—✓ '' - - wrightsoft� Load Short Form Entire House Webreps LLC 1880 82nd Me, Vero Beach, FI 32966 Phone: (800) 810-3280 ' Job: LOT 5-6 Nollem Drive, Fort... Date: February4, 2021 RECEIVED BY Josh Pulrnan Plan: LOT 5-6 Nodem Drive JUL 15 2021 For: Joseph Gianna, St Lucie Habitat for Humanity . 702 South 6th.Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stluciehabitatorg Design Information Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (°F) 72. 75 Construction quality Semi -tight Design TD (°F) 30 15 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (grAb) 3 61 HEATING EQUIPMENT Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 8.0 WV 27297 Btuh 27. OF 920 cfm 0.049 cfmBtuh 0.60 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160301 F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13.0 EER,16 SEER Sensible cooling - 19872 Btuh Latent,cooling 7728 Btuh Total cooling 27600 Btuh Actual airflow 920 cfm Airflowfactor 0.052 cfm/Btuh Static pressure --- 0.60 in H2O Load sensible heat ratio 0.73 ROOM NAME Area (ft2 Htg load (Btuh) Clg load (Btuh) HtgAVF (cfrn) ClgAVF (cfm) BEDROOM 3 131 1669 2279 81 118 KITCHEN 116 2206 3791 108 196 pnty 11 0 0 0 0 BATH 50 73 280 4 15 Laundry 72 1198 '1149 58 - 60 BATH 1 66 644 312 31 16 Master Bed 162 3261 2456 159 127 M CL 25 0 0 0 0 BEDROOM 2 144 3229. 2114 .. 158 110 CL 3 15 0 0 0, 0 CL 2 16 0 0 0 0 Hall 61 0 0 0 0 1 1%Ilk I!`_ OnnhA A-f4 92=7 C4792 971 77n Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-1215:58:55 `- wrigfltsoft ° Right -Suite® Universal 2021 21.0.03 RSU16998 Page 1 +� h•I Bv.4ni,Y ueewvY�rYarry ACCK ...ity PSLILOT 5-6 Notlem Drive Fort PierceFL_.rup Calc= MJ8 faces: N Entire House 1291 18847 17758 920 920 Other equip loads 122. 1707. Equip. @: 1.00 .: RSM -_ 19465 Latent cooling 7352 TOTALS 1991 1RPR9 �)RR1R 920 920 Calculations approved byACCA to meet all requirements of Manual J 8th Ed: -�-. wrigF�tsoft°' 2021-Feb-1215:58:55 ^L ..10.,Right-Sul"Universal 2021 21.0.03 RSU16998 page 2 fiCCr� ...ity PSLILOT 5-6 Notlem Drive Fort PierceFL_ rup Calc= MJ8 faces: N Summary Project$UrYlllla Job: LOT 5-6NotlemDrive, Fort ... Date: February4, 2021 - wrightsoftm Entire House W. Josh Pul nan Webreps LLC Plan: LOT 5 6 Notlem Drive 1880 82nd foe, Vero Beach, R 32966 Phone: (800) 810-3280 Project• • For. Joseph Gianna St Lucie Habitat for Humanity 702 South 6th Street,. Fort Pierce, FL JUL 15 2021 Phone: (772) 464-1117 Email: joseph@stluciehabitatorg St. Lucia County Notes: LOT 5-6 Notiem Drive,. Fort Pierce-, FL. Permitting Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions: Outside db 42 OF Outside db 90 OF Inside db 72 OF Inside db 75 OF Design TD 30 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 15602 Btuh Structure 12472 Btuh Ducts 3245 Btuh Ducts 5286 Btuh Central vent (0 cim) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 122 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 18969 Btuh Use manufacturer's data y Rate/swing multiplier Equipment sensible load 1.00 19465 Btuh Infiltration Method Simplified Latent Cooling. Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 5850 Btuh Ducts 1501 Btuh Central vent (0 cfm) 0 Btuh Area (M Heating Coming 1291 1291 (none) Equipment latent load 7352 Btuh Volume (f?) 10326 10326 Air changesthour 0.31 0.16 Equipment Total Load (Sen+Lat) 26816 Btuh Equiv. AVF (cfhl) 53 28 Req. total capacity at 0.72 SHR - 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160301 F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 8.0 kW Sensible cooling 19872 Btuh Heating output 27297 Btuh Latentcooling 7728 Btuh Temperature rise 27 OF Total cooling 27600 Btuh Actual airflow 920 cirn Actual airflow 920 cfm Air flowfactor 0.049 cfmBtuh Airflowfactor 0.052 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.73 Calculations approved byACCA to meet all requirements of Manual J 8th Ed.. wrightsoft- 2021-Feb-1215:58:55 Right Suite® Universal 202121.0.03 RSU76998 Page 1 ACCK ...ity PSLIOT 5-6 Notiem Drive Fort PierceFL_ rup Calc= MJ8 faces: N N 16" MAIN FLOOR Job #: LOT 6-6 Notlem Drive,.Fort Pierce, FL Webreps LLC Scale: 1 : 86 Performed by Josh Putman for: Page 1 Joseph Gianna 1880 82ndAve Right Suite® Universal 2021 -702 South 6th Street Mero Beach, FI 32966 21.0.03 RSU16998 Fort Pierce, Fl- Phone: (800) 810-3280 2021-Feb-1215:59:02 Phone: (772) 464-1117 Notlem Drive Fort PieroeFL_ rup joseph@stluciehabitatorg _nl Duct$ stern Summary Job: LOT 5-6NotlernDrive, Fort ... wrightsoft`� y ri Date: February 4, 2021 Entire House %r Josh Putman Webreps LLC Plan: LOT 5-6 Notlem Drive 1880 82nd Are, Vero Beach, R 32966 Phone: (800) 810-3280 eLroject intormation For. Joseph Gianna, St Lucie.Habitatfor Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stluciehabitatorg External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0,24 in H2O 0.36 - in H2O 0.260 / 0.100 i n H2O 0.099 in/100ft 920 cfm 363 ft Supply Branch Detail Table Cooling 0.60 in H2O ' 0.24 in H2O 0.36 in H2O 0.260 / 0.100 in H2O 0.099 in/100ft 920 clin Name Design (Btuh) Htg - (cfm) Clg (cfm) Design FIR(in) Diam H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BAH c 280 4 15 0.146_ 4.0 Ox0 VIFx 23.0 155.0 st2 BRdH 1 h 644 31 16 0.101 4.0 Ox 0 VI Fx 37.3 220.0 st3 BEDROOM 2 h 3229 158 110 0.099 7.0 Ox 0 VIFx 42.8 220.0 st3 BEDROOM3 c 2279 81 118 0.099 6.0 Ox0 VIFx 42.4 220.0 st3 KrrCHEN c 3791 108 196 0.233 8.0 Ox0 VIFx 6.9 105.0 LIVINGROOM h 2189 107 93 0.141 6.0 Ox 0 VIFx 19.2 165.0 st1 LIVING ROOWA h 2189 107 93 0.138 6.0 'Ox 0 VIFx 23.0 165.0 st1 LIVING ROOM-B h 2189 107 93 0.131 6.0 Ox 0 VIFx 29.5 170.0 st1 Laundry c 1149 58 60 0.133 4.0 Ox0 VIFx 26.5 170.0 st2 Master Bed h 3261 159 127 0.100 .7.0 Ox0 VIFx 40.5 220.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (dim) FIR(iprti) (in) (in) Material Trunk st1 PeakAVF 321 279 0.131 588 10.0 0 x 0 VinlFlx st3 PeakAVF 430 371 0.099 547 12.0 0 x 0 VinlFlx st2 st2 PeakAVF 492 445 0.099 626 12.0 0 x 0 VinlFlx wrightsoft" 2021-Feb-1115:58:55 R ight-Suite®Universal2021 21.0.03 RSU16998 Page 1 AM....ityPSLIOT5-6Notlern Drive Fort PierceFL_.rup Calc=MJ8 faces: N. Return Branch Detail Table Name Grille Size (in) : Htg (cim) Clg (cfm) TEL (it) Design FR. Veloc (fpm) Diam (in) H x W . - (in) Stud/Joist Opening (in) Duct Mat Trunk rb4 Ox 0 920 920 100.5 0.099 659 16.0 Ox 0 VIFx -*-- wrightsoft 2021-Feb-1215:58:55 Right Suite® Universal 202121.0.03 RSU16998 Page ACCK ..:ity PSLILOT 5-6 Notlem Drive Fort PierceFL_.rup Calc= MJ8 faces: N