Loading...
HomeMy WebLinkAboutReview CommentsI Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 20025 Southern Star Dr City / State / Zip: Fort Pierce, FI 34945 Parcel#: 2215-700-0009-000/8 Zoning: REVIEW COMMENTS IVE® Page 1 Nov 15 2017 Owner(s): Bertrand Laidler Jr / Charlotte Almore / Michael E Bell li Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 Block: APPLICATION INFORMATION Permit Number: 1709-0086 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Michael J Miranda Business Name: Group One Construction & Dev Inc Business Addr: 10302 S Federal Hwy Ste 164 City / State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS' Review Tyoe Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith Comment: DOCUMENTS MISSING 9/20/2017 Comment: 9/22/2017 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) 10/2/2017 Comment: Comment: 10/2/2017 Comment: 10/212017 Automatic Sprinkler System? No Fax Number: 772-334-0804 Date Started 9/22/2017 PENDING Lashahna Ingram VEG PERMIT IN DRAWER UNDER "A" ALMORE. NO FEE SUB AGREEMENTS FOR MECHANICAL AND ROOF. COMPLETE Lynn Swartzel 9/18/2017 COMPLETE Lashahna Ingram 9/6/2017 INCOMPLETE William Durden 11/8/2017 Email: Mikemiranda3074@Aol.Co m Date Completed 9125/2017 9/18/2017 9/6/2017 Date Released 9/25/2017 911812017 9/6/2017 - PLEASE CLARIFY THE DESCRIPTION OF MULTIPLE HOUSES SPECIFIED IN THE ENERGY CALC'S. STRUCTURE IS A SINGLE-FAMILY RESIDENCE. • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES OF WINDOWS ON PLANS. PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION 5TH EDITION. SUBMITTED WALL DETAIL SHOWS R-13 WALL INSULATION, ENERGY CALC'S DO NOT SHOW THE INSULATION OF THE SEPARATION WALL. PLEASE CORRECT. 6. SHOW INTERIOR WALL DETAIL FOR THE SEPARATION OF THE GARAGE TO HOUSE INCLUDING INSULATION AND R VALUE. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS e2 Comment: PAGE 3 OF 5, WINDOWS SHGC AND THE U-FACTOR ARE THE SAME FOR ALL FENESTRATION AND THE NFRC IS MARKED YES. PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FROM THE MANUFACTURE. PAGE 3 OF 5 WILL NEED TO BE CORRECTED. 10/2/2017 * PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. 10/2/2017 Comment: ENERGY CALC'S ONLY CALL OUT ONE WATER HEATER, PLANS SHOW 3. PLEASE CLARIFY. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment: THE PRODUCT APPROVALS THAT WERE SUBMITTED IS FOR THE METAL ROOF, PLEASE SUBMIT THE ROOF UNDERLAYMENT. 10/2/2017 10/2/2017 Comment: PLANS EXAMINER ELECTRIC 10/4/2017 Comment: 10/4/2017 Comment: PLANS EXAMINER MECHANICAL PLEASE SUBMIT THE ROOF UNDERLAYMENT PRODUCT APPROVALS IN DUPLICATE. MEETING THE REQUIREMENTS OF CHAPTER 9 SECTION R905.10.5 SUBSECTION R105.10.5.2 OF THE 2014 FLORIDA BUIDING CODE. * THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2010 FLORIDA BUILDING CODE INCOMPLETE Joe Cicio 10/4/2017 PLS ADD THE QUANTITY OF APPLIANCES ITEMIZED WITHIN THE ELECTRICAL LOAD CALCULATIONS: EX: [ 21 DISHWASHERS [ 31 MECHANICAL SYSTEMS ETC CHECK LOADS FOR APPLIANCES * NOT CONSISTENT WITH THE NEC * APPLIANCES ARE MISSING FROM THE LIST PER THE PLANS INCOMPLETE Joe Cicio 10/3/2017 Comment: HOUSE 1, 2 AND MAIN HOUSE SQUARE FOOTAGES ON SUMMARY SHEETS MUST MATCH THE 10/3/2017 WORKSHEETS 10/3/2017 Comment: SHOW THE OPENING SIZE AND CFM'S FOR FAMILY ROOM DROP IN HOUSE #1 Comment: SHOW THE LOCATIONS OF ALL MECHANICAL EQUIPMENT ON PLANS * SHOW THE REQUIRED TIE DOWN DETAILS FOR THE EXTERIOR EQUIPMENT PER FBCM 301.15 TO MEET THE DESIGN WIND SPEED AND EXPOSURE *** UNIT #1 AND UNIT #2 WILL NOT FIT IN THE ATTIC LOCATIONS AS SHOWN ON THE MECH 10/3/2017 PLANS * PLEASE CO-ORDINATE THESE LOCATIONS WITH THE TRUSS MANUFACTURERS ENGINEER AND THE ENGINEER OF RECORD * SHOW ALL DETAILS ON PLANS PER FBCR M 1305.1.3 W/ PAN DETAILS AND DRAINS Comment: PLEASE MAKE REFERENCE TO ALL MECHANICAL SYSTEMS ON ALL DOCUMENTS AS SYSTEM 1, SYSTEM 2 10/3/2017 AND SYSTEM 3 * THIS IS A SINGLE FAMILY DWELLING * PLEASE LABEL THESE SYSTEMS ON THE MECHANICAL PLANS Comment: MANUALS AND ENERGY CALCS SPEC R-4 OPEN CORE FOR EXTERIOR WALLS * PLANS SPEC R-9 CORE 10/3/2017 FILLED * PLS CORRECT ONE OR THE OTHER Comment: IF ANY MECHANICAL UNITS ARE IN THE ATTIC TRUSS COMPANY TO SHOW ON LAYOUTS WITH APPROVAL 10/3/2017 OF LOADING * ENERGY CALC IS SPECIFYING ALL [3) UNITS IN ATTIC 10/3/2017 Comment: ENGINEER TO STATE THE CORRECT ADDRESS ON ALL PLANS, ENERGY CALCS AND MANUALS 10/4/2017 Comment: ENERGY CALCS ARE SIGNED INCORRECTLY AND MUST ALL BE ORIGINAL SIGNATURES PLANS EXAMINER PLUMBING INCOMPLETE Joe Cicio 10/4/2017 10/4/2017 Comment: SHOW THE WATER HEATER SIZES ON PLANS AND ADD ADDITIONAL HEATERS TO ENERGY CALCS 10/4/2017 Comment: SHOW THE REQUIRED PAN AND DRAIN SIZES ON PLANS FBCR P 2801.5 10/4/2017 Comment: ENGINEER TO NOTE THE TESTING STANDARDS FOR THE DRAINAGE AND VENT PIPING ON PLANS * SEE FBCR P 3002.1 PLANS EXAMINER REVIEW Comment: ZONING REVIEW 9/22/2017 Comment: 9/22/2017 Comment: COMPLETE William Durden 10/2/2017 111812017 11/8/2017 INCOMPLETE Lydia Galbraith 9/22/2017 PLEASE PROVIDE 2 UPDATED SIGNED AND SEALED SURVEYS WITH PROPOSED CONSTRUCTION, SETBACK, PROPOSED FFE, ELEVATION OF CENTER LINE ROAD, SEPTIC AND WELL. PLEASE PROVIDE 2 FLOOR PLANS AND 2 SURVEYS STAMPED FOR APPROVAL BY HEALTH DEP. ��1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS e3 9/22/2017 Comment: PLEASE PROVIDE HEALTH DEP PERMIT FOR SEPTIC AND WELL Comment: SUBMITTED WARRANTY DEED IS NOT THE LATEST DEED. PROPERTY IS OWNED BY 3 PERSONS THAT 9/22/2017 ARE JOINT TENANTS. Comment: BUILDING PLANS GIVE THE IMPRESSION THE BUILDING TO BE A MULTI FAMILY BLD WITH 3 UNITS. AG 5 ZONING DISTRICT DOESN'T ALLOW MULTI FAMILY. TO BE ABLE TO PROCEED AS SFR THE PLANS SHOULD 9/22/2017 NOT REFER TO MAIN, HOUSE 1 AND HOUSE 2. THE SAME FOR THE MANUAL J'S THEY SHOULD NOT REFER TO MULTIPLE HOUSES. ALL INDICATION TO MULTIPLE UNITS SHOULD BE REMOVED FROM THE PLANS. Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO MISSING INFORMATION. THE PLANS WILL PROCEED THROUGH THE REVIEW PROCESS, HOWEVER, THE PERMIT 9/22/2017 WILL NOT BE ISSUED UNTIL ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE. Planning & Developmerit Services Building & Code Regulation Division, 2300Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6"3 PROPERTY INFORMATION Address: 20025 Southern Star Dr City / State / Zip: Fort Pierce, A 34945 Parcel #: 2215-700-0009-000/8 Zoning: REVIEW COMMENTS Page 1 Owner(s): Bertrand Laidler Jr / Charlotte Almore / Michael E Bell li Jurisdiction: SAINT LUCIE COUNTY Lot#: 7 Block: APPLICATION INFORMATION Permit Number: 1709-0086 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Michael J Miranda Business Name: Group One Construction & Dev Inc Business Addr: 10302 S Federal Hwy Ste 164 City / State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS Review Type . Status Reviewed. By ADDRESSING ASSIGNMENT COMPLETE Lydia Galbraith Comment: DOCUMENTS MISSING 9/20/2017 Comment: 9/22/2017 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: Automatic Sprinkler System? No Fax Number: 772-334-0804 Email: Mikemiranda3074@AoI.Co m Date Started Date Completed 9/22/2017 9/25/2017 PENDING Lashahna Ingram VEG PERMIT IN DRAWER UNDER "A" ALMORE. NO FEE SUB AGREEMENTS FOR MECHANICAL AND ROOF. COMPLETE Lynn Swartzel 9/18/2017 9/18/2017 COMPLETE Lashahna Ingram 9/6/2017 9/6/2017 Date Released 912512017 9/18/2017 9/6/2017 PLANS EXAMINER ELECTRIC INCOMPLETE Joe Cicio 10/4/2017 10/412017 Comment: PLS ADD THE QUANTITY OF APPLIANCES ITEMIZED WITHIN THE ELECTRICAL LOAD CALCULATIONS: EX: [ 2 ] DISHWASHERS [ 3 ] MECHANICAL SYSTEMS ETC 10/4/2017 Comment: CHECK LOADS FOR APPLIANCES * NOT CONSISTENT WITH THE NEC * APPLIANCES ARE MISSING FROM THE LIST PER THE PLANS PLANS EXAMINER MECHANICAL INCOMPLETE Joe Cicio 10/312017 10/3/2017 Comment: HOUSE 1, 2 AND MAIN HOUSE SQUARE FOOTAGES ON SUMMARY SHEETS MUST MATCH THE WORKSHEETS 10/3/2017 Comment: SHOW THE OPENING SIZE AND CFM'S FOR FAMILY ROOM DROP IN HOUSE #1 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34992 Phone:(772)462.2172. Fax:(772)462-6443 REVIEW COMMENTS Page 2 Comment: SHOW THE LOCATIONS OF ALL MECHANICAL EQUIPMENT ON PLANS * SHOW THE REQUIRED TIE DOWN DETAILS FOR THE EXTERIOR EQUIPMENT PER FBCM 301.15 TO MEET THE DESIGN WIND SPEED AND EXPOSURE *** UNIT #1 AND UNIT #2 WILL NOT FIT IN THE ATTIC LOCATIONS AS SHOWN ON THE MECH 10/3/2017 PLANS * PLEASE CO-ORDINATE THESE LOCATIONS WITH THE TRUSS MANUFACTURERS ENGINEER AND THE ENGINEER OF RECORD * SHOW ALL DETAILS ON PLANS PER FBCR M 1305.1.3 W/ PAN DETAILS AND DRAINS Comment: PLEASE MAKE REFERENCE TO ALL MECHANICAL SYSTEMS ON ALL DOCUMENTS AS SYSTEM 1, SYSTEM 2 10/3l2017 AND SYSTEM 3 * THIS IS A SINGLE FAMILY DWELLING * PLEASE LABEL THESE SYSTEMS ON THE MECHANICAL PLANS 10/3/2017 Comment: MANUALS AND ENERGY CALCS SPEC R-4 OPEN CORE FOR EXTERIOR WALLS * PLANS SPEC R-9 CORE FILLED * PLS CORRECT ONE OR THE OTHER 10/3/2017 Comment: IF ANY MECHANICAL UNITS ARE IN THE ATTIC TRUSS COMPANY TO SHOW ON LAYOUTS WITH APPROVAL OF LOADING * ENERGY CALC IS SPECIFYING ALL [ 3 ] UNITS IN ATTIC 10/3/2017 Comment: ENGINEER TO STATE THE CORRECT ADDRESS ON ALL PLANS, ENERGY CALCS AND MANUALS 10/4/2017 Comment: ENERGY CALCS ARE SIGNED INCORRECTLY AND MUST ALL BE ORIGINAL SIGNATURES PLANS EXAMINER PLUMBING INCOMPLETE Joe C1cio 10/4/2017 10/4/2017 Comment: 10/4/2017 . Comment: 10/4/2017 Comment: SHOW THE WATER HEATER SIZES ON PLANS AND ADD ADDITIONAL HEATERS TO ENERGY CALCS SHOW THE REQUIRED PAN AND DRAIN SIZES ON PLANS FBCR P 2801.5 ENGINEER TO NOTE THE TESTING STANDARDS FOR THE DRAINAGE AND VENT PIPING ON PLANS * SEE FBCR P 3002.1 PLANS EXAMINER REVIEW INCOMPLETE William Durden 10/2/2017 10/2/2017 Comment: PLEASE CLARIFY SCREENING SECTION ON PAGE A THREE OF FIVE. 10/2/2017 Comment: • PLEASE SHOW ON PLANS SOIL DENSITY SEE SECTION 107 OF THE 2014 FBC. 10/2/2017 Comment: • PLEASE CLARIFY THE DESCRIPTION OF MULTIPLE HOUSES SPECIFIED IN THE ENERGY CALC'S. STRUCTURE IS A SINGLE-FAMILY RESIDENCE. Comment: • LINE SEVEN ON THE ENERGY CALC'S ARE INCORRECT, MULTIPLE TYPES OF WINDOWS ON PLANS. 10/2/2017 PLEASE CORRECT ENERGY CALC'S AS PER SECTION R401.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION 5TH EDITION. 10/2/2017 Comment: 6. SHOW INTERIOR WALL DETAIL FOR THE SEPARATION OF THE GARAGE TO HOUSE INCLUDING INSULATION AND R VALUE. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. 10/2/2017 Comment: 8. FOOTING DETAILS SHOW F -5 FOOTING PLEASE CLARIFY FOOTING DETAIL FOR ALL COLUMNS. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. Comment: PAGE 3 OF 5, WINDOWS SHGC AND THE U-FACTOR.ARE THE SAME FOR ALL FENESTRATION AND THE NFRC IS MARKED YES. PLEASE SUBMIT THE ENERGY PERFORMANCE SHEETS FROM THE MANUFACTURE. PAGE 3 OF 5 WILL NEED TO BE CORRECTED: 10/2/2017 • PLEASE SUBMIT -THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION. Comment: SEE PAGE A-2 SOIL STATEMENT. THE GEOTECHNICAL REPORT WITH RECOMMENDATIONS. 10l2/2017 • PLEASE SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE WITH R401 OF THE 2014 RESIDENTIAL BUILDING CODE. 10/2/2017 Comment: ENERGY CALC'S ONLY CALL OUT ONE WATER HEATER, PLANS SHOW 3. PLEASE CLARIFY. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE. 10/2/2017 Comment: � PLEASE SHOW THE ON THE PLANS THAT THE VENTILATION MEETS THE MINIMUM REQUIREMENTS WITH THE VENTILATION CALCULATIONS. SEE SECTION R806.2 OF THE 2014 RESIDENTIAL BUILDING CODE. Comment: • PLEASE SUBMIT THE ROOF UNDERLAYMENT PRODUCT APPROVALS IN DUPLICATE. MEETING THE 10/2/2017 REQUIREMENTS OF CHAPTER 9 SECTION R905.10.5 SUBSECTION R105.10.5.2 OF THE 2014 FLORIDA BUIDING CODE. 10/2/2017 Comment: • THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2010 FLORIDA BUILDING CODE 10/2/2017 Comment: • PLEASE SHOW THE BEDROOM WINDOWS AS EGRESS PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE Planning &.Development Services Building & Code Regulation Division. 2300 Virginia Avenue FortPierce, FL. 34982 Phone:(772)462-2172 Fax:V72)462-6443 REVIEW COMMENTS Page 3 Comment: -,PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 10/2/2017 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW INCOMPLETE Lydia Galbraith 9/22/2017 9/22/2017 Comment: PLEASE PROVIDE2 UPDATED SIGNED AND SEALED SURVEYS WITH PROPOSED CONSTRUCTION, SETBACK, PROPOSED FFE, ELEVATION OF CENTER LINE ROAD, SEPTIC AND WELL. 9/22/2017 Comment: PLEASE PROVIDE 2 FLOOR PLANS AND 2 SURVEYS STAMPED FOR APPROVAL BY HEALTH DEP. 9/22/2017 Comment: PLEASE PROVIDE HEALTH DEP PERMIT FOR SEPTIC AND WELL 9/22/2017 Comment: SUBMITTED WARRANTY DEED IS NOT THE LATEST DEED. PROPERTY IS OWNED BY 3 PERSONS THAT ARE JOINT TENANTS. Comment: BUILDING PLANS GIVE THE IMPRESSION THE BUILDING TO BE A MULTI FAMILY BLD WITH 3 UNITS. AG 5 9/22/2017 ZONING DISTRICT DOESN'T ALLOW MULTI FAMILY. TO BE ABLE TO PROCEED AS SFR THE PLANS SHOULD NOT REFER TO MAIN, HOUSE 1 AND HOUSE 2..THE SAME FOR THE MANUAL J'S THEY SHOULD NOT REFER TO MULTIPLE HOUSES. ALL INDICATION TO MULTIPLE UNITS SHOULD BE REMOVED FROM THE PLANS. Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO MISSING 9/22/2017 INFORMATION. THE PLANS WILL PROCEED THROUGH THE REVIEW PROCESS, HOWEVER, THE, PERMIT WILL NOT BE ISSUED UNTIL ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE.