Loading...
HomeMy WebLinkAboutAPPROVED Survey - Health Department ApprovalQ gyp. M11;.1=1T1_�i1f (__ = GUY WIRE ANCHOR = CABLE TELEVISION BOX ❑ = CATCH BASIN = CATCH BASIN INLET = CLEANOUT © = ELECTRIC BOX [D = TELEPHONE BOX a = SIGN = SANITARY MANHOLE = STORM MANHOLE 5 = NUMBER OF PARKING SPACES J = FIRE HYDRANT = LIGHT POLE = CONCRETE POWER POLE ® = BACKFLOW PREVENTOR ® = MAIL BOX = IRRIGATION VALVE = GAS VALVE = SEWER VALVE w = WATER VALVE ® = WELL ® = WATER METER 1A = WOOD POWER POLE Q = SET 5/8" IRON ROD WITH PLAS CAP PSM#6330 I_T=1=I T*Pj[Xff$M% (C) = CALCULATED CBS = CONCRETE BLOCK STRUCTURE CMB = COMMISSIONERS' MINUTES Bt CONC = CONCRETE CLF = CHAIN LINK FENCE (D) = DEED DE = DRAINAGE EASEMENT DEP = DEPARTMENT OF ENVIRONMENT DB = DEED BOOK FFE = FINISHED FLOOR ELEVATION FND = FOUND FPL = FLORIDA POWER & LIGHT INV = INVERT IP = 3/4" IRON PIPE IR = 5/8" IRON REBAR IRC = IRON ROD WITH PLASTIC CAF LB = LICENSE BUSINESS LS = LICENSE SURVEY (M) = MEASURED MON = MONUMENT ORB = OFFICIAL RECORD BOOK (P) = PLAT PS = PLAT BOOK PG = PAGE PCOR = PROPERTY CORNER PL = PROPERTY LINE POB = POINT OF BEGINNING POC = POINT OF COMMENCEMENT PRM = PERMANENT REFERENCE MONUMENT R/W = RIGHT-OF-WAY RCP = REINFORCED CONCRETE PIPE RGE = RANGE SEC = SECTION TWP = TOWNSHIP UE = UTILITY EASEMENT PUDE = PUBLIC UTITLITY & DRAINAGE EASEMENT R = RADIUS OF CURVE L = LENGTH OF CURVE 0 = DELTA OF CURVE I`I • Mi111111121110 ' RESERVE BLVD W I- w to a W f-- Z LEGAL DESCRIPTION: LOT 85 OF SABLE CREEK PHASE It, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 24, PAGE 1, PAGES 1A THROUGH 1C, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 82,250 SQUARE FEET OR 1.888 ACRES, MORE OR LESS. FDOH in St. Lucie County Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for OSTDS #%-SF ,Zf&:5733 & Well # Date: 9/� Reviewer:% � -- SURVEY REPORT: 1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER 5J-17.050(11}, FLORIDA ADMINISTRATIVE CODE. 2. SURVEY BASED ON THE PLAT OF SABLE CREEK PHASE II AS RECORDED IN PLAT BOOK 24, PAGE 1, PAGES 1A THROUGH 1C, OF THE PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA. 3. LEGAL DESCRIPTION WAS FURNISHED BY CLIENT. PAS° 4, BEARING BASIS: A "GRID NORTH" BEARING OF S46°25'51"E ALONG CENTERLINE OF SARATOGA WAY OF ? SAID PLAT OF SABLE CREEK PHASE H . 5. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 6. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY q PANEL NO. 12111CO254 J, EFFECTIVE DATE 2-16-12. yS 7. FLOOD ZONE SHOWN HEREON IS ANINTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 8. THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY. NO SEARCH OF THE PUBLIC RECORDS HAS BEEN PERFORMED BY ALEXANDER J. PIAllA PSM, INC. 9. THE EXPECTED USE OF THE SUBJECT PROPERTY IS FOR THE CONSTRUCTION OF A SINGLE FAMILY DETACHED BUILDING AND FALLS WITHIN THE SUBURBAN CATEGORY AS CLASSIFIED IN CHAPTER 5J-17.051(2), FLORIDA ADMINISTRATIVE CODE. ALL FIELD -MEASURED CONTROL MEASUREMENTS EXCEEDED 1:7,500 FEET ACCURACY REQUIREMENTS FOR THIS CLASSIFICATION. ALL SURVEY MEASUREMENTS ARE IN ACCORDANCE WITH THE UNITED STATES STANDARD IN FEET. Surveying MappingConsulting R Port St. Lucie, Florida 34983 PROPOSEDADD '" • . • i LW2C�lli� t r 10. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF ALEXANDER J. PIAZZA PSM, INC. 11. SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 12. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 13. THE BEARINGS SHOWN HEREON ARE RELATIVE TO THE STATE PLANE COORDINATE SYSTEM OF THE NORTH AMERICAN DATUM OF 1983 (2007 ADJUSTMENT) AND THE ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 AND ARE REFERENCED TO THE LENGEMANN OF FLORIDA'S L-NET GPS NETWORK DEVELOPED WHICH MEETS OR EXCEEDS THE FEDERAL GEODETIC CONTROL COMMITTEE (FGCC) GUIDELINES FOR "GEOMETRIC GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING GPS RELATIVE POSITIONING TECHNIQUES" AS WELL AS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF LAND SURVEYORS IN CHAPTER 5J-17.051 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO CHAPTER 472.027 FLORIDA STATUTES. BENCHMARKS SET OR FOUND FOR THIS SURVEY ARE NOTED ON THE SKETCH. 14. THIS SURVEY IS PREPARED ONLY FOR THE PARTIES LISTED BELOW AND IS NOT ASSIGNABLE. CERTIFIED TO: BRYANT & LAURA MELTON 15. c COPYRIGHT 2020 BY ALEXANDER J. PIAZZA PSM, INC. HE SKETCH OF SURVEY AND SURVEY REPORT COMPRISE THE COMPLETE SURVEY. THIS SURVEY IS NOT VALID UNLESS THE SKETCH AND REPORT ACCOMPANY EACH OTHER. REPRODUCTIONS OF THIS SURVEY ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER EMPLOYED BY ALEXANDER J. PIAZZA PSM, INC. ALEXANDER J. PIAZZA PSM, INC. �a�1s�s 8-15-9 9v, I��>. DATE OF FIELD SURVEY: 5-13-08 12W, DATE OF SURVEY: 5-14-08 BOUNDARY SURVET 8SARATOGA WAY SEC 28, * # PREPAREDAS • BRYANT•LAURA.' PROFES 4ONAL WRVEYOR �NIQ MAPPER FLORID,*,CE'RTIh' ATE N i 330 q4"'Sfr. CAD K:\BUILDERS\DWG2019\19-4733.1bii T3�mO11w0,V" REF K:\BUILDERS\DWG2008\DWG\08-402.DWG FLD AJP FB. PG. JOB 19-4733 OFF AJP DATE 8-19-19 CKD AJP SHEET 1 OF 1 DWG D-0881