Loading...
HomeMy WebLinkAbout5004 Pinetree Dr FA.pdfSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-2049617 DOCUMENT #:FI1697545 AP1474740APPLICATION #: 56-PID-4756510 10/16/2020 LOT: ID#: BLOCK: SUBDIVISION:Indian River Estates APPLICANT:John R. & Gina Marie Whitaker AGENT:Alexander J. Piazza PSM, Inc John Erickson 772-260-5049 PROPERTY ADDRESS:5004 Pinetree Dr Fort Pierce, FL 34982 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. [01] TANK SIZE[][1]1090.00 [2] [02] TANK MATERIAL[]Polypropylene [03] OUTLET DEVICE[] [04] MULTI-CHAMBERED[][Y ]N/ [05] OUTLET FILTER[] [06] LEGEND[] [07] WATERTIGHT[] [08] LEVEL[] [09] DEPTH TO LID[] TANK INSTALLATION [27] SURFACE WATER[] SETBACKS FT [28] DITCHES[]47 FT [29] PRIVATE WELLS[]100 FT [30] PUBLIC WELLS[]FT [31] IRRIGATION WELLS[]FT [32] POTABLE WATER []60 FT [33] BUILDING FOUNDATIONS[]7.5 FT [34] PROPERTY LINES[]20 FT [35] OTHER[]FT [10] AREA[][1]509.4 [2] [11] DISTRIBUTION[] [12] NUMBER OF DRAINLINES[] [13] DRAINLINE SEPARATION[] [15] DEPTH OF COVER[] [16] ELEVATION [] [17] SYSTEM LOCATION[] [18] DOSING PUMPS[] [19] AGGREGATE SIZE[] DRAINFIELD INSTALLATION SQFT BOX HEADER X [ABOVE ]BMBELOW/7.00 [14] DRAINLINE SLOPE[] [20] AGGREGATE EXCESSIVE FINES[] [21] AGGREGATE DEPTH[] [36] DRAINFIELD COVER[] FILLED / MOUND SYSTEM [37] SHOULDERS[] [38] SLOPES[] [39] STABILIZATION[]09/09/2021 [40] UNOBSTRUCTED AREA[] ADDITIONAL INFORMATION [41] STORMWATER RUNOFF[] [42] ALARMS[] [43] MAINTENANCE AGREEMENT[] [44] BUILDING AREA[] [45] LOCATION CONFORMS WITH SITE PLAN[] [46] FINAL SITE GRADING[] [47] CONTRACTOR[]MICHAEL W STUHR (ASHTO [48] OTHER[]INFILTRATOR Quick4 Plus EQ36 LP [49] TANK PUMPED[] ABANDONMENT [50] TANK CRUSHED & FILLED[] [22] FILL AMOUNT[] FILL / EXCAVATION MATERIAL [23] FILL TEXTURE[] [24] EXCAVATION DEPTH[] [25] AREA REPLACED[] [26] REPLACEMENT MATERIAL[] Polylok PL-68 1.2. 1.2.5.00 70-143-11DC4 17 & 18 3 3402-602-0099-000-1 Comments are on page 2.Comments: CONSTRUCTION []:/CHD DATE: DISAPPROVED St. Lucie 05/03/2021APPROVED Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM []:/CHD DATE:DISAPPROVED St. Lucie 09/09/2021 Environmental Specialist II Nicole Montanez (Florida Department of He APPROVED (Explanation of Violations on following page) EH Database v 1.0.1 AP1474740 EID2049617 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-2049617 DOCUMENT #:FI1697545 AP1474740APPLICATION #: 56-PID-4756510 10/16/2020 Violation Number Comment The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 5x9 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Needs final inspection for mound system and final site grading. 9/9/21 Final inspection completed. Mound system checked and final site grading completed. Emailed copy to contractor and building dept. NMM Comments EH Database v 1.0.1 AP1474740 EID2049617 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC