Loading...
HomeMy WebLinkAboutAPPROVED, jb_349336_00___acad_b_01 SINDEX ABBREVIATIONS VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A OES 9/7/2021 Structural stamp was added, Backup switch removed, **** **** **** **** LICENSE GENERAL NOTES ELECTRICAL NOTESELECTRICAL NOTES • ” • ” • ” • • (E) DRIVEWAY Front Of House Pitch 3/12 MP1Pitch0/12MP2 Pitch3/12MP3Pitch3/12MP4Pitch3/12MP5Scale: 3/32" = 1' SITE PLAN 0 1'10'21' LEGEND MP1 14 270 14 270 Solar Roof Two MP3 14 90 14 90 Solar Roof Two LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS AC Z GNDGND Y 16 N EGC L2 L115 W 14 L1NEGCL2 POI Z Y X W 15 16 14 A L2 L1 N EGC GND N 240V240V240V240V Product 1 EGC DC- DC+ DC- DC+ DC- DC+ B C A DC- DC+ DC- DC+ DC- DC+ DC- DC+ DC- DC+ DC- DC+ GD MP 1: 2x24 MP 1: 2x24 MP 3: 2x38 GD A PV B C 1 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC3 4 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC4 5 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC5 6 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC6 7 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC7 8 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC8 9 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC9 10 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC10 11 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC11 12 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC12 13 Vmp = VAC Imp= AAC 13 12V X LICENSEMODULE SPECS 1 PRODUCT SPECSGENERAL NOTESMAIN PANEL SPECSGROUND SPECS 2 3 AC DC SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set BACKUP LOAD CENTERLabel Location:Backup Load Center Per Code: NEC 408.4Label Location:Backup Load Center Per Code: NEC 220Label Location:Main Panel Per Code: NEC 312.8(3) STORAGE SYSTEM LABELSCAUTIONDO NOT ADD NEW LOADSCAUTIONTHIS PANEL HAS SPLICED FEED-THROUGH CONDUCTORS. LOCATION OF DISCONNECT AT ENERGY STORAGE BACK UP LOAD PANELLabel Location:Main Panel Per Code: NEC 705.12.D.2.3.b WARNINGINVERTER OUTPUT CONNECTIONDO NOT RELOCATE THIS OVERCURRENT DEVICELabel Location:Main Panel Per Code: NEC 705.12.D.3 CAUTIONDUAL POWER SOURCESECOND SOURCE IS ENERGY STORAGE SYSTEMLabel Location:Main PanelPer Code: NEC 705.12.D.2.3.c WARNINGTHIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR.Label Location:Service DisconnectENERGY STORAGE SYSTEM ON SITELOCATED ON ADJACENT WALLENERGY STORAGE SYSTEM ON SITELOCATED WITHIN LINE OF SIGHTENERGY STORAGE SYSTEM ON SITELOCATED ON OPPOSITE WALLENERGY STORAGE SYSTEM ON SITELOCATED INSIDELabel Location:Service DisconnectLabel Location:Service DisconnectLabel Location:Service DisconnectLabel Location:Main Panel Per Code: NEC 705.12.D.3 CAUTIONTRI POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMTHIRD SOURCE IS ENERGY STORAGE SYSTEM TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Load Start Capability 106 A LRA for each Powerwall Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,2 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions3 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight3 114 kg (251.3 lbs) Mounting options Floor or wall mount 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 753 mm (29.6 in) 147 mm (5.75 in) 1150 mm (45.3 in) 3Dimensions and weight differ slightly if manufactured before March 2019. Contact Tesla for additional information. TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2021-06-01 Utility meter Grid Backup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional TESLA.COM/ENERGY Backup Gateway 2 POWERWALL 660 411 149 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240V Feed-In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA1 Overcurrent Protection Device 100-200A; Service Entrance Rated1 Overvoltage Category Category IV AC Meter Revenue accurate (+/– 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control, backup, and off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 NA 2020-05-23 1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-flush mount DC- DC+ 1 GD · · · · · DC1 · · · · · DC1 DC- DC+ 1 GD TESLA.COM/ENERGY POWERWALL+ Powerwall+ is an integrated solar battery system that stores energy from solar production. Its integrated design and streamlined installation allow for simple connection to any home, and improved surge power capability brings whole home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their renewable energy needs. KEY FEATURES • Integrated battery, inverter, and system controller for a more compact install • A suite of application modes, including self-powered, time-based control, and backup modes • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates NA 2021-06-23 TESLA.COM/ENERGY POWERWALL+ COMPLIANCE INFORMATION PV Certifications UL 1699B, UL 1741, UL 1741 SA, UL 1998 (US), IEEE 1547, IEEE 1547.1 Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1973, UL 9540, IEEE 1547, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F)5 Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type Type 3R Noise Level @ 1 m < 40 db(A) optimal, < 50 db(A) maximum MECHANICAL SPECIFICATIONS Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in) Total Weight 140 kg (310 lb)4 Battery Assembly 118 kg (261 lb) Solar Assembly 22 kg (49 lb) Mounting options Floor or wall mount 5Performance may be de-rated at operating temperatures below 10°C (50°F) or greater than 43°C (109°F). 1Values provided for 25°C (77°F). 2AC to battery to AC, at beginning of life. 3Cellular connectivity subject to network service coverage and signal strength. NA 2021-06-23 PHOTOVOLTAIC (PV) AND BATTERY ENERGY STORAGE SYSTEM (BESS) SPECIFICATIONS Nominal Battery Energy 13.5 kWh Nominal Grid Voltage (Input / Output)120/240 VAC Grid Voltage Range 211.2 - 264 VAC Frequency 60 Hz Phase 240 VAC: 2W+N+GND Maximum Continuous Power On-Grid 7.6 kW full sun / 5.8 kW no sun1 Maximum Continuous Power Off-Grid 9.6 kW full sun / 7 kW no sun1 Peak Off-Grid Power (10 s)22 kW full sun / 10 kW no sun1 Maximum Continuous Current On-Grid 32 A output Maximum Continuous Current Off-Grid 40 A output Load Start Capability 118 A LRA PV Maximum Input Voltage 600 VDC PV DC Input Voltage Range 60 - 550 VDC PV DC MPPT Voltage Range 60 - 480 VDC MPPTs 4 Input Connectors per MPPT 1-2-1-2 Maximum Current per MPPT (Imp)13 A Maximum Short Circuit Current per MPPT (Isc) 15 A Allowable DC/AC Ratio 1.7 Overcurrent Protection Device 50 A breaker Maximum Supply Fault Current 10 kA Output Power Factor Rating +/– 0.9 to 1 Round Trip Efficiency 90%2 Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi, Ethernet, Cellular LTE/4G)3 PV AC Metering Revenue grade (+/-0.5%) Protections Integrated arc fault circuit interrupter (AFCI), Rapid Shutdown (RSD) Warranty 10 years 160 mm 1596 mm 755 mm 4The total weight does not include the Powerwall+ bracket, which weighs an additional 9 kg (20 lb). TESLA.COM/ENERGY SOLAR SHUTDOWN DEVICE The Tesla Solar Shutdown Device is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall+, solar array shutdown is initiated by turning the Powerwall+ Enable switch off, or by pushing the System Shutdown Switch if one is present. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm NA 2021-06-23 ENVIRONMENTAL SPECIFICATIONS Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4 / IP65 ELECTRICAL SPECIFICATIONS Nominal Input DC Current Rating (IMP)12 A Maximum Input Short Circuit Current (ISC)15 A Maximum System Voltage 600 V DC COMPLIANCE INFORMATION Certifications UL 1741 PVRSS PVRSA (Photovoltaic Rapid Shutdown Array) MECHANICAL SPECIFICATIONS Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD MODULE PERFORMANCE Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally open Maximum Power Consumption 7 W Warranty 25 years PVRSA RSD Initiation Method Opening System Shutdown Switch or turning Powerwall+ Enable switch OFF Compatible Equipment Powerwall+ SOLAR SHUTDOWN DEVICE REQUIREMENTS PER MODULE The following modules have been certified as part of a PV Rapid Shutdown Array (PVRSA) when installed together with Powerwall+ and Tesla Solar Shutdown Devices. See the Powerwall+ Installation Manual for guidance on installing Powerwall+ and Solar Shutdown Devices with other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules TESLA.COM/ENERGY SYSTEM LAYOUTS Powerwall+ with Backup Switch for Whole Home Backup Powerwall+ with Backup Gateway 2 for Whole Home Backup Powerwall+ with Backup Gateway 2 for Partial Home Backup NA 2021-06-23 SOLAR ROOF FLUSH MOUNT DATASHEET 1TESR-DS-0261-21 SOLAR ROOF DATASHEET FOR FULL TEAR-OFF AND OVERLAY INSTALLATIONS SOLAR ROOF FLUSH MOUNT DATASHEET 2TESR-DS-0261-21 These electrical characteristics are within ± 5% of the indicated values of Isc, Voc, and Pmax under standard test conditions (irradiance of 1000 W/m2, AM 1.5 spectrum, and a cell temperature of 25 °C or 77 °F). Irradiance (W/m2) Temp. (Celsius) Voc (V) Vmp (V) Isc (A) Imp (A) Pmax (W) 1000 25 13.34 10.99 5.65 5.32 58.47 MECHANICAL SPECIFICATIONS Dimensions: 430 mm x 1140 mm Thickness: Appx. 5 mm module thickness with 35.3 mm maximum height from deck Principal Materials: Glass, Polymers, Fiberglass and Silicon Installed System Weight: Textured Glass: 15 kg/m² or 3.1 psf ELECTRICAL SPECIFICATIONS Maximum open circuit voltage rating of connected branch circuits per diode (at STC): 13.34 V Maximum series fuse rating: 10 A Maximum system voltage: 600 V CERTIFICATIONS UL 61730 (UL Listed); UL 9703 (UL Listed); UL 1741 (UL Listed) UL 790 Class A (ETL Listed); ASTM D3161 Class F (ETL Listed); TAS100 (ETL Listed) ROOF PITCH RANGE 2:12 - 24:12 Certain features can be installed up to 62:12 14-CELL PV MODULE MODEL #: SR60T1 (Installed weight includes all components of system above roof sheathing or existing roof covering) SOLAR ROOF FLUSH MOUNT DATASHEET 3TESR-DS-0261-21 PV MODULE Model #SR60T1 Listed to UL 61730 UL 790 Class A ASTM D3161 Class F TAS100 DIODE HARNESS Model #SRDTH UL 9703 Listed (ZKLA) ”PV Wire” Short and long lead variants interchangeable PASS THROUGH BOX Model #SRPTB-4 UL 1741, File #E318357 6RODU5RRIZLOOEHLQVWDOOHGRYHUEDUHVROLGRUFORVHO\¿WWHGVKHDWKLQJDVIROORZV • DOC PS-1 compliant / exterior grade plywood: minimum 15/32” (11.9 mm) thick or • DOC POS-2 OSB sheathing: minimum 7/16” thick (11.1 mm) or ‡ &ORVHO\¿WWHGVKHDWKLQJERDUGVPLQLPXPRI´ PP WKLFN Solar Roof can also be installed over compatible existing roofs, as follows: • Three-tab composition shingle, single layer • Architectural composition shingle, single layer Solar Roof will not be installed over raised presidential-style composition shingle, roofs with more than one layer of composition shingle, or existing non-composition shingle roof types like tiled roofs. ROOFING MODULES, FULL AND PARTIAL Model #SRNFT1/6, #SRNFT1/3, #SRNFT1/2, #SRNFT2/3, #SRNFT5/6 and #SRNFT1 Listed to UL 61730 Listed to UL 790 Class A ASTM D3161 Class F TAS100 UNDERLAYMENT Model #SR-SAUL-1 or FT Cobalt FR ASTM D1970/ICC AC48 ICC AC188 ASTM E108 Class -A METAL TILES, FULL AND PARTIAL Model #SRMTT1/6, #SRMTT1/3, #SRMTT1/2, #SRMTT2/3, #SRMTT5/6, #SRMTT1 Listed to UL 1897 Listed to UL 790 Class A ASTM D3161 Class F TAS100 SHEATHING SPECIFICATIONS