HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: GARCIA RESIDENCE
Builder Name:
Street: LINWOOD AVENUE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: MANUEL AND MARIA GARCIA
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or eAsting New (From Plans)
10. Wall Types(2689.5 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2489.50 ft2
b. Frame - Wood, Adjacent
R=11.0 200.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (2675.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2675.00 ft2
6. Conditioned floor area above grade (ft2) 2675
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows (406.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
R ft2
RM 6 150
a. U-Factor: Sgl, U=0.29 406.00 ft2
SHGC: SHGC=0.22
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
42.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 5.224 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.220
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2675.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2675.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.152 Total Proposed Modified Loads: 80.56
PASS
Total Baseline Loads: 86.57
I hereby certify that the plans and specifications covered by
Review of the plans and
11JE S?^,
this calculation are in compliance with the Florida Energy
specifications covered by this
O�
y
Code.
calculation indicates compliance��
{
PREPARED gY:
with the Florida Energy Code.
Before is
r+n,ru'?.- = �° .��`=',N O
' to
DATE: 5-P(0-2024
construction completed
this building will be inspected for
compliance with Section 553.908
�
hereby certify that this building, as designed, is in compliance
the Florida Energy Code.
Florida Statutes.
5�
COD
with
we
OWNER/AGENT-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
GARCIA RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2675
Lot #
Owner Name:
MANUEL AND MARIA GARCI
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
LINWOOD AVENUE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Ebsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2675
27684.5
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
KITCHEN/DINING
510
5100 Yes
0
1
Yes
Yes
Yes
2
LIVING RM
523
6015 No
0
1
Yes
Yes
Yes
3
DEN
168
1680 No
0
1
Yes
Yes
Yes
4
BEDROOM 4
186
1860 No
0
1
1
Yes
Yes
Yes
5
CLST 4
22
220 No
0
1
Yes
Yes
Yes
6
BEDROOM 3
144
1440 No
0
1
1
Yes
Yes
Yes
7
WIC 3
49
490 No
0
1
Yes
Yes
Yes
8
BATH 3
63
630 No
0
1
No
Yes
Yes
9
HALLWAY
68
680 No
0
1
No
Yes
Yes
10
FOYER
100
1150 No
0
1
Yes
Yes
Yes
11
STORAGE
30
300 No
0
1
No
Yes
Yes
12
BATH 2
40
400 No
0
1
No
Yes
Yes
13
WIC 2
30
300 No
0
1
Yes
Yes
Yes
14
BEDROOM 2
138
1380 No
0
1
1
Yes
Yes
Yes
15
LAUNDRY RM
64
640 No
0
1
Yes
Yes
Yes
16
HALL
18
180 No
0
1
No
Yes
Yes
17
M BATH
145
1450 No
0
1
Yes
Yes
Yes
18
M TOILET
30
300 No
0
1
No
Yes
Yes
19
M W IC 2
42
420 No
0
1
No
Yes
Yes
20
M WIC 1
48
480 No
0
1
Yes
Yes
Yes
21
MASTER BEDROO
257
2570 No
0
1
1
Yes
Yes
Yes
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
KITCHEN/DININ
60 ft
510 ft2
1
0 0
2 Slab -On -Grade Edge Insulation
LIVING RM
23 ft
523 ft2
____
1
0 0
3 Slab -On -Grade Edge Insulation
DEN
12 ft
168 ft2
____
1
0 0
4 Slab -On -Grade Edge Insulation
BEDROOM 4
27 ft
186 ft2
1
0 0
5 Slab -On -Grade Edge Insulation
CLST 4
2 ft
22 ft2
__e
1
0 0
6 Slab -On -Grade Edge Insulation
BEDROOM 3
24 ft
144 ft2
�e
1
0 0
7 Slab -On -Grade Edge Insulation
WIC 3
6 ft
49 ft2
1
0 0
8 Slab -On -Grade Edge Insulation
BATH 3
1 ft
63 ft2
1
0 0
9 Slab -On -Grade Edge Insulation
HALLWAY
1 ft
68 ft2
____
1
0 0
10SIab-On-Grade Edge Insulation
FOYER
loft
100 ft2
1
0 0
11SIab-On-Grade Edge Insulation
STORAGE
1 ft
30 ft2
____
1
0 0
12SIab-On-Grade Edge Insulation
BATH 2
1 ft
40 ft2
ee
1
0 0
13SIab-On-Grade Edge Insulation
WIC 2
5 ft
30 ft2
____
1
0 0
14SIab-On-Grade Edge Insulation
BEDROOM 2
11 ft
138 ft2
____
1
0 0
15SIab-On-Grade Edge Insulation
LAUNDRY RM
4 ft
64 ft2
1
0 0
16SIab-On-Grade Edge Insulation
HALL
1 ft
18 ft2
__e
1
0 0
17SIab-On-Grade Edge Insulation
M BATH
9 ft
145 ft2
1
0 0
18SIab-On-Grade Edge Insulation
M TOILET
1 ft
30 ft2
1
0 0
19SIab-On-Grade Edge Insulation
M W IC 2
1 ft
42 ft2
____
1
0 0
20SIab-On-Grade Edge Insulation
M W IC 1
8 ft
48 ft2
____
1
0 0
21SIab-On-Grade Edge Insulation
MASTER BEDRO
43 ft
257 ftz
__e
1
0 0
ROOF
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck Pitch
V # Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 2991 ft2
0 ft2 Light
N
0.3 No 0.9
No
20 26.57
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0
2675 ft2
N N
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) KITCHEN/DININ
0
Blown
510 ftz
0.1
Wood
2
Under Attic (Unvented) LIVING RM
0
Blown
523 ft2
0.1
Wood
3
Under Attic (Unvented) DEN
0
Blown
168 ftz
0.1
Wood
4
Under Attic (Unvented) BEDROOM 4
0
Blown
186 ftz
0.1
Wood
5
Under Attic (Unvented) CLST 4
0
Blown
22 ftz
0.1
Wood
6
Under Attic (Unvented) BEDROOM 3
0
Blown
144 ftz
0.1
Wood
7
Under Attic (Unvented) WIC 3
0
Blown
49 ftz
0.1
Wood
8
Under Attic (Unvented) BATH 3
0
Blown
63 ftz
0.1
Wood
9
Under Attic (Unvented) HALLWAY
0
Blown
68 ftz
0.1
Wood
10
Under Attic (Unvented) FOYER
0
Blown
100ft2
0.1
Wood
11
Under Attic (Unvented) STORAGE
0
Blown
30ft2
0.1
Wood
12
Under Attic (Unvented) BATH 2
0
Blown
40 ftz
0.1
Wood
13
Under Attic (Unvented) WIC 2
0
Blown
30 ftz
0.1
Wood
14
Under Attic (Unvented) BEDROOM 2
0
Blown
138 ftz
0.1
Wood
15
Under Attic (Unvented) LAUNDRY RM
0
Blown
64 ftz
0.1
Wood
16
Under Attic (Unvented) HALL
0
Blown
18 ftz
0.1
Wood
17
Under Attic (Unvented) M BATH
0
Blown
145 ftz
0.1
Wood
18
Under Attic (Unvented) M TOILET
0
Blown
30 ftz
0.1
Wood
19
Under Attic (Unvented) M W IC 2
0
Blown
42 ftz
0.1
Wood
20
Under Attic (Unvented) M WIC 1
0
Blown
48ft2
0.1
Wood
21
Under Attic (Unvented) MASTER BEDRO
0
Blown
257 ftz
0.1
Wood
WALLS
Adjacent Space
Cavity
Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block - Int InsuKITCHEN/DI
4.1
15
0 10
0
150.0 ftz
0
0
0.3
0
2
E
Exterior Concrete Block - Int InsuKITCHEN/DI
4.1
11
0 10
0
110.0 ftz
0
0
0.3
0
3
W
Exterior Concrete Block - Int InsuKITCHEN/DI
4.1
34
0 10
0
340.0 ftz
0
0
0.3
0
4
N
Exterior Concrete Block - Int Insul LIVING RM
4.1
23
0 11
6
264.5 ftz
0
0
0.3
0
5
W
Exterior Concrete Block - Int Insul DEN
4.1
12
0 10
0
120.0 ftz
0
0
0.3
0
6
S
Exterior Concrete Block - Int InsuBEDROOM 4
4.1
11
0 10
0
110.0 ftz
0
0
0.3
0
7
W
Exterior Concrete Block - Int InsuBEDROOM 4
4.1
16
0 10
0
160.0 ftz
0
0
0.3
0
8
S
Exterior Concrete Block - Int Insul CLST 4
4.1
2
0 10
0
20.0 ftz
0
0
0.3
0
9
E
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
12
0 10
0
120.0 ftz
0
0
0.3
0
10
S
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
12
0 10
0
120.0 ftz
0
0
0.3
0
11
E
Exterior Concrete Block- Int Insul WIC 3
4.1
6
0 10
0
60.0 ftz
0
0
0.3
0
12
S
Exterior Concrete Block - Int Insul FOYER
4.1
10
0 11
6
115.0 ftz
0
0
0.3
0
13
E
Exterior Concrete Block- Int Insul WIC 2
4.1
5
0 10
0
50.0 ftz
0
0
0.3
0
14
E
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
11
0 10
0
110.0 ftz
0
0
0.3
0
15
S
Garage Frame- Wood BEDROOM 2
11
12
0 10
0
120.0 ftz
0
0.1
0.3
0
16
W
Exterior Concrete Block - Int InsuLAUNDRY R
4.1
4
0 10
0
40.0 ftz
0
0
0.3
0
17
S
Garage Frame - Wood LAUNDRY R
11
8
0 10
0
80.0 ftz
0
0.1
0.3
10
18
E
Exterior Concrete Block - Int Insul M BATH
4.1
9
0 10
0
90.0 ftz
0
0
0.3
0
19
E
Exterior Concrete Block - Int Insul M WIC 1
4.1
8
0 10
0
80.0 ftz
0
0
0.3
0
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
-FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Below
SpaceRAlaille
le
rea
qnr20
N
Exterior
Concrete
Block - Int InsuMASTER
BE 4.1 17
0 10
0
170.0 ftz
0
0 0.3
0
21 E
Exterior
Concrete
Block - Int InsuMASTER
BE 4.1 15
0 10
0
150.0 ftz
0
0 0.3
0
22 W
Exterior
Concrete Block - Int InsuMASTER BE 4.1 11
0 10
0
110.0 ftz
0
0 0.3
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
LAUNDRY R
None
.23
2
8
7 8
20.4 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V/ #
Omt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl
Low-E Single
Yes
0.29 0.22
Y
30.0 ftz
1 ft 6 in
1 ft 4 in
None
None
2
W 3
Vinyl
Low-E Single
Yes
0.29 0.22
Y
40.0 ftz
1 ft 6 in
1 ft 4 in
None
None
3
N 4
Vinyl
Low-E Single
Yes
0.29 0.22
Y
96.0 ftz
13 ft 6 in
1 ft 4 in
None
None
4
W 5
Vinyl
Low-E Single
Yes
0.29 0.22
Y
20.0 ft'
1 ft 6 in
1 ft 4 in
None
None
5
S 6
Vinyl
Low-E Single
Yes
0.29 0.22
Y
30.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
W 7
Vinyl
Low-E Single
Yes
0.29 0.22
Y
20.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
7
S 10
Vinyl
Low-E Single
Yes
0.29 0.22
Y
30.0 ftz
1 ft 6 in
1 ft 4 in
None
None
8
S 12
Vinyl
Low-E Single
Yes
0.29 0.22
Y
40.0 ftz
10 ft 6 in
1 ft 4 in
None
None
9
E 14
Vinyl
Low-E Single
Yes
0.29 0.22
Y
20.0 ftz
1 ft 6 in
1 ft 4 in
None
None
10
E 18
Vinyl
Low-E Single
Yes
0.29 0.22
Y
20.0 ft'
1 ft 6 in
1 ft 4 in
None
None
11
N 20
Vinyl
Low-E Single
Yes
0.29 0.22
Y
30.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
12
E 21
Vinyl
Low-E Single
Yes
0.29 0.22
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
None
None
13
E 21
Vinyl
Low-E Single
Yes
0.29 0.22
Y
15.0 ftz
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
420 ftz
420 ftz
20 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 W holehouse Proposed ACH(50)
.000329
2307.1 126.57
237.63
.1
5
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020
INPUT SUMMARY GHF-GKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16
42 kBtu/hr
1260 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply --
---- Return---
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 150 ft2
Attic
15 ft2 Default Leakage
LAUNDRY
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb
HeatinH Jan HFeb
[[ ]] Mar
[X] Mar
Apr
Apr
May [X] Jun Jul
May [ ] Jun f Jul
Auge
f AuSeP
[ ] Oct
[ ] Oct f X}
Nov
Nov
Dec
Dec
Vent! n Jan Feb
[[XX]] Mar
Apr
[ May [ ]Jun [ Jul
L
[ Aug
Se
[X] Oct [X]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
Heating (WEH) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LIVING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STORAGE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
r)of=1IWA lhclqn ft
ft2
ft
0.3
MASTER BEDROO
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: GARCIA RESIDENCE Builder Name:
Street: LINWOOD AVENUE Permit Office:' ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner: MANUEL AND MARIA GARCIA Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind 00na and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
i
i
■■I■■1■I■■1--7■I■■I■■■
s■
■■I■■I■II--N■I■I■■I
i
�III1
■_
III
G
■
�_
■
■
III
■
■
■
IIIFLAT
ClG
MIN
C
r (
12'SLDG DR
irlrrl■■le
IIII
LIVING ROOM
I♦�.YL •J�:
'o
IIIITCHE
...1
I I "
F.
IIIIIIIIII
1 1 •�'
�
k WOO
� �
�
IIII
' •
�
1 ■
`�
Cov
■
�
.Ilr
�
I■■It
■I■■I■1=-I■■I■I■I■I■■■■■I--I■■I■It
I
TABULATION AREA
LIVING AREA 2675 SF
COVERED FRONT ENTRY BISF
COVERED PORCH 320SF
GARAGE 451 SF
TOTAL 3527 SF
PROTECTION OF OPENINGS:
NOTE:
BLOCK LAYERS/FRAMERS TO CONSULT W/CONTRACTOR
FOR ROUGH OPENINGS OF WINDOWS AND DOORS
DOOR SCHEDULE
ORO
SIZE VxH
ROUGH OP
QUANTITY
REMARKS
DI
DI
2-3'0'%7'8'Xl 3/4'
6'0'xl8'
6'3'X7.11'
6'2'x20'
1
. 1
EXTERIOR ➢R n/TRANSOM
TRANSOM
D2
2'8"X7'8"Xl 3/8"
34x93-
9
INTERIOR ➢R 6 PANEL
D3
2'6"X7'8" %l 3/8"
32'x93-
7
INTERIOR DR 6 PANEL
D4
4•.9 '
1
GA. OR -I MR FIRCRATED
..
,.
I
n.
D6
1210-X810'
1
1 ' SLIDING DR
WINDOW SCHEDULE
SCALE 1/4"=1'0"
FIRE SAFETY OPENING
EGRESS VINDOVS IN SLEEPING ROOM
MUST HAVE A MINIMUM CLEAR OPENING
'HEIGHT OF 24' 6 A MIN NET CLEAR
WIDTH OF 20'. NET CLEAR OPENING
AREA SHALL A MIN OF 5-SG FT.
ON GROUND FLOOR 5.7 SO, FT. ABOVE
GROUND LEVEL MAX SILL HEIGHT 44
ABOVE FFE