HomeMy WebLinkAboutAPPROVED 01) 1st floor plan - EsignedGYPSUM ecAfRD: R102,3 R102,3,1 Materials, All gypsum board materials and accessories shall conform to ASTM C 36, C 113, C 415, C 514, G 630, C 931, C 960, G 1002, C 1041, C 1111, C 1118, C 1218, C 1395, C 139f0 or G 1658 and shall be installed in accordance with the provisions of this section, Adhesives for the installation of gypsum board shall conform to ASTM C 551, R102,3,2 Wood framing, Wood framing supporting gypsum board shall not be less than 2 inches (51 mm) nominal thickness in the least dimension except that wood furring strips not less than I-inch-by-2 inch (25 mm by 51 mm) nominal dimension may be used over solid backing or framing spaced not more than 24 inches (610 mm) on center, R102,3.3 Cold -formed steel framing. Cold -formed steel framing supporting gypsum board shall not be less than 11/4 inches (32 mm) wide in the least dimension, Nonload-bearing cold -formed steel framing shall comply with ASTM C 645, Load -bearing cold -formed steel framing and all cold -formed steel framing from 0.033 inch to 0.112 inch (I mm to 3 mm) thick shall comply with ASTM C 955, R102,3,4 Insulating concrete form walls. Foam plastics for insulating concrete form walls constructed in accordance with Sections R404,1,2 and R611 on the interior of habitable spaces shall be protected in accordance with Section R316,4, Use of adhesives in conjunction with mechanical Fasteners is permitted. Adhesives used for interior and exterior finishes shall be compatible with the insulating form materials, R102,3,5 Application, Maximum spacing of supports and the size and spacing of Fasteners used to attach gypsum board shall comply with Table R102.3.5. Gypsum sheathing shall be attached to exterior walls In accordance with the standards used for the design of the building as specified in Section R301,2,1.1, Gypsum board shall be applied at right angles or parallel to framing members, All edges and ends of gypsum board shall occur on the framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to the weather or to water, CERAMIC: TILE INSTALLATION: R102.4 Ceramic tile. R102.4,1 General, Ceramic the surfaces shall be installed in accordance with ANSI A105A A108,4, A108,5, A108.6, A106.11, A118,1, A1183, A136,1 and A131,1, R102.4.2 Fiber -cement, fiber -mat reinforced cement, glass mat gypsum backers and fiber -reinforced gypsum backers. Fiber -cement, fiber -mat reinforced cement, glass mat gypsum backers or fiber -reinforced gypsum backers in compliance with ASTM C 1288, G 1325, C 1118 or C 1215, respectively, and installed in accordance with manufacturers' recommendations shall be used as backers for wall the in tub and shower areas and wall panels in shower areas. BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS 8 SKYLIGHTS: PRODUCT MODEL # MANUFACTURER ATTACHMENT METHOD TYPE, SIZE, SPACING d EMBEDMENT BUILDING DESIGN PRESSURE EXPIR. DATE APPROVAL EVALUATION AGENCY PRODUCT DESIGN PRESSURE WINDOWS (FIXED GLASS) "SENTINEL 130" (L,M,I, ALUM,) CGI 1/4" x 2 3/4" TAPCONS / "12 HEAD -11,0 +80.0 / -80,0 09/22/2025 20-0519,09 MIAMI / DADE FRENCH DOOR (GLAZED W/ WO S,LITE) "SENTINEL 160" (L.M,I, ALUM,) CGI 1/4" x 2 3/4" TAPCONS / 12 HEAD +53,0 / -11,0 +80.0 / -80,0 05/00/2023 20-0122,16 MIAMI / DADE FRENCH DOOR (ALUMIN,) SERIES 150 (IMPACT) PGT 1/4" x 2 3/4" TAPCONS /12 HEAD +53,0 / -11,0 +100,0 / -100,0 02/24/2025 20-0421.03 MIAMI / DADE SLIDING GLASS DOOR (ALUM,) SGD-110 (IMPACT) PGT 1/4" x 2 3/4" TAPCONS / 012 HEAD +53,0 / -11,0 +90,0 / -90,0 02/1-1/2025 20-0429,09 MIAMI / DADE MULLION BAR (ALUM,) "SENTINEL" L.M.I. (UNCLIPPED) CGI 1/4" x 2 3/4" TAPCONS / #12 NERD +53,0 / -11,0 +90,0 / -90.0 013/22/2025 20-0406,05 MIAMI / DADE MULLION BAR (ALUM, TUBE) HEAVY DUTY L.M.I. (IMPACT) CGI 1/4" x 2 3/4" TAPCONS / 012 HEAD +53,0 / -11,0 +I10,0 / -110,0 05/26/202ro 20-0406,08 MIAMI /DADE GARAGE DOOR STL, DR, (UP TO 16'2") HURR. MAST, 811/824 DAB DOOR 1/4" x 2 3/4" TAPGONS / #12 HEAD SEE MANUF, SPECS, +46.5 / -51.6 +56,0 / -64,0 02/22/2025 20-0929,12 MIAMI /DADE PRODUCT MODEL # MANUFACTURER ATTACHMENT METHOD TYPE, SIZE, SPACING 4 EMBEDMENT BUILDING DESIGN PRESSURE EXPIR. DATE APPROVAL EVALUATION AGENCY PRODUCT DESIGN PRESSURE ROOFING (STANDING SEAM METAL) DMG 1508E (24 GA,) DREXAL METALS PER MANUF, +35,9 / -119,1 -121,15 N/A FL-11618,1 R1 FL. NUMBER UNDERLAYMENT (SELF ADHERED) METSHIELD DREXAL METALS SELF ADHERED PEEL AND STICK, PER MANUF, SPECS. +35.9 / -119,1 N/A N/A FL-16342 R3 FL, NUMBER STUCCO NA NA STUCCO ON MTL, LATH +25,4 / -40,4 NA NA MIAMI / DADE BUILDING DATA 4 DESIGN PRESSURE SCHEDULE PROJECT/NAME KABLER RESIDENCE ARCHITECT M.A. CORSON 4 ADDRESS: ASSOCIATES, INC, ALL PRESSURES CALCULATED WITH THE FOLLOWING: I, WIND LOADS BASED ON F.B.C. 2020 (ITI-I ED.) 8, WALL ZONE (PSF): 4) SEE ENGIN PLANS 8 ASCE 1-liv, AND N.E.C. 2020 5) 2, BUILDING DESIGNED AS: ENCLOSED OPEN S, GARAGE DOOR (PSF): 3, MEAN BUILDING HEIGHT: 24 FT, ROOF PITCH: 6 /12 10, LOADS: FLOOR (00 PSF INTERNAL PRESSURE COEFICIENT +/- 0,18 ROOF/DEAD 15 PSF ROOF LIVE 30 PSF 4, WIDTH OF END ZONE: 4' 11, SHEAR WALLS CONSIDERED FOR STRUCTURE? WIND SPEED: ALT. 110 MPH 3 SECOND GUST - YES X NO NOMINAL: 132 MPH 12. CONTINUOUS LOAD PATH PROVIDED? 5. BUILDING CLASSIFICATION TABLE 1-1. ASCE 1 YES X NO F.B.C. TABLE 1604,5 13, ARE COMPONENT d CLADDING DETAILS PROVIDED? 6, EXPOSURE CATEGORY: D ADJUSTMENT FACTOR: 1,10 YES X NO 1, COMPONENTS d CLADDING WIND PRESSURE ON: 14, SOIL SEARING CAPACITY: 2500 PSF ROOF ZONE (PSF): U SEE ENGIN PLANS PRESUMPTIVE: BY TEST: X 2) 3) 15. TYPE CONSTRUCTION (TABLE 601) N/A (R302,I) *ALL ZONES CALCULATED FOR WORST CASE SCENARIO, (10 S,F, EFFECTIVE WIND AREA) GENERAL NOTES: 1, VERIFY LOCATION OF UTILITIES W/ SUBDIVISION BEFORE PROCEEDING WITH WORK, 2, CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS OR EASEMENTS ARE ENCROACHED, (OWNER, 8 OR CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS, EASEMENTS, LOT COVERAGES, ETC,) 3. PROVIDE ACCESS TO ALL CONCEALED PLUMBING SLIP JOINTS, 4, PROVIDE EGRESS WINDOW UNIT AT BEDROOMS, 5, DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS, 6, PROVIDE PVC SLEEVES AS REQUIRED AT DRIVEWAY AND SIDEWALKS FOR LANDSCAPE LIGHTING AND IRRIGATION. 1, VERIFY A/C UNITS SEER WITH ENERGY CODE. 8. USE TEMPERED GLASS AT ALL HAZARDOUS AREAS. 9, USE MOISTURE RESISTANT DRYWALL AT WET AREAS, 10. SURVEYOR SHALL VERIFY ALL SITE DIMENSIONS, EASEMENTS B SETBACKS PRIOR TO ANY CONSTRUCTION AND SHALL IMMEDIATELY CONTACT 4 NOTIFY ARCHITECT IF ERRORS OR PROBLEMS ARISE, II. OWNER 4 OR CONTRACTOR IS RESPONSIBLE FOR PROVIDING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD. Digitally signed Mark by Mark Corson W Date: 2021.09.10 Corson 12:19:32-04'00' AREA CALCULATIONS IST FLOOR A/C 190 S.F. 2ND FLOOR A/C 1515 S.F. 3RD FLOOR A/C 1314 S.F. TOTAL A/C 31313 S.F. GARAGE 106 S.F. ENTRY 13 S.F. COV, PORCH 213 S.F. REAR BALCONY 155 BY, REAR TERRACE 305 S.F. FRONT BALCONY 130 S.F. FRONT TERRACES 64 S.F, 15T FL, STOR, 841 BY, TOTAL NON -A/C 2520 BY, TOTAL UNDER ROOF 5659 S.F. * Contractors to verify all footages * All areas are calculated to Outside dimensions. PROPERTY LINE L = 1210' P - 1 20' 8" 14' 0'1 24' 4" 11' 10" II01 „ 1' 4" 51 011 11411 1' 1" 5' S11 GONG, PAVER ALK 6 2' CONC. A 3 O 01 I I � I I m CONC. PAVER PATIO -0'1" F N. FL. 8.42 .A.V.D. I _ I � I r I Q' I _ \' 1( . S I '` C R 04 O co I N TILE FL I I r I I I � i I I -0'5 1/211 FIN. FL. I I 8.54 .A.V.D. I /8" STUCCO ON " x 24" GONG. I BILK, COL . m 21011 1 10,0" 1 1 411 1 51 O11 1 1 411 O'O" FIN. FL. V. X p x 5' 4" F C,. 2'2"x2'211 Ip 2'211x5'311 F,G, F LOUV. ALUMIN `GATES u U / - Q U 114'0"� _z -I'O11 FIN. FL. A/C COND, ON STANDS (TYP.) HYDROSTATIC VENTS 4"-12" AFF - TYP. 5 PLACES NOTE: ALL INTERIOR FRAME WALLS TO BE DESIGNED AS BREAKAWY WALLS STORAGE S'411 CLG, HT. TILE FL. (NON -HABITABLE SPACE) 8' 6" J HYDROSTATIC OPENINGS - / "SMART VENTS" OR EQ, (5) 1611 x 16" FLOOD VENTS MODEL «: 1540-521 AT FLOOR LEVEL (1131 S.F. REQUIRED VENTED - 2000 t-A S.F. PROVIDED) 31' 8 22' 4" n m N m S oTO 5' 611 2' 8" 4'0"x5'O" F.G. O'O" FIN. FL. 9.0 N.A.V.D. II' 611 6 1' 2" s 41411 FOCI E 9'4" CL'G, HT. TILE (NON -HABITABLE B \SPACE) (5) 6.811 O'O" FIN. FL. STEPS l 3,5'1x3,511 I/411 O P ti STL. COL `tom (4 PLACE S O UP 7 --------- - -' k0 �., �0 3 2 --------- J = - - - - - - - - - - I - 1 410" FIN. FL. - -----"--=---7 6.1 N.A.v.D. - - - -�, OIIOII- - - - ■ O ro ACCESS TANKLESS DOOR - W.H. (ELECT.) R Y SIZE PAVER WALK 5/5" STUCCO ON -0'3/4" FIN. FL. 1211x1211 CONC. BLK. COL. O -0'211 FIN. FL. -2'2" FIN. FL, O 10' 10118.84 N.A,V.D. ' 011 1' 01 1' x Q _L O I ENTRSLOPE WALK DN. 2� 2' 2" 4'0"x8'O" FR. DR 11 1/2" MAX. THRE HT, PER FBC R311,3,1 5 EQ. RISERS ,w 6.8" _ -10" RAILING 2'1o" ABV. ED E OF TR. I" NOSING TYP. (2) 6,5" RISERS + (1) II" rREAD = 24.6" POURED CONC. STAIR 1/2" GYP. SD. ON 2x FRAME WALLS AND 5/8" STUCCO ONMI-K. WALLS IN GARAGE 5/0" TYPE 11X11 GYP. BE). CL'G. W/ KNOCK-DN. FINISH v O N GARAGE 124" CLG, HT, CONC. FL. (NON -HABITABLE SP OMIT VENT AND IS EQ, RISERS a 1.315" = 11'O 3/4" RELOCATE TO RAILING 210" ABv, EDGE OF TR, GARAGE I" NOSING TYP. (2) 1,315" RISERS + (1) 10" TREAD = 24.15" 21' 0" I -3'1" FIN, FL O HYDROSTATIC O 5.92' N. .V.D VENTS 11211 AFF (MAX) - TYP. 5 PLACES I " I FIN. FL,,:h CONC. 6,0 N,A.V,D, PAVER I DRIVE Z I I I - 0 I ` I l� N I -4 I J I I q I - lu ^ I 0 N O I Z N _ O I x I I I _ O I I I O - I I p SETBA K I x F.G. 3' II w rYl POURED GONG. STAIR (o „ 40' I" N i�l-ll STAIR NOTE: 16' 10 10' 1" ■ PROPERTY LINE L = 12101 On W a O z � - > z -s z - �:, 6 Q d) (�/ O o D1 � cp .� .-� 3 N 0 t(1 N Q Zo 4 9 �`6 Q 4 Ow - �1 T 0 o-y w 9 zN z'-0u)�zo ff W T O (LO� 0 � �� U u 'Q O J 4 N �6 Q 3 S ."�+ U 4 a 2 0 3 3 m • U 04 E� A U 6 � M 0 6 0 U so cV 0 Cn �;) � U F >A N .. CD iir- Q zCIS 0 ty O O�� Cn T�l v ~ V w 0e4 PM O F • V DATE 06/25/21 DRAWN BY p jg me CHECKED MC REVISIONS 5/1-1/21 PER S,D, 9/10/21 PER S,D,