HomeMy WebLinkAboutAPPROVED KABLER- ENERGY CALC (1)EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 104/19/2021 12:54 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
KABLER RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
4912 WATERSONG WAY
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
3980
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.65 1098.30 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
9. Floor Types
a. Raised Floor
b. Slab-On-Grade Edge Insulation
c. N/A
R=19.0 2949.00 ft²
R=0.0 1031.00 ft²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=5.0 5489.00 ft²
b. Frame - Wood, Adjacent R=11.0 274.00 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 3980.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU 1 CLST
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Natural Gas Cap: 1 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:7.137 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
4
(1098.3 sqft.)
(5763.0 sqft.)
(3980.0 sqft.)
(3980.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
b. Central Unit
c. Central Unit
a. Electric Strip Heat
b. Electric Strip Heat
c. Electric Heat Pump
k B t u / h r
23.6 SEER:16.00
29.4 SEER:16.00
18.0 SEER:18.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
27.0 COP:1.00
18.0 HSPF:8.90
b. Sup: Attic, Ret: Attic, AH: UTILITY RM
f t ² R
6 130
6 140
Tankless
EF: 0.800
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.276
Total Proposed Modified Loads:
Total Baseline Loads:
156.76
161.78 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
4/22/2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
KABLER RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
3
3980
4
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
4912 WATERSONG W
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 AHU 1 1575 16852.5
2 AHU 2 1374 21235.2
3 MINISPLIT 1031 9486
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 LAUNDRY 70 749 No 0 Yes Yes1 Yes
2 OFFICE 120 1284 No 0 Yes Yes1 Yes
3 M BATH 186 1990 No 0 Yes Yes1 Yes
4 M WIC 150 1605 No 0 Yes Yes1 Yes
5 HALLWAY 123 1311 No 0 Yes Yes1 No
6 ELEV 2ND FLR 36 385 No 0 Yes Yes1 Yes
7 BATH 3 78 835 No 0 Yes Yes1 Yes
8 WIC 3 26 273 No 0 Yes Yes1 No
9 BEDROOM 3 175 1872.5 No 0 1 Yes Yes1 Yes
10 BEDROOM 2 187 2000.9 No 0 1 Yes Yes1 Yes
11 CLST 2 12 128 No 0 Yes Yes1 Yes
12 BATH 2 60 642 No 0 Yes Yes1 Yes
13 AHU 1 CLST 8 86 No 0 Yes Yes1 No
14 LINEN 4 43 No 0 Yes Yes1 No
15 M TOILET 18 193 No 0 Yes Yes1 Yes
16 MASTER BEDROO 322 3445.4 No 0 1 Yes Yes1 Yes
17 STAIRS 3RD FLR 88 2112 No 0 Yes Yes1 Yes
18 GREAT RM 324 5605 No 0 Yes Yes1 Yes
19 UTILITY RM 42 420 No 0 Yes Yes1 No
20 LIBRARY 180 2394 No 0 Yes Yes1 Yes
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
21 KITCHEN 364 6297.2 Yes 0 Yes Yes1 Yes
22 BEDROOM 4 196 2606.8 No 0 1 Yes Yes1 Yes
23 BATH 4 54 540 No 0 Yes Yes1 Yes
24 WIC 4 30 300 No 0 Yes Yes1 Yes
25 POWDER RM 36 360 No 0 Yes Yes1 Yes
26 ELEV. 3RD FLR 30 300 No 0 Yes Yes1 Yes
27 PANTRY 30 300 No 0 Yes Yes1 Yes
28 CABANA 78 702 No 0 Yes Yes1 Yes
29 MECH RM 36 324 No 0 Yes Yes1 Yes
30 ELEV 1ST FLR 36 324 No 0 Yes Yes1 Yes
31 FOYER 191 1719 No 0 Yes Yes1 Yes
32 STORAGE 690 6417 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 70 ft² 1 0 0______19Raised Floor 19 - - - - - - - -LAUNDRY
2 120 ft² 1 0 0______19Raised Floor 19 - - - - - - - -OFFICE
3 186 ft² 1 0 0______19Raised Floor 19 - - - - - - - -M BATH
4 150 ft² 1 0 0______19Raised Floor 19 - - - - - - - -M WIC
5 123 ft² 1 0 0______19Raised Floor 19 - - - - - - - -HALLWAY
6 36 ft² 1 0 0______19Raised Floor 19 - - - - - - - -ELEV 2ND FLR
7 78 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BATH 3
8 26 ft² 1 0 0______19Raised Floor 19 - - - - - - - -WIC 3
9 175 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BEDROOM 3
10 187 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BEDROOM 2
11 12 ft² 1 0 0______19Raised Floor 19 - - - - - - - -CLST 2
12 60 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BATH 2
13 8 ft² 1 0 0______19Raised Floor 19 - - - - - - - -AHU 1 CLST
14 4 ft² 1 0 0______19Raised Floor 19 - - - - - - - -LINEN
15 18 ft² 1 0 0______19Raised Floor 19 - - - - - - - -M TOILET
16 322 ft² 1 0 0______19Raised Floor 19 - - - - - - - -MASTER BEDRO
17 88 ft² 1 0 0______19Raised Floor 19 - - - - - - - -STAIRS 3RD FLR
18 324 ft² 1 0 0______19Raised Floor 19 - - - - - - - -GREAT RM
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
19 42 ft² 1 0 0______19Raised Floor 19 - - - - - - - -UTILITY RM
20 180 ft² 1 0 0______19Raised Floor 19 - - - - - - - -LIBRARY
21 364 ft² 1 0 0______19Raised Floor 19 - - - - - - - -KITCHEN
22 196 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BEDROOM 4
23 54 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BATH 4
24 30 ft² 1 0 0______19Raised Floor 19 - - - - - - - -WIC 4
25 36 ft² 1 0 0______19Raised Floor 19 - - - - - - - -POWDER RM
26 30 ft² 1 0 0______19Raised Floor 19 - - - - - - - -ELEV. 3RD FLR
27 30 ft² 1 0 0______19Raised Floor 19 - - - - - - - -PANTRY
28 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -25 ft CABANA
29 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -12 ft MECH RM
30 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -6 ft ELEV 1ST FLR
31 191 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -18 ft FOYER
32 690 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -71 ft STORAGE
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 4450 ft² Light 0.3 20 26.57______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 3980 ft² N N0
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 70 ft² 0.1 Wood______LAUNDRY Blown
2 Under Attic (Unvented)0 120 ft² 0.1 Wood______OFFICE Blown
3 Under Attic (Unvented)0 186 ft² 0.1 Wood______M BATH Blown
4 Under Attic (Unvented)0 150 ft² 0.1 Wood______M WIC Blown
5 Under Attic (Unvented)0 123 ft² 0.1 Wood______HALLWAY Blown
6 Under Attic (Unvented)0 36 ft² 0.1 Wood______ELEV 2ND FLR Blown
7 Under Attic (Unvented)0 78 ft² 0.1 Wood______BATH 3 Blown
8 Under Attic (Unvented)0 26 ft² 0.1 Wood______WIC 3 Blown
9 Under Attic (Unvented)0 175 ft² 0.1 Wood______BEDROOM 3 Blown
10 Under Attic (Unvented)0 187 ft² 0.1 Wood______BEDROOM 2 Blown
11 Under Attic (Unvented)0 12 ft² 0.1 Wood______CLST 2 Blown
12 Under Attic (Unvented)0 60 ft² 0.1 Wood______BATH 2 Blown
13 Under Attic (Unvented)0 8 ft² 0.1 Wood______AHU 1 CLST Blown
14 Under Attic (Unvented)0 4 ft² 0.1 Wood______LINEN Blown
15 Under Attic (Unvented)0 18 ft² 0.1 Wood______M TOILET Blown
16 Under Attic (Unvented)0 322 ft² 0.1 Wood______MASTER BEDRO Blown
17 Under Attic (Unvented)0 88 ft² 0.1 Wood______STAIRS 3RD FLR Blown
18 Under Attic (Unvented)0 324 ft² 0.1 Wood______GREAT RM Blown
19 Under Attic (Unvented)0 42 ft² 0.1 Wood______UTILITY RM Blown
20 Under Attic (Unvented)0 180 ft² 0.1 Wood______LIBRARY Blown
21 Under Attic (Unvented)0 364 ft² 0.1 Wood______KITCHEN Blown
22 Under Attic (Unvented)0 196 ft² 0.1 Wood______BEDROOM 4 Blown
23 Under Attic (Unvented)0 54 ft² 0.1 Wood______BATH 4 Blown
24 Under Attic (Unvented)0 30 ft² 0.1 Wood______WIC 4 Blown
25 Under Attic (Unvented)0 36 ft² 0.1 Wood______POWDER RM Blown
26 Under Attic (Unvented)0 30 ft² 0.1 Wood______ELEV. 3RD FLR Blown
27 Under Attic (Unvented)0 30 ft² 0.1 Wood______PANTRY Blown
28 Under Attic (Unvented)0 78 ft² 0.1 Wood______CABANA Blown
29 Under Attic (Unvented)0 36 ft² 0.1 Wood______MECH RM Blown
30 Under Attic (Unvented)0 36 ft² 0.1 Wood______ELEV 1ST FLR Blown
31 Under Attic (Unvented)0 191 ft² 0.1 Wood______FOYER Blown
32 Under Attic (Unvented)0 690 ft² 0.1 Wood______STORAGE Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 5 0LAUNDRY0806 10NW Concrete Block - Int Insul 0.30Exterior64.0 ft² ____
2 5 0OFFICE08010 10NW Concrete Block - Int Insul 0.30Exterior106.7 ft² ____
3 5 0M BATH 08012 10NE Concrete Block - Int Insul 0.30Exterior128.0 ft² ____
4 5 0M BATH 08014 10NW Concrete Block - Int Insul 0.30Exterior149.3 ft² ____
5 5 0M WIC 08015 10SE Concrete Block - Int Insul 0.30Exterior160.0 ft² ____
6 5 0ELEV 2ND FL 0806 10SE Concrete Block - Int Insul 0.30Exterior64.0 ft² ____
7 5 0BATH 3 0809 10SE Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
8 5 0BEDROOM 3 08014 10SE Concrete Block - Int Insul 0.30Exterior149.3 ft² ____
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
9 5 0BEDROOM 3 08014 10SW Concrete Block - Int Insul 0.30Exterior149.3 ft² ____
10 5 0BEDROOM 2 08013 10SW Concrete Block - Int Insul 0.30Exterior138.7 ft² ____
11 5 0BEDROOM 2 08013 10NW Concrete Block - Int Insul 0.30Exterior138.7 ft² ____
12 5 0CLST 2 0802 10NW Concrete Block - Int Insul 0.30Exterior21.3 ft² ____
13 5 0BATH 2 0806 10NW Concrete Block - Int Insul 0.30Exterior64.0 ft² ____
14 5 0M TOILET 0803 10NW Concrete Block - Int Insul 0.30Exterior32.0 ft² ____
15 5 0MASTER BE 08015 10NE Concrete Block - Int Insul 0.30Exterior160.0 ft² ____
16 5 0MASTER BE 08018 10SE Concrete Block - Int Insul 0.30Exterior192.0 ft² ____
17 5 0STAIRS 3RD 0008 24NW Concrete Block - Int Insul 0.30Exterior192.0 ft² ____
18 5 0GREAT RM 04013 17NE Concrete Block - Int Insul 0.30Exterior225.3 ft² ____
19 5 0GREAT RM 04024 17SE Concrete Block - Int Insul 0.30Exterior416.0 ft² ____
20 5 0LIBRARY04011 13SE Concrete Block - Int Insul 0.30Exterior146.7 ft² ____
21 5 0LIBRARY0406 13SW Concrete Block - Int Insul 0.30Exterior80.0 ft² ____
22 5 0KITCHEN04013 17NE Concrete Block - Int Insul 0.30Exterior225.3 ft² ____
23 5 0KITCHEN04028 17NW Concrete Block - Int Insul 0.30Exterior485.3 ft² ____
24 5 0BEDROOM 4 04011 13SE Concrete Block - Int Insul 0.30Exterior146.7 ft² ____
25 5 0BEDROOM 4 04014 13SW Concrete Block - Int Insul 0.30Exterior186.7 ft² ____
26 5 0BATH 4 0006 10SW Concrete Block - Int Insul 0.30Exterior60.0 ft² ____
27 5 0BATH 4 0009 10NW Concrete Block - Int Insul 0.30Exterior90.0 ft² ____
28 5 0WIC 4 0005 10NW Concrete Block - Int Insul 0.30Exterior50.0 ft² ____
29 5 0POWDER R 0006 10NW Concrete Block - Int Insul 0.30Exterior60.0 ft² ____
30 5 0ELEV. 3RD F 0005 10SE Concrete Block - Int Insul 0.30Exterior50.0 ft² ____
31 5 0PANTRY0005 10SE Concrete Block - Int Insul 0.30Exterior50.0 ft² ____
32 5 0CABANA0055 10NE Concrete Block - Int Insul 0.30Exterior54.2 ft² ____
33 5 0CABANA00013 9SE Concrete Block - Int Insul 0.30Exterior117.0 ft² ____
34 5 0CABANA0006 9SW Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
35 5 0MECH RM 0055 10NE Concrete Block - Int Insul 0.30Exterior54.2 ft² ____
36 5 0MECH RM 0006 9SE Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
37 5 0ELEV 1ST FL 0006 9SE Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
38 5 0FOYER00012 9SE Concrete Block - Int Insul 0.30Exterior108.0 ft² ____
39 5 0FOYER0006 9SW Concrete Block - Int Insul 0.30Exterior54.0 ft² ____
40 11 0FOYER0005 9NW Frame - Wood 0.30.1Garage45.0 ft² ____
41 11 0FOYER00013 9W Frame - Wood 0.30.1Garage117.0 ft² ____
42 5 0STORAGE00620 10NE Concrete Block - Int Insul 0.30Exterior205.0 ft² ____
43 5 0STORAGE04013 9SE Concrete Block - Int Insul 0.30Exterior121.3 ft² ____
44 5 0STORAGE04036 9NW Concrete Block - Int Insul 0.30Exterior336.0 ft² ____
45 11 0STORAGE04012 9SW Frame - Wood 0.30.1Garage112.0 ft² ____
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 32 ft² None______SW FOYER 84
2 Insulated .23 21.3 ft² None______W FOYER 882
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 NW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes1 Y
2 NW Low-E Single 0.65 0.25 36.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes2 Y
3 NE Low-E Single 0.65 0.25 15.0 ft² 9 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes3 Y
4 NE Low-E Single 0.65 0.25 36.0 ft² 9 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes3 Y
5 SE Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes7 Y
6 SW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y
7 SW Low-E Single 0.65 0.25 48.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y
8 SW Low-E Single 0.65 0.25 20.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes10 Y
9 SW Low-E Single 0.65 0.25 48.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes10 Y
10 NW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes13 Y
11 NW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y
12 NE Low-E Single 0.65 0.25 108.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y
13 SE Low-E Single 0.65 0.25 30.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes16 Y
14 NW Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes17 Y
15 NW Low-E Single 0.65 0.25 36.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes17 Y
16 NE Low-E Single 0.65 0.25 120.0 ft² 12 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes18 Y
17 SE Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes19 Y
18 SE Low-E Single 0.65 0.25 36.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes19 Y
19 SE Low-E Single 0.65 0.25 16.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y
20 SW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes21 Y
21 NE Low-E Single 0.65 0.25 120.0 ft² 12 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes22 Y
22 NW Low-E Single 0.65 0.25 16.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes23 Y
23 NW Low-E Single 0.65 0.25 48.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes23 Y
24 SW Low-E Single 0.65 0.25 4.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes25 Y
25 SW Low-E Single 0.65 0.25 12.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes25 Y
26 SW Low-E Single 0.65 0.25 8.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes25 Y
27 SW Low-E Single 0.65 0.25 48.0 ft² 8 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes25 Y
28 SW Low-E Single 0.65 0.25 4.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes26 Y
29 SW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes26 Y
30 NW Low-E Single 0.65 0.25 4.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes27 Y
31 NW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes27 Y
32 NW Low-E Single 0.65 0.25 4.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes29 Y
33 NW Low-E Single 0.65 0.25 8.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes29 Y
34 NE Low-E Single 0.65 0.25 21.3 ft² 9 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes32 Y
35 SE Low-E Single 0.65 0.25 4.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes33 Y
36 SE Low-E Single 0.65 0.25 20.0 ft² 8 ft 0 in 1 ft 4 in NoneMetal None______Yes38 Y
37 NE Low-E Single 0.65 0.25 24.0 ft² 9 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes42 Y
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
38 NE Low-E Single 0.65 0.25 96.0 ft² 9 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes42 Y
39 NW Low-E Single 0.65 0.25 20.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes44 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 704 ft² 704 ft² 30 ft 12 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
3963.7 5217.46.000379Wholehouse .1644408.25Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 17 kBtu/hr ______sys#1None1
2 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#2None2
3 Electric Heat Pump/HSPF:8.9 18 kBtu/hr ______DuctlessSplit3 Single
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 23.6 kBtu/hr 708 cfm 0.8______sys#1Split1 Single
2 Central Unit/SEER: 16 29.4 kBtu/hr 882 cfm 0.8______sys#2Split2 Single
3 Central Unit/SEER: 18 18 kBtu/hr 540 cfm 0.8______DuctlessSplit3 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Natural Gas 0.8 1 gal 55.1 gal 120 deg None______Tankless Garage
2 Natural Gas 0.8 1 gal 55.1 gal 120 deg None______Tankless Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 8 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 130 ft² Attic 13 ft² Prop. Leak Free AHU 1 CLS 47.3 cfm 0.03 0.50______1 1 --- cfm
2 Attic 6 140 ft² Attic 14 ft² Prop. Leak Free UTILITY R 41.2 cfm 0.03 0.50______2 2 --- cfm
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 OFFICE
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY
Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV 2ND FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 AHU 1 CLST
Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 STAIRS 3RD FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT RM
Default(8 lbs/sq.ft.f t ² f t 0.3 UTILITY RM
Default(8 lbs/sq.ft.f t ² f t 0.3 LIBRARY
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 4
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 4
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 4
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 9 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.f t ² f t 0.3 POWDER RM
Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV. 3RD FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY
Default(8 lbs/sq.ft.f t ² f t 0.3 CABANA
Default(8 lbs/sq.ft.f t ² f t 0.3 MECH RM
Default(8 lbs/sq.ft.f t ² f t 0.3 ELEV 1ST FLR
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 STORAGE
4/19/2021 12:54 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 10 of 10
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������