Date: July 29th, 2021
ASCE 7 Components & Cladding Wal
Prepared For:
J&G CARPENTRY, INC
7030 SW 16TH COURT
PEMBROKE PINES FL
Project: SEGALLA CONDO DOOR REPLACEMENT
Project Address:
9600 S. OCEAN DR. UNIT 304
JENSEN BEACH Florida
93171 1 44403-6110069445 1 Page 1/1
I Pressure Calculator
0
\0 11111I///,
�� LICE LS+F •.q�
�4.
No PEO 41654193 ; O
/7JO • STATE OF �
"4ORI P • \��
/pNA E�G�` 07/29/
Box for Engineer Seal Only -Original Rqd for Permit & Use
Frank Bennardo, PE FL46549 or Richard Neet, PE FL86488
The following has been considered in determining allowable stress design (ASD) wall opening pressures for the above -
referenced location.
ASCE: ASCE 7-16 (7TH EDN FLORIDA BUILDING CODE, 2020 FBC,
2018 IBC)
Wind Velocity: 170 MPH
Exposure Category: D
Kd: 0.85
Kzt: 1
Minimum Building Dimension: 94FT
Mean Roof Height: 127FT
Unit Elevation: 28FT
ROOF SLOPE: FLAT (<100)
Number Of Openings: 1
Shutter: NO
Mark: 1
Height Of Opening: 80 IN
Width Of Opening: 36 IN
Zone: 4
Based on the above, the following ASD design pressures apply for the
opening marks which shall correspond with contractor -supplied building
layout:
a: 3 FT
Mark: 1
Wall Positive Pressure: 49.2PSF
Wall Negative Pressure:-60.9PSF
M[AN AROF
NDGHTMEM
IK ELEVATION ,Kai
LEAST H00.IZONTAL
DIMENSION
WIND —
FLOW
U \ 4
PLAN VIEW \
COMPLEX 5 5
CORNERS
BUILDINGS> 60' ROOF HEIGHT
�b 10%OF LEAST HORIZONTAL DIMENSION OR 40%OF MEAN ROOF HEIGHT IMRH), WHICHEVER 15 LESS
6UTNOT54%OFLFAST HORIZONTAL DIMENSION OR 9FT. "USE CORNERZONE 5 IFATALL IN QUESTION.
SHUTTER OPTION FORCES OUTPUT TO HEIGHT•HEIGHT/9.
File COP'T
MEAN ROOF
HEIGW(MRH)
U`W.
HFWW
ss
. LTASTHORG
REiI&VECB FOR
CODE COMPLIANCE
STa LCIE BOCC 4l3/zly
Design pressure results are in accordance with the Building & ASCE 7 codes listed above for an ENCLOSED structure only
(Gcpi=+-0.18). Results are based on contractor -supplied data and are not field verified by this office. Input shall be verified
by others prior to permit & use. Selection of all components & their respective approvals shall be by others and are to be
within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a
licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your
openings, visit EngineeringExpress.com/Wind.