Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GARCIA RESIDENCE Builder Name: Street: LINWOOD AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: MANUEL AND MARIA GARCIA Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting New (From Plans) 10. Wall Types(2689.5 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2489.50 ft2 b. Frame - Wood, Adjacent R=11.0 200.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (2675.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2675.00 ft2 6. Conditioned floor area above grade (ft2) 2675 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows (406.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY R ft2 RM 6 150 a. U-Factor: Sgl, U=0.29 406.00 ft2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.224 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.220 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2675.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2675.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.152 Total Proposed Modified Loads: 80.56 PASS Total Baseline Loads: 86.57 I hereby certify that the plans and specifications covered by Review of the plans and 11JE S?^, this calculation are in compliance with the Florida Energy specifications covered by this O� y Code. calculation indicates compliance�� { PREPARED gY: with the Florida Energy Code. Before is r+n,ru'?.- = �° .��`=',N O ' to DATE: 5-P(0-2024 construction completed this building will be inspected for compliance with Section 553.908 � hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. 5� COD with we OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GARCIA RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2675 Lot # Owner Name: MANUEL AND MARIA GARCI Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LINWOOD AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2675 27684.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN/DINING 510 5100 Yes 0 1 Yes Yes Yes 2 LIVING RM 523 6015 No 0 1 Yes Yes Yes 3 DEN 168 1680 No 0 1 Yes Yes Yes 4 BEDROOM 4 186 1860 No 0 1 1 Yes Yes Yes 5 CLST 4 22 220 No 0 1 Yes Yes Yes 6 BEDROOM 3 144 1440 No 0 1 1 Yes Yes Yes 7 WIC 3 49 490 No 0 1 Yes Yes Yes 8 BATH 3 63 630 No 0 1 No Yes Yes 9 HALLWAY 68 680 No 0 1 No Yes Yes 10 FOYER 100 1150 No 0 1 Yes Yes Yes 11 STORAGE 30 300 No 0 1 No Yes Yes 12 BATH 2 40 400 No 0 1 No Yes Yes 13 WIC 2 30 300 No 0 1 Yes Yes Yes 14 BEDROOM 2 138 1380 No 0 1 1 Yes Yes Yes 15 LAUNDRY RM 64 640 No 0 1 Yes Yes Yes 16 HALL 18 180 No 0 1 No Yes Yes 17 M BATH 145 1450 No 0 1 Yes Yes Yes 18 M TOILET 30 300 No 0 1 No Yes Yes 19 M W IC 2 42 420 No 0 1 No Yes Yes 20 M WIC 1 48 480 No 0 1 Yes Yes Yes 21 MASTER BEDROO 257 2570 No 0 1 1 Yes Yes Yes 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN/DININ 60 ft 510 ft2 1 0 0 2 Slab -On -Grade Edge Insulation LIVING RM 23 ft 523 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation DEN 12 ft 168 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 4 27 ft 186 ft2 1 0 0 5 Slab -On -Grade Edge Insulation CLST 4 2 ft 22 ft2 __e 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 3 24 ft 144 ft2 �e 1 0 0 7 Slab -On -Grade Edge Insulation WIC 3 6 ft 49 ft2 1 0 0 8 Slab -On -Grade Edge Insulation BATH 3 1 ft 63 ft2 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 68 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation FOYER loft 100 ft2 1 0 0 11SIab-On-Grade Edge Insulation STORAGE 1 ft 30 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BATH 2 1 ft 40 ft2 ee 1 0 0 13SIab-On-Grade Edge Insulation WIC 2 5 ft 30 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 11 ft 138 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation LAUNDRY RM 4 ft 64 ft2 1 0 0 16SIab-On-Grade Edge Insulation HALL 1 ft 18 ft2 __e 1 0 0 17SIab-On-Grade Edge Insulation M BATH 9 ft 145 ft2 1 0 0 18SIab-On-Grade Edge Insulation M TOILET 1 ft 30 ft2 1 0 0 19SIab-On-Grade Edge Insulation M W IC 2 1 ft 42 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation M W IC 1 8 ft 48 ft2 ____ 1 0 0 21SIab-On-Grade Edge Insulation MASTER BEDRO 43 ft 257 ftz __e 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2991 ft2 0 ft2 Light N 0.3 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2675 ft2 N N 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN/DININ 0 Blown 510 ftz 0.1 Wood 2 Under Attic (Unvented) LIVING RM 0 Blown 523 ft2 0.1 Wood 3 Under Attic (Unvented) DEN 0 Blown 168 ftz 0.1 Wood 4 Under Attic (Unvented) BEDROOM 4 0 Blown 186 ftz 0.1 Wood 5 Under Attic (Unvented) CLST 4 0 Blown 22 ftz 0.1 Wood 6 Under Attic (Unvented) BEDROOM 3 0 Blown 144 ftz 0.1 Wood 7 Under Attic (Unvented) WIC 3 0 Blown 49 ftz 0.1 Wood 8 Under Attic (Unvented) BATH 3 0 Blown 63 ftz 0.1 Wood 9 Under Attic (Unvented) HALLWAY 0 Blown 68 ftz 0.1 Wood 10 Under Attic (Unvented) FOYER 0 Blown 100ft2 0.1 Wood 11 Under Attic (Unvented) STORAGE 0 Blown 30ft2 0.1 Wood 12 Under Attic (Unvented) BATH 2 0 Blown 40 ftz 0.1 Wood 13 Under Attic (Unvented) WIC 2 0 Blown 30 ftz 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 0 Blown 138 ftz 0.1 Wood 15 Under Attic (Unvented) LAUNDRY RM 0 Blown 64 ftz 0.1 Wood 16 Under Attic (Unvented) HALL 0 Blown 18 ftz 0.1 Wood 17 Under Attic (Unvented) M BATH 0 Blown 145 ftz 0.1 Wood 18 Under Attic (Unvented) M TOILET 0 Blown 30 ftz 0.1 Wood 19 Under Attic (Unvented) M W IC 2 0 Blown 42 ftz 0.1 Wood 20 Under Attic (Unvented) M WIC 1 0 Blown 48ft2 0.1 Wood 21 Under Attic (Unvented) MASTER BEDRO 0 Blown 257 ftz 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 15 0 10 0 150.0 ftz 0 0 0.3 0 2 E Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 3 W Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 34 0 10 0 340.0 ftz 0 0 0.3 0 4 N Exterior Concrete Block - Int Insul LIVING RM 4.1 23 0 11 6 264.5 ftz 0 0 0.3 0 5 W Exterior Concrete Block - Int Insul DEN 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 6 S Exterior Concrete Block - Int InsuBEDROOM 4 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 7 W Exterior Concrete Block - Int InsuBEDROOM 4 4.1 16 0 10 0 160.0 ftz 0 0 0.3 0 8 S Exterior Concrete Block - Int Insul CLST 4 4.1 2 0 10 0 20.0 ftz 0 0 0.3 0 9 E Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 10 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 11 E Exterior Concrete Block- Int Insul WIC 3 4.1 6 0 10 0 60.0 ftz 0 0 0.3 0 12 S Exterior Concrete Block - Int Insul FOYER 4.1 10 0 11 6 115.0 ftz 0 0 0.3 0 13 E Exterior Concrete Block- Int Insul WIC 2 4.1 5 0 10 0 50.0 ftz 0 0 0.3 0 14 E Exterior Concrete Block - Int InsuBEDROOM 2 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 15 S Garage Frame- Wood BEDROOM 2 11 12 0 10 0 120.0 ftz 0 0.1 0.3 0 16 W Exterior Concrete Block - Int InsuLAUNDRY R 4.1 4 0 10 0 40.0 ftz 0 0 0.3 0 17 S Garage Frame - Wood LAUNDRY R 11 8 0 10 0 80.0 ftz 0 0.1 0.3 10 18 E Exterior Concrete Block - Int Insul M BATH 4.1 9 0 10 0 90.0 ftz 0 0 0.3 0 19 E Exterior Concrete Block - Int Insul M WIC 1 4.1 8 0 10 0 80.0 ftz 0 0 0.3 0 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 -FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceRAlaille le rea qnr20 N Exterior Concrete Block - Int InsuMASTER BE 4.1 17 0 10 0 170.0 ftz 0 0 0.3 0 21 E Exterior Concrete Block - Int InsuMASTER BE 4.1 15 0 10 0 150.0 ftz 0 0 0.3 0 22 W Exterior Concrete Block - Int InsuMASTER BE 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated LAUNDRY R None .23 2 8 7 8 20.4 ftz WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ftz 1 ft 6 in 1 ft 4 in None None 2 W 3 Vinyl Low-E Single Yes 0.29 0.22 Y 40.0 ftz 1 ft 6 in 1 ft 4 in None None 3 N 4 Vinyl Low-E Single Yes 0.29 0.22 Y 96.0 ftz 13 ft 6 in 1 ft 4 in None None 4 W 5 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft' 1 ft 6 in 1 ft 4 in None None 5 S 6 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 6 W 7 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 7 S 10 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ftz 1 ft 6 in 1 ft 4 in None None 8 S 12 Vinyl Low-E Single Yes 0.29 0.22 Y 40.0 ftz 10 ft 6 in 1 ft 4 in None None 9 E 14 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ftz 1 ft 6 in 1 ft 4 in None None 10 E 18 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft' 1 ft 6 in 1 ft 4 in None None 11 N 20 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 E 21 Vinyl Low-E Single Yes 0.29 0.22 Y 15.0 ftz 1 ft 6 in 1 ft 4 in None None 13 E 21 Vinyl Low-E Single Yes 0.29 0.22 Y 15.0 ftz 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ftz 420 ftz 20 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 W holehouse Proposed ACH(50) .000329 2307.1 126.57 237.63 .1 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY GHF-GKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply -- ---- Return--- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage LAUNDRY (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinH Jan HFeb [[ ]] Mar [X] Mar Apr Apr May [X] Jun Jul May [ ] Jun f Jul Auge f AuSeP [ ] Oct [ ] Oct f X} Nov Nov Dec Dec Vent! n Jan Feb [[XX]] Mar Apr [ May [ ]Jun [ Jul L [ Aug Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING RM Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 STORAGE Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 r)of=1IWA lhclqn ft ft2 ft 0.3 MASTER BEDROO 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GARCIA RESIDENCE Builder Name: Street: LINWOOD AVENUE Permit Office:' ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: MANUEL AND MARIA GARCIA Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind 00na and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/7/2021 12:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 i i ■■I■■1■I■■1--7■I■■I■■■ s■ ■■I■■I■II--N■I■I■■I i �III1 ■_ III G ■ �_ ■ ■ III ■ ■ ■ IIIFLAT ClG MIN C r ( 12'SLDG DR irlrrl■■le IIII LIVING ROOM I♦�.YL •J�: 'o IIIITCHE ...1 I I " F. IIIIIIIIII 1 1 •�' � k WOO � � � IIII ' • � 1 ■ `� Cov ■ � .Ilr � I■■It ■I■■I■1=-I■■I■I■I■I■■■■■I--I■■I■It I TABULATION AREA LIVING AREA 2675 SF COVERED FRONT ENTRY BISF COVERED PORCH 320SF GARAGE 451 SF TOTAL 3527 SF PROTECTION OF OPENINGS: NOTE: BLOCK LAYERS/FRAMERS TO CONSULT W/CONTRACTOR FOR ROUGH OPENINGS OF WINDOWS AND DOORS DOOR SCHEDULE ORO SIZE VxH ROUGH OP QUANTITY REMARKS DI DI 2-3'0'%7'8'Xl 3/4' 6'0'xl8' 6'3'X7.11' 6'2'x20' 1 . 1 EXTERIOR ➢R n/TRANSOM TRANSOM D2 2'8"X7'8"Xl 3/8" 34x93- 9 INTERIOR ➢R 6 PANEL D3 2'6"X7'8" %l 3/8" 32'x93- 7 INTERIOR DR 6 PANEL D4 4•.9 ' 1 GA. OR -I MR FIRCRATED .. ,. I n. D6 1210-X810' 1 1 ' SLIDING DR WINDOW SCHEDULE SCALE 1/4"=1'0" FIRE SAFETY OPENING EGRESS VINDOVS IN SLEEPING ROOM MUST HAVE A MINIMUM CLEAR OPENING 'HEIGHT OF 24' 6 A MIN NET CLEAR WIDTH OF 20'. NET CLEAR OPENING AREA SHALL A MIN OF 5-SG FT. ON GROUND FLOOR 5.7 SO, FT. ABOVE GROUND LEVEL MAX SILL HEIGHT 44 ABOVE FFE