Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business'and Professional Regulation - Residential Performance Method Project Name: ALMORE RESIDENCE Builder Name: TC CUSTOM HOMES Street: 20025 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (5150.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 4920.00 ft2 b. Frame - Wood, Adjacent R=11.0 230.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 10 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (5810.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 5810.00 ft2 6. Conditioned floor area above grade (ft2) 5810 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (576.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 200 a. U-Factor: Dbl, U=0.32 348.00 ft2 b. Sup: Attic, Ret: Attic, AH: UNIT 2 6 140 SHGC: SHGC=0.19 c. Sup: Attic, Ret: Attic, AH: UNIT 3 6 140 b. U-Factor: Dbl, U=0.32 210.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 46.5 SEER:16.00 b. Central Unit 29.0 SEER:16.00 c. U-Factor: Dbl, U=0.28 18.00 ft2 c. Central Unit 29.0 SEER:16.00 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. c. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average SHGC: 0.202 14. Hot water systems a. Electric Cap: 150 gallons 8. Floor Types (5810.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 5810.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 168.09 PASS Total Baseline Loads: 176.90 I hereby certify that the plans and specifications covered by Review of the plans and 4"t1KE ST•q?, this calculation are in compliancg with a Florida Ene specifications covered by this y� _ ,�0 Code &y calculation indicates compliance ith the Florida Energy Code. ti nnr,;;l�..y°•!�„ O PREPAR Rylc�)Before construction is completed DATE: ) this building will be inspected for compliance with Section 553.908 * _ I hereby certify that thi buildi, as d igned, is in compliance Florida Statutes.`,` with the Florida Energ od WEB. OWNER/AG NT•f BUILDING OFFICIAL: DATE: DATE. - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires•an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). File Copy 12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: ALMORE RESIDENCE Bedrooms: 10 Address Type: Street Address Building Type: User Conditioned Area: 5810 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: TC CUSTOM HOMES Rotate Angle: 0 Street: 20025 SOUTHERN STA Permit Office: ST LUCIE COUNTY Cross Ventilation: County: St. Lucie Jurisdiction: W hole House Fan: City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE v IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 2750 27500 2 Block2 1473 14730 3 Block3 1587 15870 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 UNIT 1 2750 27500 Yes 0 4 1 Yes Yes Yes 2 UNIT 2 1473 14730 Yes 0 3 1 Yes Yes Yes 3 UNIT 3 1587 15870 Yes 0 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation UNIT 1 147 ft 0 2750 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation UNIT 2 113 ft 0 1473 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation UNIT 3 123 ft 0 1587 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 6293 ft2 0 ft2 Medium 0.2 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 5810 ft2 N N 12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) UNIT 1 30 Blown 2750 ft2 0.11 Wood 2 Under Attic (Vented) UNIT 2 30 Blown 1473 ft2 0.11 Wood 3 Under Attic (Vented) UNIT 3 30 Blown 1587 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NW Exterior Concrete Block - Ext Insul UNIT 1 4.09999 31 10 310.0 ft2 0 0 0.2 0 2 NE Exterior Concrete Block - Ext Insul UNIT 1 4.09999 46 10 460.0 ft2 0 0 0.2 0 3 SE Exterior Concrete Block - Ext Insul UNIT 1 4.09999 39 10 390.0 ft2 0 0 0.2 0 4 SW Exterior Concrete Block - Ext Insul UNIT 1 4.09999 51 10 510.0 ft2 0 0 0.2 0 5 NW Exterior Concrete Block - Ext Insul UNIT 2 4.09999 54 10 540.0 ft2 0 0 0.2 0 6 NE Exterior Concrete Block - Ext Insul UNIT 2 4.09999 26 10 260.0 ft2 0 0 0.2 0 7 SE Exterior Concrete Block - Ext Insul UNIT 2 4.09999 45 10 450.0 ft2 0 0 0.2 0 8 SW Exterior Concrete Block - Ext Insul UNIT 2 4.09999 26 10 260.0 ft2 0 0 0.2 0 9 NW Exterior Concrete Block - Ext Insul UNIT 3 4.09999 65 10 650.0 ft2 0 0 0.2 0 10 NE Exterior Concrete Block - Ext Insul UNIT 3 4.09999 33 10 330.0 ft2 0 0 0.2 0 11 SE Exterior Concrete Block - Ext Insul UNIT 3 4.09999 43 10 430.0 ft2 0 0 0.2 0 12 SW Exterior Concrete Block - Ext Insul UNIT 3 4.09999 33 10 330.0 ft2 0 0 0.2 0 13 NE Garage Frame - Wood UNIT 1 11 1 10 10.0 ft2 0 0 0.2 0 14 SE Garage Frame - Wood UNIT 1 11 22 10 220.0 ft2 0 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated UNIT 1 None .27 6 8 48 ft2 2 NW Insulated UNIT 1 None .27 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 2 Vinyl Low-E Double Yes 0.32 0.22 45.0 ft2 1 ft 6 in, 1 ft 4 in Drapes/blinds Exterior 5 2 SE 3 Vinyl Low-E Double Yes 0.32 0.22 30.0 ft2 1 ft 6 in 1 ft4 in Drapes/blinds Exterior 5 3 SE 3 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 4 SE 3 Vinyl Low-E Double Yes 0.32 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 5 SW 4 Vinyl Low-E Double Yes 0.32 0.22 30.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 6 SW 4 Vinyl Low-E Double Yes 0.28 0.21 6.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 7 NW 5 Vinyl Low-E Double Yes 0.32 0.19 36.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 8 NW 5 Vinyl Low-E Double Yes 0.32 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 9 NE 6 Vinyl Low-E Double Yes 0.32 0.22 15.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 10 NE 6 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft6 in 1 ft 4 in Drapes/blinds Exterior 5 11 SE 7 Vinyl Low-E Double Yes 0.32 0.22 45.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 SE 7 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 13 SW 8 Vinyl Low-E Double Yes 0.28 0.21 6.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 NW 9 Vinyl Low-E Double Yes 0.32 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 15 NW 9 Vinyl Low-E Double Yes 0.32 0.19 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 16 NE 10 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 17 NE 10 Vinyl Low-E Double Yes 0.28 0.21 6.0 ft2 1 It 6 in 1 ft 4 in Drapes/blinds Exterior 5 18 SE 11 Vinyl Low-E Double Yes 0.32 0.22 45.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 19 SE 11 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 20 SW 12 Vinyl Low-E Double Yes 0.32 0.19 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 23 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA Egl-A ACH ACH 50 1 Wholehouse ProposedACH(50) .000445 6778.3 372.12 699.83 .3247 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 3 Electric Strip Heat Electric Strip Heat Electric Strip Heat None None None COP:1 34 kBtu/hr COP:1 27 kBtu/hr COP:1 27 kBtu/hr 1 2 3 sys#1 sys#2 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit Central Unit Central Unit None None None SEER: 16 46.5 kBtu/hr 1395 cfm SEER: 16 29 kBtu/hr 870 cfm SEER: 16 29 kBtu/hr 870 cfm 0.8 1 0.8 2 0.8 3 sys#1 sys#2 sys#3 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 150 gal 130 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 12/14/2017 8:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 DUCTS -- Supply -- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 20 ft2 Default Leakage Garage (Default) c(Default) c 1 1 2 Attic 6 140 ft2 Attic 14 ft2 Default Leakage UNIT 2 (Default) c(Default) c 2 2 3 Attic 6 140 ft2 Attic 14 ft2 Default Leakage UNIT 3 (Default) c(Default) c 3 3 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Feb HFeb Mar Mar f Apr Apr f May May [X] Jun Jul ] Jun 4 Jul Auge f AuSep [ ] Oct [ ] Oct [ ] Nov (X] Nov Dec Dec Vent in Jan Feb Mar [X] Apr [ May E ] Jun [ Jul [ Aug Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (W D) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 12/14/2017 8:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ALMORE RESIDENCE Builder Name: TC CUSTOM HOMES Street: 20025 SOUTHERN STAR DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/14/2017 9:00 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 4920.00 ft2 b. Frame - Wood, Adjacent R=11.0 230.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 10 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 5810.00 ft2 6. Conditioned floor area (ft2) 5810 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 11. Ducts R ft2 a. U-Factor: Dbl, U=0.32 348.00 ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 200 SHGC: SHGC=0.19 b. Sup: Attic, Ret: Attic, AH: UNIT 2 6 140 b. U-Factor: Dbl, U=0.32 210.00 ft2 c. Sup: Attic, Ret: Attic, AH: UNIT 3 6 140 SHGC: SHGC=0.22 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.28 18.00 ft2 a. Central Unit 46.5 SEER:16.00 SHGC: SHGC=0.21 b. Central Unit 29.0 SEER:16.00 c. Central Unit 29.0 SEER:16.00 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average SHGC: 0.202 c. Electric Strip Heat 27.0 COP:1.00 8. Floor Types Insulation Area 14. Hot water systems Cap: 150 gallons a. Slab -On -Grade Edge Insulation R=0.0 5810.00 ft 2 a. Electric EF: 0.98 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed k based on installed Cdde co g iant eatures.� Builder Signature: Date: Address of New Home: 50 0 h-e. ft, S he r I�rCity/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/14/2017 9:00 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 Prot SJob: -�- wrightsoft� Project Summary Date: OCT. 25, 2017 UNIT 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS a,10L.COM For: ALMORE RESIDENCE, TC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 *F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23432 Btuh Structure 23337 Btuh Ducts 8761 Btuh Ducts 124449 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32194 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33997 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3484 Btuh Ducts 3556 Btuh Area Heating Cooling Central vent 0 cfm) 0 Btuh 2750 2750 Equipment latent load 7040 Btuh Volumee (ft3) 25072 25072 Air changes/hour 0.20 0.11 Equipment total load 41037 Btuh Equiv. AVF (cfm) 84 45 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1648AJ 1 N B AHRI ref Coil RH1T4821MTANJA AHRI ref 8080956 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.8 kW Sensible cooling 32550 Btuh Heating output 26600 Btuh Latent cooling 13950 Btuh Temperature rise 16 °F Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Jx.Ie Copy wrilghtsoft• 2017-Oct-25 09:28:24 _- Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 '4'A E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE