HomeMy WebLinkAboutENERGY EFFICINECY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Mendes Residence
Builder Name:
Street: 6106 Palmetto Drive
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL , 34982
Permit Number.
Owner: Mendes Residence
Jurisdiction: SL Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41408.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1160.00 ftz
b. Frame - Wood, Adjacent
R=11.0 248.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
11. Ceiling Types (1486.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1486.00 ft2
6. Conditioned floor area above grade (ft2) 1486
b. NIA
R= ft2
Conditioned floor area below grade (W) 0
c. NIA
R= ft2
7. Windows(136.0 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 75
a. U-Factor. Sgl, U=0.65 136.00 ft2
SHGC: SHGC=0.25
b. U-Factor: NIA ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
23.8 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 2.882 ft.
14. Heating systems
kBtu/Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Strip Heat
17.0 COP:1.00
8. Skylights Area
c. U-Factor.(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (1486.0 sgft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1486.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
16. Credits
CF, Pstat
Glass/Floor Area: 0.092 Total Proposed Modified Loads: 43.79
PASS
Total Baseline Loads: 44.00
1 hereby certify that the plans and specifications covered by
Review of the plans andT�IB
this calculation are in compliance with the Florida Energy
specifications covered by this
�o� `. ' ,_ 0�,
Code,
calculation indicates compliance
Code.
with the Florida Energy
PREPARED BY:
Before construction is completed
,
DATE: 3-29-20 I
this building will be inspected for
compliance with Section 653.908
0Iw'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.'
S�
COD
with the Florida Energy Code.
E
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to o�m utdw
tested in accordance with ANSURESNET/ICC 380, is not greater than 0.030 On for whole house. + td
3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Mendes Residence Bedrooms: 2
Address Type: ,
Street Address
Building Type: User Conditioned Area: 1486
Lot #
Owner Name: Mendes Residence Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: No
PlatBook:
Builder Name: Rotate Angle: 0
Street:
6106 Palmetto Drive
Permit Office: St. Lucie County Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County Whole House Fan: No
City, State,
Zip:
Fort Pierce,
Family Type: Detached
FL, 34982
New/Existind: New (From Plans)
Comment:
CLIMATE
Design Temp
V
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1486 11888
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 Master Bedroom 232 1856 No 2
1
1
Yes
Yes
Yes
2 Bath 54 432 No 0
1
Yes
Yes
Yes
3 Bedroom 182 1456 No 1
1
1
Yes
Yes
Yes
4 Hall 24 192 No 0
1
No
Yes
Yes
5 Living Room 386 3088 No 2
1
Yes
Yes
Yes
6 M Bath 80 640 No 0
1
Yes
Yes
Yes
7 M WIC 60 480 No 0
1
No
Yes
Yes
8 Kitchen 234 1872 Yes 1
1
Yes
Yes
Yes
9 Den 156 1248 No 1
1
Yes
Yes
Yes
10 Laundry 78 624 No 0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R Value
Area
Joist R Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio Master Bedroom 33 ft
232 ft2
1 0
0
2Slab-On-Grade Edge Insulatio Bath 6 ft
54 ft2
-_
1 0
0
3 Slab -On -Grade Edge Insulatio Bedroom 29 ft
182 ft2
_ e
1 0
0
4 Slab -On -Grade Edge Insulatio Hall 1 ft
24 ft2
_ _
1 0
0
5Slab-On-Grade Edge Insulatio Living Room 23 ft
386 1`12
—
1 0
0
6 Slab -On -Grade Edge Insulatio M Bath loft
80 ft2
-_
1 0
0
78Iab-On-Grade Edge Insulatio M WIC 1 ft
60 ft2
1 0
0
3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405 2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio Kitchen 13 R
234 ft2
_e
1
0
0
9 Slab -On -Grade Edge Insulatio Den 25 ft
156 ft2
1
0
0
10SIab-On-Grade Edge Insulatio Laundry 6 ft
78 ft2
-
1
0
0
ROOF
V
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1661 ft2
0 ft2
Light
N
0.6
No 0.9
No 20
26.57
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
1486 f12
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Master Bedroom
0
Blown
232 ft2
0.1
Wood
2
Under Attic (Unvented) Bath
0
Blown
54 ft2
0.1
Wood
3
Under Attic (Unvented) Bedroom
0
Blown
182 ft2
0.1
Wood
4
Under Attic (Unvented) Hall
0
Blown
24 ft2
0.1
Wood
5
Under Attic (Unvented) Living Room
0
Blown
386 ft2
0.1
Wood
6
Under Attic (Unvented) M Bath
0
Blown
80 ft2
0.1
Wood
7
Under Attic (Unvented) M WIC
0
Blown
60 ft2
0.1
Wood
8
Under Attic (Unvented) Kitchen
0
Blown
234 ft2
0.1
Wood
9
Under Attic (Unvented) Den
0
Blown
156 ft2
0.1
Wood
10
Under Attic (Unvented) Laundry
0
Blown
78 f12
0.1
Wood
WALLS
Adjacent Space Cavity Width
10 VVn11 Type1
Height
Sheathing Framing Solar Below
N
Exterior Concrete Block - Int InsMaster Bedro
4.1 1
0 8
0
8.0 ft2
0
0
0.5
0
2
S
Exterior Concrete Block - Int InsMaster Bedro
4.1 15
0 8
0
120.0 ft2
0
0
0.5
0
3
W
Exterior Concrete Block - Int InsMaster Bedro
4.1 17
0 8
0
136.0 ft2
0
0
0.5
0
4
S
Exterior Concrete Block - Int Insul Bath
4.1 6
0 8
0
48.0 ft2
0
0
0.5
0
5
N
Exterior Concrete Block - Int Insul Bedroom
4.1 2
0 8
0
16.0 ft2
0
0
0.5
0
6
E
Exterior Concrete Block - Int Insul Bedroom
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
7
S
Exterior Concrete Block - Int Insul Bedroom
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
_ 8
E
Exterior Concrete Block - Int Insttliving Room
4.1 23
0 8
0
184.0 ft2
0
0
0.5
0
9
W
Exterior Concrete Block - Int Insul M Bath
4.1 10
0 8
0
80.0 ft2
0
0
0.5
0
10
W
Exterior Concrete Block - Int Insul Kitchen
4.1 13
0 8
0
104.0 fie
0
0
0.5
0
11
N
Exterior Concrete Block - Int Insul Den
4.1 12
0 8
0
96.0 ft2
0
0
0.5
0
12
W
Exterior Concrete Block -1nt Insul Den
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Ornt F
Adjacent
TO Wall T
Space
Cavity Width Height
Sheathing Framing Solar Below
_ 13 N
Exterior Concrete Block - Int Insul Laundry
4.1 6 0 8
0 48.0 ft2
0
0 0.5
0
14 E
Garage Frame - Wood
Laundry
11 13 8
104.0 ft2
0.23 0.5
0
_ 15 E
Garage Frame - Wood
Kitchen
11 4 8
32.0 1112
0.23 0.5
0
_ 16 N
Garage Frame - Wood
Living Room 11 14 8
112.0 ft2
0.23 0.5
0
DOORS
#
Omt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E Insulated
Living Room
None
.39 3
6 10
20.5 ft2
2
N Insulated
Den
None
.39 2
10
6 10
19.4 ft2
3
E Insulated
Laundry
None
.39 2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID Frame Panes
NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
S 2 Metal Low-E Single
Yes
0.65 0.25 Y
20.0 ft2 1 ft 7 in
1 It 4 in
None
None
2
S 4 Metal Low-E Single
Yes
0.65 0.25 Y
4.0 ft2 1 ft 7 in
1 ft 4 in
None
None
3
E 6 Metal Low-E Single
Yes
0.65 0.25 Y
20.0 ft2 1 ft 7 in
1 ft 4 in
None
None
4
E 8 Metal Low-E Single
Yes
0.65 0.25 Y
40.0 f12 6 ft 0 in
1 ft4 in
None
None
5
W 9 Metal Low E Single
Yes
0.65 0.25 Y .
9.7 ft2 1 ft 7 in
1 ft 4 in
None
None
6
W 10 Metal Low-E Single
Yes
0.65 0.25 Y
14.0 f12 1 ft7 in
1 ft 4 in
None
None
7
W 12 Metal Low-E Single
Yes
0.65 0.25 Y
16.7 ft2 1 ft 7 in
1 ft 4 in
None
None
8
N 13 Metal Low-E Single
Yes
0.65 0.25 Y
11.7 ft2 1 ft 7 in
i It 4 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
374 ft2 374 ft2
31 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000305 1188.8 65.22 122A5 .1083
6
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA
17 kBtu/hr
1
sys#1
3/29/2021 9:22 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Fkyw
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER:16 23.8 kBtu/hr cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
V
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 75 ft2
Attic
20 ft2 Prop. Leak Free
Garage
— cfm
44.6 afro 0.03
0.50
1 1
TEMPERATURES
Programable Thermostat Y
Ceiling Fans:
Cooling Jan Feb
Heatin Jan Feb
Mar
WMar
Apr
Apr
May Jun Jul
may Jun Jul
AugSe
Auge
Oct
Oct
Nov
Nov
Dec
HDec
Venting Jan Feb
Mar
Apr
May Jun Jul
Aug
Sep
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
78
78 78 78
78
78
78
78
78
78
PM
80
80
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating(WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
fib
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 lbs/sq.ft.
ft2
ft
0.3
M Bath
Default(8lbs/sq.ft.
1`12
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Den
Defau 8lbs/s .ft.
f12
ft
0.3
Laundry
3/29/2021 9:22 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
IM
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
. TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Mendes Residence Builder Name:
Street: 6106 Palmetto Drive Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL , 34982 Permit Number.
`r
U
Owner: Mendes Residence Jurisdiction: St. Lucie County
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall'separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
bet% en fire sorink! cover glat and walls or reilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
3/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.25
b. U-Factor: N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
6106 Palmetto Drive, Fort Pierce, FL, 34982
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1160.00 ftz
b. Frame - Wood, Adjacent
R=11.0
248.00 ft2
1
c. N/A
R=
ftz
2
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
No
a. Roof Deck (Unvented)
R=20.0
1486.00 ft2
1486
b. N/A
R=
ft2
Area
c. N/A
R=
ftz
136.00 ft2
Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: Garage
a.
6 75
ft2
13. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
23.8 SEER:16.00
ft2
2.882 ft.
0.250
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1486.00 fie
b. N/A R= ft2
c. N/A R= ftz
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
17.0 C013:1.00
Cap: 50 gallons
EF: 0.95
CF, Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/29/2021 9:23 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1