HomeMy WebLinkAboutAPPROVED Health Department - 8138 Saratoga Way guest house garage additionSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR:
APPLICANT: Rrvant MPitnn
OSTDS New
PROPERTY ADDRESS: 8138 Saratoga Way Port Saint Lucie, FL 34986
LOT: 85 BLOCK:
PROPERTY ID # : 3i2 i 5n2nn,�4nnn:i
SUBDIVISION: SahM C;rPPk II
PERMIT #:56-SF-2165733
APPLICATION # : AP 1577560
DATE PAID:
FEE PAID:
RECEIPT #:
DOCUMENT # : PR1410401
[SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [ 900 ] GALLONS / GPD Sectic new CAPACITY
A [ ] GALLONS / GPD N/A CAPACITY
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ]
D [ 334 ] SQUARE FEET Drainfield new
R [ ] SQUARE FEET
A TYPE SYSTEM: [ ] STANDARD
I CONFIGURATION: [ ] TRENCH
N
F LOCATION OF BENCHMARK: Site BM PK/Disk "SSMC TRAY" ELEV = 23.29 NAVD 1988
I ELEVATION OF PROPOSED SYSTEM SITE
E BOTTOM OF DRAINFIELD TO BE
L
D I
O
T
H
E
R
N/A
SYSTEM
SYSTEM
[ ] FILLED [x] MOUND [ ]
[x] BED [ ]
[ 9.00 ][ INCHES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT
[ 20.00 ] [ INCHES FT I[ BELOW ]BENCHMARK/REFERENCE POINT
'11,L REQUIRED: [ Ly.UUJ INCHES EXCAVATION REQUIRED: [ J INCHES
The system is sized for 1 bedrooms with a maximum occupancy of 2 persons (2 per bedroom), for a total estimated flow of
200 gpd.
SPECIFICATIONS BY: Brian J In Ham TITLE: Environmental Specialist II
f
APPROVED BY: TITLE: Environmental Specialist II
Brian J Igi-r_
DATE ISSUED: 09/29/20201/ EXPIRATION DATE:
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
v 1.1.4 AP1577560 SE1368840
St. Lucie CHD
03/29/2022
Page 1 of 3
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency
Clerk's facsimile number is 850-413-8743.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a 'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a
second copy, accompanied by the filing fees required by law, with the Court of Appeal in the
appropriate District Court. The notice must be filed within 30 days of rendition of the final order.
St. Lucie County Health Department
5150 NW Milner Dr Port Saint Lucie, FL 34983
PAYING ON: #: 56-SF-2165733 BILL DOC #:56-BID-4983393 CONSTRUCTION APPLICATION #: AP1577560
RECEIVED FROM: Alexander Piazza AMOUNT PAID: $ 545.00
PAYMENT FORM: CREDIT CARD 07362C PAYMENT DATE: 09/10/2020
MAIL TO: Bryant Melton
�j AAA w Jy�
FACILITY NAME:
PROPERTY LOCATION:
8138 Saratoga Way
Port Saint Lucie, FL 34986
85
Lot: Block:
Property ID: 332150200340003
EXPLANATION or DESCRIPTION:
QUANTITY
FEE
128 - OSTDS Construction System Inspection Research Fee
1
$
5.00
-1 - Surcharge (All)
1
$
45.00
-1 - OSTDS New Permit Surcharge
1
$
100.00
-1 - OSTDS Construction Application and Plan Review,New
1
$
100.00
123 - OSTDS Construction Site Evaluation
1
$
115.00
126 - OSTDS Construction Permit (New or Mod, Amendment)
1
$
55.00
127 - OSTDS Construction System Inspection
1
$
75.00
133 - OSTDS Construction Reinspection
1
$
50.00
RECEIVED BY: EvansJS AUDIT CONTROL NO. 56-PID-4661124
,r'dFmm 4
mm
STATE OF FLORIDA
DEPARTMENT OF HEALTH
4 L= ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
New System [ ] Existing System [ ] Holding Tank
[ ] Repair [ ] Abandonment [ ] Temporary
APPLICANT:
AGENT:
MAILING ADDRESS:
Bryant & Laura Melton
PERMIT NO. S� - eA / �33
DATE PAID: qllolso
FEE PAID: 546: 09
RECEIPT # : C-6 - 0 !; l3&-./'
[ ] Innovative
[ l
Alexander J. Piazza PSM, Inc. TELEPHONE:
61.9 SW Biltnlore Street, Port St. Lucie, Florida 34983
772-340-7770
------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: 85 BLOCK: - SUBDIVISION: Sabel Creek Phase 2 PLATTED: 1984
PROPERTY ID # : 3321-502-0034-000-3 ZONING: R I /M OR EQUIVALENT: [ No ]
PROPERTY SIZE: 1.888 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [,v]<=2000GPD [ 1>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT
PROPERTY ADDRESS: 8138 Saratoga Way, Port St. Lucie, Florida 34986
DIRECTIONS TO PROPERTY: SEE MAP
BUILDING INFORMATION [V ] RESIDENTIAL [ ] COMMERCIAL
Unit Type of No. of Building Commercial/Institutional System Design
No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC
1 RESIDENCE 1 985
2
3
4
[ ] Floor/Equipment Drains [ ,/ ] Other (Specify) GARBAGE GRINDERS / DISPOSALS
Digitally signed by Almnd,r 1 Piai>n
Alexander J Piazza DK:c=GS,o=lJnafiiliaicd.rnL=A01d10DOOOOO172i(,C221'43000167['A, cn=A1—,nt<r.1
SIGNATURE: Dac 2020.0931 VJA2.36-(4J'OlP DATE: 8-3 1-20
DH 4015, 08/09 (Obsoletes previous editions which may not be used)
Incorporated 64E-6.001, FAC Page 1 of 4
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION
APPLICANT: Bryant Melton
CONTRACTOR / AGENT:
LOT: 85
Alexander Piazza
BLOCK:
SUBDIVISION: SabalCreek ll ID#: 332150200340003
APPLICATION # AP'1577560
PERMIT # 56-SF-2165733
DOCUMENT # SF1'�FRRdn
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 1.89 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 200 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 4724.98 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 2000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 500.00 SQFT
BENCHMARK/REFERENCE POINT LOCATION: Site BM PK/Disk "SSMC TRAY" ELEV = 23.29 NAVD 1988
ELEVATION OF PROPOSED SYSTEM SITE 9.00 [ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [X]NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: 100 FT
BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 72 FT POTABLE WATER LINES: 14 FT
SITE SUBJECT TO FREQUENT FLOODING?
10 YEAR FLOOD ELEVATION FOR SITE:
SOIL PROFILE INFORMATION SITE 1
USDA SOIL SERIES:
Munsell #/Color
Texture
1 OYR 4/2
Organic Soil
1OYR 5/3
Sand
1OYR 5/1
Sand
1 OYR 6/1
Sand
1 OYR 4/4
Sand
10YR 5/3
Sand
HOLE CAVING
Refusal
[ ] YES [ X ] NO 10 YEAR FLOODING? [ ] YES [ X ] NO]
FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD
De pth
0To5
5To9
9 To 27
13 To 27
27 To 36
36 To 40
40 To 72
SOIL PROFILE INFORMATION SITE 2
USDA SOIL SERIES:
Munsell #/Color
Texture
Depth
10YR 3/2
Organic Soil
0 To 7
10YR 5/2
Sand
7 To 10
10YR 5/1
Sand
10 To 25
1 OYR 6/1
Sand
15 To 33
10YR 4/3
Sand
33 To 36
1 OYR 5/3
Sand
36 To 43
HOLE CAVING
Refusal
43 To 72
OBSERVED WATER TABLE: 5.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ]
ESTIMATED WET SEASON WATER TABLE ELEVATION: 13 INCHES [ ABOVE / BELOW ] EXISTING GRADE
HIGH WATER TABLE VEGETATION: [ ]YES [X ]NO MOTTLING: [X]YES [ ]NO DEPTH: 13.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [ ] TRENCH [X ] BED [ ] OTHER (SPECIFY)
- REMARKS/ADDITIONAL CRITERIA
WSWT determined using USDA WSS and soil borings.
10YR6/1 stripping in 10YR5/1 matrix >10% with diffuse boundaries starting at 13" in S131.
SB1 9" above BM. S62 10" above BM. A;'
SITE EVALUATED BY:
Ingram, BrianPitle: Environmental Specialist II) (ENVIRONMENTAL HEALTH)
DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC
DATE: 09/24/2020
Page 3 of 4
AP1577560 EID2165733 v 1.0.2
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATIONS
PERMIT #.
APPLICANT: Bryant & Laura Melton AGENT: Alexander J. Piazza PSM, Inc.
LOT: 85 BLOCK: - SUBDIVISION: Sabel Creek Phase 2
PROPERTY ID # : 3321-502-0034-000-3 [ Tax ID Number
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS
MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS.
PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 1.888 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 333 GALLONS PER DAY [RESIDENCES -TABLE I/OTPTER-TA.BLE2 ]
AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 500 SQFT UNOBSTRUCTED AREA REQUIRED: 500 SQFT
BENCHMARK/REFERENCE POINT LOCATION:
ELEVATION OF PROPOSED SYSTEM SITE IS34
[ INCHES / FT ] [ ABOVE / BELOW ] BENCHMARK/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER:100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ I YES [v/] NO
WELLS: PUBLIC: 200 FT LIMITED USE : 100 FT PRIVATE: 75 FT NON —POTABLE: 100 FT
BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT
SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES [v/] NO
10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD
SOIL PROFILE INFORMATION SITE 1
MUNSELL #/COLOR TEXTURE DEPTH
TO
TO
TO
TO
TO
TO
TO
TO
TO
USDA SOIL SERIES:
SOIL PROFILE INFORMATION SITE 2
MUNSELL #/COLOR TEXTURE DEPTH
TO
TO
TO
TO
TO
TO
TO
TO
TO
USDA SOIL SERIES:
OBSERVED WATER TABLE : 40+ INCHES [ BELOW r] EXISTING GRADE. TYPE: [PERCHED/ APPARENT ]
'sSTIMATED WET SEASON WATER TABLE ELEVATION: INCHES ABOVE BELOW ] EXISTING GRADE
1IGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ ] YES [ ] NO DEPTH: INCHES
TOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING:
)RAINFIELD CONFIGURATION: [✓] TRENCH [ ] BED
tEMARKS/ADDITIONAL CRITERIA:
DEPTH OF EXCAVATION:
[ ] OTHER (SPECIFY)
INCHES
igi airy signea uy a exander Piazza
Alexander Piazza
DN US,o=Unaffilinted,au=F101A10D00000172 i6C22F43000767FFl,
SITE EVALUATED BY : L Q `°-:2020.e Piazza
DATE: 8-31-20
Date: 2020.OP,.31 09:42:26-04'00'
H 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC
Page 3 of 4
APPLICANT'S NAYIE:
Bryant & Laura Melton
LEGAL DESCRIPTION: Lot 85 of Sable Creek Phase 2 (PB 24, PG 1, PGS 1 A-1 C)
PROPOSED ► EPI SY�?'�'1� RY FV KJ f HOX
I certify that there are no potable private wells within 75 feet of the available area for the
proposed septic system, that there are no non -potable wells within 50 feet of the available area
for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated
building foundation, that there are no public wells that serve less than 25 people or less than
15 homes or businesses within 100 feet of the proposed septic system, that there are no public
wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of
the proposed septic system, that the water line from the water meter or well to the structure is
at least 10 feet from the available area for the proposed septic system unless the plans show
the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or
vacuum sewage line in a public easement or right-of-way that, abuts the property, that there
are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the
proposed septic system unless the property was created prior to 1972, that the septic system is
proposed on the side of the lot farthest from surface water, that all private wells, septic
systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot
are shown on the site plan, that all public wells within 200 feet of the applicant's lot are
shown on the site plan, and that the location of building or residences, swimming pools,
recorded easements, paved areas or driveways, sidewalks, the general slope of the property,
filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or
wetlands are shown on the applicants lot.
The natural grade elevation in the area of the proposed septic system and the benchmark must
be shown on the site plan. Please. locate the benchmark within 200 feet of the proposed septic
system.
NOTE: MUST BE CERTIFIED BY A FLORIDA
REGISTERED SURVEYOR OR ENGINEER.
Digitally signed by Alexander) Piazza
Alexander J Piazza ou=AM4i0D00000in bc22ra3nooiezrA,
cn=Alexander 1 Piazza
CERTIFIED BY: Date: 2020.08.31 09:42:17 -04'00'
FLORIDA PROFESSIONAL NO.: 6330
DATE: 08/31 /20 JOB NO.: 19-4733
docs/torms/septics/Sep tic ApppPageZ07
Custom Soil Resource Report
St. Lucie County, Florida
37--Riviera sand, frequently ponded, 0 to 1 percent slopes
Map Unit Setting
National map unit symbol: 2tzwm
Elevation: 0 to 70 feet
Mean annual precipitation: 46 to 58 inches
Mean annual air temperature: 68 to 77 degrees F
Frost -free period., 350 to 365 days
Farmland classification: Farmland of unique importance
Map Unit Composition
Riviera and similar soils: 85 percent
Minor components: 15 percent
Estimates are based on observations, descriptions, and transects of the mapunit.
Description of Riviera
Setting
Landform: Depressions on marine terraces
Landform position (three-dimensional): Tread, dip
Down -slope shape: Concave
Across -slope shape: Concave
Parent material: Sandy and loamy marine deposits
Typical profile
A - 0 to 0 inches: sand
E - 0 to 22 inches: sand
Btg/E - 22 to 31 inches: sandy loam
Btgl - 31 to 42 inches: sandy loam
Btg2 - 42 to 80 inches: sandy clay loam
Properties and qualities
Slope: 0 to 1 percent
Depth to restrictive feature: More than 80 inches
Drainage class: Very poorly drained
Runoff class: Negligible
Capacity of the most limiting layer to transmit water (Ksat): Moderately low to
moderately high (0.06 to 0.20 in/hr)
Depth to water table: About 0 inches
Frequency of flooding: None
Frequency of ponding: Frequent
Calcium carbonate, maximum content: 4 percent
Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm)
Sodium adsorption ratio, maximum: 4.0
Available water capacity: Moderate (about 6.7 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 7w
Hydrologic Soil Group: C/D
Forage suitability group: Sandy over loamy soils on stream terraces, flood plains,
or in depressions (G155XB245FL)
10
Custom Soil Resource Report
Other vegetative classification: Freshwater Marshes and Ponds (R155XY010FL),
Sandy over loamy soils on stream terraces, flood plains, or in depressions
(G155XB245FL)
Hydric soil rating: Yes
Minor Components
Chobee
Percent of map unit: 5 percent
Landform: Depressions on marine terraces
Landform position (three-dimensional): Tread, dip
Down -slope shape: Concave
Across -slope shape: Concave
Ecological site: R155XY010FL - Freshwater Marshes and Ponds
Other vegetative classification: Freshwater Marshes and Ponds (R155XY010FL),
Loamy and clayey soils on stream terraces, flood plains, or in depressions
(G155XB345FL)
Hydric soil rating: Yes
Wabasso
Percent of map unit: 4 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy
soils on flats of mesic or hydric lowlands (G155XB141 FL)
Hydric soil rating: No
Malabar
Percent of map unit., 3 percent
Landform: Depressions on marine terraces
Landform position (three-dimensional): Tread, dip
Down -slope shape: Concave, linear
Across -slope shape: Concave, linear
Ecological site: R155XYO11 FL - Slough
Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy
soils on flats of mesic or hydric lowlands (G155XB141 FL)
Hydric soil rating: Yes
Hallandale
Percent of map unit: 3 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R 1 55XY003FL), Sandy
soils on flats of mesic or hydric lowlands (G155XB141 FL)
Hydric soil rating: Yes
11
Custom Soil Resource Report
48—Wabasso sand, 0 to 2 percent slopes
Map Unit Setting
National map unit symbol: 2svyr
Elevation: 0 to 70 feet
Mean annual precipitation: 46 to 55 inches
Mean annual air temperature: 70 to 77 degrees F
Frost -free period: 355 to 365 days
Farmland classification: Farmland of unique importance
Map Unit Composition
Wabasso and similar soils: 85 percent
Minor components: 15 percent
Estimates are based on observations, descriptions, and transects of the mapunit.
Description of Wabasso
Setting
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Parent material: Sandy and loamy marine deposits
Typical profile
A - 0 to 6 inches: sand
E - 6 to 25 inches: sand
Bh - 25 to 30 inches: sand
Btg - 30 to 58 inches: sandy clay loam
Cg - 58 to 80 inches: loamy sand
Properties and qualities
Slope: 0 to 2 percent
Depth to restrictive feature: 9 to 50 inches to strongly contrasting textural
stratification
Drainage class: Poorly drained
Runoff class: Very high
Capacity of the most limiting layer to transmit water (Ksat): Moderately low to
moderately high (0.06 to 0.20 in/hr)
Depth to water table: About 6 to 18 inches
Frequency of flooding: None
Frequency of ponding: None
Calcium carbonate, maximum content: 5 percent
Maximum salinity: Nonsaline to very slightly saline (0.0 to 2.0 mmhos/cm)
Sodium adsorption ratio, maximum: 4.0
Available water capacity.- Very low (about 1.4 inches)
Interpretive groups
Land capability classification (irrigated): None specified
Land capability classification (nonirrigated): 3w
12
Custom Soil Resource Report
Hydrologic Soil Group: C/D
Forage suitability group: Sandy soils on flats of mesic or hydric lowlands
(G155XB141 FL)
Other vegetative classification: South Florida Flatwoods (R 1 55XY003FL), Sandy
soils on flats of mesic or hydric lowlands (G155XB141 FL)
Hydric soil rating: No
Minor Components
Hallandale
Percent of map unit. 6 percent
Landform: Flatwoods on marine terraces
Landform position (three-dimensional): Tread, talf
Down -slope shape: Linear
Across -slope shape: Linear
Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy
soils on flats of mesic or hydric lowlands (G155XB141 FL)
Hydric soil rating: Yes
Boca
Percent of map unit: 5 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, talf
Down -slope shape: Linear, convex
Across -slope shape: Linear, concave
Ecological site: R155XY003FL - South Florida Flatwoods
Other vegetative classification: South Florida Flatwoods (R155XY003FL), Sandy
over loamy soils on flats of hydric or mesic lowlands (G155XB241 FL)
Hydric soil rating: Yes
Pineda
Percent of map unit: 4 percent
Landform: Drainageways on marine terraces, flats on marine terraces
Landform position (three-dimensional): Tread, dip, talf
Down -slope shape: Linear
Across -slope shape: Linear, concave
Other vegetative classification: Slough (R155XY011 FL), Sandy over loamy soils
on fiats of hydric or mesic lowlands (G155XB241 FL)
Hydric soil rating: Yes
13