Loading...
HomeMy WebLinkAboutENERGY EFFICINECY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Mendes Residence Builder Name: Street: 6106 Palmetto Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , 34982 Permit Number. Owner: Mendes Residence Jurisdiction: SL Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41408.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1160.00 ftz b. Frame - Wood, Adjacent R=11.0 248.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (1486.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1486.00 ft2 6. Conditioned floor area above grade (ft2) 1486 b. NIA R= ft2 Conditioned floor area below grade (W) 0 c. NIA R= ft2 7. Windows(136.0 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 75 a. U-Factor. Sgl, U=0.65 136.00 ft2 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.8 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2.882 ft. 14. Heating systems kBtu/Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor.(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1486.0 sgft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1486.00 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.092 Total Proposed Modified Loads: 43.79 PASS Total Baseline Loads: 44.00 1 hereby certify that the plans and specifications covered by Review of the plans andT�IB this calculation are in compliance with the Florida Energy specifications covered by this �o� `. ' ,_ 0�, Code, calculation indicates compliance Code. with the Florida Energy PREPARED BY: Before construction is completed , DATE: 3-29-20 I this building will be inspected for compliance with Section 653.908 0Iw' I hereby certify that this building, as designed, is in compliance Florida Statutes.' S� COD with the Florida Energy Code. E OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to o�m utdw tested in accordance with ANSURESNET/ICC 380, is not greater than 0.030 On for whole house. + td 3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Mendes Residence Bedrooms: 2 Address Type: , Street Address Building Type: User Conditioned Area: 1486 Lot # Owner Name: Mendes Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 6106 Palmetto Drive Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Detached FL, 34982 New/Existind: New (From Plans) Comment: CLIMATE Design Temp V Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1486 11888 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 232 1856 No 2 1 1 Yes Yes Yes 2 Bath 54 432 No 0 1 Yes Yes Yes 3 Bedroom 182 1456 No 1 1 1 Yes Yes Yes 4 Hall 24 192 No 0 1 No Yes Yes 5 Living Room 386 3088 No 2 1 Yes Yes Yes 6 M Bath 80 640 No 0 1 Yes Yes Yes 7 M WIC 60 480 No 0 1 No Yes Yes 8 Kitchen 234 1872 Yes 1 1 Yes Yes Yes 9 Den 156 1248 No 1 1 Yes Yes Yes 10 Laundry 78 624 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 33 ft 232 ft2 1 0 0 2Slab-On-Grade Edge Insulatio Bath 6 ft 54 ft2 -_ 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 29 ft 182 ft2 _ e 1 0 0 4 Slab -On -Grade Edge Insulatio Hall 1 ft 24 ft2 _ _ 1 0 0 5Slab-On-Grade Edge Insulatio Living Room 23 ft 386 1`12 — 1 0 0 6 Slab -On -Grade Edge Insulatio M Bath loft 80 ft2 -_ 1 0 0 78Iab-On-Grade Edge Insulatio M WIC 1 ft 60 ft2 1 0 0 3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405 2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Kitchen 13 R 234 ft2 _e 1 0 0 9 Slab -On -Grade Edge Insulatio Den 25 ft 156 ft2 1 0 0 10SIab-On-Grade Edge Insulatio Laundry 6 ft 78 ft2 - 1 0 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1661 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1486 f12 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Bedroom 0 Blown 232 ft2 0.1 Wood 2 Under Attic (Unvented) Bath 0 Blown 54 ft2 0.1 Wood 3 Under Attic (Unvented) Bedroom 0 Blown 182 ft2 0.1 Wood 4 Under Attic (Unvented) Hall 0 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) Living Room 0 Blown 386 ft2 0.1 Wood 6 Under Attic (Unvented) M Bath 0 Blown 80 ft2 0.1 Wood 7 Under Attic (Unvented) M WIC 0 Blown 60 ft2 0.1 Wood 8 Under Attic (Unvented) Kitchen 0 Blown 234 ft2 0.1 Wood 9 Under Attic (Unvented) Den 0 Blown 156 ft2 0.1 Wood 10 Under Attic (Unvented) Laundry 0 Blown 78 f12 0.1 Wood WALLS Adjacent Space Cavity Width 10 VVn11 Type1 Height Sheathing Framing Solar Below N Exterior Concrete Block - Int InsMaster Bedro 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 2 S Exterior Concrete Block - Int InsMaster Bedro 4.1 15 0 8 0 120.0 ft2 0 0 0.5 0 3 W Exterior Concrete Block - Int InsMaster Bedro 4.1 17 0 8 0 136.0 ft2 0 0 0.5 0 4 S Exterior Concrete Block - Int Insul Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 5 N Exterior Concrete Block - Int Insul Bedroom 4.1 2 0 8 0 16.0 ft2 0 0 0.5 0 6 E Exterior Concrete Block - Int Insul Bedroom 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 7 S Exterior Concrete Block - Int Insul Bedroom 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 8 E Exterior Concrete Block - Int Insttliving Room 4.1 23 0 8 0 184.0 ft2 0 0 0.5 0 9 W Exterior Concrete Block - Int Insul M Bath 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 10 W Exterior Concrete Block - Int Insul Kitchen 4.1 13 0 8 0 104.0 fie 0 0 0.5 0 11 N Exterior Concrete Block - Int Insul Den 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 12 W Exterior Concrete Block -1nt Insul Den 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Ornt F Adjacent TO Wall T Space Cavity Width Height Sheathing Framing Solar Below _ 13 N Exterior Concrete Block - Int Insul Laundry 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 14 E Garage Frame - Wood Laundry 11 13 8 104.0 ft2 0.23 0.5 0 _ 15 E Garage Frame - Wood Kitchen 11 4 8 32.0 1112 0.23 0.5 0 _ 16 N Garage Frame - Wood Living Room 11 14 8 112.0 ft2 0.23 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Living Room None .39 3 6 10 20.5 ft2 2 N Insulated Den None .39 2 10 6 10 19.4 ft2 3 E Insulated Laundry None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 1 ft 7 in 1 It 4 in None None 2 S 4 Metal Low-E Single Yes 0.65 0.25 Y 4.0 ft2 1 ft 7 in 1 ft 4 in None None 3 E 6 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 1 ft 7 in 1 ft 4 in None None 4 E 8 Metal Low-E Single Yes 0.65 0.25 Y 40.0 f12 6 ft 0 in 1 ft4 in None None 5 W 9 Metal Low E Single Yes 0.65 0.25 Y . 9.7 ft2 1 ft 7 in 1 ft 4 in None None 6 W 10 Metal Low-E Single Yes 0.65 0.25 Y 14.0 f12 1 ft7 in 1 ft 4 in None None 7 W 12 Metal Low-E Single Yes 0.65 0.25 Y 16.7 ft2 1 ft 7 in 1 ft 4 in None None 8 N 13 Metal Low-E Single Yes 0.65 0.25 Y 11.7 ft2 1 ft 7 in i It 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 374 ft2 374 ft2 31 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 1188.8 65.22 122A5 .1083 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Fkyw SHR Block Ducts 1 Central Unit/ Split Singl SEER:16 23.8 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — V — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 75 ft2 Attic 20 ft2 Prop. Leak Free Garage — cfm 44.6 afro 0.03 0.50 1 1 TEMPERATURES Programable Thermostat Y Ceiling Fans: Cooling Jan Feb Heatin Jan Feb Mar WMar Apr Apr May Jun Jul may Jun Jul AugSe Auge Oct Oct Nov Nov Dec HDec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) 78 78 78 78 78 78 78 78 78 78 PM 80 80 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM fib 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 lbs/sq.ft. ft2 ft 0.3 M Bath Default(8lbs/sq.ft. 1`12 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Den Defau 8lbs/s .ft. f12 ft 0.3 Laundry 3/29/2021 9:22 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 IM 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA . TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Mendes Residence Builder Name: Street: 6106 Palmetto Drive Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , 34982 Permit Number. `r U Owner: Mendes Residence Jurisdiction: St. Lucie County = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall'separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids bet% en fire sorink! cover glat and walls or reilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 3/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 6106 Palmetto Drive, Fort Pierce, FL, 34982 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 1160.00 ftz b. Frame - Wood, Adjacent R=11.0 248.00 ft2 1 c. N/A R= ftz 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 1486.00 ft2 1486 b. N/A R= ft2 Area c. N/A R= ftz 136.00 ft2 Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Garage a. 6 75 ft2 13. Cooling systems kBtu/hr Efficiency ftz a. Central Unit 23.8 SEER:16.00 ft2 2.882 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1486.00 fie b. N/A R= ft2 c. N/A R= ftz 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 17.0 C013:1.00 Cap: 50 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2021 9:23 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1