Loading...
HomeMy WebLinkAboutAPPROVED Energy Calcs - 8138 Saratoga - Melton Garage 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 57/20/2021 12:42 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Melton Garage Melton Garage Street: City, State, Zip: Port St. Lucie , FL , 34986 8138 Saratoga Way Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 985 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.65 94.00 ft² SHGC=0.25 N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 985.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 910.00 ft² b. Frame - Wood, Adjacent R=11.0 490.00 ft² c. N/A R=f t ² 11. Ceiling Types a. Under Attic (Vented)R=30.0 985.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.000 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 16. Credits CF, Pstat 1 (94.0 sqft.) (1400.0 sqft.) (985.0 sqft.) (985.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 18.8 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 55 Tankless EF: 0.950 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.095 Total Proposed Modified Loads: Total Baseline Loads: 32.61 33.42 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 7-21-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County 1 Melton Garage Melton Garage Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 985 1 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34986 Port St. Lucie , St. Lucie 8138 Saratoga Way Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 985 9850 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Kitchen 271 2710 Yes 0 Yes Yes1 Yes 2 Family Room 252 2520 No 3 Yes Yes1 Yes 3 Master Bedroom 294 2940 No 2 1 Yes Yes1 Yes 4 Bath 105 1050 No 0 Yes Yes1 Yes 5 WIC 63 630 No 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 271 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -34 ft Kitchen 2 252 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -12 ft Family Room 3 294 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft Master Bedroom 4 105 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -22 ft Bath 5 63 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -9 ft WIC # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Barrel tile 1101 ft² Medium 0.6 0 26.57______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 985 ft² N N150 7/20/2021 12:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 30 271 ft² 0.1 Wood______ Kitchen Batt 2 Under Attic (Vented) 30 252 ft² 0.1 Wood______ Family Room Batt 3 Under Attic (Vented) 30 294 ft² 0.1 Wood______ Master Bedroom Batt 4 Under Attic (Vented) 30 105 ft² 0.1 Wood______ Bath Batt 5 Under Attic (Vented) 30 63 ft² 0.1 Wood______ WIC Batt WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0Kitchen 00021 10SW Concrete Block - Int Insul 0.50Exterior 210.0 ft² ____ 2 4.1 0Kitchen 00013 10NW Concrete Block - Int Insul 0.50Exterior 130.0 ft² ____ 3 4.1 0Family Room 00012 10NW Concrete Block - Int Insul 0.50Exterior 120.0 ft² ____ 4 4.1 0Master Bedro 00014 10NW Concrete Block - Int Insul 0.50Exterior 140.0 ft² ____ 5 4.1 0Bath 00015 10NE Concrete Block - Int Insul 0.50Exterior 150.0 ft² ____ 6 4.1 0Bath 0007 10NW Concrete Block - Int Insul 0.50Exterior 70.0 ft² ____ 7 4.1 0WIC 0009 10NE Concrete Block - Int Insul 0.50Exterior 90.0 ft² ____ 8 11 0Kitchen 13 10SE Frame - Wood 0.50.23Garage 130.0 ft² ____ 9 11 0Family Room 12 10SE Frame - Wood 0.50.23Garage 120.0 ft² ____ 10 11 0Master Bedro 14 10SE Frame - Wood 0.50.23Garage 140.0 ft² ____ 11 11 0WIC 7 10SE Frame - Wood 0.50.23Garage 70.0 ft² ____ 12 11 0WIC 3 10SW Frame - Wood 0.50.23Garage 30.0 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 24 ft² None______ SE Family Room 83 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 SW Low-E Single 0.65 0.25 16.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes1 Y 2 NW Low-E Single 0.65 0.25 48.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes3 Y 3 NW Low-E Single 0.65 0.25 30.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______ Yes4 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 2070 ft² 2070 ft² 49 ft 10 ft 11______ 7/20/2021 12:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 985 654.04.000381Wholehouse .1184101.45Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 17 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 16 18.8 kBtu/hr c f m 0.7______ sys#1Split 1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 1 gal 60.9 gal 120 deg None______ Tankless Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 55 ft² Attic 15 ft² Default Leakage Garage ( D e f a u l t ) ______ 1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting 7/20/2021 12:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Kitchen Default(8 lbs/sq.ft. f t ² f t 0.3 Family Room Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom Default(8 lbs/sq.ft. f t ² f t 0.3 Bath Default(8 lbs/sq.ft. f t ² f t 0.3 WIC 7/20/2021 12:42 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie County Melton Garage Melton Garage Street: City, State, Zip: Port St. Lucie , FL , 34986 8138 Saratoga Way Permit Number: Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software7/20/2021 12:42 PM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a 8138 Saratoga Way, Port St. Lucie, FL, 34986 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 1 No 985 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 94.00 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 985.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Int Insul, Exterior R=4.1 910.00 ft² b. Frame - Wood, Adjacent R=11.0 490.00 ft² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Under Attic (Vented) R=30.0 985.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 1 gallons EF: 0.95 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method) CF, Pstat Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 1.000 ft. 0.250 a. Electric Strip Heat 17.0 COP:1.00 a. Central Unit 18.8 SEER:16.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: Garage 6 55 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 7/20/2021 12:42 PM