Loading...
HomeMy WebLinkAboutEnergy CodeK FORM R405-2020 FLORIDA ENERGY EFFICIENCY, CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -'Residential Performance Method Project Name: Lot 32 Phase 3 Waterstone 3000 AGL Builder Name:..ADAMS HOMES Street: 8337 Amalfi Circle Permit Office: City, State, Zip: Port Saint Lucie , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE CO_ INTL County: St. Lucie (Florida Climate Zone 2 ) 1; New construction or existing New (From Plans) 10.. Wall TypeP135.3 sgft.) Insulation Area 2. Single family or multiple family Detached a.. Concrete Block - Int Insul, Exterior R=4.1 1835.30 ft2 b. Frame - Wood, Adjacent R=13.0 300.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this worst case? No 1.1. Ceiling Types (3100.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 3000.00 ft2 6. Conditioned floor area above grade (ft2) 3000 b. Knee Wall (Vented) R=19.0 100.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7: Windows(309.8 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 600 a. U-Factor: Dbl, U=0.33 150.06 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 97.13 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a: Central Unit 47.5 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang.Depth: 1.499 ft. . 14Heating systems kBtu/hr Efficiency Area :Weighted Average SHGC: 0.282 a. Electric Heat Pump 45.5 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (3000.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft2 b. Conservation features . b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 78.37 Glass/Floor Area: 0.103 AS PASS 'Total Baseline Loads: 78.43 I hereby certify that the plans a ations covered b ReA f the plans and T 'ST,�rB this calculation are in complia a the FloridFiEFgy specifications covered by this O Code. calculation indicates compliance with the Florida Energy Code. f PREPARED BY: Before construction is completed DATE: n4-18-2021 Winn KPnmgny this building will be inspected for compliance with Section 553.908v. , I hereby certify that this building, as designed, is in compliance Florida Statutes: with the Florida Eme1gy Co coo�5. OWNER/AGENT• - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the. air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 4/16/2021 8:56 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 32 Phase 3 Waterstone 3 Bedrooms: 4 User Conditioned Area: 3000 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 32 Phase 3 Block/Subdivision: PSL - Bayshore PlatBook: Street: 8337 Amalfi Circle County: St. Lucie City, State, Zip: Port Saint Lucie , FL , 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Rang FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 3000 25500 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3000 25500 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 223.5 ft 0 3000 ft2 ---- 0.46 0 0.54 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 3354 ft' 750 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3000 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 3000 ft2 0.11 Wood 100 ft2 0.11 Wood 4/16/2021 8:56 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT '1 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 W Exterior Concrete Block - Int Insul Main 4.1 64 8 8 0 517.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Int Insul Main 4.1 65 0 8 0 520.0 ft2 0 0 0.6 0 3 E Exterior Concrete Block - Int Insul Main 4.1 49 0 8 0 392.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 50 9 8 0 406.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 30 0 10 0 300.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 18 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 0 in None None 2 S 2 Vinyl Low-E Double Yes 0.55 0.7 N 35.6 ft2 1 ft 4 in 1 ft 0 in None None 3 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 65.8 ft2 1 ft 4 in 1 ft 0 in None None 4 S 2 Vinyl Low-E Double Yes 0.3 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in None None 5 E 3 Vinyl Low-E Double Yes 0.33 0.23 N 19.5 ft2 1 ft 4 in 1 ft 0 in None None 6 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 64.8 ft2 1 ft 4 in 1 ft 0 in None None 7 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 4 in 1 ft 4 in None None 8 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 4 ft 3 in 1 ft 6 in None None 9 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 4 ft 4 in 1 ft 6 in None None 10 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 4 ft 4 in 3 ft 10 in None None 11 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 448 ft2 448 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000378 . 2975 163.22 306.42 .1294 7 4/16/2021 8:56 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 h r FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 45.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 47.5 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftz DUCTS. ---- Supply ---- I/ # Location R-Value Area ---- Return --- Location Area Leakage Type Air CFM 25 Handler TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 600 ftz Main 150 ftZ Proposed Qn Main --- cfm 150.0 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat: Y Cool in Jan Feb Mar Heating f X Jan H Feb Mar Ventin [ Jan Feb HX Mar Ceiling Fans: Jul Jun Jul Apr Ma X Jun rl Apr May I [X] Apr [ May Jun Jul Se AuSep Au ri rj Aug Se [X] Oct Oct Oct Nov XNov X Nov Dec Dec Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 .68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 4/16/2021 8:56 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 •FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 8337 Amalfi Circle,. Port Saint Lucie, FL, 34951 ' 1: New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.: Concrete Block = Int Insul, Exterior R=4.1 1835.30 ftz b. Frame - Wood, Adjacent R=13.0 300.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A Ft= ftz 1.1. Ceiling Type and insulation level Insulation Area 5: Is this a worst case? No a. Under Attic (Vented) R=30.0 3000.00 ftz 6. Conditioned floor area (ftz) 3000 b. Knee Wall (Vented) R=19.0 100.00 ftz 7. Windows- Description Area c. N/A R= ftz a. U-Factor: Dbl, U=0.33 150.06 ftz 12. Ducts, location & insulation. level R ftz a. Sup: Attic, Ret: Main, AH::Main 6 600 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=033 97.13 ftz SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ftz a. Central Unit 47.5 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 27.01 ftz SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.499 ft. a. Electric Heat Pump 45.5 HSPF:8.50 Area Weighted Average SHGC: 0.282 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ftz a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.94 b. Conservation features. 9. Floor Types Insulation • Area None a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ftz Credits (Performance method) Pstat b. N/A R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will b 'completed based on installed Code comoUant-features. Builder Signatu Date: Address of New Home: City/FL Zip: *Note: This is not a BuildingEnergy Rating. If our Index is below 70, our home may gy g. y y y qualify for energy efficient I (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/16/2021 8:56 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1