 '- 15 13 12
Sx6 =
3x4 II 5x6 = 40 = 4x4 = 6x8 = 4.00 12 6x8 = 4x10 II
4x6 =
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017rrP12014
CSL
TC 0.78
BC 0.79
WB 0.80
Matrix -MS
DEFL. in (loc) Udefl Ud
Vert(LL) -0.24 15-16 >999 360
Vert(CT) -0.49 15-16 >999 240
Horz(CT) 0.20 12 n/a n/a
Wind(LL) 0.34 16 >999 240
PLATES GRIP
MT20 244/190
Weight: 413lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-4-5 oc pudins,
BOT CHORD 2x6 SP No.2
except end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 4-3-1 oc bracing.
5-16,6-15: 2x4 SP M 30
WEBS
1 Row at midpt 4-18, 5-16. 6-16, 6-15. 8-15, 8-14, 10-14
REACTIONS. (size) 2=0-7-10, 12=0-5-8
Max Harz 2=370(LC 11)
Mai Uplift 2=-1569(LC 12), 12=-1338(LC 12)
Max Grav 2=2473(LC 17), 12=2153(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-4266/3147, 4-5=-3562/2782, 5-6=-3535/2989, 6-8=-2896/2638, 8-9=-2738/2456,
9-10=-3227/2661, 10-11=-1097/920, 11-12=-2134/1765
BOT CHORD 2-20=-2922/3943, 18-20=-2922/3943, 16-18=-2258/3229, 15-16=-2583/3619,
14-15=-2352/3150, 13-14=-857/1033
WEBS 4-20=0/304,4-18=-821r757,5-18=-320/701,5-16=-550/808, 6-16=-333/437,
6-15=-866/469,8-15=-419/476,8-14=383/226,9-14=-714/1074,10-14=-1350/1978,
10-13=-1924/1767,11-13=-167911976
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10: Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf, h=20ft; B=45ft; L=54ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-9-4, Interior(1) 2-9-4 to 17-0-0, Exterior(2) 17-0-0 to
24-7-2, Interior(1) 24-7-2 to 43-8-0, Extefior(2) 43-8-0 to 51-6-2, Interior(1) 51-6-2 to 53-6-12 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1569 lb uplift at joint 2 and 1338 lb uplift
at joint 12.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall f��-
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VIiT®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
s
Truss Type
city]Ply
ERIK MELVILLE
FG6
T21280416
76952
Hip
1
1
Job Reference o tional
<a 1- Ivu I eK 11l
uusme5, inc. rn aep -i -i-14:1e:04 ZUZU rage 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-IT1 Ntzl V8fvsHvDCjlshlnjjVcVyb?ggNTgsfuyegoZ
-2-6-0 9-7-10 19-0-0 2__ -13 36-7-10 41-8-0 51-4-6 53-8-8
2 6-0 9-7-10 9-4-6 8-9-13 B-9-13 5-0-6 9.8-6 2 4-2
Scale=1:98.9
6x8 =
6.00 12 4x4 = 4x6 = 4x4 =
5 27 6 7 28 29 6 30
6x8 =
9
21 __ 19 .""" 17 "' 16 4x4 13 12
3x4 II 5x6 = 4x4 = 4x6 = 4x4 = 6x8 =
Sx6 = 4.00 12 6x8 = 410 I
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.92
BC 0.69
WB 0.84
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft Ud
-0.21 16-17 >999 360
-0.42 16-17 >999 240
0.19 12 n/a n/a
0.31 17 >999 240
PLATES GRIP
MT20 244/190
Weight: 434 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins,
BOT CHORD 2x6 SP No.2
except end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 4-3-14 oc bracing.
5-17,6-16: 2x4 SP M 30
WEBS
1 Row at midpt 3-19, 6-17, 6-16, 8-16, 8-15, 10-14
REACTIONS. (size) 2=0-7-10, 12=0-5-8
Max Horz 2=419(LC11)
Max Uplift 2=-1569(LC 12), 12=-1338(LC 12)
Max Grav 2=2471(LC 17), 12=2167(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4234/3099, 3-5=-3385/2669, 5-6=-3153/2746, 6-8=-2589/2424, 8-9=-2530/2325,
9-1 0=-3193/2613, 10-11 =-1 112/922, 11-12=-2151/1756
BOT CHORD 2-21=-2866/3942, 19-21=-2866/3942, 17-19=-2106/3077, 16-17=-2274/3254,
15-16=-2059/2830,14-15=-1936/2631,13-14=-915/1091
WEBS 3-21=0/367, 3-19=-990/865, 5-19=-364/761, 5-17=-380/595, 6-17=-257/345,
6-16=-863/479, 8-16=-324/337, 8-15=-346/195, 9-15=-204/423, 9-14=-527/771,
10-14=-1201/1913,10-13=-2052/1889,11-13=-180212108
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=54ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-9-4, Interior(1) 2-9-4 to 19-0-0, Exterior(2) 19-0-0 to
26-7-2, Interior(1) 26-7-2 to 41-8-0, Exterior(2) 41-8-0 to 49-3-2, Interior(1) 49-3-2 to 53-6-12 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
electronically Signed and
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Magid, Michael, PE
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
using a Digital Signature.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1569 lb uplift at joint 2 and 1338 lb uplift
Printed copies of this
at joint 12.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeIC°
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
city
Ply
ERIK MELVILLE
]Truss
T21280417
76952
G6
Piggyback Base
1
1
Job Reference (optional)
_.._...__._ ......... ....... ...,, . ,,,,,.,,, . O.JJU s VUI G GUGU IVII I arc mausines, inc, rn Jep 11 i4nv:of LULU rage 1
I D:m Is7T W U G3iZ7eEyY9QLybykl SJ-i2j VV73ORaHQBMxnO QQOwPLEIp WfoMZH4R2 W GDyegoW
210 9-7-12 19-0-0 27-9-13 36-7-10 418-0 51-4-6 53-8-8
2-6-0 9-7-10 9-4-6 8 9-13 8-9-13 5-0-6 9-8-6
6x8 =
6.00 12
04 = 46 = 4x4 =
=
27 6 7 28 29 8 30 9 6x8
Scale = 1:98.9
ct 19 ___ 17 16 '"• 13 12
5x6 =
3x4 II 5x6 = 4x4 = 4x6 = 44 = 6x8 = 6x8 = 4x10 II
4.00 12
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TPI2014
CSI.
TC 0.92
BC 0.69
WB 0.84
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefl Lid
-0.21 16-17 >999 360
-0.42 16-17 >999 240
0.19 12 n/a n/a
0.31 17 >999 240
PLATES GRIP
MT20 2441190
Weight: 434 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc puriins,
BOT CHORD 2x6 SP No.2
except end verticals.
WEBS 2x4 SP No.3 *Except* BOT CHORD
Rigid ceiling directly applied or 4-3-14 oc bracing.
5-17,6-16: 2x4 SP M 30 WEBS
1 Row at micipt 3-19, 6-17, 6-16, 8-16, 8-15, 10-14
REACTIONS. (size) 2=0-7-10, 12=0-5-8
Max Horz 2=419(LC 11)
Max Uplift 2=-1569(LC 12), 12=-1338(LC 12)
Max Grav 2=2471(LC 17), 12=2167(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4234/3099, 3-5=-3385/2669, 5-6=-3153/2746, 6-8=-2589/2424, 8-9=-2530/2325,
9-10=-3193/2613, 10-11=-1112/922, 11-12=-2151/1756
BOT CHORD 2-21=-2866/3942, 19-21 =-286 6/3942, 17-19=-2106/3077, 16-17=-2274/3254,
15-16=-2059/2830, 14-15=-1936/2631, 13-14=-915/1091
WEBS 3-21=0/367, 3-19=-990/865, 5-19=-364/761, 5-17=-380/595, 6-17=-257/345,
6-16=-863/479, 8-16=-324/337, 8-15=-346/195, 9-15=-204/423, 9-14=-5271771,
10-14=-1201/1913,10-13=-2052/1889,11-13=-180212108
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; 8=45ft; L=54ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-9-4, Interior(1) 2-9-4 to 19-0-0, Exterior(2) 19-0-0 to
26-7-2, Interior(1) 26-7-2 to 41-8-0, Extedor(2) 41-8-0 to 49-3-2, Interior(1) 49-3-2 to 53-6-12 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
electronically Signed and
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Magid, Michael, PE
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
using a Digital Signature.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1569 lb uplift at joint 2 and 1338 lb uplift
Printed copies of this
at joint 12.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with li connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280418
76952
G7
Piggyback Base
3
1
Job Reference o tlonal
9-7-10
8.JJU S JUI LL LULU MI I eK Inaustnes, Inc. t-n Sep 11 14:2U:UU 2UZU rage 1
7-7-4
6x8 =
6.00 12 6x8
= 46 = 3x4 II 6x8 —
5 6 7 8 26 27 9 —
Scale = 1:103.4
zu its -- 17 - -- 15 - 14 '— 13 12
5x6 =
3x4 11 6x8 4x4 = 4x4 = 4x8 = 7x8 = 48 = Sx12 MT18HS 11
5x6 =
9-7-10 , 19-0-0 1 26-7-4 1 34-0-12 41.8-0 48A-8 55-4-8
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3
SPACING-
2-0-0
CSI.
DEFL.
in (loc) Udefl Lid
PLATES GRIP
Plate Grip DOL
1.25
TC 0.91
Vert(LL)
-0.21 17-18 >999 360
MT20 244/190
Lumber DOL
1.25
BC 0.71
Vert(CT)
-0.41 15-17 >999 240
MT18HS 244/190
Rep Stress Incr
YES
WB 0.88
Horz(CT)
0.15 12 n/a n/a
Code FBC20171TP12014
Matrix -MS
Wind(LL)
0.32 17 >999 240
Weight: 441 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 4-3-5 oc bracing.
WEBS
1 Row at midpt 3-18, 5-17, 6-17, 6-15, 8-15, 9-15, 9-14,
11-13
REACTIONS. (size) 2=0-7-10, 12=0-5-6
Max Hors 2=443(LC 11)
Max Uplift 2=-1614(LC 12), 12=-1377(LC 12)
Max Grav 2=2564(LC 17), 12=2383(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4431/3225, 3-5=-3580/2794, 5-6=3399/2888, 6-8=-3136/2761, 8-9=-3136/2761,
9-10=-2908/2387, 10-11=-2660/2010, 11-12=-2315/1822
BOT CHORD 2-20=-2922/4133, 18-20=-2922/4133, 17-18=-2158/3266, 15-17=-2356/3514,
14-15=-1684/2488,13-14=-1673/2290
WEBS 3-20=0/367, 3-18=-992/869, 5-18=-369/743, 5-17=-463/730, 6-17=-389/412,
6-15=4331209, 8-15=480/582, 9-15=-883/1236, 10-14=-163/469, 10-13=-759/757,
11-13=-1780/2433
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=55ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 2-11-4, Interior(1) 2-11-4 to 19-0-0, Exterior(2) 19-0-0
to 26-7-4, Interior(1) 26-7-4 to 41-8-0, Extedor(2) 41-8-0 to 49-6-0, Interior(1) 49-6-0 to 55-2-12 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1614 lb uplift at joint 2 and 1377 lb uplift
at joint 12.
0
N
O
N
f�
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overalls
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280419
76952
GB
Piggyback Base
2
1
Job Reference o tlonal
. ..... , �� ��� , �� o.33U s 3ul zz zuzu rot I eK Inous,nes, mc. hn sap 11 14:2U:U3 2U2u Page 1
ID:mis?TWUG3iZ?eE,yY9QLybykl5J-XC4mm289OQ1 asHPwlhWo9gbHCEZNC3k9SNVgUtyegoQ
-2-6-0 , 9-7-10 19-M 26-7-4 34-0-12 41-8-0 47-4-2 53-3-12
2 6-0 9-7-16 9-4-6 7-7-4 7.5-8 7-7.4 5 8-2 5-11-10
Scale: 1/8'=l'
6x8 =
6.00 12
3x4 II 4x6 = 4x4 = 6x8 =
6 7 278 28 9
N
O
N
C
CI 19 -- -- 17 -- 16 -- "- 14 -' 13 12
5x6 —_ 3x4 II 6x8 = 4x4 = 4x8 = 4x4 = 4x6 = 4x4 = 4x5 = 4x10 II
4x6 =
34-0-12
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017frP12014
CSI.
TC 0.86
BC 0.67
WB 0.86
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefl Ud
-0.20 17-19 >999 360
-0.39 19-21 >999 240
0.13 12 n/a n/a
0.30 17 >999 240
PLATES GRIP
MT20 2441190
Weight: 432 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 cc purlins,
BOT CHORD 2x6 SP No.2
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-4-0 cc bracing.
WEBS
1 Row at midpt 3-19, 5-17, 6-17, 8-16, 9-16, 9-14, 11-13
REACTIONS. (size) 2=0-7-10, 12=0-3-8
Max Horz 2=413(LC 11)
Max Uplift 2=-1559(LC 12), 12=-1329(LC 12)
Max Grav 2=2475(LC 17), 12=2291(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4244/3069, 3-5=-3392/2640, 5-6=-3161/2696, 6-8=-3161/2696, 8-9=-2882/2525,
9-10=-2483/2075, 10-11=-2045/1579, 11-12=-2234/1768
BOT CHORD 2-21=-2853/3948, 19-21=-2853/3948, 17-19=-2094/3080, 16-17=-2067/2979,
14-16=-1467/2143, 13-14=-1294/1754
WEBS 3-21=0/370, 3-19=-993/864, 5-19=-368/747, 5-17=-369/601, 6-17=-472/551,
8-17=-282/458, 8-16=-820/813, 9-16=-973/1356, 9-14=-346/251,10-14=-289/725,
10-13=-1012/914, 11-13=-154312091
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=53ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -2-7-4 to 2-8-12, Interior(1) 2-8-12 to 19-0-0, Exterior(2) 19-0-0
to 26-7-4, Interior(1) 26-7-4 to 41-8-0, Exterior(2) 41-8-0 to 49-2-8, Interior(1) 49-2-8 to 53-2-0 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This item has been
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically Signed and
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
fit between the bottom
sealed b Magid, Michael, PE
Y 9
will chord and any other members, with BCDL = I O.Opsf.
6) Provide mechanical connection (by- others) of truss to bearing plate capable of withstanding 1559 lb uplift at joint 2 and 1329 lb uplift
using a Digital Signature.
at joint 12.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall �•
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iwiTe k♦
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17rP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
T
T21280420
76952
GABLE
1
1
Job Reference (optional)
unarnoers Truss, inc., rort merce, rL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:06 2020 Page 1
ID:mis7T WUG3iZ7eEyY9QLybykl5J-ynlvO4A1 JLQ9jl7VQp4VnJDvuSkuPcSb8LkU4CyegoN
2-6-0 11-0-0 22-0-0 24 6 0
2-6-0 11-0-0 11-0-0 2-6-0
5x6 =
Scale = 1:45.3
I$
3x6 =
22-0-0
22-0-0
LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefi Lid PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) -0.02 13 n/r 120 MT20 244/190
TCDL 10.0 Lumber DOL 1.25 BC 0.11 Vert(CT) -0.03 13 n/r 90
BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) 0.01 12 n/a n/a
BCDL 10.0 Code FBC2017/TP12014 Matrix-S Weight: 147 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purling.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 22-0-0.
(lb) - Max Horz 2=-279(LC 10)
Max Uplift All uplift 100 lb or less at joints) 23,14 except 2=-433(LC 12), 20=-111(LC 12), 21=-133(LC 12),
22=-182(LC 12). 17=-111(LC 12), 16=-133(LC 12). 15=-182(LC 12), 12=-433(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 18, 20, 21, 22, 23, 17, 16, 15, 14 except 2=350(LC 1),
12=350(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-126/265, 5-6=-120/372, 6-7=-152/460, 7-8=-152/471, 8-9=-120/382, 9-10=-81/275
BOT CHORD 2-23=-64/256, 22-23=-64/256, 21-22=-64/256, 20-21=-64/256, 18-20=-64/256,
17-18=-64/256,16-17=-64/256, 15-16=-64/256,14-15=-64/256,12-14=-64/256
WEBS 6-20=-146/308, 5-21=132/251, 4-22=-146/289, 8-17=-137/309, 9-16=-135/250,
10-15=-145/289
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=2ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) -2-7-4 to 0-4-12, Exterior(2) 04-12 to 11-0-0, Corner(3) 11-0-0
to 14-0-0, Exterior(2) 14-0-0 to 24-7-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
This item has been
4) All plates are 2x3 MT20 unless otherwise indicated.
signed and
electronicallyMagid,
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
Sealed y g Michael, PE
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies of this
will fit between the bottom chord and any other members.
document are not considered
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 23, 14 except
signed and sealed and the
(jt=lb) 2=433, 20=111, 21=133, 22=182, 17=111, 16=133, 15=182, 12=433.
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. �
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not Vat
[��•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall � bullding design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
k♦
fs always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280421
76952
GEG
GABLE
1
1
Job Reference (optional)
.rs r runs, inc., ron rrerce, r� 6.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:13 2020 Page 1
I D: mis?T W U G3iZ?eEyYg QLybykl5J-F7gYsTGQgVI93gArKni8ZnO57G7 UYm3dlwwMglyegoG
2 6-0 13-0-0 26-0-0 28-6-0
' 2-6-0 13-0-0 13-M 2-6-0
6.00 12
3x6 =
5x6 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Vdefl
Lid
TCLL 20.0
Plate Grip DOL
1.25
TC 0.45
Vert(LL)
-0.02
17
n/r
120
TCDL 10.0
Lumber DOL
1.25
BC 0.11
Vert(CT)
-0.03
17
n/r
90
BCLL 0.0
Rep Stress Incr
YES
WB 0.16
Horz(CT)
0.01
16
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Scale = 1:51.4
PLATES GRIP
MT20 244/190
Weight: 181 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 26-0-0.
(Ib) - Max Horz 2=-328(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 29,18 except 2=-421(LC 12), 24=101(LC 12), 26=-146(LC 12),
27=-122(LC 12), 28=-183(LC 12), 22=-101(LC 12). 21=-146(LC 12), 20=-122(LC 12), 19=183(LC 12).
16=-321(LC 12) -
Max Grav All reactions 250 lb or less at joint(s) 23, 24, 26, 27, 28, 29, 22, 21, 20, 19, 18 except 2=350(LC
1). 16=350(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 6-7=-140/332, 7-8=-144/444,8-9=-175/528, 9-10=-175/539, 10-11=-144/455,
11-12=-105/342 -
BOT CHORD 2-29=-79/286, 28-29=-79/286,27-28=-79/286, 26-27=-79/286,24-26=-79/286,
23-24=-79/286, 22-23=-79/286, 21-22=-79/286, 20-21=-79/286, 19-20=-79/286,
18-19=-79/286, 16-18=-79/286
WEBS 8-24=-148/293,7-26=-136/258,4-28=-148/290, 10-22=-137/294,11-21=-140/258,
14-19=-147/290
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=26ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -2-7-4 to 0-4-12, Exterior(2) 0-4-12 to 13-0-0, Comer(3) 13-0-0
to 16-0-0, Extedor(2) 16-0-0 to 28-7-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
This item has been
grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
electronically signed and
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
Sealed by Magid, Michael, PE
4) All plates are 2x3 MT20 unless otherwise indicated.
using a Digital Signature.
5) Gable requires continuous bottom chord bearing.
Printed copies of this
6) Gable studs spaced at 2-0-0 oc.
document are not Considered
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
SI g
signed and sealed and the
8) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
Signature must be Verified
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 18 except
On any electronic copies.
Qt=lb) 2=421, 24=101, 26=146, 27=122, 28=183, 22=101, 21=146, 20=122, 19=183, 16=421.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall H V
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIf Quality Criteria, DSB-69 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa. FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLET21280422
TGrEM
76952
GABLE
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
2-"
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:14 2020 Page 1
Scale=1:32.6
5x6 =
Im
0
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.48
TCDL
10.0
Lumber DOL
1.25
BC 0.11
BCLL
0.0
Rep Stress Incr
YES
WB 0.11
BCDL
10.0
Code FBC2017/TPI2014
Matrix-S
DEFL, in (loc) Udell Lid PLATES GRIP
Vert(LL) -0.02 9 n/r 120 MT20 244/190
Vert(CT) -0.03 9 n/r 96
Horz(CT) 0.00 8 n/a n/a
Weight: 92 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4'SPNo.3
REACTIONS. All bearings 14-8-0.
(lb) - Max Horz 2=-204(LC 10)
Max Uplift All uplift 100 lb or less atjoint(s) 14, 10 except 2=-449(LC 12), 8=-449(LC 12), 13=-170(LC 12),
11=-170(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 12, 13, 14, 11, 10 except 2=352(LC 1), 8=352(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-116/352, 5-6=-117/365
WEBS 4-13=-149/353, 3-14=-225/254, 6-11=-144/354, 7-10=-226/255
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -2-7-4 to 0-4-12, Exterior(2) 04-12 to 7-4-0, Comer(3) 74-0 to
10-4-0, Exterior(2) 10-4-0 to 17-3-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSUTPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members,
electronically signed and
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 14, 10 except
2=449, 8=449, 13=170,11=170.
sealed by Magid, Michael, PE
(jt=lb)
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING-Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall /g�-
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iViiT®k-
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21260423
76952
GR7
Monopitch Girder
1
n
L•
Job Reference optional)
unamoers Truse, inc., Fort Fierce, rr- 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:17 2020 Page 1
I D:m I s?TW UG3iZ?eEyY9QLybykl5J-7vw3i rJxEobXRTdZdn4kdAsGtOsUYeDgYuzz3yegoC
3-6-0 7-0-0
3-6-0 3-6-0
3x4 =
3xB II `" 4x5
HUS26
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.12
TCDL
10.0
Lumber DOL
1.25
BC 0.47
BCLL
0.0
Rep Stress Incr
NO
WB 0.32
BCDL
10.0
Code FBC2017/TP12014
Matrix -MP
7-0-0
DEFL. in (loc) I/defl Ud PLATES GRIP
Vert(LL) 0.02 4-5 >999 240 MT20 244/190
Vert(CT) -0.02 4-5 >999 240
Horz(CT) 0.01 4 n/a n/a
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (size) 1=0-7-10, 4=Mechanical
Max Horz 1=220(LC 8)
Max Uplift 1=-918(LC 8), 4=-1041(LC 8)
Max Grav 1=1549(LC 1), 4=1552(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1986/1143
BOT CHORD 1-5=-1190/1767, 4-5=-1190/1767
WEBS 2-5=-996/1667, 2-4=-2039/1374
Scale=1:24.6
Weight: 95 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated.
3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf: BCDL=3.Opsf, h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=918, 4=1041.
8) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails Into Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-4-12
from the left end to 54-12 to connect truss(es) to front face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-60, 4-6=-20
Concentrated Loads (lb)
Vert: 5=-851 (F) 9=-851(F) 10=-851(F)
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiT®k♦
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-99 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
GRB
Half Hip Girder
13
[RIKIVIELVILLET2128076952
ob Reference O Clonal
ID:mis?TWUG3iZ?eEyY9QLybykl5J-aCt v—WLsdl7bnVkZxxZxhlALshhomNXRYDxPGyeeYR
2-0 6 6-9-0 11-3-14 15-10-12 20-5-10 2% -4
2-0.6 4-B 10 4-6-14 4.6-14 4-6-14 4-8-10
6.00 12 7x8 =
6x8 i
4x4 = 3x4 = 4x6 = 45 = 6x8 = 3x4 II
17 3 18 4 5 19 6 7 8
1
9n
91
99
97
24 9r. 9n
97 9n
19
90 1n
31 99 v9 9n
35
10 w Y w it iu 9
6x10 II 10x10 = HUS26 10x10 —_HUS26 HUS26 6x8 = HUS26 6x8 = HUS26 10x10 = HUS26 7x10 —
HUS26 Special HUS26 Special Special 7x8 = Special HUS26 Special HUS26 Special HUS26
Special Special HUS26 Special Special Special
JUS24
2-0-6 6-9-0 11-3-14 15-10-12 20-5-10 25-2-2 25- -4
2-0-6 4-8-10 4-6-14 4-6-14 4-6-14 4-8-7 0-0-3
Plate Offsets (X,Y)— [1:0.4-0,0-2-0], [2:0-6-4,0-3-8], [7:0-3-8,0-3-0], [9:0-4-12,0-4-12], [10:0-3-8,0-5-0], [11:0-3-4,0.4-8], [13:0-3-8,04-12], [14:0-3-8,0-5-0], [15:0-3-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
0.21 11-13
>999
240
TCDL 10.0
Lumber DOL
1.25
BC 0.45
Vert(CT)
-0.24 11-13
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.64
Horz(CT)
0.05 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x6 SP 240OF 2.0E
WEBS 2x4 SP M 30 'Except* BOT CHORD
8-9,1-16: 2x6 SP No.2
REACTIONS. (lb/size) 9=13047/0-5-3, 16=12443/0-7-10
Max Horz 16=60(LC 8)
Max Uplift 9=-8922(LC 5), '16=8311(LC 4)
FORCES. (lb) -Max., Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4523/3026, 2-17=-10447/7056, 3-17=-10447/7056, 3-18=-13170/8891,
4-18=-13170/8891,4-5=-12332/8374,5-19=-12332/8374,6-19=-12332/8374,
6-7=-8045/5502, 1-16=-12486/8331
BOT CHORD 15-21=-2539/3730, 21-22=-2539/3730, 22-23=-2539/3730, 23-24=-2539/3730,
14-24=-2539/3730,14-25=-7056/10447,25-26=-7056/10447,26-27=-7056/10447,
27-28=-7056/10447, 13-28=-7056/10447, 12-13=-8891/13170, 12-29=-8891/13170,
29-30=-8891/13170, 30-31=-8891/13170, 11-31=-8891/13170, 11-32=-8374/12332,
32-33=-8374/12332, 33-34=8374/12332, 34-35=-8374/12332, 10-35=-8374/12332,
10-36=-5502/8045, 36-37=-5502/8045, 37-38=-5502/8045, 38-39=-5502/8045,
9-39=-5502/8045
WEBS 2-15=-6770/4631, 2-14=-7503/11117, 3-14=-4006/2822, 3-13=-3147/4599,
4-13=-733/958, 4-11 =-1 415/935, 6-11=-3737/5598, 6-10=-7240/4883,
7-10=-7204/10707, 7-9=-13536/9256. 1 -1 5=-7236/10824
Scale = 1:52.2
PLATES GRIP
MT20 244/190
Weight: 743 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purling,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
"Special" indicates special hanger(s) or other
connection device(s) required at location(s)
shown. The design/selection of such special
connection device(s) is the responsibility of
others. This applies to all applicable truss
designs in this job.
NOTES- Continued on page 2
1) 3-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 Do.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section.
Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=25ft; eave=4ft;
Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0
wide will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8922 lb uplift at joint 9 and 8311 lb
uplift at joint 16.
8) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
SPnfPmhar 11 909f1
=11=�iG+iiORi+iR6N0Fi�6R^`..-:3"�'.^-'.--.-.,�7r.�0=GORR6Gti[R1SS(®gjltOli{URi4a08Tt3pUOtt6nNShOF
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design, Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 quality Cr/terla, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty1ply
76952
GRB
Half HIp Girder
1
J
FERIKIMELVILLET21280424
Reference (optional)
�um p� —., . ^_. —, 5.a3U s JUI 22 2U2U MiTeK Industries, Inc. Fri Sep 11 17:53:39 2020 Page 2
NOTES-
ID:mis7TWUG3iZ7eEyY9QLybykl5J-aCt v_WLsdl7bnVkZxxZxhlALshhomNXRYDxPFyeeYR
9) Use USP JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent at 11-6-12 from the left end to connect truss(es) to back face of bottom chord.
10) Fill all nail holes where hanger is in contact with lumber.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 593 lb down and 533 lb up at 1-8-12, 593 lb down and 533 lb up
at 3-8-12, 593 lb down and 533 lb up at 5-8-12, 593 lb down and 533 lb up at 7-6-12, 593 lb down and 533 lb up at 9-6-12, 593 lb down and 533 lb up at 13-6-12,
593 lb down and 533 lb up at 15-6-12, 593 lb down and 533 lb up at 17-6-12, 593 lb down and 533 lb up at 19-6-12, and 593 lb down and 533 lb up at 21-6-12,
and 593 lb down and 533 Ito up at 23-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-2=-60, 2-8=-60, 9-16=-20
Concentrated Loads (lb)
Vert: 12=1 367(F) 15=-1373(F)13=-592(B)11=-1367(F)20=-592(B)21=-592(B)22=-1360(F)23=-592(B)24=-1367(F)25=-592(B)26=-1367(F)27=-592(B)
28=-1367(F) 29=-592(B) 30=-1367(F) 31=-592(B) 32=-592(B) 33=1367(F) 34=-592(B) 35=1367(F) 36=-592(B) 37=1367(F) 38=-592(B) 39=1368(F)
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. '-;�•
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall p� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280425
76952
GRC
Piggyback Base Girder
1
Job Reference o floral
• • �• • • •�• o.ddu s Jul zz zuzu Nil I eK muusmes, Inc. r-n aep l 1 "14:ZU:Z4 Zulu rage i
ID:mis?TWUG3iZ?eE,yY9QLybykl5J-QFriAEOK4thbtW VzUbPjW6zOHihidYXFH85Rj9yego5
3-6-4 9-0-2 14-4-4 19-8-6 25-2-4
3-6-4 5-5-14 54-2 54-2 5-5-14
Scale = 1:54.1
3x4 =
6.00 12 5x8 =
3x4 = 4x6 = 5x8 = 3x4 11
2 15 3 16 4 175 6 18 7
5x6
ED
i
1
�o �n
�� �� �•a
n. .. 25
14 1d IG 7u -- 9 -- - -- 8
4x10 II 10x10 —HUS26 HUS26 6x8 = 5x6 = 6x8 —_ HUS26 7x8 —_ HUS26 HUS26 7x6 —
HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26
)-Q-3 3-6-4 9-0-2 14-4-4 14-9-13 25-2d
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017frP12014
CSI.
TC 0.26
BC 0.84
WB 0.95
Matrix -MS.
DEFL. in (loc) Vdefl Ud
Vert(LL) 0.14 10-12 >999 240
Vert(CT) -0.18 10-12 >999 240
Horz(CT) 0.03 8 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 763 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x6 SP No.2 *Except*
except end verticals.
8-11: 2x6 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS.
1 Row at micipt 7-8
7-8,1-14: 2x6 SP No.2, 6-8: 2x4 SP M 30
REACTIONS. (size) 8=0-7-10, 14=0-5-1
Max Horz 14=108(LC 8)
Max Uplift 8=-5447(LC 5), 14=-5528(LC 8)
Max Grav 8=8854(LC 1), 14=9471(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=4293/2532, 2-3=-7124/4274, 3-4=7562/4555, 4-6=-5295/3230, 1-14=-8544/5017
BOT CHORD 12-13=-2260/3709, 10-12=-427417124, 9-10=455517562, 8-9=-3230/5295
WEBS 2-13=-3093/1921, 2-12=-3495/5900, 3-12=-980/744, 3-10=-558/778, 4-10=-1715/2997,
4-9=-3978/2371, 6-9=-4296/7292, 6-8=-9264/5648, 1-13=-4351/7459
NOTES-
1) 3-ply truss to be connected together with 10d (0.131 "xY) nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 cc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
This Item has been
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=25ft; eave=4ft; Cat.
electronically signed and
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
Sealed by Magid, Michael, PE
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies of this
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
document are not considered
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
8=5447, 14=5528.
signed and sealed and the
9) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 cc max. starting at 1-1-8 from
signature must be verified
the left end to 23-1-8 to connect truss(es) to front face of bottom chord.
on any electronic copies.
10) Fill all nail holes where hanger is in contact with lumber.
Michael S. Magid PE No.53681
LOAD CASE(S) Standard
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Continued on page 2
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall p q�`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iVliTe k•
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
Puss
T21280425
76952
RC
Piggyback Base Girder
1
Job Reference (optional)
cnamoers truss, Inc., Tort Tierce, t-L
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:24 2020 Page 2
ID:mis?TWUG3iZ?eEyY9QLybykl5J-QFriAEOK4thbtW VzUbPjW6zOHihidYXFH85Rjgyego5
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-60, 2-7=-60, 8-14=-20
Concentrated Loads (lb)
Vert: 12=-1360(F)19=-1361(F)20=-1360(F)21=-1360(F)23=-1360(F)24=-1360(F)26=-1360(F)27=-1360(F)28=-1360(F)29=-1360(F)30=-1367(F)32=-1374(F)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall r
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/7P11 Quality Criteria, DSB-89 and BCS/Building Component 6904 Parke East Blvd.
Sarefylntormadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 '
Job
Truss Type
Qty
ERIK MELVILLE
FGruss
T21280426
76952
HALF HIP GIRDER
]Ply
1
1
Job Reference o tional
"••'-•••""•" •,`"��, ••,"•, , �,• , ,"w, , o.Jau s JUI zz zvAu Ivll I or. inausmes, Inc. t-n Sep 11 14:zu:za zuzu rage i
ID:m Is?T W U G3iZ?eEyY9QLybyklSJ-MdzTbvQacUxJ 6gfLbORBbX2DPW T85SuYkS aYo2yego3
2-6-0 5 0-0 8-3-14 11-7-13 17-8-4' 23 6-15 29-5-9 3510
2-0 0 5 0-0 3-3-15 3-3 15 6-0-7 5.10-11 5 10-11 6 0-7
5x8 =
3x4 II 4x8 = 48 = 4x4 =
6.00 12 3 21 22 23 244 25 26 275 28 6 297 30 31
Scale: 3/16"=1'
40 = 6x8 =
832 33 34 35 9
I- '- - 4o 40 4`J ou3x6 11
4x5 - 3x4 II 3x6 = 5x10 = 3x4 = 4x6 = 3x4 = 3x8 =
11-7-13
35-6-0
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.80
BC 0.45
WB 0.96
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) Vdefl Lid
0.30 12-14 >938 240
-0.22 12-14 >999 240
-0.06 10 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 212 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 4-4-11 oc bracing.
WEBS
1 Row at midpt 3-15, 5-15, 7-14, 9-11
REACTIONS. (size) 10=0-5-8, 2=0-7-10, 15=0-7-10
Max Horz 2=291(LC 8)
Max Uplift 10=-1571(LC 5), 2=-622(LC 8), 15=-3277(LC 8)
Max Grav 10=1317(LC 18), 2=386(LC 1), 15=2672(LC 1)
FORCES. (lb) -Mai. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=127/416, 3-4=-1632/1403, 4-5=-1632/1403, 5-7=-1147/1305, 7-8=-2296/2652,
8-9=-2001/2346, 9-10=-1217/1438
BOT CHORD 2-17=-373/66,15-17=-396/84,14-15=-1305/1147,12-14=-2652/2296,11-12=-2346/2001
WEBS 3-17=-492/355, 3-15=-1560/2113,4-15=-678/752, 5-15=-2806/3214, 5-14=830/773,
7-14=-1273/1491,8-12=-338/326,8-11=-736/828,9-11=-2521/2155
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
This item has been
10=1571, 2=622,15=3277.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 163 lb down and 344 lb up at
electronically signed and
5-0-0, 87 lb down and 160 lb up at 7-0-12, 87 lb down and 160 lb up at 9-0-12, 87 lb down and 160 lb up at 11-0-12, 87 lb down
led by Magid,
seagid, Michael, PE
and 160 lb up at 13-0-12, 87 lb down and 160 lb up at 15-0-12, 87 lb down and 160 lb up at 17-0-12, 87 lb down and 160 lb up at
using a Digital Signature.
19-0-12, 87 lb down and 160 lb up at 21-0-12, 87 lb down and 160 lb up at 23-0-12, 87 lb down and 160 lb up at 25-0-12, 87 lb
Printed copies of this
down and 160 lb up at 27-0-12, 87 lb down and 160 lb up at 29-0-12, 87 lb down and 160 lb up at 31-0-12, and 98 lb down and 218
document are not considered
lb up at 32-6-12, and 98 lb down and 215 lb up at 34-6-12 on top chord, and 350 lb down and 233 lb up at 5-0-0. 37 lb down and
47
signed and sealed and the
g
lb up at 7-0-12, 37 lb down and 47 lb up at 9-0-12, 37 lb down and 56 lb up at 11-0-12, 37 lb down and 93 lb up at 13-0-12, 37
lb down and 93 lb up at 15-0-12, 37 lb down and 93 lb up at 17-0-12, 37 lb down and 93 lb up at 19-0-12, 37 lb down and 93 lb up
signature must be verified
at 21-0-12, 37 lb down and 93 lb up at 23-0-12, 37 lb down and 93 lb up at 25-0-12, 37 lb down and 93 lb up at 27-0-12, 37 lb
on any electronic copies.
down and 93 lb up at 29-0-12, 37 lb down and 93 lb up at 31-0-12, and 40 lb down and 103 lb up at 32-6-12, and 44 lb down and
Michael S. Magid PE No.53681
103 lb up at 34-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
MiTek USA, Inc. FL Cert 6634
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
6904 Parke East Blvd. Tampa FL 33610
Date:
LOADCASE(S) Standard
September11,2020
Continued on page 2
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall nIY1�"
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing l;Tek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
ERIK MELVILLET21280426
76952
GRD
HALF HIP GIRDER
�QtyT
11
Job Reference (optional)
L,namoers I russ, mc., con Merce, t-L 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:26 2020 Page 2
ID:mis?TWUG3iZ?eEyY9QLybykl5J-MdzTbvQacUxJ6gfLbORBbX2DP WT85SuYkSaYo2yego3
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-60, 3-9=-60, 10-18=-20
Concentrated Loads (lb)
Vert: 3=-111(F) 6=-58(F) 17=-43(F) 21=-58(F) 23=-58(F) 24=-58(F) 25=-58(F) 26=-58(F) 27=-58(F) 28=-58(F) 29=-58(F)30=-58(F) 31=-58(F) 32=-58(F) 33=-58(F)
34=-90(F) 35=-96(F) 36=-18(F) 37=-18(F) 38=-18(F) 39=-18(F)40=-18(F) 41=-18(F) 42=-1 8(F) 43=-1 8(F) 44=-18(F) 45=-1 8(F) 46=-1 8(F) 47=-1 8(F) 48=-18(F)
49=-27(F) 50=-29(F)
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280427
76952
GRE
HALF HIP GIRDER
1
1
Job Reference (optional)
"••.... ... •� . • . • �� • •���a. �- O.OJV s Jul ZZ ZUZU Iwl r OK Inuustnes, Inc. rn aep l l l4:Zu:Z`J Zulu rage i
ID:mis1T W UG3iZ7eEyY9QLybykl5J-nCebDxS SuPJu_HOwG9_uD9gjvjMOsL_RQoCONyegcO
2-6-0 5-0-0 10-4-3 15-6-10 20-9-0 25-11-7 31-310
2 6-0 5-0-0 5-0-3 5-2-7 5 2-7 5 2-7 5-0-3
Scale=1:57.2
7x8 MT18HS = 3x4 =
3x4 = 5x8 MT18HS = 4x5 = 4x10 = 3x4 11
6.00 12 3 20 21 22 4 23 24 256 6 26 727 28 29 8 30 31 329
5x8 = 3x4 II 4x6 - 7x8 =-- -_ 3x4 =_-4x5 =_ .7x8 =
3x4 =
5-0-0 10-4-3 15-6-10 20-9-0 1 25-11-7 31-3-10
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TP12014
CSI.
TC 0.84
BC 0.98
WB 0.72
Matrix -MS
DEFL. in (loc) I/defi Lid
Vert(LL) 0.72 12-14 >521 240
Vert(CT) -0.46 14 >808 240
Horz(CT) -0.20 10 n/a We
PLATES
MT20
MT18HS
Weight: 215 lb
GRIP
244/190
2441190
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x6 SP 240OF 2.0E "Except* TOP CHORD
Structural wood sheathing directly applied or 3-10-14 oc purlins,
1-3: 2x6 SP No.2
except end verticals.
BOT CHORD 2x6 SP No.2 BOT CHORD
Rigid ceiling directly applied or 2-7-2 oc bracing.
WEBS 2x4 SP No.3 *Except* WEBS
1 Row at midpt 3-15, 8-10
3-15,4-14,5-12,7-11,8-10: 2x4 SP M 30
REACTIONS. (size) 10=0-7-10, 2=0-7-10
Max Horz 2=291(LC 32)
Max Uplift 10=-2569(LC 5), 2=-2659(LC 8)
Max Gram 10=1887(LC 1),2=1924(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3234/4410, 3-4=-4724/6503, 4-5=-5303/7242, 5-7=-4740/6445, 7-8=-3020/4100,
9-10=-243/285
BOT CHORD 2-16=-3966/2810, 15-16=-3984/2815, 14-1 5=-6503/4724, 12-14=-7242/5303,
11-12=-6445/4740, 10-11=4100/3020
WEBS 3-16=-348/255, 3-15=-2824/2158, 4-15=-805/925, 4-14=-866/660, 5-12=-635/916,
7-12=-736/543, 7-11 =-1 93912648, 8-11=-1551/1064, 8-10=-3356/4555
NOTES- Continued on page 2
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=31ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
This item has been
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
electronically signed and
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
fit between bottom
sealed by Magid, Michael, PE
will the chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
using a Digital Signature.
10=2569, 2=2659.
Printed copies of this
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 163 lb down and 342 lb up at
document are not considered
5-0-0, 87 lb down and 160 lb up at 7-0-12, 87 lb down and 160 lb up at 9-0-12, 87 lb down and 160 lb up at 11-0-12, 87 lb down
signed
red and sealed and the
and 160 lb up at 13-0-12, 87 lb down and 160 lb up at 15-0-12, 87 lb down and 160 lb up at 17-0-12, 87 lb down and 160 lb up at
19-0-12, 87 lb down and 160 lb up at 21-0-12, 87 lb down and 160 lb up at 23-0-12, 87 lb down and 160 lb up at 25-0-12, 87 lb
signature must be verified
down and 160 lb up at 27-0-12, and 87 lb down and 160 lb up at 29-0-12, and 86 lb down and 157 lb up at 30-6-12 on top chord,
on any electronic copies.
and 350 lb down and 233 lb up at 5-0-0, 37 lb down and 47 lb up at 7-0-12, 37 lb down and 47 lb up at 9-0-12, 37 lb down and 47
Michael S. Magid PE No.53681
lb up at 11-0-12, 37 lb down and 47 lb up at 13-0-12, 37 lb down and 47 lb up at 15-0-12, 37 lb down and 47 lb up at 17-0-12, 37
MiTek USA, Inc. FL Cart 6634
lb down and 47 lb up at 19-0-12, 37 lb down and 47 lb up at 21-0-12, 37 lb down and 47 lb up at 23-0-12, 37 lb down and 47 lb up
6904 Parke East Blvd. Tampa FL 33610
at 25-0-12, 37 lb down and 47 lb up at 27-0-12, and 37 lb down and 47 lb up at 29-0-12, and 45 lb down and 56 lb up at 30-6-12
Date:
on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
September I I
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
,2�20
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design into the overall�e
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M�Te �'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI! Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
s
Truss Type
City
Ply
ERIK MELVILLE
JG'R
T21280427
76952
HALF HIP GIRDER
1
1
Job Reference o tional
a ,iu r , run rl—, rL
t3.JUU s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:29 2020 Page 2
ID:m Is?T W U G3iZ?eEyY9QLybykl5J-nCebDxSSuPJu_HOwG9_uD9gjvjMOsL_RQoCONyegoO
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-60, 3-9=-60, 10-17=-20
Concentrated Loads (lb)
Vert: 3=-111(F) 6=-58(F) 16=-43(F) 20=-58(F) 22=-58(F) 23=-58(F) 24=-58(F) 25=-58(F) 26=-58(F) 27=-58(F) 28=-58(F) 29=-58(F)30=-58(F) 31=-58(F) 32=-70(F)
33=-18(F) 34=-18(F) 35=-18(F) 36=-18(F) 37=-18(F) 38=-18(F) 39=-18(F) 40=-18(F) 41=-18(F) 42=-18(F) 43=-18(F) 44=-18(F) 45=-22(F)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, OSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280428
76952
GRG
ROOF SPECIAL GIRDER
1
n
L
Job Reference (optional)
•- �• _w, o.00u s dw cc cucu rvu i ex muusmes, inc. rn aep -i -i-rwau:oz tuzu rage 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-BnKkrzULBKhSH7VyHYbrolKMwahVFvQ7N 1 s_hyegnz
c2-6-0 5 9-10 11-0-0 15-0-0 22 4-1 29 8-3 35-9-0 41-8-2 47-7-3 53-8-0 56-10-6 60.M 03-2-0
2 6 0' 5.9-10 1 -6 40-0 7 4-2 7.4-2 6 0-13 5-11-1 5 11-1 6-0-13 3 2 6 3-9-10 2-6-0
5x6 =
6.00 12 4
4x5 =
29
3x4 II
26 27 26
4x6 = 4x6 =
NAILED
NAILED
.. _ AIAn rn A,r =SvR = ArA —
25 43 44 P4 23 45
5x6 = NAILED 7x8 =
21 20 19
46 =
THD26-2 4X6 =
WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
5-9-10
Scale = 1:111.2
6x8 =
13 4x5
14
0
N
15 q a
I,
18 17
3x4 11 4x5 =
60-M
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Vdefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL)
-0.07 25-26 >999 360
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.25
Vert(CT)
-0.15 25-26 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.60
Horz(CT)
0.02 15 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL)
0.12 19-21 >999 240
Weight: 870 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
WEBS 2x4 SP No.3 *Except*
6-0-0 oc bracing: 23-25,22-23,21-22.
8-25: 2x4 SP M 30
REACTIONS. (size) 2=0-7-10, 23=0-7-10, 15=0-7-10
Max Hors 2=-342(LC 23)
Max Uplift 2=-987(LC 8), 23=-3939(LC 8), 15=-1619(LC 25)
Max Grav 2=1446(LC 29), 23=4739(LC 1), 15=1059(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2176/1193, 34=-1835/1106, 4-5=-1812/1118, 5-6=-2634/1556, 6-8=-2352/1263,
8-9=2129/2731, 9-11=-300/1366, 11-12=-737/2486, 12-13=-133712747,
13-14=-131212224, 14-15=-1423/2206
BOT CHORD 2-29=-817/2083, 28-29=-817/2083, 26-28=-1208/2699, 25-26=-1000/2430,
23-25=-2731/2484, 22-23=-1156/242, 21-22=-2131/737, 19-21=-2392/1337,
18-19=-1708/1161,17-18=-1733/1212,15-17=-173311212
WEBS 3-28=-520/349, 4-28=-718/1286, 5-28=-1481/854, 5-26=-520/682, 6-26=-1422/1323,
6-25=-833/795, 8-25=-3800/5595, 8-23=-3232/2408, 9-23=2314/2649, 9-22=-1141/940,
11-22=-1680/1728,11-21=-571/545,12-21=-733/623,13-19=-834/242,13-18=-320/266
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=61ft; eave=7ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general
handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood
Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner's authorized agent shall contract with a
qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the
permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or
bracing.
6) Provide adequate drainage to prevent water ponding.
7) All plates are 4x4 MT20 unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Continued on page 2
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September 11,2020
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�-
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
TGRG
T21280428
76952
ROOF SPECIAL GIRDER
1
Job Reference (optional)
I i—, mu., run rierce, rL t1.J3u S Jul 22 2UZU MI I eK Industries, Inc. Fri Sep 11 14:20:32 2020 Page 2
NOTES-
ID:mis7TW UG31Z7eEyY9QLybykl5J-BnKkrzULBKhSrl7VyHYbrolKMwahVFvQ7N1 s_hyegnz
9) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and
any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb) 2=987, 23=3939, 15=1619.
11) Use USP THD26-2 (With 18-16d nails into Girder & 12-1 Od nails into Truss) or equivalent at 22-1-8 from the left end to connect truss(es) to back face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
13) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 14=-60, 4-5=-60, 5-13=-60, 13-16=-60, 30-33=-20
Concentrated Loads (lb)
Vert: 25=-1532(B)38=-128(B)39=-128(B)40=-128(B)43=-40(B)44=-40(B)45=-40(B)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall q�*
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VliTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280429
76952
GRK
Roof Special Girder
1
1
Job Reference o tional
Chambers I russ, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:34 2020 Page 1
ID:m Is?T W UG3iZ?e EyY9QLybykl SJ-7ASUGf W bjyxA42Gu3ia3wDNhdk7bz8mjahW z3ayegnx
-211 5-8-7 6-11-9 9-1-12 11-0-0 15-9-6
2-6-0 3-6-4 2-2-3 1-3-3 2-2-3 1-10-4 4-9-6
Scale: 3/8-=l'
4.07 12
44 = 44 =
e G 22 5 23 6 24
— I I 3xb I I
LOADING (psi)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017lrP12014
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
SLIDER
Left 2x6 SP No.2 -H 2-6-0
REACTIONS. (size) 10=Mechanical, 2=0-7-10
Max Horz 2=181(LC 32)
Max Uplift 10=-494(LC 5). 2=-780(LC 8)
Max Grav 10=921(LC 37), 2=1069(LC 36)
15-9-6
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TC 0.40
Vert(LL)
0.3511-12 >540 240
MT20 244/190
BC 0.74
Vert(CT)-0.3611-12 >527 240
WB 0.64
Horz(CT)
0.02 2 n/a n/a
Matrix -MS
Weight: 85 lb FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-10-4 oc purlins,
except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-2 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=1393/788, 4-5=-1248/763, 5-6=-1169/738, 6-7=-1206/732, 7-8=-1349/800,
8-9=-2132/1279, 9-10=-820/494
BOT CHORD 2-15=-658/1151, 14-15=-662/1155, 13-14=-668/1167, 12-13=-667/1160,
11-12=-1306/2164
WEBS 7-12=-165/272,8-12=-1210/768, 8-11=-269/227, 9-11=-1235/2070
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
10=494, 2=780.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 378 lb down and 108 lb up at
3-64, 164 lb down and 113 lb up at 5-0-1, 87 lb down and 160 lb up at 6-4-0, 164 lb down and 113 lb up at 7-7-16, 241 lb down
and 165 lb up at 9-1-12, 111 lb down and 70 lb up at 12-8-12, and 203 lb down and 105 lb up at 144-12, and 169 lb down and 76
lb up at 15-7-10 on top chord, and 84 lb down and 11 lb up at 3-6-3. 38 lb down at 5-0-1, 37 lb down and 93 lb up at 6-4-0, 38 lb
down at 7-7-15, 43 lb down and 13 lb up at 9-1-12, 10 lb down and 7 lb up at 12-8-12, and 47 lb down and 16 lb up at 14-4-12,
and 49 lb down and 16 lb up at 15-7-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Continued on page 2
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall p �•
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280429
76952
GRK
Roof Special Girder
1
1
Job Reference (optional)
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:34 2020 Page 2
ID:mis?TW UG3iZ?eEyY9QLybyk]BJ-7ASUGfWbjyxA42Gu3ia3wDNhdk7bz8mjahWz3ayegnx
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 14=-60, 4-5=-60, 5-6=-60, 6-7=-60, 7-8=-60, 8-9=-60, 10-16=-20
Concentrated Loads (lb)
Vert: 9=22(F) 15=11(F) 12=-1(F) 22=-17(F) 23=-58(F) 24=-17(F) 26=32(F) 27=-6(F) 28=-18(F) 29=-6(F) 30=-3(F)
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280430
76952
GRL
Common Girder
1
Job Reference (optional)
b
run nor ca, rL o.,73U S Jul ZZ ZUZU MI I eK Inaustnes, Inc. rn Sep 11 14:ZU:36 2U20 Page 1
ID:mis?TWUG3iZ?eE_rY9QLybykl5J-3YZFhKXrFZCuJMQGB7cX?eT1 tYu3R3gO2??47Tyegnv
5-3-11 10-3-13 15-4-0 20 4 3 25-0-5 30-8-0
5-3-11 5-0-3 5-0-3 5-0-3 5-0-3 5-3-11
5x6 11
6.00 12
- -- 14 -_ ' . 13 _.. -.. 12 _, 11 __ ..,. 10 — ....
6x8
HUS26 3x4 11 HUS26 5x6 — HUS26 7xB = HUS26 Sx6 = HUS26 3x4 11 HUS26 6x8 =
=
HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26 HUS26
20-4-3
Scale = 1:63.1
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.41
BC 0.42
WB 0.61
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/defl Ud
-0.15 11-12 >999 360
-0.30 11-12 >999 240
0.09 9 n/a n/a
0.20 13-14 >999 240
PLATES GRIP
MT20 2441190
Weight: 443 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-8-2 oc purlins.
BOT CHORD 2x6 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 *Except*
5-12: 2x4 SP M 30
REACTIONS. (size) 1=0-7-10, 9=0-7-10
Max Horz 1=-336(LC 23)
Max Uplift 1=-3221(LC 8), 9=-2789(LC 8)
Max Grav 1=6043(LC 1), 9=5769(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-10649/5528, 2-4=-8847/4518, 4-5=-6796/3505, 5-6=-6796/3505, 6-8=-8819/4378,
8-9=-10513/5087
BOT CHORD 1-14=-4834/9435, 13-14=-4834/9435, 12-13=-3791/7883, 11-12=-366617858,
10-11=-4435/9310, 9-1 0=-4435/931 0
WEBS 5-12=-2845/5686, 6-12=-2690/1390, 6-11=-1105/2647, 8-11 =-1 688/884, 8-10=-541/1405,
4-12=-2726/1573, 4-13=-1301/2586, 2-13=-1802/1199, 2-14=-821/1505
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
This item has been
3) Unbalanced roof live loads have been considered for this design.
electronically Signed and
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=31ft; eave=4ft; Cat.
led b Magid, Michael, PE
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
seay g
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Using a Digital Signature.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed copies of this
will fit between the bottom chord and any other members.
document are not considered
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Ot=lb)
signed and sealed and the
1=3221,9=2789.
8) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-0-12
signature must be verified
from the left end to 28-10-12 to connect truss(es) to front face of bottom chord.
On any electronic Copies.
9) Fill all nail holes where hanger is in contact with lumber.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
LOAD CASE(S) Standard
6904 Parke East Blvd. Tampa FL 33610
Date:
Continued on page 2
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PIf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety lnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280430
76952
GRL
Common Girder
1
n
L
Job Reference o tlonal
i5
.a3u S Jul zz ZUZU MI I eK industries, Inc. Fri Sep 11 14:20:36 2020 Page 2
ID:mis?TWUG3iZ?eEyY9QLybyklSJ-3YZFhKXrFZCuJMQGB7cX?eTt tYu3R3g02??47Tyegnv
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=-60, 5-9=-60, 15-18=-20
Concentrated Loads (lb)
Vert:12=-615(F) 14=-641(F) 21=-641(F) 22=-641(F) 23=-641(F) 24=-641(F) 25=615(F) 26=-615(F) 27=-615(F) 28=-615(F) 29=-615(F) 30=-615(F) 31=-615(F)
32=-615(F) 33=-615(F)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Not
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
s
Truss Type
Qty
Ply
ERIK MELVILLE
Til
T21280431
76952
JACK -OPEN
4
1
Job Reference (optional)
s Truss, Inc., Pon Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:37 2020 Page 1
I D:m Is?T W UG3iZ?eEyY9 QLybykl5J-Yl7d ugYTOtKlxW?Tkg7mYr?COxH DAeYAGfkdgvyegnu
-2-6-0 1-0-0
2-6-0 1-0-0
i 1-0-0
i 1-0�
Scale = 1:11.8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
0.00
7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.23
Vert(CT)
0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Wind(LL)
-0.00
7
>999
240
Weight: 12 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=160(LC 12)
Max Uplift 3=-128(LC 1), 2=-601(LC 12), 4=-38(LC 1)
Max Grav 3=238(LC 12), 2=401(LC 1), 4=79(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 0-11-14 zone; porch left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
3=128, 2=601.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p at
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV IiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qry
Ply
ERIK MELVILLE
T21280432
76952
J3
JACK -OPEN
4
1
Job Reference optional)
s I russ, Inc., tort Fierce, t-L
8.330 s Jul 22 2020 MITek Industries, Inc. Fri Sep 11 14:20:38 2020 Page 1
I D:mis?T W UG3 iZ?eEyY9QLybykl5J-Oxh?6OZ6nASczgaflXf?43YN8Lb7v5oJVJU BCLyegnt
-2-6-0 3-0-0
2-6-0 3-0-0
N
r`
Scale = 1:16.8
3-0-0
3-0-0
Plate Offsets (X,Y)—
[2:Edge,0-0-11)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.43
Vert(LL)
0.01 4-7 >999 240
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.38
Vert(CT) -0.00 4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 19 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=222(LC 12)
Max Uplift 3=-60(LC 9), 2=464(LC 12), 4=-43(LC 9)
Max Grav 3=39(LC 17), 2=343(LC 1), 4=42(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -2-74 to 0-3-5, Interior(1) 0-3-5 to 2-11-4 zone; porch left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=464.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MITek USA, Inc. FL Cart 6034
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall HT BE'
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MIT®k*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
qty
Ply
ERIK MELVILLE
JTruss
T21280433
76952
JACK -OPEN ]29
1
Job Reference (optional)
s Truss, Inc., Fort fierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:38 2020 Page 1
ID:m I s?T W UG3iZ?e EyY9QLybykl5J-Oxh76OZ6nAScZgaflXf?43YN8LV7v5oJVJUBCLyegnt
-2-6-0 - 5-0-0
2-6-0 5-0-0
Scale = 1:21.7
5-0-0
5-0-0
Plate Offsets (X,Y)—
[2:0-0-0,0-0-31
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.43
Vert(LL) 0.10
4-7 >623 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.76
Vert(CT) -0.04
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.01
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 28 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=287(LC 12)
Max Uplift 3=-140(LC 12), 2=-495(LC 12), 4=-82(LC
9)
Max Grav 3=120(LC 17), 2=395(LC 1), 4=77(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exteriar(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 4-11-4 zone; porch left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 4 except at=lb)
3=140, 2=495.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
e604 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP/1 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
76952
J5A
JACK -OPEN
2
1
T21280434
Job Reference o tional
russ, rnu., run rierce, rL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:39 2020 Page 1
I D:m Is1T W U G3 iZ7e EyY9 QLybykl5J-U7FN JMakYUaTAp9rsFAEd G4XEIgNeY2SkzDkknyeg ns
5-0-0
Scale = 1:18.7
3x5 =
5.0-0
5-0-0
Plate Offsets (X,Y)—
[1:0-0-0,0-0-3)
LOADING (psf)
SPACING- 2-0-0
CSt.
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) 0.11
3-6 >548 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.83
Vert(CT) -0.04
3-6 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.02
2 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Weight: 21 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=0-7-10, 2=Mechanical, 3=Mechanical
Max Horz 1=159(LC 12)
Max Uplift 1=-189(LC 12), 2=-196(LC 12), 3=-90(LC 12)
Max Grav 1=198(LC 1), 2=150(LC 1), 3=80(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-11-4 zone; porch left and
right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
1=189, 2=196.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5119I2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280435
76952
J7
Jack -Open
3
1
Job Reference o tional
Russ, Inc., Fort Fierce, FL
2-6-0
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:39 2020 Page 1
I D:mis?TWUG3i2?eEyY9QLybykl5J-U7FNJMakYUaTAp9rsFAEdG4WzlsgeY2SkzDkknyegns
7-0-0
Scale=1:26.4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/clef!
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.55
Vert(LL)
-0.07
4-7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.68
Vert(CT)
-0.16
4-7
>527
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.02
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.08
4-7
>999
240
Weight: 36 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=351(LC 12)
Max Uplift 3=-197(LC 12). 2=-394(LC 12)
Max Grav 3=215(LC 17), 2=463(LC 1). 4=111(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 6-11-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Gt=lb)
3=197.2=394.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall p �•
building design, Bracing Indicated Is to prevent buckring of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek♦
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280436
76952
JA
Jack -Open
2
1
Job Reference (optional)
s Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:40 2020 Page 1
ID:mis?TWUG3iZ?eE_rY9QLybykl5J-yKplXibMJoiKozkl QyhT9Udd691YN?IcydzHGEyegnr
-2-7-4 4-7-14
2-7-4 4-7-14
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
-0.01
4-7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.25
Vert(CT)
-0.03
4-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
-0.02
4-7
>999
240
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=269(LC 12)
Max Uplift 3=-91(LC 12), 2=-398(LC 12)
Max Grav 3=120(LC 17), 2=394(LC 1), 4=71(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:20.4
0
v
N
PLATES GRIP
MT20 244/190
Weight: 27 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -2-8-7 to 1-6-7, Exterior(2) 1-6-7 to 4-7-2 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=398.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP/r Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280437
76952
JB
Jack -Open
4
1
Job Reference (optional)
unanrumb r rubs, rnc., Fur[ Pierce, n_
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:41 2020 Page 1
I D:ml s7T W UG3iZ7eEyY9QLybykl5J-Q W N8k2b_45q BQ7J EzgCi ihAnszbO6SYl B H irpgyegnq
-2-7-4 2-10-6
2-7-4. 2-10.6
Scale: 3/4"=1'
2-10.6
2-10-6
Plate Offsets (X,Y)—
[2:0-0-0,0-0-7)
LOADING (psf)
SPACING- 2-0-0
cSl.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.78
Vert(LL) 0.00
4-7 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.41
Vert(CT) -0.01
4-7 >999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.01
2 n/a n/a
BCDL 10.0
Code FBC2017lTPI2014
Matrix -MP
Wind(ILL) -0.01
4-7 >999 240
Weight: 20 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-10-6 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=214(LC 12)
Max Uplift 3=-36(LC 9), 2=-419(LC 12)
Max Grav 3=39(LC 17), 2=353(LC 1), 4=39(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3) -2-8-7 to 1-6-7, Exterior(2) 1-6-7 to 2-9-10 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
2=419.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�®
�a
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB•89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280438
76952
JC
Jack -Open
3
1
Job Reference (Optional)
s Truss, Inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:41 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-QWN8k2b_45gBQ7JEzgCiihAtNZes6SYIBHirpgyegnq
2�-0 2-1-13
2 6-0 2-1-13
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
Udefl
L/d
TCLL 20.0
Plate Grip'DOL
1.25
TC 0.43
Vert(LL)
0.00
7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.25
Vert(CT)
0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
-0.01
4-7
>999
240
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=195(LC 12)
Max Uplift 3=-12(LC 9), 2=-430(LC 12), 4=2(LC 1)
Max Grav 3=57(LC 12), 2=337(LC 1), 4=35(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:14.7
PLATES GRIP .
MT20 244/190
Weight: 17 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-1-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0,18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 2-1-1 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Gable studs spaced at 2-0-0 oc.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=430.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. SM912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall MiTek*
LL q� �
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IV I) 1T ®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
76952
JD
Jack -Open
1
1
T21280439
r:hnmh— T.— 1—r,.w
oo,.-..,, n
Job Reference (optional)
assu s Jul zz zozu Mi Iek industries, Inc. Fri Sep 11 14:20:42 2020 Page 1
1-8-0 ID:mis?TW UG3iZ?eEyY9QLybykl5J-uixWyOccgPy21 HtQXNjxFui8Eyl BrvnvQxSOL6yegnp
i
180
a nn
3x4 =
Scale = 1:10.4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. In
(loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
Vert(LL) -0.00
6 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.05
Vert(CT) -0.00
6 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL) 0.00
6 >999 240
Weight: 7 lb FT = 20%
LUMBER.
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 1-8-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=0-7-10, 2=Mechanical, 3=Mechanical
Max Horz 1=53(LC 12)
Max Uplift 1=-19(LC 12). 2=-60(LC 12), 3=-3(LC 12)
Max Grav, 1=66(LC 1), 2=57(LC 17), 3=26(LC 3)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 2, 3.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a buss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSIMP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information avallabie from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280440
76952
JE
Jack -Open
2
1
Job Reference (optional)
wamuers truss, inc., Pon Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:42 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-uixWyOccgPy21 HtOXNjxFui27y_9rvnvQxSOL6yegnp
-2-6.0 1-8-0
' 2-6-0 1-"
N
d
Scale = 1:13.5
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
0.00
7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.25
Vert(CT)
0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
3
nla
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
-0.00
4-7
>999
240
Weight: 15 lb FT = 20%
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-7-10, 4=Mechanical
Max Horz 2=181(LC 12)
Max Uplift 3=45(LC 1), 2=468(LC 12), 4=-12(LC 1)
Max Grav 3=106(LC 12), 2=345(LC 1), 4=45(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-8-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf, BCDL=3.Opsf, h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 1-7-14 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=468.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cen 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall�-
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PI1 Quality Criteria, DSB-69 and BCS/ Building Component 6904 Parke East Blvd.
Safety Informadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280441
76952
K
Roof Special
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:43 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-MvUu9kdEbj4vfRSc55EAn6FB6MGJaJ32fbBxtZyegno
2-1-10 6-4-0 9-0-0 14-6-6 1" 6
2-1-10 4-2-6 2 8.0 5-6-6 1-3-0
Scale=1:28.2
5x8 =
I�
0
3x4 11 6x8 =
3x4 = 3x4 II
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.54
BC 0.51
WB 0.25
Matrix -MS
DEFL. in
Vert(LL) -0.21
Vert(CT) -0.43
Horz(CT) 0.11
Wind(LL) 0.35
(loc) Udefl Ud
9-10 >8B7 360
9-10 >432 240
7 n/a n/a
9-10 >530 240
PLATES GRIP
MT20 244/190
Weight: 92 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-6-6 oc pudins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-3-3 oc bracing.
REACTIONS. (size) 1=0-7-10, 7=Mechanical
Max Horz 1=120(LC 12)
Max Uplift 1=-381(LC 12), 7=-419(LC 9)
Max Grav 1=625(LC 1), 7=625(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-859/727, 2-3=-1221/1023, 3-4=-1108/966, 4-5=-1074/900
BOT CHORD 1-13=-635/646, 11-12=-1247/1284, 10-11=-934/1103, 9-10=-584/679, 5-9=-114/251,
7-8=-336/367
WEBS 2-11=-316/317, 3-11=-269/371, 4-10=-289/349, 5-7=-932/854, 5-10=-327/409
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Intedor(1) 3-0-0 to 6-4-0, Extedor(2) 64-0 to
9-0-0, Interior(1) 9-0-0 to 15-7-10 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This item has been
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
electronically Signed and
1=381, 7=419.
sealed b y Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I192020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall �•
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
MELVILLET21280442
FERIK
76952
Kt
Roof Special
1
1Reference
(optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:44 2020 Page 1
ID:mis?TWUG3IZ?eEyY9QLybykl5J-g52GM3etMOCIHbl pfomPKJoPVmZDJglBtFxVP?yegnn
2-1-10 64-0 7-0-0 14-6.6 15-9.6
2-1-1do 4-2-6 0-8-0 1 7-6-6
12
3x4 II
3x4 =
4x6 =
6x8 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
I/deg
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.37
Vert(LL)
-0.07
9-10
>999
360
TCDL
10.0
Lumber DOL
1.25
BC 0.66
Vert(CT)
-0.17
9-10
>999
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.64
Horz(CT)
0.07
7
n/a
n/a
BCDL
10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.10 10-11
>999
240
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x4 SP M 30'ExcepV
5-8: 2x4 SP No.3 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (size) 1=Mechanical, 7=Mechanical
Max Horz 1=184(LC 12)
Max Uplift 1=-370(LC 12), 7=-471(LC 9)
Max Grav 1=625(LC 1), 7=625(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-835/634, 2-3=-1083/858, 3-4=-820/794, 4-5=-976/868, 6-7=-303/244
BOT CHORD 1-12=-654/626, 10-11=-1346/1302, 9-10=-353/388, 7-8=-280/291
WEBS 2-10=-394/462, 5-10=-543/620, 5-7=-967/931
Scale = 1:28.2
7x8 II 3x4 II
8 7
6x8 =
3x4 II
PLATES GRIP
MT20 244/190
Weight: 99 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 6-3-11 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-4-0, Exterior(2) 64-0 to
7-0-0, Interior(1) 7-0-0 to 15-7-10 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=370,7=471.
IQ
0
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
Nat
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280443
76952
K2
Half Hip
1
1
Job Reference (optional)
2-1-1
5x8 =
2x3 11
11
3x4 = 3x4 II
o—iju s JUI zz zuzu mi I eK Industries, Inc. eft sep 11 14:ZU:45 ZUZU Page 1
17
14-6-6
6x8 = 3x4 II
18 19 4 5
7 6
6x8 =
3x4 II
I9
0
Scale: 3/8'=1'
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TP12014
CSI.
TC 0.58
BC 0.97
WB 0.76
Matrix -MS
DEFL. in
Vert(LL) -0.09
Vert(CT) -0.19
Horz(CT) 0.09
Wind(LL) 0.19
(loc) Vdefi Ud
9-10 >999 360
9-10 >972 240
6 n/a n/a
9-10 >964 240
PLATES GRIP
MT20 244/190
Weight: 97 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 5-11-7 oc puriins,
BOT CHORD 2x4 SP M 30'Except*
except end verticals.
2-11,4-7: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 1=Mechanical, 6=Mechanical
Max Horz 1=248(LC 12)
Max Uplift 1=-355(LC 12), 6=-475(LC 9)
Max Grav 1=625(LC 1), 6=625(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=763/525, 2-3=912/713
BOT CHORD 1-11=-610/545, 9-10=-820/807, 8-9=-821/815, 4-8=-282/410
WEBS 3-9=-13/322, 3-8=-691/696, 4-6=-791/787
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf, h=20ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 7-8-0, Exterior(2) 7-8-0 to
11-10-15, Interior(1) 11-10-15 to 15-7-10 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This Item has been
6) Refer to girder(s) for truss to truss connections.
electronically Signed and
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=355,6=475.
sealed b Ma
y Id, Michael, PE g
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall'
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety lnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280444
76952
K3
Half Hip
1
1
Job Reference (optional)
�.��� a .+m cc tutu rvn i en n iuusmns, mc. rn oep i r 14:Lu:4o zuzu rage _i
4-10-6
Sx8 =
44 =3x4 II
3 17 18 19 4 5
Im
0
11 2x3 II
7
3x4 = 3x4 II 6
6x8 =
3x4 11
2-1-10 9-8-0 14-6-6 , 15-9-6
Scale = 1:35.8
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017IrP12014
CS1.
TC 0.78
BC 0.91
WB 0.58
Matrix -MS
DEFL. In
Vert(LL) -0.17
Vert(CT) -0.37
Horz(CT) -0.13
Wind(LL) 0.35
(loc) Udell Ud
9-10 >999 360
9-10 >504 240
6 n/a n/a
9-10 >537 240
PLATES
MT20
MT18HS
Weight: 101 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 4-4-14 oc purlins,
BOT CHORD 2x4 SP M 30'Except-
except end verticals.
2-11,4-7: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 8-1-12 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 1=Mechanical, 6=Mechanical
Max Horz 1=313(LC 12)
Max Uplift 1=-336(LC 12), 6=-452(LC 9)
Max Grav 1=630(LC 17), 6=625(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-737/458, 2-3=-737/503
BOT CHORD 1-11=-614/531, 9-10=-662/647, 8-9=-663/654, 4-8=-437/488
WEBS 3-9=27/345, 3-8=-730/737, 4-6=-552/545
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 9-8-0, Exterior(2) 9-8-0 to
13-10-15, Interior(1) 13-10-15 to 15-7-10 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically Signed and
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
sealed by Magid, Michael, PE
1=336, 6=452.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September 11,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5f19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall Not
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPN qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
l
Job
Truss
Truss Type
Qry
Ply
ERIK MELVILLE
T21280445
76952
K4
Half Hip
1
1
Job Reference (optional)
--•••-• -� � ••• • �•• • •�o.00u b dw cc zuzu Ivn i er, mousmes, Inc. rn oep I I vc.&u:4t zuzu rage 1
I D:mis7TWUG3iZ7eE,yY9QLybykl5J-FgkP75glfxaK82mOKwJ6yyQu9zVIW3OeZD99OKyegnk
2-1-10 7-0-0 11.8-0 14-6-6 15-9-6
Ti-10 4-10.6 4-8-0 2-10-6 1-3-0
5x8 =
4x4 = 3x4 II
4 19 5 6
Im 0
13 24 II 3x4 = 8
7
3x4 = 3x4 II
6x8 =
11-8-0
Scale = 1:39.7
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017frP12014
CS1.
TC 0.47
BC 0.99
WB 0.45
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft Lid
-0.07 11-12 >999 360
-0.15 11-12 >999 240
-0.08 7 n/a n/a
0.15 11-12 >999 240
PLATES GRIP
MT20 244/190
Weight: 119 Ib FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins,
BOT CHORD 2x4 SP M 30 -Except-
except end verticals.
2-13,5-8: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 1=Mechanical, 7=Mechanical
Max Horz 1=377(LC 12)
Max Uplift 1=-313(LC 12), 7=-467(LC 12)
Max Grav 1=633(LC 17), 7=629(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=772/401, 2-3=-1016/681, 3-4=464/324
BOT CHORD 1-13=-617/587, 11-12=-973/976, 10-11=-973/976, 9-10=-376/360, 5-9=-475/496
WEBS 3-10=-748/722,4-10=-353/472,4-9=-540/563, 5-7=-550/587
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-8-0, Extedor(2) 11-8-0 to
15-7-10 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
This Item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
electronically signed and
1=313, 7=467.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall my
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k♦
Is always required for stability and to prevent collapse with possible personal Injury andproperty damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
MELVILLET21280446
76952
K5
Half Hip
1
7PlyEFRIK
Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:48 2020 Page 1
I D:mis?TWUG3iZ?eEyY9QLybykl5J-jslnCRhNQFiBICLauegLU9y2zNrLFOfnotviYmyegnj
2-1-10 VIO-13 13-8-0 4 6-6 15-9-6
2-1-10 5-9-3 5-9-3 -10-6 1-3-0
i
4x6 =
6x8 = 3x4 11
5 6
12 2x3 II 8 7
3x4 = 3x4 II 6x8 =
3x5 =
I2
Scale = 1:45.4
2-1-10 7-10-13
14-M 3x15-� 6
2-1-10
6-7-9 1-3-0
Plate Offsets (X,Y)—
[2:0-1-12,0-0-14), [2:0-2-8,0-3-5), [11:0-0-0,0-1-12j
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.53
Vert(LL)
-0.09 10-11 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.96
Vert(CT)
-0.19 10-11 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 1.00
Horz(CT)
-0.09 7 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL)
0.19 10-11 >962 240
Weight: 112 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 5-11-3 oc purlins,
BOT CHORD 2x4 SP M 30 *Except*
except end verticals.
2-12,5-8: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 1=Mechanical, 7=Mechanical
Max Horz 1=441(LC 12)
Max Uplift 1=-286(LC 12), 7=-494(LC 12)
Max Grav 1=632(LC 17), 7=655(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-762/323, 2-3=-938/506
BOT CHORD 1-12=-606/582, 10-11=-870/916, 9-10=870/916, 5-9=-340/485
WEBS 3-10=-6/321, 3-9=-919/847, 5-7=-672/848
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-8-0, Extedor(2) 13-8-0 to
15-7-10 zone;C-C for members and farces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
This Item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
electronically signed and
1=286, 7=494.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 101II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Val'
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIKMELVILLE
T21280447
76952
K6
Half Hip
1
1
Job Reference (optional)
••�� • • o.00u s uui xc cuzu mi i ex mcusmes, Inc. rn sap itia:zu:4a tutu rage 1
ID:mis?TWUG3IZ?eEyY9QLybykl5J-B3s9Qni?BZg2NMwmRLLal NVFOnLb_sNxl XeG5Cyegni
7-11-10 15-8-0 1 -0 6
7-11-10 7-8-6 0-0 16
6.00 12 4
3x6 =
Scale = 1:46.9
4x4
7 12 3x6 =
B
4
0
N
6 5
3x4 = 3x4 = 3x4 II
LOADING (psQ
SPACING-
2-0-0
CSL
DEFL.
in
(loc)
Udefl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL)
-0.06
5-6
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.32
Vert(CT)
-0.13
5-6
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.91
Horz(CT)
-0.01
12
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.07
6-11
>999
240
LUMBER- BRACING -
TOP CHORD 2x6 SP No.2 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP M 30
REACTIONS. (size) 1=Mechanical, 12=Mechanical
Max Horz 1=501(LC 12)
Max Uplift 1=-265(LC 12), 12=-513(LC 12)
Max Grav 1=638(LC 17), 12=670(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=881/305, 4-7=337/474
BOT CHORD 1-6=-675/782
WEBS 6-7=711/783, 2-7=-767/655, 4-12=-671/553
PLATES GRIP
MT20 244/190
Weight: 115 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 8-8-5 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 15-7-2 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide
Will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=265, 12=513.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overalls
building design. Bracing Indicated is to prevent buckling of individual truss web end/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Jab
Truss
Truss Type
Ply
ERIK MELVILLE
jQty
T21280448
76952
K7
Monopitch
g
1
Job Reference (optional)
c.uaowsfs r Fuss, mc., Purr Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:50 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-fFQXd7idysyv7W Vy73spZa2QaBhjjRF4GBOpdfyegnh
8-0-1 16-0-6
8-0-1 8-0-5
6.00
3x6 =
Scale = 1:47.2
3x4 = 2x3 II
8-0-1
8-0-1
4x4 =
16.0-6
8-0-5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(lac) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Vert(LL)
-0.07
5-6 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.33
Vert(CT)
-0.14
5-6 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.42
Horz(CT)
-0.06
11 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.07
6-10 >999 240
Weight: 105 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 8-8-7 oc bracing.
OTHERS 2x4 SP No.3
WEBS
1 Row at midpt 2-5
REACTIONS. (size) 1=Mechanical, 11=Mechanical
Max Horz 1=501(LC 12)
Max Uplift 1=-265(LC 12), 11=-513(LC 12)
Max Grav 1=638(LC 17), 11=670(LC 17)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=880/304, 5-7=-345/484, 4-7=-345/484
BOT CHORD 1-6=-674/781, 5-6=674/781
WEBS 2-6=0/343, 2-5=-853/743, 4-11=-671/553
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 15-7-2 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=lb)
1=265,11=513.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
�Monopltch
T21280449
76952
K8
2
1
Job Reference o tlonal
cuss, Inc., tort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:50 2020 Page 1
ID:mis7TWUG3iZ7eEyY9QLybykl5J-fFQXd7idysyv7 W Vy73spZa2QaBhpRF4GBOpdfyegnh
8-0-1 16-0-6
8-0-1
4
Scale = 1:47.2
6.00 12
4x10
—
4x6
3x4 i
2
3
3x6 =
rn
m
12
LA 3x6 =
711
1
0
q
-6-•II
N
6
5
3x4 =
2x3 II
4x4 =
8-0-1
16-0-6
8-0-1
8-0-5
LOADING
(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Vdefi
Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.40
Vert(LL)
-0.07
5-6
>999
360
MT20 244/190
TCDL
10.0
Lumber DOL
1.25
BC 0.33
Vert(CT)
-0.14
5-6
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.42
Horz(CT)
-0.06
11
n/a
n/a
BCDL
10.0
Code FBC2017lrP12014
Matrix -MS
Wind(LL)
0.07
6-10
>999
240
Weight: 105 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD
2x6 SP No.2
TOP CHORD
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
BOT CHORD
OTHERS
2x4 SP No.3
WEBS
REACTIONS.
(size) 1=0-7-10, 11=Mechanical
Max Horz 1=501(LC 12)
Max Uplift 1=-265(LC 12). 11=-513(LC 12)
Max Grav 1=638(LC 17). 11 =670(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD
1-2=880/304, 5-7=-345/484, 4-7=-345/484
BOT CHORD
1-6=-674/781, 5-6=-674/781
WEBS
2-6=0/343, 2-5=-853/743, 4-11=-671/553
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 8-8-7 oc bracing.
1 Row at midpt 2-5
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 15-7-2 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except at=lb)
1=265,11=513.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/19/2020 BEFORE USE.
k® Design valid for use only with MiTeconnectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall,
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing NliTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see AMSIITP11 Quality Criteria, DS8.89 and BCS/ Building Component Blvd.
e East
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, 6904 Parkrk East
Job
Truss
Truss Type
cityPly
ERIK MELVILLE
T21280450
76952
KJ3
Diagonal Hip Girder
1
1
Job Reference o tional
tlAJu s JUI zz zuzu mi I eK Inaustnes, Inc. I-n Sep 11 14:2U:51 2U20 Page 1
ID:mis?T WUG3iZ?eEyY90Lybykl5J-7RzwrTjGjA5mcf49ZmO26oaclb5jS_ODUr7N95yegng
-2-9-3 1-11-3 3-10-6
2-9-3 1-11-3 1-11-3
Scale = 1:17.9
3-10-6
3-10-6
Plate Offsets (X,Y)—
[2:0-0-0,0-0-8)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL) -0.03
4-7 >999 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.09
Vert(CT) -0.03
4-7 >999 180
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.01
2 rile rile
BCDL 10.0
Code FBC2017[TP12014
Matrix -MP
Weight: 23 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-10-6 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-2, 4=Mechanical
Max Horz 2=238(LC 8)
Max Uplift 3=-43(LC 6), 2=401(LC 8)
Max Grav 3=229(LC 24), 2=372(LC 1), 4=83(LC 24)
FORCES. (lb) -Max. Comp.lMax. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except at --lb)
2=401.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 191 lb down and 120 lb up at
2-6-5, and 179 lb down and 66 lb up at 3-2-10 on top chord, and 36 lb down and 11 lb up at 2-6-5, and 33 lb down and 6 lb up at
3-2-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-60, 4-5=-20
Concentrated Loads (lb)
Vert: 8=37(B) 1 0=9(B) 11 =6(F)
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek9 connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
r
building design, Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280451
76952
KJ5
DIAGONAL HIP GIRDER
2
1
Job Reference (optional)
Fuss, inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:52 2020 Page 1
I D: m IS?TW UG3iZ?e EyYg QLybykl5J-bdXl2oku U U Dd EpeL7UvHf77kR_OpBO3N)VtwhXyeg of
-3-6-7 3.6-1 7-0-2
3-6-7 3-6-1 3-6-1
Scale = 1:21.2
I�
N
n
N
Plate Offsets (X,Y)—
[2:0-0-0,0-0-5)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.57
Vert(LL) -0.04
7-10 >999 240
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.29
Vert(CT) 0.02
7-10 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.21
Horz(CT) 0.01
2 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 44 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-10-7, 5=Mechanical
Max Horz 2=284(LC 8)
Max Uplift 4=-127(LC 8), 2=-792(LC 8), 5=221(LC 5)
Max Grav 4=138(LC 17), 2=732(LC 28), 5=225(LC 24)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-943/412
BOT CHORD 2-7=-372/698, 6-7=372/698
WEBS 3-6=-772/411
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (it=lb)
4=127, 2=792, 5=221.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 333 lb down and 213 lb up at
1-6-1, 333 lb down and 213 lb up at 1-6-1, and 136 lb down and 73 lb up at 4-4-0, and 136 lb down and 73 lb up at 4-4-0 on top
This item has been
chord, and 138 lb down and 67 lb up at 1-6-1, 138 lb down and 67 lb up at 1-6-1, and 11 lb down and 5 lb up at 4-4-0, and 11 lb
electronically signed and
down and 5 lb up at 4-4-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASES) loads
sealed b Magid, Michael, PE
SeaeY g
section, applied to the face of the truss are noted as front (F) or back (B).
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
document are not considered
Uniform Loads (plf)
Vert: 1-4=-60, 5-8=-20
signed and sealed and the
Concentrated Loads (Ib)
signature must be verified
Vert: 11=138(F=69, B=69) 13=73(F=36, B=36) 14=9(F=5, B=5)
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
lifiI
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. p
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not pl!�yy
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall MiTek*
design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VliTe k♦
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
MELVILLE
T21280452
76952
KJA
Diagonal Hip Girder
1
1
�ERIK
Job Reference (optional)
1 i ., rurt riarce, rL b.33U a JUI ZZ ZUZU MI I8K Industries, Inc. Fn Sep 11 14:20:53 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J4g5gF81 WFnLUszDXgBQWBDgOCOmVwuW Wy9cTE_yegne
1-11-4 3-10-7
1-11-4 1-114
Scale = 1:14.9
3x4 =
LOADING (psf)
SPACING- 2-0-0
cSl.
DEFL. in
(loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.12
Vert(LL) -0.01
3-6 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.07
Vert(CT) -0.01
3-6 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) -0.00
2 n/a file
BCDL 10.0
Code FBC2017rTP12014
Matrix -MP
Wind(LL) 0.01
3-6 >999 240
Weight: 16 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 3-10-7 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=0-7-13, 2=Mechanical, 3=Mechanical
Max Horz 1=111(LC 8)
Max Uplift 1=-64(LC 8), 2=-125(LC 8), 3=-3(LC 8)
Max Grav 1=198(LC 1), 2=146(LC 25), 3=63(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=lb)
2=125.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 60 lb down and 31 lb up at
0-0-0, and 179 lb down and 66 lb up at 3-2-11 on top chord, and 33 lb down and 6 lb up at 3-2-11 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads•(plf)
Vert: 1-2=-60, 3-4=-20
Concentrated Loads (lb)
Vert: 1=-47 8=6(B)
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall m� AyT
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IYI(IQ'k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS1/TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280453
76952
KJA5
Diagonal Hip Girder
2
1
Job Reference o tional
Chambers i russ, Inc;., ron tierce, rL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:53 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-4g5gFBIWFnLUszDXgBQWBDgxcolOwuW Wy9cTEyegne
-2-9-3 2-9-0 5-6-1
2-9-3 2-9-0 2-9-0
5-6-1
5-6-1
LOADING (psf)
SPACING-
2-0-0
cSl.
DEFL.
in
(loc)
Udefl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.41
Vert(LL)
-0.08
4-7
>865
240
TCDL 10.0
Lumber DOL
1.25
BC 0.16
Vert(CT)
-0.08
4-7
>812
180
BCLL 0.0
Rep Stress Incr
NO
WB 0.00
Horz(CT)
0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP M 30
REACTIONS. (size) 3=Mechanical, 2=0-8-2, 4=Mechanical
Max Horz 2=285(LC 8)
Max Uplift 3=-79(LC 5), 2=-369(LC 8)
Max Grav 3=134(LC 28),2=402(LC 1),4=84(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:21.5
I
N A
C
N
PLATES GRIP
MT20 244/190
Weight: 30 lb . FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-6-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=1b)
2=369.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 220 lb down and 152 lb up at
2-6-5, and 232 lb down and 78 lb up at 3-2-10 on top chord, and 36 lb down and 11 lb up at 2-6-5, and 28 lb down and 6 lb up at
3-2-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-60, 4-5=-20
Concentrated Loads (lb)
Vert: 8=47(F)10=9(F)11=6(B)
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. *��R
Design valid for use only with Mrrek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not Rq
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall Nil -
building design, Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280454
76952
L
Common
3
1
Job Reference (optional)
Chambers Truss, Inc., tort Pierce, rl- 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:54 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-YOf2TU1805TLT7okEvxlkQC3Bo?gfgmgAoM1 mQyegnd
2 6-0 7-9-10 15A-0 22-10-6 30-8-0 33-2-0
2-6-0 7-9-10 7 6 6 7-6-6 7.9-10 2-6-0
5x6 =
R nn
Scale = 1:57.8
I9
0
45 = max.. — 4x5 =
10-3-12
10-0-7
10-3-12
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Vdefi
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
-0.39 10-12
>947
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.57
Vert(CT)
-0.56 10-12
>653
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.77
Horz(CT)
0.06 8
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL)
0.16 10-12
>999
240
Weight: 180 lb FT = 20%
LUMBER -
TOP CHORD
2x6 SP No.2
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
REACTIONS.
(size) 2=0-7-10, 8=0-7-10
Max Horz 2=-393(LC 10)
Max Uplift 2=-999(LC 12), 8=-999(LC 12)
Max Grav 2=1387(LC 17). 8=1387(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-2033/1392, 4-5=-1816/1363, 5-6=-181611363, 6-8=-2033/1391
BOT CHORD 2-12=-940/1992, 10-12=-494/1296, 8-10=-1025/1721
WEBS 5-10=-456/819, 6-10=-479/532, 5-12=-457/818, 4-12=478/532
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 7-2-13 oc bracing.
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=31ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 15-4-0, Exterior(2) 15-4-0 to
18-4-13, Interior(1) 18-4-13 to 33-3-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joints) except ()t=lb)
2=999,8=999.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall�-
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280455
76952
M
Common
1
1
Job Reference o Clonal
• 1 1 • • . ,., � oaou s .tut zz zuzu INi I eK maustnes, Inc. Fn Sep 11 14:ZU:55 2U2U Page 1
I D: ml s7T W UG3iZ7eEyY9QLybykl5J-OCD QggmmnP b C5H NwocS_Ge1H rC POOmEpPS5alsyegnc
2-6-0 7-0-0 14-M 17-2-0
2 6-0 7-4-0 7-4-0 2-6-0
5x6 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
Udefl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
-0.03
6-9
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.26
Vert(CT)
-0.07
6-9
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.11
Horz(CT)
0.01
4
n/a
n/a
BCDL 10.0
Code FBC2017TrP12014
Matrix -MS
Wind(LL)
0.04
6-12
>999
240
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-7-10, 4=0-7-10
Max Horz 2=204(LC 11)
Max Uplift 2=-600(LC 12), 4=-600(LC 12)
Max Grav 2=743(LC 1), 4=743(LC 1)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-722/495, 34=722/496
BOT CHORD 2-6=-165/586, 4-6=-1651586
WEBS 3-6=0/299
Scale: 3/8"=l'
I9
0
PLATES GRIP
MT20 244/190
Weight: 79 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(l) 0-3-5 to 7-4-0, Extedor(2) 7-4-0 to
10-4-0, Interior(1) 10-4-0 to 17-3-4 zone;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb)
2=600,4=600.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall"
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
rMV2
T21280456
76952
Valley
6
1
Job Reference (optional)
unamuers truss, inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:58 2020 Page 1
ID:m I s7T W UG3iZ7eEyY9QLybykl5J-QnuZJsof3Kzmyk6VTk0hu GN sl PV Db8l F5Q KEvByegnZ
2-0-0
2-0-0
Scale = 1:7.8
3x4
LOADING (psf)
SPACING- 2-0-0
CS1.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.09
TCDL 10.0
Lumber DOL 1.25
BC 0.03
BCLL 0.0
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC20171TP12014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 1=2-0-0, 2=2-0-0, 3=2-0-0
Max Horz 1=44(LC 12)
Max Uplift 1=-23(LC 12), 2=-50(LC 12)
Max Grav 1=56(LC 17), 2=47(LC 17), 3=28(LC
3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
DEFL. in (loc) Vdefl Lid PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(CT) n/a n/a 999
Horz(CT) -0.00 2 n/a n/a
Weight: 5 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10: Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 1 and 50 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �e@
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Nat
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280457
76952
MV4
Valley
7
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
3x4
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:59 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-u_SxWCpHgd5dauhhl SXwRUVVEpolKb?PK43oRdyegnY
4-M
4-M
3x4 11
2
Scale = 1:12.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL)
n/a We 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.21
Vert(CT)
Na n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix-P
Weight: 14 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc puriins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=4-0-0, 3=4-0-0
Max Horz 1=104(LC 12)
Max Uplift 1=-55(LC 12), 3=-107(LC 12)
Max Grav 1=130(LC 17), 3=141(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 55 lb uplift at joint 1 and 107 lb uplift at
joint 3.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING-Verlfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280458
76952
MV6
Valley
5
1
Job Reference (optional)
Chambers truss, inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:00 2020 Page 1
I D: ml s1T W U G3iZ7eEyY9QLybykl5J-MAOJjYgvbxDUC2Gtb929zh S9QD9L304YZkpL_4yegnX
3x4 II
3
5 4
3x4 i 2x3 II 3x4 II
Scale = 1:18.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.31
Vert(LL) n/a n/a 999
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.12
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.14
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 23 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS.. (size) 1=6-0-0, 4=6-0-0, 5=6-0-0
Max Horz 1=168(LC 12)
Max Uplift 4=-74(LC 12). 5=-217(LC 12)
Max Grav 1=66(LC 1), 4=98(LC 17), 5=287(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-304/125
WEBS 2-5=-251/468
Structural wood sheathing directly applied or 6-0-0 oc puriins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 5-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 74 lb uplift at joint 4 and 217 lb uplift at
joint 5.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall HV
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see' ANSVTPIf Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
�Qty
T21280459
76952
MV8
Valley
4
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:00 2020 Page 1
I D:m Is?TWU G3iZ?eEyY9 QLybyklSJ-MAOJjYgvbxD U C2Gtb929zhS56 D7i3OoYZkpL_4yegnX
3x4 II
3
3x4 i 2x3 11 4 3x4 11
Scale = 1:23.3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.22
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.16
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 31 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=8-0-0, 4=8-0-0, 5=8-0-0
Max Horz 1=233(LC 12)
Max Uplift 4=-99(LC 12), 5=-299(LC 12)
Max Grav 1=96(LC 1), 4=131(LC 17), 5=396(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-358/160
WEBS 2-5=-328/528
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 7-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 99 lb uplift at joint 4 and 299 lb uplift at
joint 5.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.63681
MiTek USA, Inc. FL Cert 6634
0904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEk REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall /�+
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
k• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280460
76952
MV9
Valley
1
1
Job Reference (optional)
UlydrnOerb r fuss, inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:01 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-rMaixtrXMFLLpCg48tZOWv?EidSToTzinOYu W WyegnW
9-8-0
9-8-0
3x4 i 2x3 51 43A 11
Scale=1:27.2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) UdefI Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.32
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.16
Horz(CT) -0.00 4 n/a n/a
BCDL 10.0
Code FBC2017rTP12014
Matrix-S
Weight: 39 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=9-8-0, 44-8-0, 5=9-6-0
Max Horz 1=286(LC 12)
Max Uplift 4=-126(LC 12). 5=-355(LC 12)
Max Grav 1=129(LC 1), 4=166(LC 17), 5=471(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-373/171, 3-4=-131/259
WEBS 2-5=-369/542
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf, BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Intedor(1) 3-7-7 to 9-64 zone;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 126 lb uplift at joint 4 and 355 lb uplift at
joint S.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall my
building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/Building Component 6904 Parke East Blvd.
Safetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
T21280461
76952
MV10
Valley
�Qty
4
1
Job Reference o tlonal
-••-•••--•- • •---• •••-•• -•• • - o.�ou s �m «tutu wu i arc muusmes, Inc. rn oep i i iv:zu:ou zuzu rage i
ID:m Is?T W UG3 iZ7eEyY9QLybykl5J-U PnpuAnOXij3jRy6MJzDprlOJckw7Ciye6r7rlyeg nb
10-0-0
Scale = 1:27.5
3x4 - 5 43x4 II
2x3 11
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.70
BC 0.34
WB 0.16
Matrix-S
DEFL. in
Vert(LL) n/a
Vert(CT) n/a
Horz(CT) -0.00
(loc) I/defi L/d
n/a 999
n/a 999
4 n/a n/a
PLATES GRIP
MT20 2441190
Weight: 40 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins,
BOT CHORD 2x4 SP No.3
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=10-0-0, 4=10-0-0, 5=10-M
Max Horz 1=297(LC 12)
Max Uplift 4=-130(LC 12), 5=-368(LC 12)
Max Grav 1=134(LC 1), 4=172(LC 17), 5=488(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-381/176, 34=1351265
WEBS 2-5=-380/550
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; txp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 9-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except (jt=lb)
4=130, 5=368.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verlfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall {�� //�T�ek♦a
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chard members only. Additional temporary and permanent bracing IVi l is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS//TP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
�Qty
T21280462
76952
MV11
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Fierce, FL
3x4 i 5
2x3 11
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:56 2020 Page 1
I D:mis?TWUG3iZ?eEyY9QLybykl5J-UPnpuAnOXij3jRy6MJzDprlSwcht7CRye6r7rlyegnb
4 3x4 11
Scale=1:32.7
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.41
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.54
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.18
Horz(CT) 0.00 4 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix-S
Weight: 48 Ito FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=11-10-0, 4=11-10-0, 5=11-10-0
Max Horz 1=356(LC 12)
Max Uplift 4=-153(LC 12), 5=-444(LC 12)
Max Grav 1=162(LC 1), 4=271(LC 17), 5=626(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-426/204, 3-4=-153/292
WEBS 2-5=-446/606
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 11-84 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift atjoint(s) except (jt=lb)
4=153, 5=444.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September 11,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r ff
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MO 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
]Qly
T21280463
76952
MV12
Valley
2
1
Job Reference (optional)
cv rvn i cn a uu"'ro , uw. rn aep I I waLu:ar LULU rage 1
EyY9QLybykl5.1 bLB5Wo010rvLaXJvlUSM3gcZ?lfsfg6tmahNlyegna
ID:.[.?TWUG�,�;.
Scale = 1:33.1
3
3x4 5 8 4 3x4 11
2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.41
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.57
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.18
Horz(CT) 0.00 4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 48 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=12-0-0, 4=12-0-0, 5=12-0-0
Max Harz 1=361(LC 12)
Max Uplift 4=-155(LC 12), 5=-451(LC 12)
Max Grav 1=165(LC 1), 4=276(LC 17), 5=638(LC 17)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-430/206, 34=-155/295
WEBS 2-5=-452/611
Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 11-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)
4=155, 5=451.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912620 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
NEE,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOTs K•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/fP/f Quality Criteria, DSB-89 and BCSI Building Component
SafetyIn/ormatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280464
76952
MV14
Valley
2
1
Job Reference (optional)
t.namua.. ...... on:., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:20:58 2020 Page 1
4-0-0ID:mis7TWUG3iZ7eEyY9QLybykl5J-QnuZJsof3Kzmyk6V rk0huGNgEPUob6fF5QKEvByegnZ
1
14-0-0
Scale = 1:38.4
3x4 i 7 6 53x4 II
2x3 11 2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.23
Vert(ILL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.12
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.13
Horz(CT) 0.00 5 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 63 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD
2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD
2x4 SP M 30
except end verticals.
WEBS
2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS
2x4 SP No.3
REACTIONS.
All bearings 14-0-0.
(lb) -
Max Horz 1=426(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) except 5=-111(LC 12), 6=-248(LC 12), 7=368(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=400(LC 17), 7=477(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-468/238, 2-3=272/119
WEBS 3-6=-259/359, 2-7=362/454
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 13-10-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 111 Ib uplift at joint 5, 248 lb uplift at
joint 6 and 368 lb uplift at joint 7.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
HV
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSgrPif Quality Criteria, DSB-89 and SCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
pe
city
Ply
ERIK MELVILLE
FV-I1-SyTy
T21280465
76952
MVA
1
1
Job Reference (optional)
5.33U s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:02 2020 Page 1
I D:m Is?T W UG3iZ?eE-yY9QLybykl5J-JZ848 Ds97YTCRMPG ia4d36XUZOgcXwW rO21S2yyegnV
3x4 11
3
5 4
3x4 2x3 II 3x4 II
Scale = 1:18.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.13
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.14
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 24 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=6-3-8, 4=6-3-8, 5=6-3-8
Max Horz 1=178(LC 12)
Max Uplift 4=-78(LC 12), 5=-229(LC 12)
Max Grav 1=70(LC 1). 4=103(LC 17), 5=303(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-313/131
WEBS 2-5=-263/479
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, InteNor(1) 3-7-7 to 6-1-12 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 78 lb uplift at joint 4 and 229 lb uplift at
joint 5.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall MiTek*
design. Bracing indicated Is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing NliTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSU7P/1 Quality Criteria, DSS-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
MELVILLET21276952
�PlyTERIK
PBA
Piggyback
5
Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:03 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-nliSMZsnusb33V_SGIbsbK4iMQBTGOF_Fi17aCyegnU
22-8-0
11-4-0
Scale = 1:38.3
4x4 =
3x4 = 15 14 18 13 12 19 11 10 3x4 =
3x6 =
22-8-0
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.14
Vert(LL)
0.00
8
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.09
Vert(CT)
0.00
8
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT)
0.00
8
file
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 88 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=226(LC 11)
Max Uplift All uplift 100 lb or less atjoint(s) 2, 8 except 14=-288(LC 12), 15=-222(LC 12), 11=-288(LC 12).
10=-222(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 2, 8 except 12=392(LC 17), 14=408(LC 17), 15=296(LC 17),
11=407(LC 18),10=296(LC 18)
FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 4-5=-139/261, 5-6=-139/268
WEBS 4-14=-299/375, 3-15=-230/296, 6-11=-299/375, 7-10=-230/296
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 3-4-0 to 11-4-0, Extedor(2) 11-4-0
to 14-4-0, Interior(1) 14-4-0 to 22-4-1 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are 2x3 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
This item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8 except (it=lb)
electronically signed and
14=288, 15=222, 11=288, 10=222.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
sealed by Magid, Michael, PE
designer.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall�-
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Welk'
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/11"Pi1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
s
Truss Type
Qty
ERIK MELVILLE
JF"BB
T21280467
76952
Piggyback
1
1PIly
1
Job Reference (optional)
cuss, Inc., tort Fierce, tL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:03 2020 Page 1
ID: m Is?T W UG3iZ?eEyY9QLybykl5J-n li S MZsn usb33V_SG IbsbK4iGQBTG05_Fi 1 ?aOyegnU
11-0-0 1-8- 22-8-0
11-0-0 -8-0 11-0-0
Scale = 1:40.5
4xB =
3x4 = 15 14 16 13 12 17 11 10 3x4 =
3x6 =
LOADING (psf)
SPACING- 2-0-0
cSl.
DEFL.
in
(loc)
Vdefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.14
Vert(LL)
0.00
8
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.09
Vert(CT)
0.00
8
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT)
0.00
8
n/a
n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix-S
Weight: 88 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=-226(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 2, 8 except 14=-288(LC 12), 15=-222(LC 12), 11=-288(LC 12),
10=-222(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 2, 8 except 12=392(LC 17), 14=408(LC 17), 15=296(LC 17),
11=407(LC 18), 10=296(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 4-5=139/269. 5-6=-139/271
WEBS 4-14=-299/408, 3-15=230/296, 6-11=-299/408, 7-10=-230/296
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 3-4-0 to 11-4-0, Exterior(2) 11.4-0
to 15-4-0, Interior(1) 15.4-0 to 22-4-1 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are 2x3 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
This Item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8 except (jt=lb)
electronically signed and
14=288, 15=222, 11=288, 10=222.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
sealed by Magid, Michael, PE
designer.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II.7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall�-
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280468
76952
PBC
Piggyback
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:05 2020 Page 1
I D:mis?TWUG3iZ?eE,yY9QLybykl5J-j8gCnFu2QTrnip8rNieKg1932EtlkIfHiOW6fHyegnS
_ 10-0-0 12-8-0 22-8-0
10-0-0 2-6-0 10-0-0
Scale = 1:39.0
3x6 =
3x6 =
5 19 6 207
3x4 = 17 16 22 15 14 23 13 12 3x4 =
3x6 =
Plate Offsets (X,Y)—
[5:0-3-0,0-2-01,[7:0-3-0,0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/de0
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.12
Vert(LL)
0.00
10
n/r
120
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.10
Vert(CT)
0.00
10
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT)
0.00
10
n/a
n/a
BCDL 10.0
Code FBC20171TP12014
Matrix-S
Weight: 86 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=-199(LC 10)
Max Uplift All uplift 100 lb or less atjoint(s) 2, 14, 10 except 16=-245(LC 12), 17=-235(LC 12), 13=-245(LC 12),
12=-235(LC 12)
Max Grav All reactions 250 lb or less at joints) 2, 10 except 14=367(LC 17), 16=383(LC 17), 17=302(LC 17),
13=379(LC 18), 12=303(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 4-5=-157/275, 5.6=-141/278, 6-7=-141/278, 7-8=-157/275
WEBS 4-16=-274/395, 3-17=-236/312, 8-13=-271/395, 9-12=-237/312
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 3-4-0 to 10-0-0, Exterior(2) 10-0-0
to 16-10-15, Interior(1) 16-10-15 to 22-4-1 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise Indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
This item has been
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
electronically signed and
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 10 except
sealed by Magid, Michael, PE
Qt=lb) 16=245, 17=235, 13=245, 12=235.
using a Digital Signature.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
Printed copies of this
designer.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
0904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Not
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
7
Jab
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280469
76952
FED
Piggyback
1
3
Job Reference o floral
Chambers Truss, Inc., Fort Pierce, FL
44 =
3x4 = 12
2x3 II
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:06 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-BKNb_bvgBnzewzjt xQ9ZDyiFseD6Tm3RxgGfBjyegnR
THIS TRUSS IS DESIGNED TO SUPPORT ONLY Z-0"
OF UNIFORM LOAD AS SHOWN.
4x4 =
15 16 17 185
Scale = 1:39.3
IT
13 0
10 9 8 7
3x6 = 2x3 II 2x3 II 48 =
21-8-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.06
Vert(LL)
0.00
1
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC ' 0.03
Vert(CT)
0.00
1
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.04
Horz(CT)
0.00
7
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 251 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-5-8.
(lb) - Max Horz 2=174(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 7 except 2=-120(LC 12), 12=-309(LC 12), 8=-321(LC 12).
11=-147(LC 12). 9=-117(LC 9)
Max Grav All reactions 250 lb or less at joints) 7, 2 except 12=400(LC 17), 8=406(LC 18), 11=412(LC 17),
9=319(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 3-12=-312/424, 6-8=-314/434, 4-11=-252/282
NOTES-
1) 3-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-3-15, Interior(1) 3-3-15 to 9-0-6, Exterior(2) 9-0-6
to 13-3-5, Interior(1) 13-3-5 to 13-7-10, Exterior(2) 13-7-10 to 17-10-9, Interior(1) 17-10-9 to 21-6-4 zone;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=1b)
2=120, 12=309, 8=321, 11=147, 9=117.
9) N/A
10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
This item has been
electronically signed and.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall'
building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek'
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
MELVILLE
T21280470
76952
PBE
Piggyback
1
1
�ERIK
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:07 2020 Page 1
ID:mis?TWUG3iZ?eE-yY9QLybykl5J-fWxzBxvly56VX71EV7gomAFPm 1 YMCCJaAK?DjAyegnQ
9-0-0 13.8-0 22-8-0
9-0-0 4-8-0 9-0-0
3x6 =
19 20
Scale=1:38.8
34 =
21 22 7
3x4 = 17 16 24 15 14 25 13 12 3x4 =
3x6 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL)
0.00
10
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
Bc 0.09
Vert(CT)
0.00
10
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT)
0.00
10
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 85 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=178(LC 11)
Max Uplift All uplift 100 lb or less at joints) 2, 10 except 14=-124(LC 9), 16=-215(LC 12), 17=-240(LC 12),
13=-215(LC 12), 12=-240(LC 12)
Max Grav All reactions 250 lb or less at joints) 2, 10 except 14=380(LC 17), 16=362(LC 17), 17=307(LC 17),
13=354(LC 18),12=309(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 260 (lb) or less except when shown
WEBS 4-16=-253/361, 3-17=-241/314, 8-13=-245/361, 9-12=-243/314
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 34-0 to 9-0-0, Exterior(2) 9-0-0 to
13-2-15, Interior(1) 13-2-15 to 13-8-0, Exterior(2) 13-8-0 to 17-10-15, Interior(1) 17-10-15 to 22-4-1 zone;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.6psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
electronically Signed and
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 2, 10 except
Qt=lb) 14=124, 16=215, 17=240, 13=215,12=240.
sealed b y Magid, Michael, PE
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
using a Digital Signature.
designer.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall � at
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IYIiT®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280471
76952
PBF
Piggyback
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce. FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:08 2020 Page 1
I D:m ls7TW UG3iZ7eEyY9QLybykl5J-7iVLP HwwjO EM9HtQ3rB 1 INnaXRuOxfakO_I mGcyegnP
8-0-0 14-8-0 22-8-0
8-0-0 6-8-0 8-M
3x6 =
Scale = 1:38.8
19 6 20
3x6 =
3x4 = 17 16 15 14 13 12 3x4 =
3x6 =
22-8.0
Plate Offsets (X,Y)—
[5:0-3-0,0-2-0),[7:0-3-0,0-2-0)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Udefl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL)
0.00
10
n/r
120
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.07
Vert(CT)
0.00
10
n/r
90
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT)
0.00
10
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 84 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-0.
(lb) - Max Harz 2=158(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 2, 10 except 14=-186(LC 9), 16=-191(LC 12), 17=-242(LC 12),
13=-191(LC 12), 12=-242(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 2, 10 except 14=320(LC 21), 16=330(LC 17), 17=316(LC 17),
13=313(LC 18), 12=318(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
WEBS 6-14=-241/268, 4-16=-247/312, 3-17=-245/354, 8-13=-231/312, 9-12=-247/354
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 3-4-0 to 8-0-0, Exterior(2) 8-0-0 to
12-2-15, Interior(1) 12-2-15 to 14-8-0, Exterior(2) 14-8-0 to 18-10-15, Interior(1) 18-10-15 to 224-1 zone;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically signed and
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 2, 10 except
b Magid, Michael, PE
Qt=lb) 14=186, 16=191, 17=242, 13=191, 12=242.
sealed y g
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
using a Digital Signature.
designer.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design. into the overall Not
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280472
76952
PBG
Piggyback
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:09 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-cv3jccxYUiMCnQSccYiGrbKjzrEbg6UtdeUKo2yegnO
22.8-0
Scale=1:38.8
4x4 =
B On 119
17 ' 18
4x4 =
3x4 = 15 14 13 12 11 10 3x4 =
3x6 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defi
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
Vert(LL)
0.00
8
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.11
Vert(CT)
0.00
9
n/r
90
BCLL 0.0 '
Rep Stress Incr YES
WB 0.13
Horz(CT)
0.00
8
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix-S
Weight: 80 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purling.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=-117(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-106(LC 12), 12=-313(LC 9), 15=-176(LC 12),
10=-176(LC 12), 8=-106(LC 12). 14=-159(LC 8), 11=-164(LC 9)
Max Grav All reactions 250 lb or less at joints) 2, 15, 10, 8 except 12=483(LC 21), 14=295(LC 21), 11=295(LC
22)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 5-12=-372/428, 3-15=-180/293, 7-10=-180/293
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 34-0 to 6-0-0, Extedor(2) 6-0-0 to
10-2-15, Interior(1) 10-2-15 to 16-8-0, Extedor(2) 16-8-0 to 20-10-15, Interior(1) 20-10-15 to 22-4-1 zone;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically signed and
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 106 lb uplift at joint 2, 313 lb uplift at
12, 176lb
Sealed by Magid, Michael, PE
joint uplift at joint 15, 176lb uplift at joint 10, 106lb uplift at joint 8, 159 lb uplift at joint 14 and 164 lb uplift at joint 11.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
using a Digital Signature.
designer.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
,A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propefly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Ply
ERIK MELVILLE
T21280473
76952
PBH
Piggyback
�Qty
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:10 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-45d5gyyAEOU3OaOoAGDVNotwJFbZPZLOslEtKUyegnN
4-0-0 18-B-0 22-8-0
4-0-0 14-8-0 4-0-0
30 =
6.00 12
18
19 0 20 21
Scale = 1:38.8
3x6 =
3x4 = 17 16 15 14 13 12 3x4 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TPI2014
3x6 =
22-8-0
22-8-0
CSI. DEFL. in (loc) I/deft Ud
TC 0.09 Vert(LL) 0.00 10 n/r 120
BC 0.06 Vert(CT) 0.00 10 n/r 90
WB 0.09 Horz(CT) 0.00 10 n/a n/a
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 75 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=76(LC 11)
Max Uplift All uplift 100lb or less atjoint(s) except 2=-126(LC 12), 14=-201(LC 12), 16=-268(LC 8),
17=-148(LC 12), 13=-269(LC 9), 12=-148(LC 12), 10=-126(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 2, 10 except 14=317(LC 1), 16=327(LC 22), 17=262(LC 17),
13=327(LC 21),12=252(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 6-14=-238/260, 5-16=-245/299, 7-13=-245/299
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=2411; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-4-0, Interior(1) 3-4-0 to 4-0-0, Exterior(2) 4-0-0 to
8-2-15, Interior(1) 8-2-15 to 18-8-0, Exterior(2) 18-8-0 to 22-4-1 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically Signed and
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 126 lb uplift at joint 2, 201 lb uplift at
led Magid, Michael, PE
seay g
joint 14, 268lb uplift at joint 16, 148lb uplift at joint 17, 269lb uplift•atjoint 13, 148 lb uplift at joint 12 and 126lb uplift at joint 10.
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
using a Digital Signature.
designer.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall {{ r
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
ERIK MELVILLE
7777�'Uss
T21280474
76952
BI
Piggyback
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
6.00 12 4x4 =
3 17
2
0
c 3x4 = 16
18 4
LOADING (ps"
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TP12014
15
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:11 2020 Page 1
ID:mis?TW UG3iZ?eEyY9QLybykl5J-YHBU1 Izo?JcwOkb?kzlkwOP4JfwV80FA5yzQsxyegnM
Wi
7 21
12
CSI.
DEFL.
in
(loc)
I/defi
Lid
TC 0.14
Vert(LL)
-0.00
9
n/r
120
BC 0.08
Vert(CT)
-0.00
9
n/r
90
WB 0.11
Horz(CT)
0.00
11
n/a
n/a
Matrix-S
4x4 =
228
Scale = 1:38.8
Im
9,0 o
Io Iw
a
11 3x4 =
PLATES GRIP
MT20 244/190
Weight: 68 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 20-10-6.
(lb) - Max Horz 2=-35(LC 10)
Max Uplift All uplift 100 lb or less at joints) 2, 9 except 16=-165(LC 8), 11=-165(LC 9), 13=-192(LC 12),
15=-342(LC 8), 12=-342(LC 9)
Max Grav All reactions 250lb or less atjoint(s) 2, 9 except 16=270(LC 1), 11=270(LC 1), 13=314(LC 1).
15=405(LC 22), 12=405(LC 21)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 3-16=-195/255,8-11=-195/250,4-15=-309/370,7-12=-309/370
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf, BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 6-2-15, Interior(1) 6-2-15 to 20-8-0, Exterior(2)
20-8-0 to 22-4-1 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9 except Qt=lb)
This item has been
16=165, 11=165, 13=192, 15=342,12=342.
electronically signed and
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall r
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMPH Quality criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safelyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280475
76952
PBJ
Piggyback
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
i
6.00 12
4x5 =
4x5 =
3x4 11 2 18 3
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:12 2020 Page 1
ID:mis?T W UG3iZ?eEyY9QLybykl5J-OUlsFezRmdkneuABlgGzSDyER2EatSnJJcj_PNyegnL
30-7-2
30-7-2
17 16 15 24 14 13 12 11 10 3x4 =
3x4 11 3x6 =
Scale = 1:55.5
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CSI.
TC 0.24
BC 0.16
WB 0.16
Matrix-S
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in (loc) I/defl Ud
0.00 9 n/r 120
0.01 9 n/r 90
0.01 8 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 125 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 29-8-5.
(lb) - Max Horz 17=-306(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) 8 except 17=-106(LC 24), 14=-192(LC 12), 16=-240(LC 8),
15=-258(LC 8), 10=-342(LC 12), 13=-129(LC 12), 11=-361(LC 9)
Max Grav All reactions 250 lb or less at joint(s) 17, 14, 8 except 16=501(LC 17), 15=560(LC 18), 10=431(LC 18).
13=327(LC 22), 11=536(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 7-8=-281/131
BOT CHORD 16-17=-146/363, 15-16=-153/373, 14-15=-146/362, 13-14=-146/362, 11-13=-156/373,
10-11 =-1 561373, 8-1 0=-1 36/340
WEBS 4-14=-200/260, 2-16=299/346, 3-15=305/380, 7-10=-310/470, 6-11=415/461
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=30ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 4-7-2, Intedor(1) 4-7-2 to 7-7-2, Exterior(2) 7-7-2 to
10-7-2, Interior(1) 10-7-2 to 25-7-2, Exterior(2) 25-7-2 to 28-7-2, Interior(1) 28-7-2 to 30-3-3 zone;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
This Item has been
5) Gable requires continuous bottom chord bearing.
electronically Signed and
6) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with.any other live loads.
7) ' This has been
sealed by Magid, Michael, PE
truss designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
using a Digital Signature.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except Gt=lb)
Printed copies of this
17=106, 14=192, 16=240, 15=258, 10=342, 13=129, 11=361.
document are not considered
9) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
signed and sealed and the
desi 9
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53881
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web andfor chard members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safelylnformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280476
76952
PBK
Piggyback
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL . 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:13 2020 Page 1
I D:mis?TW UG3iZ?eEyY90Lybykl5J-UgIES_3XxseF2lNrOnC?RVP WSa9cwZTYGSXxpyegnK
0-1 10 30-7-2
0-1- 0 30-5-8
6.00 112
3x4 II
4x4 =
1 20 2 21 3
Scale = 1:54.1
19 18 17 16 15 14 13 12 11 3x4 =
3x4 11 3x6 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017frP12014
CSI. DEFL. in (loc) Udefi L/d
TC 0.16 Vert(LL) 0.00 9 n/r 120
BC 0.13 Vert(CT) 0.00 9 n/r 120
WB 0.12 Horz(CT) 0.01 9 n/a n/a
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 128 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 29-8-5.
(lb) - Max Horz 19=-307(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) except 19=-104(LC 8), 15=-200(LC 12). 18=-302(LC 8).
13=-229(LC 9), 11=-233(LC 12), 17=-177(LC 12), 16=-126(LC 12), 12=-243(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 19, 9,16 except 15=318(LC 1), 18=520(LC 17), 13=348(LC 1).
11=318(LC 18), 17=323(LC 18), 12=305(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-360/143
BOT CHORD 18-19=-141/372,17-18=-141/372,16-17=-135/363,15-16=-142/372,13-15=-142/372,
12-13=-142/372, 11-12=-132/355,9-11=-132/355
WEBS 5-15=-240/259, 2-18=-314/355, 6-13=-266/307, 8-11=-249/327, 3-17=-188/258,
7-12=-223/366
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Intedor(1) 3-1-12 to 9-0-10, Extedor(2)
9-0-10 to 11-7-2, Interior(1) 11-7-2 to 23-7-2, Exterior(2) 23-7-2 to 26-7-2, Interior(1) 26-7-2 to 30-3-3 zone;C-C for members and
farces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are 2x3 MT20 unless otherwise indicated.
This Item has been
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
electronically Signed and
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Magid, Michael, PE
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
using a Digital Signature.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 19, 200 lb uplift at
Printed copies of this
joint 15, 302 lb uplift at joint 18, 229 lb uplift at joint 13, 233 lb uplift at joint 11, 177 lb uplift at joint 17, 126 lb uplift at joint 16 and 243
document are not considered
III uplift at joint 12.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
signed and sealed and the
designer.
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall�-
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTeiC-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS9TP/1Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
City
Ply
ERIK MELVILLE
fruss
T21280477
76952
BL
Piggyback
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
30 11
4x4 =
' 20 ' 21 3
6.00 112
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:14 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-ysscfK?hl E_VtCKaP51RYel aysw7LMucnwC4TGyegnJ
Scale = 1:54.1
19 18 17 16 15 14 13 12 11 3x4 =
3x4 11 4x6 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
10.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TP12014
CSI. DEFL. in (loc) Udefl Lid
TC 0.18 Vert(LL) 0.00 9 n/r 120
BC 0.15 Vert(CT) 0.00 9 n/r 120
WB 0.12 Horz(CT) 0.01 9 n/a n/a
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 117lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pur ins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 29-8-5.
(lb) - Max Horz 19=-289(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 9,15 except 19=-11'1(LC 8), 16=-215(LC 12), 18=-320(LC 8),
13=-199(LC 12), 12=-265(LC 9), 17=-186(LC 12), 11=-249(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 19, 9 except 16=269(LC 18), 18=551(LC 17), 13=314(LC 1),
12=354(LC 1), 17=344(LC 18), 15=258(LC 1), 11=268(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-274/115
BOT CHORD 18-19=-130/354,17-18=-130/354,16-17=-124/344,15-16=-124/344,13-15=-140/356
12-13=-140/356, 11-12=-140/356, 9-11=-113/309
WEBS 4-16=-227/302, 2-18=3321375, 6-13=238/261, 7-12=-269/310, 3-17=-202/276,
8-11=-202/356
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 9-7-2, Exterior(2) 9-7-2
to 12-7-2, Interlor(1) 12-7-2 to 27-7-2, Exterior(2) 27-7-2 to 30-3-3 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
This Item has been
3) All plates are 2x3 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
electronically SI 9
signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Magid, Michael, PE
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Printed copies of this
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 15 except
document are not considered
Qt=lb) 19=111, 16=215, 18=320, 13=199, 12=265, 17=186, 11=249.
8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
signed and sealed and the
designer.
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not �®
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall ■���•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 quality Criteria, DSO.89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Jab
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280478
76952
PBM
Piggyback
1
1
Job Reference (optional)
7r
0
7-0-0
O.JJU s Jul LG LULU IVII I eK InaUstnes, Inc. rn aep 11 14:4 l:la zuzu rage l
ID:mis?TWUG3iZ?eEyY9QLybyklSJ-Q3Q tgOJ3Y6MVLvmzppg4saiDGFP4pCl?axeOiyegnl
18-7-2
Scale=1:32.9
4x4 = 2x3 II
4 15 16 5
2x3 II 3x4 II
6 17 7
3x4 = 13 12 11 10 9 8
2x3 II 2x3 II 3x6 = 2x3 II 2x3 II 3x4 II
18-7-2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Vdefi
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL)
0.00
1
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.21
Vert(CT)
0.00
1
n/r
120
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT)
-0.00
8
n/a
n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix-S
Weight: 73 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins,
BOT CHORD 2x4 SP No.3 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-8-5.
(lb) - Max Horz 2=225(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) 8, 2 except 12=-205(LC 12), 13=-237(LC 12), 10=-283(LC 9),
9=-252(LC 9)
Max Grav All reactions 250 lb or less at joint(s) 8, 2 except 12=296(LC 1), 13=316(LC 17). 10=342(LC 1),
9=310(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 2-3=-256/100
WEBS 4-12=-214/313, 3-13=-247/378, 5-10=-262/317, 6-9=-231/277
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-1-12, Interior(1) 3-1-12 to 7-0-0, Exterior(2) 7-0-0
to 11-1-12, Interior(1) 11-1-12 to 18-5-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This item has been
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2 except (jt=lb)
electronically signed and
12=205, 13=237, 10=283, 9=252.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
sealed by Magid, Michael, PE
designer•
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/f Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280479
76952
PBN
Piggyback
1
1
Job Reference o tional
a.neniuvrs r rusa, u—, run rwiuv, rr. m j ju s JUI ZZ ZUZU Mt I eK Inaustnes, Inc. t-n bep 11 1421:115 ZUZU rage 1
I D: m Is?T W UG3iZ7eE_rY9 QLybykl5J-uF_M400xgsED6VUyXW Kvd37sSga Np GevEEhBY8yegnH
13-7-2 18-7-2
13-7-2 5-0-0
Scale: 3/8'=l'
3x4 11 2x3 11
1 2
2x3 II 2x3 II 4x4 =
14 3 15 4 16 17 5
13 12 11 10 9 a 3x4 =
3x4 II 2x3 II 2x3 II 3x6 = 2x3 II 2x3 11
18-7-2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Udell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.43
Vert(LL)
0.00
6
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.29
Vert(CT)
0.01
7
n/r
120
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT)
0.00
6
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 68 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
1-5: 2x4 SP M 30 except end verticals.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-8-5.
(lb) - Max Horz 13=-161(LC 12)
Max Uplift All uplift 100 lb or less at joints) 13 except 9=-269(LC 9), 11=-273(LC 8), 12=-209(LC 8),
8=-235(LC 12), 6=-121(LC 12)
Max Grav All reactions 250 lb or less at joints) 13, 6 except 9=327(LC 1), 11=328(LC 1), 12=270(LC 1),
8=343(LC 18)
FORCES. (lb) -Max, CompJMax. Ten. -All forces 250 (Ib) or less except when shown.
WEBS 4-9=255/293, 3-11=-243/297, 5-8=-237/339
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 13-7-2, Extedor(2)
13-7-2 to 16-7-2, Interior(1) 16-7-2 to 18-3-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This item has been
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13 except (it=lb)
electronically signed and
9=269, 11=273, 12=209, 8=235, 6=121.
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
sealed by Magid, Michael, PE
designer.
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
e904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MOW
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
ERIK MELVILLE
T21280480
76952
PBO
Piggyback
1
1
Job Reference (optional)
unamoers i mss, inc., ran rierce, M
2x3 II
142
1j.33U s JUI ZZ zuzu mi I eK Inclustnes, inc. t-n Sep 11 14:21:11 2UZU Page 1
ID:mis7TWUG3iZ7eEyY9QLybykl5J-NRYIIM1 Zb9M4kf394Er89Hf663x8Yjz2TuQ14ayegnG
18-7-2
2x3 11 2x3 11
3 15 16 4 17
Scale: 3/8'=1'
4x4 = 6.00 112
5
Ia 1-,
0
13 12 11 10 9 8 3x4 =
3x4 II 2x3 II 3x6 = 2x3 II 2x3 II
2x3 11
18-7-2
18-7-2
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
Udefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.12
Vert(LL)
0.00
6
n/r
120
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.19
Vert(CT)
0.00
6
n/r
120
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT)
0.00
6
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 60 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins,
1-5: 2x4 SP M 30 except end verticals.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-8-5.
(lb) - Max Horz 13=-96(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 13 except 9=-297(LC 9), 11=259(LC 8), 12=-256(LC 8),
8=-142(LC 12), 6=-104(LC 12)
Max Grav All reactions 250lb or less atjoint(s) 13, 8, 6 except 9=347(LC 1), 11=314(LC 1), 12=317(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-9=-265/321, 3-11=-234/283, 2-12=-238/281
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 15-7-2, Exterior(2)
15-7-2 to 18-3-3 zone;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 13 except Qt=lb)
9=297, 11=259, 12=256, 8=142, 6=104.
This item has been
7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
y signed and electronically SI
g
designer.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB•89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
ERIK MELVILLE
T21280481
76952
SGEA
ROOF SPECIAL STRUCTU
1
n
L
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:20 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-nOEtwN4Su4kfb7njmMPrnvH WfHpFlt_V9rfPhvyegnD
2-6-0 0 2 4-2-12 8-10 4 10.6-0 17-0-0 23-6-0 10 29-9-0 33-3-14 3 -0 36-6-0
2 6-0 O-B- 3 6-10 4-7-8 1-7-12 6-6-0 6-6-0 1 4 4 4-11-0 3-6-10 0-8- 2-6-0
31
20
5x8 MT18HS =
6.00 12
5x10
5x10 -- 13
26-10-4
Scale = 1:70.5
V
N
C
Ia
O
„
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.55
BC 0.81
WB 0.91
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(ILL)
in (loc) Vdefl Ud
-0.15 16 >999 360
-0.31 16-17 >999 240
-0.49 10 n/a n/a
0.76 15-16 >540 240
PLATES
MT20
MT18HS
Weight: 624 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP 240OF 2.0E
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purling.
BOT CHORD 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 3-4-13 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 6-16
OTHERS 2x4 SP No.3 *Except*
44: 2x4 SP M 30
WEDGE
Left: 2x4 SP No.3, Right: 2x4 SP No.3
REACTIONS. (size) 2=0-7-10, 10=0-7-10
Max Horz 2=-440(LC 10)
Max Uplift 2=-3734(LC 12), 10=-3734(LC 12)
Max Grav 2=3156(LC 1), 10=3156(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-257/163, 2-3=-4968/12862, 3-5=-6791/17694, 5-6=-6041/15469, 6-7=-6041/15434,
7-9=-6791/17740, 9-10=-4968/12862, 10-11=-257/163
BOT CHORD 2-19=-10979/4298, 17-19=-1138214522, 16-17=-15611/6256, 15-16=-15705/6256,
12-15=-11472/4522, 10-12=-11065/4298
WEBS 6-16=-11640/4343,7-16=-852/2452,7-15=-659/477,9-15=-4393/1643,5-16=-852/2483,
5-17=-655/496, 3-17=444611643, 3-1 9=-1 398/3368, 9-12=-1398/3375
NOTES- Continued on page 2
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 Do.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
This Item has been
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
electronically signed and
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
sealed b Magid, Michael, PE
Y g
3) Unbalanced roof live loads have been considered for this design.
Using a Digital Signature.
4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=34ft; eave=4ft; Cat.
Printed copies of this
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-7-5, Interior(1) 0-7-5 to 17-0-0, Exterior(2) 17-0-0 to
document are not considered
20-4-13, Interior(1) 20.4-13 to 36-7-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
Lumber DOL=1.60
signed and sealed and the
9
shown; plate grip DOL=1.60
5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
signature must be verified
Gable End Details as applicable, or consult qualified building designer as per ANSIITPI 1.
On any electronic Copies.
6) All plates are MT20 plates unless otherwise indicated.
Michael S. Magid PE No.53681
7) All plates are 3x4 MT20 unless otherwise indicated.
MiTek USA, Inc. FL Cert 6634
8) Gable studs spaced at 2-0-0 Do.
6904 Parke East Blvd. Tampa FL 33610
9) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
Data:
10) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
September 11,2020
will fit between the bottom chord and any other members.
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke Fast Blvd.
Tampa, FL 36610
Job
Truss
Type
Qty
Ply
ERIK MELVILLET21280481
FROOF
76952
SGEA
SPECIAL STRUCTU
1
n
L
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fd Sep 11 14:21:20 2020 Page 2
ID:mis?TWUG3iZ?eEyY9QLybykl5J-nOEtwN4Su4kfb7njmMPmvHWfHpFIt V9rfPhvyegnD
NOTES-
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 2=3734, 10=3734.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-6=-140(F=-80), 6-11=-140(F=-80), 19-53=-20, 19-20=-20, 16-19=-20, 12-16=-20, 12-13=-20, 12-56=-20
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �t V
building design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing I VI iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Ply
MELVILLET21280482
�Qty
76952
SGEL
Common Structural Gable
1
1ob
[RIK
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 15:53:05 2020 Page 1
I D:mis?TWUG3iZ?eEyY9QLybykl5J-77BuhSKzHrVpwmz2Ze7ZRuh5nB7hbXyuDkdi27yegJS
-2-6-0 , 7-9-12 15-4-0 22-10-4 30-8-0 33-2-0
2-6-0 7-9-12 7-6-4 7-6-4 7-9-12 2-6-0
5x6
Anne
Scale=1:57.2
I9
0
04 —_ 18 17 16 15 14 1312 11 10
5x8 = 4x4 =
22-10-4
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/rP12014
CSI.
TC 0.43
BC 0.25
WB 0.63
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) -0.05 1946 >999 360
Vert(CT) -0.11 1946 >999 240
Horz(CT) 0.01 47 n/a n/a
Wind(LL) -0.03 1946 >999 240
PLATES GRIP
MT20 244/190
Weight: 258 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x6 SP No.2
TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing, Except:
WEBS 2x4 SP No.3
10-0-0 cc bracing: 2-19,18-19,17-18.
OTHERS 2x4 SP No.3
WEBS 1 Row at micipt 6-17, 4-17
SLIDER Right 2x4 SP No.3 -, 2-2-1
REACTIONS. All bearings 16-7-10 except Gt=length) 2=0-7-10, 18=0-3-8.
(lb) - Max Horz 2=-393(LC 10)
Max Uplift All uplift 100 Ib or less atjoint(s)12, 10 except 2=-594(LC 12), 17=-721(LC 12), 13=-296(LC 12).
8=475(LC 12)
Max Grav All reactions 250lb or less atjoint(s) 16, 15, 14. 12, 11, 10,18 except 2=696(LC 1), 17=939(LC 17),
13=379(LC 18), 8=438(LC 18), 8=413(LC 1)
FORCES. (Ib) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-625/437, 3-4=-570/453, 5-50=-102/320, 5-51=-37/266
BOT CHORD 2-19=-149/676, 18-19=-149/676, 17-18=-149/676
WEBS 5-17=-532/415, 6-17=-304/391, 6-13=-379/359, 4-17=-811/654, 4-19=0/293
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=31ft; eave=oft; Cat. II;
Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-7-4 to 0-3-5, Interior(1) 0-3-5 to 15-4-0, Exterior(2) 15-4-0 to
18-4-13, Interior(1) 18-4-13 to 33-3-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
This item has been
Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1.
electronically Signed and
4) All plates are 2x3 MT20 unless otherwise indicated.
Sealed b Magid, Michael, PE
y g
5) Gable studs spaced at 2-0-0 cc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
using a Digital Signature.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
Printed copies of this
fit between the bottom chord and any other members.
document are not Considered
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 10 except Gt=lb)
signed and sealed and the
2=594, 17=721, 13=296, 8=475, 8=475.
Signature must be Verified
LOAD CASE(S) Standard
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6634
6804 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall i�g��
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/7PI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280483
76952
V4
Valley
1
1
Job Reference (optional)
�namoers Truss, inc., Fort Fierce, Ft_ 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:26 2020 Page 1
ID:mis7TWUG3iZ7eEyY9QLybykl5J-cAb8BR8DTwVoJ2Ft6dWF1 AXeShOs9phNXn6juZyegn7
2-0-0 4-0-0
2-M 2-0-0
3x6 =
2
3x4 -
3x4
Scale = 1:7.7
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.14
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.16
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 11 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 1=4-0-0, 3=4-0-0
Max Horz 1=-28(LC 10)
Max Uplift 1=-69(LC 12), 3=-69(LC 12)
Max Gram 1=111(LC 1), 3=111(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf, h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not ��®®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall ■�Y�•
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PIf Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
MELVILLET21280484
76952
V8
Valley
1
�PlaERIK
Reference o tlonal
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:27 2020 Page 1
ID:mis?TWUG3iZ?eE,yY9QLybykl5J-4M9XOm9rEEdfxBg4gK1 UZ04ix5LTuFdXmRrGR?yegn6
4-0-0 8-0-0
4-0-0 4-0-0
3x4
20 11
44 =
3x4
Scale=1:15.1
8-0-0
LOADING (psf)
SPACING- 2-0-0
CSL
DEFL.
in (loc) Udefi Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(LL)
n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.20
Vert(CT)
n/a n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.08
Horz(CT)
0.00 3 n/a n/a
BCOL 10.0
Code FBC20171TP12014
Matrix-P
Weight: 25 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=8-0-0, 3=8-0-0, 4=8-0-0
Max Horz 1=-69(LC 10)
Max Uplift 1=-106(LC 12), 3=-106(LC 12), 4=-125(LC 12)
Max Grav 1=136(LC 1), 3=139(LC 18). 4=268(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-184/280
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 4-0-0, Exterior(2) 4-0-0 to
7-0-0, Interior(1) 7-0-0 to 7-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=106, 3=106, 4=125.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6119/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall Sat
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing IYI iTe k•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIJTP/1 Quality Criteria, DSB-69 and BCS/Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
MELVILLET21280485
�F`IyTERIK
76952
V12
Valley
�Qty
1
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:22 2020 Page 1
ID:mis?TW UG31Z?eEyY9QLybykl5J-jPLeL35iQi_MgQx6tnRJsKMor4amDynd98WloyegnB
6-0-0 12-M
6-0-0 6-0-0
Scale = 1:21.0
46 =
3x4 i 2x3 4 3x4
12-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL,
in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.82
Vert(LL)
n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.49
Vert(CT)
n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT)
0.00
3 n/a n/a
BCDL 10.0
Cade FBC20171TPI2014
Matrix-S
Weight: 39 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (size) 1=12-0-0, 3=12-0-0, 4=12-0-0
Max Horz 1=-110(LC 10)
Max Uplift 1=-141(LC 12), 3=-141(LC 12), 4=-255(LC 12)
Max Grav 1=198(LC 21), 3=204(LC 18). 4=471(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 24=-313/375
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 6-0-0, Exterior(2) 6-0-0 to
9-0-0, Interior(1) 9-0-0 to 11-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=141,3=141,4=255.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 511912020 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280486
76952
V16
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:23 2020 Page 1
ID:mis7TW UG3iZ7eEyY9QLybykl5J-BbvOYP6KB77DSaWIRUyYPYv3BU1 fyRCxrpt3lEyegnA
8-0-0
Scale = 1:27.0
4x4 =
3x4 8 7 6
3x4
20 11 2x3 11 2x3 11
16-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.40
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.06
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT) 0.00 5 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 58 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 16-0-0.
(lb)- Max Horz 1=-151(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5, 7 except 6=289(LC 12), 8=-289(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5 except 7=270(LC 1), 6=381(LC 18), 8=382(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-6=294/376, 2-8=-294/376
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 8-0-0, Exterior(2) 8-0-0 to
11-0-0, Interior(1) 11-0-0 to 15-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s)1, 5, 7 except
Qt=lb) 6=289, 8=289.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TIP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280487
76952
V20
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:24 2020 Page 1
I D:m I s7T W U G3 iZ7eEyY9QLybykl5J-fnTOml7yxJ F44k5V7CTnyISApuHh htl44Tdcghyegn 9
10-0-0 20-0-0
10-0-0 10-0-0
Scale = 1:33.5
4x4 =
3x4 - 8 7 6 3x4
2x3 II 5x6 = 2x3 II
20-0-0
20-M
Plate Offsets (X,Y)—
p:0-3-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.39
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.14
Horz(CT) 0.00
5 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix-S
Weight: 75 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-0-0.
(lb) - Max Horz 1=-192(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5 except 6=387(LC 12). 8=-387(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 6=512(LC 18), 8=512(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-6=-384/464, 2-8=-385/464
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 10-0-0, Exterior(2) 10-0-0 to
13-0-0, Interior(1) 13-0-0 to 194-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except Gt=lb)
6=387,8=387.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a buss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPH Quality Criteria, DSB-09 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job �
Tru
Truss
Truss Type
Qty
Ply
ERIK MELVILLE
T21280488
76952
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.330 s Jul 22 2020 MiTek Industries, Inc. Fri Sep 11 14:21:25 2020 Page 1
ID:mis?TWUG3iZ?eEyY9QLybykl5J-8_l mz57aidNxhughYv?OUz_Rmlg5QKhEJ7MAM7yegn8
24-0-0
12-0-0
Scale=1:40.1
4x5 =
3x4 7,� g 14 8 7 15 6 3x4
2x3 II 3x6 = 2x3 II 2x3 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lld
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.27
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.19
Vert(CT) n/a file 999
BCLL 0.0
Rep Stress Incr YES
WB 0.18
Horz(CT) 0.00 5 nla n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 89 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. Al bearings 24-0-0.
(lb) - Max Horz 1=233(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=447(LC 12), 9=-447(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=553(LC 17), 6=617(LC 18), 9=618(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=162/269, 3-4=156/269
WEBS 3-7=280/154, 4-6=-453/526, 2-9=-453/526
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 12-0-0, Exterior(2) 12-0-0 to
15-0-0, Interior(1) 15-0-0 to 23-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except
Qt=lb) 6=447, 9=447.
This item has been
electronically signed and
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53661
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component not ®®
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Sol'
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty,
Ply
ERIK MELVILLE
T21280489
76952
V28
Valley
1
1
Job Reference o Clonal
Chambers Truss, Inc., Fort Pierce, FL 8.330 s Jul 22 2020 MITek Industries, Inc. Fri Sep 11 14:21:26 2020 Page 1
I D:mis?TWUG3iZ?eEyY9QLybykl5J-cAb8BR8DTwVoJ2Ft6dWF1AXdPhl L9nxNXn6juZyegn7
14-0-0 28-0-0
14-0-0 14-0-0
Scale = 1:46.8
4x4 =
3x4 i 3x4 13 12 11 10 9 8 \
3x6 =
28-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Ydefi L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) Na n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.12
Vert(CT) n/a n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.18
Horz(CT) 0.00 7 n/a n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix-S
Weight: 116 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 28-0-0.
(lb) - Max Horz 1=-287(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 8=-369(LC 12), 9=-243(LC 12), 13=369(LC 12),
12=-243(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 7 except 10=431(LC 17), 8=491(LC 18), 9=386(LC 18),
13=491(LC 17),12=387(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-168/320, 4-5=168/320
WEBS 6-8=371/441, 5-9=-266/330, 2-13=-371/441, 3-12=-266/330
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=20ft; B=45ft; L=28ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 14-0-0, Exterior(2) 14-0-0 to
17-0-0, Interior(1) 17-0-0 to 27-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) All plates are 2x3 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
This item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 1, 7 except Qt=lb)
electronically signed and
6=369, s=za3, 13=369, 12=2a3.
sealed by Magid, Michael, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Michael S. Magid PE No.53681
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
September 11,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19l2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a buss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall�-
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS1rTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610