HomeMy WebLinkAboutPROJECT INFORMATION Ground Access Point F R-1 r # Modules (9) R Pitch: 42° Azimuth: 90°O N R-3 t T # Modules (12) Pitch: 20° Inverter Type: Enphase IQ7-60-2-US Azimuth: 90° PV Panel: (35)TSM335-DD06M.05(11) Racking: Chiko Rail o Total Wattage: 11,725W O Roof Type: Composition Shingles ° Wind Load: 20 to 45 Deg F Fastener Type: Use 5/16"Dia 4.75"Lags 2' Gutter Access Pathway Sheet Index S-1 Cover Sheet/ Site Plan -COGEN Disconnect a Located adjacent to S-2 Detail E-1 One - Line H 3' Access Pathway Utility meter S-1 A Mounting Plan O Utility Meter General Notes: L /7 /0 -Enphase IQ7-60-2-US Micro Inverters U R-2 are located on roof behind each module. # Modules (9) -First responder access maintained and S Pitch: 42° from adjacent roof. -Wire run from array to connection is 40 feet. Azimuth: 90° 3'-3 11 R-4 2' Gutter Access Pathway # Modules (5) 51-7]1� �! Pitch: 20° FLORIUOP W E R Azimuth: 180° Layout Subject to Change Based on Site Conditions M E M A NAG E N T Donnie C 1331 Green Forest Ct Ste 3 Godwin Engineering and Winter Garden FL, 34787 Godwin °81360 Design, LLC .:' N° 36a 407-926-0233 8378 Foxtail Loop 2021 .08.0 �. STATE of System meets the requirements of NFPA 70th Edition, Chapter 11.12 Install will be done to Manufacturer Spec -�T� p Pensacola, FL 32526 -,,SS 2 p,„BONA„�p Meets All Editions of Florida Fire Prevention Code 2020 7th Edition Customer Info: D. Chad Godwin, PE 16:04:49°ADONNIE Legend Chad@godwineng.com qp11 SEXED g � Chimney '00'05- R .NEE�Ro° ���Es First responder access Satellite I st Responder Access ❑0 Utility Meter O Vent Pipe Represents all Fire Clearance p Dorothy Johnson Date' 8/2/2021 N PV Disconnect including Alternative methods minimum of 36" unobstructed as per 1450 Co enhaver Rd Drawn b DL Section R324 of the 2018 IRC p Y� Meets the requirements of the following- (2020 FL Residential Code & FBC, 7th Edition (2018 Fort Pierce, FL Revised b �A International Residential Code) - 2nd Printing modified by the FL Building Standards , 2018 34945 Rev D International Energy Conservation Code, County of Saint Lucie Code, 2017 National Electric Code.) Rev Datee:: Page: S-1 Coin ass for Aerial Solar Module x HEXEX HEAD BOLT 5/8-16 FLANCE NUT 5/8 11 General Notes: R1-R2 General Notes: R3-R4 - Sunmodo Nano Mount are secured to rafters - Sunmodo Nano Mount are secured to rafters @ 48" O.C. in Zone 1, @ 48" O.0 in Zone 2e, @ 48" O.C. in Zone 1, @ 48" O.0 in Zone 2e, Install will be done to Manufacturer Spec @ 24" O.C. in Zone 2n, @ 48" O.C. in Zone 2r, @ 24" O.C. in Zone 2n, @ 24" O.C. in Zone 2r, @ 24" O.0 in Zone 3e, & @ 24" O.C. in Zone 3r @ 24" O.0 in Zone 3e, & @ 24" O.C. in Zone 3r Donnie C Godwin Engineering and `GN GOOD. using 5/16" x 4.75" stainless steel Lag bolts. using 5/16" x 4.75" stainless steel Lag bolts. Design, LLc Godwin °�: No 81360 - Subject roof has One layer. - Subject roof has One layer. 8378 Foxtail Loop 2021 .08. 37.7E OF ; Pensacola, FL 32526 02 'ass%oNA E� - All penetrations are sealed. - All penetrations are sealed. D. Chad Godwin, PE ° a'EE�EE" Chad@godwineng.com 16:05:10 µ E��RONL�PEs o0 Roof Section Pitch Roof Rafter and Spacing Overhang Notes: '00'05- R 1-R2 11/12 211x4" @ 24 O.C. 1211 Truss - -, FLaRII]`$P WER , E R3-R4 4/12 2" 12x4" @ 24 O.C. " Truss MA N A � T -Roof Height 20' Customer Info: 1331 Green Forest Ct, Ste 3 g Inverter Type: Enphase IQ7-60-2-US Winter Garden FL, 34787 -Per 2020 FBC, the Roof Mounted PV System PV Panel: (35) TSM335-DD06M.05(II) 407-926-0233 will be subject to the following design criteria: Racking: Chiko Rail Dorothy Johnson Date: 8/2/2021 Design Wind Speed(Vult) - 160mph 3 sec gust, Total Wattage: 11,725w 1450 Copenhaver Rd Drawn by: DL Exposure Category - C Roof Type: Composition Shingles Fort Pierce, FL Revised by: Wind Load: 20 to 45 Deg Rev #• 00 -Designed as per ASCE7-16 Fastener Type: Use 5/16" Dia 4.75" Lags 34945 Rev Date: Page: S-2 SOLAR PV SYSTEM EQUIPPED 3/8 IN MIN.TEXT WITH RAPID SHUTDOWN DUAL POWER SUPPLY INVERTER OUTPUT CONNECTION: Enphase Output Ckt Per String TURN RAPID SOURCES:UTILITY GRID AND DO NOT RELOCATE THIS SHUTDOWN SWITCH TC PV SOLAR ELECTRIC SYSTEM OVERCURRENT DEVICE 3116 IN MIN.TEXT THE"OFF'POSITION T To Overcurrent Protection Device SHUT DOWN PV AC Max Output Current 12 SYSTEM AND REDUCE Photovoltaics: SHOCK HAZARD IN THE AC Max Output Current * 1.25% 15 ARRAY. WARNING ! Enphase IQ Trunk Cable (35) TSM335-DD06M.05(II) POWER SOURCE OUTPUT CONNECTION: `t-12-240 Overcurrent Protection A 20 DO NOT RELOCATE THIS OVERCURRENT #12AWG THHN-THWN-2 No. of Current Carrying Cond <4 DEVICE UL 9703 Inverters: Conductor Gauge(AWG) 10 it PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 1 (35) Enphase IQ7-60-2-US Micro Inverters Enphase Total Output Ckt Grounding Conductor Circuits: AC Max Output Current 35 WARNING: g (2) circuits of(12) Modules AC Max Output Current* 1.25% 43.75 L CATED SOLAR PANEL DO to be bare#8 Aw •y CON I nADSECT NY OTHER (1) circuit of(11) Modules Overcurrent Protection(A) 50 NEMA 3R No. of Current Carrying Cond <4 Junction Box Roof Maximum Inverters Per 20A Circuit (16) Conductor Gauge (AWG) 6 #10 AWG THWN for Home runs Black-L1 (1)Line 1 Red-L2 (1)Line 2 NEC LABEL NOTES: Per Circuit Green-Ground 1. THE WARNING SIGN(S)OR LABEL(S)SHALL COMPLY WITH NEC 110.21(B) #8 AWG THWN 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT (1)EGC WHERE THEY ARE INSTALLED. Inside @ least 3/4"Conduit(tbd on site) 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8"AND WARNING PERMANENTLY AFFIXED. ELECTRIC SHOCK HAZARD Meter 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC DO NOT TOUCH TERMINALS. REQUIREMENTS OF THE AUTHORITY HAVING TERMINALS ON BOTH THE LINE AND JURISDICTION. LD LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION O Main Distribution Panel 200A Main Line Side Tap WARNING:PHOTOVOL POWER SOURCE RATED AC OUTPUT CURRENT: 35A NOMINAL OPERATING VOLTAGE: 240VAC Manual Lockable Disconnect 60A Service Rated Fused Disconnect Donnie C Enphase Combiner Box Neutral to Ground Bond AC Disconnect (1)-20A Breaker Godwin Engineering and Godwin SOA Fuse ���,�r'UOENSF'•�2�'c� Design, LLC Nu 81360 Per Circuit g ' 2021 .08. .�_ 3 C240iV 8378 Foxtail Loop %9: STATE 10/15A Breaker for Envoy Located Adjacent to Utility Meter " �: O H Disconnect Pensacola, FL 32526 02 ',ss . L#6 AWG THWN �./ON AI.E�.�` Solar Combiner Box #6 AWG THWN D. Chad Godwin, PE �rIraEEN'�"C. #X-I AM1-240 (1)Line 1 Q (1)Line 2 (')Line 1 Chad odwinen com 16:05:27 (1)Neutral (1)Line 2 �g g 1 "" �.E���""���"P�� ° 01 #8(1)EGC (1)Neutral _ in @least 3/4"Conduit Typically in @ least 3/4"Conduit Typically In Compliance with NEC 705.12(B) FLOR1o$P wEF Refer to NEC 312.8 for M A N , G�E M N T Conditions on taps in switch V and over current devices Enclosures. If the conditions are not 1331 Green Forest Ct, Ste 3 System meets the grounding requirements of NEC 690.43 met a tap box will needt°bein3ta11ed. Winter Garden FL, 34787 Including the label below GEC NOTES Customer Info• Note: - Ungrounded system per 690.41(A)(4) 407-926-0233 -All wiring to meet the 2017 NEC and - GEC must be installed per 250.64 Date• 8/2/2021 - GEC must be continuous un-spliced or irreversibly spliced from In Case of Emergency Call Florida electric codes. inverter to existing service ground system or continuous from the Dorothy Johnson Drawn b : DL Inverter Type: a 60A Disconnect arrays to the existing service ground system. y Enphase IQ7-60-2-US Florida Power Management - GEC must be min#8 AWG and installed in conduit 1450 Copenhaver Rd Revised b • PV Panel: -Type of conduit to be determined - If GEC is not in conduit,it must be#6 min (35) at 407-926-023 3 on site by contractor. Disconnects will be Visible,lockable,adjacent to Fort Pierce, FL Rev #: 00 TSM335-DD06M.05(Il) and within 10'of utility meter 34945 Rev Date: Total Wattage: All Labels&Markings for photovoltaic system will be 11,725W Install will be done to Manufacturer Spec reflective and meet all requirements for NFPA 11.12 Page: E-1 ( — Proposed Mounting locations 14'- 10" 14'-611 - 18'-311 0 0 0 0 © 000 O OL L Q OL 711- - 19' 0_7�� L L 19'_7'► L L L 191_41� 0 o L 291_711 L 0 L 0 0 0 0 0 L L �� L 0 L 0 L L p © L L L 0 0 0 L L 7' 1 1 11 L D 1 1 o \0 R_1 R-2 361_811 # Modules 9 R-3 R-4 O # Modules (9) # Modules (5) Pitch: 420 Pitch: 420 # Modules (12) Pitch: 20° Pitch: 20° 3'-3" Azimuth: 900 Azimuth: 900 Azimuth: 180° Azimuth: 90° 5'-7" Plans satisfy zones FBC-1510.7.1 Install will be done to Manufacturer Spec Donnie C Godwin Engineering and GLAD Gp� Max cantilever is 16 as per manufacturers spec. Design, Godwin Z. 81360 Desi n LLC No 81360 ' Chiko Rail RI-R2 Zone 1, 2e & 2r: p p 8378 Foxtail Loo 2021 .08. 9: �= �C 11�. it p STATE OF �/: 14 21 Max Cantilever = Max Span (3)=48 (3)=16 Pensacola, FL 32526 02 S%oNA°E ;��, t 1 �'' nn n n,n„ Max cantilever is 8 as per manufacturer spec. D. Chad Godwin, PE R1-R2 Zone 2n, 3e & 3r: 1 1 16:05:39 Aa Max Cantilever = Max Span * (3)=24 *(3)=8 Chad@godwineng.com 100105 1 Alo A� Eo�o.Io op s Max cantilever is 16" as per manufacturer spec. 00 05- E R3-R4 Zone 1 & 2e: Max Cantilever = Max Span * (3)=48"*(3)=16" -��� Splice Bar 2 p p FLDR �IlP WER Max cantilever Is 8 as per manufacturers spec. Sunmodo NanoMounts 85 R3-R4 Zone 2r, 2n, 3e & 3r: * 1 _ tl* I _ It M A µ G E M E N T Chiko Mids 50 Max Cantilever = Max Span (�)-24 (3)-8 1331 Green Forest Ct, Ste 3 Chiko Ends/End Caps 40 Customer Info: Winter Garden FL, 34787 Combiner 4 Inverter Type: Enphase IQ7-60-2-US 407-926-0233 Chiko Ground Lugs 10 PV Panel: (35) TSM335-DD06M.05(II) TSM335-DD06M.05(II Racking: Chiko Rail Dorothy Johnson Date: 8/2/2021 � 35 Enphase IQ7-60-2-US 35 Total Wattage: 11,725W 1450 Copenhaver Rd Drawn by: DI. 60A Fused Disconnect I Roof Type: Composition Shingles Fort Pierce FL Revised by: 50A Fuses 2 Wind Load: 20 to 45 Deg 34945 Rev #: 00 20A Breakers 3 Fastener Type: Use 5/16" Dia 4.75" Lags Rev Date: Enphase Combiner Box I Page: S-1 A Mono Multi Solutions esi ent'a ule MULTI-BUSBAR 120 HALF-CELL BOB MODULE THE DIMENSIONS OF PV MODULE(mm) ELECTRICAL DATA(STC) Peak Power Watts-PMAx(Wp)" 310 315 320 325 330 335 Residential Module Power Output Power Tolerance-PM p(V) 0_+5 Maximum Power Voltage-VNca(V) 33.0 33.2 33.4 33.6 33.8 34.0 4-09x14 InsfallingHole Maximum Power Current-IMFF(A) 9.40 9.49 9.58 9.67 9.76 9.85 MULTI-BUSBAR120 HALF-CELL BOB MODULE Open Circuit Voltage-Voc(V) 39.9 40.1 40.3 40.4 40.6 40.7 Short Circuit Current-Isc(A) 10.03 10.12 10.20 10.30 10.40 10.50 604.3 Module Efficiency n rr(%) 18.2 18.5 1B.8 19.1 19.4 19.7 Grounding H°le STC Irradiance 1000W/m2,Cell Temperature 25°C Air Mass AM1.5. PRODUCTS BACKSHEET POWER Is- H°le Maa,.rmgt.lerance:±3%. Ce I I COLOR RANGE 1 Z 0 TSM-DD06M.05(11) Black 310-335W ELECTRICAL DATA(NMOT) MONOCRYSTALLINE MODULE FRAME COLOR: Black String Inverter Configuration Maximum Power-PMAx(Wp) 235 238 242 246 250 254 1 959 Maximum Power Voltage-VMca(V) 31.0 31.2 31.4 31.6 31.7 31.9 3 i O-3 3 5 W Maximum Power Current-InHc(A) 7.57 7.64 7.71 7.79 7.86 7.94 Open Circuit Voltage-Vocv) 37.6 37.8 38.0 38.1 38.3 38.4 High power Short Circuit Current-Isc(A) 8.08 8.15 8.22 8.30 6.38 8.46 POWER OUTPUT RANGE 4-09x • Reduce BOS cost with high power bin and module efficiency nnallin14g Hule NMOT:Irradiance at BOOW/pl Ambient Temperature 20°G Wind Speed louts. • New cell string layout and split J-box location reduces the energy loss A 'A ��n1. cause y Inter-row shading MECHANICAL DATA 19 7% • Lower resistance of half-cut cells and increased MBB(Multi Busbar) ■ Solar Cells Monocrystalline reflectance ensure higher power o`, ding H°le MAXIMUM EFFICIENCY Cell Orientation 120 cells(6x 20) I2-Drain Hole High energy generation,low LCOE Module Dimensions 1696 x 1004 x 35 mm(66.85x 39.53 x 1.38 inches) Weight 16.7kg(41.21b) 0 N +5 W • Excellent 3rd party validated IAM and low light performance with cell Microinverteror Opt!mizerConfiguration Glass 3.2mm(0.13 inches),High Transmission,AR Coated Tempered Glass Y Y process and module material optimization Encapsulant Material EVA POSITIVE POWER TOLERANCE • Low Pmax temp coefficient(-0.36%)increases energy production SIIIrnnSealant r '"'"at° Backsheet Black • Better anti-shading performance and lower operating temperature Frame 35 mm(1.36 inches)Anodized AluminiumAlloy Founded in1997,TrinaSolaristheworld'sleading name total solution providerfor solar energy.With local Outstanding visual appearance,easy to install J-Box IP68rated presence around the globe,Trina Solar is able to 33 2q.1 provide exceptional service to each customer in A-A B-B Cables Photovoltaic Technology Cable 4.Omm2(0.006 inches2) each market and deliver our innovative,reliable - • Designed for superior rooftop aesthetics Portrait:N140mm/P285mm(5,51/11,22 inches) products with the backing of Trina as a strong, I-V CURVES OF PV MODULE(335W) bankable brand.Trina Solar now distributes its PV •Thinner wires give a eye cacthing all black look 11.0 Landscape:N 1200 mm/P 1200 mm(47.24/47.24 inches) products to over 100 countries all overthe world. • Safe and easy to transport,handle,and install °° 9.0 We are committed to building strategic,mutually ao Connector MC4 beneycial collaborations with installers,developers, J0 energyto ether.other partners in driving smart Certified to perform in highly challenging environments 6A s0ow,m energytogether. so d 4.0 400P7Tm TEMPERATURE RATINGS MAXIMUM RATINGS • High PID resistance through cell process and module material control a.o 2' 200- -A0 Comprehensive Products Resistant to salt,acid,sand,and ammonia =° NMOT(N°min,l Mucci,Op-ti"9T-Perature) 410C(±30C) Operational Temperature -40-+85°C and System Certificates • Over 30 in-house tests(UV,TC,HF etc) 0 to 20 30 a0 s0 Temperature Coefficient OfPMAx 0.360/o/°C Maximum System Voltage 1000VDC(IEC) IEC61215/IEC61730/IEC61701/IEC62716 • Certified to 5400 Pa positive load and 2400 Pa negative load Voltage(V) Temperature Coefficient of Voc -0.26%o/°C 1000V DC(UL) ISO9001:Quality Management System P-V CURVES OF PV MODULE(335W) 0 ISO 14001:Environmental Management System Temperature Coefficient of Ise 1 0.04/o/°C Max Series Fuse Rating 20A IS014064:Greenhouse Gases Emissions Veri cation 350 r000wim Y (Do not connect Fuse in Combiner Box with two or more strings in parallel connection) OHSAS 18001:Occupation Health and Safety PERFORMANCE WARRANTY 300 Management System z50 10 Year Product Warranty•25 Year Power Warranty 3 200 e0owim WARRANTY PACKAGING CONFIGURATION _ ED g 150 400W""' 10year Product Workmanship Warranty Modules per box:30 pieces LISTED 97.5% ■ Trina Standard 100 zoowim� 25 year Power Warranty Modules per 40'container:780 pieces 50 C At 90% Pleaserefertoprodu twarrantyfordetails) 0 10 2n 30 q0 30 Voltage(V) L91 V 83.1% boom u' Years 5 10 15 20 25 CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. From the end year to the 25th year,the average annual power decline will be no more than o,e iTrinasolar Trinasolar m 2019 Trina Solar Limited.All rights reserved.Speciycations included in this datasheet are subject to change without notice. Version number:TSM_DD06M.05(II)_EN_2019_B www.trinasolar.com Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V The high-powered smart grid-ready Max DC short circuit current(module Ise) 15 A 15 A Overvoltage class DC port 11 11 Enphase Enphase IQ 7 MicroTM and Enphase IQ 7+ MicrOTM DC port backfeed current 0 A 0 A Q 7 and I Q 7 dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak Microinverters Part of the Enphase IQ System,the IQ 7 and Maximum umcontinutput 240 VA 290VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L-L)voltage/ranger 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'"', Enphase IQ Battery'"", and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'"" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype(I07-60.2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) Connector type(I07-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: • Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure • Class 11 double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor • UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break Complies with advanced grid support,voltage and disconnect required by NEC 690. _ frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. U *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/su000rt/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. E N P H AS E® To learn more about Enphase offerings,visit enphase.com E N PHASE. To learn more about Enphase offerings,visit enphase.com u �./ ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 Data Sheet Enphase IQ Combiner 3 Enphase Networking MODEL NUMBER IQ Combiner 3 X-I0-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-MI(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Enphase The Enphase IQ Combiner 3" with Enphase Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). IQ EnvoyTM consolidates interconnection Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. IQ Combiner 3 equipment into a single enclosure and BRK-10A-2-240 Circuit breaker,2 pole, 10A,Eaton BR210 v g BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 (X-I AM1-240-3) g y BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 Q- streamlines PV and storage installations b EPLC-01 Power line carrier(communication bridge pair),quantity 2 providing a consistent, pre-wired solution for XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) residential applications. It offers up to four XA-ENV-PCBA-3 Replacement 10 Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS 2-pole input circuits and Eaton BR series Rating Continuous duty busbar assembly. System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64 A Smart Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy j) Includes IQ Envoy for communication MECHANICAL DATA and control — - -—- —— — — -- --Flexible networking supports Wi-Fi, — Dimensions(W%HxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6,63"),Height is 21,06"(53.5 cm with mounting brackets). • Ethernet,or cellular Weight 7.5 kg(16.5 Ibs) t I I Ambient temperature range -400 C to+461 C(-400 to 1150 F) Optional AC receptacle available for PLC ? bridge Cooling Natural convection,plus heat shield - Provides production metering and optional Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction consumption monitoring Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors •"I 1 60 A breaker branch input: 4 to 1/0 AWG copper conductors IMain lug combined output: 10 to 2/0 AWG copper conductors Simple Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. — I Reduced size from previous combiner Altitude To 2000 meters(6,560 feet) Centered mounting brackets support single INTERNET CONNECTION OPTIONS stud mounting Integrated Wi-Fi 802.11b/g/n • Supports back and side conduit entry Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) • Up to four 2-pole branch circuits for 240 VAC Cellular Optional,CELLMODEM-01 (3G)or CELI-MODEM-03(4G) or CELLMODEM-M I(4G based LTE-M) plug-in breakers(not included) (not included) • 80 Atotal PV or storage branch circuits COMPLIANCE Compliance,Combiner UL 1741 CAN/C Reliable 47CFRSPart 15,Class B,ICES 003 Production metering-ANSI C12 20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure U • Five-year warranty *Consumption monitoring is required for Enphase Storage Systems. o ` UL listed To learn more about Enphase offerings,visit enphase.com LISTED E N P H AS E ©2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. E N P H AS E® To learn more about Enphase offerings,visit enphase.com 2018-09-13 �m� 0H I K NW -® CHIKQQUSA k. Solar Mounting Solutions RACKING MADE SIMPLE Series 7R Rail PRODUCT LINE � Item Product Name Chiko's 7R Rail has been designed to achieve industry leading span lengths. With our leading span lengths,you can reduce the number CK-7R-2560 CHIKO 7 RAIL 2560MM of attachments and roof penetrations on every install. Chiko's 7R '�- CK-7R-3200 CHIKO 7 RAIL 3200MM Series rail is available in both a silver aluminum and an anodized CK-7R-3405 CHIKO 7 RAIL 3405MM black color option. r CK-7R-4200 CHIKO 7 RAIL 4200MM The following engineering values were determined using Building Code and --- Methodology:2012/2015 IBC&ASCE 7-10. Building height not to exceed 30'with a PRODUCTLINE module tilt flush with roof whereas roof tilt range is between 7°and 27 Exposure B, Main Material AL 6005-T5 Roof Zone 1,Risk Category II. Wind Velocity Up to 60 M/S 7R Rails - Risk Cat. II Portrait 7 ��I� Xi=31918.082 mm4 70 < Slope s 270 Yi=81501 .592 mm4 Max Rail Spans(ft) CHIKO 7R aluminium rail is designed for Zone 1 wind Ground Snow Load (psf) roof mounting system, it could applied on Speed Exposure I 0 10 20 30 40 50 60 70 80 90 all roof mount system, 110 4.0 4.0 4.0 3.0 3.0 COMPONENT LIST WARRANTY 115 . , ' , , 4.0 4.0 4.0 3.0 3.0 MATERIAL OTY B 130 : 4.0 4.0 4.0 3.0 3.0 Aluminium Rail 01 150 I 4.0 4.0 4.0 3.0 3.0 170 I 4.0 4.0 4.0 3.0 2.0 200 4.0 4.0 4.0 3.0 2.0 ADVANTAGES 7R Rails - Risk Cat. II landscape ■ Easy installation ORDERING SPECIFICS Max Rail Spans(ft) 70 < Slope <_ 270 ® Highclass anodized Zone 1 ■ Tilt- in nut Standard Packaging 8 PCS/PKG Wind Ground Snow Load(psf) ■ Universal on roof mount system Dimensions 2560/3200/3405/4200mm Exposure Speed 0 10 20 30 40 50 60 70 80 90 Weight 18/22.8/24.5/30KG 110 6.0 6.0 5.0 5.0 4.0 115 6.0 6.0 5.0 5.0 4.0 B 130 r 6.0 6.0 5.0 5.0 4.0 150 I 6.0 6.0 5.0 5.0 4.0 170 I 6.0 6.0 5.0 4.0 3.0 200 I 6.0 6.0 5.0 4.0 3.0 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop,Pensacola, FL 32526 1 (850)712-4219 1 chadogodwineng.com August 2,2021 To: St. Lucie County Building Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Johnson-Residential PV Roof Mount Installation 1450 Copehaver Rd. Fort Pierce, FL 34945 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above.I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2020 Florida Building Code 7th Edition,FBC ASCE 7 Min. Design Loads for Buildings&Other Structures Per 2020 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V„lt) - 160mph 3sec gust, Exposure Category- C The PV System consist of the modules,railing,and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. Y2"plywood decking and 2"x 4" roof trusses 24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Chiko railing and the Sunmodo Nano mounts. In R1-R2,the attachments can be attached up to 48" apart in roof zones 1, 2e, 2r, 24"apart in roof zones 2n, 3e,and 3r. In R3-R4,the mounts can be attached up to 48"apart in roof zones 1, 2e,and 24" apart in roof zones 2n, 2r, 3e,&3r.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with a min.5/16"lag screw with minimum 2-5/16"thread length. Please see attached documents and contact me should you have any questions. Sincerely Donnie C Godwin No 81360 D. Chad Godwin,PE 81360 p / / 2021 .08.02 Ex . 02 28 2023 'p'•• STATE OF 1 ........� 6:05:56 THIS ITEM HAs BEEN ELECTRONICAUY SIGNED AND SEALED BY DONNIE CHAD '00'05- a oDwlN�o�sDE os�NEo"aNOG AND THE SIGNATURE MUST BE VERIFIED ON ASCE 7-16 CHAPTER 29 WIND LOADS-Rooftop Solar Panels Minimum Design Loads-Part 1:Enclosed(gable,h<60ft,210<6<270) Risk Category II Table 1.5-1 Load Types Load,PSf Basic Wind Speed(Ult) 160 mph Figure 26.5-113 Dead Load,D 3 Wind Speed(asd) 124 mph FRC R301.2.1.3 Weight of Ice,Di 0 Roof Angle 21 to 27 Earthquake,E 0 Effective Wind Area 18.15 ftZ 26.20 Fluid,F n/a Wind Load Parameters Flood Load,Fa n/a Wind Directionality Kd 0.85 Table 26.6-1 Lateral Earth psi,H n/a Exposure Cat. B,C,or D C Section 26.7 Live Load,L n/a Topographic factor Kzt 1.00 26.8 or 26.8.2 Roof Live,Lr n/a Ground Elevation Factor Ke 1.00 Table 26.9-1 Rain,R n/a Velocity Exposure Coefficient Kz 0.90 Table 26.10-1 Snow,S Array Edge Factor yE 1.50 29.4.4 *Modules are considered Exposed Self-Straining,T n/a Solar Panel Equalization Factor ya 0.70 Fig.29.4-8 Wind,W see calc Velocity Pressure qp 30.08 psf qh=0.00256 K,Kz KdKeVZ Wind-on-Ice,Wi n/a Mean Roof Height h 20.00 ft hz 5 in Not>10in(height above roof) 0.4h 8.00 ft 2h2 10 In *min distance array shall be from the roof edge,Gable Ridge,or hip ridge least horizontal dim(typ.) In 0.25 In min gap between all panels but not>5.7ft 10%of least horizontal dimLE ft d1 1.00 ft Horizontal distance orthogonal to panel edge Roof Zone Set Back a ft d2 0.25 ft Horizontal distance from edge of one panel to the nearest edge in the next row 0.5h 10.00 ft 1.51-p 8.38 ft Figure 30.3-2C(Gable roof,h<60ft,21°<0<27°) Zone 1 2e 2n 2r 3e 3r GCp -1.50 1 -1.50 1 -2.10 1 -2.10 1 -2.10 1 -2.30 uplift GCp 0.50 1 0.50 1 0.50 1 0.50 1 0.50 1 0.50 downward p=gh(GCp)(yE)(-/j -47.14 -47.14 -66.00 -66.00 -66.00 -72.28 psf uplift 29.4-7 p=gh(GCp)(yE)(-yj 15.71 15.71 15.71 15.71 15.71 15.71 psf downward 29.4-7 Design Calculations for the Use of Attachment to Roof Truss/Rafter Module Length C(Lp) 5.58 ft Module Width B ft Module Area A 18 ftz Total Design Load(Uplift) Pdesign -44.14 -44.14 -63.00 -63.00 -63.00 -69.28 psf Total Design Load(Downforce) Pdesign 18.71 18.71 18.71 18.71 18.71 18.71 psf Design Load per Module TBp -800.96 -800.96 -1143.11 -1143.11 -1143.11 -1257.17 Ibs T p=A*Pdesign Design Load per Module Tdown 339.57 339.57 339.57 339.57 339.57 339.57 Ibs Tan=A*Pdesign Distributed Load(Uplift) Pdist.up -123.22 -123.22 -175.86 -175.86 -175.86 -193.41 plf T p/B*2 Distributed Load(Down) Pdist.Down 52.24 52.24 52.24 52.24 52.24 52.24 plf Tdn/B*2 Railspan Between Anchor Points L 4 4 2 2 2 2 ft Point Load per Mount(Uplift) R -492.90 -492.90 -351.73 -351.73 -351.73 -386.82 Ibs Point Load per Mount(Down) R 104.48 104.48 52.24 52.24 52.24 52.24 Ibs Table 1.1-Pullout Value for Single Lag Screw Specific Gravity G 0.55 0.55 0.55 0.55 0.55 0.55 Table 11.2A,NOS 2005,page 68(SYP) Diameter of Lag Screw D 5/16 5/16 5/16 5/16 5/16 5/16 In 5/16"typ. Pullout Value of W 306.8697 306.8697 306.8697 306.8697 306.8697 306.8697 Ibs/in W=1800 G3/2 D3/a #i of Lag screws 1 1 1 1 1 1 Thread Length Td 2.3125 2.3125 2.3125 2.3125 2.3125 2.3125 In Table L2,NDS 2005 Design Pullout Value per Mount Wt 709.6363 709.6363 709.6363 709.6363 709.6363 709.6363 Wt=W*#of Lags*Td SAFTEY FACTOR SF 1.44 1.44 1 2.02 1 2.02 1 2.02 1.83 Calculation:SF=WUR(Uplift) 1 2e 2n 2r 3e 3r Maximum Cantilever from Last attachment Max Cantilever M 16 16 8 8 8 8 in Max rail span*33% all Donnie C JQ.:��OEN3F.•Gy. Godwin No 8136° 2021 .08.02 .?�• STATE OF `Gl C7 ONA� 16*0 V o V THIS REM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY DONNIE CHAD C GOD IN USING A DIGITAL SIGNATURE AND CAT.PR COPIES OF THIS DOCUMENT NTED '00'OJ EALED AND THEISGNATURE MUIST GNED BE VERIAND FIED ON ANY ELECTRONIC COPIES