Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE5' J FOIFW R405-2020 dQNftR1Y�CTION FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING Florida Department of Business and Professional Regulation - Residential Per _ nc�Nlethod 001� Project Name: Lot 174 Phase 3 Waterstone 1780 AGL Builder Name: ADAMS HOMES Street: 5321 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1512.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1244.60 ft2 b. Frame - Wood, Adjacent R=13.0 268.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1780.00 ft2 6. Conditioned floor area above grade (ft2) 1780 b. Knee Wall (Vented) R=19.0 120.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(177.0 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 356 a. U-Factor: Dbl, U=0.33 113.31 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 45.94 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGCng Area Weighted Average Overhang Depth: 2.639 ft. D 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.272 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1780.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 52.37 PASS Total Baseline Loads: 52.91 I hereby certify that the plans a s cations covered b of the plans and this calculation are in compli c the Florid gy specifications covered by this p Code. calculation indicates compliance , y.' iil,��' _ �,.�`. A •. with the Florida Energy Code. PREPARED BY: Before construction is completed t DATE: nR n7-9n91 Winn KPnmany this building will be inspected for compliance with Section 553.908•. I hereby certify that this building, as designed, is in compliance Florida Statutes.: 5 with the Florida Enersl I Code. OWNER/AGEN BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an } envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 6/7/2021 4:25 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 174 Phase 3 Waterstone Bedrooms: 3 User Conditioned Area: 1780 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 174 Block/Subdivision: Waterstone PlatBook: Street: 5321 Vespera Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1780 15664 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0 1780 ft2 ---- 0.38 0 0.62 ROOF / # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1990 ft2 446 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Knee Wall (Vented) Under Attic (Vented) Main 19 Batt Main 30 Blown 120 ft2 0.11 Wood 1780 ft2 0.11 Wood 6/7/2021 4:25 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPf)RT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 320.0 ftZ 0 0 0.6 0 _ 2 N Exterior Concrete Block - Int Insul Main 4.1 40 6 8 0 324.0 ftZ 0 0 0.6 0 3 NW Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ftZ 0 0 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 11 9 9 6 111.6 ftZ 0 0 0.6 0 5 SW Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ftZ 0 0 0.6 0 6 S Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 ftZ 0 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 268.0 ftZ 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ftZ 2 - Wood Main None .25 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftZ 14 ft 4 in 0 ft 10 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 4 NW 3 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 5 W 4 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 6 SW 5 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 7 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftZ 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter. Avg. Wall Height Exposed Wall Insulation 1 391 ftZ 391 ftZ 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 1827.5 100.26 188.23 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 28.2 kBtu/hr 1 sys#1 6/7/2021 4:25 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPl1T RIIMMARY rl-IFrKI IRT RI=Pf1RT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- V ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ftz Main 89 ftz Proposed Qn Main --- cfm 124.6 cfm 0.07 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinH Jan H Feb Mar Mar HX Apr Apr I Jul May Jun Jul may ri Jun rl AuSep ri Aug Se ri Oct Oct Nov Nov HX Dec Dec H Ventin Jan Feb Mar [X] Apr May JunJul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main 6/7/2021 4:25 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM. R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 5321 Vespera Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1244.60 ft2 b. Frame - Wood, Adjacent R=13.0 268.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1780.00 ft2 6. Conditioned floor area (ft2) 1780 b. Knee Wall (Vented) R=19.0 120.00 ft2 7. Windows"* Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 113.31 ft2 12. Ducts, location &insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 356 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 45.94 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 2.639 ft. Area Weighted Average SHGC: 0.272 8. Skylights Description Area 15. Hot water systems. Cap: 40 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 4:25 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1