Loading...
HomeMy WebLinkAboutProduct Approval; Single Hung Window5/11/2021 BCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats & Facts Publications Contact Us BCIS Site Map Links Search Flarda Product Approval ir USER: Public User Olt M1, t ad n RECIRW© Product Approval Menu > Product or Application Search > Application List > Application Detail Florida Building Code Online FL # FL14095-R11 ORN Application Type Affirmation FilliMitting Depa tment Code Version 2020 St. Lurie Country Application Status Approved Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800) 535-3936 customerserviceagents@jeld-wen.com Windows Single Hung Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Ul I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes O No "", N/A https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCBylJkAudaJDrMRebwM6Myjhkt%2fi64UAxJfBsA%3d%3d 1/3 5/11/2021 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 07/29/2020 Date Validated 07/29/2020 Date Pending FBC Approval Date Approved 07/31/2020 Summary of Products FL # Model, Number or Name Description 14095.1 Premium Atlantic Vinyl Single Hung (8100) 36" x 72" Insulated Glass (5/16 in PVB or SGP Lam - 1/8 out Annealed ) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 R11 C CAC NI011567.04-R3.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2025 Design Pressure: +65/-70 Installation Instructions Other: Laminated glazing interlayer material requirements FL14095 R11 II FL14095 R5 II DP65- meet the current edition of the FBC in accordance with Miami- 70 36x72 Impact Installation Instructions. pdf Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. FL14095 Rll II NI011567.04-113 Dwgs 07252017.pdf Verified By: Hermes Norero, PE 73778 White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NOA for Quanex. IG back Created by Independent Third Party: Yes bedded with Dow 995. Safety glazing required to the exterior at Evaluation Reports heights above 30 feet. FL14095 R11 AE PER3094.pdf Created by Independent Third Party: Yes 14095.2 Premium Atlantic Vinyl Single Hung (8100) 36" x 72" Insulated Glass (1/8 in - 1/8 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 R11 C CAC NI011567.08-RI.pddf Approved for use outside HVHZ: Yes FL14095 R11 C CAC NI011567.09-R2.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +65/-70 04/30/2025 Other: White PVC exterior extrusion meet the current edition Installation Instructions of the FBC in accordance with Miami -Dade NOA for Quanex. IG FL14095 Rll II NI011567.09-R2 Dwgs 07252017.pdf back bedded with Dow 995. Safety glazing required to the FL14095 Rll II PAV TSH FBC 36x72 SS 2017-06-26.pdf Verified By: Hermes Norero, PE 73778 exterior at heights above 30 feet. Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER4869 SS 2017-06-26.pdf Created by Independent Third Party: Yes 14095.3 Premium Atlantic Vinyl Single Hung (8100) 52 1/8" x 75" Insulated Glass (3/16 in - 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 Rll C CAC NI011567.06-Rl.pdf Approved for use outside HVHZ: Yes FL14095 Rll C CAC NI011567.07-R2.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +65/-70 04/30/2025 Other: White PVC exterior extrusion meet the current edition Installation Instructions of the FBC in accordance with Miami -Dade NOA for Quanex. IG FL14095 Rli II NI011567.07-R2 Dwgs 07252017.12-df FL14095 R11 II PAV TSH FBC 52x75 SS 2017-06-26.pdf back bedded with Dow 995. Windows with insulated glass wider Verified By: Hermes Norero, PE 73778 than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER4870 SS 2017-06-26.pd Created by Independent Third Party: Yes 14095.4 Premium Atlantic Vinyl Single Hung (8100) 52 1/8" x 75" Insulated Glass (5/16 in PVB or SGP Lam - 1/8 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL14095 R11 C CAC NI011567.02-112.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 04/30/2025 Design Pressure: +50/-60 Installation Instructions Other: Laminated glazing interlayer material requirements FL14095 R11 II FL14095 R5 II D1350- meet the current edition of the FBC in accordance with Miami- 60 52.125x75 Impact Installation Instructions.pdf FL14095 Rll II NI011567.02-R2 Dwgs 07252017.pdf Dade NOA for DuPont SentryGlas and DuPont PVB interlayers. Verified By: Hermes Norero, PE 73778 White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NOA for Quanex. IG back Created by Independent Third Party: Yes' bedded with Dow 995. Windows with insulated glass wider than Evaluation Reports 36" require setting blocks. Safety glazing required to the FL14095 R11 AE PER3091.pdf exterior at heights above 30 feet. Created by Independent Third Party: Yes 14095.5 Premium Atlantic Vinyl Single Hung (8100) 52 1/8" x 75" Insulated Glass (5/16 in SGP Lam - 3/16 out Annealed) https://www.floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgtGLR%2byCBylJkAudaJDrMRebwM6Myjhkt%2fi64UAxJfBsA%3d%3d 2/3 5/11/2021 Florida Building Code Online Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-75 Other: Laminated glazing interlayer material requirements meet the current edition of the FBC in accordance with Miami - Dade NCA for DuPont SentryGlas and DuPont PVB interlayers. White PVC exterior extrusion meet the current edition of the FBC in accordance with Miami -Dade NCA for Quanex. IG back bedded with Dow 995. Windows with insulated glass wider than 36" require setting blocks. Safety glazing required to the exterior at heights above 30 feet. Certification Agency Certificate FL14095 R11 C CAC NI011567.01-R1.pdf FL14095 R11 C CAC NI011567-Rl.pdf Quality Assurance Contract Expiration Date 04/30/2025 Installation Instructions FL14095 R11 II FL14095 R5 II DP65- 75 52.125x75 Impact Installation Instructions.p—df FL14095 R11 II NI011567.01-R1 Dwgs07252017.pd Verified By: Hermes Norero, PE 73778 Created by Independent Third Party: Yes Evaluation Reports FL14095 R11 AE PER3095.pdf Created by Independent Third Parry: Yes M Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Cop�Lright 2007-2013 State of Florida.:: Privac Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M W ® cGhecA -Y^ :Qr6dt e a Sid https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtGLR%2byCBylJkAudaJDrMRebwM6Myjhkt%2fi64UAxJfBsA%3d%3d 3/3 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Product rod €EvaluationReport o Of JELD-WEN, Inc. 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buiIdingdrops.com Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Current Florida Building Code Method: 1— A (Certificate) Category: Windows Sub = Category: Single Hung Product: Premium Atlantic Vinyl Single Hung - Impact Material: PVC Product Dimensions: 36" x 72" (O/X) Prepared For: JEL -WEN, Inc. 3737 Lakeport Blvd. Isla ath Falls, OR 97601 Prepared by: ,,%J%J11111//ii,,i Hermes F. Norero, P.E. ��� ��S F. Florida Professional Engineer # 73778 �`� Q- ..•••" F ��� Date: 08/11/2014 7 Contents: — Evaluation Report Pages 1 — 4 :moo. Cp oP.� 4- Digitally signed by Hermes F. Norero,��. FSS '•••••••'''�G\`'�`` Reason: I am approving this document ���pN; ; Date: 2014.09.1916:31:49 -04 00 Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub -Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung — Impact (Impact) 36" x 72" (0/X) Date: 08/11/2014 Report No: 3094 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3875-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3875-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Date: 0: 30 4 Report No: 94 A Perfect Solution in Every Drop Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: QUA 1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization # TST9341) Report #: NCTL-210-3875-1, Report Date: 4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization #: CER 1773) 3. Material Certification Miami Dade RER — Product Control Section NOA E.I. DuPont De Nemours & Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER — Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: Date: 08/11/2014 Report No: 3094 A. For concrete (Min. f'c = 3000 psi) or masonry substrate (Min. f c =1500 psi) where one by (1X), non-structural; wood bucking is employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min. f'c = 3000 psi) or masonry substrate (Min. f'c =1500 psi) where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use (1) #8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min. S.G. = 0.42) use (1) #10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3875-1-FBC) for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 65 PSF Negative 70 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI011567.04-R3 05/23/2013 Structural JELD-WEN 1822-1 01/13/2017 To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung (8100)" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls, OR 97601 (Fin or Flange Installation) Configuration: O/X Glazing: IG-1/8" Annealed Glass/Laminate- 1/8" Annealed Glass/0.090 "PVB Interlayer by DuPont/, 1/8" Annealed Glass or IG-1/8" Annealed Glass/Laminate- 1/8" annealedGlass/0.090" SentryGlas Plus by DuPont/ 1/8" Annealed Glass Frame: W-914mm(36") H-1829mm(72") Sash: W-845mm(33.25") H-883mm(34.75") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +65/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3875-1 Expiration Date: April 30, 2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fag: (804) 684-5122 5.5' MAX. FROM CORNERS 18' O.C. MAX. THRU NAIL FIN C s x #41 1 MAX. 4' FROM CORNERS IZ—WINDOW W1OTN (38' MAX.) TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use #10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" into the wood framing. For 2X wood frame substrate (min. S.G. = 0.42). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2014.09.1916:26:14-04'00' This schedule addresses only the fasteners required to anchor the >>111111 t,1 j. window to achieve the rated design pressure up to the size limitations ��� noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall ���.�Q` •.••''•• •.���i.. conditions. For the complete installation procedure, see the instructions i 'Z'; ; • : O packaged with the window or go to ,• 7 _ www.jeld-wen.com/resources/installation. -C DISCLAIMER: This drawing and its contents are confidential and are not to be 00 reproduced or copied in whole or in part or used or disclosed to others i1 except as authorized by JELD-WEN Inc. 398 E �/2MIN.ENT 2X WOOD FRAME MIN. DISTANCE FOR EDGE: 3/4" 1 1/4" MAX JSHIM SPACE Zzmm 2mm 3mm 3mm GLASS BITE 13. mm i i GLAZING DETAIL ® FRAME SECTION (TYP) VERTICAL SECTION 7 NOT:C kben— NeRl FkwaW Opmi 1/4" MAX SHIM SPACE 3 MIN. DISTANCE FOR EDGE: 3/4" L 2X WOOD FRAME EMBEDMENT MIN. DISTANCE FOR EDGE: 3/4" 2X WOOD FRAME 1 1/2" MIN. EMBEDMENT NAIL FIN INSTALLATION 1/4" MAX SHIM SPACE JAMB SECTION (TYP) HORIZONTAL SECTION NOTE: Coulk between Nailing Flange 6 Wood Opening. PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 36 x 72 1 +65/-70 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300, 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: DRAWN BY: D. Vezo CHECKED BY: J. Kantola r APPROVED BY: PART P0§7L9 to 388 IDENTIFIER No. NCTL210-3875- DATE` 3737 Lakeport Blvd 08/13/2014 SCALE: TELD-WN Klamath Falls, OR. 97601 TITLE: Premium Atlantic Vinyl Impact Single Hung Window DWG. No.: I REV: 00 ISHEET IOF3 �—{- MAX. FROM � I � CORNERS 15" D.C. MAX. THRU JAMB v IC 8 z e' MAX FROM CORNERS 1—WINDOW WIDTH (se' MAX) TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. Use 3/16" ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of 1 1/4" into concrete or masonry at each location with a 21/2" min from edge distance. For concrete (min. fc = 3000psi) or masonry substrate (CMU shall adhere to ASTM C90). 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resources/installation. _ 74 -n DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others �i� except as authorized by JELD-WEN Inc, 898 E! .• 7 MASONRY INSTALLATION 11/4° MIN. EMBEDMENT 3 1/4° MAX Q SHIM SPACE MIN. DISTANCE V V FOR EDGE: 2 1/2° C Q Q. .•o• V MASONRY BLOCK JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL SH WINDOW Max Frame DP RATING IMPACT 36 x 72 1 +65/-70 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. PROJECT ENGINEER: DATE: 3737 Lakeport Blvd 08/13/2014 JELD-WENKlamathDRAwN BY: scALE: Falls, OR. 97601 D. Vezo NTS I Phone: (541) 882-3451 CHECKED BY: J. Kantola APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window PIRUROI729 Ito 998 IDENTIFIER No. I PLANT NAME AND LOCATION: CAD DWG. No.: REV: SHEET NCTL210-3875- -FBC I 1 001 2 OF 3 5.5" MAX. FROM CORNERS 15" O.C. MAX. THRU JAMS ^v u i 6" MAX. FROM CORNERS 1---WINDOW WIDTH (36" MAX.) TYPICAL ELEVATION WITH FASTENER SPACING Installation Notes: 1. Seal flange/frame to substrate. 2. For anchoring into metal framing use #8 TEK Self Tapping screws with sufficient length to achieve a minimum embedment of three threads past the frame thickness. Steel substrate min.18ga., fy = 33 ksi. 3. Host structure (wood buck, masonry, steel) to be designed and anchored to properly transfer all loads to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does not address he sealing consideration that may arise in different wall conditions. For the complete installation procedure, see the instructions packaged with the window or go to www.jeld-wen.com/resources/installation. r DISCLAIMER: This drawing and its contents are confidential and are not to be reproduced or copied in whole or in part or used or disclosed to others except as authorized by JELD-WEN Inc. 398 s , — C 9Z jA , - * "*4 I FOR DISTANCE FOR EDGE: 1/2" Min. ;her of three threads past frame 18 gauge min Steel Stud MAX SHIM SPACE 22mm 2mm 3mm 3mm 6LA55 8ITE 13.6mm i i GLAZING DETAIL FRAME SECTION (TYP) VERTICAL SECTION NOTE: CoWk baxcsn Wlin Ff,g d Wnd Opma . 1/4" MAX SHIM SPACE 18 gauge min Steel Stud Min. embedment of three threads Past frame MIN. DISTANCE FOR EDGE: 1/2" 1,30D11OMQ,&I VA111IK/1IY[i"k7 18 gauge min Steel Stud 1/4" MAX SHIM SPACE MIN.DI5TANCE 2 FOR EDGE: 1/2" Min. embedment of three threads 3 past frame JAMB SECTION (TYP) HORIZONTAL SECTION PREMIUM ATLANTIC VINYL SH WINDOW Max Frame I DP RATING IMPACT 36 x 72 1 +65/-70 1 YES LARGE MISSILE IMPACT General Notes: 1. The product shown herein is designed, tested and manufactured to comply with the wind load criteria of the adopted International Building Code(IBC), the International Residential Code(IRC), the Florida Building Code (FBC) including HVHZ and the industry requirement for the stated conditions. 2. All glazing shall conform to ASTM E1300. 3. At minimum, glazing is 3mm annealed -11 mm airspace - 3mm annealed - 2mm PVB Interlayer by DuPont - 3mm annealed. 4. Use structural or composite shims where required. i �O PROJECr ENGINEER: DRAWN BY: D. Vezo ' 7 �. ;T* — CHECKED BY: J. Kantola >T Ty " 4tj O F ,' • 2sp�x5. � 398 i�t..asdo4 BY: PART PRO ECf o IDENTIFIER Na. NCTL210-38 DATE` 3737 Lakeport Blvd 08/13/2014 JELD�EN SCALE:Klamath Falls, OR. 97601 NTS I Phone: (541) 882-3451 TITLE: Premium Atlantic Vinyl Impact Single Hung Window AND LOCATION: I CAD DWG. No.: I REV. 00 I SHEET 3 OF 3