Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL MODIFIED BITUMEN ROOF SYTEM
9/2/2021 Florida Building Code Online ` N � A - Professional Regulation BCIS Home I Lag 1. I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I search I bProduct Approval ro USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL1654-R28 Application Type Revision Code Version 2020 Application Status Approved Comments Archived I Product Manufacturer POLYGLASS USA Address/ Phone/ Emal1 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866)802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Small 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (1 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/07/2022 Validated By Jahn W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL1654 R28 COI 2021 01 COI NIEMINEN.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D4601 2012 ASTM D4897 2009 ASTM D6162 2015 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 https:/IfloridabLii[ding.org/pr/pr_app_dii.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPy2pw6pKxAhnrwsBnyiPJI3EK2tvUzRrg%3d%3d 1/2 9/2/2021 Florida Building Code Online FM 4470 2016 FM 4474 2011 UL 1897 2012 Equivalence of Product Standards CertiFled By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/09/2021 Date Validated 06/14/2021 Date Pending FBC Approval O6/18/2021 Date Approved 08/10/2021 Summa of Products FL # Modelr Number or Name Description 1654.1 Polyglass Modified Bitumen Roof Systems for use In FBC non-HVHZ jurlsdictlons. Llmlts of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-622.6 Other: 1.) The design pressure in this application relates to one particular assembly over concrete deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 6 for other Limits of Use. 3.) Refer to FL16717 for HVHZ jurlsdictlons. SBS and APP modlFled bitumen roof systems Installation Instructions FL1654 R28 II 2021 06 09 FINAL Al ER PG MODBIT FL1664- HZ� VeriFled By: Robert Nleminen PE-69166 Created by Independent Third Party: Yes Evaluation Reports FL1654 R28 AE 2021 06 09 FINAL ER PG MODBIT FL1654- R28.pdf Created by Independent Third Party: Yes Back Nezt ContaR Us :: 2601 Blair Scone Roatl Tallahassee F132399 Phone: 850-98]-1824 The State of Florida Is an AA/EEO employer. �RYLah[ 200]-2013 State of Florida.:: Privacy Statement :: AccesslbiliN Statement :: Refund Statement Untler Florida law, email adtlresses are public records. If you tlo not want your a -mall adtlress releasetl In response to apublic-records request, do not sentl elxtronic mall [o Nls entity. Instead, contact the office by phone or by [ratll[lonal mall. If you have any quesnons, please contact 850,48].1398. •Pursuant to Section 485.275(Il, Florltla Statutes, effective Oc[aber 1, 2012, Iirensees licensed antler Chapter 455, F.S. must provide the Department with an email adtlress if they have one. lbe emalls provltletl may be used for official communication with [he licensee. However email adtlresses are public record. If you do not wish to supply a personal address, please provide the Department with an email adtlress which can be matle available to the public. To determine if you are a licensee antler Chapter 455, F.S., please click here . Product Approval Accepts: ®®� k�Y Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?pamm=wGEVXQwtDgvgqu2w%26nFgIlPv2pw6pKxAhnrwsBnyiP113EK2tvUzRrg%3d�3d 2/2 NEMO l etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION• Polyglass USA, Inc. Evaluation Report P9290.02.08-1125 1111 West Newport Center Drive FL1654-R27 Deerfield Beach, FL 33442 Date of Issuance:02/11/2008 (954) 2334330 Revision 25: 09/30/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Cade. The product described herein has been evaluated for compliance with the 7eh Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 94-page Appendix. Prepared by: 0111noo, —_ ��P•.••G4rtg.. a,'�y� . Robert J.M. Nieminen, P.E. ;*••Feq��_, Thefacsimile seal appearing was authorized hyRobert ,.,FSSioui�a• Florida Registration No. 59166, Florida DCA ANE1983 .;!yr,,,,,,,,,,,�"` Nieminen, P.E. on 09/30/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1, NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©20181 NEMO ETC, LLC 4NEMOI etc. ROOFING YSIEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Prooertv Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2012 1504.E Accelerated weathering ASTM G155 2013 1504.7 Impact resistance FM 4470, Section 4.6 2016 1507.10.2 Material standard ASTM D4601 2012 1507.10.2 Material standard ASTM D4897 2009 1507.11.2 Material standard ASTM D6162 2015 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 1507.11.2 Material standard ASTM D6509 2015 Entitv Exam Reference Date Entitv Exam Reference Date ERD (TSTfi009) Physicals P10490.10.08-2 10/30/2008 FM (TST1867) FM 4470 3006115 OS/02/2001 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 FM (TST1867) FM 4470 3012321 07/29/2002 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 FM (TST1867) FM 4470 3014692 08/05/2003 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 FM (TST1867) FM 4470 30147S3 08/27/2003 ERD (TST6049) FM 4470/4474 P30550,12.09 12/02/2009 FM (TST1867) FM 4470 3007170 01/13/2004 ERD(TST6049) Physicals P33960.12.10 12/30/2010 FM (TST1867) FM 4470 3019317 06/30/2004 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM (TST1867) FM 4470 3020703 07/30/2004 ERD (TST6049) Physicals P37590.03.13-3A 03/06/2013 FM (TST1867) FM 4470/4474 3018332 01/31/2006 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM (TST1867) FM 4470/4474 3023368 03/20/2006 ERD (TST6049) Physicals P37590.03.13-1-R1 06/26/2013 FM (TST1867) FM 4470/4474 3024594 05/23/2006 ERD (TST6049) Physicals P37590.03.13-2-R1 07/01/2013 FM (TST1867) FM 4470/4474 3023458 07/18/2006 ERD (TST6049) Physicals P37590.07.13-2 07/01/2013 FM (TST1867) FM 4470/4474 3030668 09/12/2007 ERD (TST6049) Physicals P37590.03.13-5-R1 07/01/2013 FM (TST1867) FM 4470/4474 3032172 06/12/2009 ERD (TST6049) Physicals P37S90.07.13-1 07/02/2013 FM (TST1867) FM 4470/4474 3049631 04/21/2014 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM (TST1867) FM 4470/4474 3057029 02/02/2017 ERD(TSr6049) Physicals P45940.09.13 09/04/2013 NEMO (TST6049) Criticality 4S-PLYG-18-001.06.19 06/23/2018 ERD(TST6049) Physicals P44370.10.13 10/04/2013 NEMO (TST6049) FM 4474 4-PLYG-I8-003.08.18 08/21/2018 ERD(TST6049) Physicals PMS20.09.14-2 09/11/2014 ROAD (TST6049) Criticality 4SPLYG-18-001AGAS 10/03/2018 ERD (TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 NEMO (TST6049) ASTM D4897 4S-PLYG-18-002.11.18-2 11/16/2018 ERD (TST6049) Physicals P45440SC.03.15-1 03/31/2015 NEMO (TST6049) ASTM D6164 4S-PLYG-18-002.11.38-3 11/28/2018 ERD (TST6049) Physicals SCS170.05.15 05/08/2015 NEMO (TST6049) FM 4474 4L-PLYG-18-003.11.18 11/28/2018 ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015 NEMO (TST6049) FM 4474 41--PLYG-18-003,01.19 01/11/2019 ERD(TST6049) Physicals SC5170.12.15 12/29/2015 NEMO (TST6049) .ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019 ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO (TST6049) ASTM D6162 4S-PLYG-18-002.01.19-8 01/25/2019 ERD (TST6049) FM 4470/4474 PLYG.SC8905.05.16-1 05/17/2016 NEMO (TST6049) FM 4474 4L-PLYG-1"03.04.19-A 04/08/2019 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO (TST6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019 ERD (TST6049) FM 4470/4474 PLYG-SC10815.07.16R1 09/23/2016 ROAD (TST6049) ASTM D6222 45-PLYG-18-002.05.19-D 05/20/2019 ERD(TST6049) UL1897 PLYG-SC12025.10.16 10/12/2016 NEMO (TST6049) ASTM D6163 4S-PLYG-18-002.05.19-111 05/20/2019 ERD(TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 NEMO(TST6049) ASTM D6164 45-PLYGA"02.05.19-N 05/31/2019 ERD(TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 NEMO (TST6049) Criticality 4S-PLYG-18-001.06.19.A 07/17/2019 ERD(TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 NEMO (TST6049) ASTM D6164 4S-PLYG-18-002.09.19-I 09/06/2019 ERD(TST11294) FM 4470/4474 PLYG-MI3945-05.17-1 05/30/2017 NEMO (TST6049) ASTM D6164 45-PLYG-184)02.09.19-1 09/06/2019 ERD(TST11294) FM 4470/4474 PLYG-Gn13945.05,17-3 05/30/2017 NEMO (TST6049) FM 4474 4a-PLYG-20-LSWUS-01.A 08/28/2020 ERD(TST6049) FM 4470/4474 PLYG-SC13945.05.17 05/30/2017 PRI(TST5878) Physicals PUSA-062-02-01 12/04/2007 ERD(TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/11/2017 PRI(TST5878) Physicals PUSA-061-02-02 01/28/2008 FM(TST1867) FM 4470 2W7A7.AM 08/04/1994 PRI(TST5878) Physicals PUSA-064-02-02 02/27/2008 FM (TST1867) FM 4470 OD3A3.AM 04/04/1997 PRI (TST5878) Physicals PUSA-062-02-02 12/04/2008 FM (TST1867) FM 4470 2DOA0.AM 12/23/1998 PRI (TST5878) TA5114 PUSA-188-02-01 02/08/2017 NEMO ETC, UDC Evaluation Report 139290.02.08-R25 Cert�cate fAuthorizati0n g32455 7T"EDRION (2020)FBC NON-HVHZ EVALUATION FL3654-1127 Polyglass Modified Bitumen Roof Systems Revision 25: 09/30/2020 Page 2 of 5 NNEMO I etc. Entity Exam Reference Date Entity Exam Reference Date FM (TST1867) FM 4470 205A9.AM 06/22/1999 PHI (TST5878) TAS 114 7USA-188-02-02 02/08/2017 FM (TST1867) FM 4470 3006646 01/04/2000 PHI (TST5878) TAS 114 PUSA-188-02-03 02/08/2017 FM (TST1867) FM 4470 3001334 01/25/2000 PHI (TST5878) TAS 114 PUSA-202-02-01 05/17/2017 FM (TST1867) FM 4470 3001334 02/15/2000 PHI (TST5878) TAS 114 PUSA-202-02-02 05/17/2017 FM (TST1867) FM 4470 3000857 01/12/2000 M-D (CER1592) HVHZ Various NOAs Various FM (TST1867) FM 4470 3004091 01/12/2000 M-D (CER1592) Prop. for Rev. 10-0823 10/12/2010 UL (QUA9625) Quality Control Service Confirm 09/13/2018 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. TABLE S: ROLL -GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS Type Product Material Standard Plant(s) Reference Type Grade Polyglass G2 Base ASTM D4601 II N/A AL Polyflex SA Base ASTM D4601 II N/A FL Base Sheets Elastobase SA ASTM D4601 II N/A PA Elastovent ASTM D4897 N/A N/A PA Polyglass Base ASTM D6509 N/A N/A FL Polybond ASTM D6222 I S FL APP, Smooth -Surface Polyflex ASTM D6222 I S FL Membranes Polykool ASTM D6222 I S FL Polybond G ASTM D6222 I G FL Polyflex G ASTM D6222 I G FL Polyflex G FR ASTM D6222 I G FL Polyfresko G ASTM D6222 I G NV APP, Granule -Surface Polyfresko G FR ASTM D6222 I G NV Membranes Polyflex SA P ASTM D6222 I G FL, TX Polyflex SA P FR ASTM D6222 I G TX Polyfresko G SA ASTM D6222 I G NV Polyfresko G SA FR ASTM D6222 I G NV Elastoshield HT ASTM D6162 III S FL Elastobase ASTM D6163 I S FL Elastoflex V ASTM D6163 I S FL Elastoflex SA V ASTM D6163 I S FL, PA, TX Elastoflex SA V FR ASTM D6163 I S FL, PA, TX SBS, Smooth -Surface Elastoflex SA V Plus ASTM D6163 I S FL, TX Membranes Elastoflex SA V Plus FR ASTM D6163 I S FL, TX Elastobase P ASTM D6164 I S FL, TX Elastoflex SA Base HD ASTM D6164 I S PA, TX Elastoflex S6 ASTM D6164 I S FL Elastoflex S6 HP ASTM D6164 II S NV Polyreflect ASTM D6164 I S FL Elastoshield HT G ASTM D6162 III G FL Elastoshield HT G FR ASTM D6162 III G FL Elastoflex V G ASTM D6163 I G FL, PA Elastoflex V G FR ASTM D6163 I G FL, PA SBS, Granule Surface Elastoflex 56 G ASTM D6164 I G FL, PA Membranes Elastoflex S6 G FR ASTM D6164 I G FL Elastoshield TS G ASTM D6164 I G FL, TX Elastoshield TS G FR ASTM D6164 I G FL, TX Elastoflex SA P ASTM D6164 I G FL, TX Elastoflex SA P FR ASTM D6164 I G FL, TX NEMO ETC, LLC Evaluation Report 139290.02.08-1125 CertfJ'cate ojAuthorization M32455 7T"EDITION (2020)FBC NON-HVHZ EVALUATION FL3654-R27 Polyglass Modified Bitumen Roof Systems Revision 25: 09/30/2020 Page 3 of 5 ON ERA oIetc. 5.1 This is a Building Code Evaluation, Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction, 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low -slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105, 5.6.2 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA- 1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. =Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137, Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. NEMO ETC, LLC Evaluation Report P9290.O2.OB-R25 [enJrate ofAurhorization N32455 7T"EDRION 12020J fBC NON-HVHZ EVALUATION FL3654-R27 Polyglass Modified Bitumen Roof Systems Revision 25: 09/30/2020 Page 4 of 5 �4NEMO I etc. Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL, LLC— QUA9625: (414) 245-6409, karen.buchmann@ul.com -THE 94-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Repor[ P9290.02.08-R25 Certfcate oJAuthorization g32455 7T"EDRION (2020) FBC NON-HVHZ EVALUATION FL3654-R27 Polyglass Modified Bitumen Roof Systems Revision 25: 09/30/2020 Page 5 of 5