Loading...
HomeMy WebLinkAboutAPPROVED, Fire Rating and UL(1)CONCRETE STRUCTURE —� PROVIDE FIRE CAULKING AT ALL ---- - 1 HOUR WALL PENETRATIONS CEILING - SEE FINISH A SCHEDULE 5/8" TYPE X GYP. BD. OVER 3-1/2" METAL STUDS ® 16" O.C. 3-1/2" SOUND ATTENUATION INSULATION SEE FINISH SCHEDULE FOR BASE FLOOR TRACK - SECURE TO FLOOR SLAB ® 24" O.C. WITH POWER ACTIVATED DRIVE PIN }" PERIMETER RELIEF WITH CONTINUOUS ACOUSTICAL SEALANT EXISTING CONCRETE SLAB - SEE FINISH SCHEDULE FOR FLOORING 1 HOUR FIRE RATED METAL STUD PARTITION 5/8" TYPE X GYPSUM BOARD ON BOTH SIDES OF METAL STUD FRAMING PARTITIONS REQUIRING SOUND RATING TO HAVE 3" MINERAL FIBER SOUND ATTENUATION BLANKETS BETWEEN STUDS AND ACOUSTICAL SEALANT AT PERIMETER AND OPENINGS 1 N R WALL. SECTION - U L463 N TS CONCRETE STRUCTURE -- PROVIDE FIRE CAULKING AT ALL -- 2 HOUR WALL PENETRATIONS CEILING - SEE FINISH SCHEDULE 2 - 5/8" TYPE X GYP. BD. OVER 3-1/2" METAL SPUDS 16" O.C. 3-1/2" SOUND ATTENUATION INSULATION SEE FINISH SCHEDULE FOR. / BASE FLOOR TRACK - SECURE TO FLOOR SLAB 0 24" O.0 WITH POWER ACTIVATED DRIVE PIN I" PERIMETER RELIEF WITH CONTINUOUS ACOUSTICAL SEALANT EXISTING CONCRETE SLAB - SEE FINISH SCHEDULE FOR FLOORING 2 HOUR FIRE RATED METAL STUD PARTITION 5/8" TYPE X GYPSUM_BOARD ON BOTH SIDES OF METAL STUD FRAMING PARTITIONS REQUIRING SOUND RATING TO HAVE 3" MINERAL FIBER SOUND ATTENUATION BLANKETS BETWEEN STUDS AND ACOUSTICAL SEALANT AT PERIMETER AND OPENINGS 2N R WALL SECTION - U L419 N TS u� w <� 0- Z) U � 10 m 0 =) Z d O a U ® o w N v w Q Z iw- m L� a 3 w m LLJZ m Don SEAL U =)V) Q� o MQwoc HO< Otn J � Qo�c, �o I w G.R.G. OIEP6D dS.B. w.n 7-5-21 AS SHOWN ,roe un