Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of .Business and Professional Regulation - Residential Performance Method RECEIVED Project Name: LOT 5 and 6 Notlem Drive Fort Pierce :. Builder_ Name: Habitat for Humanity JUL• 1 Street: LOT 5-6 Notlem Drive Permit Office: �O�j City, State, Zip: Fort Pierce , FL , Permit Number: St, L•tt0{ri County. Owner. Joseph Gianna Jurisdiction: Permitting Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. ' New construction or ekisting New (From Plans) 9. Wall Types (1248.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a..Concrete Block - Int Insul, :Exterior R=5.0 1080.00 ft2 b: Concrete Block- Int Insul; Adjacent R=5.0 .168.00 ft2 3. Number of units, if multiple family 1. c. N/A. R=_ . ft2 4. Number of Bedrooms 3 d. N/A. R= ft2 5: Is this a worst case? No 10. Ceiling Types (1292.0 sqft.) Insulation Area a. UnderAttic (Vented) .. R=30.0 1292.00 ft2 6. Conditioned floor area above grade (ft2) 1292 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A ... R= ft2 . 11. Ducts R •ft2 7. Windows(85.1 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage .6 _ 258 a. U-Factor: Dbl; U=0.60 85:14 ft2 SHGC: SHGC=0:24 b. U-Factor: N/A ft2 12..Cocling systems:: kBtu/hr Efficiency SHGC: a. Central Unit 27.6 SEER:16.00 c. U-Factor: N/A ft2: SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 - a. Electric Strip Heat 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000, ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1291.0 sgft.) Insulation Area EFi 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1291.00 ft2 b. Conservation features b. N/A R= ft2.. None . c. N/A R= ft2 . 15. Credits • .. - CV . Total Proposed Modified Loads: 44.01 Glass/Floor Area: 0.066 �+C PASS SS Total Baseline Loads:..: 44.49 I hereby certify that the plans and specifications covered'by Review of,the plans and 4ZHE SSA? this calculation are in compliance with the Florida Energy' Code. specifications covered by this indicates 1�_ 0,�, calculation compliance nGGa�ZCUZ with the Florida Energy Code. mr�-. �„�O I! PREPARED. BY: d%L . DATE: February 4, 2021 Before construction is completed this building willbe inspected for compliance with Section 553.908 hereby certify that this buil ing, as designed, is in compliance Florida Statutes. with the Florida Energ C COD WEB OWNER/AGENT: BUILDING OFFICIAL:. . DATE: �- DATE: - Compliance requires certification by the air handler'unit manufacturer that the air handler enclosure,qualifles'as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage -test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LOT 5 and 6 Notlem Drive For Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1292 Lot # Owner Name: Joseph Gianna Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: LOT 5-6 Notlem Drive Permit Office: Cross Ventilation: Yes County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer, Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1292 10336 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 131 1048 No 1 1 1 Yes Yes Yes 2 KITCHEN 116 928 Yes 0 1 Yes Yes Yes 3 pnty . 11 88 No 0 1 No Yes Yes 4 BATH 50 396 No 0 1 No Yes Yes 5 Laundry 72 572 No 0 1 Yes Yes Yes 6 BATH 1 66 528 No 0 1 Yes Yes Yes 7 Master Bed 162 .1296 No 2 1 1 Yes Yes Yes 8 M CL 25 196 No 0 1 Yes Yes Yes 9 BEDROOM 2 144 1152 No 1 1 1 Yes Yes Yes 10 CL 3 15 120 No 0 1 No Yes Yes 11 CL 2 16 130 No 0 1 Yes Yes Yes 12 Hall 61 488 No 0 1 No Yes Yes 13 LIVING ROOM 423 3384 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 3 10.5 ft 131.3 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulatio KITCHEN 21.5 ft 115.5 ft2 1 0 0 3 Slab -On -Grade Edge Insulatio pnty 1 ft 11 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio BATH 1 ft 49.5 ft2 1 0 0 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Laundry 11 ft 71.5 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio BATH 1 5.5 ft 66 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio Master Bed 25.5 ft 162 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulatio M CL 3.5 ft 24.5 ft2 ___ 1 0 0 9 Slab -On -Grade Edge Insulatio BEDROOM 2 24 ft 143.8 ft2 ___ 1 0 0 10SIab-On-Grade Edge Insulatio CL 3 1 ft 15 ft2 1 0 0 11Slab-On-Grade Edge Insulatio CL 2 2.5 ft 16.3 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 ft 61.3 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulatio LIVING ROOM 52 ft 423.3 ft2 ___ 1 0 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1361 ft2 214 ft2 Medium N 0.9 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1291 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 3 30 Blown 131 ft2 0.1 Wood 2 Under Attic (Vented) KITCHEN 30 Blown 116 #2 0.1 Wood 3 Under Attic (Vented) pnty 30 Blown 11 ft2 0.1 Wood 4 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 5 Under Attic (Vented) Laundry 30 Blown 72 ft2 0.1 Wood 6 Under Attic (Vented) BATH 1 30 Blown 66 ft2 0.1 Wood 7 Under Attic (Vented) Master Bed 30 Blown 162 ft2 0.1 Wood 8 Under Attic (Vented) M CL 30 Blown 25 ft2 0.1 Wood 9 Under Attic (Vented) BEDROOM 2 30 Blown 144 ft2 0.1 Wood 10 Under Attic (Vented) CL 3 30 Blown 15 ft2 0.1 Wood 11 Under Attic (Vented) CL 2 30 Blown 16 ft2 0.1 Wood 12 Under Attic (Vented) Hall 30 Blown 61 ft2 0.1 Wood 13 Under Attic (Vented) LIVING ROOM 30 Blown 423 ft2 0.1 Wood 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent 10 Wall TypeSpace Cavity Width R-Vall le Ft In Height Et In Area Sheathing Framing Solar RA/al-fe Fraction AhSor Below Grade%- 1 W Exterior Concrete Block - Int Insi9EDROOM 3 5 10 6 8 0 84.0 ft2 0 0 0.5 0 2 E Exterior Concrete Block - Int Insul KITCHEN 5 % 6 8 0 84.0 ft2 0 0 0.5 0 3 N Garage Concrete Block - Int Insul KITCHEN 5 11 0 8 0 88.0 ft2 0 0 0.5 0 _ 4 E Exterior Concrete Block - Int Insul Laundry 5 11 0 8 0 88.0 ft2 0 0 0.5 0 5 E Exterior Concrete Block - Int Insul BATH 1 5 5 6 8 0 44.0 ft2 0 0 0.5 0 6 E Exterior Concrete Block - Int InsuMaster Bed 5 13 6 8 0 108.0 ft2 0 . 0 0.5 0 7 S Exterior Concrete Block - Int InsuMaster Bed 5 12 0 8 0 96.0 ft2 0 0 0.5 0 8 S Exterior Concrete Block - Int Insul M CL 5 3 6 8 0 28.0 ft2 0 0 0.5 0 9 S Exterior Concrete Block - Int InsdHEDROOM 2 5 12 6 8 0 100.0 ft2 0 0 0.5 0 10 W Exterior Concrete Block - Int InsiMEDROOM 2 5 11 6 8 0 92.0 ft2 0 0 0.5 0 11 W Exterior Concrete Block - Int Insul CL 2 5 2 6 8 0 20.0 ft2 . 0 0 0.5 0 12 N Exterior Concrete Block - Int InsddIVING ROO 5 16 6 8 0 132.0 ft2 0 0 0.5 0 13 W Exterior Concrete Block - Int InstilIVING ROO 5 25 6 8 0 204.0 ft2 0 0 0.5 0 14 E Garage Concrete Block - Int InstiIIVING ROO 5 9 6 8 0 76.0 ft2 0 0 0.5 0 15 N Garage Concrete Block - Int InS81IVING ROO 5 0 6 8 0 4.0 ft2 0 0 0.5 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In. 1 N Wood LIVING ROO None .39 3 7 21 ft2 2 W Wood LIVING ROO None .39 3 2 7 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC, Imp Area Depth Separation Int Shade Screening 1 W 1 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 E 2 None Double (Clear) Yes 0.6 0.24 Y 10.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 S 7 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 S 9 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 N 12 None Double (Clear) Yes 0.6 0.24 Y 24.4 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000355 1204.7 66.14 124.38 .1231 7 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27.3 kBtu/hr 1 sys#1 ' COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 27.6 kBtu/hr cfm 0.72 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Laundry 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply -- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 258 ft2 Attic 64 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin jj jj Jan jj jj Feb jj jj Mar j j A r Jun Jul Au Se j j Oct [ ]Nov Dec Heating [X] Jan [X] Feb [X] Mar [ ]Apr May Jun Jul I jMa rj rl AuSep rl [ ri ]Oct [X] Nov Dec Ventin j ] Jan j ] Feb [X] Mar [X] A r May Jun Jul Aug Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 '78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68. 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 pnty Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 1 DefaulO Ibs/sq.ft. ft2 ft 0.3 Master Bed Default(8 lbs/sq.ft. ft2 ft 0.3 M CL Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CL•3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CL 2 Default(8 Ibs/sq.ft. ft2 ft . 0.3 Hall Default(8 Ibs/s .ft. ft2 ft 0.3 LIVING ROOM 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6