HomeMy WebLinkAboutEnergy CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business'and Professional Regulation - Residential Performance Method
Project Name: ALMORE RESIDENCE
Builder Name: TC CUSTOM HOMES
Street: 20025 SOUTHERN STAR DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (5150.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 4920.00 ft2
b. Frame - Wood, Adjacent
R=11.0 230.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
10
d. N/A
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (5810.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 5810.00 ft2
6. Conditioned floor area above grade (ft2)
5810
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (576.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 200
a. U-Factor: Dbl, U=0.32
348.00 ft2
b. Sup: Attic, Ret: Attic, AH: UNIT 2
6 140
SHGC: SHGC=0.19
c. Sup: Attic, Ret: Attic, AH: UNIT 3
6 140
b. U-Factor: Dbl, U=0.32
210.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
46.5 SEER:16.00
b. Central Unit
29.0 SEER:16.00
c. U-Factor: Dbl, U=0.28
18.00 ft2
c. Central Unit
29.0 SEER:16.00
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth:
1.500 ft.
c. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average SHGC:
0.202
14. Hot water systems
a. Electric
Cap: 150 gallons
8. Floor Types (5810.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 5810.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.099
Total Proposed Modified Loads: 168.09
PASS
Total Baseline Loads: 176.90
I hereby certify that the plans and specifications covered by
Review of the plans and
4"t1KE ST•q?,
this calculation are in compliancg with
a Florida Ene
specifications covered by this
y� _ ,�0
Code
&y
calculation indicates compliance
ith the Florida Energy Code.
ti nnr,;;l�..y°•!�„ O
PREPAR Rylc�)Before
construction is completed
DATE: )
this building will be inspected for
compliance with Section 553.908
* _
I hereby certify that thi buildi, as d
igned, is in compliance
Florida Statutes.`,`
with the Florida Energ od
WEB.
OWNER/AG NT•f
BUILDING OFFICIAL:
DATE:
DATE.
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires•an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
File Copy
12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title:
ALMORE RESIDENCE
Bedrooms: 10
Address Type:
Street Address
Building Type:
User
Conditioned Area: 5810
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
TC CUSTOM HOMES
Rotate Angle: 0
Street:
20025 SOUTHERN STA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
W hole House Fan:
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
v
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90
70
75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Block1
2750 27500
2
Block2
1473 14730
3
Block3
1587 15870
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
UNIT 1
2750 27500 Yes 0
4
1 Yes
Yes
Yes
2
UNIT 2
1473 14730 Yes 0
3
1 Yes
Yes
Yes
3
UNIT 3
1587 15870 Yes 0
3
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
UNIT 1 147 ft 0
2750 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulation
UNIT 2 113 ft 0
1473 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulation
UNIT 3 123 ft 0
1587 ft2
----
1 0
0
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 6293 ft2 0 ft2 Medium
0.2
No 0.9
No 0
22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 5810 ft2
N N
12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
UNIT 1
30
Blown
2750 ft2
0.11
Wood
2
Under Attic (Vented)
UNIT 2
30
Blown
1473 ft2
0.11
Wood
3
Under Attic (Vented)
UNIT 3
30
Blown
1587 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing Solar
Below
Space
1
NW
Exterior
Concrete Block - Ext Insul
UNIT 1
4.09999
31
10
310.0 ft2
0
0 0.2
0
2
NE
Exterior
Concrete Block - Ext Insul
UNIT 1
4.09999
46
10
460.0 ft2
0
0 0.2
0
3
SE
Exterior
Concrete Block - Ext Insul
UNIT 1
4.09999
39
10
390.0 ft2
0
0 0.2
0
4
SW
Exterior
Concrete Block - Ext Insul
UNIT 1
4.09999
51
10
510.0 ft2
0
0 0.2
0
5
NW
Exterior
Concrete Block - Ext Insul
UNIT 2
4.09999
54
10
540.0 ft2
0
0 0.2
0
6
NE
Exterior
Concrete Block - Ext Insul
UNIT 2
4.09999
26
10
260.0 ft2
0
0 0.2
0
7
SE
Exterior
Concrete Block - Ext Insul
UNIT 2
4.09999
45
10
450.0 ft2
0
0 0.2
0
8
SW
Exterior
Concrete Block - Ext Insul
UNIT 2
4.09999
26
10
260.0 ft2
0
0 0.2
0
9
NW
Exterior
Concrete Block - Ext Insul
UNIT 3
4.09999
65
10
650.0 ft2
0
0 0.2
0
10
NE
Exterior
Concrete Block - Ext Insul
UNIT 3
4.09999
33
10
330.0 ft2
0
0 0.2
0
11
SE
Exterior
Concrete Block - Ext Insul
UNIT 3
4.09999
43
10
430.0 ft2
0
0 0.2
0
12
SW
Exterior
Concrete Block - Ext Insul
UNIT 3
4.09999
33
10
330.0 ft2
0
0 0.2
0
13
NE
Garage
Frame - Wood
UNIT 1
11
1
10
10.0 ft2
0
0 0.2
0
14
SE
Garage
Frame - Wood
UNIT 1
11
22
10
220.0 ft2
0
0 0.2
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated UNIT 1
None
.27
6
8
48 ft2
2
NW
Insulated UNIT 1
None
.27
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
NE 2
Vinyl Low-E Double
Yes
0.32
0.22
45.0 ft2
1 ft 6 in,
1 ft 4 in
Drapes/blinds
Exterior 5
2
SE 3
Vinyl Low-E Double
Yes
0.32
0.22
30.0 ft2
1 ft 6 in
1 ft4 in
Drapes/blinds
Exterior 5
3
SE 3
Vinyl Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
4
SE 3
Vinyl Low-E Double
Yes
0.32
0.19
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
5
SW 4
Vinyl Low-E Double
Yes
0.32
0.22
30.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
SW 4
Vinyl Low-E Double
Yes
0.28
0.21
6.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
7
NW 5
Vinyl Low-E Double
Yes
0.32
0.19
36.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
8
NW 5
Vinyl Low-E Double
Yes
0.32
0.19
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
9
NE 6
Vinyl Low-E Double
Yes
0.32
0.22
15.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
10
NE 6
Vinyl Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft6 in
1 ft 4 in
Drapes/blinds
Exterior 5
11
SE 7
Vinyl Low-E Double
Yes
0.32
0.22
45.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
12
SE 7
Vinyl Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
13
SW 8
Vinyl Low-E Double
Yes
0.28
0.21
6.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
14
NW
9
Vinyl
Low-E Double
Yes
0.32
0.19
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
15
NW
9
Vinyl
Low-E Double
Yes
0.32
0.19
48.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
16
NE
10
Vinyl
Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
17
NE
10
Vinyl
Low-E Double
Yes
0.28
0.21
6.0 ft2
1 It 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
18
SE
11
Vinyl
Low-E Double
Yes
0.32
0.22
45.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
19
SE
11
Vinyl
Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
20
SW
12
Vinyl
Low-E Double
Yes
0.32
0.19
20.0 ft2
1 ft 6 in
1 ft 4 in
Drapes/blinds
Exterior 5
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
462 ft2
462 ft2
23 ft loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA Egl-A ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.000445
6778.3 372.12 699.83 .3247
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
2
3
Electric Strip Heat
Electric Strip Heat
Electric Strip Heat
None
None
None
COP:1 34 kBtu/hr
COP:1 27 kBtu/hr
COP:1 27 kBtu/hr
1
2
3
sys#1
sys#2
sys#3
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
2
3
Central Unit
Central Unit
Central Unit
None
None
None
SEER: 16 46.5 kBtu/hr 1395 cfm
SEER: 16 29 kBtu/hr 870 cfm
SEER: 16 29 kBtu/hr 870 cfm
0.8 1
0.8 2
0.8 3
sys#1
sys#2
sys#3
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.98 150 gal 130 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
DUCTS
-- Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6
200 ft2
Attic
20 ft2
Default Leakage
Garage
(Default) c(Default) c
1 1
2
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
UNIT 2
(Default) c(Default)
c
2 2
3
Attic
6
140 ft2
Attic
14 ft2
Default Leakage
UNIT 3
(Default) c(Default) c
3 3
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan
HeatinJan
Feb
HFeb
Mar
Mar
f
Apr
Apr f
May
May
[X] Jun Jul
] Jun 4 Jul
Auge
f AuSep
[ ] Oct
[ ] Oct
[ ] Nov
(X] Nov
Dec
Dec
Vent in Jan
Feb
Mar
[X]
Apr [
May
E ] Jun [ Jul
[ Aug
Se
[X] Oct
[X] Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (W D)
AM
68
68
68
68
68 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
68
68
Heating (WEH)
AM
68
68
68
68
68 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
68
68
12/14/2017 8:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ALMORE RESIDENCE Builder Name: TC CUSTOM HOMES
Street: 20025 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/14/2017 9:00 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior
R=4.1
4920.00 ft2
b. Frame - Wood, Adjacent
R=11.0
230.00 ft
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
10 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
5810.00 ft2
6. Conditioned floor area (ft2)
5810 b. N/A
R=
ft2
7. Windows- Description
Area c. N/A
R=
ft2
11. Ducts
R ft2
a. U-Factor: Dbl, U=0.32
348.00 ft2 a. Sup: Attic, Ret: Attic, AH: Garage
6 200
SHGC: SHGC=0.19
b. Sup: Attic, Ret: Attic, AH: UNIT 2
6 140
b. U-Factor: Dbl, U=0.32
210.00 ft2 c. Sup: Attic, Ret: Attic, AH: UNIT 3
6 140
SHGC: SHGC=0.22
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.28
18.00 ft2 a. Central Unit
46.5 SEER:16.00
SHGC: SHGC=0.21
b. Central Unit
29.0 SEER:16.00
c. Central Unit
29.0 SEER:16.00
d. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
1.500 ft. b. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average SHGC:
0.202 c. Electric Strip Heat
27.0
COP:1.00
8. Floor Types Insulation Area 14. Hot water systems
Cap:
150 gallons
a. Slab -On -Grade Edge Insulation R=0.0 5810.00 ft 2 a. Electric
EF: 0.98
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed k
based on installed Cdde co g iant eatures.�
Builder Signature: Date:
Address of New Home: 50 0 h-e. ft, S he r I�rCity/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/14/2017 9:00 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
Prot SJob:
-�- wrightsoft� Project Summary Date: OCT. 25, 2017
UNIT 1 By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS a,10L.COM
For: ALMORE RESIDENCE, TC CUSTOM HOMES
20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
°F
Outside db
90
°F
Inside db
70
°F
Inside db
75
°F
Design TD
28
°F
Design TD
15
*F
Daily range
M
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating
Summary
Sensible Cooling Equipment Load Sizing
Structure
23432
Btuh
Structure
23337
Btuh
Ducts
8761
Btuh
Ducts
124449
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
32194
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
33997
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3484
Btuh
Ducts
3556
Btuh
Area
Heating
Cooling
Central vent 0 cfm)
0
Btuh
2750
2750
Equipment latent load
7040
Btuh
Volumee (ft3)
25072
25072
Air changes/hour
0.20
0.11
Equipment total load
41037
Btuh
Equiv. AVF (cfm)
84
45
Req. total capacity at 0.70 SHR
4.0
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Rheem
Trade
Trade RHEEM
Model
Cond RA1648AJ 1 N B
AHRI ref
Coil RH1T4821MTANJA
AHRI ref 8080956
Efficiency
100 EFF
Efficiency 13.0 EER,
16 SEER
Heating input
7.8
kW
Sensible cooling
32550
Btuh
Heating output
26600
Btuh
Latent cooling
13950
Btuh
Temperature rise
16
°F
Total cooling
46500
Btuh
Actual air flow
1550
cfm
Actual air flow
1550
cfm
Air flow factor
0.048
cfm/Btuh
Air flow factor
0.043
cfm/Btuh
Static pressure
1.00
in H2O
Static pressure
1.00
in H2O
Space thermostat
Load sensible heat ratio
0.84
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Jx.Ie Copy
wrilghtsoft• 2017-Oct-25 09:28:24
_- Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1
'4'A E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE