Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
Job: Project Summary Date: OCT. 25, 2017 UNIT 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For: ALMORE RESIDENCE, TC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Heating Summary Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Structure 23462 Btuh Ducts 4303 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 27765 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Coolin Area (ft2) 1473 14A Volume (ft3) 15140 15140 Air changes/hour 0.36 0.19 Equiv. AVF (cfm) 90 48 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 25022 Btuh 967 cfm 0.035 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 M OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 15964 Btuh Ducts 6067 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 20929 Btuh Latent Cooling Equipment Load Sizing Structure 3221 Btuh Ducts 1624 Btuh Central vent 0 cfm) 0 Btuh Equipment latent load 4846 Btuh Equipment total load 25774 Btuh Req. total capacity at 0.70 SHR 2.5 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1630AJ 1 NA Coil RH1T3617STANJA AH R I ref 7941343 Efficiency 13.0 EER, 16 SEER Sensible cooling 20300 Btuh Latent cooling 8700 Btuh Total cooling 29000 Btuh Actual air flow 967 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c - wrightsoft® 2017-Oct-25 09:28:24 �• Right -Suite@) Universal 2017 17.0.08 RSU08101 Page 2 '4Cr-*1 E:\Documnets\Wrightsoft WAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE - wrightsoft® Project Summary UNIT 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS a(�AOL.COM For: ALMORE RESIDENCE, TC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL Notes: Job: Date: OCT. 25, 2017 By: Design In• • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20129 Btuh Structure 16776 Btuh Ducts 4052 Btuh Ducts 5733 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24180 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 21383 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2827 Btuh Ducts 1538 Btuh Heating Coolingg Central vent 0 cfm) 0 Btuh Area (ft2) 1587 1587 Equipment latent load 4365 Btuh Volume (ft3) 13720 13720 Air changesthour 0.34 0.18 Equipment total load 25749 Btuh Equiv. AVF (cfm) 77 41 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1630AJlNA AHRI ref Coil RH1T3617STANJA AH R I ref 7941343 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.5 kW Sensible cooling 20300 Btuh Heating output 25693 Btuh Latent cooling 8700 Btuh Temperature rise 24 OF Total cooling 29000 Btuh Actual air flow 967 cfm Actual air flow 967 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C - wrightsoft® 2017-Oct-25 09:28:24 .+- Right -Suite® Universal 2017 17.0.08 RSU08101 14CC'lk` E:\Documnets\wrightsoft WAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 3 wrightsoftRight-M Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name UNIT 1 MASTER BATH 2 F)posed wall 192.0 ft 37.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 2507.2 ft' 1.0 x 196.0 ft 196.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuh/ft? °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 --- - 13A-456s -- - - - --, 2 glazing, clr low-e - - -0.143 0.650' _-ne . ne _. _ 4A0 0.00 .._ 2.19 0.00 650 0 505 0 -2022 0 .. _ .. 1105 0 ._ _ 80 0 .� - ' 80 0 k_0 0 0 2 glazing, clr low-e 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 -- _ 2 glazing, clr low-e 2.glazing,dr low=e__ -- 0.650 __0.650 ne - ne- 18.20 ---- 0.0.0 26.88 _.__ 0.00 45 ._ _ . -- - 0 0 ---- ---. - 3 819 ---- --0 1209 ---- -- ----0 0 --- -3 0 - --- - - _0 0 0 - ---- �. -__----0- _ 200 - 200 0 W 13A-4ocs 13A-0ocs -_- 2 glazing, cir low-e 0.143 0.143 0.650 a _-se se 4.00 4.00 0.00 2.19 _ �2.19 0.00 __ _ 50 300 0 _ _ _ _ 50 _ 202 0 200 -- -�809 0 _ _ 109 442 0 _ __ _ _ 50 ' 70 0 _ __ 50 - - 50 0 109 - _109 0 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 se se 18.20 18.20 ,' 23.35 23.35 .30 20 9 6 546 364 700 467 0 20 0 6 0 364 0 467 --__ - W 2 glazing, clr low- 2.gIazing, clr Iow_e_ _- 13A4ocs 0.650 ----- _ 0.650 0.143 se _se_ s 0.00 _-_18.20 4.00 0.00 - -- 24.74 2.19 0 _ 50 50 0 __ _-- _ 9 50 50 0 _--- ___874 200 0 --_- - _1187 109 0 -__-_0 50 0 _ _ TO 50 0 .- _ - - 0 200 0 _--_._0- 109 _ _ - - 13A-flocs - - - - 2 glazing, clr low-e - -0.143 0.650 sw sw 4.00 18.20 - _- 2.19 17.79 -- 566 6 - 514 5 - 2058 109 1126 107 - - 120 6 -114 5 - - 466 109 249 107 2 glazing, clr low-e 2 glazing, clr low-e -2glazing,clrlowe---------0;650--sw----_0.00.----0.00------._03_._--._-0- 0.650 0.650 sw sw 0.00 18.20 0:00 23.35 0 30 0 9 0 .546 0 700 ----- - 0._____-_0._--------0�---9 0 0 0 0 0 0 0 0 ----__-0. 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 420 0 0 324 0 0 1297 0 0 709 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11G0 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 96 0 96 0 0 1374 0 0 0 0 0 0 0 0 ---- C _._ - - -_ - 168 30ad - - ------ - _ 0.032 -- - _� - - - __0.9Q ---- - __-__1.60 _ _ __2506 Y _ _.._ -2506 _1452 _ ____2245 ___4010 _ y __�196 - - _ _196. - -- --, 176 - - - _-._314. F ---° 22A tDh-_ -- - --- --__. 1 _358 r._ _ .. _ _38.02 0.00 _ - -2506 -192 ... _ 7301 _ . - - -0 - -w -196 - - 37 _ 1407 - __0 6 c)AED excursion 0 -24 Envelope loss/gain 20842 13354 3433 1616 12 a) Infiltration 2591 743 499 143 b) Room ventilation 0 01 01 0 13 Internal gains: Occupants @ 230 8 1840 0 0 Appliances/other 7400 0 Subtotal (lines 6 to 13) 23432 23337 3932 1760 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 23432 0 0 23337 0 0 3932 0 0 1760 Duct loads 1 37% 53% 8761 12449 37% 53% 1470 939 r Total room load Air required (cfm) 32194 1550 35786 1550 5403 260 2698 117 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. �A- wright50ft' 2017-Oct-25 0 Right -Suite@ Universal 2017 17.0.08 RSU08101 Page ae 1 E:\Documnets\Wrightsoft WAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 -'�- wrightsoft° Right-J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BEDROOM LIVING ROOM 2 3 4 5 Exposed wall Room height Room dimensions Room area 43.0 ft 10.0 ft heat/cool 1.0 x 467.0 ft 467.0 ft2 14.0 ft 10.0 ft heat/cool 14.0 x 27.1 ft 379.2 ft2 Ty Construction number U-value (Btuh/f? °F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A flocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr Wt-e 0.143 0.650, 0.650 0.650 _ 7_ ne ne he ne _.._�._..____ 4.00 0.00 0.00 ' 18.20 2.19 0.00 0 00 26.88 ry 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0• 0 0 0 0 0 0 0 0 0 0 0 0 11 w .2.glazing,:clr low-ew___ 13A-4ocs . 13A-4ocs 2 glazing, clr.low-e 2 glazing,,clr low-e 2 glazing, clr low-e 2 glazing, clr low-e .2,glazing, clr low�ea_ 13A-4ocs 13A flocs - .T�___0.650 _ _ 0 143 0.143 0.650 0.650 0.650 0.'650 _.0.650 0.143 U.143 _ne_, ___.e se se se se" se , se_ s sw _ 0.0Q ._._. 4 s00 4.00 0.00 18.20 18.20 0:00 ____j8.20. 4.00 4.00 _, 0..00 __h2 19 2.19 . 0.00 23.35 23.35 0.00 24.7.4 2.19 2.19 0 _ ---0 0 0 0 0 _.._.._0 0 µ 270 _. 0 ._ -._ _____0 0 0 0 0 __0 0 ' " 240 .� _._0 __-- -_-. 0 0 0 0 0 0 .,_,____0 0 961 _--__ _ _0 . �__._. 0 0 0 0 0" 0 ____0 0 "� 525 r _ _0 _,_____.0 0 0 0 0 0 0 A ___T9. __. _ 0 0 0 0 0 0 0 D _ Q ...__0 0 0 0 0' 0 ____0. 0 0 __'0, _ .� 0 0 0 0 0 0 0 " 0 W _ W C 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing,_clrlow-e____ 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 11GO -16B-30ade._. _ ___ __ 0.650 0.650 0.650 _ __ 0.650 0.143 0.650 0.650 0.650 0.540 _ _ __0 032 : sw sw sw __sw nw nw nw nw nw ___ T 18.20 0.00 ,1810 _. 0 00.__..A.00 4.00 0.00 0.00 0.00 15.12 _.� 0.9Q 17.79 ^ 0.00 • 23.35 2.19 0.00 0.00 0.00 14.31 ,__ 1.60 - 0 0 30 -__ 160 0 0 0 0 467 0 0 9 _._._ _ 160 0 0 0 0 __ __ 467 0 0 546 0 641 0 0 0 0 _,418 0 0 700 .__9 350 0 0 0 0 �_ 7,47. 0 0 0 140 0 0 0 48 __._.378 0 0 0 92 0 0 0 _ _ _48 __-,__ 378 0 0 0 368 0 0 0 726 _____ 339- 0 0 0 201 0 0 0 687 -__...__605, 38.02 ,.----0 00 _ _ 467 ._ _. 43 _;,__ 1635 0 __,..,.__._378 14 - 532 _- -- 6 c)AED excursion 148 -114 Envelope loss/gain 4201 2470 1965 1379 12 a) Infiltration 580 167 189 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 900 1500 Subtotal (lines 6 to 13) 4781 3997 2154 2934 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4781 3997 2154 2934 151 Duct loads 137% 53%1 1788 2132 37% 53% 805 1565 Total room load Air required (cfm) 6569 316 6129 265 2959 1421 4499 195 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed. A wright50ft` 2017-Oct-25 0 Right -Suite® Universal 2017 17.0.08 RSU08101 Page ae 2 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 -�- wrightsoft Right-J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name FAMILYROOM BEDROOM 3 2 Exposed wall 12.0 ft 13.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 12.0 x 15.0 ft 180.0 ftz 1.0 x 176.0 ft 176.0 ft' Ty Construction number U-value (Btuh/ft�°F) Or HTM (Btuh/ft2) Area (ft') or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 -- - 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e -0.143 0.650 0.650 ne ne ne 4.00 0.00 0.00 - _ 2.19 0.00 0.00 --- - 0 0 0 - -- 0 0 0 - -- 0 0 0 - - -0 0 0 - - 130 0 0 - - 115 0 0 --- 460 0 0 - -252 0 0 11 2 glazing, clr low-e .2.glazing,-clr low-e-__._ 0.650 ----0.650 ne _ne_ 18.20 _ _-0.00 26.88 ______0.00 0 ------._0 0 _-----0 0 _ -----0 0 ------9 15 - -----0 0 ------- -0 273 -----0 403 ---- ----0 ---_-_ _ W 13A-4ocsY- - -- 13A-flocs 2 glazing, clr low-e -- -0.143 0.143 0.650 e _ _-,_4.00 4.00 0.00 2.19 2.19 0.00 - - - 0 6 0 - - - 0 0 0 - - -0 0 0, - 0 0 0 -- - - 0 0 0 -- --0 0 0 - --0 0 0 - - - 0 0 0 _ se se 2 glazing, clrlow-e 2 glazing, clr low-e 0.650 0.650 se se 18.20 18.20 23.35 23.35 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, clr low-e 2.glazing,_clr louvre__---- 13A-4ocs 2 glazing, clr low-e 0.650 ---_0.650 0.143 0.650 se _ se_ s sw 0:00 __ -18.2Q 4.-2 4.00 18.20 0.00 24J4 2.19 -- -2.19' 17.79 0 _--- 0 0 - - 0 0 0 --_--_0 0 - 0 0 0 -----_-- :0 0 - 0 0 0 -- 0 0 - 0 0 0 ._--_-- _0 0 _._._.._�.- 0 0 0 . - --0 0 0 0 - -- _0 0 0 0 - ---0 0 2 glazing, clrlow-e 2 glazing, clr low-e 2.glazing,_clr low-e _ 0.650 0.650 0.650 sw sw sw- 0.00 18.20 ___0.00 0.00 23.35 __0.00 0 0 0 0 0 _0 0 0 ____0 0 0 _ __0 0 0 0 0 D 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 120 0 0 72 0 0 288 0 0 158 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 nw rnv..__.15,12 0.00 0.00 0 48-___.- 0 48 0 726- 0 0 0 0 0 __.11G0.__ ..- -_0-540 _-___0.032 -_ _ --_0.9Q __...-_Ii -___ -1.60 __ _-.__ ___180 _ __..._180 ____ _ -_ _.-161. ---687___ ___288 - - ._---__.176 _ . -_ 1.7.6 - ----0 - ___ 158 ---0 282. ---- ----- ---- . ------- 1.358 -- - _ - 38.02 - . 0.00 - - -180 _. -12 _ 456 -0 -- 1.76 ___ 13 _ 494- 6 c)AED excursion -48 -73 Envelope loss/gain 1632 1085 1385 864 12 a) Infiltration 162 46 175 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 100 1 500 Subtotal (lines 6 to 13) 1794 1231 1561 1874 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 12 108 52 14 Subtotal 1801 1243 1668 1926 Duct loads 137% 53% 673 663 37% 53% 624 1028 r Total room load 2474 1907 2292 2954 Air required (cfm) 119 83 110 128 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. C*�wrightSOft" Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 0 Page 3 E:\Dccumnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MA Front Door faces: SE 9 - wrightsoftRight-J® Worksheet Job: UNIT % Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS@/\OL.COM. 1 Room name CLST 3 HALL 2 3 Exposed wall Room height 2.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 2.0 ft 20.0 ft2 1.0 x 82.0 ft 82.0 ft2 Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ft�) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 2 glazing, clr low-e 2 glazing, clr low-e 0:143 0:650 0.650 ne ne 'ne ' -' 4.00 - 0.00 0.00 7--fi-9 0 00 0.00 , 20 0 0 20 0 0 80 0 0 44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 _ _ 2 glazing, clr low-e 2 glazing, clr b"__ , 0.650 _.--__._0.650 ne .. ne_ 18.20 __.-__0.0.0- 26.88 0 00 0 __.W__._0 0 _.__e:__:0 0 _-__--_0 0 _-____-_0 0 ___ 0 D _._--0 0 0 w __- . s13A-4ocs � 13A-flocs, 2 glazing, clrlow-e 0.143 0:143 0.650 e_ se se, __4.00 4.00 0:00 . 2e19 2:19 0.00 �. 0 0 0 0 0 0 _- -__0 0 0 _--- 0 0 0 ._ 0 0 0 _ 0 ___6 0 0 0 0 c 0. 0 0 2glazing, clrlow-e 2 glazing, clr low-e 0.650 0.650 se, se 18.20 18.20 . 23.35 23:35 0 0 0 0 D 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2:glazing, clr_low a 0.650 �_-.___0.650 se _se...-_._24.74:._..__.-. 0.00 0:00 0 0 0 0 0 0 0 -.-------- 0 W - 13A-4ocs 2 glazing, c(r low-e' 0.143 ______ 0.143 0.650 s `sw- sw 4.00 �'--4.00 18.20 2.19 -`+ 2 19 17.79 0 __-__: 6 0 0 ._, ___, O 0 0 ---_.�___. 0 0 0 .__ __n _ 0 0 _ __0 0 0 -----.0 0 0 __ -a 0 .0 -__-. 0. 0 _ 2 glazing, clr low-e 2 glazing, clr low-e _2.91azing, clr low ems.'_ 0.650 0.650 _,_-0.650 sw sw _s_w_ 0.00 18.20 0;00 0.00 -23.35 - w0 00 0 0 __._ _ 0 0 0 _ q 0 0 ___.A 0 0 _ _ 0 0 0 _ -- . 0 0` 0 ____q _ 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11G0 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C_._ __ 166 30ad _ _ .- -___. 0 032 _- ._ _. _ _0.90. _ 1.60 __ ._.__._20 ___-_ _20 __ 18 .__ _ 32 _ ..__ _82 -82 ____ _73- _.- _ 13_ _._____1.358 _ 38,02, �__.0.00 .__.__20 2 76..___._ _ _ 0 ___-._.82 _ 0 �- _0 _-0 6 c)AED excursion -3 5 Envelope loss/gain 174 731 73 126 12 a) Infiltration 27 8 0 0 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 201 80 73 126 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -201 -80 -73 -126 14 Subtotal 0 0 0 0 15 Duct loads 37% 53%1 0 0 37% 53%l 0 0 Total room load 0 0 0 0 Air required (cfm) 0 0 0 0. Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WPiightSOft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09P.' A&k age 4 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 - wrightsoft° Right-J® Worksheet Job: UNIT % Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a(AOL.COM 1 Room name KITCHEN FOYER 2 Exposed wall 0 ft 9.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 12.0 x 17.0 ft 204.0 ft2 9.0 x 11.0 ft 99.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, clr low-e 2glazing, clr low-e' 0.143 0.650 0.650 ne ne ne 4.00' 6.00 0.00 2:19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 _ 2 glazing, clrlow-e :2.glazing, clrlow ea _. 0.650 ,_---0.650 ne ne, 18.20 _. __0.00 26.88 _---..0.00 0 -.__.,_ 0 0 , _.._syr 0 0. _ u_--- -0 0 '_._ _ _0 0 _. _ _. 0 0 . _0, 0 _.0 0 ._-__ _ 0. W 13A4acs 13A-flocs 2 glazing, cir low-e 0.143 __.__. 0.143 0:650 a __ se se 4,00 �__ ___ _ 4:00 0.00 2.19 __.._ ,__ . 2.19 0.00 a -_Tr 0___ . 0 0 0 .�_ A 0 0 _ _..�._ 0 0 0 _._ . 0 0 0 -_. 90 0 0 . __. 42 0 0 0 -_ 168 0 92 0 2 glazing, clr low-e . 2 glazing, clr low-e 0.650 0.650 se se 18!20 18.20 23.35 23.35 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, cir low-e .2 glazing, clr-Iow e___'_.___,_,0.650 13A-4ocs 2 glazing, cir low-e 0.650 0.143 0.650 se __se_ s sw 0.00 _v18.2Q 4.00 18.20 , .0,00 ,__24'.7_4 2.19 17.79 0 _0 0 - 0 0 ' .___-:0 0 � 0 0 _0 0 � 0 0 .__-_____0 0 O 0 0 __;___.48 0 -_---.-0 0 0 ,__9 0 0 0 --� 0 0 0 0 0 . 2:glazing, cir low-e 2 glazing, clrlow-e 2 glazing, clr lower - 0.650 0.650 0.650 . sw sw _sw_ 0.00 18.20' r__- 0.'00m 0.00 23.35 _ 000 0 0 0 '. 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4,00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11GO 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 204 ___18.3._-y__-_.__3_2_6-_-_____99 99.__-_-_-- __8R _w__ .358 _ 38,0 _ ____.._d___2_0_4 99 9_3422__ 6 c)AED excursion -87 256 Envelope loss/gain 183 2401 14731 1694 12 a) Infiltration 0 0 121 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 183 2240 1594 1729 Less eAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 24 41 0 0 14 Subtotal 207 2281 1594 1729 151 Duct loads 37% 63%1 77 1217 37% 53% 596 922 Total room load 284 3498 2190 2651 Air required (cfm) 141151 105 115 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrig17t50ft" Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 0 Page I&S" e 5 E:\Documnets\Wrightsoft WAC\ALMORE RESIDENCE.rup Calc = WS Front Door faces: SE 9 - wrightsoft° Right,J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M WIC 1 DINING ROOM 2 Exposed wall 7.0 ft 14.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 7.0 ft 35.0 ft2 1.0 x 182.0 ft 182.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1 13A-4ocs 2 glazing, clr low-e 2 glazing, clriow-e 0.650 0.650 ne ne 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 _ _ 2 glazing, clr low=e 2_glazing, clr low-e__..n 0:650 ____. _0,650 ne -ne- 18:20 --- O'OQ 26.88 -_0.00 0- 0 0 _.._ . _._0 0 0 _____„ 0 0 __._____0 0 s.-_.. _._ 0 0 0 w 13A-4ocs 2 glazing, cIr low-b 0.143 0:143 0.650 a - se se 4.00 ------- 4'd O.OQ _ 2.19 --2.16 '0.00 0 0 0 0 .. __- _. 6 0 0 -_ _._..__0 0 0 6 0 0 . _ �40 0 0 _110 0 0 _ � 0 0 __v_- 241 0 2 glazing;-cir low-e 2glazing, clrlow-e 0.650 0.650 se 'se . 18.20, 18.20 _ 23.35 23.35 0 0 0 0 0 0 0 0 30 0 9 0 546 0 700 0' _U13A13ocsT.________ . W 2glazing, clrlow-e 2glazing,,;clr low-e_._" 13A-4ocs flocs 6.650 _____ _0.650 0.143 se _se_- s 0.06 __ _ 18.20' 4.00 0.00 _._24.74 2.19 IA-9 0 ___0 0 0 0 0 70 0 --_0 0 280 0 0 - 153 0 _M -0 0 0 -.---._--.._0 0 0 _---_--_6 0 -__ 0 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2.glazin9,_clrlowe__ _. 0.650 0.650 0.650 _ s_w0.1i50 sw sw sw sw 18.20 0.00 18.20 _. WGQ 17.79 0.00 - 23.35 _._ 0.00 0 0 0. _dm_m:9 0 0 0 _.__.___0 0 0, 0 0 0 0 0 0 0 _._._.._4 0 1 40 1 0 _.___ 0 0 , 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00, 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11G0 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 032 _ _0.90, 1.60 _ 35 _. 35 - � ____._31, -_ 318.02 __--_0.00, _. . 35 .? 266 - 0 _ 182 _ _-_. k,14 532 _.r r. 0 6 c)AED excursion -9 143 Envelope loss/gain 578 2001 1682 1376 12 a) Infiltration 94 27 189 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13) 672 227 1871 2330 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 10 14 Subtotal 672 227 1877 2340 15 Duct loads 37% 53% 251 121 37% 53% 702 1248 Total room load 924 349 2578 3588 Air required (cfm) 44 EL 11241 155 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. .0 -Fk wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09:28:24 �� E:\Documnets\Wrightsoft WAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 6 - - wrightsoft° Right-J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY CLST 4 2 Exposed wall 9.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 2.0 x 9.0 ft 18.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/W-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs ' 2 glazing, clr low-e 2glazing, clr low-e 0:143 0.650 0.650 he ne ne 4.00' '0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0" 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glaz ng_clr-low_e,-_ 0.650 _ 0;650 ne _.ne-- 18.20 -----0.00, - 26.88 ._ 0:00 0 .__.,.,__ _0 0 . ._0 0 .______0 0 0 0 0 0 W 13A-4ocs 13A-flocs 2 glazing, clr low-e 0.143 0.143, 0.650 a se se 4.00 4.00 0.00 2.19 2.19 0.00 0 _.._ 0 0 0 _ _ ,0 0 0 _ _ _. _-0 0 0 _ -.-._ ..__0 0 0 _ .__ 0 0 0 -. ---_ _ 0 0 0 - - 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650, 0.650 se se, 18.20 18.20 23.35 23.35 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _.2-glazing, W 2 glazing, clr low-e clr.lowre- 13A-4ocs 0.650 .,._ --__0:650 0.143 se ... se_ s 0.00 _._.._18.20-__. 4.00 0.00 24.74 2.19 0 -mm.____ 0 0 0 ___. ___._0 0 0 _-_----Q 0 0 --_.__0 0 0 ______.__ 0 0 0 ___. ___0 0 0 --__ _0 0 0 ..__ _..__Q. 0 4 13A�ocs 2 glazing, cir low-e _ _ _ v 0.143 0.650 sw- sw _ - 4.00 18.20 _ -� 2.19 17.79 -- -- 90 0 _ - -�- 90 0 --_ 9ti0 0 � ' 197 0 0 0 4 -- _ 0 0 _. _ 0 0 _ _ ' 0 0 2 glazing, cir low-e 2 glazing, clr low-e clrlpwa __, 0.650 0.650 _.._065, sw sw _sw_. 0.00 18.20 ____0.00 0.00 23.35 ......040 0 0 0 0 0 __._0 0 0 .0----- 0 0 0 0 0 4 0 0 __.T 0 0 0 0 _ _---2,glaz(ng, 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11GO 0.650 0.540 nw nw_ 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 032 _ - _- ._.___0 90 _ _ . 1.60 _..-_54 _ _ ___ 54 .---_--48 -- _---_86 .__... _0 ._18 --_.._- _. _ --- _ - .18 _-- _ -.16- __- ._-- _.. 29: 1.358 . 38.02 _.._ _0.00 54 .__ _ 9 ._ _. 342 _ 0_ _ � _ _18 ..___ 0. --_--_ ---0 _ _._.0_ 6 c)AED excursion -30 -1 Envelope loss/gain 751 253 16 28 12 a) Infiltration 121 35 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 872 788 16 28 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 12 -16 -28 14 Subtotal 880 800 0 0 Duct loads 37% 53% 329 427 37% 53% 0 0 r Total room load 1209 1227 0 0 Air required (cfm) 1 58 53 10 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. r_ .4C � wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 0 :28:24 7 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 -�- wrightsoft° Right-J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name BEDROOM 4 M WIC 2 2 E)qosed wall 12.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 14.0 x 12.0 ft 168.0 ft' 5.0 x 7.0 ft 35.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -- 13A-4ocs - - - 2 glazing, cir low-e 2 glazing, cir low-e --0.143 0.650 0.650 ne ne ne - 4.00 0.00 0.00 --- 2.19 0.00 0.00 -120 0 0 -..105 0 0 - - - 420 0 0 ' - TM 0 0 - - 0 0 0 - --0 0 0 --- ------0 0 0 ----0 0 0 11 2 glazing, clr low=e .2_glazing; cIr,IQx -____ 0.650 .- ._0.650 ne __.ne_ 18.20 -- "0.00, 26.88 _ _,0.00 15 .`_ ____0 0 . _- 0 273 -0 403 _^____0 0 ____T __0 0 0 0 . __- _ W -- _ . 13A-4ocs 13A-flocs y�-------- 2 glazing, cir low-e 0.143 ------0.143 0.650 a se ..__._4.00 se 4.00 0.00 2.19 _..._ _2.19'- - 0.00 0 --_-___0-0 0 0 0 0 ---- -. _0 0 0 0 0 0 -- - - ---0 0 0 -r.. --- 0 0 0 --- ---0 0 0 . --- _1 0 2 glazing, clr low-e 2 glazing, cir low-e 0.650 0.650 se se 18:20 18.20 23.35 23.35 0 0 0 0 0 D 0 0 D 0 0 0 0 0 0 0 -__-_ W 2 glazing, clr low-e .2glazing, _clnlow-e-_�-_ 13A-4ocs 0.650 ____0.650._ 0.143 se se s 0.00 _..18.20. 4.00 0:00 _24;74 2.19 0 __.__0-_._____0__._-__.0__.____0 0 0 0 0 0 0 0 0 ._- -------•--00. 0 0 0 0 0 0 _.__._0 0 -- 13A-flocs-_�,...- --- 2 glazing, cir low-e -- - _ --0.143 0.650 --sw sw ---- 4.00 18.20 �-- 2.19 17.79 --- - � 0 -- - --- - 0 0 __------ 0 0 ---- - -0 0 _ - -----0 0 -- - -- 0 0 - - -0 0 - - 0 0 2 glazing, clr low-e 2 glazing, clr low-e 2,glazi-g, clrlowe__ 0.650 0.650 _____0.65_.0 sw sw _sw._ 0.00 18.20 __ 0_.00 0.00 23.35 ___0.00 0 0 _ 0 0 0 0 0 0 ____0_0 0 0 0 0 ---- __--- 0 0 0 ,__0 0 0 0 0 _ 0 0 0 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11GO 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ _0.032 -_ - . _ _ 0.90: 1.60 -_ ._ _168 - -_ 168 151. _ _ 269 _35 _ __ 35.�-.._ _31 _._,_-_ 56 ---38.02-,__M0.00.__ 168---- 12 -- 456------0 6 c)AED excursion -71 -2 Envelope loss/gain 1300 831 31 54 12 a) Infiltration 162 46 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 1462 1837 31 54 Less e:Qemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 20 0 0 14 Subtotal 1474 1857 31 54 151 Ductloads 1 37% 53%1 551 990 37% 53% 12 29 Total room load 2025 2847 43 83 Air required (cfm) 97 123 2 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ��A -*- wright50ft' • 2017-Oct-25 0 Right -Suite® Universal 2017 17.0.08 RSU08101 Page ae 8 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 - wrightsoft' Right-JO Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 1 CLST 2 2 Exposed wall 6.0 ft 2.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 6.0 ft 60.0 ft2 10.0 x 2.0 ft 20.0 ft2 Ty ,Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-flocs 2 glazing, clr low-e 2 glazing, clr low-e - D.143 0.650 0.650 ne ne ne - 4.00 0.00 0.00 _._,__-2.19 0.00 0.00 _-__--._ f 60 0 0 60 0 0 240 0 0 131 0 0 20 0 0 20 0 0 80 0 0 44 0 0 11 2 glazing, cir low-e 2.glazing,_clr low_e-__ 0.650 _ _-- T 0.650 ne - ne- 18.20 ---0.00. 26.88 ----_ 0.00 0 . __ . _ . _0 0 ---- -- _0 0 _ _ - __ .9 0 __- _. -- -0 0 _ _ _- - _0 0 _- -- -- 0 0 -----_-- 0 0 - --_ __0 _--- _ W --- 13A-4ocs -_ _ _.. 13A-4ocs 2 glazing, clr low-e -- 0.143 0.143 0.650 --a- se se ---4.00 4.00 0.00 _---2.19 2.19 0.00 --- --.4 0 0 -- - -0 0 0 - --0 0 0 -- - -- 0 0 0 -_ _0 0 0 - --0 0 0 -- -- 0 0 0 - ----6- 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 18.20 18.20 23.35 23.35 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- W -- - - - 2 glazing, clr low-e 2.glazing,-clr_low-e 13A-4ocs -13A-flocs -"-- - --- 2 glazing, clr low-e 0.650 - 0.650.se 0.143 -- 0.143 0.650 se s --sw- sw 0.00 18.20.._24.74 4.00 - - 4.00 18.20 0.00 2.19 ---- 2.19 17.79 0 __0 0 --- - __0 0 0 - 0 0 0 0 - --0 0 - - --- -0- 0 0 - - 0- 0 -- -- - -- 0 0 0 --- 0- 0 --- --_0 0 0 - -,0-- - ---- 0 0 0 -- 0 0 ----- Q 0 0 - --0. 0 - - ---0 0 2 glazing, cir low-e 2 glazing, clr low-e _2.g(azing, clr low,e____ 0.650 0.650 w..___.Oai50 sw sw _wsw_ 0.00 18.20 _ _,0.00 _- '0.00 23.35 0 0 0 0 0 0 -____-___0 0 0 0 0 0 - ._._ _-0 0 0 •------ 0 0 0 0 _ 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11GO 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C -- -0.90 __. 1.60 _- _--- _ 60 _60 ------_54 --- - _ 96 _-- -,. 20 --. _-- --__20 -__ -_-__18..._ ._ 32 _224-t0h _ .1..358 c _-.38A2 __0.00 _----- _6P .. - _6 - -- --228 -- - 0 -- ----- 20 - - ---2 - - -76 - ___0_ 6 c)AED excursion -9 -3 Envelope loss/gain 522 218 174 73 12 a) Infiltration 81 23 27 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 603 241 201 80 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 210 95 -201 -80 14 Subtotal 813 336 0 0 15 Duct loads 1 37% 53% 304 179 37% 53% 0 0 Total room load Air required (cfm) 1116 54 515 22 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,A -ok wrightsaft' 2017-Oct-25 09:28:24 Right -Suite® Universal 2017 17.0.08 RSU08101 �� E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJB Front Door faces: SE Page 9 - - wrightsoft, Right-J® Worksheet Job: UNIT 1 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 2 3 Exposed wall Room height 12.0 ft 10.0 ft heat/cool 4 Room dimensions 11.0 x 12.0 ft 5 Room area 132.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ftf°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 - -, 134flocs -mV w '-0.143 ne -4.00 ~" 2,19 120 105 _P.____-_-_ 420 _-_ __---- 290 2 glazing,,clr low-e 2 glazing, clr low-e 0.650 0.650 ne no 0.00 0.00' 1 0.00 0.00 0 0 0 0 0 " 0 0 0 11 2 glazing, cfr low-e 2.glazi,pg, clr_lowce0.650 0.650 ne _.ne- 18.20 ___0 .00-.,_.n.0;00 . 26.88 15 0 273 403 w--- _13A-4ocs 13A ocs 2 glazing, clr(ow-e , 0.143._e,-._._.. 6.143 0.650 se se . 400 4.00 0.00 _. 2.19.__ 219 0.001 ....__9 0 0 9 0 0 _- 0 0 0 _-____._ 0 0 - -LG' 2-glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 18.20 18.20 23.35 23.35 0 0 0 0 0 0 0 0 _._w_ .':2.glazing,-clr 2glazing, clrlow-e low=e�-- 0.650 _ 0.650 se _se_ 0.00 ___18.20 0.00 !_ __24.74 '0 :,_ _ 0 0 ____0 0 0 N W ---- 13A-4ocs 13A-4ocs�_____�____; 2 glazing, clr low-e 0.143 0:143_sW_ 0.650 s sw 4.00 -4:00 18.20 2.19 '-'--2:19 17.79 0 0 0 �.._0 0 0 0 O 0 _..:.Zgt 2 glazing, clr low-e 2 glazing, clr low-e ng, dr low-e __, 0.650 0.650 __ ._0.1550 sw sw ,_sw' 0.00 1&20 __-, MQ, 0.00 23.35 _ .. 0;00 0 0 _...__0 0 0 .__ _ 0 0 - 0 __ ___ -0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 0.00 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11G0 0.650 0.540 nw nw 0.00 15.12 0.00 14.31 0 0 0 0 0 0 0 0 _ w _ 22A-ti3h__;_, m_. _1.358 _ .._ _38.02 0.00 132 ___12 -__,_. 456 6 c)AED excursion -69 Envelope loss/gain 1268 775 12 a) Infiltration 162 46 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 2 460 Appliances/other 500 Subtotal (lines 6 to 13) 1430 1782 Less external load 0 0 Less transfer 0 0 Redistribution 119 72 14 Subtotal 1549 1853 15 Duct loads 37% M%j 579 989 Total room load 2128 2842 Air required (cfm) 1 021 123 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -� wrightsc ft- 2017-Oct-25 09:28:24 ACC 6. RightSuite® Universal 2017 17.0.08 RSU08101 Page 10 E:\Documnets\Wrightsoft HVAC\ALMORE R ESI D ENC E. rup Calc = MJ8 Front Door faces: SE -- wrightsoft9 Right-J® Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area UNIT 2 206.0 ft 10.0 ft 1514.0 ft' BATH 2 2.0 ft 10.0 ft heat/cool 1.0 x 105.0 ft 105.0 ftz Ty Construction number U-value (Btuhlft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - 13A-4ocs - - - 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2,glazing, clr lower.-.. 13A_4ocs-- ----- 13A-4ocs 2 glazing, clr low-e 2 glazing, clrlow-e 2 glazing, clr low-e - 2glazing, clr low=e 2.glazing, clr low-e--- 13A-4ocs I-8- 6s- - ---... -- 13A�ocs 2glazing, clrlow-e 2 glazing, clr low-e 2 glazing, clrlow- 2gl_azing, drLpwe 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 11GO 22A_tl)h--- - -0.143 0.650 0.650 0.650 --_.-0.650 --0.143 0.143 0.650 0.650 0.650 0.650 -----0.650 ---- 0.143 0.143 0.650 0.650 0.650 0,650 0.143 0.650 0.650 0.650 0.540 ne ne ne ne _,ne_ e_ se se se se se _se _ s -- sw sw sw sw _sw nw nw nw nw nw 4.00 0.00 18.20 0.00 __18.2Q -- -0.00 4.00 0.00 18.20 0.00 18.20 -.._0.00, 0.00 ---- 6 4.00 18.20 0.00 0.00 _._ 18.20 4.00 0.00 18.20 18.20 0.00 _ _.. ----38,02 - 2.19 0.00 26.88 0.00 __26.88 0.00 2.19 Q00 23:35 0.00 24.33. -._ _- 0.00 0.00 -Al-- 2.19 17.79 0.00 0.00 _-24_33.._____- 2.19 0.00 26.88 26.88 0.00 480 0 12 0 _41 - 0 540 0 45 0 20 ---------0 - --- 0 480 6 0 0 560 0 36 48 --_. 0 1514 --- - 427 0 0 0 -------__0 - 0 475 .0 14 0 5 --- - - -- 0 _ 0 5- - 454 5 0 0 476 0 0 0 0_ 206 1711 0 218 0 ------743 -0 1900 0 819 0 371 -------- 0 0_ 18 1816 109 0 0 1906 0 655 874 0_ _�1357 7833 - - -- 935 0 323 0 -._-. 1097 - - 0 1038 0 1051 0 496 - -- -----0 --- 0 992 107 0 0 1041 0 968 1290 0 .__.2422�_105. -- - 20 0 0 0 - ----- - --- 0 0 0 0 .0 0 --- ----_0 0 -- 0 0 0 0 0 0 0 0 0_ - 20 0 0 0 .------0 -- - 0 0 0 0 0 0 -----0 0_ - 0 0 0 0 0 0 0 0 0 80 0 0 0 -----0. -- 0 0 0 0 0 --- --_ -0 --- 0_ 0 0 0 0 0 0 0 0 - 44 0 0 0 `--_-0 .0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 _ __.. ____ _ _ 0 - W _..-- - W - - - F -- _ 32 0.0320.90 _._ _ 1.358 -- ---_ T- 60 _-__1,60__-_151.4.-�1514 _ 0.00 _ .105 __105 - 2 `_94168- ----- 76 - -0 6 c)AED excursion 110 -41 Envelope loss/gain 20683 12366 250 171 12 a) Infiltration b) Room ventilation 2779 0 798 0 27 0 8 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 2800 0 0 300 Subtotal (lines 6 to 13) 23462 15964 277 479 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 18% 38% 0 0 0 23462 4303 0 0 0 15964 6067 18% 38% 0 0 0 277 51 0 0 0 479 182 Total room load Air required (cfm) 27765 967 22030 967 328 11 661 29 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A& wrightsoft' 2017-Oct-25 09:28:24 Right -Suite® Universal 2017 17.0.08 RSU08101 .4C�A E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 11 - wrightsoft, Right-M) Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@}10L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M WIC 2 U2 O ft 10.0 ft heat/cool 5.0 x 6.0 ft 30.0 ft2 M WIC 1 U2 O ft 10.0 ft heat/cool 5.0 x 6.0 ft 30.0 ft2 Ty Construction number U-value (Btuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 ��- 13A flocs - �- - 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr.low-e -2,glazing,_clr low -a-.._. 13A-0ocs------- - 13A-4ocs 2 glazing,. cir low-e 2 glazing, clrlow-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr_low-e___ 13A-4ocs 13A�ocs _ ____- -- 2 glazing, clr low-e 2 glazing, clr''low-e 2 glazing, clr low-e _.glazing,.bIr low-e-_ 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 11G0--- -- - - 1613_30ad-_-- 2267tPh-_.-_-.___ - - 0.143 0.650 0.650 0.650 ______0.650 - - 0.143 0.143 0.650 0.650 0.650 0.650 _ ___.0.650 0.143 - - - 0.143 0.650 0.650 0.650 _---_0,650 0.143 0.650 0.650 0.650 --0_540 - 0,032 1.358 ne ne ne ne _ne-, - e - se se se se. se ,_se s sw sw sw sw sw nw nw nw nw nw -:- 4.00 0.00 18.20 0.00 __--18 20 - 0,00 4.00 0.00, 18.20 0.00: 18.20 _ -- 0.00 0.00 -- 4.00 18.20 0.00 0,00 ___ 18.20 4.00 0.00 18.20 18.20 .- _000 -----0.90 _-_38.02 2.19 0.00 26.88 0.00 _.__26.88 ___ 0'Q0 2.19 0.00 23.35 0.00 24.33 _--_-0.00 0.00 - 2.19 17.79 0.00 0.00 --_•24.33 2.19 0.00 26.88 26.88 0.00 1.60 _-0.00 0 0: 0 0 -----0 0 0 0 0. 0 0 -_--__-- 0 0 --------0 0 0 0 .______ 0 0 0 0 0 - - -0 _ --- -30 __-._-. __30 _-_...._______--- 0 0 0 0 ------ 0 -- -- - 0 0 0 0 0 0 ---_ ---_0 0 ------0 0 0 0 _ ._--=- 0 0 0 0 0 - 0--- -_-- --- 30 _-_____-.0 0 0 0 0 -------0 - - 0 0 0 0 0 0 _ - ___0 0 ---- -- _0_ 0 0 0 -- __-__ 0 0 0 0 0 - 0.. - -__-2Z 0 -_-_. __ 0 0 0 0 ---- -0 -- -- _0 0 0 0 0 0 --- -----0 0 -- ------ -0- 0 0 0 0 0 0 0 0 ,---- _48 ____ _--- 0 0 .0 0 .--.------0 - - --0 0 0 0 0 0 _- __ - --0 0 ----- _0 0 0 0 0 0 0 0 0- :_. - .__ 30 _ ._ -.30 0 0 0 0 -- - ----0 ---- -- - 0 0 0 0 0 0 _ _ - 0 0 - -----Q 0 0 0 0 0 0 0 0 _-----30 -0 0 0 0 0 ----- _0- - -- -0 0 0 0 0 0 -_.-- _0_0. 0 0 0 0 0 0 0 0 ----0 ----27 •-_-----0 0 0 0 0 - -- --- 0- - --0 0 0 0 0 0 6 -0 0 0 0 --- _ .W W . _ ___. 0 0 0 0 -- 0 _ _ ___ 48- _-.._-_0 _- _C_.__- F _ _L_ -_0 6 c)AED excursion -4 -4 Envelope loss/gain 27 44 27 44 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 127 44 27 44 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 18% 38% 0 0 0 27 5 0 0 0 44 17 18% 38%1 0 0 0 27 5 0 0 0 44 17 Total room load Air required (cfm) 32 1 61 3j 1 32 1 61 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -4d" wrightseft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09:28:24 .400A E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 12 -�- wrightsoftRight-J® Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name ENTRYU2 LAUNDRYU2 2 Exposed wall 24.0 ft 9.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 10.0 ft 100.0 ft2 9.0 x 4.0 ft 36.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 ne ne 0.00 118.20 0.00' 26.88 100 0 0 86 0 0 319 0 0 174 0 0' _- - Q 0 0 0 0 0 0 0 0 11 _ - __ : 2 glazing, cIr low=e _2.91azing„ clr_low-e___ 0.650 ___-0.650 ne _-ne_. 0.00 _ _ 18.20, 0.00 _26.88 • 0 ____20 0 ._._._,.. 9'___.._._371, 0 0 _._._._.._548 0 __.____0 0 . ____.:A 0 ___ .__-_0 1 0 ___.___ 0. 13A flocs 2glazing, clrlow-e 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 0.650 se se se se 0.00 - 4.00 0.00 18.20 0.00 2:1 g 0.00 23:35 o.00 -- 80 0 0 0 80 0 0 0 320 0 0 0 175 0 0 0 0 90 0 0' 0 _- __ 0 90 0 0 0 0 360 0 0 0 - -- - 0 197 0 0 0 . _,- . W 2glazing, clrlow-e 2 glazing,._clr_low_-e._,._..__._. 13A-flocs _ 13A-flocs 2 glazing,'clr low-e. 0.650 _0.650 _ 0.143 0.143 0.660 se '-se- _ s _ sw sw 18.20 __0.00 0.00 _ _ry 4.00 18.20 24.33 M 0.90 0.00 2.19 17.79 0 _ _ _ 0 , 0 60 0 0 _._._ _._0 _ _ 0 60 0 0. . -.__ ..- 0 0 _ 240 0 0 ._._ Q 0 ----_-- 131 0` 0 _ _ __. 0 0 __-__. 0' 0 '--_ -- --__ 0 0 _ _T _- 0 0 0 0 0 0 ---- 0 0 ----__--- 0 0 2 glazing, clr low-e 2 glazing, clr low-e .2 glazing,_glr low4e _._ 0.650 0.650 _ __.___ 0.650 sw sw $X . 0.00 0.00 .__ 18, 20 0.06 0.00 ,_-_24.33 0 ' 0 N_n _n0 0 0 '.r_ _ -. Q 0 0 :.: _.___ _0 0 0 __.� _.. _0 0 0 _ _ 0 0 0 _ 0 0 0' __ _ 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 18.20 2.19 0.00 26.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 2 glazing, clr low-e 11GO 16B 30ad._ _ ._ 0.650 0.540 --. -_0.032 nw nw _. 18.20 0.00 _0'90: 26.88 0.00 ,___ 1.60 0 0 _..� _360 0 0 __, 900 0 0 0 0 0 0 0 0 0 0 0 0 ____._ 1.358 _ _ - 38.02 __- _0.00 _ r _.-._342 6 c)AED excursion -100 -62 Envelope loss/gain 2253 1088 735 193 12 a) Infiltration 324 93 121 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 2577 1181 856 727 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 146 46 14 Subtotal 2577 1181 1003 773 15 Duct loads 18% 38%1 4731 449 1 8%1 38% 184 294 Total room load 3049 1630 1 1187 1067 Air required (cfm) 106 72 141 47 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 Pag lak e 13 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 -�- wrightsoft° Right-M Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@/10L.COM 1 Room name HALL U2 NOOK U2 2 Exposed wall 5.0 ft 17.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 4.0 ft 20.0 ft2 10.0 x 12.0 ft 120.0 f12 Ty Construction U-value Or HTM Area (ft) Load Area (ft-) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs - 2 glazing, clr low-e 2 glazing, clr low-e 0.f 0.650 0.650 ne _ ne ne _ _.-4:00 0.00 18.20 .__ 2:19 0.00 26.88 -_-._. ;-b 0 0 - ____ 6 0 0 .___ .----0 0 0 ------ - •--0 0 0 _-__-_ .0 0 0 --- -_. _---0 0 0 .____ ---0 0 0 -__ 0 0 0 11 2 glazing, clr low-e 2.glazing, dr.low a--- 0.650 ----0,650 ne _ ne- 0.00 ---18.20. 0.00 _ __.26.88 0 ---- �. 0 0 __ __0 0 _,.-----0 0 ___ _ -__-0 0 --__ 0 0 --- -----9 0 ---- -0- 0 --__-0 _--- _ w -- 13A-4ocs -� 13A flocs 2 glazing, clr low-e 0.143 0.143 0.650 e se se - 0.00 4.00 0.00 0,00 2.19 0.00 0 50 0 0 50 0 200 0 109 0 0 0 0 0 0 0 0 0 2 glazing,, clr low-e 2 glazing, clrlow-e 0.650 0.650 se se 18.20 0.00 23.35 0.00 0 0 0 0 0 0 0 0 '0 0 A 0 0 0 0 0 _-- -- _ W 2 glazing, clr low-e -2.glazing,_clr low-a-.--. 13A-4ocs 0.650 ----0..650 0.143 se se_ s 18.20 0.00 24.33 0.00 0.00 0 .0 0 0 --_----_0 0 0 - ------0 0 0 --- ------0 0 0 _-----0 0 0 - -.------0 0 0 --------0 0 0 -- - --0 0 -- - - - -- 13Aflocs 2 glazing, clrlow-e - 0.143 0.650 sw sw - 4.00 18.20 2.19 17.79 ' --- - ---0 0 - 0 0 - - --0 0 - - -0 0 --- 70 0 - - - - 50 0 - -- 199 0 - -- -109 0 L-G- _ 2 glazing, clr low-e 2 glazing, clr low-e 2.glazing,_cl� low^e,--_ 0.650 0.650 ----9650 sw sw sw 0.00 0.00 ___18.20 0.00 0.00 ...24.33 0 0 - 0 0 0 _0 0 0 _._. - :..0 0 0 �.___0 0 0 _--___20 0 0 _.-__ 5 0 0 _371- 0 0 _ __ 496 352 0 218 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 18.20 2.19 0.00 26.88 0 0 0 0 0 0 0 0 0 0 0 0 100 0 12 88 0 0 193 0 323 2 glazing, clr low-e 11GO 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _C_ _ __ _16B-30ad___.___^ _-_-0.032 __ _ -_-___0.90 38.02 6 c)AED excursion -13 164 Envelope loss/gain 408 129 1895 1476 12 a) Infiltration 67 19 229 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 200 Subtotal (lines 6 to 13) 476 148 2124 1742 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -476 0 0 -148 0 0 0 2124 0 0 1742 151 Duct loads 18% 38% 0 0 18% 38% 390 662 Total room load Air required (cfm) 0 0 0 0 2513 88 2404 106 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. '� wright60ft" Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09:28:24 �� E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 14 -t- wrightsoft° Right-J® Worksheet Job: ` UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER U2 DINING ROOM U2 2 Exposed wall 5.0 ft 26.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 ft2 12.0 x. 12.0 ft 144.0 ft2 Ty Construction number U-value (Btuh/ftz °F) Or HTM (Btuh/ftz) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 _._ 13A-4ocs _0.143 _. neJ 4.002.19 0 0 0 0 80 80 320 175 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 ne ne 0.00 18.20 0.00 26.88 0 0" 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 2_glazing,_clrlowue___ 0.650 __0.650 ne' _,ne_ 0.00 J,8.2Q,___2688 0,00 0 __ 0 0 ._ m 0 0 __.__ 0 0 _ _ _ _0 0 0 0 _ _._--0 0 _----_Q 0 _.___a.�Q v_...__� 65 0 W _ _ " 13A-4ocs_ ,. '13A-4ocs 2 glazing, clr low-e -_ _a 0.143 0.143 0.650 e_. se se _ 0.00 4.00 0.00 _0.00 2.19: 0.00 0 50 0 0 _. 30 0 _ _ _.. Q 119 0, Q 120 0 0 90 0 _ _ _. 0. 360 0 __0. 197 0' 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 se se 18.20 0.00 23:35 0.00 '` 0, 0 " 0 0 0 0 0 0 30 0 9 0-` 546 0 700 0 2,glazing, cir low-e 2,glazing, clr_low-e-_-'._____0:650 0.650 se _se 18.20 _ . O.OQ - 24.33 _ __ 0,00 20 _0 5 ..,,_...1_._ 0 371 '_.-_______0 496 0 0 '. 0 0 W 13A-flocs ._ ._ 13A-flocs 0.143 ___ __. _ -0. 0.143 s sw 0.00 4.00 0.00 .2.19 _ 0 0 0 .. _ _ __. 0 __. _ 0 0 0 __.. _ 0 _ 0 60 0 60 0 --- 240 - 0 131 2 glazing, clrlow-e 0.650' sw 18.20 17.79 ., 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cir low-e 2.glazing, dk_lovLe_ _-_ 0.650 0.650 9 50 sw sw aw_ e 0:00 0.00 _ 18.20_ 0.00 0.00 a_243.3. 0 0 0 0 0 _._.__0: 0 0 _ _Q--_____=Q 0 0 0 0 0 0 0 0 _ 0 0 0 0 0 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 18.20 2.19 0.00 26.88 0 0 0 0 0 0 0 0 0 0 0 0 0 ( 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11GO 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ,16B__30ad_ _ _ 0 032 _. _._�0.90 1.60 _30 . 30 __ 27 ___.48 _ __144 .a_�_.__1.44 ___- 129 _ _230 _1.358 _38.02, ____ 0 00 _____,30 ______._,._5 -- 190 ____.0 _ _ �44 . 26 989 6 c) AED excursion 103 95 Envelope loss/gain 707 712 2585 1529 12 a) Infiltration 67 19 351 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 774 731 2935 1630 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -774 -731 420 304 14 Subtotal 0 0 3355 1933 151 Duct loads 18% 38% 0 0 18% 38% 615 735 Total room load 0 0 3970 2668 Air required (cfm) 01 0 138 117 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. C "'Pk- wrightsoft' 2017-Oct-25 09:28:24 Right -Suite® Universal 2017 17.0.08 RSU08101 �� Page 15 EADocumnets\Wrightsoft HVACIALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE -�- wrightsoft° Right-J® Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FAMILYROOM'1.12 BEDROOM 6 2 E)posed wall 14.0 ft 11.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 339.0 ft 339.0 ft2 11.0 x 11.0 ft 121.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 2 glazing, clr low-e 2 glazing,, cir low-e 0.650 0.650 ne ne 0.00 18.20 0.00 26.88 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 2.glazing, clr IQW-e.__ 0.650 ____0.650 ne _Re - 11 0.00' ___ %20 0.00 ._.-._26.88 : 0 _ ,_0 0 _v _0 0 0 0 -_ �:.__..0 0 _ 0 0 _s _._,__.-0 0 __,_._--A0- 0 W__._ _13A4ocs 13A-0ocs 2 glazing;,cir low-e ____ 0,143. 0.143 0.650 a se se ___.0.00, 4.00 0.00 _. 0.00 2.19 0:00 ___,� 0 0 0 __..- 0 0 0 0 0 0 -__ _- v0 0 0 _0 116 0 A 95 0 --_.��0 380 0 0 208 0 2 glazing, cir low-e 2 glazing, clr low-e 0.650 0.650 se " se • 18.20 0.00 23.35 0.00 0 0 0 0 0 0 0 0` 15 0 - 5 0 273 0 350 0 _ _ W _.. 2 glazing; cir low-e :2.glazirig, clr love 13A-flocs _ _ - _. 73A-flocs `0.650 �___ o.8$0 ._ 0.143 0.143 se _se. s _ __ sw 18.20' _ . ,0 00 0.00 400; 24.33 _0.00 0.00 "���2:19 0 . _ _ _._0 0 -0 0 -"--0 0 -'' � ` 0 0 __.__--o 0 - � 0 0 � ._ ._ 0 0 _ - -_. -. _ _ � � 0 0 _ - 0' 0 ..__ _ , 0 0 _0 0 .__ _ -- -._. 0 0 -_-0- 0 _. ._ -- 0 0 � __Q 0 _ -.� _.__. 0 2 glazing, clr low-e 0.650 sw 18.20' 17.79 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cGiow-e 0.650 0.650 sw sw 0.00 0.00 . 0.00 0.00 0 0 0 0 0 0 0 0 0 .6 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 18.20 2.19 0.00 26.88 140 0 0 92 0 0 368 0 0 201 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11GO ____�__-_... ______ _ 18B 30ad,_ _ .,_,_ 0.650 __ ._. 0_._540 _ 0032 nw nw 18.20 _ 0.00 26.88 0.00 48 _ 0 0 _ 0 874 0 304 1290 0 _ .--_-542 0 0 __... _ _ 121 0 _ 0 0 0 _ 0 0 __. _Yt F -__- -22A-tph,_,,___ - _ 1.358 _ 38.02 --0.00 339 14 _ 532 0 121. 11 _ 418 0 6 c)AED excursion 160 22 Envelope loss/gain 2078 2194 1180 773 12 a) Infiltration 189 54 148 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 900 300 Subtotal (lines 6 to 13) 2267 3148 1328 1116 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 431 279 1297 547 14 Subtotal 2698 3428 2626 1663 15 Duct loads 18% 38% 495 1303 18% 38% 482 632 Total room load 3192 4730 3107 2295 Air required (cfm) 111 208 108 101 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. WPight50ft' RightSuite@ Universal 2017 17.0.08 RSU08101 2017-Oct-25 Pa09:ge 16 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 -�- wrightsoft, Right-M Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area CLST 2A 13.0 ft 10.0 ft heat/cool 2.0 x 11.0 ft 22.0 ft2 BATH 3 5.0 ft 10.0 ft heat/cool 9.0 x 5.0 ft 45.0 ft2 Ty Construction number U-value (Btuhfftz °F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e lower---- 13A-0ocs - - -- - 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing,, clr low-e 2 glazing, clr low-e 2.91azing,.cir low e - 13A4ocs 13A4ocs -- -- --- 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e ,2 glazing,-cir low e! 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 11G0 22Atph ------ 0.143 0.650 0.650 0.650 , -6.650 -- 0.143 0.143 0.650 0.650 0.650 0.650 - 0.650 0.143 - - - 0. f 43 0.650 0.650 0.650 -..- Q,650 0.143 0.650 0.650 0.650 0.540 -- _1.358 ne ne ne ne _.ne_ --e se se se se se _se- s sw - sw sw sw _sw- nw nw nw nw nw - 4.00 0.00 18.20 0.00 __18.20, -0.00 4.00 0.00 18.20 0.00 18.20 - - 0.00 0.00 -- 4.00 18.20 0.00 0.00 _-- 15.20 4.00 0.00 18.20 18.20 0.00 -_. 0.90..---- _._ 38.02 2.19 0.00 26.88 0.00 -----26.88 .. _ 0.00 2.19 0.00 23.35 0.00 24.33 _._-0.00 0.00 - - 2.19 17.79 0.00 , 0.00 ---24.33 2.19 0.00 26.88 26.88 0.00 1.60 --•-0,00 0 0 0 0 ------Q - - 20 0 6 0 0 - -0 0 ' - 110 0 0 0 -0. 0 0 0 0 0 ---.--.22 _ .. ----22 ----. 0 0 0 0 --- -Q - - - 20 0 0 0 0 - -- _0 0 -- - 110 0 0 0 ,-.- -- 0 0 0 0 0 0 ___ --- -22 __13 --_.-._ ---- 0 0 0 0 - - _,_0 -- -- -0 80 0 0 0 0 _ -- -- 0 -- 440 0 0 0 __. 0 0 0 0 0 0 ---.-20 _---494 0 0 0 .-_ ^0 - - - 44 0 01 0 0 - - - 0 0 - - 241 0 0 0 0 0 0 0 0 0 _ .__. -35 --- -0 0 0 0 _ �.--0 - 0 0 0 0 0 - - _0 0 --- --50 6 0 0 _ --Q 0 0 0 0 0 -..-__.--45 0 0 0 -_---- -0 - - -0 0 0 0 0 0 ------- 0 0 ' -- 4-4 5 0 0 -- ---_0 0 0 0 0 0 --- 45 _--5 0 0 0 - --_0- •_-. - 0. 0 0 0 0 0 - ---0- 0 --- - 176 109 0 0 0 0 0 0 0 0 -- 40 _ 190 0 0 0 --- 0 - ___._ _ 0 0 0 0 0 0 - - 0 0 - -- 96 107 0 0 ----0 0 0 0 0 0 -----^72 _ 0 ..2.glazing,_clr W ---- - --.: W - -- _ E- - --45.._- 6 c)AED excursion -29 38 Envelope loss/gain 1035 291 516 313 12 a) Infiltration b) Room ventilation 175 0 50 01 67 0 19 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1210 341 683 333 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 1 18% 38% 0 0 -1210 0 0 0 0 -341 0 0 18% 38% 0 0 276 859 158 0 0 86 419 159 Total room load Air required (cfm) 0 0 0 0 1017 35 578 25 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. ��A ' WPigF7t50ft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 g Page 17 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE - wrightsoft° Right-J® Worksheet Job: UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST 3A BEDROOM 7 2 Exposed wall 2.0 ft 30.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 2.0 ft 18.0 ft2 12.0 x 11.0 ft 132.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load number (Btuh/ft�- °F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-flocs 2 glazing, clr low-e 2 glazing, clr low-e 0,143 0.650 0.650 ._.-_ne. ne ne 4.00 0.00 18.20 2.19 0.00 26:88 - 0 0 0 0 0 0 -- 0 0 0 4Y--- - 0 0 0 �70' 0 0 70 0 0 280 0 0, 153 0 0 11 __- _..2.glazirig,_clr 2 glazing, clr low-e low e 0.650 --_0,650 ne _ne_ 0.00 _-_.18.20. 0.00 0 0 0 0 0 .-._0 0 --_0 0 ----._.__0_ 0 _0 _..13A-4ocs._-__ _. _.- 13A-0ocs 2 glazing, clr low-e ---.-__0143 0A43 0.650 __e se se _ 0.00 4.00 0.00 . _. Q_0o 2.19 0.00 _ - 0 0 0 ._ 6 0 0 _.___-----_0 0 0 - -._ w --0 0 0 -- -- Q 0 0 _ ----- 0 0 0 ------__Q 0 0 _ -_ _0. 0 0 2 glazing, cir low-e 2 glazing, clr low-e 0.650 0.650 se se 18.20 0.00 23.35 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W _ _ 2 glazing, cir low-e 2,gl_azing,.clrlow,e__-: 13A-4ocs __ _. 2 glazing, cir low-e 0.650 -_-__- 0.650 0.143 __ ..- 0.143 0.650 se _-se.-. s -sw- sw 18.20 _. _0.00 0.00 .__ 4.00 18.20 24.33 ____._0.00 0.00 - _-_ x2.19 17.79 D ,_. 0 0 0_ 0 0 _ 0 0 _._ ___ .20 6 0 _,_._- _ 0.__.._._ 0 _._ .__ __ 80 0 0 -_0 0 .--_ ._ � 0 0 -_.. _ _ 0...-_ 0 ._._ _ ... 110 0 0 _0..__ 0 -----110 0 0 _-- 0 0 a". _ 440 0 0 __-.--.__.0 0 -- -- 241 0 _ 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing,_clr low e_ 0.650 0.650 0.650 sw sw ,_sw_ 0.00 0.00 w_18.20 0.00 0.00 -__2433 0 0 __ 0 0 0 .__ __._.-. _0 0 0 .__._ _. �0 0 0 _ __0 0 0 . __ .__.u0 0 0 ...__. _._ 0 0 0 0 13A4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 0.00 18.20 2.19 0.00 26.88 0 0 0 0 0 0 0 0 0 0 0 0 120 0 12 108 0 0 432 0 218 236 0 323 2 glazing, clr low-e 11G0 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 __-- -- - ,216E-30ad__-_ ._._ _ 0 032 _ .. _0.90:. 1 60 _n _ 18 _ _ -_.18 _ . _ , 16 .0 _ ._29 _._ . _...._ ____132 --._ _.. __... _ 132 _0 ______ 118. _._ ____211 F__....22A-tph. ,.1.35838.02.._.__0,00 18__..._...__-2 .7.6 __0132301141..._ 61 c)AED excursion -6 -21 Envelope loss/gain 11721 66 2631 1142 12 a) Infiltration 27 8 405 116 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 300 Subtotal (lines 6 to 13) 1199 74 3035 1559 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -199 -74 90 33 14 Subtotal 0 0 3125 1592 15 Duct loads 18% 38% 0 0 18% 38% 573 605 Total room load 0 0 3698 2197 Air required (cfm) 0 0 129 96 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � � oft ,wrights' 2017-Oct-25 09:28:24 Right -Suite® Universal 2017 17.0.08 RSU08101 �� E:\Dccumnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Cale = MJ8 Front Door faces: SE Page 18 -�- wrightsoft° Right-J® Worksheet Job: ` UNIT 2 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax: 772.466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 6 17.0 ft 10.0 ft heat/cool 6.0 x 9.0 ft 54.0 W BEDROOM 5 26.0 ft 10.0 ft heat/cool 14:0 x 12.0 ft 168.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2-glazing, clrlow-e-_ 13A-4ocs -- - . . - - -- - - 13AAocs 2.glazing, clr low-e 2 glazing, cir low-e 2glazing, clrlow-e 2 glazing, clr low-e 2.glazing, clr-low-e_ 13A-4ocs 13A-4ocs - - - - ----- 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing;, cir low- .2glazing,_c1r_I -e-_- 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 11GO _ - ... - -- 16B730ad- -- -_--- _ -- 0.650 0.650 0.650 _ 0 850 - -0.143 0.143 0.650 0.650 0.650 0.650 0.650 0.143 7, --6.149 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 ---- 0.540 -- --_ 0.032 _--_-1.358 ne ne ne __ne_ a se se se se se - _ se_ s sw sw sw sw sw nw nw nw nw nw, _-- 0.00 18.20 0.00 _ 18.20 0.00 -- 4.00 0.00' 18.20 0.00 18.20 -- __0.00- 0.00 4.66 18.20 0.00 0.00 _ -18.20 4.00 0.00 18.20 18.20 -- 0.00 --- 0.9.0- _v. 38.02 0.00 26.88 0:00 _-_ 26.88 _ 0.00 2.19 0.00 23.35 0.00 24.33 _. _0.00. 0.00 -- - 2.19 17.79 0.00 0.00 _-24.33 2.19 0.00 26.88 26.88 - 0.00 --_ 1.60 __ 0.00, 0 0 0 0 ___20 0 ` - -- 26 0 0 0 0 0 0 --..---0 0 0 0 70 0 0 0 __- _-._0 0 - - 20 0 0 0 0 ___O 0 - - -_b 0 0 0 --_ _ 9 60 0 0 0 - - 0 ---- 54 . --•- --- 17 279 0 0 0 _____37-1 0 _ 80 0 0 0 0 --- -____O 0 -----0 0 0 0 - -- � 240 0 0 0 -- - 0 --- --- 48 ----646 152 0 0 0 _ ____548 0 - - 44 0 0 0 0 ._ _ 0 0 -- -_-0 0 0 0 --__--0. 131 0 0 0 -- -- 0 -- ____86 120 0 12 0 __- 0 0 108 0 0 0 _- 0 0 --- - _0 0 0 0 0 . - -- _-- 0 0 0 0 0 -___- 0 128 0 0 0 _ -- 0 _168 26 432 0 218 0 _ 0 0 -- - -0 0 0 0 0 _-- 0. y - 0-- 0 0 0 ------ - 0- 513 0 218 0 --- - 0 -- _-_151 - _989 236 0 323 0 0 - _ 0 0 0 0 0 __ __-- -0 0 0 0 0 ---.---A 280 0 323 0 -- - - 0 .._--._-_269 _-----_0 . W - -- - 0 0 0 0 0 _ ._.__ ... 0 0 0 0 0 --- ---Q 140 0 12 0 -0 - ------- 168 _-_ - 168 ---__ - W ___._-0 60 0 0 0 -- - - 0 _- .__-54 --- 54 - -- __ __. ----___0 6 c)AED excursion -81 -112 Envelope loss/gain 1665 881 2521 1318 12 a) Infiltration b) Room ventilation 229 0 66 0 351 0 101 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 300 Subtotal (lines 6 to 13) 1894 947 2872 1719 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 18% 38% 0 0 0 1894 347 0 0 0 947 360 18% 38% 0 0 0 2872 527 0 0 0 1719 653 Total room load Air required (cfm) 2242 78 1307 57 3398 118 2372 104 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrightsaft" Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09:28:24 .4C Page 19 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE -�- wrightsoft° Right-J® Worksheet Job: ` UNIT 3 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name UNIT 3 BEDROOM 9 2 Exposed wall 176.0 ft 30.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 1372.0 ft2 12.0 x 11.0 ft 132.0 ft2 Ty Construction number U-value (13tuh/ft2--°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A113ocs 2 glazing, clr low-e 2 glazing, clr low-e .._..__0143` 0.650 0.650 ne___ ne ne .4.00 18.20 0.00 2.19 26.88 0.00 _.410 6 0 384 0 0 T1536 109 0 839 161 0 110 0 0 110 0 0 440 0 0 241 0 0 2 glazing, clr low-e 0.650, ne 0.00 0.00 0 0 0 0 0 0 0 0 11 _.2 glazing, clrlQw-e__._ _,__,__Q.6.50 _ne .__18.20. -26.88 _.20 _.. 0 _w 371. �r 548 .__,_.___..., 0 __.-..._0 __-_ _ -0. 0 0 W .___.. 13A-4ocs 13A flocs. 2 glazing, cir low-e __.0.143 0.143 0.650 _ e se se 0.00 4.00 18.20 _,__, 0.00 2.19 27:05 _0 ' 440 65 0 375 0 0 1500 1190 -__ _ _._ __0 820 1769 ._.- ____.0 0 0 _ __ . 0 0 0 - ------ Q 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 0.00 0.00 0.00 0.00 0 0 0 0 - '0 0 0 0 0 0 0 0 0 0 0 0 W _ 2 glazing, clr, low-e ,2.glazing„ clr low.._ 13A-4ocs 13A��ocs; ` 2 glazing, clrlow-e 0.650 __0.650. 0.143 ..--0.143 0.650 se se s -sw sw 0.00 0.00 V 4.00 0.00, 0.00 0.00 - � 2.19 0.00 0 0 �--.-,, 410 0 0 0 � - -_ �390 0 0 _--_-..-__ 0 0 �._ _1360 0 0 _.-__ ..-_0 0 ._._ _.. 852 0 0 _____ __._0 0 10 0 0 -._-._.._-0__0. 0 .__._ _._ i0 0 0" 0 280 0 0 _-._ __ 0, 0 153' 0 u _ _ 2 glazing, clr low-e 2 glazing, clr low-e :2_glazing, c(r_low_e _ 0.650 0.650 sw sw -sw 18.20 0.00, __-_ 0.00 27.05 0.00 000 - 20 0, 0 0 0 __0 371 0 552 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 500 36 0 416 0 0 1666 655 0 910 968 0 120 12 0 108 0 0 432 218 0 236 323 0 2 glazing, clr low-e 11GO 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 48 0 0 0 874 0 1290 0 0 0 0 0 0 0 0 0 C _ _16B-30ad_,.__.n..__.- - ___ 0 032 __-v ; _-0.90 ._ 1 60 _1 .w1372 __._. 1372 -_..__1229 a.__. 2195 __.._ -_._132 __ __132 _ 118 ___211 .22A-tph--,_ ._ _. 1•.358 38,02 0,00 V-- 1.372 176 ___- 6692 m 0 __132 ______30 ____- 1141- __0 6 c)AED excursion 01 24 Envelope loss/gain 17754 10905 2631 1188 12 a) Infiltration 2375 682 405 116 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 4500 200 Subtotal (lines 6 to 13) 20129 16776 3035 1504 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 90 34 14 Subtotal 20129 16776 3125 1538 15 Duct loads 20% 34% 4052 5733 20% 349/o 629 526 Total room load 24180 22509 1 3754 1 2064 Air required (cfm) I967 967 150 89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .4CCK -�- WrGght50ft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 Page 20 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE -- wrightsoft Right-J® Worksheet Job: ` UNIT 3 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS @t. 40L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BEDROOM 8 26.0 ft 10.0 ft heat/cool 14.0 x 12.0 ft 168.0 ft2 BATH 4 5.0 ft 10.0 ft heat/cool 1.0 x 105.0 ft 105.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area . (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-0ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2_glazing,clr low-e___. 13A-4ocs------ --- 13A-3ocs 2 glazing, clr low-e 2 glazing, clr'low-e 2 glazing, clr low-e 2 glazing, clr low-e 2.glazing, clr-low-e___._ 13A-flocs -- - -- - - - _ 13A-flocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e .2 glazing, clr low-e-- _ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 11 GO _ .16B-30ad--- . , 22A_tph_.-- - 0.143 0.650 0.650 0.650 -- --- 0.650 -0.143 0.143 0.650 0.650 0.650 0.650 0.650 0.143 - _.._- - .-..--'0. 0.143 0.650 0.650 0.650 -----_ 0.650 0.143 0.650 0.650 0.650 0.540 __0.032 _--1,358 ne ne ne ne .. ne e se se se se se _se._ s "-sw .. sw sw sw .-sw_ nw nw nw, nw nw _ - _ _.__ 4.00 18.20 0.00 0.00, __-18.20 ---.--0.00. 4.00 18.20 0.00 0:00 0.00 __. _ .0.00. 0.00 4.00 0.00 18.20 0.00 --,.-0.00 4.00 18.20 0.00 18.20 0.00 __0.9Q _.__38 02 2.19 26.88 0.00 0.00 ----26.88 --.--0.00 2.19 27.05 0.00 0.00 0.00 __T0.00 0.00 _-._-- -' 2.19 0.00 27.05 0.00 -- -0.00 2.19 26.88 0.00 26.88 0.00 0 0 0 0 _ ___0 - - --- 0 0 0 0 0 0 v -___- _0 0 -- d 120 0 0 0 -._- ____p 140 12 0 0 - - - -0 168 ------168 0 0 0 0 __0 . -- ___0 0 0 0 0 0 _-__... _0 0 - - --- --- 120 0 0 0 - -_- Q 128 0 0 0 -- - 0 _ 168 --- -26 0 0 0 0 -- --._ 0 - ----0 0 0 0 0 0 ------ 0 0 - ---- - 480 0 0 0 -- _--0 513 218 0 0 - 0 - __ 151. - -989 0 0 0 0 -_..- '_ _._ 0 - ----0 0 6 0 0 0 - ------ 0 _. -_ 0 263 0 0 0 _-----0 280 323 0 0 - - 0 -_--_269 _-- 0 0 0 0 0 __- ._-0 ----0 0 0 0 0 0 -,---- _ -- 0 - 0 50 0 0 0 -- _ -9 0 0 0 0 ---- 0 _-. 10.5 ---10.5.. 0 0 0 0 --- -_._-0 - 0 0 0 0 0 0 ---_ - --0 --- 0 50 0 0 0 _ -- -0 0 0 0 0 - --0 -_ 105 0 0 0 0 ---- ---_ 0 ------0 0 0 0 0 0 _.-_____-0 0 -- -:2-0-0 0 0 0 -- 0 0 0 0 - --0 _ -_-94. 0 0 0 0 _- ._-0. . -- 0 0 0 0 0 - --_- -0 0 -- - - - 109 0 0 0 0 0 0 0 0 - - - 0 _ _ 168 _ W---. W --- C __ F_._ _.._ - -_1.60 _.--0,00 6 c)AED excursion -12 -60 Envelope loss/gain 2351 1122 484 218 12 a) Infiltration b) Room ventilation 351 0 101 0 67 0 19 0 13 Internal gains: Occupants @ 230 Appliances/other 2 460 500 0 0 900 Subtotal (lines 6 to 13) 2701 2183 552 1137 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 1 20% 34% 0 0 0 2701 544 0 0 0 2183 746 20% 34% 0 0 0 552 111 0 0 0 1137 389 Total room load Air required (cfm) I I 3245 13OF 2929 126 1 127 663 1526 66 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,A -rk wrightsaft' 2017-Oct-25 09:28:24 RightSuite® Universal 2017 17.0.08 RSU08101 �� Page 21 E:\Documnets\Wdghtsoft WAC\ALMORE RES[DENCE.rup Calc = MJ8 Front Door faces: SE -�- wrightsoft° Right-M Worksheet Job: ` UNIT 3 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M WIC 1 U3 UTILITY ROOM 2 Exposed wall 6.0 ft 10.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 f? 12.0 x 4.0 ft. 48.0 ft2 Ty \ Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftZ°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs-ne-- 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 - ne ne v�4.0-0 18.20, 0.00 m 2.19 2688 0.00 _ 0 0 0 . _,_ _0 0 0 0 0 0 ---0_-- 0 0 0 0 0 --0 0 0 --------0 0 0 0 0 0 11 2 glazing, clrlow-e 2.glazing_clr_tow-e_._.: 0.650 ,-_._ 0.650 ne _ane_.__ 0.00 18.20 0.00 __..__26,88 0 r.._ _0.-_.--Q-._..__,.-r0._ 0 0 0 ^0 0 - - _._0'__0 0 0 _...._.__0.-__..__-0 0 _ 13A49cs _.-.-.:..._, 13A-4ocs 2 glazing; clrlow-e 0.143 0.143 0.650 _ e .. se se ----Q-0-Q 4.00 18.20 _ .0_00 2:1g 27.05 - _0 0 0 . _:. 0------ A 0. 0' 0 Q 0 0 _ _. _9 60 0 _._ 0 60 0 - --0 - 246 0 ___ 0 131 0 2 glazing, clr low-e 2 glazing, clr low-e _ 0.650 0.650 "se se 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _ W -- 2, glazing, clrlow-e 2 glazing,_clr:low ems._ _ 13A-4ocs 13A�ocs _ - 0.650 : ..___0.650 0.143 0.143 se ,.,se_ s sw 0.00 O.00. 0.00 4.00 0.00, _._.__O.00 0.00 2.19 0 _.__ ._ _:_0 0 __.66 0 .,._w_._a. 0 0 -. -66 0 - ;M 0 0 - 240 0 _- _ __0. 0 _ 131 0 ______e__,_0 0 40 0 ---- __ --- 0 0 _- 2-6 0 0 - 0. 0___.- 43 0 - 78 2 glazing; cir lower 0.650 sw 0.00! 0.00 0 0 0 .0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e Z.glazing,-cIr.Iow!g _ 0.650 0.650 .�_- _0.650 sw sw _swr 18.20 0.00 _,--_0.00 27.05 .- 0:00 . .0;00 0 0 �_ 0 0 0 _-_ _.-,�-Q 0 0 _...-..._..-0 - 0 0 __0 20 0 _0 0 0 _ �..�0 371 0 _0 552 0 ___ Q 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11 GO 0.650 0.540 nw nw_ 18.20 0.00 26.8E 0.00 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 C _._.:1613-30ad-. ----032 _ ._' 0:90 -=� .60 _ -.� ..__-30 _ _ 30 _ .�__ 27 '. _ 48 _ _0 -y_ 48 _ .-�_ -48 43 ____ __ --7-7 22A-tph_ 1.358` . _ _ 38.02 0.00 - . 30 _ 6 228 4$ _. -_ x 6 c)AED excursion -10 126 Envelope loss/gain 495 169 1113 928 12 a) Infiltration 81 23 135 39 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 576 192 1248 967 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 190 61 14 Subtotal 576 192 1438 1028 15 Duct loads 1 20% 34% 116 66 20% 34% 2901 351 Total room load 1 692 258 1728 1380 Air required (cfm) 128 11 1 69 59 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ArlA- wright50ft' Right -Suite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 Page 22 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE g * wrightsoft Right-J® Worksheet Job: ` UNIT 3 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS a,\OL.COM 1 Room name HALL U3 NOOK U3 2 Exposed wall 8.0 ft 17.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft - heat/cool 4 5 Room dimensions Room area 8.0 x 4.0 ft 32.0 ft' 10.0 x 12.0 ft 120.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 13A-4ocs-- -- 2 glazing, cir low-e 2glazing, clrlow-e ---0.143 0.650 0.650 ne ne ne --- 4.00 18.20 0.00 --2.19-- 26.88 0.00 0 0 0 ----0 0 0 -- -0 0 0 ----0 0 0 --- 70 0 0 - -- 50 0 0 -- 199 0 0 - - 109 0 0 11 __- , 2 glazing, cir low-e 2.glazing, clr low e__ 0.650 . --___ 0.650 ne __ne__ 0.00 ___18.20- 0.00 _-26.88 0 __-__ _0 0 _-_0 0 ______0 .6 -_ 0 0 _ __-_20 0 ___j0 0 --_.371- 0 -, 548 W -- - 13A-flocs 13A-4ocs - - 2 glazing, -cir low-e 0.143 ----0.143 0.650 a se se 0.00 - 4.00 18.20 _ __ 0.00 2.19 27.05 0 . - - 80 0 0 ----a0 0 0 - - -320 0 0 - --175 0 0 --- -0 0 0 - -- 0 0 0 --- 0 0 0 - - - 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, cir low-e 2.glazing,, clr low=e_ - 13A-4ocs 0.650 ---0.650 0.143 se - se s 0.00 O.OQ 0.00 0.00 _ -. 0.00 0.00 0 - - 0 0 0 -- - 0 0 - - - 0 0 0 - - -0 0 0 - - 0 0 0 -- - --0 0 0 - - - -0. 0 0 - 0. 0 glazing, clr low-e _7-.-- 0.650 sw sw - - 4.00 0.00 - - " - 2.19 0.00 --- - 0 - 0 - - -'"T ' 0 0 - -- � 0 0 ____-- 0 0 _ 0 0 --0.143 -~-02 0 0 _.____.. v0 0 t2glazin 2 glazing, clr low-e 2 glazing, cir low-e g, clr low a 0.650 0.650 _- -0.650 sw sw sw 18.20 0.00 ---- 0.0-Q 27.05 0.00 -- -0:00 0 0 __..._-- 0 0 0 - -- -0 0 0 -- --0 0 0 ---------0 0 0 ------0 0 0 _ - - 0 0 0 -- -- 0 0 0 -- -� 13A4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 100 12 0 88 0 0 352 218 0 193 323 0 2 glazing, cir low-e 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 -- - .11G0 - -- -- - - - - - - -- -- .-0 - - - - - - -0 - --0 __--192 F _---• 22A_tPh___-__-- .- ---_1,358 __�. _.-38.02- ___-0.00 ._ _ _.._$2 ____._...__ 8 -.__._ 304 .. �-_._. _ 0 .._.,.___ 120 -- _--�� -- _648 ._._ __ -0 6 c)AED excursion -13 -96 Envelope loss/gain 653 213 1895 1268 12 a) Infiltration 108 31 229 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13) 761 244 2124 1834 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -761 -244 0 0 14 Subtotal 0 0 2124 1834 15 Duct loads 20% 34% 0 0 20% 34% 428 627 Total room load 0 0 2551 2460 Air required (cfm) 0 _2L 102 106 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACC,k-Fk W right90ft' Right -Suite@ Universal 2017 17.0.08 RSU08101 2017-Oct-25 Pa09:ge 23 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 9 wrightsoft° Right-J® Worksheet Job: ` UNIT 3 Date: OCT. 25, 2017 QUICK CALCS, INC. By. - 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name FOYER U3 FAMILY ROOM U3 2 Eposed wall 5.0 ft 14.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 ftz 1.0 x 339.0 ft 339.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13Aflocs_.___-._._._ 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 ne ne ne ,- 4.00 18.20 0:00 2:19' 26.88 0.00 0........--..-0_.__-. 0 0 0 0 -_ 0_O______.O 0 0 0 0 0 0 ---. ------ 0--_ 0 0 --___O 0 0 ___-___- 0 0 0 11 2 glazing, clr low-e 2_glazing,.clr_low a--- 0.650 --- -- 0.650 ne --ne.. 0.00 ------18.20 0.00 26.8.8 , 0 . ---- _-_ .0 0 y.. _.- _._ :0 0 _ .__ __0 0 - .__ - -A 0 _ -- -0 0 - - _ __0 0 0 ---- -_ _0. W __ 13-A-4ocs----- - - 13A-4ocs 2 glazing, clr.low-e -- --0,143 0.143 0.650 -- e-- se se --- 0.00 4.00 18.20 ----OAO 2.19 27.05 __ _ __ _ 0 ' 50 20 _ _ _ _ 0 30 0 - - 119 371 -- -- 0 65 552 -- - -0 0 0 -- 0___ 0 0 -- 0 0 0 - ___0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, clr low-e .2 glazing, clr low e___ 13AAocs 0.650 _ _ _ 0.650 0.143 se --se- s 0.00 .:_ _ 0.00 0.00 0.00 :--- 0:00 0.00 0 _ _-_---0 0 0 --- -- -0 0 0 --_---_ A 0 0 --_ ---- 0 0 0 ---- - -- -0 0 0 --- --0 0 0 ---- -_-0.._ 0 0 - -----0 0 --- -�-. -- 13A-4ocs 2 glazing, clr low-e - __ 0..143 0.650 - sw sw -- 4.00' 0.00 - - 2.19 0.00 �'-- -- 0 0 - -- 0 ---- 0 0 ._ __- 0 0 _._ ._ -. 0 - --_-- -0 0 - 0 0 - -- 0 0 2 glazing, clr low-e 2 glazing, clr low-e 2-glazing, clr low-e---- 0.650 0.650 -- --0 650 sw sw sw 18.20 0.00 ---- 0.00 27.05 0.00 _0:00 0 0- _0 0 0 ._ _ --- _O 0 0 - __ .___0 0 0 ----- - 0 0 0 -------- 0 0 0 ----__9 0 0 _ _-- ----0 0 0 .-__-_-0_ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 _ 0.00 0 0 0 0 0 0 0 0 0 0 0 0 140 0 0 92 0 0 368 0 0 201 0 0 2 glazing, clr low-e 11G0 0.650 0_540 nw nw 18.20 26.88 0.00 0 0 0 0-- 0 0 0 0 48 0 0 874 0 1290 C_-_-• _ -._ 16B 30ad .------- �- _----_0.032 ___. - -0.00 __,0.90- -- ----1,60 -- -- ___ -30. - - -_---. -.30 --.---27- - -- 48 - `-339 --0 _ ---- 339 --- ---- _304. - - -0 --- -542 _7_ _ 38._02 - 0.00. ,_ _-_ 3-0 - __-- 6 c)AED excursion -14 258 Envelope loss/gain 707 651 2078 2292 12 a) Infiltration 67 19 189 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal (lines 6 to 13) 774 670 2267 3246 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -774 -670 485 281 14 Subtotal 0 0 2752 3527 15 Duct loads 20% 34%1 0 0 20°/0 34% 554 1205 Total room load 0 0 3307 4732 Air required (cfm) 0 0 132 203 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. ACZK wrightsOft' Right -Suite@ Universal 2017 17.0.08 RSU08101 2017-Oct-25 g Page 24 E:\Dccumnets\Wrightsoft HWAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE y. -�- wrightsoft® Right-JO Worksheet Job: UNIT 3 Date: OCT. 25, 2017 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 10 CLST 10 2 Exposed wall 11.0 ft 13.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 11.0 x 11.0 ft 121.0 ft2 2.0 x 11.0 ft 22.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft') Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 2 glazing, cir low-e: 2 glazing, cir low-e 0.143 0.650 0.650 --ne"- ne he 4.00 18.210 0.00 ~ - 2.19 26.88 0.00 �v 0 0 0 ^^0 0 0 0 0 �m -0 0 0 110 0 0 yv 110 0 0, 4� 440 0 0 v 241 0 0 2 glazing, cir low-e 2_glazing,..clrtow a _. 0.650 _ 0.650 ne . ,ne_ 0.00' _ 8.20;0- _,.1 0.00 .0 0 0 0 0 6 0 0 3Y. _ _ 13A-4acs -. 13A4ocs 2 glazing, cir low-e 0.143 0.143 '0.650 _ e . se se _.__ 0.00_ Zoo 18.20 0,00 2:19 27.05 _ 0 -V 110 . 15 0 M 95 0 -0 '"380 273 0 208 406 __._. 0 20 ` 0 _. _0 ' A 20 0 _. _- _-_- 0 80 0 - -- 44 0 2 glazing, clr low-e 2 glazing, clriow-e 0.650 0.650 se se 0.00 0.00 000 Oi00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, clr low-e 2,glaiing,,clrIgw- ,___ 13A4ocs 13Aflocs 2 glazing, cir low-e 0.650 �_,_0.:650 0.143 _._-___.. 0.143 0.650 se -se_. s sw: sw 000 _ ,_._ 0.00 0.00 _.___ 4.00 0.00 0.00 _-, -0.00 0.00 2;19 0.00 0 -0 0 - 0 0 0 _------0 0 _0-- 0 0 e__. ____A 0 0 0 0 __ 0 0 _0__�.. 0 0 _ _0 0 _0O 0 0 -----_0 0 0 0 ____0 0, _ 0 0 0 0 _=O0 0 2 glazing, cir low-e 2 glazing, clr low-e 2,glazi.9 clr low-e_- 0.650 0.650 _.�_,_ 0,650 sw sw --s-w- '18.20 0.00 __._.�090_ 27.05 0.00 0:00 0 0 : __ 0. 0 0 _-_m0 0 0 . _ _0 0: 0 ____.� 0 0 0 ._-_ 0 0 0 __ 0 0 0 0 0 _0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11GO 161330ad_ _ 0.650 0.540 _--.0.032:._�_ nw nw 18.20 0.00 0.90.. 26.88 0.00 1;60 0 0 _ .__v121 0 0 0 0 0 0 0 0 0 0 0 0 0 0 22A-tph 1.358 _ -_ 38.02, �0.00 12.1 ____ -- 418 0 -_ -y 22 q 13 _ 494 __ 0 6 c)AED excursion -64 -18 Envelope loss/gain 1180 7441 1035 301 12 a) Infiltration 148 43 175 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13) 1328 1516 1210 352 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 1297 -1210 -352 14 Subtotal 2626 2 E01 0 0 15 Duct loads 20% 34% 529 20% 34% 0 0 Total room load --T 3154 2751 -T-0 0 Air required (cfm) 126 118 0 0 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. wrightsoft' 2017-Oct-25 09:28:24 ACC*,.RightSuite® Universal 2017 17.0.08 RSU08101 Page 25 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE -�- wrightsoft° Right-J® Worksheet Job: UNIT 3 Date: OCT. 25, 2017 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 5 CLST 9 2 Bposed wall 5.0 ft 2.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 9.0 x 2.0 ft 18.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft�-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6...____..--13A4cs 2 glazing, clrlow-e 2 glazing, clr low-e 0.143 0.650 0.650 ne_ ne ne - 4W 18.20 0.00 2.19-50_.__.__.- 26.88 0.00 6 0 0 0 _.__.._176 109 0 96._. 161 0 •__-20- 0 0 20 D 0 -- 80-44 0 0 0 0 11 2 glazing, clr low-e _2.glazing,-clrlow-a-._-- 0.650 --,--0.650 ne -ne- 0.00 _-18.20- 0.00 26.88 0 _-----.._.0 0 -_--_-- 0 0 -- ----0 0 _-_----.__0 0 0 0 _0 0 ----0 0 -_- -0- . W - - - 13A-4ocs 13A flocs ..._ -- 2 glazing, clr low-e 0,143 ---- 0.143 0.650 e__ se se 0.00 - 4.00 18.20 0.00 - -2.19 27.05 - - - 0 0 0 - --b 0 0 --6 0 0 - -6 0 0 - - 0 0 0 -- -0 0 0 - 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.650 0.650 se se 0.00 0.00' 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ._ r ..2-glazing, 2.glazing, clr low-e clraow-e---_ 13A.4ocs 13A4ocs 2 glazing, clr low-e 0.650 --0.650 _0.650 0.143 0.143 0.650 se - se-- s sw sw 0.00 _-_ .0.00- 0.00 4.00 0.00 0.00 --- _0.00 0.00 -_. 2.19 0.00 0 __------0 -0 . _ 0 0 0 -_ _---_ 0 0 _- --- -_0 0 0 -0 0 ----- ---0 0 0 ___0 0 -- -- 0 0 0 .-. _-.----0 0 _------ -0 0 0 ---- - -0 0 - - -- - -0 0 0 --- - ___0- 0 _ - ---- 0 0 0 ---- _---0_ 0 ----- `0 0 2 glazing, clr low-e 2 glazing, clr iow-e 2,glazing, clr bw:e _ 0.650 0.650 _ 0,650 sw sw sw - 18.20 0.00 --__0.00 27.05 0:00 0,00 0 0 _ 0 0 0 .._--------_0 0 0 ---._-_-0 0 0 -- 0 0 .0 ---------0 0 0 -_.---_0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 11G0 0.650 0.540 nw nw 18.20 0.00 26.88 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 166-30ad _ - _- --- -_----0.032 -- ; --- 0.90. _ -- 1.60'-_- - --- -- 40. ___.-_72 ----- 18 ------ - 18 .- -- - 16....___ -_.-29 _ 45 _..-----_45 _-.1.358 _ c_ _ ... 38.02 -- 0.00 ---45 - --- 5 -.. -.190 --- ..__..-_ .18 ..- - 2 ---- 76 _ _-_-Q 6 c)AED excursion -17 -4 Envelope loss/gain 516 312 172 69 12 a) Infiltration 67 19 27 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 583 332 199 76 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 276 88 -199 -76 14 Subtotal 859 420 0 0 15 Duct loads 20% 34% 173 144 20% 34% 0 0 Total room load 1032 563 0 0 Air required (cfm) 141 24 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wright30ft' Ri htSuite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 09:28:24 ACCA 9 Page 26 E:\Documnets\Wrightsoft HVAC\ALMORE RES[DENCE.rup Calc = MJ8 Front Door faces: SE -�d- wrightsofe Right-J® Worksheet Job: UNIT 3 Date: OCT. 25, 2017 QUICK CALCS, INCay:. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M WIC 2 U3 DINING ROOM U3 2 Exposed wall 0 ft 24.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 ft2 12.0 x 11.0 ft 132.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft-) Load number (Btuh/ft;°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 _ 13W-4ocs ______..._. 2 glazing, clr low-e 2 glazing, clr low-e _._, - 0:143 '0.650 0.650 ne ne ne _w 4.00 18.20 0.00 26.88 0.00 __- _a ,0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 i___0.650 he -ne_ 0.00 18.20 0.00 ®26.88 0 0 0 __ _ _ 0 0 �. 0 0 0 _0 0 _ `_0 0 _ 0 0 A �0 �0 0 W -- 13A-4acs_` 13A-4ocs 2 glazing, clrlow-e 0.143 ^'^0.143 0.650 a se se 0.00 4.00 18.20 _ 2.19 27.05 " 0 0 0 0 0 0 - _ 120 30 90 0 - 360 546 - 197 811 2 glazing, clr low-e 2 glazing, cirlow-e 0.650 0.650 se se 0.00 0.00; 0.60 0.00 0 0 0 0 0 0 '0 0 0 .0 0 0 0 0 0 0 _ 2 glazing, cir low- 2_glazing, clr_low�-__ 0.650 ____-0.650 se _se_ 0.00 --,___0.00 0.00 __.__0;00. 0 _ _ w 0 0 __ 0 0 -___ 0 . 0 _----__0 0 __, ._-._0 0 ._.__..- _0 0 _-- __0_ 0 __ 0. _ 13A ocs 2 glazing, clr low-e - ---- = 0.143 0.650 sw sw � __ .166 0.00 6 2,19 -0.00 0_ '__"_ _ O 0 0 ..__ 0 0 _ 0 01 0 w _6 0 0 _._ __,f0 0 0 70 0 0 _ 280 0 0 , . 153 0 2,glazing, clr low-e 2 glazing, clr low-e Z,glazing, clr low e . 0.650 0.650 _ 0 650 sw sw __sw 18.20 ' 0.00 M0,00 27.05 0.00 _L_Q.00 0 0 0 0 0 _ . 0 0 0 _ 0 0 0 0 0 0 0 0 q .0 0 ____- Q 0 0 _ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.650 0.650 nw nw nw 4.00 18.20 0.00 2.19 26.88 0.00 _ 0 0 0 0 0 0 ___._,0 0 0 0 _ _ 0 0 0 . - 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11GO 0.650 0.540 nw nw 18.20 0.00 26.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 032 _0.00 1.60 ___ _,. 30 ._ _ ___30 „ _,___2 , __ 48 _ _ 132 ._.. _._ 132 . _ � _ 118 _211, 1.358 _ -__ _.._38.02 �-_- ffl 30 0 .0.__ 0 .__.___132 ________24 ------- 913 _-___.__ 0 6 c)AED excursion -2 -98 Envelope loss/gain 27 461 2418 1384 12 a) Infiltration 0 0 324 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 27 46 2742 2477 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 143 170 0 46 91 0 464 3205 0 298 2775 15 Duct loads 20% 34% 34 31 20% 34% 645 948 Total room load T Air required (cfm) I204 8 123 5 1 1 3850 154 3723 160 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. MCP. wrightsoft' RightSuite® Universal 2017 17.0.08 RSU08101 2017-Oct-25 P09:ag e 27 E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Cale = MJ8 Front Door faces: SE f Duct System Summary Job: •J -- wrightsoft• Date: OCT. 25, 2017 UNIT 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM For: ALMORE RESIDENCE, TC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm 229 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 1 h 1116 54 22 1.000 5.0 Ox 0 VIFx 37.4 135.0 st12 BEDROOM 2 c 2842 102 123 1.000 7.0 Ox0 VIFx 18.2 115.0 st5 BEDROOM 3 c 2954 110 128 1.000 7.0 Ox0 VIFx 40.4 135.0 st12 BEDROOM 4 c 2847 97 123 1.000 7.0 Ox0 VIFx 13.7 115.0 st5 DINING ROOM c 3588 124 155 1.000 8.0 Ox0 VIFx 27.2 115.0 Sty FAMILY ROOM h 2474 119 83 1.000 6.0 Ox0 VIFx 40.7 135.0 st12 FOYER -A c 2651 105 115 1.000 7.0 Ox0 VIFx 47.1 140.0 st13 KITCHEN c 3498 14 152 1.000 8.0 Ox 0 VIFx 41.0 135.0 st12 LAUNDRY h 1209 58 53 1.000 6.0 Ox0 VIFx 17.8 115.0 st5 LIVING ROOM c 2249 71 97 1.000 7.0 Ox0 VIFx 68.3 160.0 st14 LIVING ROOM -A c 2249 71 97 1.000 7.0 Ox0 VIFx 68.3 160.0 st14 M WIC 1 h 924 44 15 1.000 4.0 Ox0 VIFx 49.3 140.0 st13 M WIC 2 c 83 2 4 1.000 4.0 Ox 0 VIFx 44.8 140.0 st13 MASTER BATH h 5403 260 117 1.000 7.0 Ox 0 VIFx 44.8 140.0 st13 MASTER BEDROOM h 3284 158 133 1.000 7.0 Ox0 VIFx 68.6 160.0 st14 MASTER BEDROOM -A h 3284 158 133 1.000 7.0 Ox 0 VIFx 66.1 160.0 st14 wri htsoft' 2017-Oct-25 09:28:30 A � 9 RightSuite® Universal 2017 17.0.08 RSU08101 Page 1 ZA E:\Documnels\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st14 Peak AVF 459 460 1.000 697 11.0 0 x 0 VinlFlx st13 st13 Peak AVF 871 711 1.000 1109 12.0 0 x 0 VinlFlx st6 st6 Peak AVF 871 711 1.000 1109 12.0 0 x 0 VinlFlx st12 Peak AVF 297 384 1.000 705 10.0 0 x 0 VinlFlx st5 st5 Peak AVF 679 839 1.000 785 14.0 0 x 0 VinlFlx Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk W Ox 0 1550 1550 0 0 0 0 Ox 0 VIFx C wri htsoftt 2017-Oct-25 09:28:30 i� 9 Right -Suite® Universal 2017 17.0.08 RSU08101 AM E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 2 • - wrightsoft. Duct System Summary UNIT 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS a,10L.COM For. ALMORE RESIDENCE, TC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 967 cfm Job: Date: OCT. 25, 2017 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500/0 '.500 in H2O 1.000 in/100ft 967 cfm 167 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 c 661 11 29 1.000 5.0 Ox 0 VIFx 12.9 115.0 st3 BATH 3 h 1017 35 25 1.000 5.0 Ox 0 VIFx 24.1 135.0 st11 BATH 6 h 2242 78 57 1.000 6.0 Ox 0 VIFx 25.7 135.0 st10 BEDROOM 5 h 3398 118 104 1.000 7.0 Ox0 VIFx 12.9 115.0 st3 BEDROOM 6 h 3107 108 101 1.000 7.0 Ox0 VIFx 26.5 135.0 st11 BEDROOM 7 h 3698 129 96 1.000 7.0 Ox0 VIFx 31.9 135.0 st11 DINING ROOM U2 h 3970 138 117 1.000 7.0 Ox0 VIFx 14.5 115.0 st4 ENTRY U2 h 3049 106 72 1.000 6.0 Ox 0 VIFx 22.3 135.0 st10 FAMILY ROOM U2 c 2365 56 104 1.000 7.0 Ox 0 VIFx 25.6 135.0 st11 FAMILY ROOM U2-A C 2365 56 104 1.000 7.0 Ox0 VIFx 9.6 115.0 st4 LAUNDRY U2 c 1067 41 47 1.000 6.0 Ox0 VIFx 25.7 135.0 st10 M WIC 1 U2 c 61 1 3 1.000 4.0 Ox 0 VIFx 21.6 135.0 st10 M WIC 2 U2 c 61 1 3 1.000 4.0 Ox0 VIFx 10.3 115.0 st3 NOOK U2 C 2404 88 106 1.000 7.0 Ox 0 VIFx 13.1 115.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 522 547 1.000 697 12.0 0 x 0 VinlFlx st11 Peak AVF 328 326 1.000 742 9.0 0 x 0 VinlFlx st4 st3 Peak AVF 445 420 1.000 816 10.0 0 x 0 VinlFlx st10 Peak AVF 227 178 1.000 649 8.0 0 x 0 VinlFlx st3 ,�`i. + wrightSOft° RightSuite® Universal 2017 17.0.08 RSU08101 Z& E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 2017-Oct-25 09:28:30 Page 3 +, Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb4 Ox 0 967 967 0 0 0 0 Ox 0 VIFx wrightsoft® Right -Suite® Universal 2017 17.0.08 RSU08101 AMA E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE 2017-Oct-25 09:28:30 Page 4 r 9 Duct System Summary Job: wrl htsoft y Date: OCT. 25, 2017 UNIT 3 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: ALMORE RESIDENCE, TIC CUSTOM HOMES 20025 SOUTHERN STAR DRIVE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 967 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 967 cfm 169 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 4 c 1526 27 66 1.000 6.0 Ox 0 VIFx 14.2 115.0 st2 BATH 5 h 1032 41 24 1.000 5.0 Ox 0 VIFx 26.1 135.0 st8 BEDROOM 10 h 3154 126 118 1.000 7.0 Ox0 VIFx 33.8 135.0 st8 BEDROOM 8 h 3245 130 126 1.000 7.0 Ox0 VIFx 20.9 135.0 st9 BEDROOM 9 h 3754 150 89 1.000 7.0 Ox0 VIFx 32.8 135.0 st8 DINING ROOM U3 c 3723 154 160 1.000 8.0 Ox 0 VIFx 16.9 115.0 st1 FAMILY ROOM U3 c 2366 66 102 1.000 7.0 Ox 0 VIFx 11.8 115.0 st1 FAMILY ROOM U3-A c 2366 66 102 1.000 7.0 Ox 0 VIFx 28.0 135.0 st8 M WIC 1 U3 h 692 28 11 1.000 4.0 Ox0 VIFx 13.6 115.0 st2 M WIC 2 U3 h 204 8 5 1.000 4.0 Ox 0 VIFx 10.2 115.0 st2 NOOK U3 c 2460 102 106 1.000 7.0 Ox 0 VIFx 21.3 135.0 st9 UTILITY ROOM h 1728 69 59 1.000 6.0 Ox0 VIFx 13.1 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 604 594 1.000 769 12.0 0 x 0 VinlFlx st8 Peak AVF 384 333 1.000 868 9.0 0 x 0 VinlFlx st1 st9 Peak AVF 232 232 1.000 664 8.0 0 x 0 VinlFlx st2 st2 Peak AVF 363 373 1.000 683 10.0 0 x 0 VinlFlx A wri htft° 2017-Oct-25 09:28:30 ^. 9soRightSuite® Universal 2017 17.0.08 RSU08101 AE& E:\Documnets\Wrightsoft HVAC\ALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 5 Return Branch Detail Table Name Grill Size (in) Htg (cfm) CIg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb5 Ox0 967 967 0 0 0 0 Ox 0 VIFx C wri htSOft° 2017-Oct-25 09:28:30 ^_ 9 Right -Suite® Universal 2017 17.0.08 RSU08101 EADocumnetsMightsoft WAMALMORE RESIDENCE.rup Calc = MJ8 Front Door faces: SE Page 6