HomeMy WebLinkAboutProduct Approval (2) t-lontla building code Unllne
S Site Map Links Search c
=--^ -• — --'� VIEW
cations Contact Us BCI
BCIS Home Log In User Registration Hot Topics Sub t 9
CODE Cu"'MPLIANCE
I _ titer f=USER:PubIiAPProval STm CIE COUNTY
Product Approva I Menu>Frcduct pr Application Starch>Application List>Applio�Det-a �[ 1 �CJG
FL r# FL31963-R1
- Application Type Revision Jv QUnLy
Code Version 2020 �,V��O ttrr•r
Application Status
Approved
Comments
Archived
Product Manufacturer Beacon Sales Acquisitions,Inc. c/o Owens Corning Roofing and Asphalt LLC
Address/Phone/Email I Owens Corning Parkway
Toledo, OH 43657
(740) 587-3562
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA,Inc. -QA Entity
Quality Assurance Contract Expiration Date 12/31/2023
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL31963 R1 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D226 (physicals) 2009
ASTM D4533 (tear strength) 2015
ASTM D4798(weathering) 2011
ASTM D4869 (liquid transmission) 2016
ASTM D5035(tensile) 2011
Equivalence of Product Standards
Certified By
Sections from the Code
GwE18hURTXun4ztwP7Suj7zdiLde512CQ%3d%3d 1/2
https://ww .floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgs%2bxLlbWtJKV
w
/lti/LU21 Florida Building Code Online
r
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
`Date Approved 02/09/2021
Summary of Products
FL# Model, Number or Name c Description
---__ _ __-----_-_-
31963.1 i TRI-BUILT MAX Synthetic multi-layered,synthetic,sheet-type roofing underlayment
Underlayment
1 Limits of Use Installation Instructions
Approved)for use in HVHZ:Yes FL31963 Rl II 2620 12 1.6 FINAL ER BEACON-OC TRI-
Approved for use outside HVHZ:Yes BUILT MAX FL31963-RI.ndf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. :Evaluation Reports
i FL31963 Rl AE 2020 12 16 FINAL ER BEACON-OC TRI-
;BUILT MAX FL31963-Rl.pdf
Created by Independent Third Party: Yes
Contact Us::2601 Blair Stone Road,Tallahassee F32 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
Florida Statutes,effective.October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Departmentwith an email address which can be made available to the public.To determine if you area licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
C.redi,Card
Safe
https://www.floridabuifding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs%2bxLlbWtJKVGwEl8hURTXun4ztwP7Suj7zdiLde5l2CQ%3d%3d 2/2
NEMO I eft.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
ISO (203)262-9245
ENGINEER EVALUATE TEST CONSULT
Beacon Sales Acquisitions, Inc. Evaluation Report 3m-OC-20-FBCER.A-Rl
c/o Owens Corning Roofing and Asphalt, LLC FL31963-RI
One Owens Corning Parkway Date of Issuance:04/07/2020
Toledo,OH 43659 Revision 1:12/16/2020
(740)587-3562
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and,the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P,E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition(2020) Florida Building Code sections noted herein.
DESCRIPTION; TRP-BUILT®..MAX.Synthetic-Underlayment
LABELING: Labeling shall be.in. accordance with the requirements of the Accredited. Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
Robert J.M. Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCA ANE1983
;�1= ^L� Nieminen,P.E.on 12/16/2020.This does not serve as an
-:.�..,,,,,,:,:��
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 MEMO ETC,LLC
Emo etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT®MAX Synthetic Underlayment, as produced by Beacon Sales Acquisitions,
.Inc., has demonstrated compliance with the following sections of the 71' Edition (2020) Florida Building Code
through testing in accordance with applicable sections of the following Standards. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein,
Section Properties Standard Year
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tear strength ASTM D4533 2015
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 2011
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1518.4,RAS 115 Unrolling,Breaking Strength, ASTM D226 2009
Pliability
TAS 110 Accelerated Weathering ASTM D4798 2011
Entity Examination: Reference Date
PRI(TST5878) ASTM D4869 1378T0037 03/02/2020
PRI(TST5878) ASTM D226,ASTM.D4533,ASTM D4798 1378T0039 04/07/2020
PRI.(TST5878) ASTM D4533,ASTM D4798,ASTM D5035 1378TO113 10/15/2020
ITS(QUA1673) Quality Control Service Confirmation 04/07/2020
ITS(QUA1673) Quality Control Florida BCIS Current
Product `Material Standard Plants) Description
TRI-BUILT°MAX Synthetic 1507.1.1.1(2&3,Exception), Qingdao,China multi-layered synthetic sheet-type
Underlayment 1507.1.1.1(5)/ roofing underlayment;unit weight of
- R905.1.1.1(2&3,Exception), 3.9 Ibs/square
R905.1.1.1(5)
ASTM D226(physicals)
5.1- This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.3 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for
requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and
limitations concerning the use of foam plastic insulation.
5.4 TRI-BUILT® MAX Synthetic Underlayment may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority
Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
NEMO ETC,LLC Evaluation Report 3m-OC-20-FBCER.A-R1
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ AND HVHZ EVALUATION FL31963-RI
TRI-BUILT°MAX Synthetic Underlayment Revision 1:12/16/2020
Page 2 of 3
f
ONEMOJeM
5.5 Allowable Roof Covers:
TABLE 1: ROOF,COVER OPTIONS',
FBC NON-HVHZ: 1507.1 1507.3 1507.4&1507.5 2507.7 1507.8&1507.9
FBC HVHZ; TA5110(510),RA5115 TAS 110(511), RA5133- TAS110(S2I) RA5130
RAS 118,119&120
Clay and Concrete Slate or Slate-Type
Underlayment { Asphalt Shingles Metal Wood
f Tile . Shingles
TRI-BUILT"'MAX
NON-HVHZ: No
Synthetic Yes No Yes Yes
Underlayment HVHZ:.Yes
5.6 Exposure Limitations:
TABLE 2-..EXPOSURE LIMITATIONS.
Underlayment Maximum Exposure(days)
TRI-BUILT°MAX Synthetic Underlayment 180
6.1 TRI-BUILT° MAX Synthetic Underlayment shall be installed in accordance with the manufacturers published
installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris priorto application.
6.3_ TR1=6UILT°MAX Synthetic Underlayment:
6.3.1 I NON-HVHZ Jurisdictions:
6.3.1.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.3.1.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or
1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3.
6.3.2 HVHZ Jurisdictions:
6.3.2.1 Shall be installed in a shingle fashion with minimum 4-inch wide side(horizontal) laps and minimum 6-inch wide
end laps,and fastened in accordance with FBC HVHZ 1518.2.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
Refer to Section 4 herein for products and production locations having met codified material standards.
Intertek Testing Services NA Inc.—QUA1673; (312)906-7779; maura.norlander@intertek.com
END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 3m-OC-20-FBCER.A-RI
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ AND HVHZ EVALUATION FL31963-RI
TRI-BUILT°MAX Synthetic Underlayment Revision 1:12/16/2020
Page 3 of 3
FHe com,
EVALUATION REPORT OF a 0 (''v673
UNION CORRUGATING COMPAN
EE FOR
`26 GA. 5V PANEL' CODE COMPLIANCE
See LUPIE COUNTY
FLORIDA BUILDING CODE 7TH EDITION (2020)
FLORIDA PRODUCT APPROVAL
FL 20484.1-R2
ROOFING
METAL ROOFING
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville,NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report(3 Pages including cover)
Installation Details (1 Page)
Load Span Table (1 Page) �•��`rSGCKA L/I"v�`'ti
No 02240 1Y'
Report No. C2401-1 F
Date: 10.10.2020 �;��:' .�< O B�o.•�� ,`
t
•�"F332"
kQ a'So;
i'
' FL 20484.1-R2
C24011-1
10.10.2020
Page 2 of 3
Manufacturer: Union Corrugating Company J
Product Name: 5V Panel
Panel Description: 24" wide coverage with(5) 1/2" high ribs
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755). Corrosion resistant as per FBC 2020 Section 1507.4.3.
Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank
(min SG of 0.42) for new and existing constructions. Designed by
others and installed as per FBC 2020.
New Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1.
Required for new construction
Existing.Underlaymen : Onelayer.of asphalt-shingle!;..,over�:one layer of=#3'0<{fehTorxeroofmg
(Optional) construction only.
Slope: 1/2:12 or-greater in accordance with FBC 2020 Section 1507.4.2
Design Uplift Pressure: 71.0 psf at fastener spacing of 24" o.c.
(Factor of Safety=2) 169.0 psf at fastener spacing of 6" o.c.
Panel Attachment: #10-15 x 2" long wood screw with washer. Fasteners are corrosion
resistant as per FBC 2020 Section 1507.4.4.
At interior max 12" o.c. across panel width through panel rib
At panel ends max 6" o.c. across panel width through panel flat and rib
Minimum fastener length of 1.5" for new construction. For existing
construction, fastener shall be of sufficient length to penetrate through
the deck a minimum of 3/8".
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems'.
Test Equivalency: The test procedures in UL 1897-04 comply with test procedures
prescribed in UL 1897-12.
Code Compliance: The product described,herein has demonstrated compliance with FBC
2020 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
c
' FL 20484.1-R2
C2401-1
10.10.2020
Page 3 of 3
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer or based on Union load span table. This evaluation report is
not applicable in High Velocity Hurricane Zone. Refer to current NOA
for use of this product in High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2020 Section 1505 and current approved roofing materials
directory or ASTM E108/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents: UL580 &UL1897 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T197-16, Reporting Date 5/12/16