HomeMy WebLinkAboutTrussA=LIFE SAFETY WARNING
This symbol identities I e baTety vvarnirigs Mat should
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2.-O: ON CENTER
30' Span'lor less ®
30' to 60' Span
0 degrees
Spreader Bar
Approx 2/3 to
T Line span aPPr�ox.
9
REFER TO BCSI
Truss must be set this Way If crane used.
REFER TO BCSI
Truss must be net this way If crane used.
True. la an example, your trues may not match.
This is an example, truss may not match.
Insist crane operator sets truss this way.
Insist crane operator sets truss this way.
EXCEPT AS NOTED
CEI G AT
1
INDICATES LOAD BEARING
REQUIRED BY TRUSSES 11'
SUPPLIED BY BUILDER
AT A HEIGHT OF 10'-0"
ABOVE FINISHED FLOOR
i
INDICATES LOAD BEARING I
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 12'-0"
ABOVE FINISHED FLOOR
1
0
0
v
M! A ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 21'- 28"IN LENGTH
WITH SPANS LONGER THAN o bee", "' ' ' " ' '-" ' " - " ' - - - - - - + '
3CONSU THE
CONSULT
PIGGY BACK TRUSSES MUST BE ATTACHED AND BRACED PER ENGINEERING DETA
CONSULT BCSI RFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN
METAL ROOFS SHOW IMPE
MULTIPLE PLY TRUSSES MUST
DE FASTENED TOGETHER FER
ENGINEERING DEFORE THEY
ARE SET.
SEAT PLATES BY CHAMBERS
U REPRESENTS A HANGER
Hanger Schedule
T Tap, HT TS26 for 2X4_ ST TH46 for 4X2 excent as shown
Carried
truss
Carrying
truss
Hanger ID
Fasteners for
Carried truss
Fasteners for
Carrying truss
GRG
GRF1
THD26-2
12-10d
18-16d
GRG
GRH
THD26-2
12-10d
18-16d
*Please refer to Standard Engineering package for general instructions on installing hangers.
1 Od=0.148"x 3" 16d=0.162" x 3 1/2"
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
package.
Carrying Girder
tD
ailsmutbe as
hown. Guide tabs oome angle nails.
Truss
L I All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
are installed. AL
AIR h—tA1VDl_i✓1! NET=
UNLESS NOTED ELSEWHERE ON ;THIS LAYOUT. THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENT5. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
CLOUZ ED
AREAS ARE
OF , I'
i�
SPECIAL
CONCERN &
MU
BE
CHECKED
CAREFULLY
& M
Y
t INDICATE
DEVIATION FROM
I
-- ,�
PLANS.�
�.. _
weewee
f.tI
I
�2'-11
3/4„
caeoseH F-
.. ioree.E�a. u
eee or. O
a' oc. Thou
CCAW," Nc14s 24-
a,Ly
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
PIGGY BACK DETAIL
MATERIAL 8, LABOR TO ATTACH PIGGYBACKS
IS THE RESPONSIBILITY OF THE BUILDER.
FAILURE TO ATTACH AS SHOWN CAN RESULT IN FAILURE OF
ROOF, INJURY AND LOSS LIFE. FAILURE CAN OCCUR DURING
INSTALLATION OR LATER.
Badcky 8.48- 1/2' cox PLYWOOD GUSSET ANO
antfty... Let ... I Braalnq
Baas
True" 24" MAX OC
36" MAX OC
BuAeer/Truss Installer la attach posy back trun to bole
trues ellh a'xe'N/2' Plywood aueseet a madman 3e' on
aerter eah 4 ad common had. In bottom ahord of Plgpy
Back Trues and top chord of Bores Truee. au ... I. arc on
both face./dd.. of tr..... Bottom chord of PIM Back
Tines and too chard of B... True" are based a maalmum of
24' an center with 2x4 continuous lateral bracing.
I I I I I 1 I
1 22'-111/4" I 43'-101/8"
43'-41/8" _ 2 3T-31/4"
I
i
I
I
119 TRUSS 6RAWINGS ARE ATTACHED TO LAYOUT
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED Si RETURNED
The legal description of the property where the trusses will be Installed Is:
The undersigned acknowledges and agrees:
1 Trusses will be made In strict accordance with this truss placement diagram layout,
whicttls the sole authority for determining.successful fabrication of the trusses.
2. All dimensions In this layout have been verified by the undersigned.
3. Unless written notice Is provided by cortMed mall to Chambers True$ within tan 10)
days o e e
such written ry a
en nodce le fumlehed Chambers Trues shall have three (3) business days In which
to begin repairs required, or to substitute other trusses, at Chambers option.'
4, The undersigned acknowledges receipt of "SCSI 1-03" summary sheet by TPI 8 WTCA.
6, Delivery Is to job site. It Is the buyere'responslblllty to make the job site suitable for
delivery. Chambers Truss has the sole authority to determine the suitability of the job alto of a
portion of the job she for delivery. Chambers Truss will be responsible for dump delivery only.
The buyer Is responsible for additional delivery expenses IfChambers Truss has to redeliver
because job she is not prepared for delivery or buyer Is not prepared for delivery of trusses.
Buyer Is responsible to Chambers Truss for towing coats due to site conditions.
6. Price as shown 11 paragraph 7 below Is subject to change H any changes are. made In
this, leyouL A $50 per hour fee for revisions may be charged by Chambers Truss,
7. This is a PURCHASE ORDER to Chambers, Truss of the sum agreed to. or H no,
agreement a reasonable price. Invoice will be made on delivery and paid within term& of net
on delivery. Invoice may, be made at scheduled dateofdelivery If buyer cannot accepi
dallvery of fabricated busses. The undersigned agrees to pay Chambers.Trus& reasonable
attorneys fee for collections In event of payment not timely made. 1.1/2 °h. per month servjce
charge will be added for ail sums not paidwithintome.
8. Signature or Initials anywhere on this sheet constitutes agreement to all tense herein.
9, In ranaldersfjon of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and all Indebtedness owed to
'Chambers Truss by any entity receiving material and the undersignedagreesto pay such
Indatrtednass InGuding a8bmays teas, H default In payment for materiel be made by me
reclPlam.' .
'10. In the event of any litigation concomIng this agreement, the Items furnished hereunder
or payments referred to herein, the parties agree that the able venue for any such action will
be 8eint Wcle County, Fbrids.
I I. Design roeponslNOtiea are per "National Standard And Recommended Guidelines On
Ra. risibillilec For Construction Using Metal Plate Connected Wood Trusses
ANSVTPVVYT'CA 4.2
DATED
,SLONED
FOR TtTt c .M1
gspreader barmaybefeg"per" =14rbprvetdlrl ISidama9s
:. Multiple ply busses must be fastened together per engineering
before they are set, failure to do so can rebuitdn roof collapse.
Temporary and permanent bracing are required and can save life
and property and Is the relsFInslbillty of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
.' KomeMustbeaetandbracedpordeslgntopreuarlt"&ft=Q "
Trusses must be set plumb and square
Do not ",set bunks or stack of plywood, roofing material or any
''bthej adbCentrated loads on busses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort'Plercej Florida 34982-8423
800451-5932
Fort Pierce 772'465.2012 Fez 77146b.8711
%tee... rrearh 772.989.2012 Stuart ''772.2883302 '
Py1J.
tC E�
No,
,yr
7E QF
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
ST LUCIE COUNTY
Wind Design Criteria
ASCE 7-2010
Wind Design Method
Main Wind Force Resisting
Roofing Material
Metal Roof
Loading in PSF
Roof R.D.L.
Top Chord Live
20
Top Chord Dead
7 4.2
Bottom Chord Live
10 Non -Concurrent
Bottom Chord Dead
10 3
TOTAL Load
37 7.2
Duration Factor
1.25
Wind Speed
160mph
Top Chord C.B.
Sheeting by builder.
Bottom Chord C.B.
Sheeting by builder.
Highest Mean Height
24'-0"
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2014
R.D.LPRestraminq usaa Loaa t..ts?L.OnIJnuous Cractn
Verify DESIGN CRITERIA shown above with the,,4
building department and your engineer,
Design Criteria is the responsibility of the
Buildinq Designer and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: 74497
Scale: 1 /4 = 1'
344 total trusses, 119 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:,& ff1&1'7
Date:07/17/17 Revised:08/16/17
FOR
GROUP ONE CONSTRUCTION
DESCRIPTION:
20005 SOUTHERN STAR
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
74497
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
M iTek 6 -
RE: 74497 - 20005 Southern Star MiTek USA, Inc.
Site Information: 6904 Parke
ee3East Blvd.
Customer Info: GROUP ONE CONSTRUCTION Project Name: 20005 SOUTHERTf'�`AR36f�o el:
Lot/Block: Subdivision:
Address: 20005 SOUTHERN STAR
City: FORT PIERCE' State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special
Loading Conditions):
Design Code:' FBC2014/TP12007 Design Program: MiTek 20/20 7.6
Wind Code: ASCE 7-10 Wind Speed: 160 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 119 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index -sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of. Professional Engineers Rules.
No.
Seal#
Truss Name
Date
I No.
I Seal#
I Truss Name
Date
1
T11891061
1 A
8/22/17
118
1 T11891078
1 G4
8/22/17
12 1
T11891062
1 A2
1 8/22/17
119
1 T11891079
1 G5
1 8/22/17
13 1
T11891063
1 ATA
1 8/22/17
120
1 T11891080
1 G6
18/22/17 1
14 1
T11891064
1 D
1 8/22/17
121
1 T11891081
1 G7
1 8/22/17 1
15
1 T11891065
1 D1 1
8/22/17
122
1 T11891082 1
G8 1
8/22/17 1
6
1 T11891066
1 D2
8/22/17
123
1 T11891083
1 G9
8/22/17
17
1 T11891067
D3
1 8/22/17
124
1 T11891084
1 G R5
1 8/22/17
18
1 T118910681
D4
1 8/22/17
125
1 T11891085
1 G RA
1 8/22/17
19
1 T11891069
1 D5
1 8/22/17
126
1 T11891086
1 GRA1
1 8/22/17
110
1 T11891070
1 D6
1 8/22/17
127
1 T11891087
1 G RC
1 8/22/17
Ill J
T11891071
1 D7
1 8/22/17
128
1 T11891088
1 GRD
1 8/22/17
112
1 T118910721
E
1 8/22/17
129
1 T11891089
1 GRE
1 8/22/17
113
1 T11891073
1 F
1 8/22/17
130
1 T11891090
1 GRF
1 8/22/17
114
1 T11891074
1 G
1 8/22/17
131
1 T11891091
1 GRF1
1 8/22/17
15
1 T11891075
G1
8/22/17
132
1 T11891092
1 GRG
8/22/17
116
1 T11891076
1 G2
1 8/22/17
133
1 T11891093
1 GRH
1 8/22/17
117
1 T11891077
1 G3
1 8/22/17
134
1 T11891094
1 GRK
1 8/22/17
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Lee, Julius
My license renewal date for the state of Florida is February 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certifictition
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSVTPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek's customers
file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
,,��IIILIIIIOII
&luS
E N S �' i��i
• �•. '.
.•'
:
No 3486.9
='fl
; Jz---
F •
6904 Parke East Blvd. Tampa FL 33610
Date:
August 22,2017
Lee, Julius 1 of 2
.4
RE: 74497 - 20005 Southern Star
Site Information:
Customer Info: GROUP ONE CONSTRUCTION Project Name: 20005 SOUTHERN STAR Model:
Lot/Block: Subdivision:
Address: 20005 SOUTHERN STAR
City: FORT PIERCE State: FL
No.
Seal# I
Truss Name I
Date I
No. I
Seal# I
Truss Name
I Date
35
T11891095 1
GRK1
8/22/17 178
1
T11891138
M2
8/22/17
36
T11891096 1
GRL
8/22/17 179
1
T11891139
M3
8/22/17
137 1
T11891097 1
GRM 1
8/22/17 180
1
T118911401
M4
1 8/22/17 J
138 1
T11891098 1
GRN 1
8/22/17 181
1
T11891141 1
M5
1 8/22/17 J
139 I
T11891099 I
J1 1
8/22/17 182
1 T118911421
M6
1 8/22/17 J
140 J
T11891100 1
J3 1
8/22/17 183
1 T11891143
1 M7
1 8/22/17 J
141 I
T11891101 I
J3A 1
8/22/17 184
1 T11891144
1 M8
1 8/22/17 1
142 I
T11891102 I
J3B
1 8/22/17 185
1 T11891145
1 MV2
1 8/22/17 J
143 1
T11891103
1 J4A
1 8/22/17 186
1 T11891146
1 MV4
1 8/22/17 J
144 I
T11891104
I J4B
1 8/22/17 187
1 T11891147
1 MV6
1 8/22/17 J
145 I
T11891105 I
J5
1 8/22/17 188
1 T11891148
1 MV8
1 8/22/17
146 I
T11891106 I
J5A
1 8/22/17 189
1 T11891149
1 MV10
1 8/22/17 J
147 I
T11891107 I
J5C
1 8/22/17 190
1 T11891150
1 MV12
1 8/22/17 J
148 I
T11891108 I
J7
1 8/22/17 191
1 T11891151
1 N
1 8/22/17 J
149 I
T11891109
1 JA3
1 8/22/17 192
1 T118911521
N 1
1 8/22/17 J
150
T11891110
1 JC5
1 8/22/17
193
1 T118911531
N2
1 8/22/17 J
151
T11891111
1 JC7
1 8/22/17
194
1 T11891154
1 N3
1 8/22/17 J
152
I T11891112
1 JE
1 8/22/17
195
1 T11891155
1 N4
1 8/22/17
153
I T11891113
1 JE3
1 8/22/17
196
1 T11891156
1 N5
1 8/22/17
154
I T11891114
1 JF
1 8/22/17
197
1 T118911571
N6
1 8/22/17
55
IT118911151JG
8/22/17
198
1 T11891158
N7
8/22/17
156
I T11891116
JK
1 8/22/17
199
1 T11891159
1 N8
8/22/17
157
I T11891117
1 JL
1 8/22/17
1 100
1 T11891160
1 PBA
1 8/22/17
158
1 T11891118
1 K
1 8/22/17
1 101
1 T11891161
1 PBB
1 8/22/17
159
T11891119
1 K1
1 8/22/17
1 102
1 T118911621
PBC
1 8/22/17
160
T11891120
1 K2
1 8/22/17
1 103
1 T118911631
PBD
1 8/22/17 J
161
T11891121
1 K3
1 8/22/17
1 104
1 T118911641
PBE
1 8/22/17 J
162
1 T11891122
1 K4
1 8/22/17
1 105
1 T118911651
PBF
1 8/22/17 J
163
1 T11891123
1 K5
1 8/22/17
1 106
1 T11891166
1 PBG
1 8/22/17 1
64
1 T11891124
1 KJ4
8/22/17
107
1 T11891167
PBH
8/22/17
1 65
T11891125
KJ7
8/22/17
108
1 T11891168
1 PBK
1 8/22/17 J
166
1 T11891126
1 KJ8
1 8/22/17
1 109
1 T118911691
PBL
1 8/22/17 1
167
1 T11891127
1 KJC7
1 8/22/17
1 110
1 T118911701
PBM
1 8/22/17 J
168
1 T11891128
1 KJE
1 8/22/17
1 111
1 T11891171
1 PBN
1 8/22/17 J
169
1 T11891129
1 KJE5
1 8/22/17
1 112
1 T118911721
PBO
1 8/22/17 J
170
1 T11891130
1 KJF
1 8/22/17
1113
1 T118911731
PBP
1 8/22/17 J
71
1 T11891131
KJG
8/22/17
1114
1 T11891174
1 V4
8/22/17
172
1 T11891132
1 KJK
1 8/22/17
1 115
1 T11891175
1 V8
1 8/22/17
173
1 T11891133
1 KJL
1 8/22/17
1 116
1 T11891176
1 VA
1 8/22/17
174
I T11891134
1 L
1 8/22/17
1 117
1 T11891177
1 VB
1 8/22/17
175
1 T11891135
1 Li
1 8/22/17
1 118
1 T11891178
1 VC
1 8/22/17
176
1 T11891136
1 M
1 8/22/17
1 119
1 T11891179
1 VD
1 8/22/17
177
1 T11891137
1 M 1
1 8/22/17
2of2
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891061
74497
A
HIP
1
1
Job Reference op tional
Chambers Truss; Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:30 2017 Page 1
I D:04141 DCB7QwRG?h?eJ CrfKzY77F-dQQbDG5zbJ BgQZH RXBJwkeTcsOGM?F4Z78zVgwylJtJ
1-3-13 5-10-9 10-0-0 14-11-4 19-0-11 z3-7-Z za-11.4
4-1-7 4-11-4 4-1-7 4-6-12 1-3.13
q
0
Scale = 1:43.7
48 =
4x5 =
20 4 5 21
13 is w g
3x4 =3X6 3x8 = 3X4
3x4 = 6x10 // =
1-3-13
24-11-4
1-0-0 10-0-0 14-11-4
23-7-7 23 11 4
1-D-0 8-8-3 4-11.4
8.8-3 - 3
0-3-13
1-0-0
Plate Offsets (X,Y)--
f2:0-7-9 0-3-01 (4:0-5-4 0-2-01 (9:0-7-9 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.23
Vert(LL)
-0.10 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.40
Vert(TL)
-0.27 12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
W B 0.48
Horz(TL)
0.04 9 n/a n/a
BCDL 10.0
Code FBC2014/fP12007
(Matrix-M)
Wind(LL)
0.0510-12 >999 240
Weight: 133lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 7-11-4 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 13=92310-7-10, 9=923/0-7-10
Max Harz 13=-240(LC 10)
Max Upliftl3_ 616(LC 12), 9= 557(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-417/0, 2-3=-411/239, 3-20=-1038/1044, 4-20=-935/1045, 4-5=-886/1016,
5-21=-935/1045, 6-21 =-1 038/1044, 6-7= 420/238, 7-8=-418/26
BOT CHORD 1-13=-50/325, 12-13=-857/1097, 11-12=-588/917, 10-11=-588/917, 9-10=-652/988,
8-9=-62/326
WEBS 2-13=-255/537, 3-13= 840/960, 3-12=-224/329, 4-12= 142/265, 5-1 0=-1 46/265,
6-10=-226/329, 6-9=-839/960, 7-9=-256/537
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 10-0-0, Exterior(2) 10-0-0 to
14-11-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 13=616,
9=557.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10103,2015 BEFORE USE
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Welk'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891062
74497
A2
ROOF TRUSS
1
t
�
Job Reference (optional)
bars r russ,' Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:30 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-dQQbDG5zbJ8gQZHRXBJwkeTYo08z?FEZ78zVgwylJtJ
i 1-3-13 8-5-10 12.5-10 16-510 23-7-7 24-11-0
L� 1-3.13 7-1-13 4-0-0 4-0-0 7.1.13 - 1-3-13
15
3x5 i
5x8 =
4x8 =
11
5x8 =
Scale = 1:44.2
- M
T�
0
10
3x5
1-3-13
1-0-0 8-5-10 16-5.10 23-11-4 i24.11.1 i
1-0-0 7.1.13 B-0-0 7.5.10
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL
I
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
0.40 12-13
>674
360
TCDL
7.0
Lumber DOL
1.25
BC 0.93
Vert(TL)
0.71 12 13
>377
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.47
Horz(TL)
0.03 10
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
-0.38 13-15
>709
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
BOT CHORD
JOINTS
REACTIONS. (lb/size) 15=1066/0-7-10, 10=1066/0-7-10
Max Harz 15=-293(LC 10)
Max Upliftl5=-506(LC 12), 10=-448(LC 12)
Max Gravl5=1237(LC 18), 10=1237(LC 19)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-438/113, 2-23=-1743/752, 3-23=-1646/776, 3-4=-1429/820, 6-7= 1425/820,
7-26=-1642/776, 8-26=-1738/752, 8-9=-386/112
BOT CHORD 1-15=-309/486, 14-15=-311/377, 13-14=-311/377, 12-13=-453/1517, 11-12=-309/447,
10-11= 309/447, 9-10=-309/447
WEBS 2-15_ 1494/1156, 2-13=-195/1145, 3-13=0/402, 7-12=0/402, 8-12= 195/1110,
8-10=-1484/1156, 4-16=-1537/1035, 6-16=-1537/1035
PLATES GRIP
MT20 244/190
Weight: 122 lb FT = 20%
Structural wood sheathing directly applied or 5-2-10 oc puriins.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 12-13.
1 Brace at Jt(s): 16
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=15011; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-6-1, Interior(1) 9-6-1 to 12-5-10, Exterior(2) 12-5-10 to
22-0-13 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 120.0Ib AC unit load placed on the top chord, 12-5-10 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
tit between the bottom chord and any other members.
6) Ceiling dead load (5.0 psf) on member(s). 3-4, 6-7, 4-16, 6-16
7) Bottom chord live load (30.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-13
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except Qt=lb) 15=506,
10=448.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 10/03,2015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage., delivery, erection and bracing of trusses and truss systems, seeANS,/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891063
74497
ATA
ROOF TRUSS
8
1
Job Reference (optional)
Chambers Truss, ' Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:31 2017 Page 1
1 D:O4141 DCB7QwRG?h?eJCrfKzY77F-5c_Rb6cMdHXljsd5vg9Hr?jYP UCki0iMoi2DNylJ11
1-3-13 8-5.10 12-5-10 16-5-10 23-7-7 24-11-4
1-3-13 7-1-13 4-0-0 4-0-0 7-1-13 1-3.13
Scale = 1:43.9
3x6 =
lU
15 3x5
3x5 -�-
5x8 =
5x8 =
1-3-13
1-0-0
6-5-10
165.10
23-11-4 24-11-4
1.0-0
7d-13
8-0.0
7.5-10 1-0-0
Plate Offsets (X,Y)--
11:0-2-10 0-1-8) f2:0-3-4 0-1-41
f5:0-3-0 Edge) f8:0-3-4 0-1-41
(9:0-2-10 0-1-8j
f11:0-2-4 0-3-41
f14:0-2-4 0-3-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.49
Vert(LL)
-0.40 12-13
>674
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.93
Vert(TL)
-0.71 12-13
>377
240
BCLL 0.0
Rep Stress Incr YES
W B 0.47
Horz(TL)
0.03 10
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
-0.38 13-15
>707
240
Weight: 121 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
BOT CHORD
WEBS
REACTIONS. (lb/size) 15=1066/0-7-10, 10=1066/0-7-10
Max Horz 15=-299(LC 10)
Max Upliftl5=-506(LC 12), 10=-448(LC 12)
Max Grav 1 5=1 236(LC 18), 10=1236(LC 19)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-440/114, 2-22=-1745/754, 3-22=-1648/778, 3-4=-1431/822, 6-7=-1427/822,
7-25= 16441778,6-25=-1740/754,8-9= 387/113
BOT CHORD 1-1 5=-310/488,14-15=-309/379, 13-14=-309/379, 12-13=-453/1518, 11-12= 310/448,
10-11=-310/448, 9-10= 310/448
WEBS 2-15=-1494/1157, 2-13=-194/1145, 3-13=0/402, 7-12=0/402, 8-12— 194/1109,
8-10=-1484/1157, 4-6=-1581/1018
Structural wood sheathing directly applied or 5-2-10 oc puffins.
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
2-2-0 oc bracing: 12-13.
1 Row at midpt 4-6
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-6-1, Interior(1) 9-6-1 to 12-5-10, Extedor(2) 12-5-10 to
22-0-13 zone; cantilever left and right exposed ;C-C. for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 120.01b AC unit load placed on the top chord, 12-5-10 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Ceiling dead load (5.0 psf) on member(s). 3-4, 6-7, 4-6
7) Bottom chord live load (30.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-13
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 15=506,
10=448.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verily the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
B always required for stability and to prevent collapse wtlh possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSf/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
2aoo5 Southern Star
T11891064
74497
D
SPECIAL
1
1
Job Reference (optional)
hambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:32 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-ZpYMex7E7xPOftRgecMOg3YgPpwrT4FsbSSclpylJtH
i 1
10-3 15-6-10 i 23-3-2 30-11-9 38-9-12
7-10-3 7-8-7 7-8-7 7.8-7 7-10-3
Scale = 1:67.9
4x6 = 3x4 = 3x6 = 3x4 = 3x4 II 3x6 = 3x4 = 4x6 =
1 2 17 3 18 4 5 196 20 7 8
16 15 14 13 12 11 10 9
3x6 I I 3x8 = 3x6 3x4 = 3x8 = 3x6 3x8 = 3x6 I I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.74
Vert(LL)
-0.19 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.46
Vert(TL)
-0.50 12-13 >932 240
BCLL 0.0
Rep Stress inor YES
W B 0.82
Horz(TL)
0.08 9 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.29 12-13 >999 240
Weight: 223lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-2-2 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-2-14 oc bracing.
WEBS
1 Row at midpt 1-16, 8-9, 1-15, 2-13, 4-12, 7-12, 8-10
REACTIONS. (lb/size) 16=1425/Mechanical, 9=1425/Mechanical
Max Upliftl6— 863(LC 12), 9=-863(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown,
TOP CHORD 1-16=-1355/1146, 1-2=-1818/1405, 2-17=-2673/1990, 3-17=-2673/1990, 3-18=-2673/1990,
4-18= 2673/1990, 4-5=-2672/1990, 5-19= 2672/1990, 6-19= 2672/1990,
6-20= 2672/1990, 7-20= 2672/1990, 7-8=-1818/1405, 8-9= 1355/1146
BOT CHORD 14-15=-1405/1818, 13-14=-1405/1818, 12-13=-1990/2673, 11-12= 1405/1818,
10-11=-1405/1818
WEBS 1-15= 1651/2142, 2-15=-1012/962, 2-13=-763/1022, 4-13=-409/463, 5-12=-408/449,
7-12= 763/1021, 7-10=-1012/962, 8-10=-1652/2142
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=l lfh Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 9-8-15, Interior(1) 9-8-15 to 38-8-0 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 16=863,
9=863.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE 11,1I1-7473 rev. 10/012015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mire
k'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891065
74497
D1
SPECIAL
1
1
Job Reference (optional)
/.OYV a Heg 10 ZV I r MI I eK rnuusrrres, Inc. I Ere Hug zz 1 zui r rage 1
I D:04141 DC87QwRG?h?eJCrfKzY77F-1?6krH7suEXFH 1 0OCKtdMG5?ZDHMCYv?g6B9H FyiJtG
7-10-3 15-6-10 23-3-2 30-11-9 38-9-12
7-10-3 7-8-7 7-8-7 7-8-7 7-10-3
Scale = 1:67.9
4x5 = 3x4 = 3x6 = 3x4 = 3x4 II 3x6 = 3x4 = 4x5 =
1 2 17 3 18 4 5 196 20 7 8
16 21 15 22 14 13 23 12 11 24 10 25 9
3x6 II 4x5 — 3x6 = 3x4 = 3x8 — 3x6 = 4x5 — 3x6 II
i 7-310-3 15-6-10
23�-2
30-11-9 , 38-9-12
7-10-7-8-7
7-8-7
7-8-7 7-10-3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.72
Vert(LL)
-0.17 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.44
Vert(TL)
-0.41 12-13 >999 240
BOLL 0.0
Rep Stress Incr YES
W B 0.73
Horz(TL)
0.07 9 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.2212-13 >999 240
Weight: 237lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-7-4 oc puriins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-8-12 oc bracing.
WEBS
1 Row at midpt 1-16, 8-9, 1-15, 2-13, 4-12, 7-12, 8-10
REACTIONS. (lb/size) 16=1425/Mechanical, 9=1425/Mechanical
Max Upliftl6=-863(LC 12), 9=-863(LC 12)
Max Grav 16=1 474(LC 17), 9=1463(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16=-1356/1146, 1-2=-1536/1174, 2-17=-2244/1662, 3-17=-2244/1662, 3-18=-2244/1662,
4-18=-2244/1662, 4-5=-2231/1662, 5-19=-2231/1662, 6-19= 2231/1662,
6-20=-2231/1662, 7-20=-2231/1662, 7-8=-1523/1174, 8-9= 1356/1147
BOT CHORD 15-22=-1174/1536, 14-22=-1174/1536, 13-14= 1174/1536, 13-23=-1662/2244,
12-23=-1662/2244, 11-12= 1174/1523, 11-24=-1174/1523, 10-24=-1174/1523
WEBS 1-15=-1470/1926, 2-15= 1013/964, 2-13=-677/907, 4-13=408/463, 5-12=-408/449,
7-12=-676/906, 7-10= 1013/964, 8-10=-1470/1910
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=241t; B=150ft; L=100ft; eave=lift Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 9-8-15, Interior(1) 9-8-15 to 38-8-0 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Refer to girders) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 16=863,
9=863.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Sheet, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891066
74497
D2
MONO HIP
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:33 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-1?6krH7suEXFH 10OCKtdMG5_ID FPCVY?g6B9HFyIJtG
13-0-0 21-7-13 30-1-15 38-9-12
6-11-11 6-0-6 8-7-13 8-6-1 8-7-13
Scale = 1:68.0
5x6 =
3x4 = 4x6 = 3x4 = 4x6 =
4 21 5 22 623 24 7 8
15 14 13 25 12 2611 10 27 9
4x10 3x4 ll 4x6 = 3X4 = 3X6 = 4x5 = 3x6 �l
3x8 =
6-11-11
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.83
Vert(LL) -0.19
12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.57
Vert(TL) -0.46
12-13 >999 240
BCLL 0.0 '
Rep Stress Incr
YES
W B 0.94
Horz(TL) 0.09
9 n/a nla
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL) 0.20
12 >999 240
Weight: 227lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-10-14 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-0-8 oc bracing.
SLIDER Left 2x6 SP No.2 2-6-0
WEBS
1 Row at midpt 8-9, 5-13, 7-12, 8-10
REACTIONS. (lb/size) 1=1431/Mechanical, 9=1 431 /Mechanical
Max Horz 1=386(LC 12)
Max Upliftl=-828(LC 12), 9=-904(LC 12)
Max Gravl=1550(LC 17), 9=1572(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-540/264, 2-3=-2532/1975, 3-20=-2209/1755, 4-20=-2151/1767, 4-21 =-1 966/1674,
5-21 =-1 966/1674, 5-22= 2163/1796, 22-23= 2163/1796, 6-23=-2163/1796,
6-24=-2163/1796, 7-24=-2163/1796, 7-8=-1527/1206, 8-9=-1414/1249
BOT CHORD 1-15=-2117/2294, 14-15=-2117/2294, 13-14=-2117/2294, 13-25_ 1796/2163,
12-25=-1796/2163, 12-26=-1206/1527, 11-26=-1206/1527, 10-11=-1206/1527
WEBS 3-13=-406/550, 4-13=-341/585, 5-13=-449/201, 5-12=-316/545, 7-12=-771/826,
7-10= 975/1045,8-10=-1544/1955
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100fh eave=11ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 13-0-0, Exterior(2) 13-0-0 to
26-6-15 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) 1=828,
9=904.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED M1rEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Te k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI l Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312 Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891 os7
74497
D3
MONO HIP
t
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:34 2017 Pagel
I D:04141 DCB7QwRG?h?eJCrfKzY77F-W Bg63d8UfYf6uBaCm 1 OsvUd8CdbwxyM92mxighylJtF
8-2-0 15-0-0 22-11-13 i 30-9-15 38-9-12
8-2-0 6.10-0 7-11-13 7-10-1 7-11-13
6.00 12
Scale = 1:68.2
5x6 =
3x4 = 3x6 = 3x4 = 4x5 =
4 5 22 623 7 8
15 14 13 24 12 11 10 25 9
4x10 11
3x4 I I 3x6 = 3x8 = 3x4 = 3x6 = 4x4 = 3x6 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.79
Vert(LL)
-0.17 12-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.55
Vert(TL)
-0.40 12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.91
Horz(TL)
0.09 9 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.18 13-15 >999 240
Weight: 237lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-8-13 oc puffins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-0-2 oc bracing.
SLIDER Left 2x6 SP No.2 2-6-0
WEBS
1 Row at midpt 8-9, 3-13, 5-13, 7-12, 7-10, 8-10
REACTIONS. (lb/size) 9=1431/Mechanical, 1 =1 431 /Mechanical
Max Harz 1=445(LC 12)
Max Uplift9=-916(LC 12), 1=-817(LC 12)
Max Grav9=1607(LC 17), 1=1570(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-20= 618/58, 2-20= 614/60, 2-3=-2556/1935, 3-21= 2109/1615, 4-21=-2039/1638,
4-5=-1865/1590, 5-22=-1889/1541, 22-23= 1889/1541, 6-23— 1889/1541, 6-7=-1889/1541,
7-8=-1285/1021, 8-9=-1457/1277
BOT CHORD 1-15=-2165/2328, 14-15= 2166/2327, 13-14=-2166/2327, 13-24= 1541/1889,
12-24=-1541/1889, 11-12=-1021/1285, 10-11=-1021/1285
WEBS 3-15=0/250, 3-13= 569/701, 4-13=-309/539, 5-13=-269/121, 5-12=-404/600,
7-12=-773/866, 7-1 0=-1 011/1092, 8-1 0=-1 446/1820
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCD L=3.Opsf; h=24ft B=150ft; L=100f; eave=l1fh Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-0-0, Exterior(2) 15-0-0 to
28-6-15 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 9=916,
1=817.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the appllcabllity of design parameters and properly Incorporate This design Into the overall
building design. Bracing Indicated Is To prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse vrith possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job ,
Truss
russ Type
Qty
Ply
20005 Southern Star
T11891068
74497
D4
MONO HIP
1
1
Job Reference (optional)
s 1 russ, von Pierce, vL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:41:35 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-_OEUGz96QsnzW L90Klv5RhAlg 1 xjgPQI HQgGMByIJtE
8-6-0 17-0-0 24-3-13 31-5-15 38-9-12
8-6-0 8-6-0 7-3-13 7-2-1 7-3-13
Sx8 =
6.00 F12
3x4 = 3x6 = 3x4 =
6 23 7 24 8
Scale = 1:68.1
4x5 =
16 15 14 25 73 12 26 11 27 10
4x10 II 3x4 II 4x6 = 3x8 = 3x4 = 4x4 = 3x6 II
3x6 =
8-6-0
17-"
24-3-13
i 31-5-15 i 38-9-12
8-6-0
8-6-0
7-3-13
7-2-1 7-3-13
Plate Offsets (X,Y)--
f1:0-6-4,Edgel, f5:0-5-0,0-2-01, f12:0-2-3,0-1-81
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.87
Vert(LL)
-0.16 13-14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.58
Vert(TL)
-0.46 14-16 >999 240
BCLL 0.0 '
Rep Stress Incr
YES
W B 0.92
Horz(TL)
0.09 10 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.2014-16 >999 240
Weight: 247lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-10-8 oc bracing.
SLIDER Left 2x6 SP No.2 2-6-0
WEBS
1 Row at midpt 9-10, 3-14, 6-14, 6-13, 8-13, 8-11, 9-11
REACTIONS. (lb/size) 10=1431/Mechanical, 1=1431/Mechanical
Max Harz 1=504(LC 12)
Max Upliftl0=-929(LC 12), 1= 804(LC 12)
Max Grav10=1636(LC 17), 1=1582(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-612/135, 2-21=-2597/1895, 3-21= 2483/1920, 3-22=-1999/1482, 4-22=-1977/1483,
4-5=-1910/1512, 5-23=-1755/1508, 6-23=-1755/1508, 6-7= 1650/1337, 7-24=-1650/1337,
8-24=-1650/1337, 8-9— 1087/871, 9-10— 1496/1306
BOT CHORD 1-16=-2238/2389, 15-16=-2238/2389, 14-15=-2238/2389, 14-25=-1337/1650,
13-25=-1337/1650, 12-13= 871/1087, 12-26=-871/1087, 11-26=-871/1087
WEBS 3-16=0/306, 3-14=-733/837, 5-14= 206/449, 6-14=-275/241, 6-13=-495/651,
8-13=-780/908, 8-11= 1066/1140, 9-11=-1389/1732
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 17-0-0, Exterior(2) 17-0-0 to
30-6-15 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 10=929,
1=804.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MD'EKREFERANCE PAGE MII-7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312 Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891069
74497
D5
MONO HIP
i
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:41:36 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-SaosUJAkB9vg8UkbtSQK_vjSrQFTPrzRW4QpuayiJtD
i 6-6-5 13.0-15 19-0-0 25-7-13 32--15 , -9-12 ,
6-6-5 61 38
-6-9 Al-1 6-7-13 6-6-1 6-7-13
6.00 12
3x4 =
5x6 =
3x6 = 3x4 = 4x5 =
6 24 7 8 25 926 10
17 16 27 28 15 29 14 13 30 12 31 11
3x4 = 46 =
5x8 If
3x8 = 3x4 =
3x6 =
32-1-15
4x4 =
3x6 II
Scale = 1:75.6
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.90
Vert(LL)
-0.40 15-17 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.67
Vert(TL)
-0.85 15-17 >546 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.96
Horz(TL)
0.08 11 n/a n/a
BCDL 10.0
Code FB02014ITP12007
(Matrix-M)
Wind(LL)
0.2315-17 >999 240
Weight: 266lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-5-12 oc puffins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directlyappiied or4-7-15 oc bracing.
SLIDER Left 2x6 SP No.2 2-6-0
WEBS
1 Row at midpt 5-15, 7-15, 7-13, 9-13, 9-12, 10-12
2 Rows at 1/3 pts 10-11
REACTIONS. (lb/size) 11 =1 431 /Mechanical, 1=1431/Mechanical
Max Harz 1=563(LC 12)
Max Upliftl l= 943(LC 12), 1=-789(LC 12)
Max Gravll=1704(LC 17), 1=1677(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-492/227, 2-22= 2821/1871, 3-22=-2744/1888, 3-23=-2696/1858, 4-23=-2647/1859,
4-5=-2626/1872, 5-6=-1954/1440, 6-24=-1717/1390, 724=-1717/1390, 7-8=-149611185,
8-25=-149611185, 9-25=-149611185, 9-26=-947/743, 10-26=-947/743, 10-11=-1577/1335
BOT CHORD 1-17=-2298/2603, 16-17=-1923/2207, 16-27= 1923/2207, 27-28= 1923/2207,
15-28=-1923/2207, 15-29= 1185/1496, 14-29=-1185/1496, 13-14=-1185/1496,
13-30=-743/947, 12-30= 743/947
WEBS 3-17=-239/479, 5-17=-387/520, 5-15=-764/825, 6-15=-266/550, 7-15=-377/406,
7-13=-648/719, 9-13— 814/1012, 9-12= 1167/1186, 10-12=-1356/1.729
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=l i ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterlor(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 19-0-0, Exterior(2) 19-0-0 to
32-6-15 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 11=943,
1=789.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING - Verily deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII--7473 rev. 101032015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314,
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891070
74497
D6
MONO HIP
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:41:37 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-wmLFhfBNyT1 hleJnR9xZX6FiMgb?SL3bkk9MQOylJtC
7-2-5 , 14-2-7 21-0-0 26-11-13 32-9-15 , 38-9-12 i
7-2-5 7-0-1 6-9-9 5-11-13 5-10-1 5-11-13
Scale = 1:81.2
5x6 = 3x4 = 3x6 = 3x4 = 4x5 =
6.00 12
6 23 7 8 9 24 10
16 25 26 15 27 14 13 28 12 29 11
5x8 II 5x8 = 3x8 = 3x6 = 3x4 = 4x4 = 3x6 II
LOADING (psf)
TOLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress lncr YES
Code FBC2014[TP12007
CSI.
TC 0.60
BC 0.65
WB . 0.78
(Matrix-M)
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/deft Ud
-0.42 15-16 >999 360
-0.82 15-16 >568 240
0.08 11 n/a n/a
0.2215-16 >999 240
PLATES GRIP
MT20 244/190
Weight: 278lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-6-3 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD Rigid ceiling directly applied or 4-8-14 oc bracing.
10-11: 2x4 SP M 30
WEBS
1 Row at micipt 10-11, 5-15, 7-15, 7-13, 9-13, 9-12
SLIDER Left 2x6 SP No.2 2-6-0
2 Rows at 1/3 pts 10-12
REACTIONS. (lb/size) 11 =1 43110-7-10, 1 =1 431 /Mechanical
Max Harz 1=623(LC 12)
Max Upliftl 1 =-960(LC 12), 1=-773(LC 12)
Max Gravll=1729(LC 17), 1=1679(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-781/132, 2-3=-2796/1811, 3-21=-2610/1692, 21-22=-2596/1701, 4-22= 2550/1704,
4-5=-2484/1718, 5-6=-1796/1299, 6-23=-1571/1278, 7-23=-1571/1278, 7-8=-1301/1042,
8-9=-1301/1042, 9-24=-799/634, 10-24=-799/634, 10-11= 1614/1367
BOT CHORD 1-16=-2286/2603, 16-25=-1885/2165, 25-26= 1885/2165, 15-26= 188512165,
15-27=-1042/1301, 14-27— 1042/1301, 13-14=-104211301, 13-28— 634/799I
12-28=-634/799
WEBS 3-16=-313/542, 5-16=-361/561, 5-15= 893/906, 6-15— 181/455, 7-15=-505/578,
7-13— 778/805, 9-13= 875/1075, 9-12=-1237/1234, 10-12=-1346/1697
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 21-0-0, Exterior(2) 21-0-0 to
34-6-15 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.0psf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 11=960,
1=773.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11--7473 rev. 1010312016 BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown. and Is for an individual building component, not
�
a truss system. Before use, the building designer must vedly the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety information available from Truss Plate Institute, 218 N. Lee Street. Suite 3 1 Z Ajexandda, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20605 Southern Star
T11891071
74497
D7
MONO HIP
4
1
Job Reference (optional)
russ, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:37 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-wmLFhfBNyT 1 hleJnR9xZX6Fj3gcbBLAbkk9MQOyIJtC
1, 3-13, 8-2.9 15-2-9 22-0-1 27.11-14 33-9.15 39-9-12
i-3-13 6 10 12 7.0-0 6-9-8 5-11-13 5-10-1 5 11-13
5x6 =
3x4 = 3x4 = 3x6 = US =
6.00 12 6 24 7 25 8 26 9 10
Scale = 1:78.2
18 it lb zI 2b 15
ZU 14 13 eu
12 61 11
US = 5x8 US =
3x6 = 3x4 =
4x4 = 3x6 II
1-3-13
12-0-7 22-0-1
27-11-14 33-9-15
39-9-I?
-D-0ro 10.8-10 9-11-9
5-it-73 5-10-1
5.17-13
0-3.13
Plate Offsets (X Y)--
f2:0-7-13,0-3-81,f4:0-3-0,Edgel,f6:0-3-0,0-2-01,f17:0-1-12,0-3-41
LOADING (psf)
SPACING- 2-0-0
CS].
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL)
-0.34 15-16 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.61
Vert(TL)
-0.67 15-16 >692 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.77
Horz(TL)
0.08 11 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.1815-16 >999 240
Weight: 288lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 4-5-6 oc puffins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No. 3'Except' BOT CHORD
Rigid ceiling directly applied
or 4-10-12 oc bracing.
10-11: 2x4 SP M 30 WEBS
1 Row at midpt
10-11, 3-18, 5-15, 7-15, 7-13, 8-13, 8-12
2 Rows at 1/3 pts
10-12
REACTIONS. (lb/size) 11=1419/0-7-10, 18=1516/0-7-10
Max Horz 18=652(LC 12)
Max Upliftl1= 952(LC 12), 18=-882(LC 12)
Max Grav11=1716(LC 17), 18=1734(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-655/142, 2-3=-877/575, 3-22= 2556/1649, 22-23=-2550/1651, 4-23=-2489/1661,
4-5=-2430/1676, 5-6=-1767/1279, 6-24=-1547/1262, 7-24= 1547/1262, 7-25= 1287/1031,
8-25=-1287/1031, 8-26= 792/628, 9-26=-792/628, 9-10= 792/628, 10-11=-1600/1356
BOT CHORD 1-18=-296/674, 17-18=-2232/2528, 16-17=-2232/2528, 16-27=-1851/2123,
27-28= 1851/2123, 15-28=-1851/2123, 15-29= 103111287, 14-29=-1031/1287,
13-14= 1031/1287, 13-30=-6281792, 12-30— 628/792
WEBS 2-18=-584/911, 3-18=-1902/1349, 3-16=-279/489, 5-16=-307/550, 5-15= 865/879,
6-15= 167/435, 7-15=-494/557, 7-13=-758/793, 8-13=-863/1061, 8-12=-1226/1224,
10-12=-1335/1682
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft; eave=l lft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 22-0-1, Exterior(2) 22-0-1 to
35-6-15 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a five load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Qt=lb) 11=952,
18=882.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MlTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11691072
74497
E
COMMON
5
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MUek Industries, Inc. Tue Aug 22 11:41:38 2017 Page 1
I D:04141 DC87QwRG?h?eJCrfKzY77F-Ozvdv?B?jn9YNouz?tTo3KowhE 1 etySkzOvwzTylJtB
6-8-13 13-5-10
6-8-13 6-8-13
4x8 II
4x5 =
2x3 11 — =
4x8 11
Scale = 1:25.2
I�
0
1-0-0 1-1-12
6-8-13
12-1-13 1 -5- D 13-5-10
5-7-1
5-5-0 3-1 1-0-0
Plate Offsets (),Y)--
(1:0-0-12 0-11-131(1:0-6-0,0-0-61,(3:0-6-0,0-0-61,(3:0-0-12,0-11-131
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.43
Vert(LL) 0.08
4-13 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.24
Vert(TL) -0.05
4-13 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB
0.13
HOrz(fL) -0.01
3 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 52lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 8-0-4 oc bracing.
WEBS 2x4 SP No.3
WEDGE
Left: 2x6 SP No.2, Right: 2x6 SP No.2
REACTIONS. (lb/size) 3=507/0-7-10, 1=490/0-3-8
Max Harz 1=-161(LC 10)
Max Upllft3— 601(LC 12), 1= 576(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 474/1081, 2-3=-487/1087
BOT CHORD 1-4=-765/363, 3-4=-765/363
WEBS 2-4=-533/209
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=1 ifh Cat.
II; Exp C; Encl., GCp1=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members:
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Ot=lb) 3=601,
1=576.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE MIf--7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIITPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312 Alexandria, VA 22314.
Tampa, FL 33610
Job I
Truss
Truss Type
City
Ply
20005 Southern Star
T11891073
74497
F
COMMON
2
1
Job Reference o tional
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:38 2017 Page 1
I13:04141 DCB7QwRG?h?eJCrfKzY77F-Ozvdv?B?jn9YNouz?tTo3Kov9E?CtvGkzOvwzTylJtB
1.3-13 8-7-10 16-2-8
1-3-13 7-3-13 7-6-14
5x6 =
m
0
ME
Scale: 3/8"_-V
1-00 013- 3
7-3-13
7-6-14
Plate Offsets (X,Y)--
f1:0-1-4 0-0-21 f2:0-3-0 0-0-121
f5.0-6-10 Edge1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL)
-0.08
6-14
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(TL)
-0.15
6-14
>999
240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.33
Horz(TL)
-0.04
5
n/a
n/a
BCDL 10.0
Code FBC2014ITP12007
(Matrix-M)
Wind(LL)
0.11
6-14
>999
240
Weight: 66lb FT=20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 5=553/0-6-14, 8=646/0-7-10
Max Harz 8=-196(LC 10)
Max Uplift5=-329(LC 12), 8=-453(LC 12)
Max Grav5=553(LC 18), 8=646(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-561/127, 2-3— 694/658, 3-4=-598/658, 4-5= 399/17
BOT CHORD 1-8=-344/581, 7-8=-391/534, 6-7=-391/534, 5-6=-391/534
WEBS 2-8= 700/1125, 3-6=-39/302
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members. '
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atJoint(s) except (jt=lb) 5=329,
8=453.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEKREFERANCE PAGE MII--7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek6 connectors. This design is based only upon parameters shown, and Is for an individual building component. not
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job A
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891074
74497
G
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:41:39 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-s9T?6LCdT4H P?yTAZa_1 cXKOOeFdc D3uC2eTVvylJtA
i 7.8-9 15-1-11 18-6-1 i 20-6-1 , 25-10-1 , 30-10-10 i 38-9-12 ,
7-8-9 7-5-1 3-4-6 2-0-0 5-4-0 50
-8 7-11-2
6.00 12
5x8 = 3x4 = 3x6 = 3x4 11
4x8 = 3x8 = 5x6 wB = 3x4 II 6x8 = 6 22 7 8 23 9
19
3x6 I i
/x1u = Mu —
18 17 4x5 = 3x4 = 12
5X10 = 3X4 11 3x4 I I
15-1
38-9-12
Scale = 1:70.1
4x8 =
10
14
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL)
-0.38 15-16 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.71
Vert(TL)
-0.89 15-16 >522 240
BCLL 0.0
Rep Stress Incr YES
W B 0.94
Horz(TL)
0.24 11 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.5615-16 >823 240
Weight: 246lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-2-13 oc purlins, except
BOT CHORD 2x4 SP M 30 -Except'
end verticals.
4-17,9-12: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 3-10-4 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 10-11, 1-18, 16-18, 2-16, 10-13
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 19=1425/Mechanical, 11=1425/Mechanical
Max Harz 19=59(LC 12)
Max Upliftl9— 856(LC 12), 11= 870(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-19=-1357/1171, 1-2=-2192/1741, 2-20— 4233/3327, 3-20=-4233/3327, 3-21=-4233/3327,
4-21=-4233/3327, 4-5=-4286/3362, 5-6=-3737/2940, 6-22=-3041 /2467, 7-22=-3041 /2467,
7-8=-2205/1782, 8-23= 2205/1782, 9-23=-2205/1782, 9-10=-2208/1797,
10-11=-1342/1184
BOT CHORD 17-18=-197/273, 4-16=-316/343, 15-16=-3562/4449, 14-15=-2723/3403,
13-14= 2467/3041, 9-13=-390/515
WEBS 1-18=-1947/2458, 2-18=-1290/1225, 16-18=-1668/1986, 2-16= 1675/2160,
5-15=-1925/1536, 6-15=-1233/1703, 6-14=-455/341, 7-14= 177/426, 7-13= 1061/868,
10-13=-2008/2466
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 9-8-15, Interior(1) 9-8-15 to 20-6-1, Exterior(2) 20-6-1 to
30-1-4 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Qt=lb) 19=856,
11=870.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING - I/erW design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE Mll-7473 rev. 10/03/2815 BEFORE USE
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandra, VA 22314.
Tampa, FL 33610
Job I
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891075
74497
G1
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:40 2017 Page 1
1 D:04141 DCB7QwRGZeJCrfKzY77F-KL1 NJgDFEOPGc62M61VG8ltBG2d FLiN 1 RhO 11 LylJt9
4-10-9 9-0-0 15-1-11 20-6-1 22-6-1 26-10-1 30-10-10 38-9-12
4-10-9 4-1-7 6-1-11 5-4-6 2-0-0 4-4-0 4-0-8 7-11-2
Scale = 1:70.3
3x4 I I
5x6 = 4x6 = 4x6 =
5x8 = 3x4 =
3x4 5x8 = 7 25 8 26 9 10 27 11
I9
18 17 4x8 = 13 12
4x10 II 6x8 = 3x4 11 3x4 I I 6x8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.75
Vert(LL)
-0.25 15-16 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(TL)
-0.63 15-16 >734 240
BCLL 0.0
Rep Stress Incr YES
W B 0.81
Horz(TL)
0.20 12 n/a n/a
BCDL 10.0
Code FBC2014fTP12007
(Matrix-M)
Wind(LL)
0.38 15-16 >999 240
Weight: 246 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins, except
BOT CHORD 2x4 SP M 30'Except'
end verticals.
5-17,10-13: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 4-2-6 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 11-12, 16-18, 4-16, 11-14
SLIDER Left 2x6 SP No.2 2-6-0
REACTIONS. (lb/size) 1 =1 431 /Mechanical, 12=1431/0-7-10
Max Harz 1=327(LC 12)
Max Upliftl=-838(LC 12), 12=-894(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 608/171, 2-3=-2331/2092, 3-4=-2242/1987, 4-23=-3256/2959, 5-23=-3256/2959,
5-24=-3284/2980, 6-24=-3284/2980, 6-7=-2986/2574, 7-25=-2689/2362, 8-25=-2689/2362,
8-26=-1786/1559, 9-26=-1786/1559, 9-10=-1786/1559, 1027=-1789/1569,
11 -27=- 1789/1569, 11-12= 1353/1238 .
BOT CHORD 1-18= 2142/2054, 5-16=-351/462, 15-16=-3041/3397, 14-15=-2071/2314, 10-14=-385/510
WEBS 3-18=-126/275, 16-18=-1803/1860, 4-16=-1314/1539, 6-16= 291/128, 6-15=-1585/1508,
7-15=-933/1138, 8-15=-457/594, 8-14=-827/801, 11-14= 1864/2119
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=16omph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=15oft; L=10oft; eave=liit; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 18-7-3, Interior(1) 18-7-3 to 22-6-1, Exterior(2) 22-6-1 to
32-1-4 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Gt=lb) 1=838,
12=894.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MfTEKREFERANCE PAGE MI1-7473 rev, 10/03/2015 BEFORE USE
�
Design valid for use only with WOO connectors. lNs design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M6Tek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312 Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Type
Qty
Ply
20005 Southern StarT11891076
711111AI
G2
1
1
Job Reference (optional)
russ, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:41 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-oYbIXOEt?hX7EGdYg?OVhyQMZRyO48xAfL7aZny1Jt8
r 5-9-5 11-0-0 15-1-11 { 22-6-1 , 24-6-1 , 30.10-10 38-9-12
r 5-9-5 5-2-11 4-1-11 7-4-6 2-0-0 6-4-9 7-11-2
5x6 = 3X4 11
5x8 = 5x6 =
4X5 = 7 26
27
Scale = 1:70.3
45 =
I?
17 16 15 6X8 = 11 10
4x10 II
3x4 I I 4x10 = 3x4 11 3x4 11 6X8 =
5-9-5 11-0-0 15-1-11 22, 30-10-10 i _ 38-9-12
5-2-11 4-1-11 7-_4 8-4-9 7-11-2
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
TCLL
20.0
Plate Grip DOL
1.25
TC 0.71
Vert(LL)
-0.24 12-13
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.65
Vert(TL)
-0.60 12-13
>773
240
BCLL
0.0
Rep Stress Incr
YES
W B 0.86
Horz(TL)
0.17 10
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.32 13-14
>999
240
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
BOT CHORD 2x4 SP M 30 "Except`
5-15,8-11: 2x4 SP No.3
BOT CHORD
WEBS 2x4 SP No.3
WEBS
SLIDER Left 2x6 SP No.2 2-6-0
REACTIONS. (lb/size) 1=1431/Mechanical, 10=1431/0-7-10
Max Horz 1=386(LC 12)
Max Upliftl=-828(LC 12), 10=-904(LC 12)
Max Gravl=1475(LC 17), 10=1431(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-22=-512/388, 2-22=-495/390, 2-3=-2396/202413-23=-2152/1876, 4-23=-2087/1885,
4-24=-2723/2512, 5-24=-2723/2512, 5-25=-2716/2346, 6-25=-2716/2346, 6-7=-3118/2713,
7-26=-1505/1343, 8-26= 1505/1343, 8-27=-1503/1344, 9-27=-1503/1344,
9-10=-1354/1262
BOT CHORD 1-17= 2155/2179, 16-17= 2155/2179, 5-14=-349/345, 13-14=-2606/2771,
13-28= 1916/2143, 28-29=-1916/2143, 12-29=-1916/2143, 8-12= 447/574
WEBS 3-16= 289/395, 4-16=-329/339, 14-16= 1803/1933, 4-14=-1185/1344, 6-13— 1612/1492,
7-13=-1598/1916, 7-12=-892/782, 9-12= 1701/1896
PLATES GRIP
MT20 244/190
Weight: 255 lb FT = 20%
Structural wood sheathing directly applied or 3-9-12 oc purlins, except
end verticals.
Rigid ceiling directly applied or 4-6-8 oc bracing.
1 Row at midpt 9-10, 5-13, 7-13, 7-12, 9-12
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=111t; Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 11-0-0, Exterior(2) 11-0-0 to
20-7-3, Interior(1) 22-6-1 to 38-8-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=828,
10=904.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verify deslgn parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev, f0/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual (wilding component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mi%k*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcallon, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891077
74497
G3
SPECIAL
1
1
Job Reference (optional)
russ, tort tierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:41:42 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-Hk98kM EVm?fzsPCIEjXkEAyadrKRpdKKu?t76Ey1Jt7
6-11-11 13-0-0 18-9.0 24-6-1 26-6-1 i 32-6-2 38-9-12
' 6-11-11 ' 6-0-6 ' S-9-0 5-9-0 2-0-0 6-0-2 6-3-10
Scale = 1:69.4
5x8 = 3x4 II 4x5 =
5x8 = 5x12 = 7
3x4 128
29
18 " 16 15 81 14 " 12 " 11 10
4x10 11 3x4 11 4x6 = 3x4 = 3x8 = 3x4 I I 3x5 = 4x10 = 3x6 II
3x6 =
6-11-11 13-0-0 18-9-0 24-6-1
2i5 -1
32-6-2 38-9-12
6-11-11 6-0-6 5-9-0 5-9.0
2-0-0
6-0-2 6-3-10
Plate Offsets (X,Y)--
(1:0-3-8,Edgej,j4:0-6-0,0-2-81,f7:0-6-0,0-2-81,
LOADING (pst)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.57
Vert(LL) -0.15
14-15 >999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.57
Vert(TL) -0.36
14-15 >999
240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.71
Hotz(TL) 0.10
10 n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.2114-15
>999
240
Weight: 270lb FT=20!
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 3-10-9 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly
applied or 4-10-12 oc bracing.
SLIDER Left 2x6 SP No.2 2-6-0 WEBS
1 Row at midpt
9-10, 6-12, 7-12, 7-11, 9-11
REACTIONS. (lb/size) 1=1431/Mechanical, 10=1431/0-7-10
Max Harz 1=445(LC 12)
Max Upliftl=-817(LC 12), 10=-916(LC 12)
Max Grav1=1572(LC 17), 10=1577(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-524/257, 2-23=-2578/1936, 3-23=-2550/1954, 3-24= 2241/1728, 4-24=-2181/1741,
4-25=-2175/1783, 5-25=-2175/1783, 5-26=-2175/1783, 26-27=-2175/1783,
6-27=-2175/1783, 6-7=-1821/1434, 7-28=-1035/851, 8-28= 1035/851, 8-29= 1035/851,
9-29— 1035/851, 9-10= 1459/1279
BOT CHORD 1-18_ 2146/2356, 17-18=-2146/2356, 16-17=-2146/2356, 16-30=-1716/2009,
15-30=-1716/2009, 15-31=-1638/2026, 14-31= 1638/2026, 13-14= 1639/2023,
12-13= 1639/2023, 12-32= 1337/1656, 11-32=-1337/1656
WEBS 3-16= 424/524, 4-16_ 265/434, 4-15=-225/414, 5-15=-350/463, 6-15=-327/268,
6-12=-1351/1101, 7-12= 1038/1440, 7-11=-1040/813, 8-11= 383/502, 9-11=-1392/1689
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24fF B=15011; L=100ft; eave=liit; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 13-0-0, Exterior(2) 13-0-0 to
22-7-3, Interior(1) 24-6-1 to 38-8-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) 1=817,
10=916.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGEMII-7473 rev, 1010312015 BEFORE USE.�
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate this design Into the overall
bullding design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlCatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Mexandrla, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891078
74497
G4
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:41:43 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-Iwj WyiF7XJngTZmxoQ2zmNVjOFg4Y1 JT7fchegy)Jt6
I- it
14-11-4 i 20-8-4 i 26-5-5 i 28-5-5� 33-7-2 38-9.0 ,
8-1-5 6-9-15 5-9-0 5-9-0 2-0-0 5-1-14 ' S-1-14 '
Scale = 1:69.2
Sx6 = 3x4 = 4x5 =
5x8 =
3x4 I I 5x6 = 7 26 8 279
17 10 15 <a 14 <a 10 — 72 11 10
4x10 i l
3x4 II 46 = 3x4 = 3x8 = 4x6 = 4x8 = 4x4 = 3x6 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.65
Vert(LL)
-0.19 12-14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.54
Vert(TL)
-0.44 12-14 >999 240
BCLL 0.0
Rep Stress Incr YES
W B 0.86
Horz(TL)
0.09 10 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.19 15-17 >999 240
Weight: 277 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-8-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or4-11-14 oc bracing.
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
WEBS
1 Row at midpt 9-10, 3-15, 6-12, 8-12, 8-11, 9-11
REACTIONS. (lb/size) 10=1428/0-7-10, 1=1428/0-6-14
Max Harz 1=502(LC 12)
Max UpliftlO= 927(LC 12), 1=-802(LC 12)
Max Grav10=1629(LC 17), 1=1586(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-707/315, 2-22=-2576/1839, 3-22=-2467/1852, 3-23=-2130/1561, 4-23=-2060/1584,
4-5=-1943/1536, 5-24=-1943/1536, 24-25=-1943/1536, 6-25=-1943/1536, 6-7= 1503/1141,
7-26=-1349/1068, 8-26=-1349/1068, 8-27=-796/644, 9-27=-796/644, 9-10=-1526/1303
BOT CHORD 1-17=-2127/2364, 16-17= 2128/2362, 15-16=-2128/2362, 15-28=-1622/1903,
14-28=-1622/1903, 14-29=-1351/1672, 13-29=-1351/1672, 13-30= 1351/1672,
12-30=-1351/1672, 12-31=-644/796, 11-31= 644/796
WEBS 3-17=0/257, 3-15= 566/633, 4-15=-323/508, 4-14=-122/265, 5-14=-345/462,
6-14= 456/502, 6-12=-1286/1118, 7-12= 289/488, 8-12=-876/1141, 8-11=-1258/1189,
9-11=-1322/1634
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100ft eave=l ift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, interior(1) 9-7-3 to 14-11-4, Exterior(2) 14-11-4 to
24-6-7, Interior(1) 26-5-5 to 38-7-4 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 10=927,
1=802.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
'
Design valid for use only with MITek6 connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891079
74497
G5
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M-iTek Industries, Inc. Tue Aug 22 11:41:44 2017 Fagg 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-D7Hu92Gmlcvh5jL7L8ZCJb2tWf?2HTedLJMEA6ylJt5
i 2-0-12 6.2-4 103-12 16-11-4 , 22-10-0 i 28-5-5 30-5-5 34-7-2 , 38-92
,
2-0-12 4-1-8 4 6-7-8 5-10-12 5-7-4 2-0-0 4-1-14 4-1-14
7xl0 MT1E
5x8 =
6.00
5x6 =
3X4 I I 5x6 = 9
Scale = 1:77.5
4x4 = 3x4 I I
10 11
7x10 = 17 16 — 15 11 — — 13 `- 12
20 3x4 11
8.06 12
4x4 = 3x8 = 3x6 = 4x8 =
22-10-0 30-5-5 1
6x8 =
I9
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress [nor YES
Code FBC2014/TP12007
CSI.
TC 0.73
BC 0.63
WB 0.92
(Matrix-M)
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/defl Ud
-0.24 18-19 >999 360
-0.70 18-19 >657 240
0.28 12 n/a n/a
0.38 18-19 >999 240
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight:301 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly
applied or 2-9-14 oc puriins, except
BOT CHORD 2x4 SP M 30 `Except`
end verticals.
5-17: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied
or4-0-14 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 11-12,
16-18, 6-18, 6-16, 6-15, 7-15, 8-15,
1-20,1-19: 2x4 SP M 30
8-13,
10-13, 10-12
REACTIONS. (lb/size) 12=1423/0-7-10, 20=1425/0-6-14
Max Horz20=558(LC 12)
Max Uplift12= 940(LC 12), 20=-785(LC 12)
Max Gravl2=1642(LC 17), 20=1592(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5243/4515, 2-3=-5125/4545, 3-21=-2952/2154, 4-21=-2878/2167, 4-5= 2876/2169,
5-6=-3028/2453, 6-7— 1699/1311, 7-22= 1699/1311, 22-23=-1699/1311, 8-23=-1699/1311,
8-9=-1203/880, 9-10= 1075/828, 1-20_ 1705/1499
BOT CHORD 18-19= 2976/3276, 5-18= 393/592, 16-24=-1501/1773, 15-24= 1501/1773,
14-15= 1088/1369, 14-25= 1088/1369, 25-26= 1088/1369, 13-26=-1088/1369,
13-27=-483/582, 27-28=-483/582, 12-28=-483/582, 19-20=-957/470
WEBS 3-18=-654/820, 16-18= 1439/1727, 6-18=-1426/1471, 6-16=-91/257, 7-15=-347/459,
8-15=-595/665, 8-13— 1300/1139, 9-13=-207/377, 10-13=-933/1331, 10-12= 1553/1301,
3-19=-1 974/1760,1-19= 3828/4477
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=1001t; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-6 to 9-8-10, Interior(1) 9-8-10 to 16-11-4, Exterior(2) 16-11-4
to 26-6-7, Interior(1) 28-5-5 to 30-5-5 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 20 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 12=940,
20=785.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll--7473 rev. 10703/2015 BEFORE USE.
�
Design valid for use only with Mllek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TP1I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available kom Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply=StarT11891080
G6
SPECIAL1
(optional)
,.�1u11 �ue1a 11usa, r— rw � /.G4U S AUg 1 b ZUl / MI I eK Inousines, Inc. I Ue Aug ZZ 11 :41:45 201 ( rage 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-hJgGNOH03w1 YjtwJvr5Rroa2H3KQOwOmaz5oiZylJt4
32-5-5
6.2-4 1 10-3-12 1 13-7-9 MA 6 i18-11.4 1 24-8-4 1 30-5.5 132-1-6 38-9-0
2.0-12 1 41-8 1 4-1-8 1 3-3-13 1 3-3-13 11-11-14 5-9-0 5-9-0 1-8-1 6-3-11
0-3-15 5x6 Scale = 1:79.1
-1
4x5 =
7x10 MTV
5x6 = 3x4 II 5x6 =
6.00 12 1112
7x10 = 21 20 195x12 = 3x8 = 6x8 = 15 14
24 3x4 I I 4x10 = 3x4 13x4 I I 6x8 =
8.06 F12
I9
2-0-12 10-3-12
13-7-9 16-11.6
18-11-41
24-8-4 1 W-5-5 132-1-61 38-9-0
_--- _ 1
2-0-12 8 3-0
3-3-13 3-3-13
1-11-14
5-9-0 5-9-0 1 8-1 6-7-10
Plate Offsets MY)--
(1:Edge,0-3-81, (8:0-3-0,0-2-01, j12:0-3-0,0-2-01, f16:0-2-8,0-2-41,
f22:0-2-12,Edgej, f23:0-6-4,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/dell Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.73
Vert(LL)
-0.23 22-23 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(TL)
-0.68 22-23 >675 240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
WB 0.91
Horz(TL)
0.32 14 n/a n/a
BCDL 10.0
Code FBC2014/rPI2007
(Matrix-M)
Wind(LL)
0.37 22-23 >999 240
Weight: 328 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly
applied or 2-10-9 oc puffins, except
BOT CHORD 2x4 SP M 30 'Except'
end verticals.
4-21,7-19,11-15: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied
or 4-0-11 oc bracing.
Except:
WEBS 2x4 SP No.3 *Except*
1 Row at midpt 7-18
13-14,1-24,1-23: 2x4 SP M 30
WEBS
1 Row at midpt 13-14, 6-22, 8-18, 8-17,
9-17, 10-17, 10-16,
13-16, 6-20
REACTIONS. (lb/size) 14=1420/0-7-10, 24=1426/0-6-14
Max Horz24=617(LC 12)
Max Uplift14=-957(LC 12), 24= 768(LC 12)
Max Grav14=1562(LC 17), 24=1596(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5094/4490, 2-3=-4976/4510, 3-25=-2931/2062, 25-26=-2867/2073, 4-26=-2859/2077,
4-5— 2897/2178, 5-6-2846/2185, 6-7-2224/1668, 7-8=-2225/1775, 8-27-1635/1258,
9-27=-1635/1258, 9-28=-1635/1258, 10-28=-1635/1258, 10-1 1=-979/729,11-12=-839/738,
12-13=-874/715, 13-14=-150311329, 1-24-1614/1455
BOT CHORD 22-23=-2995/3288, 4-22=-187/274, 18-29=-1527/1779, 29-30=-1527/1779,
17-30= 1527/1779, 17-31=-943/1153, 31-32-943/1153, 16-32-943/1153,
23-24— 852/320
WEBS 3-22= 686/874, 20-22=-1755/2081, 6-22-1298/1445, 8-18-858/1013, 8-17= 236/342,
9-17-357/472, 10-17=-748/937, 10-16-1403/1155, 3-23=-1 991/1613,1-23=-4001/4571,
13-16=-1328/1626, 6-20=-1201/1095, 18-20=-1785/2144
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-6 to 9-8-10, Interior(1) 9-8-10 to 18-11-4, Exterior(2) 18-11-4
to 28-6-7, Interior(1) 30-5-5 to 32-5-5 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 24 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 14=957,
24=768.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- verify destgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1--7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MITek@ connectors. This design Is based only upon parameters shown- and Is for an Individual building component• not
�
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Bullding Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job I
Truss
Truss Type
Qty
Ply
20OD5 Southern Star
T11891081
74497
G7
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:46 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-9VOeakHOgE9PK1 VVVTYcg007D8SgZiNwwpdrLF?ylJt3
2-0-12 6-2-4 10-3-12 13-7-9 16-11-6 20-11-4 26-7-3 32-1-6 32 -5 38-9-0
2-0-12 4-1-8 4-1-8 3-3-13 3-3-13 3-11-14 5-7-15 5�-3 0- - 5 6-3-11
7x10 MT1E
5x6 = Scale = 1:78.2
3x4 11 3x6 = 4x5 = 4x5 =
6.00 12
8 26 9 10 27 11 12
7x10 = 20 19 18 5x12 3x8 = 14 13
=
23 3x4 I 4x10 = 3x4 11 3x4 11 6x8 =
8.06 F12
2-0-12 , 10-3-12
, 13-7-9 116-11-6
20-11-4
26-7-3
i
30-5-5 132-1.61 38-9-0
1
2-0-12 8-3-0
_
3-3-13
3-1r 1-14
5-7-15
3-10-2 1-8-1 ` 6-7-10
Plate Offsets (X Y)--
11:Edge 0-3-81 f8:0-3-0 0-2-01 f15:0-5-8
0-4-0) f21:0-2-12 Edge) (22:0-6-0 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL)
-0.39 16-17
>999
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.62
Vert(TL)
-0.87 16-17
>530
240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
W B 0.93
Horz(TL)
0.31 13
n/a
n/a
BCDL 10.0
Code FBC20141FP12007
(Matrix-M)
Wind(LL)
0.3721-22
>999
240
Weight: 320lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
BOT CHORD 2x4 SP M 30 `Except`
4-20,7-18,11-14: 2x4 SP No.3
BOT CHORD
WEBS 2x4 SP No.3'Except-
12-13,1-23,1-22: 2x4 SP M 30
WEBS
REACTIONS. (lb/size) 13=1420/0-7-10, 23=1426/0-6-14
Max Horz23=617(LC 12)
Max Upllftl3=-957(LC 12), 23— 768(LC 12)
Max Grav 1 3=1 569(LC 17), 23=1615(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-5153/4441, 2-3=-5034/4463, 3-24=-2977/2024, 4-24=-2905/2038, 4-25=-2946/2133,
5-25=-2927/2135, 5-6= 2895/2141, 6-7=-2277/1658, 7-8� 2337/1845, 8-26=-1409/1120,
9-26= 1409/1120, 9-1 0=-1 409/1120, 10-27= 1409/1120, 11-27= 1409/1120,
11-12=-889/740, 12-13= 1501/1338, 1-23= 1632/1440
BOT CHORD 21-22= 2958/3332, 7-17= 256/378, 17-28= 1352/1608, 28-29= 1352/1608,
16-29= 1352/1608, 16-30=-740/886, 15-30= 740/892, 11-15=-1221/1153, 22-23= 823/320
WEBS 3-21— 688/871, 19-21 =-1 73312115, 6-21— 1293/1463, 8-17=-995/1220, 8-16— 405/472,
9-16=-315/417, 11-16= 777/1058, 3-22=-1985/1622, 12-15=-1360/1635, 6-19_ 1243/1077,
17-19= 1745/2260, 1-22=-3957/4625
Structural wood sheathing directly applied or 2-10-4 oc purlins, except
end verticals.
Rigid cefffng directfyappfied or4-1-1 oc bracing. Except:
1 Row at midpt 7-17, 11-15
1 Row at midpt 12-13, 6-21, 8-17, 8-16, 9-16, 11-16, 12-15,
6-19
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-6 to 9-8-10, Interior(1) 9-8-10 to 20-11-4, Exterior(2) 20-11-4
to 30-6-7 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL=10.Opsf.
7) Bearing at joint(s) 23 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=1b) 13=957,
23=768.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MfrEKREFERANCE PAGE MIP7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MITek8 connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fatxicatlorr, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11691082
74497
G8
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:41:47 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-dhyl n4lebXIGyB4i1G7vwDgRzs_4Ug832HaunRylJt2
6-2-4 i 12-7-9 16-11-6 i 20-11-5 i 26-8-1 32-1.6 38-9-0 i
6-2.4 6.5-5 4-3-13 3-11-15 5-8-13 5-5-5 6.7-10
5x6 =
3x4 = 3x6 = 4x5 =
6.00 12
26
27
4x5 =
10
I9
le 16 17 US = 3x4 = 12 11
3x6 = 6x8 =
4x12 I1 3x4 11 3x4 11 6x8 =
7x8 =
26-8-1
Scale = 1:78.7
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FB02014/TP12007
CS1.
TC 0.53
BC 0.73
WB 0.93
(Matrix-M)
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/defl L/d
-0.15 17-18 >999 360
-0.41 17-18 >999 240
0.12 11 n/a n1a
0.23 15-16 >999 240
PLATES GRIP
MT20 244/190
Weight:311 lb Ff"=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-9-11 oc puffins, except
BOT CHORD 2x4 SP M 30 "Except'
end verticals.
5-17,9-12: 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-11-12 oc bracing. Except:
WEBS 2x4 SP No.3 *Except*
1 Row at midpt 9-13
10-11: 2x4 SP M 30
WEBS
1 Row at midpt 10-11, 16-18, 5-15, 7-15, 7-14, 9-14, 10-13
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 11=1428/0-7-10, 1=1428/0-6-14
Max Horz 1=621(LC 12)
Max Upliftl 1 =-958(LC 12), 1=-771(LC 12)
Max Gravll=1577(LC 17), 1=1612(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-723/387, 2-3— 2647/1759, 3-24— 2493/1655, 24-25=-2436/1657, 4-25=-2393/1668,
4-5=-2327/1692, 5-6=-1835/1414, 6-26= 1631/1346, 7-26=-1631/1346, 7-8=-1392/1120,
8-27= 1392/1120, 9-27=-1392/1120, 9-10= 898/740, 10-11=-1516/1340
BOT CHORD 1-19— 2159/2475, 18-19=-2159/2475, 5-16=-619/859, 16-28=-1775/2102,
15-28=-1776/2099, 15-29=-1120/1392, 14-29= 1120/1392, 14-30=-741/897,
13-30=-740/903, 9-13= 1184/1158
WEBS 3-18=-242/465, 16-18= 1908/2198, 4-16=-3B5/407, 5-15=-1006/916, 6-15— 322/552,
7-15=-465/493, 7-14=-685l748, 9-14= 783/1013, 10-13=-1361/1651
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 20-11-5, Exterior(2) 20-11-5 to
30-6-8 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 11=958,
1=771.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M1I--7473 rev. 101032016 BEFORE USE.
Design valid for use only with MITek0 connectors, This design Is based only upon parameters shown, and Is for an Individual building.component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI i Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job 4
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891083
74497
G9
SPECIAL
3
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:41:48 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-5uW P?PJGMrQ7aKfuaze8TRCeRGL1 DH W CGxKSJtylJtl
1-3-1 7-30 13-8-5 16-0-2 22-0-1 27-8-13 332-2 39-9-12
' -3.1 5-11-34-3-13 311.15 6-8-13 5-55 6-7-10
6.00 F12
Sx6 =
3x4 = 3X6 = 4x5 = 4x5 =
7 26 8 9 27 10 11
I9
Scale = 1:78.3
21 2u 114
186x8 = 3x8 =
3x4 =
13 12
4X6 = 7x8 =
3x4 I
3X4 II 6x8 =
3x5 =
1-3-13
1 1o4-8
16-0-2
22-0-1
27-e-13 33-2-2
39-B-12
-0- 9-0-11
7-7-10
3-it-15
5-B-13 5-5-5
6-7-10
0-3-13
Plate Offsets (X Y)--
f2:0-7-13 0-3-81 (7:0-3-0 0-2-0j (14:0-5-8 0-4-0j (17:0-5-8 0-4-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL)
-0.12 16-17 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.69
Vert(TL)
-0.33 18-19 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.93
Horz(TL)
0.12 12 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.2016-17 >999 240
Weight: 318lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing
directly applied or 4-5-11 oc puriins, except
BOT CHORD 2x4 SP M 30 `Except`
end verticals.
6-18,10-13. 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-1-7 oc bracing. Except:
WEBS 2x4 SP No.3 "Except`
1 Row at midpt
10-14
11-12: 2x4 SP M 30
WEBS
1 Row at midpt
11-12, 3-21, 17-19, 6-16, 8-16, 8-15, 10-15,
11-14
REACTIONS. (lb/size) 12=1419/0-7-10, 21=1517/0-7-10
Max Horz 21 =652(LC 12)
Max Upliftl2=-951(LC 12), 21=-882(LC 12)
Max Gravl2=1566(LC 17), 21=1670(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2_ 519/84, 2-3=-700/418, 3-25=-2474/1572, 4-25=-2409/1575, 4-5=-2358/1588,
5-6=-2290/1666, 6-7= 1814/1396, 7-26=-1612/1330, 8-26=-1612/1330, 8-9= 1379/1109,
9-27=-1379/1109, 10-27=-1379/1109, 10-11=-891/735, 11-12=-1504/l331
BOT CHORD 1-21=-182/531, 20-21=-2051/2414, 19-20=-2051/2414, 6-17=-591/830, 17-28= 1750/2073,
16-28= 1751/2068, 16-29= 1109/1379, 15-29=-1109/1379, 15-30=-735/890,
14-30=-734/897, 10-14=-1173/1149
WEBS 2-21=-435/698, 3-21=-1951/1311, 3-19=-215/429, 17-19= 1872/2160, 5-17=-361/361,
6-16=-984/896, 7-16=-313/543, 8-16=-455/480, 8-15=-674/739, 10-15=-773/1001,
11-14= 1351/1639
NOTES-
1) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=Lift Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 22-0-1, Exterior(2) 22-0-1 to
31-7-4 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where,a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 12=951,
21=882.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 11411-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITekb connectors. This design is based only upon parameters shown. and Is for an Individual building component, not
�-
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891084
74497
GRS
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MITek Industries, Inc. Tue Aug 22 11:41:49 2017 page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-Z44nCIKu79Y_BUE58h9NOelv6ggJyxDMVb3?rKylJtO
2-5-4 5-0-0
2-5-4 2-6-12
Scale = 1:19.9
4
3x8 14x4 =
2-5-4
5-0-0 ,
r
2-5-4
2-6-12
Plate Offsets (),Y)--
f1:0-3-8 0-1-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
Vert(LL) -0.00
5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.11
Vert(TL) -0.00
4-5 >999 240
BCLL 0.0 '
Rep Stress Incr NO
W B 0.06
Horz(TL) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.00
5 >999 240
Weight: 36lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins, except
BOT CHORD 2x6 SP No.2
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
SLIDER Left 2x6 SP No.2 2-7-1
REACTIONS. (lb/size) 1=323/0-8-0, 4=268/Mechanical
Max Horz 1=144(LC 8)
Max Upliftl= 106(LC 8), 4=-185(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb)
or less except when shown.
WEBS 2-4=263/195
NOTES-
1) Wind: ASCE 7-10; VUIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; 8=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Qt=lb) 1=106,
4=185.
6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 86 lb down and 43 lb up at 1-1-13,
and 146 Ib down and 59 Ib up at 3-1-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 4-6=-20, 1-3=-54
Concentrated Loads (lb)
Vert: 10=-86(B) 12= 146(B)
© WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/012015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stabllily and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate institute. 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job I
Truss
Truss Type
Qty
Pty
20005 Southern Star
T71691085
74497
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:50 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-2Ge9Q5LWuSgrpepHiOgcYslz8455hFwVkFpYOmyiJt?
12-5-10 16-11-4 20-2-15 23-7-7 24-11-0
411-3-:1313 3.4.8 3-3-11 4-5-10 4.5.10 3-3-11 3-4-B 1-3-13
I
0
4x8 = 2x3 11
4 22 235 24 25
4x8 =
Scale = 1:43.0
15 ,. — ., 10
3x4 = 6x8 3x4 = 3x6 = 3x8 = 3x4 = 6x8 = 3x4 =
1-3-13 24-11-4
i 1-0-0 B-0-0 12-5.10 16-11-4 23-7-7 23r17r4
1-0-0 6-8-3 4-5-10 4-5-10 ' 6-8-3 0�3-43
0-3-13 1-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.40
Vert(LL) -0.08
12 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(TL) -0.17
11-12 >999 240
BCLL 0.0
Rep Stress Incr
NO
WB 0.67
Horz(TL) 0.07
10 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.13
12 >999 240
Weight: 135lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-5-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-2-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 15=1560/0-7-10, 10=1560/0-7-10
Max Harz 15=193(LC 7)
Max Upliftl 5=-1 145(LC 8), 10=-1087(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-270/72, 2-3= 324/191, 3-4=-2282/1694, 4-22= 2434/1871, 22-23=-2434/1871,
5-23= 2434/1871, 5-24= 2434/1871, 24-25=-2434/1871, 6-25= 2434/1871,
6-7=-2282/1698, 7-8=-324/221, 8-9= 270/74
BOT CHORD 14-15=-1287/1837, 14-26=-1392/2024, 13-26=-1392/2024, 13-27=-1392/2024,
12-27— 1392/2024, 12-28=-1329/2024, 28-29=-1329/2024, 11-29= 1329/2024,
10-11— 1273/1837
WEBS 2-15=-257/317, 3-15=1963/1479, 3-14=-370/315, 4-14=-48/373, 4-12=-480/615,
5-12=-552/608, 6-12= 462/590, 6-11= 53/373, 7-11=-382/327, 7-1 0=-1 963/1449,
8-10=-257/302
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=l6omph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=l ift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
15=1145, 10=1087.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s)139 lb down and 333 lb up at 8-0-0,
91 lb down and 175 lb up at 10-0-12, 91 lb down and 175 lb up at 12-0-12, 91 lb down and 175 lb up at 12-10-8, and 91 lb down and
175 lb up at 14-10-8, and 195 lb down and 366 lb up at 16-11-4 on top chord, and 235 lb down and 174 lb up at 8-0-0, 68 lb down and
3 lb up at 10-0-12, 68 lb down and 3 lb up at 12-0-12, 68 lb down and 3 lb up at 12-10-8, and 68 lb down and 3 lb up at 14-10-8, and
235 lb down and 174 lb up at 16-10-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASES) Standard
Loominuea on a e e
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek9 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312- Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T716910115
74497
GRA
HIP
1
1
Job Reference (optional)
Uharnbers truss, ton Fierce, FL
/.09V 5 Aug 10 ZU1 r MI I eK mausines, inc. I ue Aug zz 11:41:*V LV 1 / rage L
I D:04141 DCB7QwRG?h?eJCrf KzY77F-2Ge9Q5LW uSgrpepHiOgcYsiz8455hFwVkFpYOmy)Jt?
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4= 54, 4-6=-54, 6-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert:4=-139(B) 6=-139(B) 14=-235(B)11=-235(B) 22_ 91(B) 23� 91(B)24=-91(B) 25= 91(B) 26=-40(B) 27= 40(B)28= 40(131) 29= 40(B)
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MrrEKREFERANCE PAGE MII--7473 rev- 10/03MOIS BEFORE USE.
Design valid for use only with MITek® connectors. this design is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891086
74497
_
GRA1
COMMON
1
2
Job Reference (optional)
ClTambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:41:50 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-2Ge9Q5LWuSgrpepHiOgcYsIUK42rhFfVkFpYOmylJt?
4-11-3 8-8-7 12-5-10 i 16-2-13 i 20-0-1 23-11-4
4-11-3 3-9-3 3-9-3 3-9-3 3-8-3 3-11-3 r
4xs 11
7x12 -55- 3x6 11 8x10 = 10x10 = 7x8 = 3x6 11 8x12
4-11-3
20-0-1
Scale = 1:43.8
Cr
0
6
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2014/TP12007
CSI.
TC 0.71
BC 0.60
WB 0.69
(Matrix-M)
DEFL. in
Vert(LL) -0.16
Vert(TL) -0.37
Horz(TL) 0.08
Wind(LL) 0.23
(loc) I/deft Ud
9 >999 360
9 >783 240
7 n/a n/a
9 >999 240
PLATES GRIP
MT20 244/190
Weight: 340 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-5-15 oc puffins.
BOT CHORD 2x8 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3'Except*
4-10: 2X4 SP M 30
WEDGE
Left: 2x4 SP No.3, Right: 2x6 SP No.2
REACTIONS. (lb/size) 7=8059/0-7-10, 1=6213/0-7-10
Max Harz 1=-288(LC 6)
Max Uplift7=-4587(LC 8), 1= 3686(LC 8)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-9501/5661, 2-3=-11086/6610, 3-4=-9012/5345, 4-5=-9014/5346, 5-6= 11652/6750,
6-7— 12688/7239
BOT CHORD 1-12=-4941/8379, 12-20=-4941/8379, 11-20= 4941/8379, 11-21=-5748/9905,
21-22=-5748/9905, 10-22=-5748/9905, 10-23=-5876/10418, 9-23=-5876/10418,
9-24=-6360/11221, 8-24=-6360/11221, 8-25= 6360/11221, 7-25=-6360/11221
WEBS 2-12= 1636/979, 2-11 =-1 141/1838, 3-11— 1760/2823, 3-10=-2847/1890, 4-10=-4583/7801,
5-10=-3614/2083, 5-9=-1958/3628, 6-9=982/571, 6-8=-590/1047
NOTES-
1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24fh B=150ft; L=100ft; eave=l ift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=4587,
1=3686.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2628 lb down and 1741 lb up at
8-0-12, 1405 lb down and 790 lb up at 10-0-12, 1427 lb down and 818 lb up at 12-0-12, 1416 lb down and 795 lb up at 14-0-12, 1416
lb down and 795 lb up at 16-0-12, 1416 lb down and 795 lb up at 18-0-12, and 1404lb down and 789 lb up at 20-0-12, and 1404 lb
down and 789 lb up at 22-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
Continued on Daoe 2
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must veilty the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stabillty and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricalion, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891086
74497
GRA1
COMMON
1
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
7.640 S AUg 16 20l 7 MI I eK Inaustrles, Inc. I U9 AUg L'L 11:41:bU'LUl 1 Vage'L
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-2Ge9Q5LW uSgrpepH iOgcYsl uK42rhFfVkFpYOmylJt?
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 4-7=-54, 1-13=-20
Concentrated Loads (lb)
Vert: 9=-1416(F) 8=-1404(F) 20=-2628(F) 21= 1405(F) 22= 1411(F) 23=-1416(F) 24= 1416(F) 25= 1404(F)
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIlEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE,
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quatlby Criteria, DSB-89 and BCSI Bullding Component
6904 Parke East Blvd.
Safety information available from Truss Plate Insfihde, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
4
T11891087
74497
GRC
MONO TRUSS
1
2
Job Reference (optional)
l:namDers truss. port Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:51 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-WTCXdRL9fmoiRoOTG6Br53g6uTNuQe_fzvY6wCyIJt_
i 8-0-12 11-5-14 16-7-13 22-1-4
' 8-0-12 3-5-2 5-1-15 5-5-7
3x4 11 Scale = 1:70.4
6.00 12
4x12 �, 3x6 11 10x10 = 8x10 = 10x10 = 8x10 =
8x12 11
LOADING (psf)
TOLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2014[TP12007
CSI.
TO 0.53
BC 0.61
W B 0.94
(Matrix-M)
DEFL. in (loc) I/defl L/d
Vert(LL) 0.21 10-11 >999 240
Vert(TL) -0.31 10-11 >846 240
Horz(TL) 0.05 7 n/a n/a
PLATES GRIP
MT20 244/190
+
Weight: 373 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-7-1 oc puriins, except
BOT CHORD 2x8 SP 240OF 2.OE
end verticals.
WEBS 2x4 SP No.3 `Except`
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
6-7: 2x6 SP No.2, 5-8,5-7: 2x4 SP M 30
WEBS
1 Row at midpt 6-7, 3-8, 5-7
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 7=7277/0-7-10, 1=5423/0-7-10
Maio Harz 1=648(LC 8)
Max Uplift7=-4908(LC 8), 1= 3351(LC 8)
Max Grav7=7309(LC 2), 1=5423(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-9250/5754, 2-3=-8045/4984, 3-4=-4424/2660, 4-5=-4368/2675
BOT CHORD 1-11= 5612/8162, 11-16=-5612/8162, 10-16= 5612/8162, 10-17=-4818/7187,
9-17=-4818/7187, 9-18=-4818/7187, 8-18=-4818/7187, 8-19= 2623/3907,
19-20= 2623/3907, 20-21= 2623/3907, 7-21= 2623/3907
WEBS 2-11= 1073/1498, 2-1 0=-1 480/1205, 3-10= 3208/4946, 3-8=-4853/3248, 5-8=-5011/7732,
5-7= 7227/4848
NOTES-
1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; 8=150ft; L=1001t; eave=liit; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.60
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 7=4908,
1=3351.
7) "Semi -rigid pitchbreaks including heels Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2628 lb down and 1839 lb up at
8-0-12, 1405 lb down and 883 lb up at 10-0-12, 1419 lb down and 883 lb up at 12-0-12, 1472 lb down and 924 lb up at 14-0-12, 1490
Ito down and 936 lb up at 16-0-12, and 1468 lb down and 949 lb up at 18-0-12, and 1543 lb down and 963 lb up at 20-0-12 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
M#fj bg,#WM,St0ndard
Q WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEk REFERANCE PAGE MII-7473 rev. 10103/2015 BEFORE USE
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property darnage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Sfer
T11891087
74497
GRC
MONO TRUSS
1
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
7.640 s Aug 16 2017 MII eK Industnes, Inc. I ue Aug 22 11:41:51 2017 Page 2
I D:04141 DCB7QwRG?h?eJCrfKzY77F-WTCXdRL9fmoiRoOTG6Br53g6uTNuQe_fzvY6wCylJt_
LOAD CASES) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-6=-54, 1-7=-20
Concentrated Loads (lb)
Veil: 9= 1411(B)11=-2628(B)16=-1405(B)17=-1405(B) 18=-1411(B)19= 1411(B)21=-1411(5)
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE
'
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
bu0tling design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891088
74497
GRD
SPECIAL
1
1
Job Reference (optional)
_............. .....,.........., ..._. ._.-.._a __ ... ...__ __.. . _�_ .
ID:04141DCB7QwRG?h?eJCrfKzY77F-_flwrnMn64w Yzgppj4dHNAatd_99zoBZltRfylJsz
6-6-13 12-11-13 19-4-14 25-9-15 32-2-15 38-9-12
6-6-13 6.5-1 6-5-1 6-5-1 6-6-13
Scale = 1:72.2
3x4 = 5x8 MT18HS =
4x10 = 3x10 = 5x8 MT18HS = 3x4 11 3x4 = 3x10 = 4x10 =
1 17 18 19 220 21 22 3 4 23 24 25 526 27 28 29 30 6 7 31 32 8 33 34 35 9
16 36 37 38 15 39 40 41 14 42 43 13 44 45 46 47 12 48 49 50 11 51 52 53 10
5x8 MT18HS I I 6x8 = 5x8 MT18HS = 3x8 = 5x8 MT18HS = 6x8 = 5x8 MT18HS I I
6-6-13 12-11-13
19-4-15-9-15
2
32-2-15
3a-9-12
6-6-13 fi-5-1
fi-5-4
1
6-5-1
6-5-1
6-6-13
Plate Offsets (X Y)--
f2:0-3-80-1-81 f3:0-4-0 Edgej f7:0-4-0 Edgel
f8:0-3-8 0-1-81 [10:0-3-8
Edge], (11:0-3-8 0-3-01 (12:0-3-12 0-3-01 f14:0-3-12
0-3-01,(15:0-3-8,0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.98
Vert(LL) -0.47
13 >982 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 1.00
Vert(TL) -1.09
13-14 >422 240
MT18HS 244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.70
Horz(TL) 0.20
10 n/a n/a
BCDL 10.0
Code FBC2014lTP12007
(Matrix-M)
Wind(LL) 0.77
13 >601 240
Weight: 219lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly
applied or 2-1-13 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 "Except`
BOT CHORD
Rigid ceiling directly applied
or 3-7-11 oc bracing.
1-15,2-14,4-13,6-13,8-12,9-11: 2x4 SP M 30
WEBS
1 Row at midpt 1-16,
9-10, 1-15, 2-14, 8-12, 9-11
REACTIONS. (lb/size) 16=2702/Mechanical, 10=2648/Mechanical
Max Upliftl 6=-1 866(LC 4), 10=-1819(LC 5)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-16- 2579/1891, 1-17= 3681/2545, 17-18=-3681/2545, 18-19=-3681/2545,
2-19= 3681/2545, 2-20=-5734/3966, 20-21=-5734/3966, 21-22=-5734/3966,
3-22=-5734/3966, 3-4=-5734/3966, 4-23=-6503/4507, 23-24=-6503/4507,
24-25=-6503/4507, 25-26=-6503/4507, 5-26=-6503/4507, 5-27=-6503/4507,
27-28=-6503/4507, 28-29= 6503/4507, 29-30=-6503/4507, 6-30= 6503/4507,
6-7=-5741 /3955, 7-31= 5741 /3955, 31-32=-5741 /3955, 8-32=-5741 /3955,
8-33= 3675/2532, 33-34=-3675/2532, 34-35= 3675/2532, 9-35=-3675/2532,
9-10= 2541/1839
BOT CHORD 15-39= 2545/3681, 39-40=-2545/3681, 40-41=-2545/3681, 14-41=-2545/3681,
14-42=-4008/5780, 42-43= 4008/5780, 43-44=-4008/5780, 13-44= 4008/5780,
13-45=-3990/5780, 45-46= 3990/5780, 46-47=-3990/5780, 12-47= 3990/5780,
12-48_ 2532/3675, 48-49= 2532/3675, 49-50=-2532/3675, 11-50=-2532/3675
WEBS 1-15=-2970/4296, 2-15= 2026/1675, 2-14=-1703/2448, 4-14=-1082/998, 4-13=-680/855,
5-13=-646/763,6-13=-688/855,6-12=-1084/1003,8-12- 1720/2460,8-11=-2024/1667,
9-11=-2956/4290
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
0; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
16=1866, 10=1819.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Continued on page 2
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MI1-7473 rev. 1010MO15 BEFORE USE
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component not
a truss system. Before use, the building designer must vetify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporaryand permanent bracing
M iTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Atexandda. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qfy
P y
20005 Southern Star
T11891088
74497
GRD
SPECIAL
1
1
Job Reference (optional)
t;namDers I russ, ron Pierce, rL
t.64U 5 Aug 16 2U1 I MI I eK Industries, Inc. 1 Ue Aug 22 11:41:52 2017 Page 2
I D:04141 DCB7QwRG?h?eJCrfKzY77F-_flwrnMnQ4wZ3yzgppj4dHNAatd_99zoBZlfRfylJsz
NOTES-
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 91 lb down and 175 lb up at 1-0-0, 91 lb down and 175 lb up at 3-0-0, 91 lb
down and 175 lb up at 5-0-0, 91 lb down and 175 lb up at 7-0-0, 91 lb down and 175 lb up at 9-0-0, 91 lb down and 175 lb up at 11-0-0, 91 lb down and 175 lb up at 13-0-0, 91
lb down and 175 lb up at 15-0-0, 91 lb down and 175 lb up at 17-0-0, 91 lb down and 175 lb up at 19-0-0, 91 lb down and 175 lb up at 21-0-0, 91 lb down and 175 lb up at
23-0-0, 91 lb down and 175 lb up at 25-0-0, 91 lb down and 175 lb up at 27-0-0, 91 lb down and 175 lb up at 29-0-0, 91 lb down and 175 lb up at 31-0-0, 91 lb down and 175 lb
up at 33-0-0, and 91 lb down and 175 lb up at 35-0-0, and 91 lb down and 175 lb up at 37-0-0 on top chord, and 68 lb down and 3 lb up at 1-0-0, 68 lb down and 3 lb up at
3-0-0, 68 lb down and 3 lb up at 5-0-0, 68 lb down and 3 lb up at 7-0-0, 68 lb down and 3 lb up at 9-0-0, 68 lb down and 3 lb up at 11-0-0, 68 lb down and 3 lb up at 13-0-0, 68
lb down and 3 lb up at 15-0-0, 68 lb down and 3 lb up at 17-0-0, 68 lb down and 3 lb up at 19-0-0, 68 lb down and 3 lb up at 21-0-0, 68 lb down and 3 lb up at 23-0-0, 68 lb
down and 3 lb up at 25-0-0, 68 lb down and 3 lb up at 27-0-0, 68 lb down and 3 lb up at 29-0-0, 68 lb down and 3 lb up at 31-0-0, 68 lb down and 3 lb up at 33-0-0, and 68 lb
down and 3 lb up at 35-0-0, and 68 lb down and 3 lb up at 37-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-9=-54, 10-16- 20
Concentrated Loads (lb)
Vert: 14=-40(B) 4=-91(B) 7=-91(B) 17=-91(B) 18= 91(B) 19= 91(B) 20=-91(B) 21=-91(B) 22=-91(B) 24=-91(B) 25=-91(B) 26=-91(13) 27=-91(B) 28=-91(B) 30=-91(B)
31= 91(B) 32=-91(B) 33=-91(B) 34=-91(B) 35= 91(B) 36=-40(B) 37- 40(B) 38= 40(B) 39=-40(B) 40= 40(B) 41=-40(B) 42= 40(B) 43=-40(B) 44=-40(B) 45_ 40(B)
46=-40(B) 47=-40(B) 48= 40(B) 49= 40(B) 50= 40(B) 51=-40(B) 52= 40(B) 53=-40(B) '
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mffek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANST/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
' T11891089
74497
GRE
SPECIAL
1
1
Job Reference (optional)
Ch mbers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:53 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-SrJ127NPAN2Qg6XsNWEJAUwXRHB5uhayQD1Dz5ylJsy
r 1-3-13 5-7-4 , 6-3-2 , 7-2-8 7-10-6 12-1-13 _ 13-5-10
1-3-13 4-3-7 0-7-14 0-11-7 0-7-14 4-3-7 1-3-13
3.64 FIT
4x4 = 4x4 =
4x4 % 4 5 6. 4x4
Scale = 1:24.5
I2T 0
oxw 14 4x4 = 2x3 II 2x3 II 4x4 = 9 ---
3x6 11 3x6 11
5-7-4 , 6-3-2 , 7-2-8 , 7-10-6 , 12-1-13 1�-5-10 13-5-10
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.21
Vert(LL)
0.05 13-14
>999
240
TCDL 7.0
Lumber DOL
1.25
BC 0.12
Vert(TL)
-0.03 13-14
>999
240
BCLL 0.0
Rep Stress Incr
NO
W B 0.36
Horz(TL)
-0.01 9
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 14=665/0-7-10, 9=658/0-7-10
Max Harz 14— 135(LC 6)
Max Uplift14=-778(LC 8), 9=-707(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 741/1117, 3-4=-652/1016, 4-5=-609/952, 5-6=-649/1007, 6-7=-737/1098
BOT CHORD 13-14=-288/144, 12-13= 1039/608, 11-12= 1030/609, 10-11=-1028/605
WEBS 2-14=-568/608, 2-13=-921/501, 7-10= 932/500, 7-9=-568/573
PLATES GRIP
MT20 244/190
Weight: 73 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 or, puffins.
Rigid ceiling directly applied or 7-1-3 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=778,
9=707.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 61 lb down and 170 lb up at 5-7-4,
161 lb down and 549 lb up at 6-3-2, and 90 lb down and 290 lb up at 7-2-9, and 61 lb down and 170 lb up at 7-10-6 on top chord, and
27 lb up at 5-7-4, 30 lb down and 15 lb up at 6-0-0, 26 lb down and 13 lb up at 6-3-2, 35 lb down and 8 lb up at 6-6-3, 35 lb down and
8 lb up at 6-11-7, 26 lb down and 13 lb up at 7-2-9, and 30 lb down and 15 lb up at 7-5-10, and 27 lb up at 7-10-6 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3= 54, 3-4_ 54, 4-5=-54, 5-6=-54, 6-8= 54, 15-18=-20
Concentrated Loads (lb)
Vert: 3=13(F) 4=-161(F) 5=-90(F) 6=13(F) 13=-15(F) 12=-35(F) 11=-35(F) 10= 15(F)
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. f0/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITeW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallon, storage, delivery, erection and bracing of trusses and truss systems, se.eANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891090
74497
GRF
SPECIAL
1
1
Job Reference (optional)
Chambers Truss,' Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:41:54 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-w2tgFTOixhAGIF62xElYiiShZhSUdB65ftnmWXylJsx
s-10-14
5-2-10 i 7-1-10 i 8-4-6 8i7-10 10-1-12 12-1-2 16-2-8
1�-13 3.10-73 1-11-1 1-2-12 3 1-2-14 1-11-6 4-1-6
4.21 12 0-3-14x4 = Scale =1:31.1
4x4 % 23 5 24 6
axa
3x4 = 2x3 I I dxt% = 6M — zX0 I I
1-0-0 1- 3
5-2-10
7-1-10
8-4- -10-1 10-1-12
12-1-2 16-2-8
1-0-0 0-3- 3
3-10-13
1-11-1
1-2-12 0-6-8 1-2-14
1-11-6 4-1-6
Plate Offsets (X,Y)--
f1:0-1-4 0-0-21 f2:0-5-8 0-1-81 f9:0-6-10 Edgel
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in (loc)
I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.31
Vert(LL) 0.08 11-13
>999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC
0.43
Vert(TL) -0.09 11-13
>999 240
BCLL 0.0
Rep Stress Incr
NO
WB
0.15
Horz(TL) -0.02 9
n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 98 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural
wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 6-11-3 oc bracing.
WEBS 2x4 SP No.3
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 9=755/0-6-14, 15=820/0-7-10
Max Harz 15=-180(LC 6)
Max Uplift9=-678(LC 8), 15= 760(LC 8)
Max Grav9=771(LC 18), 15=852(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 921/833, 2-3=-1116/994, 3-4=-1071/1124, 4-23=-1023/1091, 5-23=-990/1051,
5-24=-982/1075, 6-24=-1028/1113, 6-7= 1061/1144, 7-8= 1104/1066, 8-9= 415/352
BOT CHORD 1-1 5=-815/929,14-15_ 960/929, 13-14=-960/929, 12-13=-1099/918, 12-25=-10991918,
25-26=-1099/918, 26-27=-1099/918, 11-27=-1099/918, 10-11=-843/942, 9-10= 843/942
WEBS 2-15=-475/507, 3-13=-460/139, 7-11=-496/128
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 9=678,
15=760.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 32 lb down and 211 lb up at 7-1-10,
120 lb down and 199 lb up at 8-0-0, 195 lb down and 379 lb up at 8-7-10, and 140 lb down and 214 lb up at 9-3-4, and 55 lb down and
225 lb up at 10-1-12 on top chord, and 55 lb up at 7-1-10, 47 lb down and 12 lb up at 8-0-0, 65 lb down and 107 lb up at 8-4-6, 68 lb
down and 3 lb up at 8-7-10, 65 lb down and 107 lb up at 8-10-14, and 56 lb down and 50 lb up at 9-3-4, and 3 lb down and 100 lb up at
10-1-10 on bottom chord. The desigrl/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4= 54, 4-5=-54, 5-6=-54, 6-9=-54, 16-19= 20
Continued on Daoe 2
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev- 10103,2015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricatlom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891090
74497
GRF
SPECIAL
1
1
Job Reference (optional)
Chambers (fuss, Fort Fierce, FL
49U s Aug10 LU1/INIIdR IIIUUJIIItlJr 1111:. IUtl A.9 GG IIH.—duII —U.G
I D:04141 DCB7QwRG?h?eJCrfKzY77F-w2tgFT01 xhAGI F62xEIYj iShZhSUdB65ftnm WXylJsx
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 4=70(F) 5=-112(F) 6=47(F) 12=-30(F) 13=22(F) 11=-3(F) 23— 63(F) 24= 84(F) 25=-105(F) 26=-65(F) 27=-53(F)
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314,
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
I
T11891091
74497
GRF1
COMMON
1
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL r.c4u s Aug io zui r Mi i ek mausmes, inc. i ue Aug zz i i A i A4 20 i r rage
I D:04141 DCB7QwRG?h?eJCrfKzY77F-w2tgFT01 xhAGI F62xElYjiSgvhSl d7K5ftnmW XylJsx
4-10-13 8-7-10 12-4.8 16-2-8
r 4-10-13 3-8-13 3-8-13 3-10-0
4x5 II
4x10 = 6x10 II 3x6 11 10x10 = 3x6 II 8x10 =
8-7-10
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL I
Plate Grip DOL
1.25
TC 0.35
Vert(LL)
0.10
7-8
>999
240
TCDL 7.0
Lumber DOL
1.25
BC 0.44
Vert(TL)
-0.16
7-8
>999
240
BCLL 0.0
Rep Stress Incr
NO
W B 0.39
Horz(TL)
0.03
5
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3 `Except'
3-7: 2x4 SP M 30
WEDGE
Left: 2x6 SP No.2, Right: 2x6 SP No.2
REACTIONS. (lb/size) 5=5126/0-6-14, 1=4493/0-7-10
Max Horz 1=-196(LC 6)
Max Uplift5=-2953(LC 8), 1=-271O(LC 8)
Scale = 1:30.8
ICP
0
PLATES GRIP
MT20 244/190
Weight: 209 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-6940/4222, 2-3=-6404/3841, 3-4=-6411/3846, 4-5=-7682/4456
BOT CHORD 1-8=-3662/6108, 8-16= 3662/6108, 16-17= 3662/6108, 7-17=-3662/6108,
7-18— 3896/6809, 18-19=-3896/6809, 6-19= 3896/6809, 6-20=-3896/6809,
5-20=-3896/6809
WEBS 2-8=-456/549, 2-7=-496/458, 3-7= 3196/5410, 4-7=-1315/733, 4-6=-609/1203
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=1501t; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpl=0.18; MW FRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.60
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except (it=lb) 5=2953.
1=2710.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2802 lb down and 1840 lb up at
6-1-8, 1411 lb down and 804 lb up at 8-0-12, 1404 lb down and 789 lb up at 10-0-12, and 1399 lb down and 786 lb up at 12-0-12, and
1403 lb down and 788 lb up at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others.
LOAD CASE(S) Standard
L;ontinuea a Da e z
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIP7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek®connectors. This design Is based only upon parameters shotim, and Is for an individual building component, not
�
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
buildng design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety InformaBon available from Truss Plate Institute. 218 N. Lee Street Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891091
74497
GRF1
COMMON
1
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
LOA[) CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=54, 3-5=-54, 1-9=-20
Concentrated Loads (lb)
Vert: 16=-2802(B)17=-1411(B)18=-1404(B)19=-1399(B)20= 1403(B)
7.640 s Aug 16 2017 MI I eK Industries, Inc. I ue Aug 22 11:41:54 2017 Vage 2
I D:04141 DCB7QwRG?h?eJCrfKzY77F-w2tgFT01 xhAGI F62xEIYjiSgvhSld7K5ftnmWXylJsx
© WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE 11411-7473 rev. f0/0311015 BEFORE USE.
Deslgn valld for use only with MITekO connectors. This design is based only upon parameters shown. and Is for an Individual building component, not
a truss system. Before use, the bulldIng designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with posslbie personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricatforL storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Job 4
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891092
74497
GRG
SPECIAL
1
e�
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:56 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-sQ?Qg9PHTIQ_XZGR2fnOo7YzoU4x5uaO6BGtaQylJsv
i 5-2-14 10-2-5 i 15-1-11 �16-6-1� 18-6-1 22-7-9 i 26-9-2 W-10-10 34-8-7 i 38-9-12
5-2-14 4-11.6 4-17-6 1-4-6 2-0.0 4-1-9 4-1-8 4-14-1-E
Scale = 1:70.7
6.00 12 3x4 II
3x4 11 5x8 3x4 11 3x8 = 3x6 = 4x5 = 45 =
4x5 = 3x4 II 3x6 = 4x10 = 7x8 7 8 31 9 10 11 32 12 33 13
25 24 23 228x143 4 MT18HS = 3x8 = 3x4 II 6x10 = 16 15 14
3x10 I 6x8 = 7x8 = 4x4 II
34 35 36 37 38 4x6 = 3x4 If 4x10 = 44 3x6 II
26-9-2
30-10-10
I9
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Well Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL)
-0.49 20-21 >938 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(TL)
-1.10 20-21 >420 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.98
HOrz(fL)
0.28 14 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
I Wind(LL)
0.83 20-21 >558 240
Weight: 502lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc puffins, except
BOT CHORD 2x4 SP M 30 `Except'
end verticals.
22-25: 2x6 SP No.2, 17-21: 2x4 SP M 31, 11-16: 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-8-6 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 25=2388/Mechanical, 14=2582/Mechanical
Max Horz25=59(LC 8)
Max Uplift25=-1722(LC 8), 14=-1880(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-25=-2291/1712, 1-26=-3675/2653, 26-27= 3675/2653, 2-27= 3675/2653,
2-28=-3675/2653, 3-28=-3675/2653, 3-29_ 3675/2653, 4-29=-3675/2653,
4-30=-10804/7844, 5-30=-10804/7844, 5-6= 11146/8090, 6-7=-9033/6612,
7-8=-8079/5940, 8-31— 8079/5940, 9-31=-8079/5940, 9-10_ 5312/3894,
10-11= 5312/3894, 11-32= 5244/3847, 12-32= 5244/3847, 12-33=-2354/1720,
13-33= 2354/1720, 13-14=-2520/1881
BOT CHORD 24-36— 4616/6316, 36-37=-4616/6316, 23-37=-4616/6316, 23-38=-903/1242,
22-38=-903/1242, 20-21=-8498/11581, 20-39= 6107/8287, 19-39= 6107/8287,
19-40=-5234/7140, 18-40=-5234/7140, 18-41=-5234/7140, 41-42=-5234/7140,
17-42=-523417140, 11-17=-252/258
WEBS 1-24=-3022/4194, 2-24=-404/471, 4-24=3081 /2221, 4-23=-717/647, 21-23=-3780/5166,
4-21=-3575/4881, 6-21=-817/642, 6-20=-4822/3499, 7-20=-2861/3931, 7-19=-258/231,
9-19— 885/1169, 9-18=-228/411, 9-17= 2246/1647, 15-17= 1635/2225, 12-17=-2767/3760,
12-15— 2830/2254, 13-15=-2438/3336
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=10011; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
(%tAjllir,q%�shfortruss to truss connections
0 WARNING - Vertry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101032015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
��
a Truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
IS always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fobricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 31Z Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
r
T11891092
74497
GRG
SPECIAL
1
2
Job Reference (optional)
Chambers I russ,- fort Pierce, I-L
7.640 s Aug 16 2017 MITek Industries, Inc. Tue Aug 22 11:41:56 2017 Page 2
I D:04141 DCB7QwRG?h?eJCrfKzY77F-sQ?QggPHTIQ_XZGR2fnOo7YzoU4x5uaO6BGtaQylJsv
NOTES-
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 25=1722, 14=1880.
11) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 87 lb down and 139 lb up at 1-5-5, 87 lb down and 139 lb up at 3-5-5, 87 lb
down and 139 lb up at 5-5-5, 87 lb down and 139 lb up at 7-5-5, 87 lb down and 139 lb up at 9-5-5, 91 lb down and 191 lb up at 32-6-13, and 91 lb down and 191 lb up at
34-6-13, and 91 lb down and 191 lb up at 36-6-13 on top chord, and 35 lb down and 8 lb up at 1-5-5, 35 lb down and 8 lb up at 3-5-5, 35 lb down and 8 lb up at 5-5-5, 35 lb
down and 8 lb up at 7-5-5, 35 lb down and 8 ib up at 9-5-5, 248 lb down and 205 lb up at 11-5-5, 366 lb down and 368 lb up at 18-6-1, 128 lb down and 124 lb up at 20-6-13,
128 lb down and 124 lb up at 22-6-13, 128 lb down and 124 lb up at 24-6-13, 128 lb down and 124 Ib up at 26-6-13, 128 lb down and 124 lb up at 28-6-13, 128 lb down and
124 lb up at 30-6-13, 68 Ito down and 3 lb up at 32-6-13, and 68 lb down and 3 lb up at 34-6-13, and 68 lb down and 3 lb up at 36-6-13 on bottom chord. The design/selection
of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-6=-54, 6-7=-54, 7-13=-54, 22-25=-20, 17-21— 20, 14-16— 20
Concentrated Loads (lb)
Vert: 24=-21(B) 2— 47(B) 20=-366(B) 19_ 128(B) 18=-128(B) 12=-91(B) 15=-40(B) 26=-47(B) 27=-47(B)28=-47(B) 29= 47(B) 32=-91(B) 33=-91(B) 34=-21(B) 35=-21(B)
36=-21(B) 37=-21(B) 38=-248(B) 39=-1 28(B) 40=-1 28(B) 41 =-128(B) 42=-128(B)43=-40(B) 44=-40(B)
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M?EKREFERANCE PAGE MIP7473 rev. 10/032015 BEFORE USE
"
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guldonce regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSE-89 and BCSI Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
4
T11891093
74497
GRH
MONO TRUSS
t
2
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug io zoi r MIT ek mausmes, inc. i ue Aug 22 11 A .57 2017 rage 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-KdZpuUQvEcYr9jrdcMIFKK4EhuQYgRzXLr?Q7sylJsu
4-2-15 8-1-8 i 11-5-11 1
' 4-2-15 3-10-9 3.4-3
3x4 11
" 5
4x4 = 3x4 11 6x8 = 6x8 =
4x8 11
8-1-8
Scale = 1:37.1
Plate Offsets (X,Y)--
f1:0-1-8 1-1-3j (1:0-3-8 Edgel (5:0-4-0 0-4-41
16:0-3-8 0-4-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
Vert(LL) 0.04
6-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(TL) -0.05
6-7 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.59
Horz(TL) 0.01
5 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 1601b FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puriins, except
BOT CHORD 2x6 SP No.2
end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
4-5: 2x6 SP No.2
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 5=3356/0-7-10, 1=1444/0-7-10
Max Horz 1=333(LC 8)
Max Uplift5=-2376(LC 8), 1=-889(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1782/1106, 2-3= 2156/1387
BOT CHORD 1-7=-1218/1521, 6-7=-1218/1521, 6-11=-1390/1905, 5-11— 1390/1905
WEBS 2-7=-470/345, 2-6=-555/435, 3-6=-2171/3103, 3-5=-3029/2215
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face In the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpl=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 5=2376,
1=889.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2562 lb down and 1900 lb up at
8-1-8, and 1405 lb down and 890 lb up at 10-0-12 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 1-5— 20
continued on a e 2
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MIrEKREFERANCE PAGEM1F7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 31 Z Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
`
T11891093
74497
GRH
MONO TRUSS
1
2
Job Reference (optional)
CSlambers Truss, - Fort Pierce, FL
LOA[fCASE(S) Standard
Concentrated Loads (Ib)
Vert: 6=-2562(F) 11=-1405(F)
f.64U S AUg 1E zui t MI I eK Inaustries, mc. 1 Ue AUg ZZ 11:41 A r ZU11 Yage L
ID:04141 DCB7QwRG?h?eJCrfKzY77F-KdZpuUQvEcYr9jrdcMIFKK4EhuQYgRzXLr?Q7sylJsu
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED. mfrEK REFERANCE PAGE MIh7473 rev. 10/03,2015 BEFORE USE
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
I-
T11891094
74497
GRK
HIP
2
1
Job Reference (optional)
Ch'ambers Truss, - Fort Pierce, FL 7.640 s Aug 16 2017 Mt rek Industries, Inc. Tue Aug 22 11:41:57 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-KdZpuUQvEcYr9jrdcMIFKK47VuPlgMdXLr?Q7sylJsu
1-3-13 4-B-5 8-0-0 13-3-0 18-4-4 23-7-4 26-10-15 30-3-1 31-7A
h-3-13 3.4.8 3-3-11 5-3-0 5-1-4 5-3-0 -3-11 3-0-B 1-3-13
Scale = 1:54.8
6.00 12
4x8 =
2x3 11 3x4 = 4x8 =
4 24 25 5 26 27 28 6 29 30 7
m
e
0
10 m
Tj
0
17 16 "' "- 15 -- -. -. 13 -- -- 12 11
3x4 = 6x8 = 3x4 = 3x10 = Sx6 wB = 3x5 = 3x4 = 6x8 = 3x4 =
1-3-13 31-7-4
1-0-D t1-0.0 13-3-0 18-4-4 23-7-4 i 30-3-7 3¢7r4 i
1-0-0 6-8-3 5-3.0 5-1-0 5-3-0 6•e•3 0.- 3
Offsets
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Lid
TCLL
I
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.17 13-15
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.65
Vert(TL)
-0.41 13-15
>857
240
BCLL
0.0
Rep Stress Incr
NO
W B 0.93
Horz(TL)
0.13 11
n/a
n/a
BCDL
10.0
Code FBC2014lfP12007
(Matrix-M)
Wind(LL)
0.28 13-15
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 17=2004/0-7-10, 11=2003/0-7-10
Max Harz 17=193(LC 7)
Max Upliftl7= 1448(LC 8), 11= 1390(LC 8)
PLATES GRIP
MT20 244/190
Weight: 173 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-4-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-7-3 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-309/190, 3-4= 3092/2244, 4-24=-3740/2757, 24-25=-3740/2757, 5-25=-3740/2757,
5-26=-3740/2757, 26-27=-3740/2757, 27-28— 3740/2757, 6-28=-3740/2757,
6-29=-3740/2762, 29-30=-3740/2762, 7-30=-3740/2762, 7-8= 3091/2249, 8-9=-312/216
BOT CHORD 16-17=-1722/2426, 16-31— 1933/2750, 31-32— 1933/2750, 15-32=-1933/2750,
15-33= 2578/3740, 14-33=-2578/3740, 14-34=-2578/3740, 13-34= 2578/3740,
13-35=-1876/2749,,35-36= 1876/2749, 12-36= 1876/2749, 11-12=-167312426
WEBS 2-17=-301/345, 3-17=-2711/1983, 3-16=-436/493, 4-16=0/328, 4-15— 958/1281,
5-15=-553/644, 6-13=-585/654, 7-13= 976/1303, 7-12=0/328, 8-12= 429/479,
8-11=-2707/1950, 9-11= 301/331
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb)
17=1448, 11=1390.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 195 lb down and 366 lb up at 8-0-0,
91 lb down and 175 lb up at 10-0-12, 91 lb down and 175 lb up at 12-0-12, 91 lb down and 175 lb up at 14-0-12, 91 lb down and 175 lb
up at 15-9-10, 91 lb down and 175 lb up at 17-6-8, 91 lb down and 175 lb up at 19-6-8, and 91 lb down and 175 lb up at 21-6-8, and
139 lb down and 333 lb up at 23-7-4 on top chord, and 235 lb down and 174 lb up at 8-0-0, 68 lb down and 3 lb up at 10-0-12, 68 lb
down and 3 lb up at 12-0-12, 68 lb down and 3 lb up at 14-0-12, 68 lb down and 3 lb up at 15-9-10, 68 lb down and 3 lb up at 17-6-8,
68 lb down and 3 lb up at 19-6-8, and 68 lb down and 3 lb up at 21-6-8, and 235 lb down and 174 lb up at 23-6-8 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
0 WARNING - Verify design parameters and READ NOTES ON THis AND INCLUDED M/TEK REFERANCE PAGE Mll-7473 rev. 10103/2015 BEFORE USE.
'
Design valid for use only wllh MITekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/1PI1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Mexandrla, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11691094
74497
GRK
HIP
2
1
Job Reference (optional)
unamt)ers !CUSS, ton V18MG, M
ID:04141 DCB7.QwRG?h?eJCrfKzY77F-pp7B5gRY?wgintOpA4pUtYdlFll_ZpthaVl_flylJst
0
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=125, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 4-7=-54, 7-10=-54, 18-21=-20
Concentrated Loads (lb)
Vert:4=-139(B) 7=-139(B) 14=-40(B) 16=-235(B) 12=-235(B) 24= 91(B) 25=-91 (B) 26=-91 (B) 27=-91(B) 28=-91(B) 29= 91(B)30= 91(B) 31=-40(B) 32=-40(B) 33=-40(B)
34=-40(B)35=-40(B) 36=-40(B)
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 11111-7473 rev. 1010312015 BEFORE USE
'
Design valid for use only with MlTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
i1NiTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage. delivery. erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avdiable from Truss Plate Institute. 218 N. Lee Street, Suite 312 Alexandria. VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891095
74497
GRK1
SPECIAL
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 201 t Mr l eK industries, inc. t ue Aug 22 11 R1:66 20i t rage 1
ID:04I41 DCB7QwRG?h?eJCrfKzY77F-pp7B5gRY?wgintQpA4pUtYdK?InMZoDhaVl_flylJst
1-3-13 8-6-7 15-9-10 22.36 2&t-7 37-3.15 , 33-5-15 P-:9-12,
• 1-3-13 7-2-10 7-3-3 6-5-121-3-13
45 =
6.o0 12
Scale = 1:63.0
18 'V 13 12 11
3x6 = 3x4 = 3x6 = 4x10 — 3x5 — 3x4 =
3X4 = 3x4 = 3X6 11
1-3-13 33.9-12
,1-0-0 11-0-7 20-6-12 , 28-1.7 31- 5 , 33-515 i 34-9-1a
1-0-0 9-8-10 9G-5 7.6-11 3-2-8 2-2-0 0- - 3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (IOC)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.48
Vert(LL)
-0.32 15-17
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.56
Vert(TL)
-0.60 15-17
>649
240
BCLL
0.0
Rep Stress Incr
NO
W B 0.97
Horz(TL)
0.07 11
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.23 13-15
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 18=1272/0-7-10, 11=1215/0-7-10
Max Horz 18=-379(LC 6)
Max Upliftl8— 831(LC 8), 11=-775(LC 8)
Max Grav 1 8=1 282(LC 13), 11=1215(LC 1)
PLATES GRIP
MT20 244/190
Weight: 186 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-10-15 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 3-18
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-508/103, 2-3=-673/388, 3-4=-1778/1168, 4-5— 1740/1161, 5-6=-1956/1323,
6-7=-3121/2046, 7-25=-2633/1665, 8-25— 2633/1665, 8-9=-1276/838, 9-10=-228/358
BOT CHORD 1 -18=-196/495,17-18=-867/1847, 16-17=-494/1272, 16-26=-494/1272, 26-27=-494/1272,
15-27=-494/1272, 14-15=-1011/1833, 13-14= 1011/1833, 13-28— 647/1073,
12-28=-647/1073, 11-12=-342/241, 10-11=-342/241
WEBS 2-18=-536/578, 3-18=-1287/782, 4-17=-395/398, 5-17=-320/714, 5-15=-586/1072,
6-15=-681/587, 6-13=-815/1183, 7-13=-1574/1108, 8-13=-1060/1820, 8-12= 444/256,
9-12=-949/1516, 9-11 =-1 190/812
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=l lfh Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1'O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 18=831,
11=775.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 27 lb down and 65 lb up at 30-9-0,
and 32 lb down and 109 lb up at 31-3-15 on top chord, and 16 lb up at 30-9-0, and 45 lb up at 31,-3-15 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5= 54, 5-7=-54, 7-8=-54, 8-10=-54, 19-22=-20
uommuea on Daae 2
Q WARNING. Verify desfgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/0312015 BEFORE USE,
Design valid for use only with MiTck® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual trussweb and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 southern Star
T11891095
74497
GRK1
SPECIAL
2
1
Job Reference (optional)
Chambers Truss,- Fort Pierce, FL
LOM CASES) Standard
Concentrated Loads (Ib)
Vert: 8=37(F) 12=32(F) 25=13(F) 28=7(F)
7.640 a Aug 16 2017 MI I eK Industries, Inc. ]us Aug 22 11:41:b6 ZU11 Page Z
ID:04141 DCB7QwRG?h?eJCrfKzY77F-pp7B5gRY?wgintOpA4pUtYdK?I nMZoDhaVl_flylJst
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MIfEKREFERANCE PAGE MII--7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891096
74497
GRL
SPECIAL
2
1
Job Reference (optional)
Chambers Truss, - Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:41:59 2017 Page i
ID:04141 DCB7QwRG?h?eJCrfKzY77F-H?hZJASAmDoZO1?OknLjQlAbOiFvlTPgo9UXBIyIJss
1-3-13 2-8-9 i 4-9.8 7-4-4 i 9-5-3 i 10-9-15 i 12-1-12
13� 13 r 1-4.12 2-D-15 2-0-11 2-0-15 T 1-4-12 1-3-13 '
Scale = 1:21.4
3.71 12 4x8 =
44 =
22 5 23
2x3 11 2x3 11
4-9-8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress incr NO
Code FBC2014/TPI2007
CS1.
TC 0.07
BC 0.03
WB 0.08
(Matrix-M)
DEFL. in
Vert(LL) 0.01
Vert(TL) 0.01
Horz(TL) -0.00
(loc) I/deft Ud
12 >999 240
12 >999 180
9 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 63lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 14=226/0-7-10, 9=226/0-7-10
Max Horz 14=87(LC 7)
Max Upliftl4=-365(LC 8), 9=-318(LC 9)
Max Grav 14=231(LC 17), 9=231(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-94/293, 3-21=-137/367, 4-21— 121/347, 4-22= 122/344, 5-22=
122/344,
5-23=-120/349, 6-23=-136/366, 6-7=-94/293
BOT CHORD 13-24= 300/73, 12-24= 300/73, 12-25=-391/123, 11-25= 391/123, 11-26—
266/74,
10-26=-266/74
WEBS 2-14=-174/276, 2-13— 266/109, 7-10— 272/109
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=365,
9=318.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 62 lb down and 83 lb up at 2-8-9,
33 lb down and 98 lb up at 4-0-0, 15 lb down and 58 lb up at 4-9-8, 0 lb down and 78 lb up at 6-0-14, 15 lb down and 58 lb up at 7-4-4,
and 33 lb down and 98 lb up at 8-1-12, and 62 lb down and 83 lb up at 9-5-3 on top chord, and 64 lb down and 63 lb up at 2-8-9, 23 lb
up at 4-0-0, 32 lb down and 39 lb up at 4-9-8, 14 lb up at 6-0-14, 32 lb down and 39 lb up at 7-4-4, and 23 lb up at 8-1-12, and 64 lb
down and 63 lb up at 9-5-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASES) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-5_ 54, 5-6=-54, 6-8=-54, 15-18=-20
uortunuea on 3a le r
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE MIP7473 rev. 10103/2015 BEFORE USE
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stabllhy and to prevent collapse with possible personal Injury and property darnage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSR-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314,
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891096
74497
GRL
SPECIAL
2
1
Job Reference (optional)
ruse, - ron rrerce, rL
7.640 s Aug 16 2017 MI I ek IndUstrles, Inc. rue Aug 22 11:41:59 2017 Page 2
ID:04141 DCB7QwRG?h?eJCrfKzY77F-H?hZJASAmDoZO1?OknLjQlAbOiFvlTPgo9UXBlylJss
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 3=83(F) 4=52(F) 5=52(F) 6=83(F) 13=33(F) 12=23(F) 11=23(F) 10=33(F) 21=24(F) 22=-O(F) 23=24(F) 24=1O(F) 25=1(F) 26=10(F)
Q WARNING - Verify design pammetem and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to,preveni buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and 1n1SS systems, seeANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Star
'
T11891097
74497
GRM
MONO TRUSS
1
2
Job Reference (optional)
Chambers Truss,' Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. I ue Aug 22 l l :4'2:UU L10I r Pagel
I D:04141 DC67QwRG?h?eJCrfKzY77F-ICExW WSoXXwQOAaCHVsyyzijX6Nj 1 oPz1 pE4jBylJsr
i 5-5-1 10-6-10 i 15-8-3
' S-5-1 5-1-9 5-1
R
0
3x4 11
6.00 Fl2
4x10 II 3x8 11 4x6 = 3x5 = 3x4 = 6x8 =
Scale = 1:68.1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.28
Vett(LL)
-0.08 10-12
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.95
Vert(TL)
-0.17 10-12
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
W B 0.61
Horz(TL)
0.04 8
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.11 10-12
>999
240
Weight: 345 lb FT = 20%-
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 `Except`
BOT CHORD
7-8: 2x6 SP No.2
WEBS
SLIDER Left 2x6 SP No.2 2-6-0
REACTIONS. (lb/size) 8=2018/0-7-10, 1=4245/0-7-10
Max Horz 1=618(LC 24)
Max Uplift8— 1534(LC 8), 1=-2547(LC 8)
Max Grav8=2594(LC 28), 1=4256(LC 28)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-3084/1816, 2-3=-5350/3136, 3-4— 3384/1859, 4-5=-1578l722, 5-6= 1487/739
BOT CHORD 1-19=-3294/4888, 19-20— 3294/4888, 12-20=-3294/4888, 12-21= 3294/4888,
11-21=-3294/4888, 11-22=-3294/4888, 10-22= 3294/4888, 10-23=-2046/3141,
23-24= 2046/3141, 24-25=-2046/3141, 9-25=-2046/3141, 9-26= 883/1445,
26-27=-883/1445, 27-28=-883/1445, 8-28=-883/1445
WEBS 3-12= 1176/1918, 3-10=-2106/1467, 4-10= 1522/2337, 4-9=-2542/1743, 6-9= 1475/2627,
6-8= 2699/1651
Structural wood sheathing directly applied or 6-0-0 oc puriins, except
end verticals.
Rigid ceiling directly applied or 8-5-11 oc bracing.
1 Row at midpt 7-8, 6-8
NOTES-
1) 2-ply truss to be connected together with I Od (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all piles, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=l6omph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=10011; eave=l ift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=1534,
1=2547.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1046 lb down and 664 lb up at
1-5-9, 1046 lb down and 664 lb up at 3-5-9, 1046 lb down and 664 lb up at 5-5-9, 424 lb down and 301 lb up at 7-5-9, 424 lb down and
301 Ito up at 9-5-9, 424 lb down and 301 lb up at 11-5-9, 424 lb down and 301 lb up at 13-5-9, 154 lb down and 40 lb up at 15-2-4, and
207 lb down and 81 lb up at 17-2-4, and 188 lb down and 78 lb up at 19-2-4 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
Continued on Daae 2
0 WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev 10103,2015 BEFORE USE.
Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI i Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
`
T11891097
74497
GRM
MONO TRUSS
1
2
Job Reference (optional)
'Chambers Iruss,- Fort Pierce, FL
r.oau smug i o zu i r wi i ui, inuusnius, ili, i ue Huy zz i —z.vu — i i r- ya z
i D:04141 DCB7QwRG?h?eJCrfKzY77F-ICExW WSoXXwQOAaCH VsyyzijX6Nj 1 oPz1 pE4jBylJsr
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-7=-54, 8-13=-20
Concentrated Loads (lb)
Vert: 12=-1046(F) 19=-1046(F) 20� 1046(F)21=-387(F) 22=-387(F) 23=-387(F) 24= 387(F) 25=-51(F) 26=-48(F)28=66(F)
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use. the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Te k`
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891098
74497
GRN
MONO TRUSS
1
2
Job Reference (optional)
Chambers Truss, ' Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:01 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-DOoJjsTQlr2HeK90rCNBVAFWCVlomHR7GTzeGdylJsq
5-11-9 , 10-5-11 ,
' 5-11-9 4-6-1
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC2014/TPI2007
3x4 11
5
3x10 11 3x10 11 6x8 =
10-5-11
CSI.
DEFL.
in (loc)
I/dell
Ud
TC 0.16
Vert(LL)
0.07 6-11
>999
240
BC 0.83
Vert(TL)
-0.11 6-11
>999
240
WB 0.43
Horz(TL)
0.01 5
n/a
n/a
(Matrix-M)
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x6 SP No.2
WEBS 2x4 SP No.3 *Except* BOT CHORD
4-5: 2x6 SP No.2
SLIDER Left 2x6 SP No.2 2-6-0
REACTIONS. (lb/size) 1=2864/0-7-10, 5=1926/0-7-10
Max Harz 1=303(LC 21)
Max Upliftl=-1693(LC 8), 5=-1327(LC 8)
Max Gravl=2864(LC 1), 5=2009(LC 25)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1906/1080, 2-3=-2236/1290
BOT CHORD 1-13=-1361/2017, 13-14— 1361/2017, 6-14=-1361/2017, 6-15=-1361/2017,
15-16= 1361/2017, 5-16=-1361/2017
WEBS 3-6=-1385/2270, 3-5=-2563/1732
Scale = 1:36.6
PLATES GRIP
MT20 244/190
Weight: 145 lb FT = 20!
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=1693,
5=1327.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1063 lb down and 674 lb up at
1-2-4, 1063 lb down and 674 lb up at 3-2-4, 1063 lb down and 674 lb up at 5-2-4, and 458 lb down and 304 lb up at 7-2-4, and 458 lb
down and 304 lb up at 9-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Continued on Daae 2
Q WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 14II-7473 rev, 101032015 BEFORE USE.
Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891098
74497
GRN
MONO TRUSS
1
2
Job Reference (optional)
"uss, - ron rierce, M t.b4U s Aug 16 ZUl / MI I eK Inaustries, Inc. I U8 AUg 22 11:42:Ul ZUl / rage 2
ID:04141 DCB7QwRG?h?eJCrfKzY77F-DOoJjsTQlr2HeK90rCNBVAFwCVlomHR7GTzeGdylJsq
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-4= 54, 5-7=-20
Concentrated Loads (Ib)
Vert: 11=-1063(B) 13=-1063(B) 14=-1063(B) 15=-422(B) 16=-422(B)
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE Mll-7473 rev, 10/03/2015 BEFORE USE.
'
Design valid for use only with Mlrek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Informatlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891099
74497
J1
MONO TRUSS
18
1
Job Reference (optional)
Chambers Truss, - Fort Pierce, FL /.64U S Aug 16 ZU1 t m I eK Industries, Inc. I ue Aug ZZ i i:42mz ZU i / rage i
ID:04141 DCB7QwRG?h?eJCrfl(zY77F-haMixCU238B8FUjbPvuQlOn6pvFVVpMGU7jBo4ylJsp
1-3-13 0-8-3
Scale = 1:9.7
2x3 11
i-0-0
1-0-0
2-0-0
1-0-0
1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc) I/dell Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.10
Vert(LL)
0.00
5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.16
Vert(TL)
0.00
5 >999 240
BCLL 0.0
Rep Stresslncr YES
WB 0.07
Horz(TL)
0.00
3 n/a n/a
BCDL 10.0
Code FBC2014TFPI2OO7
(Matrix-M)
Wind(LL)
-0.00
5 >999 240
Weight: 7lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=-11/Mechanical, 4=-29/Mechanical, 5=186/0-7-10
Max Horz5=58(LC 12)
Max Uplift3— 15(LC 3), 4=-29(LC 1), 5=-178(LC 12)
Max Grav3=12(LC 10), 4=31(LC 12), 5=186(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpl=0.18; MW FRS (directional) and C-C Exterlor(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Ot=lb)
5=178.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
© WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03,2016 BEFORE USE
'
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown. and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
'
Tf 1891100
74497
J3
MONO TRUSS
15
1
Job Reference (optional)
Cftambers Truss, ' Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:03 2017 Page 1
0:04141 DCB7QwRG?h?eJCrfKzY77F-gmw48YVggSJ?telnzdPfabKFgJcoEGtQjmSIKWylJso
1-3-13 2-8-3
Scale = 1:14.8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2014ITP12007
CSI:
TC 0.21
BC 0.09
WB 0.12
(Matrix-M)
DEFL. in
Vert(LL) -0.00
Vert(TL) -0.00
HOrz(TL) 0.00
Wind(LL) -0.00
(loc) I/dell Lid
4-5 >999 360
4-5 >999 240
3 n/a n/a
4-5 >999 240
PLATES GRIP
MT20 244/190
Weight: 13 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=54/Mechanical, 4=19/Mechanical, 5=212/0-7-10
Max Harz 5=114(LC 12)
Max Uplift3=-69(LC 12), 5=-163(LC 12)
Max Grav3=75(LC 17), 4=40(LC 3), 5=212(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 251/88
WEBS 2-5=-170/390
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100fh eave=l lft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
5=163.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING - Verify design parameters end READ NOTES ON THIS AND INCLUDED MfTEK REFERANCE PAGE M11--7473 rev, 10/012015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual bullding component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord membersonly. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricaliom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891101
74497
J3A
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, ' Fort Pierce, FL 7.640 S Aug 16 2017 MI I eK Inaustrles, mc. 1 Ue AUg ZZ 11 :4Z:08 2U1 / rage 1
I D:04141 DC67QwRG?h?eJCrfKzY77F-9mw48YVggSJ?te1 nzdPfabKG6Jcq EGHQjmSIK WylJso
13-13 i 3-3-3 t
• r 1-3-13 1-11-6
Scale = 1:13.0
1-0-D
1-0-0
3-3-3
2-3-3
1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.13
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.09
Vert(TL) -0.00
5 >999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.09
Horz(TL) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 11 lb FT = 20
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-3-3 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=35/Mechanical, 4=8/Mechanical, 5=188/0-7-10
Max Horz 5=92(LC 12)
Max Uplift3=-47(LC 12), 5=-156(LC 12)
Max Grav3=51(LC 17), 4=25(LC 3), 5=188(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5— 128/300
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except gt=lb)
5=156.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERANCE PAGE 11111-7473 rev. 10MV2015 BEFORE USE.
'
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to buckling of inclivklual truss web and/or chord members only. Additional temporaryand permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSII-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street- Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
'
T71891102
74497
J313
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, • Fort Pierce, FL
3-8.6
3-8-6
7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:04 2017 Page 1
1D:04141DCB7QwRG?h?eJCrfKzY77F-dzUSMuVIbmFisVotzWKwu7ptKQj.—zk ,yQClsyy..,.
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
I/defl
Ud
TCLL
I
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
0.01
4 7
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.42
Vert(TL)
0.02
4-7
>999
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(TL)
-0.01
1
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.02
4-7
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 1=131/0-6-14, 3=89/Mechanical, 4=42/Mechanical
Max Horz 1=105(LC 12)
Max Uplift1=-36(LC 12), 3=-106(LC 12), 4= 17(LC 12)
Max Gravl=135(LC 17), 3=116(LC 17), 4=56(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2121283
Scale = 1:16.8
PLATES GRIP
MT20 2441190
Weight: 20 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=l6omph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24fh B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except Qt=lb)
3=106.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verfly design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11--7473 rev. 1010=015 BEFORE USE.
'
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addillonal temporary and permanent bracing
WOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcatiort, storage, delivery. erection and bracing of trusses and Truss systems, seeANSI/7PI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute. 218 N. Lee Street Suite 312 Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20OD5 Southern Star
•
T11891103
74497
J4A
MONO TRUSS
3
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:04 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-dzUSMuVIbm RsVotzW Kwu7ptNgjwjziaZyQClsyylJsn
1-3-13 i 4-9-2 _
• 1-3-13 3-5-5
Scale = 1:16.7
N
cb
N
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2014/TPI2007
CSI.
TC 0.40
BC 0.18
WB 0.15
(Matrix-M)
DEFL. in
Vert(LL) -0.00
Vert(TL) -0.01
Horz(TL) -0.01
Wind(LL) 0.00
(loc) I/deft. Ud
4-5 >999 360
4-5 >999 240
3 n/a n/a
4-5 >999 240
PLATES GRIP
MT20 244/190
Weight: 16lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-9-2 oc puriins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=73/Mechanical, 4=28/Mechanical, 5=240/0-7-10
Max Horz5=137(LC 12)
Max Uplift3= 90(LC 12), 5=-175(LC 12)
Max Grav3=97(LC 17), 4=54(LC 3), 5=240(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-327/114
BOT CHORD 1-5= 98/272
WEBS 2-5=-223/506
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
5=175.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verily design parameters end READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE Mll--7473 rev. la'032015 BEFORE USE
'
Design valid for use only with MiTek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Te k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and Truss systems, seeANSVTPI I Quality Criteria, DSB-69 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312 Alexandda. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891104
74497
J4B
MONO TRUSS
1
1
Job Reference (optional)
Cliambers Truss, Fort Pierce, FL
3x10 II
4-0-0
7.640 s Aug io 2017 rvn i arc uwusums, P.— y«1[:"c:vv �v 1 aiiv,
I D:04141 DCB7QwRG?h?eJCrfKzY77F-aLcCnZXZ7Nhak61 Mc]zMCEyaS W UdReQsPkhPxrylJsl
LOADING (psf)
SPACING-
2-0-0
CS].
DEFL.
in
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.96
Vert(LL)
-0.01
4-9
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.66
Vert(TL)
-0.02
4-9
>999
240
BCLL
0.0
Rep Stress Incr
YES
W B 0.00
Horz(TL)
-0.03
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.04
4-9
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 1=155/0-7-10, 3=88/Mechanical, 4=42/Mechanlcal
Max Horz 1=113(LC 12)
Max Upliftl= 46(LC 12), 3=-111(LC 12), 4= 15(LC 12)
Max Grav1=161(LC 17), 3=117(LC 17), 4=58(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-130/297
Scale = 1:17.3
PLATES GRIP
MT20 244/190
Weight: 21 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100111; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Corner(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except Qt=lb)
3=111.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MI7EKREFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
�
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply,
20005 Southern Star
'
T11891105
74497
J5
MONO TRUSS
19
1
Job Reference (optional)
Chambers Truss! Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:07 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-2Y9b_vYBthpQMFcYCTUbkRVnuwumA2J?eOQyTHylJsk
1-3-13 14-8-3
1-0-0 6-0-0
1-0-0 5-0-0
Plate Offsets (x,Y)-- f5.0-3-0 0-0-41
LOADING (psf)
SPACING-
2-0-0
CST.
DEFL.
in
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
-0.02
4-5
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.41
Vert(TL)
-0.04
4-5
>999
240
BCLL
0.0
Rep Stress Incr
YES
W B 0.22
Horz(TL)
-0.01
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.02
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=1 01 /Mechanical, 4=41/Mechanical, 5=291/0-7-10
Max Horz5=173(LC 12)
Max Uplift3=-123(LC 12), 5— 198(LC 12)
Max Grav3=132(LC 17), 4=75(LC 3), 5=291(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-458/160
BOT CHORD 1-5=-122/337
WEBS 2-5=-325/725
Scale = 1:20.7
PLATES GRIP
MT20 244/190
Weight: 20 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=1001t; eave=lift Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=123,
5=198.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�
a Truss system. Before use, the building designer must verify The applicability of design parameters and property Incorporate this design into The overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Sfar
T11691106
74497
J5A
MONO TRUSS
3
1
Job Reference o tional
Chambers Truss, • Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:07 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-2Ygb_vYBthpQMFcYCTUbkRVpDwwIA2p?eOQyTHylJsk
1-3-13 5-0-0
• 1-3-13 3-8-3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
L/d
TCLL
20.0
Plate Grip DOL
1.25
TC 0.70
Vert(LL)
0.01
4-5
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.31
Vert(TL)
-0.01
4-5
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.25
Horz(TL)
-0.01
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.01
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=78/Mechanical, 4=31/Mechanical, 5=250/0-7-10
Max Harz 5=143(LC 12)
Max Uplift3=-97(LC 12), 5=-180(LC 12)
Max Grav3=104(LC 17), 4=58(LC 3), 5=250(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=522/122
BOT CHORD 1-5=-103/420
WEBS 2-5=241/832
Scale = 1:18.1
PLATES GRIP
MT20 244/190
Weight: 17 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
5=180.
6) "Semi -rigid pitchbreaks Including heels" Member and fixity model was used In the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE M11.7473 rev. 101032016 BEFORE USE.
'
Design valid for use only with MITek9 connectors, This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web anchor chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 2231A.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
`
T11891107
74497
JSC
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, ' Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:08 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-W kjzCFZpe_xHzPBkIA?q Hf11 uKDrvXz9t2AV?jylJsj
i 3-7-10 i 5-0-0 i
3-7-10 1-4-6
8
3x4 II
3x8 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.45
Vert(LL)
-0.01
8-11
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.49
Vert(TL)
-0.02
8-11
>999
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.13
Horz(TL)
-0.02
5
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.02
B-11
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 2-6-0
0
0
Scale= 1:19.9
PLATES GRIP
MT20 244/190
Weight: 27lb FT=20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-11-10 oc bracing.
REACTIONS. All bearings Mechanical except Qt=length) 1=Mechanical.
(lb) - Max Harz 1=144(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 4 except 5=-295(LC 17), 6=-368(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 4, 5 except 6=523(LC 17)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-205/269
BOT CHORD 6-7— 290/168
WEBS 3-6=-244/422
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; 8=150ft; L=100fh eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) 1, 4 except (jt=lb)
5=295, 6=368.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 101=015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Pty
20005 Southern Star
•
T11891108
74497
J7
MONO TRUSS
47
i
Job Reference (optional)
Chambers Truss, ' Fort Pierce, FL r.o4u s Hug io zui r mu ek inausmes, inc. rue Aug 22 i r:42:08 2017 rage 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-W kjzCFzpe_xHzPBkIA?q Hf 114KGOvTm9t2AV?jylJsj
1-3-13 8-0-0 _
• 1-N, 6-8-3
3xs =
3x10 II
LOADING (psi)
SPACING-
2-0-0
CSI.
DEFL.
In
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.50
Vert(LL)
-0.05
4-5
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.28
Vert(TL)
-0.13
4-5
>581
240
BCLL
0.0 '
Rep Stress Incr
YES
W B 0.33
Holz(TL)
-0.03
3
n/a
n/a
BCDL
10.0
Code FBC2014/rP12007
(Matrix-M)
Wind(LL)
0.05
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=145/Mechanical, 4=60/Mechanical, 5=376/0-7-10
Max Horz 5=232(LC 12)
Max Uplift3=-176(LC 12), 5=-237(LC 12)
Max Grav3=188(LC 17), 4=108(LC 3), 5=376(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 674/234
BOT CHORD 1-5=-151/422
WEBS 2-5=-524/1110
Scale = 1:26.4
PLATES GRIP
MT20 244/190
Weight: 26 lb FT = 20
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=176,
5=237.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10/03,2015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
.
T11891109
74497
JA3
MONO TRUSS
1
1
Job Reference (optional)
Ch'ambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:09 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-_wHLPbZRP138bZmxJuW3gsaDKkd4e?915iv3YAylJsi
3x8 111
3-0-0
3-0-0
3-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
I/defl
Ud
TCLL I
Plate Grip DOL
1.25
TC 0.40
Vert(LL)
0.00
7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.23
Vert(TL)
-0.01
4-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(TL)
-0.01
1
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.01
4-7
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
SLIDER Left 2x6 SP No.2 2-6-0
REACTIONS. (lb/size) 1=106/Mechanical, 3=74/Mechanical, 4=31/Mechanical
Max Horz 1=84(LC 12)
Max Upliftl= 27(LC 12), 3=-91(LC 12), 4=-10(LC 12)
Max Grav1=108(LC 17), 3=98(LC 17), 4=44(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 176/262
Scale = 1:14.9
PLATES GRIP
MT20 244/190
Weight: 16 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft; eave=l ift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGEMIN7473 rev. 10102,2015 BEFORE USE.
Design valid for use only with MITek9 connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891110
74497
JC5
SPECIAL
1
1
Job Reference (optional)
Chambers Trus&, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:09 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F=wHLPbZRP138bZmxJuW3gsaFXkbxez915iv3YAyIJsi
1-3-13 i 4-7-10 6-0-0
1-3-13 3.3-13 1-4-6
Scale = 1:20.7
9 onY i i
3x6 II
1-0-0
1-0-0
-0-1
-3-1
4-7-10
3-3-13
6-0-0
1-41
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.26
Vert(LL)
-0.00
8-9
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.37
Vert(TL)
-0.01
8-9
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
W B 0.13
Horz(TL)
-0.01
5
n/a
n/a
BCDL 10.0
Code FBC20141TP12007
(Matrix-M)
Wind(LL)
0.01
7
>999
240
Weight: 25lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings Mechanical except (jt=length) 9=0-7-10.
(Ib) - Max Harz 9=173(LC 12)
Max Uplift All uplift 100 lb or less at Joint(s) 4 except 5_ 290(LC 17), 6=-303(LC 12), 9=-171(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 4, 5 except 6=482(LC 17), 9=261(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-253/56
WEBS 3-6=-190/310, 2-9= 205/433
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=1001t; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 5=290
6=303, 9=171.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify desrga pammeters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10103,2016 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is To buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11691111
74497
JC7
SPECIAL
7
1
Job Reference (optional)
`Chambers Truss,' Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:10 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-S7rjcxa3AcB?DjL7tb11M47S98nbNQdSKMfc4cyiJsh
1-3-13 4-7-10 8-0-0
• 13-13 3-3-13 3-4.6
i
3X4 — 8 3x4 11
3x5 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.14
Vert(LL)
-0.02
6
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.92
Vert(TL)
-0.04
7
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.18
Horz(TL)
-0.04
'5
n/a
n/a
BCDL
10.0
Code FBC2014fTP12007
(Matrix-M)
Wind(LL)
0.04
6
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30 `Except'
3-7: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=89/Mechanical, 8=341/0-7-10, 5=148/Mechanical
Max Horz8=232(LC 12)
Max Uplift4=-100(LC 12), 8=-205(LC 12), 5= 104(LC 12)
Max GraV4=112(LC 17), 8=341(LC 1), 5=183(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 7-8=-313/212, 5-6=-557/377
WEBS 2-8= 253/436, 3-5=-406/600
Scale = 1:25.4
PLATES GRIP
MT20 244/190
Weight: 34 lb FT = 20
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 9-10-10 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=15011t; L=100ft eave=l ift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 4 except Qt=ib) 8=205
, 5=104.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev iaV"015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown. and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTe k'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage- delivery, erection and bracing of trusses and Truss systems, seeANSI/TPIi Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891112
74497
JE
MONO TRUSS
2
1
Job Reference o tional
CMrnbers Truss, • Fort Pierce, FL 7.640 s AUg 16 2017 MI I eK industries, Inc. I ue Aug 22 11:4'2n u zul t rage 1
I D:04141 DC67QwRG?h?eJCrfKzY77F-S7rjcxa3AcB?DjL7tb1 IM47Ne8rcNNdSKMfc4cylJsh
1-3-13 i 6-9-0
1-3-13 5-5-3
6-9-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.50
Vert(LL)
-0.03
4-5
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.66
Vert(TL)
-0.07
4-5
>857
240
BCLL
0.0 *
Rep Stress Incr
YES
WB 0.37
HOrz(TL)
-0.02
3
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.04
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=119/Mechanical, 4=48/Mechanical, 5=322/0-7-10
Max Horz 5=168(LC 12)
Max Uplift3=-135(LC 12), 5= 222(LC 12)
Max Grav3=148(LC 17), 4=87(LC 3), 5=322(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 674/150
BOT CHORD 1-5=-114/474
WEBS 2-5=-354/1244
Scale = 1:20.1
PLATES GRIP
MT20 244/190
Weight: 22 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=l ift Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except (jt=lb) 3=135,
5=222.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M167473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. &acing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional Temporary and permanent bracing
M iTe k*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criterla, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
`
T11891113
74497
JE3
MONO TRUSS
4
1
Job Reference (optional)
fhambers Truss, ' Fort Pierce, FL 7.640 s Aug 16 2017 MUek Industries, Inc. Tue Aug 22 11:42:11 2017 Page 1
1D:04141 DC67QwRG?h?eJCrfKzY77F-wJP5gHbhxvJsgtvJRIYXvHfeFXKc6uLbZ00Ac2ylJsg
1-3-13 1-9-7
Scale = 1:12.5
2x3 11 5
i
1-0-0
1-0-0
3-1-4
2-1-4
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.12
Vert(LL)
-0.00
5
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.10
Vert(TL)
-0.00
5
>999
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.08
Horz(TL)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight:11 lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=30/Mechanical, 4=5/Mechanical, 5=184/0-7-10
Max Horz 5=88(LC 12)
Max Uplift3_ 42(LC 12), 5=-155(LC 12)
Max Grav3=46(LC 17), 4=21(LC 3), 5=184(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-120/284
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-1-4 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=lift; Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
5=155.
6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11,111-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate institute. 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891114
74497
JF
MONO TRUSS
1
1
Job Reference (optional)
,chambers Truss,- Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:11 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-wJP5gHbhxvJsgtvJRIYXvHfUKXFx6oDbZ00Ac2yIJsg
1-3-13 7-8-13
• 1-3-13 6-5-0
Scale = 1:25.5
dxa � 5
3x10 II
1-0-0 0-3-1
6-5-0
Plate Offsets (X Y)--
f 1-0-1-4 Edge) f5.0-3-0 0-0-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL) -0.04
4-5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.40
Vert(TL) -0.11
4-5 >655 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.48
Horz(TL) -0.04
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.07
4-5 >999 240
Weight: 25lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-8-6 oc puriins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=140/Mechanical, 4=58/Mechanical, 5=364/0-7-10
Max Horz5=223(LC 12)
Max Up1ift3=-168(LC 12), 5=-232(LC 12)
Max Grav3=181(LC 17), 4=104(LC 3), 5=364(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 960/222
BOT CHORD 1-5— 146/614
WEBS 2-5=-495/1600
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.0psf; h=24fh B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joints) except Qt=lb) 3=168,
5=232.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED WEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891115
74497
JG
MONO TRUSS
1
1
Job Reference (optional)
6hambers Truss, • Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:12 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-OVzTl dcKiD RjSt U W_04m RVChNxearJNlog8j8UyIJsf
3-6-0 3-2-1
3xio I[ 2x3 11 6x8 =
LOADING (psf)
SPACING-
2-0-0
CSL
DEFL.
in
(loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.61
Vert(LL)
0.00
5 6
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.24
Vert(TL)
0.01
5 6
>999
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.23
Horz(TL)
-0.01
1
n/a
n/a
BCDL
10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.01
6-9
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 1=237/0-6-14, 4=65/Mechanical, 5=177/Mechanical
Max Horz 1=192(LC 12)
Max Upliftl=-79(LC 12), 4=-75(LC 12), 5=-139(LC 12)
Max Gravl=248(LC 17), 4=83(LC 17), 5=217(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-220/447
BOT CHORD 1-6=-595/244, 5-6=-595/244
WEBS 3-5=-312/762
Scale = 1:24.5
PLATES GRIP
MT20 244/190
Weight: 37 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-11-2 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24fh B=150ft; L=100ft; eave=liit; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=139.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI l Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
`
T11891116
74497
JK
MONO TRUSS
2
1
Job Reference (optional)
'Chambers Truss Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:42:12 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-OVzT 1 dcKiDRjS 1 U W_04mRVCoaxg2rLPlog8j8UyIJsf
1-3-13 i 3-5-13
1-3-13 2-2-0
Scale= 1:13.5
2x3 11 5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.15
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.08
Vert(fL) -0.00
4-5 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(TL) 0.00
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 12lb F1'=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-5-13 oc puffins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=41/Mechanical, 4=12/Mechanical, 5=194/0-7-10
Max Horz 5=99(LC 12)
Max Uplift3= 54(LC 12), 5=-157(LC 12)
Max Grav3=59(LC 17), 4=29(LC 3), 5=194(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when .shown.
WEBS 2-5=-139/324
NOTES-
1) Wind: ASCE 7-10; VUIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150I11; L=100ft; eave=liit; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Ot=lb)
5=157.
6) "Semi -rigid pltchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII--7473 rev. 10/03,2015 BEFORE USE.
Design valid for use only with MITekO connectors. ]his design Is based only upon parameters shown, and Is for an Individual building component. not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-69 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891117
74497
JL
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss,- Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:13 2017 Pagel
ID:04141 DCB7QwRG?h?eJCrfKzY77F-siXsFzcyTXZa4A3iYjb?_ilyRL09aoNuOKtGhxylJse
1-3-13 3-11-6
1-3-13 2-7-9
a:3 11 5
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.20
Vert(LL)
-0.00
4-5
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.09
Vert(TL)
-0.00
4-5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.11
Horz(TL)
0.00
3
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
-0.00
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=53/Mechanical, 4=19/Mechanical, 5=210/0-7-10
Max Horz5=98(LC 12)
Max Uplift3= 63(LC 12), 5=-169(LC 12)
Max Grav3=70(LC 17), 4=39(LC 3), 5=21 O(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
WEBS 2-5=-164/384
Scale = 1:13.4
PLATES GRIP
MT20 244/190
Weight: 13 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-11-6 or, purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100ft eave=11fh Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &
MW FRS for reactions shown; Lumber OOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
5=169.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED M17EK REFERANCE PAGE MII-7473 rev. 10/0311015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate This design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stabfiity and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabricaflon, storage, delivery, erection and bracing of Trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891118
74497
K
HIP
2
1
Job Reference (optional)
Ghambers Truss, . Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:42:14 2017 Page 1
I D:04141 DCB7QwFIG?h?eJCrfKzY77F-Lu5ESIdaEghRhKeu6R6EXwH5ilHJJ5J 1 F_dgDNyiJsd
1-3-13 5-10-9 10-0-0 15.9-10 21-7-4 25-8-11 30-37 31-7-4
1-313 4-6-12 4-1-7 5-9-10 5-9-10 4-1-7 4-6-12 1-313
4x8 =
21
2x3 11
4x8 =
6 22
Scale = 1:54.9
3x4 =
3x4 = 5x8 = 3x4 = 3x4 =
1.3-13
31-7-4
i i-D 10-0-0 15-9-10 21.7-4
30.3-7 30-7r4 i
1-0-0 8-8-3 5-9-10 5-9-10
8-8-3 0- 3
0-3.13
1-0-0
Plate Offsets (Y Y)--
f2:0-7-9 0-3-01 f4:0-5-4 0-2-0) j6:0-5-4,G-2-01
f8:0-7-9,0-3-01,f12:0-4-0,0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL) -0.10
10-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.42
Vert(TL) -0.26
10-11 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.71
Horz(TL) 0.06
10 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.10
12 >999 240
Weight: 172lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 5-8-2 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 6-8-15 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 14=116910-7-10, 10=1169/0-7-10
Max Harz 14= 240(LC 10)
Max Upliftl4= 765(LC 12), 10= 707(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 417/21, 2-3=-443/285, 3-21= 1515/1466, 4-21= 1412/1468, 4-5=-1567/1645,
5-6=-1567/1645, 6-22=-1412/1468, 7-22=-1515/1466, 7-8=-453/28518-9=-417/48
BOT CHORD 1-14=-89/336, 13-14=-1190/1455, 12-13=-965/1326, 11-12=-960/1312, 10-11=-1185/1361,
9-10=-89/336
WEBS 2-14=-286/555, 3-14=-1254/1311, 3-13=-163/274, 4-13=-99/289, 4-12=-345/420,
5-12=-359/467, 6-12= 345/420, 6-11=-99/289, 7-1 1=-1 65/274, 7-10=-1254/1311,
8-10= 286/555
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 10-0-0, Exterior(2) 10-0-0 to
21-7-4 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
tit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 14=765,
10=707.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M1rEKREFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
7
Design valid for use only with MITekB connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
'
T11891119
74497
K1
HIP
2
1
Job Reference (--I --- 1
• Chambers Truso, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:14 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-Lu5ESIdaEghRhKeu6R6EXwH3flJBJBb1 F_dgDNylJsd
�1-313 69-5 12-0-0 19-7-4 24-9-15 30-3-7
1.3-13 5-5-B 5-2-11 7-7-4 5-2-11 5-5-8 1-3-13
Scale = 1:55.2
4x8 =
4x6 =
15 14 13 11 10 9
3X4 — 4x4 = 3x4 = 3x6 = 3x8 = 4x4 = 3x6 II 3x4 =
3x6 11
1-3-13
31-7-4
1-0-0 6-9-5 12-0-0
19-7-4
24-9-15 303-7
3¢7r4 ,
1-0-0 5-5-8 5-2-11
7.7-4
5-2-it S.S.
0- • 3
0-3-13
1.0-0
Plate Offsets (X,Y)--
r4:0-5-4 0-2-0) r5:0-3-8 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.49
Vert(LL) -0.07
11-13 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.30
Vert(TL) -0.21
11-13 >999 240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.56
Horz(TL) 0.04
9 n/a n/a
BCDL 10.0
Code FBC20141TPI2007
(Matrix-M)
Wind(LL) 0.08
11 >999 240
Weight: 173 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-7-1
oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-9-6 oc bracing.
WEBS 2x4SPNo.3
WEBS
1 Row atmidpt 4-11
REACTIONS. (lb/size) 15=1169/0-7-10, 9=1169/0-7-10
Max Horz 15=-288(LC 10)
Max Upliftl5— 765(LC 12), 9=-707(LC 12)
Max Grav15=1173(LC 17), 9=1169(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 253/119, 2-3= 1652/1490, 3-22= 1421/1378, 4-22=-1354/1387, 4-5=-1222/1345,
5-23=-1329/1388, 6-23=-1422/1378, 6-7= 1641/1491, 7-8=-274/120
BOT CHORD 1-15=-192/264, 14-15=-213/479, 13-14=-1179/1604, 13-24=-855/1340, 12-24=-855/1340,
11-12= 855/1340, 10-11=-1149/1406, 9-1 0=-1 85/298, 8-9=-185/298
WEBS 2-15=-1086/1228, 2-14=-980/1157, 3-13=-324/389, 4-13=-174/388, 5-11=-190/355,
- 6-11 =-335/389, 7-10— 977/1156, 7-9=-1066/1227
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 12-0-0, Exterior(2) 12-0-0 to
19-7-4 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
tit between the bottom chord and any other members, with BCDL = 10.Opst.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 15=765,
9=707.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MITek6 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
NOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery• erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Star
T11891120
74497
K2
HIP
2
1
Job Reference (optional)
Chambers Truss, • Fort Pierce, FL 7.640 S Aug 16 2017 MI I sk industries, Inc. I ue Aug 22 11 A2:15 2017 rage 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-p4ecgeeC?BpIJU D4g8dT37q E69dx2bfB UeMNIpylJsc
7-1-5 14-0-0 17-7-4 24-5-15 29-6-8
• 7-1-5 6-10-11 3-7-4 6-10-11
4x8 =
4x6 =
Scale = 1:52.6
12 11 9 6 7
3x6 I1 3x4 = 3x6 = 3x8 = 4x4 = 3x6 11
3x4 =
6-9-8 71 5 14-M
17-7-4
24-5-15 29-6-8
6-9-8 0- - 3 6-10-11
3-7-4
6-10-11 5-0-9
Plate Offsets (X Y)--
13:0-5-4 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Vert(LL) -0.05
8-9 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(TL) -0.15
8-9 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.58
Horz(TL) 0.01
7 n/a n/a
BCDL 10.0
Code FBC2014ITP12007
(Matrix-M)
Wind(LL) -0.06
11-12 >999 240
Weight: 165lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 2-11
REACTIONS. (lb/size) 12=1444/0-7-10, 7=732/0-6-14
Max Horz 12= 313(LC 10)
Max Upliftl2= 1233(LC 12), 7= 387(LC 12)
Max Grav 12=1 444(LC 1), 7=776(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2— 1184/612, 2-16=-557/288, 3-16=-480/311, 3-4=-559/557, 4-17=567/514,
5-17= 677/501, 5-6=-1009/746, 6-7=-735/588
BOT CHORD 1-12=-465/1193, 11-12=-507/1152, 10-11=-110/491, 9-10=-110/491, 8-9=
580/854
WEBS 2-12=-1272/1735, 2-11=-1088/946, 3-11= 346/594, 3-9=-505/406, 5-9= 472/588,
6-8=-540/818
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extehor(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 14-0-0, Extehor(2) 14-0-0 to
17-7-4 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 1b uplift at joint(s) except (jt=lb)
12=1233, 7=387.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used In the analysis and design of this truss.
Q WARNING - VerW desfgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI17473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown. and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria. DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891121
74497
K3
COMMON
6
1
Job Reference (optional)
Chambers Truss, • Fort Pierce, FL 7.640 S AUg 16 2017 MI I eK industries, inc. I ue AUg'L'L i i AL:16 zui / Page!
ID:04141 DCB7QwRG?h?eJCrfKzY77F-HHC_t_fgmSx9xeoHDs8icLNOKYztnzEKil6xlGyIJsb
7-1-5 10-6-10 15-9-10 22-11-4 29-6-8
• 7-1-5 3-5-5 5-3-0 7-1-10 6-7-4
4x5 =
6.00 12
Scale = 1:54.3
11 '- -- 10 9 8
3X4 = 6x8 SX10 = 4x4 = 3x6 I
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2014/TP12007
CSI.
TC 0.55
BC 0.41
WB 0.87
(Matrix-M)
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in (loc) I/dell Ud
-0.09 10-11 >999 360
-0.19 10-11 >999 240
0.01 8 n/a rVa
-0.09 10-11 >999 240
PLATES GRIP
MT20 244/190
Weight: 158 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except .
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 6-10
REACTIONS. (lb/size) 11=1445/0-7-10, 8=730/0-6-14
Max Horz 11= 356(LC 10)
Max Upliftl 1 =-1 235(LC 12), 8=-385(LC 12)
Max Grav 11 =1 445(LC 1), 8=780(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-1 5=-1 237/558, 2-15— 1215/640, 2-3= 940/513, 3-16=-934/544, 4-16=-928/588,
4-5=-570/448, 5-17— 514/463, 6-17=-591/439, 6-18=-884/746, 7-18=-999/732,
7-8=-718/615
BOT CHORD 1 - 11 =-499/1249, 11-19=-116/465, 19-20= 116/465, 10-20— 116/465,
9-10=-535/819
WEBS 2-11= 367/610, 4-11 =-1 137/1317, 4-10=-495/461, 6-10=-587/673, 7-9=-413/705
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=1001h eave=l ift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interlor(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = I O.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
11=1235, 8=385.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03,2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
11''
MiTe R•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T71891122
74497
K4
SPECIAL
2
1
Job Reference (optional)
• Chambers Trussl Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:42:16 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-H HC_t_fgmSx9xeoH DsBicLNQ_YzCnxHKil6xIGylJsb
i 7-1-5 10�-10 15-9-10 22-11-4 i 28-1-7 31-3-15 33-9-12
7-1-5 3-5-5 5-3-0 7-1-10 5-2-3 3-2-8 ' 2-5-13 '
4x6 =
6.00 12
Scale = 1:61.3
6x8 = 3x6 = 3x8 = 3x4 = 2x3 11 3x4 = 3x8 II
3x5 =
3x6 =
33-9-12
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.44
Vert(LL) .
-0.11 15-17 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(TL)
-0.24 15-17 >999 240
BCLL 0.0
Rep Stress Incr
YES
WB 1.00
Horz(TL)
0.04 10 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.1112-13 >999 240
Weight: 185lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-9-10 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 6-15
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) '10=919/0-7-10, 17=1583/0-7-10
Max Harz 17— 368(LC 10)
Max Up11ftl0=-507(LC 12), 17=-1311(LC 12)
Max Grav 1 0=952(LC 18), 17=1583(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-27=-1198/561, 2-27= 1176/643, 2-3=-902/515, 3-28= 896/545, 4-28=-891/589,
4-5=-748/512, 5-6= 760/517, 6-29=-1445/1013, 7-29=-1526/1001, 7-8=-107ln92,
B-9=-1254/895
BOT CHORD 1-17=-502/1216, 17-30= 78/473, 16-30= 78/473, 15-16=-78/473, 14-15=-735/1301,
13-14=-735/1301, 12-13= 1330/2134, 11-12= 1327/2140, 10-11=-653/991
WEBS 2-17= 366/607, 4-17= 1300/1407, 4-15=-548/555, 5-15=-65/340, 6-15=-977/940,
6-13= 203/460, 7-13= 881/676, 7-11 =-1 2691758, 8-11= 372/670
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL_4.2psf; BCDL=3.Opsf; h=24ft B=15oft; L=100ft; eave=l ift; Cat.
11; Exp C; Enci., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Intedor(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13, Intedor(1) 28-1-7 to 31-3-15 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 10=507,
17=1311.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate This design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallon, storage, delivery, erection and bracing of Trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
�
T71891123
74497
K5
SPECIAL
4
7
Job Reference (optional)
• Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:42:17 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-ITmM4KfSX13OYoNTnZfxBYvcfyHm WQ2UxyrUgiylJsa
7-1-5 10-6-10 15-9-10 21-0-10 26-1-7 28-3-15 33-5-15 34.9-12,
7.1-5 35-5 5-3-0 53.0 5-0-13 3-2.8 41-0 134
4x4 =
6.00 12
Scale = 1:62.7
17 '� 15 -- 13 12 11
6x8 = 3x6 = 3x8 — 3x6 = 3x8 = 4x4 — 3x4 =
3x4 = 3x6 11
34-9-12
6-9-6 7 1 5 15-9-10 26-1-7 29.395 33-5-16 33 12
6-&8 0- - 3 8-8-5 10-3-13 3-2-e 4-2-0 0- - 3
1-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
In (loc)
I/dell
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL)
-0.21 13-15
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.50
Vert(TL)
-0.56 13-15
>565
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.84
Horz(TL)
0.03 11
n/a
n/a
BCDL
10.0
Code FBC2014ITP12007
(Matrix-M)
Wind(LL)
0.12 13-15
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
PLATES GRIP
MT20 244/190
Weight: 186 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-10-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row atmidpt 4-17
REACTIONS. (lb/size) 17=1579/0-7-10, 11=998/0-7-10
Max Harz 17=379(LC 11)
Max Uplift17= 1308(LC 12), 11= 554(LC 12)
Max Gravl7=1579(LC 1), 11=1045(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-24=-1189/569, 2-24=-1167/651, 2-3=-897/522, 3-25=-891/553, 4-25=-885/597,
4-5=-807/518, 5-6=-793/549, 6-26=-2136/1476, 7-26=-2166/1459, 7-8=-1833/1185,
8-9=-1356/917
BOT CHORD 1-17=-509/1208, 17-27— 93/508, 16-27=-93/508, 15-16=-93/508, 15-28= 451/1069,
28-29= 451/1069, 14-29=-451/1069, 13-14=-451/1069, 12-13=-647/1120
WEBS 2-17= 367/597, 4-17=-1314/1414, 4-15=-526/575, 5-15=142/435, 6-15=-788/829,
6-13= 782/1122, 7-13— 1150/892, 8-13=-425/890, 9-12=-657/1020, 9-11=-956/917
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=11ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13, Interior(1) 26-1-7 to 29-3-15 zone;. cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
17=1308, 11=554,
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE Mll-7473 rev. 10/0320f5 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the bdlding designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricafion, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891124
74497
KJ4
MONO TRUSS
4
1
Job Reference (optional)
chambers Truss, • Fort Pierce, FL 7.640 s Aug 16 2017 MlTek Industries, Inc. Tue Aug 22 11:42:18 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-DfKilgg413CtAyyfLHAAhmSsYMkBF4WdAcblM8ylJsZ
4-7-15
1-6-2 3-1-13
Scale = 1:14.7
5
2x3 11
1-1-10
3-6-5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.05
Vert(LL) -0.00
4-5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.04
Vert(TL) -0.00
4-5 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.06
Horz(TL) 0.00
3 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 15 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-7-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=12/Mechanical, 4=-0/Mechanical, 5=226/0-8-15
Max Harz 5=114(LC 8)
Max Upllft3=-43(LC 5), 4= 6(LC 7), 5=-189(LC 8)
Max Grav3=14(1-0 13), 4=8(LC 3), 5=226(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=15011; L=100ft; eave=lift Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
5=189.
6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 45 lb down and 113 lb up at 3-11-8
on top chord, and 51 lb up at 3-11-8 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 1-3=-54, 4-6=-20
Concentrated Loads (lb)
Vert: 9=68(F) 10=29(F)
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11--7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. this design Is based only upon parameters shown, and Is for an individual building component not
�
a truss system. Before use, the building designer must veilfy the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web aril/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Jab
Truss
Truss Type
Qty
Ply
20005 Southern star
•
T11891125
74497
KJ7
MONO TRUSS
6
1
Job Reference (optional)
chambers Truss, • Fort Pierce, FL
7.640 s Aug 16 2017 MiTek Industries, Inc. 1 ue Aug 22 11:42:18 2017 rage 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-DfKIIgg413CtAyyfLHAAhmSpeMitF1 EdAcbl M8ylJsZ
i 1-9-10 i 6-4-9 i 11-3-0 i
� 4-6-15 4-10-7
Scale = 1:23.7
7 4X4 = 3X4 =
2X3 11
1-4-4 0-5-6
4-6-15
4-10-7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
-0.02
5-6
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(TL)
-0.05
5-6
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.20
Horz(TL)
-0.01
4
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wlnd(LL)
0.01
6
>999
240
Weight: 52lb FT=20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=124/Mechanical, 7=352/0-10-13, 5=223/Mechanical
Max Horz7=232(LC 8)
Max Uplift4=-146(LC 8), 7=-298(LC 8), 5= 158(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-380/333, 11-12=-328/298, 3-12=-339/245
BOT CHORD 6-16=-338/34115-16=-338/341
WEBS 2-7=-350/194, 2-6=-263/427, 3-5=-381/379
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24fh B=150ft; L=100fh eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 4=146,
7=29815=158.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 97 lb up at 2-11-0,
50 lb down and 97 lb up at 2-11-0, 2 lb down and 110 lb up at 5-8-15, 2 lb down and 110 lb up at 5-8-15, and 25 lb down and 159 lb up
at 8-6-14, and 25 lb down and 159 lb up at 8-6-14 on top chord, and 50 lb up at 2-11-0, 50 lb up at 2-11-0, 22 lb up at 5-8-15, 22 lb up
at 5-8-15, and 19 lb down and 17 lb up at 8-6-14, and 19 lb down and 17 lb up at 8-6-14 on bottom chord. The design/selection of
such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4=-54, 5-8=-20
Concentrated Loads (lb)
Vert: 11=56(F=28, B=28) 12=44(F=22, B=22) 13=-49(F=-25, B=-25) 14=77(F=39, B=39) 15=18(F=9, B=9) 16— 26(F=-13,
B=-13)
0 WARNING. Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
•
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891126
74497
KJB
MONO TRUSS �
2
1
Job Reference (optional)
• Chambers Trussr Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:19 2017 Page 1
I13:04141 DC87QwRG?h?eJCrfKzY77F-hru7VOhj3NKjo5Xsv_iPDz??zm45_WhmPGKbuaylJsY
i 1-4-14 4-10-11 i 8-7-1_5
1-4-14 3-5-13 3-9-5
Scale = 1:25.2
2x3 11
1-0-11 1-4-i 4-10-11
1-0-11 -4- 3-5-13
V^
8-7-15
3-9-5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.14
Vert(LL) 0.00
6 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(TL) -0.01
6-7 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.06
Horz(TL) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 42 lb FT = 20
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=69/Mechanical, 7=295/0-8-5, 5=87/Mechanical
Max Horz7=232(LC 8)
Max Uplift4=-86(LC 8), 7=-203(LC 8), 5=-97(LC 8)
Max Grav4=78(LC 13), 7=295(LC 1), 5=92(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except Qt=lb)
7=203.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 36 lb down and 181 lb up at 5-4-0,
and 35 lb down and 191 lb up at 5-6-11 on top chord, and 49 lb up at 5-4-0, and 49lb up at 5-6-11 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Root Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 5-8= 20
Concentrated Loads (lb)
Vert: 11=131(F=65, B=66) 12=45(F=23, B=22)
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED mrrEK REFERANCE PAGE MlIL7473 rev. 1010212015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek•
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
—
T11891127
74497
KJC7
SPECIAL
7
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:19 2017 Page I
ID:04141 DCB7QwRG?h?eJCrfKzY77F-hru7VOhj3NKjo5Xsv_iPDz??amxi_PwmPGKbuaylJsY
i 1-9-10 4-1.6 6-5-3 r 11-3-0
1-9-10 2-3-12 2-3-12 4-9-14
Scale = 1:23.7
10 4x8 = 3x4 II
2x3 11
1-44 1-9-1q 4-1-6 6-5-3
11.M
1-44 0-51 2-3-12 2-3.12
4-9-14
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.16
Vert(LL) 0.13
6-7 >869 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.60
Vert(TL) -0.15
6-7 >720 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.49
Horz(TL) 0.02
6 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 56lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x4 SP M 30 -Except`
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
4-8: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 5=109/Mechanical, 10=428/0-10-13, 6=394/Mechanical
Max Harz 10=232(LC 8)
Max Uplift5=-117(LC 8), 10=-373(LC 8), 6=-340(LC 8)
Max Grav5=119(LC 13), 10=428(LC 1), 6=394(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-14=-364/310, 3-14= 346/291, 3-15=-880/746, 4-15=-8571745
BOT CHORD 4-7=-299/345, 7-18=-974/988, 6-18=-967/979
WEBS 2-10= 410/289, 2-9= 366/497, 3-9= 318/297, 7-9=-386/338, 3-7=-507/542,
4-6=-1017/1005
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=l lfh Cat. -
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 5=117,
10=373, 6=340.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 Ib down and 97 lb up at 2-11-0,
50 Ib down and 97 Ib up at 2-11-0, and 13 Ib down and 129 Ib up at 5-8-15, and 2 Ib down and 11 O ib up at 5-8-15 on top chord, and 50
lb up at 2-11-0, 50 lb up at 2-11-0, 3 lb down and 371b up at 5-8-15, 22 lb up at 5-8-15, and 122 lb down and 143 lb up at 8-6-14, and
155 lb down and 176 lb up at 8-6-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=-54, 8-11=-20, 6-7= 20
Concentrated Loads (lb)
Vert: 14=56(F=28, B=28) 15=24(F=2, B=22) 16=77(F=39, B=39) 17=6(F=-3, B=9) 18=-276(F=-155, B= 122)
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE M11--7473 rev. 101012015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891128
74497
KJE
MONO TRUSS
2
1
Job Reference (optional)
Ckambers Truss, . Fort Pierce, FL 7.640 s Aug 16 2017 MI fek industries, Inc. I ue Aug 22 11:42:20 2017 Page 1
ID:04141 DC87QwRG?h?eJCrfKzY77F-92SVjMiLggSaQF62ShDemBXB2AP4jyXwdw48R1ylJsX
3-5-13 _ 6-7-10
1-6-6 1-11-7 3-1-13
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.12
Vert(LL)
-0.01
4-5
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.07
Vert(TL)
-0.02
4-5
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.09
Horz(TL)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.01
4-5
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=86/Mechanical, 4=32/Mechanical, 5=262/0-9-1
Max Horz 5=161(LC 8)
Max Uplift3= 110(LC 8), 5=-212(LC 8)
Max Grav3=108(LC 13), 4=64(LC 3), 5=262(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-242/294
Scale = 1:19.5
PLATES GRIP
MT20 244/190
Weight: 21 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=110,
5=212.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 46 lb down and 106 lb up at 3-9-13
on top chord, and 53 lb up at 3-9-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Root Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-54, 4-6=-20
Concentrated Loads (lb)
Vert: 9=69(B) 10=30(B)
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MrFEKREFERANCE PAGE 111II-7473 rev. 10/039015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891129
74497
KJE5
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss,• Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:20 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-92SVjMiLggSaQF62ShDemBXAUAPfjyLwdw48R1 y1JsX
1-6-6 3-6-10 7-1-5
1-6-6 2-2-5 3-4-11
Scale = 1:20.5
2x3 11
, 1-1-13 ,1-6-6,
1-1-13
4-2-2
2-7-12
7-1-5
2-11-4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.15
Vert(LL) -0.02
4-5 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.10
Vert(TL) -0.04
4-5 >999 240
BCLL 0.0 '
Rep Stress Incr NO
WB 0.10
Horz(TL) -0.01
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.01
4-5 >999 240
Weight: 23 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=100/Mechanical, 4=38/Mechanical, 5=277/0-9-1
Max Harz 5=173(LC 8)
Max Uplift3=-124(LC 8), 5=-220(LC 8)
Max Grav3=125(LC 13), 4=74(LC 3), 5=277(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-273/333
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=124,
5=220.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 46 lb down and 106 lb up at 3-9-13
on top chord, and 53 lb up at 3-9-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 4-6=-20
Concentrated Loads (lb)
Vert: 9=69(8) 10=30(B)
WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
tabrlcatlom storage, dellvery, erection and bracing of trusses and truss systems, seeANSf/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Toss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
e
T11891130
74497
KJF
MONO TRUSS
1
1
Job Reference (optional)
.Chambers Truss_ Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11 A2:21 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-eEOtwijza_aR1 Pg EOPktJ04H?ZlpSPE3saphzTylJs W
1-4-14 2-7-4 3-8-10
Scale= 1:23.5
_... 5
3x5 i I
1-0-11 i
1-0-11
7-8-12
6-8-1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
([cc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL) 0.03
4-5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.11
Vert(TL) -0.04
4-5 >999 240
BCLL 0.0 "
Rep Stresslncr NO
WB 0.12
Horz(TL) -0.01
3 n/a n/a
BCDL 10.0
Code FBC2014ITP12007
(Matrix-M)
Weight: 25 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directiyapplied or6-0-0 cc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=68/Mechanical, 4=29/Mechanical, 5=288/0-8-5
Max Horz 5=207(LC 8)
Max Uplift3=-124(LC 8), 4=-3(LC 7), 5= 218(LC 8)
Max Grav3=68(LC 1), 4=50(LC 3), 5=288(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-278/88
WEBS 2-5=-252/411
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100fh eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb) 3=124
, 5=216.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 36 lb down and 181 lb Lip at 5-4-0,
and 35 lb down and 191 lb up at 5-6-11 on top chord, and 49 lb up at 5-4-0, and 49 lb up at 5-6-11 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 4-6=-20
Concentrated Loads (lb)
Vert: 9=131(F=66, B=65) 10=45(F=22, B=23)
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M1TEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with M1Tek0 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, The building designer must verify The applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrlcatlom storage, delivery, erection and bracing of trusses and muss systems, seeANSI/1PI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11691131
74497
KJG
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, • Fort Pierce, FL 7.640 s Aug 16 2017 MI I eK Industries, Inc. I ue Aug 22 11:42:21 201 / rage 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-eEOtwijza_aR1 Pg EOPktJO4GZZkiSQ83saphzTylJs W
i 33-7 _ _ 6-6-14
3-3-7 3-3-7
Scale = 1:23.6
3X10 11
Plate Offsets (X,Y)--
f 1 :0-3-0 0-3-11 1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.12
4-9 >634 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.18
Vert(TL) -0.08
4-9 >923 240
BCLL 0.0 '
Rep Stress Incr NO
W B 0.00
Hor7.(TL) -0.06
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 28lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
SLIDER Left 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 1=205/0-7-8, 3=91/Mechanical, 4=54/Mechanical
Max Harz 1=175(LC 8)
Max Uplifts — 99(LC 8), 3=-155(LC 8), 4= 49(LC 8)
Max Gravl =205(LC 1), 3=91(LC 1), 4=58(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASIDE 7-10; VUIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100ft eave=s lit; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except Qt=lb)
3=155.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 195 lb up at 4-2-2,
and 22 lb down and 204 lb up at 4-4-14 on top chord, and 66 lb up at 4-2-2, and 67 lb up at 4-4-14 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 4-5=-20
Concentrated Loads (lb)
Vert: 11=105(F=49, B=56) 12=21(F=9, B=12)
Q WARNING - Vedfy design parameters and READ NOTES ON THIS AND I= uDED mrrEK REFERANCE PAGE Mll-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MfekO connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
aty
Ply
20005 Southern Star
+
T11891132
74497
KJK
MONO TRUSS
2
1
Job Reference (optional)
Ghambers Truss, o Fort Pierce, FL
7.640 s Aug 16 2017 Mi rek Industries, Inc. Tue Aug 22 11:42:21 2017 Page 1
I D:04141 DC87QwRG?h?eJCrfKzY77F-eEOtwijza_aR 1 PgEOPktJO4LIZILSQi3saphzTylJs W
i 1-9-10 4-10-6 _
1-9-10 3-0-12
2x3 11 5
Scale = 1:13.3
1-4-4
1-4-4
4-10-6
3-6
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.08
Vert(LL)
-0.00
4-5
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.07
Vert(TL)
0.01
4-5
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.03
Horz(TL)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
-0.00
4-5
>999
240
Weight: 16lb FT=20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=40/Mechanical, 4=-6/Mechanical, 5=183/0-10-13
Max Harz 5=99(LC 8)
Max Uplift3=-38(LC 8), 4= 17(LC 16), 5= 195(LC 8)
Max Grav3=40(LC 1), 4=18(LC 3), 5=183(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-10-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
5=195.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 97 lb up at 2-11-0,
and 50 lb down and 97lb up at 2-11-0 on top chord, and 50 lb up at 2-11-0, and 50 lb up at 2-11-0 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
8) Ih the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-3=-54, 4-6=-20
Concentrated Loads (lb)
Vert: 9=56(F=28, B=28) 10=77(F=39,,13=39)
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate institute, 218 N. Lee Street, Suite 312. Alexandra VA 2231A.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891133
74497
KJL
MONO TRUSS
4
1
Job Reference (optional)
,Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:22 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrf KzY77F-6QZF82jbL1ilfZFRa6F6rccXmz6CBtmD5EZFVvyIJsV
1-6-2 3-1-13
1-6-2 1-7-11
2x3 11 5
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.04
TCDL 7.0
Lumber DOL 1.25
BC 0.03
BCLL 0.0
Rep Stress Incr NO
WB 0.04
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 3=20/Mechanical, 4=-3/Mechanical, 5=205/0-8-15
Max Horz 5=76(LC 8)
Max Uplift3— 28(LC 8), 4= 3(LC 1), 5= 187(LC 8)
Max Grav3=36(LC 13), 4=16(LC 10), 5=205(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale= 1:11.4
DEFL. in (loc) I/defl Ud PLATES GRIP
Vert(LL) -0.00 5 >999 240 MT20 244/190
Vert(TL) 0.00 5 >999 240
Horz(TL) -0.00 3 n/a n/a
Weight: 11 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-1-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=1501t; L=100ft; eave=lift; Cat.
It; Exp C; Encl., GCpl=0.18; MW FRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
5=187.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
russ
Truss Type
Qty
Ply
z000s Southern Star
T11691134
74497
L
SPECIAL
2
1
Job Reference (optional)
. chambers I rues, Fort Fierce, FL
i.bgV s Aug 1 b CV 1 i MI I SK Inouslrles, Inc. I ue Aug LL I I :44:ez ev 1 i rage I
ID:04141 DCB7QwRG?h?eJCrfKzY77F-6QZF82jbLlilfZFRa6F6rccTjz4yBrRD5EZFVvylJsV
6-2-5
6-1-7
6-0-14
1-3-13 5-11.7 6-0 10-9.15 1 12-1-12
1-3-13 4-7.10 = 4-7-10 1-3-13
0-0-9
0.0-9
0-0-14
3
A 2x3
3x10 II 3xio II
s•2-5
1-0-0 -3-1 5-11-7 6- 4 169-15 11.1-1 12-1-12
1-0-0 -3-1 4-7-10 1 4-7-10 0-3-1 1-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.30
TCDL 7.0
Lumber DOL 1.25
BC 0.18
BCLL 0.0
Rep Stress Incr YES
WB 0.19
BCDL 10.0
Code FBC2014/fP12007
(Matrix-M)
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. Qb/size) 8=449/0-7-10, 6=449/0-7-10
Max Horz8=-145(LC 10)
Max Uplift8=-532(LC 12), 6= 473(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-262/596, 2-3= 393/896, 3-4=-393/896, 4-5=-262/596
BOT CHORD 1-8=-604/294, 7-8=-604/294, 6-7=-604/294, 5-6=-604/294
WEBS 3-7=-427/174, 2-8=-399/633, 4-6=-399/633
Scale = 1:23.2
IT
DEFL. in (loc) I/defl Ud PLATES GRIP
Vert(LL) 0.04 7-8 >999 240 MT20 244/190
Vert(TL) -0.03 7-8 >999 240
Horz(TL) -0.01 6 n/a n/a
Weight: 44 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 8-11-9 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100fh eave=f lit; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right
exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=532,
6=473.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and Truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Mexandrla, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
a
T11891135
74497
L1
COMMON
4
1
Job Reference (optional)
.Chambers Truss,, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:23 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-ad7eLNkD6bg9HjgdBqmLOp9ckNKfwHTMJ ulol MyIJsU
3-8-9 6-0-14 10-9-15 _ _r 12-1-12
3-8-9 2.4.5 4-9-1 1-3-13
4x4 =
" — 8 2x3 II
2x3 11
Scale = 1:23.0
Im 0
LOADING (psi)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stresslncr YES
Code FBC2014ITP12007
CSI.
TC 0.41
BC 0.47
WB 0.20
(Matrix-M)
DEFL. in
Vert(LL) 0.11
Vert(TL) -0.07
Horz(TL) -0.00
(loc) I/dell Ud
6-7 >782 240
6-7 >999 240
6 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 46lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 8=562/0-7-10, 6=336/0-7-10
Max HorzS= 146(LC 10)
Max Uplift8— 666(LC 12), 6=-339(LC 12)
Max Grav8=562(LC 1), 6=347(LC 22)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-100/273
WEBS 2-8=-304/680, 4-6=-365/461
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft eave=l ift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; porch left and right
exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=666,
6=339,
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MrFEK REFERANCE PAGE Mll-7473 rev. 101032015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, The building designer must verity the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891136
74497
M
COMMON
1
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:24 2017 Page 1
I D:04141 DCB70wRG?h?eJCrfKzY77F-2ph0YjlrtvyOutPphXHawl ikyngMfaf W YY2MaoyIJsT
1.3-13 8-6-7 15-9-10 23-0-13 30.1-12
1.3-13 7-2-10 7-3-3 733 7-0-15
4x6 =
6.00 F12
Scale = 1:54.5
11 - 7
3x4 = 3x6 = 3x4 = 6x8 =
3x4 =
13-13
i 1-0-0 11-0-7 i 20-6-13 _ _ _�30-1-12
1-0-0 9-8-10 9-" 9-6-16
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.63
Vert(LL)
0.32
8-10
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.50
Vert(TL)
-0.50
8-10
>694
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.85
Horz(TL)
0.06
7
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL)
0.10
8-10
>999
240
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
WEBS
REACTIONS. ()b/size) 11=1159/0-7-10, 7=1061/0-7-10
Max Horz 11= 362(LC 10)
Max Upliftl 1 =-759(LC 12), 7=-641(LC 12)
Max Gravl l=1187(LC 17), 7=1114(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=523/165, 2-15=-685/604, 3-15=-558/618, 3-16= 1560/1417, 4-16=-1479/1442,
4-17=-1460/1470, 5-17=-1542/1445, 5-18=-293/423, 6-18=-371/408, 6-7=-331/422
BOT CHORD 1-11=-328/507, 10-11=-1165/1678, 10-19= 605/1087, 9-19=-605/1087, 9-20=-605/1087,
8-20= 605/1087, 7-8— 1139/1387
WEBS 2-11=-548/951, 3-11=-1074/1019, 3-10=-412/580, 4-10— 508/736, 4-8=-48B/705,
5-8=-376/564, 5-7=-1340/1143
PLATES GRIP
MT20 244/190
Weight: 161 lb FT = 20
Structural wood sheathing directly applied or 5-6-1 oc purlins, except
end verticals.
Rigid ceiling directly applied or 6-9-11 oc bracing.
1 Row at midpt 3-11, 5-7
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Intedor(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 11=759,
7=641.
6) "Seml-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�'
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stablllfy and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
tabricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218, N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
•
T11891137
74497
M1
COMMON
7
1
Job Reference (optional)
.Chambers Truss.. Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:24 2017 Page 1
I13:04141 DCB7QwRG?h?eJCrfKzY77F-2phOYjlrtvyOutPphXHawlilQngRfaaWYY2MaoylJsT
1-3-13 8-6-7 15-9-10 23-0-13 29-9-15 31-7-4
1-3-13 7-2-10 7-" 7-3-3 6-9-2 1-9-5
4x6 =
6.00 F12
Scale = 1:55.3
12 8
3x4 = 3x4 = US = 3x4 = 6x8 = 3x4 =
1-3-13 31-7-4
i 1-0-01il 246-13 , 29-9-15 _ 30r1�1�
9-e•to 9-6-6 9-3-2 P �3 1-5-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.54
Vert(LL)
0.31
9-11
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.49
Vert(TL)
-0.51
9-11
>675
240
BCLL 0.0
Rep Stress Incr
YES
W B 0.85
Horz(TL)
0.06
8
n/a
n/a
BCDL 10.0
Code FBC2014/T-P12007
(Matrix-M)
Wind(LL)
0.10
9-11
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
PLATES GRIP
MT20 244/190
Weight: 166 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-6-7 oc puriins.
BOT CHORD Rigid ceiling directly applied or 7-1-4 oc bracing.
WEBS 1 Row atmidpt 3-12, 5-8
REACTIONS. (lb/size) 12=1152/0-7-10, 8=1187/0-7-10
Max Harz 12=379(LC 11)
Max Upliftl2= 754(LC 12), 8= 718(LC 12)
Max Grav 12=1181(LC 17), 8=1200(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-517/167, 2-19— 683/606, 3-19= 556/619, 3-20=-1549/1386, 4-20=-1468/1411,
4-21=-1427/1371, 5-21=-1508/1346, 5-22=-366/382, 6-22=-459/369, 6-7=-327/80
BOT CHORD 1-12= 329/505, 11-12=-1070/1681, 11-23=-508/1088, 10-23— 508/1088, 10-24=-508/1088,
9-24— 508/1088, 8-9=-1013/1330, 7-8= 110/307
WEBS 2-12= 550/951, 3-12=-1061/972, 3-11= 413/584, 4-11=-512/739, 4-9— 454/674,
5-9= 353/527, 5-8=-1225/1148, 6-8=-432/725
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=1501t; L=10011t; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 12=754,
8=718.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312- Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891138
74497
M2
COMMON
3
1
Job Reference (optional)
Chambers Truss, , Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. I ue Aug 22 11:42:25 2017 Nage 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-W?FOm3mTeD4tW0_?FFopTEEw1B?HO1?fnCnv6EylJsS
1-3-13 6-6-7 15-9-10 23-0-13 30-1-12
1-3-13 7-2-10 7-3-3 T" 7-0-15
4x6 =
6.00 12
Scale = 1:54.5
7
I6
-
3x4 = 4x6 = 3x4 = 4x12 II
3x4 =
1-3-13
1-0-0 11-0-7 20-6-12 30-1.12
1.0, 1 9-8-10 9-6-5 9-7-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
L/d
TOLL 20-0
Plate Grip DOL
1.25
TO 0.57
Vert(LL)
-0.34
8-10
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.52
Vert(TL)
-0.59
8-10
>586
240
BCLL 0.0 '
Rep Stress (ncr
YES
WB 0.84
Horz(TL)
0.11
7
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.16
8-10
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 7=1066/Mechanical, 11=1165/0-7-10
Max Harz 11= 364(LC 10)
Max Upl(ft7=-644(LC 12), 11=-762(LC 12)
Max Grav7=1120(LC 18), 11=1.192(LC 17)
PLATES GRIP
MT20 244/190
Weight: 156 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-8-13 oc bracing.
WEBS 1 Row atmidpt 3-11
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 504/141, 2-19=-652/562, 3-19= 535/596, 3-20= 1569/1422, 4-20=-1489/1447,
4-21=-1447/1456, 5-21— 1522/1438, 5-22=-1565/1471, 6-22=-1653/1451, 6-7=-293/207
BOT CHORD 1 -11 =-308/485, 10-11=-1164/1685, 10-23=-608/1095, 9-23=-608/1095, 9-24=-608/1095,
8-24=-608/1095, 7-8= 1121 /1381
WEBS 2-11= 554/955, 3-11 =-1 107/1031, 3-10= 404/575, 4-10=-505/742, 4-8=-458/671,
5-8=-382/557
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 01=1b) 7=644,
11=762.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED 611TEK REFERANCE PAGE M11--7473 rev. 10/0302015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute- 218 N. Lee Street Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891139
74497
M3
COMMON
4
1
Job Reference (optional)
Chambers Truss, . FortPierce, FL t.ti4u s Aug 16 Zul r m I eK inauslrie5, Inc. 1 ue Aug 22 11 A2:26 26 i r rage i
ID:04141 DCB7QwRG?h?eJCrfKzY77F-_CpmzPm6PWCk8AZCpyK2OSn4aaL17YQoOrXSehyIJsR
1-3-1338-6-7 15-9-10 23-2-5 30-1-12
1-.13 7-2-10 7-3-3 7-4-11 6-11-7
6.00 F12
a
0
4x6 =
Scale = 1:54.5
7
I7
3x4 = 3x6 =
3x4 = 3x6 II 3x10 II
3x4 =
1-3 13
1-0-0 11-0.7 20.6-12
23-2-5 30-1-12
1-0-0 9-8-10 9.6-5
2-7-9 6-11-7
0-3-13
Plate Offsets (),Y)—
(1:0-0-4 Edge1 (2:0-7-9 0-3-01 (3-0-4-0 Edge) (5:0-4-0 0-3-01 (7:0-7-12 0-0-61
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL) -0.25
9-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.53
Vert(TL) -0.44
9-11 >594 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.64
Horz(TL) -0.03
8 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Wind(LL) 0.35
9-11 >742 240
Weight: 162lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 4-9-14 oc bracing.
WEBS 2x4 SP No.3 WEBS
1 Row at midpt 3-12, 4-11, 4-9
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 12=953/0-7-10, 8=881/0-7-10, 7=397/Mechanical
Max Horz 12= 364(LC 10)
Max Upliftl2=-1114(LC 12), 8=-943(LC 12), 7=-281(LC 12)
Max Grav 1 2=953(LC 1), 8=881(LC 1), 7=485(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-467/97912-20=-580/1266, 3-20=-425/1279, 3-21 =-1 069/2186, 4-21 =-973/221 1,
4-22= 564/1383, 5-22=-644/1359, 5-23=-405/589, 6-23=-465/576, 6-7=-287/16
BOT CHORD 1-12=-923/446, 11-12=-1848/1037, 11-24=-815/584, 10-24=-815/584, 10-25=-815/584,
9-25=-815/584, 8-9=-383/388, 7-8=-362/382
WEBS 2-12=-654/611, 3-12=-710/1108, 3-11=-452/579, 4-11=-1428/590, 4-9= 275/280,
5-9= 872/474, 5-8= 835/1722
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=15oft; L=1001t; eave=lift Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
tit between the bottom chord and any other members, with BCDL = I O.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
12=1114, 8=943, 7=281.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERA NCE PAGE 11411-7473 rev, 1010312015 BEFORE USE
"
Design valid for use only with MITek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k°
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, socANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
2aoo5 Southern Star
T11891140
74497
M4
MONO HIP -
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:27 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-SON8BInkAgKbIK8ONfrlYfKFb_lvs_FyEVGOA7ylJsQ
1-313 9-4-5 16-1.8 23-2-5 30-1-12
1-3-73 8_" 6-9-3 7-0-13 6-11-7
4x8 =
2x3 11
6.00 12 5 18 6 19
3x4 =
13 12 10 "" 9 " 8
3x4 = 4X4 = 3X6 = 3x4 = 6X8 = 3X4 11
Scale = 1:59.2
3x6 I I
1-3-13
1-0-0 9d-5 i6-1-B
21-12
1-0-0 B-0-B 6-9-3
7 -0-0-13 13
6-6-11-7
2:3-13
Plate Offsets %Y)--
11:0-0-8 Edgel f3:0-3-0 Edgel (5:0-5-12 0-2-01'
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.61
Vert(LL) 0.22
12-13 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.32
Vert(TL) -0.17
12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
W B 0.66
Horz(TL) -0.03
8 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 190lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly
applied or 6-0-0 oc puffins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied
or 5-0-10 oc bracing.
OTHERS 2x4 SP No.3
WEBS
1 Row at midpt 7-8, 4-10, 5-10, 5-9, 6-9, 7-9
REACTIONS. (lb/size) 8= 20/Mechanical, 13=825/0-7-10, 9=1415/0-7-10
Max Horz 13=478(LC 12)
Max Uplift8= 20(LC 1), 13=-905(LC 12), 9= 1547(LC 12)
Max Grav8=167(LC 18), 13=825(LC 1), 9=1415(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-346/694, 2-17=-987/1614, 3-17=-891/1640, 3-4=-793/1641, 4-5=-467/791,
5-18=-317/180, 6-18=-317/180, 6-19= 317/180, 7-19=-317/180
BOT CHORD 1-13=-747/415, 12-13= 1395/483, 11-12=-1926/797, 10-11=-1926l797, 10-20=-843/342,
9-20— 843/342
WEBS 2-13=-875/1100, 2-12=-533/383, 4-12=-516/281, 4-10=-561/1339, 5-1
0=-1 276/487,
5-9= 794/1766, 6-9— 446/589, 7-9= 292/499
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=10011; eave=l lft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-4-5, Interior(1) 9-4-5 to 16-1-8, Exterior(2) 16-1-8 to
30-0-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except at=lb)
13=905, 9=1547.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek@ connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcafion, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2181V. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Truss Truss Type City Ply �20005 southern Star
T71891141
MS MONO HIP 1 1
Chambers Truss, Fort Pierce, FL, - 7.640 s Apr 22 2016 MiTek Industries, Inc. Tue Aug 22
ID:O4141 DCB7QwRG?h?eJCrfKzY77F-OEG?UXCYQnW9HuMuxVGCox33c8;
• 1-3-13 6-8-6 13-3.15 18-1-8 23-2-5 30-1--
1-0.9 6-7-10 4-9-9 s-0-13 6.11.7
cm
0
48 = 2x3 11 3x4 Scale=1:62.8
=
6.00 12 6 20 7 21 8
14 � " — 11 10 9
6x8 = 3x4 = 3x6 = 3x4 _ 6x8 = 3x4 II
3x4 =
1-3-13
9-2-6 18-1-8
23-23_ 30-1-12
1-0-07-10-8 B-11-3
5-0-13 6-11-7
0.3-13
Plate Offsets (X Y)— f4:0-3-0 Edqel f6:0-6-0 0-2-Oj f12-0-3-0 0-0-3j fl4:0-3-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/dell Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.46
Vert(LL)
0.36 11-13 >724 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.43
Vert(TL)
-0.39 11-13 >678 240
BCLL 0.0
Rep Stress Incr YES
WB 0.67
Horz(TL)
-0.03 9 n/a n1a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Weight: 202lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-8-15 oc bracing.
WEBS
1 Row at midpt 8-9, 5-13, 5-11, 6-11, 6-10, 7-10, 8-10
MiTek recommends that Stabilizers and required cross
bracing be installed during truss erection, in accordance with
Stabilizer Installation guide.
REACTIONS. (lb/size) 9= 61/Mechanical, 14=811/0-7-10, 10=1470/0-7-10
Max Harz 14=538(LC 12)
Max Uplift 9=-61(LC 1), 14=-858(LC 12), 10=-1660(LC 12)
Max Grav 9=186(LC 12), 14=811(LC 1), 10=1484(LC 2)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 258/478, 2-18=-320/649, 3-18=-227/660, 3-19=-881/1613, 4-19=-816/1614,
4-5=-801/1627, 5-6— 281/456, 6-20= 380/199, 7-20= 380/199, 7-21=-380/199,
8-21=-380/199, 8-9=-311/144
BOT CHORD 1-14= 420/234, 13-14= 2067/855, 13-22= 1193/493, 12-22=-1193/493, 12-23= 1193/493,
23-26=-1193/493, 11-26=-1193/493, 11-24— 504/209, 10-24= 504/209
WEBS 2-14— 414/367, 3-14=-759/1110, 3-13=-327/443, 5-13=-1170/453, 5-11=-544/1203,
6-11=-1547/665, 6-10=-829/1821, 7-10=-391/521, 8-10=-345/646
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft;
eave=lift Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, interior(1) 9-7-3 to 18-1-8,
Exterior(2) 18-1-8 to 30-0-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 9, 858 lb uplift at
joint 14 and 1660 lb uplift at joint 10.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 11411-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fobricatlom storage. delivery. erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety information avallable from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Jab
Truss
Truss Type
Qty
Ply
20005 Southern Star
'
T11891142
74497
M6
MONO HIP
1
1
Job Reference (optional)
Chambers Trusg, Fort Pierce, FL 7.640 s Aug 16 2017 Weir Industries, Inc. Tue Aug 22 11:42:28 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-waxXO5oMx8SSNUiawNMX5tsSsOlzbOn5T90ZZylJsP
1-3-1313-3-15 20-1.8 23-2-5 30-1-12
7-3-13 5.4-9 6-7-9 6-9-9 3.0-13 6-11-7
4x10 = Scale = 1:65.3
2x3 3x4 =
6.00 FIT 6 7 19
14 ,o — " ` 11 10 9
6x8 = 3x4 = 3x6 = 3x4 = 6x8 = 3x4 11
3x4 =
1-3-13
iI-" 10-8-10 20-1-8 _i_ _ 232-5 i 30.1-12
1-0-0 9-4-14 9-4-14 3-0d3 6•11-7 1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.51
Vert(LL) 0.40
11-13 >662 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.52
Vert(TL) -0.42
11-13 >620 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.84
Horz(TL) -0.03
9 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix-M)
Weight: 211 lb FT = 20
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 4-8-9 oc bracing.
WEBS
1 Row at midpt 8-9, 5-13, 5-11, 6-11, 6-10, 7-10, 8-10
REACTIONS. (lb/size) 9=-58/Mechanical, 14=812/0-7-10, 1 0=1 466/0-7-10
Max Harz 14=597(LC 12)
Max Uplift9=-58(LC 1), 14=-840(LC 12), 10=-1654(LC 12)
MaxGrav9=170(LC 11), 14=812(LC 1), 10=1466(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-375/676, 2-3=-369/811, 3-18= 797/1348, 4-18=-723/1348, 4-5— 665/1362,
6-7=-315/179, 7-19=-315/179, 8-19= 315/179, 8-9= 268/133
BOT CHORD 1-14=-554/294, 13-14=-1987/833, 13-20=-1276/510, 12-20=-1276/510, 12-21= 1276/510,
11-21=-1276/510
WEBS 2-14=-458/256, 3-14=-664/809, 3-13=-329/493, 5-13=-1109/462, 5-11=-653/1470,
6-11= 1601/609, 6-10= 783/1920, 7-10= 359/460, 8-10=-333/575
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=l i ft; Cat.
II; Exp C; Encl., GCpl=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 20-1-8, Exterior(2) 20-1-8 to
30-0-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 9 except Qt=lb)
14=840, 10=1654.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 10103/2015 BEFORE USE.
"
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
Is always required for stability and to prevent collapse with posslble personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, weANSI/TPI1 Qualify Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Jab
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891143
74497
M7
MONO HIP
2
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL 7.640 s Aug 16 2017 MI I ek Industries, Inc. I us Aug 22 11:42:29 2017 rage 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-PnVvcRp_iRaJ?elnU4tmd4PYSoLCKrBFipl7F?ylJsO
1.3-13 8-2-9 15-2-9 22-1-8 27-7.10 33-1-12
-313 6-t0.12 7-0-0 6-10-15
4x6 = 3x4 = 3x5 = Scale = 1:73.7
6.00 12 6 2021 7 8
14
1u GG
Gu
IG 11 —
10 9
5x8 =
3x8 =
3x5 = 3x6 II
3x4 =
3x6 =
1-3-13
1-0-0
12-0-7
22-1-8
27-7.10
31-1-12
-0-0
10-8-10
10-1-1
5-6-2
"A 3
Plate Offsets (X,Y)--
f2:0-7-13 0-3-81 f4:0-3-0 Edge1 f13:0-4-0
0-3-41
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
-0.34 11-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.58
Vert(TL)
-0.65 11-13 >587 240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.89
Horz(TL)
0.05 9 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.1311-13 >999 240
Weight: 234lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing
directly applied or 5-1-7 oc puriins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-4-7 oc bracing.
WEBS
1 Row at midpt
3-14, 5-11, 7-11, 7-10, 8-10
2 Rows at 1/3 pis
8-9
REACTIONS. (lb/size) 9=1172/0-7-10, 14=1270/0-7-10
Max Horz 14=656(LC 12)
Max Uplift9= 823(LC 12), 14= 712(LC 12)
Max Grav9=1 451 (LC 17), 14=1438(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 597/76, 2-3=-777/500, 3-18=-1973/1208, 18-19= 1964/1211, 4-19= 1906/1221,
4-5=-1847/1235, 5-6=-1134/805, 6-20=-977/838, 20-21=-977/838, 7-21=-977/838,
7-8=-599/517, 8-9= 1334/1223
BOT CHORD 1-14=-230/586, 13-14= 1861/2035, 13-22= 1451/1584, 22-23=-1451/1584,
12-23=-1451/1584,11-12= 1451/1584,11-24=-517/599,10-24=-517/599
WEBS 2-14=-558/890, 3-14=-1428/989, 3-13=-321/520, 5-13=-335/593, 5-11=-898/903,
7-11=-739/870, 7-10=-1050/1097, 8-1 0=-1 181/1367
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 22-1-8, Exterior(2) 22-1-8 to
33-0-0 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except (it=lb) 9=823,
14=712.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING - Verl/y design parameters and READ NOTES ON THIS AND INCLUDED MITERREFERANCE PAGE Mll-7473 rev. 10703/2015 BEFORE USE.
Design valid for use only with MITek6 connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MITek`
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 3M Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
,
T11891144
74497
Ms
MONO HIP
9
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL 7.640 s Aug to zo17 MITex industries, Inc. t ue Aug 22 n:42:30 zur r rage i
I D:04141 DCB7QwRG?h?eJCrfKzY77F-tz2HpngcTliAcosz2oO?AlykNChV31 W OwTVgnSyIJsN
1-313 &2.9 152-9 22-0-1 27-6-14 33-1-12
-3-13 6-10-12 7.0-0 6-9-856-14 -6-14
4x6 = 3X4 =
6.00 12 6 2021 7
3x5 = Scale = 1:73.4
14
1. «
I< 11 —
10 9
5x8 =
3x8 =
3x5 = 3x6 II
3x4 =
3x6 =
1-3-13
1-0-012-0-7
22-0-1
27.E-14
2 1-12
t-" 1D-8-10
9-11-9
5.6-14
5.6-14
0-3-13
Plate Offsets (),Y)--
f2:0-7-13 0-3-81 (4.0-3-0 Edgel (13:0-4-0 0-3-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.77
Vert(LL)
-0.33 11-13 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.58
Vert(TL)
-0.6211-13 >612 240
BCLL 0.0
Rep Stress Incr YES
WB 0.89
Horz(TL)
0.05 9 n/a n/a
BCDL 10.0
Code FBC2014/7P12007
(Matrix-M)
Wind(LL)
0.1211-13 >999 240
Weight: 233lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 5-1-7 oc puffins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-4-7 oc bracing.
WEBS
1 Row at micipt
3-14, 5-11, 7-11, 7-10, 8-10
2 Rows at 1/3 pis
8-9
REACTIONS. (lb/size) 9=1172/0-7-10, 14=1270/0-7-10
Max Harz 14=652(LC 12)
Max Uplift9=-821(LC 12), 14=-713(LC 12)
Max Grav9=1449(LC 17), 14=1437(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 599/77, 2-3=-778/500, 3-18=-1971/1214, 18-19= 1964/1217, 4-19=-1904/1227,
4-5=-1845/1241, 5-6= 1143/816, 6-20=-985/846, 20-21=-985/846, 7-21=-985/846,
7-8=-607/524, 8-9=-1332/1221
BOT CHORD 1-14=-230/587, 13-14=-1864/2033, 13-22= 1449/1581, 22-23=-1449/1581,
12-23— 1449/1581, 11-12=-1449/1581, 11-24= 524/607, 10-24=-524/607
WEBS 2-14=-554/889, 3-14=-1425/996, 3-13=-323/521, 5-13=-336/591, 5-11=-890/897,
7-11— 731/858, 7-10=-1042/1094, 8-10_ 1181/1368
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 22-0-1, Exterior(2) 22-0-1 to
33-0-0 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Provide adequate drainage to prevent water ponding.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=821,
14=713.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED mrTEK REFERANCE PAGE M11-7473 rev. 10/0"015 BEFORE USE.
'
Design valid for use only with MITek0 connectors. this design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcotlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Insfilute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
o
T11891145
74497
MV2
VALLEY
5
1
Job Reference (optional)
Cfjambers Truss, „ Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:31 2017 Page 1
ID:O4141 DCB7QwRG?h?eJCrfKzY77F-L9cf06gEE3gOExR9cVvEjVU3mbAloycY97EDJuylJsM
2-0-0
2-0-0
3X4 ':-
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL I
Plate Grip DOL
1.25
TC 0.09
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.03
Vert(TL)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(TL)
-0.00 2
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=51/2-0-0, 2=37/2-0-0, 3=14/2-0-0
Max Horz 1=41(LC 12)
Max Upliftl =-21 (LC 12), 2=-45(LC 12)
Max Gravl=55(LC 17), 2=48(LC 17), 3=28(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale = 1:7.9
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 20
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft L=100111; eave=lift Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) 1, 2.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MiTek0 connectors. This design is based only upon parameters shown, and is for on Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and Truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312 Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891146
74497
MV4
VALLEY
4
1
Job Reference (optional)
,Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11 A2:32 2017 Page 1
113:04141 DCB7QwRG?h?eJCrfKzY77F-pMA1 ESrs?Myts5OM9DRTFl17M?TgXPshOn_nsKylJsL
4-0-0
r 4-0-0
Scale = 1:13.0
3x4 5- 3x4 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.21
Vert(TL) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) 0.00 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 14lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=120/4-0-0, 3=120/4-0-0
Max Horz 1=96(LC 12)
Max Upliftl=-49(LC 12), 3= 96(LC 12)
Max Grav 1=128(LC 17), 3=145(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 4-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=11ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11111-7473 rev. 1NO3/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse wilh possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T118911 a7
74497
MV6
VALLEY
4
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL
6-0-0
f.64U s Aug 16 2017 Mirek Industries, Inc. I ue Aug 22 11:42:32 2017 rage 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-pMA1 ESrs?Myts5OM9DRTFj 1 BB?VBXNohOn_nsKylJsL
3x4 11
5 4
3x4 i 2x3 11 3x4 11
Scale = 1:18.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TOLL 20.0
Plate Grip DOL 1.25
TC 0.30
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.12
Vert(TL) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.13
Horz(TL) 0.00 n/a n/a
BCDL 10.0
Code FBC2014fTP12007
(Matrix)
Weight: 23lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=61/6-0-0, 4=83/6-0-0, 5=243/6-0-0
Max Horz 1=155(LC 12)
Max Uplift4— 67(LC 12), 5— 196(LC 12)
Max Grav 1=61(LC 1), 4=100(LC 17), 5=295(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 286/112
WEBS 2-5=229/446
Structural wood sheathing directly applied or 6-0-0 oc pudins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb)
5=196.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used In the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND /NCLUDED MirEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a ttuss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
WeIC
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
,,
T71891148
74497
MV8
VALLEY
3
1
Job Reference (optional)
Chambers Truss, , Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:42:32 2017 Page 1
ID:O4141 DCB7QwRG?h?eJCrfKzY77F-pMA1 ESrs?Myts50M9DRTFjl7f?TYXNDhOn_nsKylJsL
8-0-0
8-0-0
3x4 11
3x4 11
3x4 i 2x3 11 4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.52
Vert(LL)
Na
Na
999
TCDL 7.0
Lumber DOL
1.25
BC 0.22
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.17
Horz(TL)
0.00
n/a
Na
BCDL 10.0
Code FBC2014/TP12007
I (Matrix)
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=89/8-0-0, 4=111/8-0-0, 5=336/8-0-0
Max Horz 1=214(LC 12)
Max Uplift4=-89(LC 12), 5=-270(LC 12)
Max Grav1=89(LC 1), 4=134(LC 17), 5=406(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 366/143
WEBS 2-5=-315/571
Scale = 1:24.9
PLATES GRIP
MT20 244/190
Weight: 31 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 4 except Qt=lb)
5=270.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE MII-7473 rev- 10/0=015 BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of Trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891149
74497
Mv10
GABLE
1
1
Job Reference (optional)
Chambers Truss, * Fort Pierce, FL
3x4 i
10-0-0
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:30 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-tz2HpngcTliAcosz2oO?AlygJCkp3S9OwTVgnSylJsN
3x4 11
4 3x4 11
Scale = 1:31.1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.96
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.43
Vert(TL)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.21
Horz(TL)
-0.00 4
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 39lb FT=20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=70/10-0-0, 4=185/10-0-0, 5=428/10-0-0
Max Harz 1=273(LC 12)
Max Upl1ft4= 149(LC 12), 5=-344(LC 12)
Max Grav1=79(LC 12), 4=224(LC 17), 5=518(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-449/165, 3-4= 170/293
WEBS 2-5=-404/689
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extehor(2) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 4=149,
5=344.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI17473 rev. 10103,2015 BEFORE USE
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
prevent
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 2231A.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891150
74497
MV12
GABLE
1
1
Job Reference (optional)
Crhambers Truss, . Fort Pierce, FL
2-0-0
3X4
2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 1.00
TCDL 7.0
Lumber DOL 1.25
BC 0.57
BCLL 0.0
Rep Stress Incr YES
WB 0.22
BCDL 10.0
Code FBC2014fTP12007
(Matrix)
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=153/12-0-0, 4=174/12-0-0, 5=504/12-0-0
Max Horz 1=333(LC 12)
Max Uplift4= 141(LC 12), 5=-405(LC 12)
Max Grav1=153(LC 1), 4=282(LC 17), 5=651(LC
17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-6=-475/158, 2-6=-457/182, 3-4=162/267
WEBS 2-5=-464/735
7.640 s Aug 16 2017 ME I eK Industries, Inc. I us Aug 22 11:42:31 2017 Vega 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-L9cf06gEE3gOExR9cVvEjVUrUb2yovCY97EDJuylJsM
Scale = 1:36.3
3X4 II
3
4 3X4 I I
DEFL. in (loc) 1/deft Ud PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(TL) n/a n/a 999
Horz(TL) 0.00 4 n/a n/a
Weight: 48 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-7-7 to 10-2-10, Interior(1) 10-2-10 to 11-10-4 zone; cantilever
left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Qt=lb) 4=141,
5=405.
6) "Semi-rigld pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
A WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MI1-7473 rev. 10/03,2015 BEFORE USE.
r�
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and Is for an Individual building component. not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricatlom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891151
74497
N
COMMON
1
1
Job Reference (optional)
C4ambers Truss, , Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:33 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-HYkQRosVmg4kTFbYjwyiowal9PlcGfwgdRjKOnylJsK
1-3-13 8-6-7 15-9-10 23-0-13 29-7-4
1-3-13 7-2-10 7-&3 7-3.3 6-6-7
4x6 =
6.00 12
Scale = 1:54.2
3x4 = 3x6 =
3x4 =
6x8 =
3x4 =
1-3-13
i-0-0 11-D-7 20.6-13
-
29-7-4
1-0-0 9-6-10 9-6-6
9-0-7
0-3-13
Plate Offsets (X Y)--
f2:0-7-13 0-3-81 (3:0-4-0 0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) I/dell Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL) -0.31
8-10 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.49
Vert(TL) -0.50
8-10 >680 240
BCLL 0.0
Rep Stress Incr YES
WB 0.84
Horz(TL) 0.05
7 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.10
B-10 >999 240
Weight: 159lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 5-6-15
oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 6-10-0 oc bracing.
WEBS
1 Row atmidpt 3-11,5-7
REACTIONS. (lb/size) 11=1139/0-7-10, 7=1041/0-7-10
Max Horz 11=-356(LC 10)
Max Upliftl 1 =-746(LC 12), 7=-630(LC 12)
Max Grav11=1169(LC 17), 7=1090(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-517/162, 2-15=-681/600, 3-15=-554/614, 3-16=-1526/1390, 4-16=-1445/1415,
4-17=-1372/1403, 5-17=-1453/1388, 5-18=-182/290, 6-18=-238/276, 6-7=-251/333
BOT CHORD 1 -11 =-325/502, 10-11=-1158/1644, 10-19=-599/1050, 9-19=599/1050, 9-20= 599/1050,
8-20=-599/1050, 7-8=-1074/1281
WEBS 2-11=-547/951, 3-11 =-1 038/995, 3-10=-414/579, 4-10=-507/740, 4-8=-428/628,
5-8=-306/504, 5-7=-1378/1170
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100ft eave=lift Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-1 b to
25-4-13 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in ail areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = I O.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=746,
7=630.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MI7EK REFERANCE PAGE11111-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with M 109 connectors. This design is based only upon parameters shown, and Is for an Individual building component not
�A
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
M!Tek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
*
T11891152
74497
N1
COMMON
7
1
Job Reference (optional)
Chambers Truss* Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. I ue Aug 22 11:42:34 2017 Page 1
0:04141 DCB7QwRG?h?eJCrfKzY77F-Iklof8t7X_Db5PAkHeTxK86Tzp5o?6z_r5TuwDylJsJ
1-3-13 B-6.7 15-9-10 23-0-13 29-3-7 31-7-4
1.3.13 7-2-10 7.3-3 7-3-3 6-2-10 2-3.13
6.00 ri2
m
14
0
4x6 =
Scale = 1:55.2
3x4 =
4x6 =
3x4 = 6x8 = 3x4 =
3x4 =
i-3-13
i 1-0-0
11-D-7
2D-6-13
29-3-7 _ �7 4 T 7-4
r-0-0
9-8-10
9-6-6
8-8-10 0-$-13 2-0-0
0-3-13
Plate Offsets (),Y)--
f2'0-7-13 0-3-8) f3.0-4-0 0-3-01
(5:0-4-0 0-3-01 18:0-3-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.54
Vert(LL) -0.31
9-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.49
Vert(TL) -0.51
9-11 >664 240
BCLL 0.0 '
Rep Stress Incr YES
W B 0.86
Horz(TL) 0.05
8 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.09
9-11 >999 240
Weight: 165lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-7-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-2-15 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row atnNdpt 3-12, 5-8
REACTIONS. (lb/size) 12=1128/0-7-10, 8=1210/0-7-10
Max Horz 12=-379(LC 10)
Max Upliftl2— 740(LC 12), 8=-732(LC 12)
Max Grav12=1160(LC 17), 8=1210(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=510/161, 2-19=-677/599, 3-19=-550/612, 3-20=-1509/1343, 4-20= 1428/1368,
4-21= 1334/1272, 5-21 =-1 413/1248
BOT CHORD 1-12— 323/498, 11-12= 1030/1647, 11-23=-468/1051, 10-23=-468/1051, 10-24=-468/1051,
9-24=-468/1051, 8-9=-897/1208
WEBS 2-12=-548/948, 3-12= 1023/933, 3-11=-415/587, 4-11= 515f743, 4-9=-381/595,
5-9=-277/454, 5-8=-1326/1267, 6-8=-350/586
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 12=740,
8=732.
6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verily design peranreters end READ NOTES ON THIS ANO INCLUDED MITEK REFERANCE PAGE Mll--7473 rev. 10/173/2015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI i Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891153
74497
N2
COMMON
3
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11:42:34 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-Ikl of8t7X_Db5PAkHeTxK86TVp5Z?6g_r5TuwDylJsJ
1-3-13 B-6-7 15-9-10 23-0-13 30-3-7 3¢7r4
1.3.13 7-2-10 7-3-3 7-3-3 7-2-10 0- 3
4x6 =
6.00 r12
Scale = 1:54.8
m
Io
3x4 = 4x6 =
3x4 =
4x10 II
3X4 =
i-3-13
1-0-0 11-0.7 20.6-13
?A3-7
3¢7r4
1-09-8-10 9.6-6
9-8-10
P -13
0-3-13
Plate Offsets (X Y)--
(2:0-7-13 0-3-8j (3.0-4-0 0-3-01 (5:0-4-0 0-3-Oj j7:0-6-4 Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.57
Vert(LL) -0.33
8-10 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.51
Vert(TL) -0.54
8-10 >648 240
BCLL 0.0
Rep Stress Incr YES
W B 0.88
Horz(TL) 0.07
7 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.12
8-10 >999 240
Weight: 158lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 5-2-8
oc puriins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 6-8-9 oc bracing.
WEBS 2x4 SP No.3 WEBS
1 Row at midpt 3-11
SLIDER Right 2x8 SP 240OF 2.OE 2-6-0
REACTIONS. (lb/size) 11=1182/0-7-10, 7=1083/Mechanical
Max Horz 11=-368(LC 10)
Max Upliftl 1 =-773(LC 12), 7=-654(LC 12)
Max Grav 11 =1 206(LC 17), 7=1142(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-522/164, 2-19=-677/605, 3-19= 557/618, 3-20=-159911444, 4-20=-1518/1469,
4-21=-1537/1525, 5-21=-1616/1500, 5-22= 1663/1542, 6-22=-1758/1530, 6-7=-836/389
BOT CHORD 1-11=328/508, 10-11=-1170/1715, 10-23=-614/1126, 9-23=-614/1126, 9-24= 614/1126,
8-24= 614/1126, 7-8= 1185/1486
WEBS 2-11= 555/955, 3-11=-1116/1033, 3-10=-406/577, 4-10=-501/738, 4-8=-526/758,
5-8=-443/604
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=1501t; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=773,
7=654.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10103,2016 BEFORE USE
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
prevent
Is always required for siabiltty and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891154
74497
N3
COMMON
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:35 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-DwsAsUtIHHLSjZlwrL_AtLfdHDQTkdg741CRSfylJsl
1.3.13 8-6.7 15-9-10 23-2-5 30-3-7 3 •7 4
1-3-13 7-2-10 7.3-3 74-11 7-1-2 0.- 3
4x6 =
6.0o 12
Scale = 1:54.8
m
Io
12 •,� w
8
3x4 = 4x6 =
3x4 = 3x6 ll 4x8 l
3x4 =
1.3-13
1-0.0 11.0-7 20.6-13
212-5 30-3-7 7
i-0-0 9-8-10 9.6.6
2.7-8 7.1-2
0-3-13
Plate Offsets (X,Y)--
(1:0-0-4,Edgel, f2:0-7-9,0-3-01, (3:0-4-0,0-3-41, (5:0-4-0,0-3-41, (7:0-4-12,0-3-21
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(Ioc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL) -0.25
9-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.53
Vert(TL) -0.44
9-11 >590 240
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
W B 0.64
Horz(TL) -0.03
8 n/a rl/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL) 0.35
9-11 >739 240
Weight: 164lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 4-10-6 oc bracing.
WEBS 2x4 SP No.3 WEBS
i Row at midpt 3-12, 4-11, 4-9
SLIDER Right 2x8 SP 240OF 2.0E 2-6-0
REACTIONS. (lb/size) 12=95910-7-10, 8=880/0-7-10, 7=425/Mechanical
Max Horz 12=-368(LC 10)
Max Upliftl2= 1115(LC 12), 8=-961(LC 12), 7=-284(LC 12)
Max Grav 12=959(LC 1), 8=880(LC 1), 7=521(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-468/972, 2-20=-583/1260, 3-20=-428/1273, 3-21 =-1 083/2177, 4-21=-986/2202,
4-22= 585/1385, 5-22= 674/1360, 5-23=-470/605, 6-23=-535/591, 6-7=-443/157
BOT CHORD 1-12=-917/448, 11-12=-1826/1049, 11-24=-794/595, 10-24=-794/595, 10-25= 794/595,
9-25— 794/595, 8-9=-385/448, 7-8=-365/442
WEBS 2-12=-655/613, 3-12= 719/1105, 3-11=452/581, 4-11=-1424/590, 4-9— 259/315,
5-9=-857/462, 5-8=-814/1720
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
25-4-13 zone; cantilever left exposed; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=lb)
12=1115, 8=961, 7=284.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MII--7473 rev. 10/03/2015 BEFORE USE.
°
Design valid for use only with MITekO connectors. this design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Stor
T11891155
74497
N4
SPECIAL
1
1
Job Reference (optional)
Chambers Truss' Fort Pierce, FL 7.640 s Aug 16 2017 nn i — inuusu —, mo. g « aye ,
ID:04141 DCB7QwRG?h?eJCrfKzY77F-h7QY4quN2bTJK1K702VPQZCp7cmOT?EHJPy_?5ylJsH
1-3-13 8-6-7 15.9-10 19-5-12 26-3-12 33-1-12
1-3-13 7-2-10 7-3-3 3-8-2 6-10-0 6-10-0
4x6 =
6.00 12
Scale = 1:60.2
v
6
14
... .- --
--
11- — 9
e
3x4 =
3x6 =
4x6 = 3x6 = 3x5 =
3x6 I I
3X4 =
1-3-13
1-0-01"-7
19-5-12
26-512 33-1-72
1.0-0 9-8-10
9-5-5
6-10-0 6-10-0
03-13
Plate Offsets (X,Y)--
(2:0-7-13 0-3-81 13:0-4-0 0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in (loc) I/dell L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.56
Vert(LL)
-0.22 11-13 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.49
Vert(TL)
-0.42 11-13 >907 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.94
Horz(TL)
0.05 8 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.1411-13 >999 240
Weight: 200lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc puriins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-8-11 oc bracing.
WEBS
1 Row at midpt 7-8, 3-14, 7-9
REACTIONS. (lb/size) 8=1172/0-7-10, 14=1270/0-7-10
Max Harz 14=360(LC 12)
Max Uplift8=-743(LC 12), 14=-792(LC 12)
Max Grav8=1276(LC 17), 14=1353(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 545/150, 2-18=-753/580, 3-18=-627/594, 3-19=-1877/1468, 4-19= 1797/1493,
4-5=-1883/1565, 5-20= 165511332, 20-21= 166511332, 6-21 =-1 655/1332, 6-7=-1144/950,
7-8— 1157/1055
BOT CHORD 1-14= 308/565, 13-14=-1652/1869, 12-13=-1095/1315, 12-22= 1095/1315,
22-23= 1095/1315, 11-23=-1095/1315, 10-11=-950/1144, 10-24=-95011144,
9-24=-950/1144
WEBS 2-14=-554/934, 3-14= 1299/1084, 3-13=-390/578, 4-13=-505/686, 4-11= 633/946,
5-11=-994/960, 6-11=-517/693, 6-9=-830/906, 7-9=-1272/1531
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=1501t; L=100ft eave=11ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
19-5-12 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 011=1b) 8=743,
14=792.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used In the analysis and design of this truss.
0 WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE M11--7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design info the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Job
Truss
Truss Type
city
Piy
20005 southern Star
T11891156
74497
N5
SPECIAL
1
1
Job Reference (optional)
C� ambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MITek Industries, Inc. I us Aug 22 11:42:37 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-AJzwHAv?pvbAysvJymOeymkxZO5CCTdQX3hYXYylJsG
t-3-73 B-6-7 15-9-10 17-5-12 25-3-12 33-1-12
1-3-13 7-2-10 7-3-3 1-8-2 7-10-0 7-10-0
Scale = 1:60.2
5x6 =
6.00 12 4 4x6 = 3x4 = 4x4 =
14 ,., — _" 11
._ _. 9 __
8
3x4 = 3x6 = 3X8 =
3x6 = 3x5 =
3x6 I1
3X4 =
i-3-13
i-0-0 11-0-7 17-5-12
25-3-12 33-1-12
t•0-0 9-5-10 6-s-5
7-10-0 7.10-0
0.3-13
Plate Offsets (X Y)--
(2:0-7-13 0-3-81 (3:0-4-0 0-3-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.64
Vert(LL) -0.14
13-14 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.51
Vert(TL) -0.38
13-14 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.86
Horz(TL) 0.05
8 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wlnd(LL) 0.1311-13
>999 240
Weight: 207lb
FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 4-11-14 oc purlins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 5-7-11 oc bracing.
WEBS
1 Row at midpt 7-8, 3-14, 7-9
REACTIONS. (lb/size) 8=1172/0-7-10, 14=1270/0-7-10
Max Horz 14=419(LC 12)
Max Uplift8=-755(LC 12), 14= 780(LC 12)
Max Grav8=1322(LC 17), 14=1371(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 578/134, 2-18=-796/564, 3-18=-669/578, 3-19= 1898/1454, 4-19= 1818/1479,
4-5=-1680/1390, 5-20=-150611235, 20-21 =-1 506/1235, 6-21= 150611235, 6-7= 1138/930,
7-8— 1181 /1077
BOT CHORD 1-14=-294/602, 13-14= 1701/1872, 12-13=-1145/1355, 12-22= 1145/1355,
22-23= 1145/1355, 11-23=-1145/1355, 10-11=-930/1138, 10-24=-930/1138,
9-24=-930/1138
WEBS 2-14=-538/932, 3-14=-1276/1070, 3-13=-387/574, 4-13=-506/618, 4-11=-518/844,
5-11= 862/802, 6-11= 416/501, 6-9=-766/906, 7-9=-1250/1529
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft eave=l ift; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 15-9-10, Exterior(2) 15-9-10 to
17-5-12 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = I O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=755,
14=780.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - VerW design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
'
T11891157
74497
N6
MONO HIP
1
1
Job Reference (optional)
Cbambers.Truss, Fort Pierce, FL 7.640 s Aug to 2017 Mirea industries, Inc. rue Aug cc 1 :42:37 2017 rage 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-AJzwHAv?pvbAysvJymOeymkwKO7gCRUQX3hYXYyIJsG
1-3-13 M-10 16-1-8 24-7-10 33-1-12
1-3-13 7A-14 7-4-14 B-6-2 8-6-2
Scale = 1:58.1
4x6 =
3x4 = 4x6 = 4x5 =
6.00 12 4 2021 5 622
14 13
'-
11
-
a
0
3x4 = 4x4 =
3x6 =
3x8 =
3x6 =
3x5 =
3x6 II
1-3-13
i-0-0 0-8-10
16-1-8
24-7-10
33-1-12
i-0-0 7.4-14 17.4-14
B-6-2
8.6-2
0-3-13
Plate Offsets (X,Y)--
(2:0-2-12 0-1-Oj (3:0-4-0 0-3-41 (4:0-3-8 0-2-01 (6:0-3-0 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl
Lid
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL)
-0.12 9-11 >999
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.41
Vert(TL)
-0.30 8-9 >999
240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
WB 1.00
Horz(TL)
0.04 8 n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.11 11-13 >999
240
Weight: 200lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood
sheathing directly applied or 5-0-10
oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied
or 5-6-2 oc bracing.
WEBS
1 Row at midpt
7-8, 3-11, 5-9, 7-9
REACTIONS. (lb/size) 8=1171/0-7-10, 14=1271/0-7-10
Max Horz 14=478(LC 12)
Max Uplift8= 768(LC 12), 14=-767(LC 12)
Max Grav8=1 331 (LC 17), 14=1354(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-440/105, 2-18=-1997/1443, 3-18= 1865/1469, 3-19= 1508/1147, 4-19=-1427/1172,
4-20— 1314/1177, 20-21=-1314/1177, 5-21=-1314/1177, 5-22=-1064/899, 6-22=-1064/899,
6-7=-1064/899, 7-8=-1173/1111
BOT CHORD 1-14=-272/500, 13-14= 914/665, 12-13= 1790/1837, 11-12= 1790/1837, 11-23=-899/1064,
10-23=-899/1064, 9-10— 899/1064
WEBS 2-14=-1278/1384, 2-13=-878/1178, 3-11— 614/713, 4-11=-62/328, 5-11=-387/349,
5-9=-732/921, 7-9=-1234/1459
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterbor(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 16-1-8, Exterior(2) 16-1-8 to
29-8-7 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=768,
14=767.
8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll--7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
61IiOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891158
74497
N7
MONO HIP
1
1
Job Reference (optional)
Chambers Trust, Fort Pierce, FL I.tM 3 Aug 1 b ZU1 I MI I eK alausines, Inc. I ue Aug ez 11:YZ:00 e 1 / rage i
I D:04141 DCB7QwRG?h?eJCrfKzY77F-eVXJ U Wwdaq 1 aOUV W TXtV_H6UQTvxwkZmj R53 ylJsF
1-3-13 9-8-10 18-1-8 25-7-10 33-1-12
1-3-13 8-4-14 B-4-14 7-6-2 7-6-2
46 =
3x4 =
Scale = 1:61.0
4x4 =
6.00 F12 5 1920 6 21 7
m
a
a
4x4 =
3x6 =
3x8 =
3x6 = 3x5 = 3x6 Ii
3x4 =
1-3.13
9-8-10
18-1-8
25.7-10 33-1-12
1-0-0 8-4-14
8.4-14
7-6-2 7-6-2
0-3.13
Plate Offsets (X,Y)--
(2:0-2-12 0-1-Oj (4:0-3-0 Edgel (5:0-3-8 0-2-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.69
Vert(LL)
-0.10 9-11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.42
Vert(TL)
-0.29 11-13 >999 240
BCLL 0.0 '
Rep Stress Incr YES
W B
0.81
Horz(TL)
0.04 8 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix-M)
Wind(LL)
0.11 11-13 >999 240
Weight: 209 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-10-10 oc puriins,
BOT CHORD 2x4 SP M 30
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-5-11 oc bracing.
WEBS
1 Row at midpt 7-8, 2-13, 3-11, 6-11, 6-9, 7-9
REACTIONS. (lb/size) 8=1171/0-7-10, 14=1271/0-7-10
Max Horz 14=538(LC 12)
Max Uplift8=-783(LC 12), 14— 751(LC 12)
Max Grav8=1357(LC 17), 14=1364(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-514/127, 2-18=-2007/1404, 3-18=-1858/1424, 3-4=-1385/1017, 4-5=-1292/1047,
5-19=-1195/1082, 19-20=-1195/1082, 6-20=-1195/1082, 6-21=-879/755, 7-21=-8791755,
7-8=-1215/1146
BOT CHORD 1-14=-343/593, 13-14= 1022/778, 12-13=-1811/1856, 11-12=-1811/1856, 10-11=-755/879,
9-10=-755/879
WEBS 2-14=-1303/1452, 2-13=-834/1081, 3-13=0/283, 3-11=-765/840, 5-11=-1/280,
6-11=-520/503, 6-9= 788/977, 7-9=-1188/1382
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft L=100ft; eave=lift; Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterlor(2) 0-0-0 to 9-8-10, Interior(1) 9-8-10 to 18-1-8, Exterior(2) 18-1-8 to
31-8-7 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 8=783,
14=751.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MY-7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria- VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Star
�
T71891159
74497
N8
MONO HIP
1
7
Job Reference (optional)
C�h ambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:39 2017 Page 1
' I D:O4141 DCB7QwRG?h?eJCrfKzY77F-6i5hisxFLW ruBA2i4B361 Bq FogoygMaj?NAecQyIJSE
,1-3-13 7-7.1 13-10-4 20-1-8 , 26-7-10 33-1-12
i-3-13 6-Li 6-3-4 6-3-4 6-6-2 6-6-2
4x6 =
6.00 FIT 6
2122
3x4 = 3x5 =
Scale = 1:69.3
15,
o <o
<w
12
10 <.. 9
3x6 =
3x8 =
3x5 = 3x6 II
3x4 =
3x4 =
3x6 =
1-3-73
it•0-0 10-8-10
20-1-8
17-10
33-7.12
�1.0-0 94-14
"-14
6-6-2
0-3-13
Plate Offsets (Y Y)--
f2:0-7-13 0-3-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.79
Vert(LL)
-0.24 12-14 >999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.49
Vert(TL)
-0.49 12-14 >769
240
BCLL 0.0
Rep Stress Incr YES
WB 0.83
Horz(TL)
0.05 9 n/a
n/a
BCDL 10.0
Code FBC2014[TP12007
(Matrix-M)
Wind(LL)
0.12 12-14 >999
240
Weight: 223lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood
sheathing directly applied or 5-0-14 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD Rigid ceiling directly applied or 5-4-4 oc bracing.
WEBS
1 Row at midpt
8-9, 3-15, 5-12, 7-12, 7-10, 8-10
REACTIONS. (lb/size) 9=1172/0-7-10, 15=1270/0-7-10
Max Horz 15=597(LC 12)
Max Uplift9= 803(LC 12), 15= 732(LC 12)
Max Grav9=1 421 (LC 17), 15=1433(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 482/75, 2-19= 685/434, 3-19= 575/445, 3-20=-2024/1342, 4-20= 1965/1345,
4-5=-1911/1358, 5-6= 1288/954, 6-21 =-1 120/962, 21-22= 1120/962, 7-22=-1120/962,
7-8=-744/633, 8-9=-1291/1186
BOT CHORD 1-15=-195/510, 14-15=-1884/2018, 13-14=-1516/1647, 13-23=-1516/1647,
23-24=-1516/1647, 12-24=-1516/1647, 11-12=-633/744, 11-25=-633/744, 10-25= 633/744
WEBS 2-15=-514/776, 3-15=-1527/1099, 3-14=-249/456, 5-14=-310/510, 5-12= 782/818,
6-12= 33/253, 7-12=-619/706, 7-10=-928/1041, 8-1 0=-1 179/1384
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=l ift; Cat.
II; Exp C; Encl., GCpt=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 9-7-3, Interior(1) 9-7-3 to 20-1-8, Exterior(2) 20-1-8 to
33-0-0 zone; cantilever left exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) 9=803,
15=732.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03(2015 BEFORE USE.
°
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual thus web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610,
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891160
74497 *
PBA
GABLE
i
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
1-11-15
1-11-15
4x5 =
US =
7.640 s Aug 16 2011 MI I eK Inclusines, Inc. I Ue Aug L'L 11:42:39 2U1 r I -age 1
1 D:0414l DCB7QwRG?h?eJCrfKzY77F-6i5hisxFLW ruBA2i4B361 BgEjgp7gZbj?NAecQylJsE
6-3-10
4-3-11
5x6 II
4
Scale = 1:12.5
6-3-10
Plate Offsets (X,Y)--
f3.0-3-0 0-2-01 f4•Edge 0-3-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.86
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.42
Vert(TL) n/a n/a 999
BCLL 0.0 *
Rep Stress Incr NO
WB 0.00
Horz(TL) 0.00 6 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 18lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except* TOP CHORD
3-4: 2x4 SP M 30
BOT CHORD 2x4 SP No.3 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1— 109/6-3-10, 6=180/6-3-10, 2=362/6-3-10
Max Horz 1=50(LC 12)
Max Upliftl=-109(LC 17), 6=-108(LC 12), 2=-261(LC 12)
Max Gram 1=109(LC 12), 6=180(LC 1), 2=363(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-290/91, 2-3= 232/543, 3-4=-178/448, 5-6=-180/409, 4-5=-125/412
BOT CHORD 2-5=-448/178
Structural wood sheathing directly applied or 6-0-0 oc pudins, except
end verticals.
Rigid ceiling directly applied or 8-3-8 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as perANSI/TPI 1.
4) Provide adequate drainage to prevent water pending.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=109,
6=108, 2=261.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, The building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Welk'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
.
T11891161
74497
PBB
GABLE
1
1
Job Reference (optional)
. Chambers Truss, Fort Pierce, FL
17-9-11
r.640 a Aug i6 20i r MiTek mOuslrles, Inc. I ue Aug 22 11 :42.40 2017 Fagg I
ID:04141 DCB7QwRG?h?eJCrfKzY77F-auf3vBxu6gzlpKduduaLaPMZ?EDmP_asElwCBtyIJsD
4x4 =
Scale: 3/8"=1'
3x4 I
7
3x4 = 13 12 11 10 9 8
2x3 11 3x6 =
2x3 11 2x3 11
3x4 =
1 rD
I�
14 d
17-9-11
Plate Offsets (X,Y)--
f3.0-5-4 0-1-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.24
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.14
Vert(rL) n/a n/a 999
BCLL 0.0 '
Rep Stress Incr NO
W B 0.15
Horz(TL) 0.00 14 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 58 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 'Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
7-14: 2x4 SP M 30
REACTIONS. All bearings 17-9-11.
(lb) - Max Harz 1=110(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 2, 9, 8 except 13=-205(LC 12), 10=-163(LC 12), 12=-302(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 2, 9, 8 except 13=319(LC 1), 10=311(LC 1), 12=477(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-259/54
WEBS 3-13=-223/409, 5-10= 225/328, 4-12=-358/490
NOTES-
1) Wind: ASCE 7-10; VuIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-3-15 to 11-7-2, Exterior(2) 11-7-2 to 15-6-0, Comer(3) 15-6-0 to
17-7-15 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 14, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 9, 8 except
Qt=lb) 13=205, 10=163, 12=302.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MOO connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTe k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
zoo05 Southern Star
T11891162
74497
PBC
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mirek Industries, Inc. Tue Aug 22 11:42:41 2017 Page 1
' ID:04141 DCB7QwRG?h?eJCrfKzY77F-24DR7XyWt75cRUC4Bc5a7cvj8dZs8RbOShflgJylJsC
3-11-15 17-6-0 17-9-11
3-11-15 13-6-1 0-3- 1
Scale = 1:31.5
3x4 II
13
4x5 = 12 11 10 9 8
2x3 13x6 = 2x3 I I 2x3 11 3x4 =
Plate Offsets (X,Y)--
[3:0-3-0 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/dell Ud
PLATES GRIP
TCLL 20-0
Plate Grip DOL 1.25
TC 0.28
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.15
Vert(TL), n/a n/a 999
BCLL 0.0
Rep Stress Incr NO
WB 0.16
Horz(TL) 0.00 13 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 62lb FT=20
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 S P M 30 'Except` SOT CHORD Rigid cerfrng directly appfted or 6-0-0 oc bracing.
6-9: 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-9-11.
(lb) - Max Horz 1=173(LC 12)
Max Uplift All uplift 100lb or less at joint(s) 8, 9 except 1= 221(LC 17), 10— 248(LC 8), 12= 295(LC 12),
2=-351(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 8, 9 except 1=258(LC 12), 10=395(LC 1), 12=437(LC 1), 2=443(LC
17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 572/173
WEBS 5-10=-290/375, 4-12=-315/535
NOTES-
1) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-3-16 to 13-7-2, Exterior(2) 13-7-2 to 17-7-15 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 13, 8 considers parallel to grain value using ANSI/TP1 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9 except Qt=1b)
1=221,10=248,12=295,2=351.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer,
WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11--7473 rev, 1010312015 BEFORE USE
Design valid for use only with MITeW connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
buliding design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTe k°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891163
74497
PBD
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
5-11-15
5x6 =
7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:42 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-W HnpKtzBeRDT2enHlJcpfgRtA1 rGtuV9hLPJCiyIJsB
17-6-0 17-9-11
11-6-1 013- 1
2x3 11
Scale = 1:31.5
4x10 =
4x5 = 11 10 9 3x4 i 7
2x3 I I 8 2x3 I I 3x4 =
3x6 =
17-9-11
17-9-11
Plate Offsets (x,Y)--
j4:0-3-0,0-2-01,f6:0-0-8,0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL, in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(TL) n/a n/a 999
BCLL 0.0
Rep Stress Incr NO
WB 0.18
Horz(TL) 0.01 12 n/a n/a
BCDL 10.0
Code FBC2014lf-P12007
(Matrix)
Weight: 72lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except
BOT CHORD 2x4 SP M 30 end verticals. Except:
WEBS 2x4 SP M 30 1 Row at micipt 6-8
OTHERS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings 17-9-11.
(lb) - Max Horz 1=173(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-255(LC 17), 9=-313(LC 8), 11= 259(LC 12), 2=-376(LC
12), 7= 106(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 8, 7 except 1=271(LC 12), 9=466(LC 1), 11=424(LC 17), 2=494(LC
17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-661/179
WEBS 5-9=-359/478, 3-11=292/610
NOTES-
1) Wind: ABC 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-3-15 to 15-7-2, Exterior(2) 15-7-2 to 17-7-15 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSUTPI 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 12, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 255 lb uplift at joint 1, 313 lb uplift at joint 9,
259 lb uplift at joint 11, 376 lb uplift at joint 2 and 106 lb uplift at joint 7.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
A WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE M11--7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITOW connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual It=web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricaTlom storage, delivery, erection and bracing of trusses and truss systems; seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T71891164
74497 �
PBE
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
7-11-15
3x6 =
1.640 s Aug i 6 20i 7 MI I ek industries, Inc. i ue Aug 22 I 1 A2.43 2017 ruyu 1
1D:04141 DCB7QwRG?h?eJCrfKzY77F-_TLCYD_mPILKgnMTJ172C1_2KRE2cKrJw?BslBylJsA
2x3 11
Scale = 1:31.6
3x4 11
ID
4x5 = 10 9 8 /
3x5 11 3x6 = 2X3 11 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.37
Vert(LL)
n/a n/a
999
TCDL 7.0
Lumber DOL
1.2.5
BC 0.16
Vert(TL)
n/a - n/a
999
BCLL 0.0
Rep Stress Incr
NO
WB 0.24
Horz(TL)
0.00 11 n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
PLATES GRIP
MT20 244/190
Weight: 66 lb FT = 20°!
Tr
0
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiffng directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-9-11.
(lb) - Max Horz 1=228(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) except 1=-227(LC 17), 2=-316(LC 12), 8=-288(LC 12), 10=-312(LC
12), 7=-114(LC 8)
Max Gray All reactions 250 lb or less at joint(s) 7 except 1=254(LC 12), 2=452(LC 17), 8=473(LC 1), 10=469(LC
17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-757/200, 2-3= 349/82
WEBS 5-8=-347/492, 3-10=-352/804
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as perANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 11, 7 considers parallel to grain value using ANSIIfPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 227 Ito uplift at joint 1, 316 lb uplift at joint 2
, 288 lb uplift at joint 8, 312 lb uplift at joint 10 and 114 lb uplift at joint 7.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
© WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII--7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual it=web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrical[on, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891165
74497 `
PBF
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
5-11-15
Sx6 =
r.oau s Aug 16 zur r iviff ek mausmes, inc. rue Aug 22 i i.42.43 2017 rye
I D:04141 DCB7QwRG?h?eJCrfKzY77F-_TLCYD_mPILKgnMTJ 172C 1_2vRE2cL1Jw?BsiBylJsA
2x3 11
12
Scale = 1:31.2
3x4 11
1 T
I7
11 d
4x5 = 10 9 8 I
2x3 1 3x6 = 2x3 11 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.33
Vert(LL)
n/a n/a
999
TCDL 7.0
Lumber DOL
1.25
BC0.16
Vert(TL)
n/a n/a
999
BCLL 0.0
Rep Stress Incr
NO
WB 0.17
Horz(TL)
0.00 11 n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
PLATES GRIP
MT20 244/190
Weight: 63 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 20 SP No.3
REACTIONS. All bearings 17-9-11.
(lb) - Max Horz 1=169(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-263(LC 17), 2=-378(LC 12), 8=-306(LC 8), 10= 258(LC
12), 7=-111(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 7 except 1=268(LC 12), 2=519(LC 17), 8=495(LC 22), 10=395(LC
17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2— 656/181
WEBS 5-8= 368/481, 3-10=-278/584
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-3-15 to 15-7-2, Exterior(2) 15-7-2 to 17-7-15 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as perANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 11, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 263 Ib uplift at joint 1, 378 lb uplift at joint 2
, 306 lb uplift at joint 8, 258 lb uplift at joint 10 and 111 lb uplift at joint 7.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPIi Quallty Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Salety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891166
74497
PBG
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
I 3-11-15 I
3-11-15
3x6 = 2x3 I
6.00 F12 3 4
2x3 11
/.ti4V S Aug It, ZVI / MI I eK industries, inc. I ue Aug 22 I I :4L:44 GU i ! rage i
ID:04141 DCB7QwRG?h?eJCrfKzY77F-SfvalZ_OA2TAIxxfskeHkFX7?raFLogS8fuPHeylJs9
17-9-11
13-9-12
2x3 11
12
Scale = 1:31.2
3x4 II
6
4x4 = 10 9 8 7
3x6 = 2x3 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.76
Vert(LL)
n/a
Na
999
TCDL 7.0
Lumber DOL
1.25
BC 0.17
Vert(TL)
Na
n/a
999
BCLL . 0.0 '
Rep Stress Incr
NO
W B 0.14
Horz(TL)
0.00 11
Na
Na
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
3x4 =
PLATES GRIP
MT20 244/190
Weight: 58 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except* TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except
3-6: 2x4 SP M 30 end verticals.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2X4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-9-11.
(lb) - Max Horz 1 =1 1 O(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-175(LC 17), 2=-304(LC 12), 8=-297(LC 8), 10=-251(LC
12), 7= 118(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 2=423(LC 17), 8=489(LC 22), 10=396(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-431/125
WEBS 5-8=-360/456, 4-10=-279/466
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) 0-3-15 to 13-7-2, Extedor(2) 13-7-2 to 17-7-15 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9). Bearing at joint(s) 11, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 1, 304 lb uplift at joint 2
, 297 lb uplift at joint 8, 251 lb uplift at joint 10 and 118 lb uplift at joint 7.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Q WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MI FEKREFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek0 connecfors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricaflom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA22314.
Jab
Truss
Truss Type
city
Ply
201105 Southern Star
T11891167
74497
PBH
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
6.00 r12 4x4 =
2x3 11
7-9-11
7.640 s Aug 16 2017 Milrek Industries, Inc. Tue Aug 22 11:42:45 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-xsSyyv?OxMb 1v5W rQR9W HS3PoEwA4FgbNJdzp4ylJs8
2x3 11
Scale = 1:31.2
3x4 11
3x4 = 11 10 9 8 7
2x3 11
2x3 11
3x6 = 2x3 11
17-9-11
17-9-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.31
Vert(LL)
n/a
r1/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.19
Vert(TL)
n/a
n/a
999
BCLL 0.0
Rep Stresslncr
NO
WB 0.14
HOrz(fL)
0.01 12
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
3x4 =
PLATES GRIP
MT20 244/190
Weight: 54 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except` TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, except
3-6: 2x4 SP M 30 end verticals.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 17-9-11.
(Ib) - Max Horz 1=50(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 2, 11 except 12=-114(LC 12), 8— 300(LC 12), 10— 231(LC 8)
Max Grav All reactions 250 lb or less at Joint(s) 1, 12, 2, 11 except 8=495(LC 1), 10=377(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 5-8=-360/487, 4-10=-278/381
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100ft eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-3-15 to 11-7-15, Exterior(2) 11-7-15 to 17-7-15 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI TPI 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at Joint(s) 12 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11 except Qt=lb)
12=114,8=300,10=231.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Q WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 101032015 BEFORE USE.
Design valid for use only with MRek9 conneciors. This design Is based only upon parameters shown, and Is for on Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate InsTitule, 218 N. Lee Street. Suite 3M Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Star
T71891168
74497
PBK
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
ifcm
7.640 a AUg 16 2017 MI I eK Inaustrles, Inc. I ue Aug 22 11:42Ats 2u1 r Pagel
I D:04141 DCB7QwRG?h?eJCrfKzY77F-P20KAFOfigj uXF52_ghlggcSAeEYoiTiczN W LWylJs7
Scale = 1:19.4
4x4 = 2x3 11 3x4 I I
6.00 12 3 4 5
3x4 =
2x3 11
2x3 11
11-1-11
11-1-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Lid
TCLL 20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.31
Vert(TL)
n/a
n/a
999
BOLL 0.0 '
Rep Stress Incr
NO
W B 0.18
Horz(TL)
0.00 9
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
3x4 =
PLATES GRIP
MT20 244/190
Weight: 34 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.3 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 11-1-11.
(lb) - Max Horz 1=54(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 2 except 8=-111(LC 12), 7= 232(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 9, 2, 8 except 7=375(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 3-8=-125/336, 4-7=-277/616
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=10011; eave=2ft Cat.
II; Exp C; Encl., GCpl=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 9 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify capacity
of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 2 except (jt=lb)
8=111, 7=232.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
0 WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mffek'
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891169
74497
PBL
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:46 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-P20KAFOfigjuXF52_9hlggcVleB?ohvlczNWLWylJs7
i 4-1-7 11-1-11 i
4-1-7 7-0-4
6.00 12
4x4 =
Scale = 1:19.4
3x6 = 3x6 II 3x4 =
4 5
2x3 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.58
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(TL)
n/a -
n/a
999
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.22
Horz(TL)
0.00 8
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
3X4 =
PLATES GRIP
MT20 244/190
Weight: 37 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 'Except' TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins, except
3-5: 2x4 SP M 30
end verticals.
BOT CHORD 2x4 SP No.3 BOT CHORD
Rigid celfing directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-1-11.
(lb) - Max Horz 1=113(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-108(LC 10), 2= 215(LC 12), 6=-123(LC
8), 7= 265(LC 12)
Max Gray All reactions 250 lb or less at joint(s) 1, 6 except 2=313(LC 17), 7=408(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 437/114, 5-6=-150/314
WEBS 4-7=-289/738
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tali by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 1, 215 lb uplift at joint 2
, 123 lb uplift at joint 6 and 265 lb uplift at joint 7.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Q WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T1i891170
74497 '
PBM
GABLE
1
1
Job Reference (optional)
Chambers Truss,
Fort Pierce, FL
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:47 2017 Page i
I D:04141 DCB7QwRG?h?eJCrfKzY77F-tEaiNb
l HTzrl9PgEYsC_Mt9by2XJX81urd64uzy1Js6
i
6-1-7
,
10-8-4
r
6-1-7
4-6-13
Scale = 1:20.5
46 =
3x4 =
4
5
3x5
11
3
6.00 12
v
6
N N
2
1
�
I�
8 O
4x4 =
7
6
3x5 I
I
3x4 =
11-1-11
11'1-11
Plate Offsets (X Y)--
f2:0-1-12 0-0-0) (5:0-2-0 0-0-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.90
Vert(LL)
n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.46
Vert(TL)
n/a
n/a 999
BCLL 0.0 '
Rep Stress Incr NO
WB
0.25
Horz(TL)
0.00
8 n/a n/a
BCDL 10.0
Code FBC2014/ TPI2007
(Matrix)
Weight: 43 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 *Except* TOP CHORD
Structural wood sheathing directly applied or 5-8-4 oc purlins, except
4-5: 2x6 SP No.2
end verticals.
BOT CHORD 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-1-11.
(lb) - Max Harz 1=168(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1= 160(LC 17), 7=-279(LC 12), 2=-267(LC 12), 6=-126(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 7=427(LC 17), 2=368(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-633/169, 5-6=-150/319
WEBS 3-7=-307/829
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding. .
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 8, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint 1, 279 lb uplift at joint 7
, 267 lb uplift at joint 2 and 126 lb uplift at joint 6.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10M)2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, The building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information avallable from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891171
74497
PBN
GABLE
t
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Tue Aug 22 11 A2:48 2017 Page 1
+ ID:04141DCB7QwRG?h?eJCrfKzY77F-LR85bx2vEHzcnZFQ5ajDv5hxOSygGbL23HsdOPyIJs5
8-1-7 i 8-8-4
8-1-7 0-6-13 2-5.7
4x4 =
Scale = 1:26.0
4x4 = -
2x3 11 2x3 11 3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.07
Vert(TL)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr
NO
WB 0.22
Horz(TL)
-0.00 6
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
T
Ir
0
PLATES GRIP
MT20 244/190
Weight: 45 lb Fi' = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP M 30 *Except* BOT CHORD
Rigid ceiling directly applied or i0-0-0 oc bracing.
4-7: 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-1-11.
(lb) - Max Horz 1=162(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 6, 7 except 1=-200(LC 17), 8= 244(LC 12), 2=-281(LC 12)
Max Grav All reactions 250 Ito or less at joint(s) 1, 6, 7 except 8=373(LC 17), 2=388(LC 17)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-692/207, 2-3=-312/125
WEBS 3-8=-286/748, 4-7=-141/279
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7 except (jt=lb)
1=200, 8=244, 2=281.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MII--7473 rev. f0/03/2015 BEFORE USE
Design valid for use only with MITek0 connectors. this design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek+
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricatlom storage, delivery, erection and bracing of trusses and thus systems, seeANSI/TPIi Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
Ttta91172
74497 '
PBO
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
a
ORM
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:48 2017 Page 1
1D:04141 DCB7QwRG?h?eJCrfKzY77F-LR85bx2vEHzcnZFQ5ajDv5hojSwNGbS23HsdQPylJs5
4x4 =
3x4 II Scale = 1:25.0
4x4 = 8 7 6
2x3 11 2x3 11 3x4 =
� 11-1-11
11-1-11
LOADING (psf)
SPACING-
2-0-0 I
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.77
TCDL
7.0
Lumber DOL
1.25
BC 0.22
BCLL
0.0 '
Rep Stress Incr
NO
WB 0.22
BCDL
10.0
Code FBC2014/fP12007
(Matrix)
DEFL. in (loc) I/dell Ud PLATES GRIP
Vert(LL) n/a n/a 999 MT20 244/190
Vert(TL) n/a n/a 999
Horz(TL) -0.00 6 n/a n/a
Weight: 46 lb FT = 20
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
Structural wood sheathing directly applied or 4-11-3 oc puffins, except
BOT CHORD 2x4 SP No.3
end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-1-11.
(Ib) - Max Harz 1=232(LC 12)
Max Uplift All uplift 100 lb or less at joints) 6 except 1= 195(LC 17), 2=-285(LC 12), 8=-235(LC 12), 7=-129(LC
12)
Max Grav All reactions 250 lb or less at joint(s) 1, 6, 7 except 2=399(LC 17), 8=358(LC 17)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-819/221, 2-3=-424/105
WEBS 3-8=-273/723, 4-7=-144/385
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/fP1 1.
3) Provide adequate drainage to prevent water ponding.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI(TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except Qt=lb) 1 =1 95
, 2=285, 8=235, 7=129.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
0 WARNING - V fify design parameters and READ NOTES ON THIS AND INCLUDED MrTEKREFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
We[(
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricaliom storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DS8.89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22.314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891173
74497
PBP
GABLE
1
1
Job Reference (optional)
Chambers Truss, . Fort Pierce, FL
7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:49 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-pdiToG2X_b5TOipdfHESRIE?YsG??2xBlxbAyrylJs4
Scale = 1:20.6
3x6 =
2x3 11
3x4 11
9 8 7
3x5 =
2x3 I 2x3 I I 3x4 =
11-1-11
i 1-1-11
Plate Offsets (X Y)--
f2:0-0-4 0-0-01 f4:0-3-0 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.64
Vert(LL) n/a n/a 999
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.19
Vert(TL) n/a n/a 999
BCLL 0.0
Rep Stress Incr NO
WB 0.20
Horz(TL) 0.00 10 n/a n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 42lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins, except
BOT CHORD 2x4 SP No.3
end verticals.
WEBS 2x4 SP No.3 BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-1-11.
(lb) - Max Horz 1=173(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 7 except 2=-159(LC 12), 9=-224(LC 12), 8=-169(LC
12)
Max Grav All reactions 250 lb or less at joint(s) 1, 2, 7 except 9=336(LC 17), 8=273(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-551/143, 2-3= 315/79
WEBS 3-9=-255/675, 5-8= 202/478
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Bearing at joint(s) 10, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except Qt=lb)
2=159, 9=224, 8=169.
11) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building
designer.
WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEKREFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is fused only upon parameters shown, and Is for an individual building component. not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
ek'
M! lT
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T11891174
74497 •
V4
VALLEY
3
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 mi I eK Industries, ino. rue Aug 22 11:4z:49 L01 1 Pagel
ID:04141 DCB7QwRG?h?eJCrfKzY77F-pdi7oG2X_b5TOipdfHESRIE7VsHe?5381xbAyrylJs4
2-0-0 i 4-0-0
r 2-0-0 2-"
3x4 i
3x6 = Scale = 1:7.8
2
4-0-0
3x4 O
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. In
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.13
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.15
Vert(TL) n/a
n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(fL) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
Weight: 11 lb Fr = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-0-0 oc puriins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=102/4-0-0, 3=102/4-0-0
Max Horz 1=-33(LC 10)
Max Upliftl=-62(LC 12), 3=-62(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=1501t; L=100ft eave=llit; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
®WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 1111I--7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members oNy. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
r11as1r7s
74497 •
V8
VALLEY
3
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL
3x4
2x3 11
4x4 =
8-0-0
8-0-0
7.640 s Aug 16 2017 M7ek Industries, Inc. Tue Aug 22 11:42:50 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-HpGrOc391uEKOsOpD?Ih_WnCXFcDkX3KXaLkUlylJs3
8-0-0
4-"
3x4
Scale = 1:15.0
LOADING (psf)
TCLL 20.0
TCDL 7:0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2014/TP12007
CSI.
TC 0.56
BC 0.19
WB 0.08
(Matrix) '
DEFL. in
Vert(LL) n/a
Vert(fL) n/a
Horz(fL) 0.00
(loc) I/dell L/d
n/a 999
n/a 999
3 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 25 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=125/8-0-0, 3=125/8-0-0, 4=250/8-0-0
Max Horz 1=-81(LC 10)
Max Upliftl=-96(LC 12), 3= 96(LC 12), 4=-111(LC 12)
Max Gravl=129(LC 17), 3=140(LC 18), 4=250(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-4=-165/269
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150fh L=100ft; eave=l lfh Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 3 except at=lb)
4=111.
7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
20005 Southern Star
T71 Bs1 ns
74497 •
VA
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mirek Industries, Inc. Tue Aug 22 11:42:50 2017 Page 1
I D:04141 DCB7QwRG?h?eJCrfKzY77F-HpGrOc3gluEKOsOpD?ih_W n69FfikW OKXaLkU lylJs3
i-1-7-10 4-5-4 9-6-2 10-6-2
1-7-10 4-5-4 5-0-14 1-0-01.
Scale = 1:24.4
4x6 =
m
0
10 3x6 1 I 3x4 = 9 6 3x6
2x3 11 3 q= I I
2-0-0
2-0-0
4-5-4
2-5-4
7-6-2
3-0-14
9-6-2
2-0-0
Plate Offsets (X,Y)--
(4:0-3-8,Edgel
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.91
Vert(LL)
0.01 5
n/r
120
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.04
Vert(TL)
0.01 5
n/r
90
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.15
Horz(TL)
0.00 7
n/a
n/a
BCDL 10.0
Code FBC2014/FP12007
(Matrix)
Weight: 47lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 BOT CHORD . Rigid ceiling direct(yappiled or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 9-10.
REACTIONS. All bearings 9-6-2.
(lb) - Max Horz 10=149(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 9, 7 except 10= 275(LC 12), 6=-197(LC 12), 8=-117(LC 12)
Max Grav All reactions 250 lb or less at Joint(s) 6, 9, 7 except 10=258(LC 1), 8=263(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-10= 241/718, 2-3=-106/257, 4-6=-184/526
BOT CHORD 6-7=-353/160
WEBS 3-8= 204/414, 4-7=-174/495
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100fh eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for Wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as perANSI/fPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 7 except Qt=lb)
10=275, 6=197, 8=117.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll--7473 rev. 101032015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabdcafion, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
20005 Southern Star
T11891177
74497 `
VB
GABLE
2
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 1.640 S Aug lri zul i Mi I eK industries, Inc. Tug Aug zz i i:42:5i 20i / rage i
I D:04141 DCB7QwRG?h?eJCrfKzY77F-I?qD Dy4nW CMBeOz?niGwWjJOnfy3TzRUmE4H 1 ky1Js2
-1-7-10 4-5.4 9-6-2 10-6-2
1-7-10 4-5-4 5.0-14 1-0-0
4x6 =
Scale = 1:22.8
7 6
3x8 11 2x3 II 5x6 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL)
0.01
5
n/r
120
TCDL 7.0
Lumber DOL
1.25
BC 0.22
Vert(TL)
0.03
5
n/r
90
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.14
Horz(TL)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
(Matrix)
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 7=262/9-6-2, 4=236/9-6-2, 6=346/9-6-2
Max H orz 7=152 (LC 11)
Max U pi I ft7=-283 (LC 12), 4=-213(LC 12), 6= 151(LC 12)
Max Grav7=315(LC 17), 4=236(LC 1), 6=371(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-7=-286/784, 2-3=-192/339, 3-4= 187/294
WEBS 3-6=-241/458
PLATES GRIP
MT20 244/190
Weight: 39lb FT=20%
Structural wood sheathing directly applied or 6-0-0 oc puriins, except
end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/rPi 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 6-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=283,
4=213, 6=151.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED mrTEK REFERANCE PAGE MII-7473 rev. 10/OZ2015 BEFORE USE.
Design valid for use only with MiTek® connectors.lhis design is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricalion, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
city
Ply
20005 Southern Star
T11891178
74497
vC
GABLE
1
1
%
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mrrek Industries, Inc. Tue Aug 22 11:42:52 2017 Page 1
1 D:04141 DCB7QwRG?h?eJCrfKzY77F-DCNbR15PH W U2FAYCKQn93xsZF3LgCQYd_uggZAylJs 1
-1.0-D 5-8-13 11-5-10 12-5-10
1-0.0 5 8-13 5 8-13 1-0-0
5x6 =
10 3x4 = 9 8 7 63x6 II
3x6 11 2x3 11 3x4 =
Scale = 1:26.1
2-2-1
7-1-9
2-2-1
Plate Offsets (),Y)--
f2:0-3-8 Edgel (4:0-3-8 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.48
Vert(LL)
0.01
5
n/r
120
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(TL)
0.01
5
n/r
90
BCLL 0.0 '
Rep Stress Incr NO
WB 0.15
Horz(TL)
0.00
7
n/a
rVa
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
Weight: 53 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP M 30 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
2-9,4-7: 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. All bearings 11-5-10.
(lb) - Max Horz 10=-161(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 9, 7 except 10=-230(LC 12), 6=-230(LC 12), 8=-130(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 10, 6, 9, 7 except 8=303(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-10=-216/575, 2-3=-148/334, 3-4=-131/334, 4-6=-216/579
BOT CHORD 9-10— 416/303, 6-7= 425/185
WEBS 3-8=-227/448, 2-9=-234/483, 4-7=-204/488
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANS)/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
6) Gable studs spaced at 6-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 9, 7 except Qt=lb)
10=230, 6=230, 8=130.
10) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the bullding designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Sireet, Suite 312. Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
20005 Southern Star
T11891779
74497 %
VD
GABLE
1
1
Job Reference (optional)
Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek Industries, Inc. Tue Aug 22 11:42:52 2017 Page 1
ID:04141 DCB7QwRG?h?eJCrfKzY77F-DCNbR15PHW U2FAYCKQng3xsZK3KwCQEd_uggZAylJs 1
i 5-8-13 + 11-5-10
5-8-13 5-8-13
4x4 =
Scale = 1:20.8
I7
a
a 7 s
3x4
3x4 2x3 I I 2x3 I I 2x3 1 1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.48
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.12
Vert(TL)
n/a -
n/a
999
BCLL 0.0
Rep Stress Incr
NO
WB 0.17
Horz(TL)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2014/TPI2007
(Matrix)
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
OTHERS 2x4 SP No.3
PLATES GRIP
MT20 244/190
Weight: 42lb FT=20%
BRACING -
TOP CHORD Structural wood sheathing directly applied orb-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 11-5-10.
(lb) - Max Horz1=-129(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-191(LC 12), 6=-191(LC 12)
Max Grav All reactions 250 lb or less at Joint(s) 1, 5, 7 except 8=286(LC 17), 6=286(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-8=-223/557, 4-6=-223/557
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=24ft; B=150ft; L=100ft; eave=2ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 3-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will
fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atJoint(s) 1, 5, 7 except Qt=lb)
8=191, 6=191.
9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/032015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the appllcablllty of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indlcated,ts to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and 10 prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandricl. VA 22314.
Tampa, FL 33610
Symbols
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ff-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-'/1 d'
X
For 4 x 2 orientation, locate
plates 0-110 from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MTek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(suppprts) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
AN$I/TPI1:
National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89:
Design Standard for Bracing.
BCSI:
Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 1 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2
TOP CHORDS
0
of
O
U
a-
O
f3
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MITek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum.plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
Is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.