FL #
FL2569-R22
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived I I
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@soprema.ca
Authorized Signature Marc -Etienne Mathieu
memathleu@soprema,ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean-Francols Cote, Ph.D,
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema,ca
Category
Roofing
Subcategory
Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
I i Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
I I Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R22 CO) 2021 01 COI
NIEMINEN.pa
Referenced Standard and Year (of Standard) 5liandard
Year
ASTM D1970
2015
ASTM D4601
2012
ASTM D4798
2011
FM 4474
2011
FRSA/TRI Sixth Edition
2018
TAS 103
2020
UL1897
2015
h ttps:llfloriclabu i Iding.orglpllln•_npp_dtl,nspx?parnm=wG EVXQwtDgsKQF6nck8108Erx I Ud3xY1 i7ntnGvvoArggkU4EylLattg%3doload 1/2
7/2I2021
FloridR Auilding Codc Onlinc
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2021
Date Validated O4/19/2021
Date Pending FBC Approval 04/26/2021
Date Approved 06/OB/2021
Summary of Productc
1�
FL #
Model, Number or Nama
Description
2569.1
Soprema Roof Underlayments for
Self adhering roof underlayments
use In FBC HVHZ )urlsdlctlons
Llmlts of Use
Installation Instructions
Approved Por use In HVHZ: Yes
Approved for use outside HVHZ: No
FL2569 R22 I[ 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
R22•RQf
Impact Resistant: N/A
VerlNed ey: Robert Nleminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
other: Refer to ER Section 5 for Llmlts of Use.
Evaluation Reports
FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
R22•Rq[
Created by Independent Third Party: Yes
2569.2
Soprema Roof Underlayments for
Self adhering roof underlayments
use In FBC non-HVHZ )urlsdlctlons
Llmlts of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON -
HVHZ FL2569-R22.pQ(
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verined By: Robert Nleminen, P.E, PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1,) Refer to ER Section 5 for Llmlts of Use. 2.)
Evaluation Reports
The design pressure noted herein pertains to
FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA NON-
underlayment systems used beneath adhesive -set the
systems. Refer to ER Section 5.8.3 for details.
HVHZ FL2569-R22.pQ[
Created by Independent Third Party: Yes
OaAr Next
Contact Us ;: 2fi01 elalr Stone Road Tallahassee F132399 Phone: a50-Aa]-1924
The State of Florltla Is an AA/EEO employer. SQRY.deht Z00]-201351ate of Florida.:: Pdvacv Statement ;: c sslbi I V Statement ;: Reluntl Statement
Under Florltla law, email atltlresses are public retards. It you tlo not wan[youf a -mall address releasetl In response to a public-recartls request, tlo not send elechonlr
mall to ibis entity. insteatl, contact the ofRce by phone or by Uaditlonal mall. If you have any Questions, please contact 950.497.1395. 'Pursuant to Section 455.275(1),
Florida statutes, eMeUlva Oc[eber 1, 2012, licensees licensed under Chapter 455, F.S, must prpvltle the Department WIN an email atltlress If they have one. The emails
provided may be usetl for oHirlal cammunlcadon Wlth the Ilrensee. However email addresses are public remrtl. if you do not Wlsh to supply a personal address, please
provide the Department with an email etltlress which can be made available to the public. To determine If you are a Ilrensee antler Chap[ar 455, F.S., please click b_e f_.
Protluct Approval pccepLs:
®®� ��
• a
i'i Ilrll\,,\II Ilt ll�
blips://floridnbuUding.orglpr/pr_Rpp_tillsspx7pRmm=wG6VXQtvIDgsKQF6nckD 108&rxlUd3xYIr7RmGvvoArggkU4EyIL,nlg%3d%3d 2l2
MEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONO•
Sopremar Inc. Evaluation Report S18010.06.09-R20
1640 rue Haggerty FL2569-R22 (NON-HVHZ)
Drummondvllle, Qu6bec J2C 5P8 Canada Date of Issuance: 06/15/2009
(819)478-2400 Revision 20:04/10/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING:
Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" maybe
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robertinen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
b s 4a•" is
�D,���,... a `,;• The Facsimile seal appearing was authorized by Robert
y
!, giN'T�++E'?, Nieminen, P.E, on 04/19/2021. This does not serve as
'.^k�•••"nm"`, an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it Intend to acquire or will It acquire, a financial Interest In any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nleminen, P.E, does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for
which the evaluation reports are being Issued,
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved In the approval process of the
product.
S. This Is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
®2019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
C
4.1
4.2
4NEMOletc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 71h Edition (2020) Florida Building Code through testing In accordance with the
following Standards. Compliance is subject to the Installation Requirements and Llmitatlons / Conditions of Use
set forth herein.
Section
Pro ert
Standard
Year
1504.3A
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1, 1507.2.4,1507.2.9.2
Material standard
ASTM D1970
2015
/ 11905.1.1, 11905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
TAS 110
Accelerated Weathering
ASTM D4798
2011
EntltV
PRODUCT DESCRIPTION:
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778,07,05
07/15/200S
ERD (TST6049)
FRSA/TRI 04-12 (MS)
543530,02.14-1-111
02/21/2014
ERD (TST6049)
ASTM D1970 (QC)
S44870.04,14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
544870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S4054010.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02,15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05,17-RI
06/07/2017
NEMO (TST6049)
ASTM D1970/TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC48-003.08.18
08/27/2018
NEMO (TST6049)
Tile Slippage
4S-SOPC-18-002.09.18
09/21/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW49-SSLAP-01,A.112
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4J-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4J-SOPC-20-SSUDL-01.A
01/07/2021
NEMO (TST6049)
ASTM D1970 (MS)
4J-SOPC-2I-SSUDL-01.A
04/19/2021
PRI(TST5878)
ASTM D1970 (MS)
SOP-064-02.01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No, R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
Material
Product
Plant(s)
Description
Standard
LASTOBOND TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
Tri-BUilt S/A HTTU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
Underlayment
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
NEMO ETC, LLC Evaluation Report 518010.06,09-R20
Certncate oJAuthorization N32455 Ira EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-1122 (NON-HVH2)
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 2 of 8
4.3
4.4
4.5
4.6
4.7
4,8
4.9
4.10
4.11
4.12
4.13
4,14
4.15
4.16
4.17
Material
Product
Plant(s)
Description
Standard
LASTOBOND Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 Inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
LASTOBOND Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available In
two widths; 36 and 45 Inch
LASTOBOND Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
EnvlroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
LASTOBOND Smooth
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrlmeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand -RSA
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, send -
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
PrlmeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report S18010.06.09-R20
CertlJlcate oJAufhorl:orlon ll32455 7'"EDITION (2020)FOC NON-HVHZ EVALUATION FL2569•ft22 (NON•HVHZ)
Soprelna Raof Underlayments Revision 20: 04/19/2021
Page 3 of 8
5.2
5.3
oI Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miaml-
Dade Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be In
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction,
5.4 This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic Insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOf COVER OPTIONS
FBCSectipn:
1507.1
1507.3
1507.4 a 1507.5
1507.7
150A8 & 1507.9
Clay and Concrete Tile
Metal
Slate or
Asphalt
Wood Shakes or
Underlayment
shingles
Mechanical
Adhesive-
Panels
Shingles
g
SShinglles
Shingles
Attach
Set
Shingles
LASTOBOND TU HT, Tri-Built S/A HT TU
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Bolnt strips, 1507.1.1.3/
Underlayment
Y
See 5.6.1
11905.1.1.3)
LASTOBOND Shield, Pro HT-N, RESISTO
Yes
No
No
Yes
Yes
Yes
Yes
(Jolntstrlps, 3507.1.1.3/
SA SMOOTH PLY 40
R905.1.1.9)
Yes
LASTOBOND shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
(Joint strips, 1507.1.1.3/
R905.1.1.3)
Yes
Envlro5hield
Yes
No
No
Yes
Yes
Yes
(Joint strips, 1507.1.t.3/
R905.1.1.9)
LASTOBOND ECO, RESISTO LB12360 TRI-
BUILT Sand-R SA Shingle Underlayment,
Yes
Grip -Rite Eave & Valley Protector,
Yes
No
No
No
No
Yes
0016tetrlps,1507.1.1.3/
TopShleld ICE & WATER DEFENDER,
R905.1.1.3)
RESISTO LB1244
LASTOBOND Smooth Seal HT, Tri-Built
Yes '
Smooth HTS/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
(Jomtadps,1s07,1.1.3/
Smooth Seal HT
R905.1.1.3)
5.6.1 Adhesive -set the is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE 1A; ALLOWABLE TILE ADHESIVE / UNDERIAYMENT COMBINATIONS
Underlayment
Adhesive
Florida Product Approval
LASTOBOND TU HT, Tri-Bullt S/A
HTTU Underlayment
Dupont "rile Bond'"' Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polyset" AH-160"
FL6332
1 Refer to T/le Manufactures orAdheslve Manufacturer's Florida Produc[Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 518030.06.09-R20
CertPcate of Authorization g32455 77N EDITION (2020) FBC NON-HVHZ EVALUATION FL2569•R22 (NON-HVH2)
Soprema Roof Underlayments Revision 20: 09/19/2021
Page 4 of 8
Nenno I etc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type
Primer
Material(s)
LASTOBOND Shield, LASTOBOND Pro HT-
(Optional) ASTM
N, RESISTO SA SMOOTH PLY 40,
Deck /
D41, Elastocol Stick,
Plywood, OSB or Southern Yellow
LASTOBOND Shield HT, LASTOBOND Pro
sheathing
Elastocol Stick Zero
Pine (SYP)
ASTM D41
structural concrete
HT-S, EnvlroShield, LASTOBOND TU HT,
Tri-Built S/A HT TU Underlayment,
(Optional) Elastocol
Dens Deck Prime or SECUROCK
LASTOBOND ECO, RESISTO LB1236, TRI-
self-
Insulation
Stick Zero
Gypsum -Fiber Roof Board
BUILT Sand -RSA Shingle Underlayment,
Grip -Rite Eave & Valley Protector,
adhering
TopShleld ICE & WATER DEFENDER,
RESISTO L81244, LASTOBOND Smooth
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or
Seal HT, Tri-Built Smooth HT S/A
Stick Zero
Modified Sopra-G
Underlayment or Grip -Rite Smooth Seal
HT
LASTOBOND TU HT, Tri-Built S/A HTTU
Underlayment, RESISTO LB1236,TRI-
Existing sand -surfaced, glass -fiber
BUILT Sand-RSAShingle Underlayment,
self-
Existing
O EXTERIOR
surfaced, mineral -surfaced or film -
Grip -Rite Eave & Valley Protector or
adhering
substrate
PRIMER
PRIME
surfaced roof underlayment
TopShleld ICE & WATER DEFENDER
"Final acceptance of any existing substrate In a reroof (tear•offJ Installation Is at the discretion of the Installer and the Authority
Having Jurisdiction. Should a question arise as to the sultoblllty of an existing substrate to receive LASTOBOND TU HT, Trl-Built S/A HT
TU Underlayment RESISTO LB1236, TRI-BUILTSand-RSA Shingle Underlayment Grip -Rite Eave & Valley Protector or TopShleld ICE &
WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for Installation within 24 hours.
S.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations;
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets -not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation
Instructions, but —for mechanically attached base sheets -not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in The Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
NEMO ETC, LLC Evaluation Report 518010.06.09-R20
OutIlcate of Authorization N32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ)
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 5 of 8
ONEMOletc.
#1 Maximum Design Pressure =-45.0 psi:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, TrkBuilt S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x 1Ya" ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-inch o.c..
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x 1YH" ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c.,
#3
Maximum
Design Pressure=-120.0 psf:
Deck: Min. 15/32-Inch APA-rated COX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back-nalled within the
selvedge -edge side laps using 12 ga. x 1W ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c..
#4
Maximum Design Pressure = 450.0 psf:
Deck: Min. 15/32Anch APA-rated BCX plywood (may be Installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, TrkBuilt S/A HT TU Underlayment, self -adhered and back-nalled within the
selvedge -edge side laps using 12 ga. x 1Y4" ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c..
#5
All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2
Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined In accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined In accordancewith FBC 1609 or FBC Residential Chapter3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth In Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6
Maximum Design Pressure =-60.0 psf:
Deck: Min.19/32-Inch plywood to meet project requlrementstosatisfaction ofAuthority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
Inch o.c. at the 4-Inch laps and &Inch o.c. in three (3), equally spaced rows In the center of the sheet.
Underlayment: LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, self -adhered and back -nailed within the
selvedge -edge side laps using 12 ga. x 19" ring shank nails through 32 ga., 1-5/8" diameter tin caps
spaced 12-Inch o.c.
5.8.4
For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be In accordance with the manufacturer's installation Instructions and attachment of the
Insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
NEMO ETC,
LLC Evaluation Report S18010.06.09-1120
CertProte ofAuthorlmtton N32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-1122 (NON-HVHZ)
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 6 of 8
Nemo I etc.
5.9 Exposure LlmiLations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
Installation Type
Exposure (days)
LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector, TopShleld ICE & WATER DEFENDER or RESISTO
Mechanically attached
30
L01244
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 400
LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnvlroShleld, LASTOBOND Smooth
Mechanically attached
90
Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT
Mechanically attached or
LASTOBOND TUHTorTrl-BuiltS/A HTTUUnderlayment
adhesive -set tile roof
180
system
5.10 The SIIDDaI:e Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECKTILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max.10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Double -tile stacking method, as shown below 6:12
LASTOBOND TU HT, Tri-
Built S/A HT TU
Underlayment
Lugged
-
�-
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published Installation Instructions
subJect to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO 1.81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShleld ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate In a reroof (tear -off) Installation is at the discretion of the Installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO 1.131236, TRI-BUILT Sand-R SA Shingle Underlayment, Grlp-Rite Eave & Valley Protector or TopShleld ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
NEMO ETC, LLC Evaluation Report S38010.06.09-1120
Certificate ofAuthorizatlon N31455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R22 (NON-HVHZ)
Soprema Roof Underlayments Revision 20: 04/19/2021
Page 7 of 8
NI=_mo I etc.
6.3 LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment, LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA
SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShleld, LASTOBOND Eco, LASTOBOND
Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite Smooth Seal HT, RESISTO LB1236, TRI-BUILT
Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShleld ICE & WATER DEFENDER or
RESISTO LB1244:
6.3.1 Non-TIIeApplicatlons:
Shall be Installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) In
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be Installed, and the manufacturer's installation instructions.
When Installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or 11905.1.1.
6.3.2 Tile Applications:
Limited
to LASTOBOND
TU HT or Tri-Built S/A HT TU
Underlayment.
Shall be Installed in compliance with the requirements for Self -Adhered Membrane set forth In FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
Instructions,
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
As required by the Building Offlclal or Authority Having Jurisdiction to
product.
Installation of this
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC—QUA962$; (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT-
NEMO E7C, LLC Evaluation Report 618010.06.09•R20
Certificate oJnuthodrntlon /H2a55 7TM EDITION (20Z0) FBC NON•HVHZ EVALUATION FL2569•R22 (NON•HVHZ)
Sopreme Roof Underlayments Revision 20: 04/19/2021
Page 8 of 8