HomeMy WebLinkAboutAPPROVED A.C - LAYOUT - 8138 Saratoga -MELTON-GARAGE - CopyDUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINI MOM NO. 26.GAGE (0.48 mm) SHEET STEAL, I INCH. MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO -THE GARAGE, NOTES: .1. ALL HEATING, AIR CONDITIONING, -REFRIGERATION AND VENTILATION EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE FLORIDA BUILDING CODE MECHANICAL AND FLORIDA BUILDING CODE ENERGY CONSERVATION, 2, A 4' CLEARANCE IS TO BE MAINTAINED AROUND ALL AIR HANDLING UNITS, 3, PROVIDE FIRE DAMPERS AT SUPPLY AND RETURNS WHICH PASS THROUGH RATED ASSEMBLIES IF ANY. i 4. ALL DWELLING ROOMS MUST HAVE HVAC RETURNS, RETURNS MAY BE DUCTED, JUMPERS OR TRANSFER GRILLES, 5, A/C UNITS MAY HAVE CONC, PAD OR OTHER APPROVED MATERIAL EXTENDING ABOVE ADJOINING GRADE OR SHALL BE SUSPENDED A MIN, OF 6' ABOVE ADJOINING GRADE, PADS SHALL BE A MINIMUM 4' -0' X 4-6' PAD FOR UNIT, u * �4 1,D 00 0 t 0 0 > '--i F--i Ln _-q 0 ry 1 0 LL_ m I to crl' pq u O'� bJ --- Ln U-) Q 0 <Z I— co �00 w I— cu 00 M fl- 1,D co Lit Z 5, Woum 0 Z) u Z �OOJ < U F_� co pq m co 0- 0 MAY 28, 2019