Loading...
HomeMy WebLinkAboutOSTDS NEWSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL RECENED SYSTEM CONSTRUCTION PERMIT FOR: APPLICANT: Elvira Mendes OSTDS New PROPERTY ADDRESS: 6100 Palmetto Dr Fort Pierce, FL 34982 MAY'.2 6 2021 PERMIT #:56-SF-2249516 APPLICATIoN #: AP1636730 Permittieg Department St. Lucie covw LOT: 40 & 41 BLOCK: 12 SUBDIVISION: Indian River Estates PROPERTY ID #: 3402-607-0066-000-6 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1563014 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 500 ] SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [x] FILLED [ ] MOUND I CONFIGURATION: [ ] TRENCH [x] BED [ ] N F LOCATION OF BENCHMARK: Site BM, NiD E side of Rd @ driveway I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D E O T H E R [ 12.00 ] [ INCHES FT ] [ABOVE BELOW ]BENCHMARK/REFERENCE POINT [ 11.00 ] I INCHES FT ] [ABOVE BELOW ] BENCHMARK/REFERENCE POINT REQUIRED: LI/.UU] INCHES EXCAVATION REQUIRED: [ 00-UU] INCHES system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of gpd. SPECIFICATIONS BY �4 Brian J,,Tngram TITLE: Environmental Specialist III APPROVED BY: TITLE: Environmental Specialist III St. Lucie CHD Brian Ingram DATE ISSUED: 05/07/ 21 EXPIRATION DATE: 11/07/2022 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1636730 SE1520036 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: #: 56-SF-2249516 BILL HOC #:56-BID-5197078 CONSTRUCTION APPLICATION #: AP1636730 RECEIVED FROM: Culpepper & Terpening AMOUNT PAID: $ 545.00 PAYMENT FORM: CHECK 1024 PAYMENT DATE: 03/10/2021 MAIL TO: Elvira Mendes FACILITY NAME: PROPERTY LOCATION: 6100 Palmetto Dr Fort Pierce, FL 34982 Lot: 40 & 41 Block: 12 Property ID: 3402-607-0066-000-6 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - Surcharge (All) 1 $ 45.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123 - OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 RECEIVED BY: AdamsC AUDIT CONTROL NO. 56-PID-4901599 STATE OF FLORIDA PERMIT NO. DEPARTMENT OF HEALTH DATE PAID: Q� ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: '. SYSTEM RECEIPT #: `°°"E -APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: [X] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Elvira Mendes AGENT: Culpper & Terpening, Inc. TELEPHONE: 772-464-3537 MAILING ADDRESS: 2980 South 25th Street, Ft. Pierce, FL 34981 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION A portion of lots 40 and 41 (SEE PLOT PLAN FOR LEGAL DESCRITION) LOT: BLOCK: 12 SUBDIVISION: Indian River Estates Unit 6 PLATTED: 1956 PROPERTY ID #: 3402-607-0066-000-6 ZONING• RS-3 I/M OR EQUIVALENT: [ Y CD PROPERTY SIZE: 0.3 58 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [X ]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y /(2D3 DISTANCE TO SEWER: None FT PROPERTY ADDRESS: 6100 Palmetto Drive, Ft. Pierce, FL 34982 DIRECTIONS TO PROPERTY: East on Easv Street to Palmetto Drive. North on to the 3rd house on the left. BUILDING INFORMATION [X] RESIDENTIAL [ ] COMMERCIAL Unit Type of No Establishment No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 1 Single Family Res. 2 1486 2 3 4 [ 0 ] Floor/Equipment Drains [ ], ' Othei : (Speai.fy) SIGNATURE: DATE. Z° DH 4015, 08/09 (Obsoletes previous I%editionp *hitch may not be used) Incorporated 64E-6.001, FAC Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Elvira Mendes CONTRACTOR / AGENT: Culpepper & Terpening LOT: 40 & 41 BLOCK: 12 SUBDIVISION: Indian River Estates ID#: 3402-607-0066-000-6 APPLICATION # AP1636730 PERMIT # 56-SF-2249516 DOCUMENT # SE1520036 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.36 ACRES TOTAL ESTIMATED SEWAGE FLOW: 300 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 900.02 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 750.00 SQFT UNOBSTRUCTED AREA REQUIRED: 750.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site BM. NiD E side of Rd ELEVATION OF PROPOSED SYSTEM SITE 12.00 [I INCHES I/ FT ] [I ABOVE I/ BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 15 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 75 FT NON -POTABLE: 50 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 65 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE i cnTT. vunrTT.r TWrn10hMrPTnW crmc- 7 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 4/1 Sand 0 To 7' 1 OYR 5/1 Sand 7 To 30 10YR 6/1 Sand 25 To 33 10YR 2/1 Spodic Material 33 To 42 10YR 5/2 Sand 42 To 46 1OYR 2/1 Spodic Material 46 To 58 1OYR 4/4 Fine Sand 58 To 62 10YR 5/3 Fine Sand 62 To 72 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 4/2 Fine Sand 0 TO 8 10YR 5/2 Fine Sand 8 To 35 10YR 6/1 Fine Sand 26 To 38 10YR 2/1 Spodic Material 38 To 50 10YR 3/4 Fine Sand 50 To 59 10YR 4/3 Fine Sand 59 To 66 10YR 5/3 Fine Sand 66 To 72 OBSERVED WATER TABLE: 60.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 25 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 25.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [ ] TRENCH [X ] BED REMARKS/ADDITIONAL CRITERIA Sand/0.60 DEPTH OF EXCAVATION: [ ] OTHER (SPECIFY) WSWT determined suing USDA WSS and soil borings. 10YR6/1 stripping In 10YR5/1 matrix >10% with diffuse boundaries starting at 25" in S61. S131 12" above BM. S132 10" above BM. SITE EVALUATED BY: Ingram, Brian (Tit/ : Environmental Specialist III) (ENVIRONMENTAL HEALTH) ditions DH 4015, 08/09 (Obsoletes previous ewh' h may not be used) Incorporated: 64E-6.001, FAC AP1636730 EID2249516 58 INCHES DATE: 05/03/2021 Page 3 of 4 v 1.0.2 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: PALMETTO Parcel ID: 3402-607-0066- Account #: 189488 Sec/Town/Range: 11/36S/40E DR 000-6 Map ID: 34/1IS Zoning: RS-3 - Cou Use Type: 0100 Jurisdiction: Saint Lucie County Ownership Elvira Mendes 6101 Palmetto DR Fort Pierce, FL 34982 Current Values Just/Market: Assessed: Exemptions: Taxable: Date Book/Page Legal Description INDIAN RIVER ESTATES -UNIT 06-BLK 12 THAT PART OF LOTS 40 AND 41 MPDAF: FROM SE COR OF LOT 41, TH N 89 38 13 W 219.47 FT TO POB; TH CONT N 89 38 13 W 80 FT TO W LI OF LOT 41, TH N 00 2126 E 132.04 FT TO N LI OF LOT 40, TH S 89 38 13 E 298.40 FT TO W RD R/W LI OF PALMETTO DR, TH S 00 06 20 W 30 FT, TH N 89 38 13 W 30 FT, TH N 00 06 20 W 8 FT, TH N 89 38 13 W 188.58 FT, TH S 00 21 26 W 110.04 FT TO POB (0.358 AC) Historical Values 3-year Year Just/Market Assessed Exemptions Taxable Sale History Sale Code Deed Grantor Total Areas Finished/Under Air 0 (SF): Gross Sketched Area 0 (SF): Land Size (acres): 0.36 Land Size (SF): 15,662 Total Building Count: Special Features and Yard Items Type Qty Units Year BIt UTILITY AVG 1 280 1999 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2021 Saint Lucie County Property Appraiser. All rights reserved. Price qt wf `4�,q�Oli � �rN�,�K�.C• r e :s f6' •c '1",,��R�q,- }�}�' , .r � �R ��.&y. � {oFi :���1 ,�M3'�7r r.R„ ..x. � '� ,r .. � �i a ¢•C m '•f Ya 1 ��'�fifi� a a. �.� r� ,..r� a v.F,• _ - C ILI, �5 � .. , *� - {� � � Wit,✓. S.a� ��_ la 41 All 71 "� "Jsl� '� H' FwL' - _ ' L = •�- � - � .. Y pCq� - 1000 . `gyp.. ' -� t� 1• ,' F7 Y _ LZ r y 3 �` r .f _ - �•�' ;may r _ _ _ _ t C - - '1'. -# I - . h'+qI J r h 1 r •�.a x lr�xi'� t tx• r I R" � q C..� n d Y" 8' ,y,, C"`b'' '�� r 73,`� tty = -.. 1 .I - �_ - F -- ar...arim -_ 4--�,iS' ;f, I ��••£ u, �}. ��L ; � - �- �' y k.r= 3P. y 7'-�v r .��:�� w�. r � _ it -� „a _ -y�.' r _s� • 4��'� ^'. C,,, Custom Soil Resource Report St. Lucie County, Florida 21—Lawnwood and Myakka sands Map Unit Setting National map unit symbol: 1 jpvg Elevation: 0 to 200 feet Mean annual precipitation: 49 to 58 inches Mean annual air temperature: 70 to 77 degrees F Frost -free period. 350 to 365 days Farmland classification: Farmland of unique importance Map Unit Composition Lawnwood and similar soils: 41 percent Myakka and similar soils: 39 percent Minor components: 20 percent Estimates are based on observations, descriptions, and transects of the mapunit. Description of Lawnwood Setting Landform: Marine terraces on flatwoods Landform position (three-dimensional): Talf Down -slope shape: Linear Across -slope shape: Linear Parent material: Sandy marine deposits ' Typical profile A - 0 to 8 inches: sand E - 8 to 28 inches: sand Bh1 - 28 to 52 inches: sand Bh2 - 52 to 58 inches: sand C - 58 to 80 inches: sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: 10 to 31 inches to ortstein Drainage class: Poorly drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately low to moderately high (0.06 to 0.20 in/hr) Depth to water table: About 6 to 18 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum: 4.0 Available water capacity. Very low (about 0.9 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4w Hydrologic Soil Group: A/D Forage suitability group: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) 10 Custom Soil Resource Report Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) Hydric soil rating: No Description of Myakka Setting Landform: Flatwoods on marine terraces Landform position (three-dimensional): Talf Down -slope shape: Convex Across -slope shape: Linear Parent material: Sandy marine deposits Typical profile A - 0 to 7 inches: sand E - 7 to 27 inches: sand Bh - 27 to 38 inches: sand C - 38 to 80 inches: sand Properties and qualities Slope: 0 to 2 percent Depth to restrictive feature: More than 80 inches Drainage class: Poorly drained Runoff class: High Capacity of the most limiting layer to transmit water (Ksat): Moderately high to high (0.57 to 5.95 in/hr) Depth to water table: About 6 to 18 inches Frequency of flooding: None Frequency of ponding: None Maximum salinity. Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm) Sodium adsorption ratio, maximum: 4.0 Available water capacity. Low (about 4.5 inches) Interpretive groups Land capability classification (irrigated): None specified Land capability classification (nonirrigated): 4w Hydrologic Soil Group: A/D Forage suitability group: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) H, ydric soil rating: No Minor Components Ankona Percent of map unit., 7 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Talf Down -slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) Hydric soil rating: No Electra Percent of map unit. 7 percent 11 Custom Soil Resource Report Landform: Knolls on marine terraces, rises on marine terraces Landform position (three-dimensional): Interfluve Down -slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on rises and knolls of mesic uplands (G156BC131 FL) Hydric soil rating: No Waveland Percent of map unit: 6 percent Landform: Flatwoods on marine terraces Landform position (three-dimensional): Talf Down -slope shape: Convex Across -slope shape: Linear Other vegetative classification: Sandy soils on flats of mesic or hydric lowlands (G156BC141 FL) Hydric soil rating: No 12 FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes. AllPrevious Site Plans for OSTOS # f-22 &Well # Date: 7 a r R TABULATION AREA LIVING AREA 1486 SF FRONT ENTRY 145 SF GARAGE 327 SF AIR CONDITIONED SPACE TOTAL 1958 SF VOLUME 12440CF PROTECTION OF OPENINGS:. RASED ON FSC SECTION 1606.1.4 N EXTERIOR OPENING THAT RECEIVES POSITIVE PRESSURE SHALL SE PROTECTE➢ WITH AN IMPACT RESISTANT COV E R IN G MATERIAL THAT MEETS THE REQUIREMENT OF SST➢12 ��/��•� ASTME1886 AND ASTME1996 OR MIAMI-➢ADE PA201,202 L 203 NOTE. BLOCK LAYERS / FRAMERS TO CONSULT W/CONTRACTOR FOR ROUGH OPENINGS OF WINDOWS AND DOORS DOOR SCHEDULE SIZE ROUGH OP QUANTITY REMARKS 3'0'X6'8'Xl 3/4' 38'x8l' I EXTERIOR DR r 2'8"X6'8"X1 3/8" 34x81' INT RIOR DR2'6"X6'8"Xl 3/8" 32'x8l' 2 POCKET DR. 2'e"X6'B"Xl 3/8" 34'x81' 1 GA Dr. 1 HR FIRE -RATED '8"X6'8"X / " 36'x8l' 1 WINDOW SCHEDULE FIRE SAFETY OPENING EGRESS WINDOWS IN SLEEPING ROOM MUST HAVE A MINIMUM CLEAR OPENINC HEIGHT OF 24' & A MIN NET CLEAR WIDTH OF 20'. NET CLEAR OPENING AREA SHALL BE A MIN OF 5 S0. FT. ON GROUND FLOOR 5.7 SQ. FT. ABOVE GROUND LEVEL , MAX SILL HEIGHT 44 ABOVE FFE SCALE 1/4"=1'0" DATE:1-18-2021 HORIZ. �SCALE .Y"=20' -: VERT. CALE N`A Joe No. 20-098 SHEET... 1 : OF.. 1 z c� I,