HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEMPV-1 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 THIS PROJECT COMPLIES WITH THE FOLLOWING: 2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL 2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING 2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION 2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY 2020 NATIONAL ELECTRIC CODE (NEC) AS ADOPTED BY ST. LUCIE COUNTY SITE LOCATION CODES: VICINITY MAP: TABLE OF CONTENTS: CONSTRUCTION NOTES: PHOTOVOLTAIC SYSTEM PV-1 SITE LOCATION PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-2B STRUCTURAL CALCULATIONS PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 CONDUCTOR CALCULATIONS PV-6 EQUIPMENT & SERVICE LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2020 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2020 NEC THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. SITE LOCATION THIS SYSTEM IS DESIGNED FOR WIND SPEED: 152 MPH CATEGORY C EXPOSURE GREG ALBRIGHT MSP UM AC INV JB SITE PLAN SCALE: 3/32" = 1'-0"1 ROOF LINE PROPERTY LINE DRIVEWAY PICANTE CIRCLE(E) MAIN SERVICE PANEL (N) 17 LONGI SOLAR: LR4-60HPB-350M (E) UTILITY METER (N) JUNCTION BOX PV SYSTEM 5.950 kW-DC 5.000 kW-AC (N) SOLAREDGE SE5000H-USRGM [SI1] INVERTER WITH RAPID SHUTDOWN (N) AC DISCONNECT EATON DG221URB PV-2 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 ROOF AREA: 2715 SQ FT SITE PLAN LEGEND: OBSTRUCTION PIPE VENT MODULES CONDUIT SETBACK MSP AC JB AC DISCONNECT MSP JUNCTION BOX INV INVERTER PM PRODUCTION METER GREG ALBRIGHT 92'-11"53'-0"92'-11"53'-0"4'-10"23'-9"12'-3"2'-9" MSP UM AC INV JB PV-2A FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 ROOF PLAN SCALE: 1/8" = 1'-0"1 FIRE ACCESS PATHWAYS(N) 17 LONGI SOLAR: LR4-60HPB-350M (E) UTILITY METER PV SYSTEM 5.950 kW-DC 5.000 kW-AC NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF AREA: 2715 SQ FT ROOF PLAN WITH MODULES LAYOUT LEGEND: OBSTRUCTION PIPE VENT MODULES CONDUIT SETBACK MSP AC JB AC DISCONNECT MSP JUNCTION BOX INV INVERTER PM PRODUCTION METER GREG ALBRIGHT FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS 3'-0"3'-0"3'-0"3'-0" By Yuri at 10:10:03 AM, 9/2/2021 ROOF AREA STATEMENT ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA 117 22° 22° 181°925 SQ FT 306.85 SQ FT PV-2B FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 ROOF DETAILS: TOTAL ROOF AREA: 2715 SQ FT ARRAY COVERAGE: 11.30% SYSTEM DISTRIBUTED WEIGHT: 2.31 LBS S-5!: PROTEA POINT-LOAD: 22.85 LBS S-5!: PROTEA POINT-LOAD: 22.85 LBS ROOF DETAILS GREG ALBRIGHT By Yuri at 10:10:05 AM, 9/2/2021 PROTEABRACKET PROTEABRACKET (E) TRAPEZOIDAL METAL ROOF PROFILE 1" SELF TAPPING SCREW FACTORY APPLIED EPDM WITH STICKY ADHESIVE (E) TRAPEZOIDAL METAL ROOF PROFILE (N) LONGI SOLAR: LR4-60HPB-350M UNIRAC SM LIGHT RAIL GROUNDING END/MID CLAMP 2X4 TRUSS @ 24" O.C. 0 RACKING SYSTEM (N) LONGI SOLAR: LR4-60HPB-350M (E) METAL SEAMS @ 12" O.C. ROOF ATTACHMENT 4' ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PARTIAL ROOF FRAMING PLAN Scale: NTS PV-3 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 MOUNTING DETAILS GREG ALBRIGHT MAX ATTACHMENT SPAN - 4' STAGGERED By Yuri at 10:10:07 AM, 9/2/2021 SOLAREDGE P401 POWER OPTIMIZERS JUNCTION BOX STRING-1 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT STRING-2 SOLAREDGE P401 POWER OPTIMIZERS 2 - #10 AWG, PV WIRE 8 LONGI SOLAR: LR4-60HPB-350M 9 LONGI SOLAR: LR4-60HPB-350M 4 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT UM(E) 150A / 2P MAIN BREAKER (TOP FED) (E) 150A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER (N) 30A / 2P PV BREAKER TO UTILITY UNDERGROUND FEED 3 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) 30A RATED AC DISCONNECT EATON DG221URB KNIFEBLADE, LOCKABLE, NEMA 3R, UL LISTED 3 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) SOLAREDGE SE5000H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH CONNECT TO EXISTING UFER NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED BREAKER SIZING MAX. CONTINUOUS OUTPUT 21.00A @ 240V 21.00 X 1.25 = 26.25AMPS 30A BREAKER - OK SEE 705.12 OF 2020 NEC 150 X 1.20 =180 180 -150 = 30A ALLOWABLE BACKFEED PV SYSTEM 5.950 kW-DC 5.000 kW-AC PV-4 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 THREE LINE DIAGRAM GREG ALBRIGHT PV-5 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 CONDUCTOR CALCULATIONS GREG ALBRIGHT WIRE SCHEDULE RACEWAY #EQUIPMENT WIRE LOCATION CONDUCTOR QTY. AWG WIRE SIZE STARTING ALLOWABLE AMPACITY @ 90°C 310.15(B)(16) STARTING CURRENT APPLIED TO CONDUCTORS IN RACEWAY TEMPERATURE CORRECTION FACTOR 310.15(B)(2)(a) ADJUSTMENT FACTOR FOR MORE THAN 3 CONDUCTORS 310.15(B)(3)(a) ADJUSTED CONDUCTOR AMPACITY @ 90°C MAXIMUM CURRENT APPLIED TO CONDUCTORS IN RACEWAY 1 DC MODULE TO OPTIMIZER ROOF / FREE-AIR 210 40 13.95 1 1 40.00 17.44 2 DC OPTIMIZER TO JUNCTION BOX ROOF / FREE-AIR 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER EXTERIOR WALL 4 10 40 15.00 1 0.8 32.00 18.75 4 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 10 40 21.00 1 1 40.00 26.25 5 AC AC DISCONNECT TO POI EXTERIOR WALL 3 10 40 21.00 1 1 40.00 26.25 MATERIAL LIST: PV-6 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 QTY.PART PART # DESCRIPTION 17 MODULES 114-350 LONGI SOLAR: LR4-60HPB-350M 17 OPTIMIZERS 130-401 SOLAREDGE P401 POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE) 2 CONNECTORS 240-301 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE) 1 INVERTER 120-503 SOLAREDGE SE5000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 321-030 30A RATED 240VAC NEMA 3R UL LISTED 1 ROOF ATTACHMENT 1 240-401 S-5!: PROTEA 14 RAIL 1 211-100 UNIRAC SM LIGHT RAIL 168 INCH (TOTAL 188 FEET NEEDED) 17 RAIL HARDWARE 1 261-517 BND T-BOLT AND NUT SS 18 MODULE CLAMPS 1 221-101 SM MIDCLAMP PRO DRK 18 MODULE CLAMPS 1 221-202 SM ENDCLAMP PRO W/ END CLAMP 6 SPLICE 1 261-600 BND SPLICE BAR PRO SERIES MILL 18 MLPE MOUNT 1 261-510 MICRO MNT BND TBOLT SS 5 ACCESSORIES 1 211-202 E-BOSS CONDUIT MOUNT COMP KIT 10 ACCESSORIES 1 211-200 E-BOSS RAIL TRAY 4 ACCESSORIES 1 211-206 E-BOSS BRIDGE TRAY 6 ACCESSORIES 1 211-207 E-BOSS BRIDGE CLIPS 28 GROUNDING LUG 1 260-300 BURNDY GROUND WEEB-LUG 29 L-FOOT 1 241-100 UNIRAC L-FOOT SERRATED W/T-BOLT CLEAR (KIT) BREAKER SIZES: 30A PV BREAKER SERVICE LIST: NONE EQUIPMENT & SERVICE LIST GREG ALBRIGHT 1. NEC ARTICLES 690 AND 705 AND FBC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. ARIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS NOTES:M690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY IFC 605.11.3.1(1) & 690.56(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC NEC 690.13(B) INVERTER DC SOLAR PV DC CIRCUIT EVERY 10' ON CONDUIT AND ENCLOSURES SOLAR ELECTRIC PV PANELS 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL !WARNING SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUITS NEC 710.15(C) & 692.9 (C) NEC 690.15 (B) & NEC 690.33(D)(2) DO NOT DISCONNECT UNDER LOAD NEC 705.12(D) & NEC 690.59 !CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D) & NEC 690.59 NEC 705.12(C) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. !WARNING ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 24 INCH 3 480 VAC 42 INCH 12 INCH 1 INCH FLASH HAZARD BOUNDARY CAL/CM^2 FLASH HAZARD AT 18 INCHES SHOCK HAZARD WHEN COVER IS REMOVED LIMITED APPROACH RESTRICTED APPROACH - 500 V CLASS 00 GLOVES PROHIBITED APPROACH - 500 V CLASS 00 GLOVES LOCATION:6789 PICANTE CIRCLE,FORT PIERCE, FL 34951 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 21.00A 240V!WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR NEC 690.54 NEC 705.12(B)(3)(3) NEC 706.15(C) AND NEC 110.16 PMNEC 705.12(D) & NEC 690.59 !WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM !WARNING THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(E) PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES NEC 690.31(O)(2) NEC 690.31(D)(2) NEC 690.13(B) PHOTOVOLTAIC DC DISCONNECT 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 MAXIMUM DC VOLTAGE OF PV SYSTEM ARRAY J/B NEC 690.31(G)(3) & (4) 706.15(C)(4) & 690.13(B) !WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 110.27(C) & OSHA 1910.145(F)(7) !WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3)MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX DC-DC CONVERTER OUTPUT CURRENT V A A 13.5 480 15 PV-7 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 LABELS GREG ALBRIGHT MSP UM AC INV JB MAIN SERVICE PANEL INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX 17 PV MODULE PICANTE CIRCLEAC DISCONNECT UTILITY METER CAUTION: MULTIPLE SOURCES OF POWER LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES 6X8" TYP - NEC 705.10 PV-7A FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 1. NEC ARTICLES 690 AND 705 AND FBC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: SITE PLACARD GREG ALBRIGHT 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 PV-8 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART GREG ALBRIGHT SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET IN CASE OF EMERGENCY NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC NAME: _______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION NAME: _______________________________________________ ADDRESS: ___________________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O PV-9 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 SAFETY PLAN GREG ALBRIGHT JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access x Ladders must be inspected before each use. x Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. x Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. x A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). x Additional notes: Mobile Equipment x Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. x Type(s) of mobile equipment (Type/Make/Model): x Qualified operator(s): Material Handling and Storage x Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection x A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. x First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. x FPCP (name and title): x FPU and LPD (name and title): Electrical Safety x The Electrical Qualified Person (EQP) is required onsite to perform electrical work. x All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. x Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. x EQP (name and tile): Public Protection x The safety of the Client and Public must be maintained at all times. x The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. x Company, Client and Public property shall be protected from falling objects. x Pets (including dogs) shall be secured by their owners prior to work start. x The Client should not leave pets, family members, or others in charge or care of Employees, Contractors, or Temporary Workers. x Crew leader responsible for communication with the client: x Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing x All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. x Crew leader (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): Airborne Contaminants: x Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) x Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. x If yes, list specific tasks and protection in place: Weather and Environment x The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) x The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. x Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. x Forecasted weather maximum temp (degrees f): Heat Related Illness Prevention x Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. x Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. x New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. x Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. x Cool Vests are encouraged for all employees at all times during periods of high heat. x Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? x If offsite replenish is necessary, where will you go to replenish water (location/address): x Who will replenish the drinking water (name): Restroom facilities x Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. x Restroom facilities will be (circle one): Onsite - Offsite x If Offsite, add location name and address: Incident Reporting Procedure x Contact your Site Supervisor Name: Phone: x Contact your Manager Name: Phone: x Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: PV-10 FREEDOM FOREVER INDY 8.00 TEMPLATECONTRACTOR LICENSE: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 DESCRIPTION DATENO. SHEET: REVISIONS JOB NO: F103860 DESIGNED BY: ANTON CLIENT: DONALD ROBINSON 6789 PICANTE CIRCLE, FORT PIERCE, FL 34951 AHJ: ST. LUCIE COUNTY UTILITY: FPL - FLORIDA POWER & LIGHT PHONE: (914) 409-6103 SYSTEM: SYSTEM SIZE (DC): 17 X 350 = 5.950 kW SYSTEM SIZE (AC): 5.000 kW @ 240V MODULES: 17 X LONGI SOLAR: LR4-60HPB-350M OPTIMIZERS: 17 X SOLAREDGE P401 INVERTER: SOLAREDGE SE5000H-USRGM [SI1] DATE: 8/31/2021 SAFETY PLAN GREG ALBRIGHT POWER OPTIMIZERsolaredge.com PV power optimization at the module-level 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK6RODU(GJH LQYHUWHUV 8SWRPRUHHQHUJ\ )OH[LEOHV\VWHPGHVLJQIRUPD[LPXPVSDFH XWLOL]DWLRQ )DVWLQVWDOODWLRQZLWKDVLQJOHEROW 1H[WJHQHUDWLRQPDLQWHQDQFHZLWKPRGXOH OHYHOPRQLWRULQJ 0HHWV1(&UHTXLUHPHQWVIRUDUFIDXOW SURWHFWLRQ $)&, DQG3KRWRYROWDLF5DSLG 6KXWGRZQ6\VWHP 39566 0RGXOHOHYHOYROWDJHVKXWGRZQIRULQVWDOOHU DQGÀUHÀJKWHUVDIHW\ 6XSHULRUHIÀFLHQF\  0LWLJDWHVDOOW\SHVRIPRGXOHPLVPDWFKORVVHV IURPPDQXIDFWXULQJWROHUDQFHWRSDUWLDO VKDGLQJ Power Optimizer For North America 33333 25 YEARWARRANTY Œ6RODU(GJH7HFKQRORJLHV/WG$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV ,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH'61$6XEMHFWWRFKDQJHZLWKRXWQRWLFH  )RUGHWDLOHGᐎULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVᐎULQJBVL]LQJBQDSGI  ,WLVQRWDOORZHGWRPL[33ZLWK333LQRQHᐎULQJ  ,IWKHLQYHUWHUVUDWHG$&SRZHU•PD[LPXPQRPLQDOSRZHUSHUᐎULQJWKHQWKHPD[LPXPSRZHUSHUᐎULQJZLOOEHDEOHWRUHDFKXSWRWKHLQYHUWHUVPD[LPXPLQSXW'&SRZHU5HIHUWRKWWSVZZZVRODUHGJH FRPVLWHVGHIDXOWÀOHVVHSRZHURSWLPL]HUVLQJOHᐎULQJGHVLJQDSSOLFDWLRQQRWHSGI  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV:  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV: Power Optimizer For North America 33333 Optimizer model (typical module compatibility) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96- cell modules) P401 (for high power 60 and 72 cell modules) P485 (for high-voltage modules) P505 (for higher current modules) INPUT 5DWHG,QSXW'&3RZHU      : $EVROXWH0D[LPXP,QSXW9ROWDJH 9RFDWORZHᐎWHPSHUDWXUH     (2)(2)9GF 03372SHUDWLQJ5DQJH      9GF 0D[LPXP6KRUW&LUFXLW&XUUHQW ,VF       $GF 0D[LPXP(੕FLHQF\% :HLJKWHG(੕FLHQF\% 2YHUYROWDJH&DWHJRU\II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 0D[LPXP2XWSXW&XUUHQW  $GF 0D[LPXP2XWSXW9ROWDJH  9GF OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 6DIHW\2XWSXW9ROWDJHSHU3RZHU2SWLPL]HU ” 9GF STANDARD COMPLIANCE 3KRWRYROWDLF5DSLG6KXWGRZQ6\ᐎHP 1(&  1(&  1(&  (0&)&&3DUW&ODVV%,(&,(& 6DIHW\,(& FODVV,,VDIHW\ 8/ 0DWHULDO 8/9895HVLᐎDQW 5R+6 Yes INSTALLATION SPECIFICATIONS 0D[LPXP$OORZHG6\ᐎHP9ROWDJH  9GF &RPSDWLEOHLQYHUWHUV $OO6RODU(GJH6LQJOH3KDVHDQG7KUHH3KDVHLQYHUWHUV 'LPHQVLRQV :[/[+ [[[ [ [[ [[ [[[ [ [[ [[ [[ [[ mm LQ :HLJKW LQFOXGLQJFDEOHV      JUOE ,QSXW&RQQHFWRU 0&  6LQJOHRUGXDO0&   0&  ,QSXW:LUH/HQJWK        PIW 2XWSXW:LUH7\SH&RQQHFWRU 'RXEOH,QVXODWHG0& 2XWSXW:LUH/HQJWK  PIW 2SHUDWLQJ7HPSHUDWXUH5DQJH  WRWR Ü&Ü) 3URWHFWLRQ5DWLQJ ,31(0$3 5HODWLYH+XPLGLW\%  5DWHGSRZHURIWKHPRGXOHDW67&ZLOOQRWH[FHHGWKHRSWLPL]HU´5DWHG,QSXW'&3RZHUµ0RGXOHVZLWKXSWRSRZHUWROHUDQFHDUHDOORZHG  1(&UHTXLUHVPD[LQSXWYROWDJHEHQRWPRUHWKDQ9  )RURWKHUFRQQHFWRUW\SHVSOHDVHFRQWDFW6RODU(GJH  )RUGXDOYHUVLRQIRUSDUDOOHOFRQQHFWLRQRIWZRPRGXOHVXVH310'050,QWKHFDVHRIDQRGGQXPEHURI39PRGXOHVLQRQHᐎULQJLQᐎDOOLQJRQH3GXDOYHUVLRQSRZHURSWLPL]HUFRQQHFWHG WRRQH39PRGXOH:KHQFRQQHFWLQJDVLQJOHPRGXOHVHDOWKHXQXVHGLQSXWFRQQHFWRUVZLWKWKHVXSSOLHGSDLURIVHDOV  )RUDPELHQWWHPSHUDWXUHDERYHƒ&ƒ)SRZHUGHUDWLQJLVDSSOLHG5HIHUWR3RZHU2SWLPL]HUV7HPSHUDWXUH'H5DWLQJ7HFKQLFDO1RWHIRUPRUHGHWDLOV PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid 0LQLPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV  333    336  0D[LPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV    0D[LPXP1RPLQDO3RZHUSHU6WULQJ    ZLWK 6(866(86   (9)  : 3DUDOOHO6WULQJVRI'L੔HUHQW/HQJWKVRU2ULHQWDWLRQV Yes INVERTERSsolaredge.com Optimized installation with HD-Wave technology 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK SRZHURSWLPL]HUV %XLOWLQPRGXOHOHYHOPRQLWRULQJ 2XWGRRUDQGLQGRRULQVWDOODWLRQ 2SWLRQDO5HYHQXHJUDGHGDWD$16,& &ODVV DFFXUDF\ 5HFRUGEUHDNLQJH඼FLHQF\ )L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV ,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLGVKXWGRZQIRU 1(&DQGSHUDUWLFOHDQG ([WUHPHO\VPDOO 8/6$FHUWLÀHGIRU&38&5XOHJULG FRPSOLDQFH Single Phase Inverter with HD-Wave Technology for North America 6(+866(+866(+866(+86 6(+866(+866(+86 12-25 YEARWARRANTY SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9 -9 --9 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16-24- -48.5A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGV Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9-13.5--27Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity 0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 % &(&:HLJKWHG(੕FLHQF\99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional (3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 0D[LPXPᐎULQJV$:* 0D[LPXPᐎULQJV$:* Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 OENJ Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü& Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de-rating information refer to: KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI (5) -40 version P/N: SExxxxH-US000NNU4 SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9 9 9 9 9 9 9 Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9 -9 --9 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, &RXQWU\&RQÀJXUDEOH7KUHVKROGV Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity 0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 % &(&:HLJKWHG(੕FLHQF\99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATI ON SPECIFICATI ONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 0D[LPXPᐎULQJV$:*0D[LPXPᐎULQJV$:* Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 OENJ Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60(4) Ü)Ü&RSWLRQ (5)Ü)Ü& Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG (3) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de-rating information refer to:KWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI (5) -40 version P/N: SExxxxH-US000NNU4 Single Phase Inverter with HD-Wave Technology for North America 6(+866(+866(+866(+86 6(+866(+866(+86 Œ6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OO RWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH pe.eaton.com Eaton general duty non-fusible safety switch DG221URB UPC:782113120232 Dimensions: Height:10.81 IN● Length:6.88 IN● Width:6.38 IN● Weight:6 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. ● Specifications: Type:Non-fusible, single-throw● Amperage Rating:30A● Enclosure:NEMA 3R, Rainproof● Enclosure Material:Painted galvanized steel● Fuse Configuration:Non-fusible● Number Of Poles:Two-pole● Number Of Wires:Two-wire● Product Category:General duty safety switch● Voltage Rating:240V● Supporting documents: Eatons Volume 2-Commercial Distribution● Eaton Specification Sheet - DG221URB● Certifications: UL Listed● Product compliance:No Data ______________________________________________________________________ © 2016 Eaton. All rights reserved. 888-825-3432 | www.S-5.com | • 34% lighter - saves on shipping • Stronger L-Foot™ • Load-tested for engineered application • Corrosion-resistant materials • Adjustable - Fits rib profiles up to 3" • Peel-and-Stick prevents accidental shifting during installation • Fully pre-assembled • 25-year warranty* Features and Benefits NOW AVAILABLE IN ALUMINUM The right way to attach solar PV to trapezoidal roof profiles! ProteaBracket™ ™ProteaBracket™ A versatile bracket for mounting solar PV to trapezoidal roof profiles ProteaBracket™ is now made in aluminum. Still the most versatile trapezoidal metal roof attachment solution on the market, the S-5! ProteaBracket just got better! The bracket features an adjustable attachment base and module attachment options to accommodate different roof profile dimensions and mounting options. Our pre-applied EPDM gasket with peel and stick adhesive makes installation a snap, ensuring accurate and secure placement the first time. With no messy sealants, faster installation, and a weather-proof fit, ProteaBracket offers you the most versatile solar attachment solution available. ProteaBracket* can be used for rail mounting or “direct-attach” with S-5! PVKIT™ *When ProteaBracket is used in conjunction with the S-5! PVKIT, an additional nut is required during installation. *See www.S-5.com for details. S-5!® Warning! Please use this product responsibly! Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, bolt torque, patents, and trademarks, visit the S-5! website at www.S-5.com. Copyright 2019, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 07089. No surface preparation needed. (1) Wipe away excess oil and debris. (2) Peel off adhesive release paper. (3) Align and mount bracket directly onto crown of panel. (4) Secure ProteaBracket through pre-punched holes, using piercing-point S-5! screws.INSTALLATION: Distributed by ProteaBracket™ is the perfect solar attachment solution for most trapezoidal rib, exposed-fastened metal roof profiles! ProteaBracket™ ProteaBracket™ is compatible with common metal roofing materials and comes with a pre-applied EPDM gasket on the base. For design assistance, ask your distributor, or visit www.S-5.com for the independent lab test data that can be used for load-critical designs and applications. Also, please visit our website for more information including metallurgical compatibilities and specifications. Multiple Attachment Options: Side Mount Rail Bottom Mount Rail w/ S-5! PVKIT™ (rail-less) S-5!® holding strength is unmatched in the industry. ProteaBracket™ and the S-5! PVKIT™ 2.0 mounted on a trapezoidal roof profile ProteaBracket™ is still available in stainless steel. Note: All four pre-punched holes must be used to achieve tested strength. Fasteners are provided. ProteaBracket fits profiles up to 3 inches 2.95" 4.03" SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICEWith Superior Aesthetics CONCEALED UNIVERSAL CLAMPS W WITH UNIVERSAL MIDCLAMPIWITHTHUUNINEVESRSRSALALALMMIDICLCLAMP 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the ƛQDQFLDOVWUHQJWKWREDFNRXUSURGXFWVDQGUHGXFH\RXUULVN Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year OLPLWHGSURGXFWZDUUDQW\DQGD\HDUOLPLWHGƛQLVKZDUUDQW\ TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly VLPSOLƛHV\RXUSHUPLWWLQJDQGSURMHFWSODQQLQJSURFHVV CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO FHUWLƛFDWLRQVIRUDQG2+6$6 18001:2007, which means we deliver the highest standards IRUƛWIRUPDQGIXQFWLRQ7KHVHFHUWLƛFDWLRQVGHPRQVWUDWH RXUH[FHOOHQFHDQGFRPPLWPHQWWRƛUVWFODVVEXVLQHVVSUDFWLFHV UL2703 BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONLISTEDSOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702PUB2018AUG31 – PRINTED UPDATE DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 Project: 80082031 Date Issued: 2021-06-02 Issued To: Unirac 1411 Broadway NE Albuquerque, New Mexico, 87102 United States Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems CLASS - C531382 - POWER SUPPLIES - PHOTOVOLTAICS-PV Racking and clamping systems - Certified to US Standards Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA - Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. Solarmount Certificate: 70131735 Project: 80082031 Master Contract: 266909 Date Issued: 2021-06-02 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, 10, 19, 22 or 25 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. UL 2703 Mechanical Load ratings: Downward Design Load (lb/ft²) 113.5 Upward Design Load (lb/ft²) 50.7 Down-Slope Load (lb/ft²) 16.13 Test Loads: Downward Load (lb/ft²) 170.20 Upward Load (lb/ft²) 76.07 Down-Slope Load (lb/ft²) 24.2 Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPENDIX HTechnicalData SheetsUnitsinplfin²SECTION MODULUS (X-AXIS)in³SECTION MODULUS (Y-AXIS)in³MOMENT OF INERTIA (X-AXIS) in4MOMENT OF INERTIA (Y-AXIS)in4RADIUS OF GYRATION (X-AXIS)inRADIUS OF GYRATION (Y-AXIS)in0.564 0.865 1.170.15 0.363 0.8980.067 0.113 0.2211.271CROSS SECTION AREA0.409 0.625 1.059BEAM HEIGHT1.70 2.57 3.00APPROX WEIGHT0.491 0.7280.254 0.269 0.5020.13 0.467 1.450.026 0.045 0.267PropertiesSOLARMOUNT LightSOLARMOUNT Rail Profile 2SOLARMOUNT HDPAGE H3TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458 January 20, 2021 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U-builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. 2020 Florida Building Code, by Florida Building Commission 2. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-16 3. 2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. 2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Ground Snow Load = 0 - 100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Attachment Spacing: Per U-builder Engineering report. Cantilever: Maximum cantilever length is L/3, where “L” is the span noted in the U-Builder online tool. Clearance: 2” to 10” clear from top of roof to top of PV panel. Tolerance(s): 1.0” tolerance for any specified dimension in this report is allowed for installation. Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661T 916.961.3960 F 916.961.3965 W www.pzse.comExperience | Integrity | Empowerment Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor װE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 1478 Stone Point Drive, Suite 190, Roseville, CA 95661T 916.961.3960 F 916.961.3965 W www.pzse.comExperience | Integrity | EmpowermentEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 73522THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 01/20/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.01/20/2021DIGITAL SIGNATURE