Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL EXTERIOR DOORSFlorida Building Code Online BCIS Home Log In ' User Registration I Hot Topics Submit Surcharge ; Stats & Facts Publications Contact Us BCIS Site Map Links Search [7 b Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail zt, +� +t L FL # FL16708-R13 copy 4w: a Application Type Revision ��e p- a Code Version 2020 `73 r g << Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method C JELD-WEN 3737 Lakeport Blvd Klamath Falls, OR 97601 (800) 535-3936 fbcl@jeld-wen.com Rylee Sumner Fricks fbcl@jeld-wen.com REVIEWED FOR CODE COMPLIANCE SU o LCOE COUNTY OJBOCC ql,� JELD-WEN Corporate Customer Service 3737 Lakeport Blvd. Klamath Falls, OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E. Evaluation Report Florida License PE-73778 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2022 Validated By Locke Bowden P.E. Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards 0 Validation Checklist - Hardcopy Received FL16708 R13 COI COI JW SS 2015-04-27.pd Standard TAS 201 TAS 202 TAS 2d3 Year 1994 1994 1994 htip://www.foridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2FlZm6TudWOg6cFU I Gz%2bYuNViQ90 I Ao7zp34bbWg%3d%3d[ 12/16/2020 3:25:39 PM] Florida Building Code Online Certified By Florida Licensed Professional Engineer or Architect FL16708 R13 Equiv 23549-1 Equivalency of ASTM E84-13a and ASTM E84-16.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/03/2020 Date Validated 10/08/2020 Date Pending FBC Approval 10/16/2020 Date Approved 12/15/2020 m6ry of Products--.. - -- FL # ( Model,, Number'or Name ) Description 16708.1 A Design Pro / Smooth Pro / Studio Fiberglass Single (X) Impact Opaque Door 3-0 x 6-8 and 3-0 x 8-0 Inswing and Outswing j Limits of Use a Installation Instructions Approved for use in HVHZ: Yes { FL16708 R13 II 16708.3. SS 2019-10-01 pddf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 { Impact Resistant: Yes Created by Independent Third Party: Yes i Design Pressure: N/A Evaluation Reports Other: �— FL16708 R13 AE PER4663.2 SS 2019-10-Ol.pdf Created by Independent Third Party: Yes 16708.2 I B Design Pro Smoot Pro Fiberglass I Singe X Impact Glazed Door 3-0 x 6-8 an 3-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II 16708.2 SS 2019-10-01.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: —� FL16708 R13 AE PER4438.3 SS 2019-12-13.pdf Created by Independent Third Party: Yes 16708.3 C Design Pro / Smooth Pro / Studio Double (XX) Impact Opaque Door 6-0 x 6-8 and 6-0 x 8-0 Fiberglass Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015727-DP SP OPO LMI HHVZ XO FBC SS { Approved for use outside HVHZ: Yes 2019-12-12.pdf ; Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 { Design Pressure: N/A Created by Independent Third Party: Yes j Other: Evaluation Reports FL16708 R13 AE PER4664.2 SS 2019-10-Ol.pdf Created by Independent Third Party: Yes 16708.4 D Design Pro / Smooth Pro Fiberglass Double (XX) Impact Glazed Door 6-0 x 6-8 and 6-0 x 8-0 j Inswing and Outswing II Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015705 - DP SP GLZ LMI HVHZ XO FBC SS Approved for use outside HVHZ: Yes 2019-12-12.pdf Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4440.2 SS 2019-12-13.pdf / f Created by Independent Third Party: Yes 16708.5 E Design Pro / Smooth Pro / Studio Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Opaque Door Fiberglass 9-0 x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II 16708.5 SS 2019-10-01.pdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports littp://www.floridabuil(ling.orglprlpr_app_dtl.aspx?paramwG EV XQwtDqu8obl%2flZm6Tud W Og6cFU ] Gz%2bYtiNViQ90 ] Ao7zp34bb Wg%3d%.id[ 12/16/2020 3:25:39 PM] Florida Building Code Online Other: FL16708_R13_AE_PER4665.2 SS 2019-10-01.pdf Created by Independent Third Party: Yes 16708.6 — F Design Pro / Smooth Pro Fiberglass Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Glazed Door 9- 0 x 6-8 and 9-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions. W_ _ Approved for use in HVHZ: Yes FL16708 R13 II 16708.6 SS 2019-10-01.pddf, i Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: FL16708 R13 AE P R4442. SS 2019-1 -1 .pdf Created by Independent Third Party: Yes 16708.7 — G Design Pro Smooth Pro Studio Double with sidelite(s) XX,O O,XX/ O XX,O Impact Opaque Fiberglass Limits of Use Door 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015708 - DP SP OPO LMI HVHZ OXXO XXO FBC SS 2019-12-12.Ddf Approved for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4666.2 SS 2019-10-01.12df Created by Independent Third Party: Yes 16708.8 H Design Pro / Smooth Pro Fiberglass Double with sidelite(s) (XX,O/ O,XX/ O,XX,O) Impact Glazed — Door 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16708 R13 II D015709 - DP SP GLZ LMI HVHZ OXXO XXO FQC SS 2019-12-12.pdf Approved for use outside HVHZ: Yes Impact Resistant: Yes Verified By: Hermes F. Norero, P.E. 73778 Design Pressure: N/A Created by Independent Third Party: Yes Other: Evaluation Reports FL16708 R13 AE PER4444.2 SS 2019-12-13.prif Created by Independent Third Party: Yes The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here_. Product Approval Accepts: .. a M � Wreck Credit Card Safe littp:/Avww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2flZtn6TudWOg6cFUlGz%2bYuNViQ9olAo7zp34bbWg%3d%3d[12/16/2020 3:25:39 PM] BUILDING DROPS A Perfect Solution in Every Drop k =y. ., Certificate of Authorization: 29578 April 27, 2015 TO: Whom It May Concern 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com FROM: Hermes F. Norero, P.E. Registered Florida Professional Engineer #73778 MANUFACTURER: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Dear Sir (Madam), To the best of my knowledge, the above -mentioned product conforms to the current edition of the Florida Building Code. Please note that I do not have, nor will I acquire, a financial interest in any company manufacturing or distributing the product(s) for which the reports are being issued. I also do not have, nor will I acquire, any financial interest with the Laboratory that performed the test(s), or with the Engineer witnessing the test(s) and sealing the test report(s). Respectfully submitted, DES o o. 7 T T a ., 0 Cp DP: ••��: .• C= � ��II/III111111, Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2015.04.27 20:14:19-04'00' Hermes F. Norero, P.E. Florida Registered Professional Engineer #73778 Page 1 of 1 NATIONAL CERTIFIED TESTING LABORATORIES s FIVE LEIGH DRIVE YORK, PENNSYLVANIA 17406 TELEPHONE (717) 846-1200 FAX (717) 767-4100 www.nctlinc.com July 30, 2020 Dan Vezo JELD-WEN, Inc. 3737 Lakeport Blvd Klamath Falls, Oregon 97601 RE: Equivalence of ASTM E84-13a and ASTM E84-16 Dear Dan: At your request, I have reviewed an ASTM test method standard to evaluate its equivalence to the test method standard currently referenced by the Florida Building Code. Specifically, I am comparing: ASTM E84-13a Standard Test Method for Surface Burning Characteristics of Building Materials to ASTM E84-16 Standard Test Method for Surface Burning Characteristics of Building Materials. I have reviewed and compared the above -referenced test method standards. Specific changes noted between the standards include: Updated requirements for the photometer measurement system. Added specimen preparation and mounting requirements for flexible fibrous glass insulation used in metal buildings. The noted changes would not cause different test results or different interpretation of the test, and it is my professional opinion that the test method standards are equivalent. Thus, the testing conducted to ASTM E84-13a Standard Test Method for Surface Burning Characteristics of Building Materials is equivalent to ASTM E84-16 Standard .Test Method for Surface Burning Characteristics of Building Materials and, there for,fin compliance with the Florida Building Code, Building, 71" Edition (2020). 61� Joseph A. Reed, P.E. FL PE 58920 FL REG 33474 JAR -.jar cc: 23549-1 Professionals In The Science of Testing EN WINDOWS & DOORS DESIGN PRO/SMOOTH PRO IMPACT APPROVED FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED. ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 A TAS 203.94 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY OR 2X FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE. RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. 4. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. S. 6-PANEL DOOR SHOWN FOR ILLUSTRATION PURPOSES. ADDITIONAL PANEL CONFIGURATIONS AND FLUSH DOORS ARE QUALIFIED. 6. NOTE: AFCO H-497 SILL MEETS WATER INFILTRATION AT WATER TEST PRESSURE (WTP) OF 9.75 PSF. REMAINING SILLS NOT RATED FOR WATER INFILTRATION. IF AUTHORITY HAVING JURISDICTION REQUIRES THAT PRODUCT MEETS THIS REQUIREMENT, PRODUCT SHALL BE USED WHEN INSTALLED AT LOCA71ON PROTECTED BY OVERHANG SUCH THAT OVERHANG (OH) RATIO = OH LENGTH =0H HEIGHT 15>_ 1-0 TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 A TYPICAL ELEVATIONS, DESIGN PRESSURES, AND GENERAL NOTES 2 4 TYPICAL ANCHOR LAYOUTS AND NOTES 3 - OPTIONAL 2X BUCK ANCHORING DETAILS 4 A VERTICAL ASSEMBLIES 5 A HORIZONTAL ASSEMBLIES 6 A WOOD SUBSTRATES 7 A CONCRETE SUBSTRATES 8 A COMPONENTS & BILLOF MATERIALS 371/2" MAX. 6 6 O.A. WIDTH 1 a 2 Z 5 wN� S Q l'Jm V' °D a z 5 E± 0 ACTIVE O Z l7 z §, O 5 OZ = O Z [� TYPE. 3 a 5 6 7 8 9 a a a a a ELEVATION 1 6'-t' DOOP H[WNT 6 5 [2'\ 37 1/2" MAX. O.A. WIDTH 1 Ea w = 1 s a 6 5 ACTIVE d s 0 0 s g / 3 1 5 TYP. ELEVATION 2 1 1 0'- -DDDR HE... NOTE: DOORS SHOWN ABOVE MAY BE LEFT OR RIGHT HAND OPERATING DOORS. MAX. OVERALL DESIGN PRESSURE (PSF) NOMINALSIZE MISSILE CONFIGURATION INSWING OUTSWING IMPACT WIDTH HEIGHT RATING POS. NEG. POS. NEG. X 3'-0" 6'-8" 65• 65 65• 65 LMI&SMI X 3'-0" 8'-0" 50' 50 50• 50 LMI & SMI 'SEE GENERAL NOTE 6, SHEET 1, FOR WATER INFILTRATION APPROVED SILLS. PREPARED BY: BUILDING DROPS, INC. 398 E. DANIA BEACH BWD. 310 DANIA BEACH, FL.33BW IN. 19BAp99 w1e .�.IDSA17aanle WEB: vru.buPaMBaroP o O z l— � c a0 �z O"Jmm c) 0 �[1; N w �4a rrvn� a Z Z mY -Cl O w ti I� O W Q W ~ J w O O J LEI U = ' 1 L7 z a In W a IIq_ a REMARKS BY DATE Add ADAsBLMuId.PDinc Lock GL06/23/1 WeEence DW3. PMIU871A AM 09/16/1 ID 7 SIA OF Y � Reason: 131 approving this documen Date: 2019.1 D.01 21:21:16-04'00' DATE: ni nS 1, GL/TJM I SS/MSS SCALE: NTS DWG. a: nnl 9379E u INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 1/41NCH. SHIM WHERE SPACE OF 1/16INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 4. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING, AND SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 6. FOR 2X STUD CONSTRUCTION, ANCHORING OF THESE PRODUCTS SHALL BE THE SAME AS FOR 2X�BUCK CONCRETE/MASONRY CONSTRUCTION. 7. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD- MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. C. GROUT -FILLED CMU- UNITSTRENGTH CONFORMSTO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AND GROUT CONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 PSI. D. HOLLOW BLOCK CMU - UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI. .8. .SEE SHEETS G-AND_7.EQR_MQREDETAILS..QETHEINSTALLAIIQN.REQUIREMENT$,JNCLUpING ANCHOR.. _..... . _ .... _ . LOCATIONS, EDGE DISTANCES, EMBEOMENTS, AND SHIM SPACING. 9. OPTIONALLY, ANCHORS CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. ANCHORTABLE 6'8" DOORS 8'0" DOORS ANCHOR TYPE ANCHOR S12E SUBSTRATE MIN. EMBEDMENT MIN. EDGE DISTANCE MAX. 0.C_ MAX. D.C. SPACING AT SPACING AT JAMBS JAMBS WOOD SCREW 1J10 2X WOOD BUCK 1-1/2- 3/4" 17-1/2' 17-1/4" OR FRAMING ITW TAPCON 3/16" CONCRETE/CMU 1-1/4' 2-1/2" 17.1/2' 17-1/4" ELCO ULTRACON 1/4" CONCRETE/CMU 1-3/8"-CONC. 1-1/4" - CMU ITW TAPCON 3/16" CONCRETE/CMU 1-1/4' 1" 10" 14-3/8" B2 2. 49 X 2 12" PRE PFH SCREWS DETAIL B2 TYP. HOPPE I. BOTTOM SHOOT MULTI -POINT SHOOT SOLT BOLT PLATE PLATE LOCATION HOPPE R2098931 rat SILLSECTION VIEW 2- 99 X 21/2" PFH SCREWS DETAIL D2 22 23 TYP. HOPPE MULTI -POINT SHOOT BOLT PLATE LOCATION (RH PLATE SHOWN) 02 /[\ HEAD SECTION VIEW ce I zz O �TYP. ANCHOR LAYOUT 6'-9' d 4-D' DOOR HEIGM NOTE: NO ANCHORS REQUIRED AT THE SILL FOR SINGLE DOORS (X) ONLY. PREPARED BY: ' BUILDING DROPS, INC. 3M E. DANIA ist— 9M. ERF M oawa aucn, n 33aos cAx: Isul>�.ar3a wEe: wG.w,bvlat�ed�mr,mm f/1 W 0 3$N$ O Z a ahma �O Opp ZQ wLL„ 5r--� y C a 2 g Zm L2�7 W O 0 U ) Q �c J U Add ADA sill. MuhFPOint Lock GL G/23/14 Reference DWG. RAD10372 AM /16/19 I UIIo o WaxEGEx XI FELRSCAU1CpxD111DRS:eR e 5rt[Mf SIi F[oxortwxSGuk-I�IAUAnON+a oeMTF fROM iXEREpU1REMEMS DETAII[D �[RDx.ALx%x5E0 ENGINEER px ARCND[R SMALL xRVAPE 5(EE SVEUEA: o E p �i N . 7 7 S A _OF r D- DATE: U1.D5.14 DWG. Y: CHK. Y: GCTJM SS MSS SCALE: NTS DWG-R: D01S726 2 PREPARED BY: BUILDING DROPS, INC. /// 19REo4N148CACN0LW.5TEe ll // / Q4NIA READI, F133fd t] PX: 195R1394M]R FA: 19511AT30 .builSn80mpcccm 11 11 INTERIOR EXTERIOR EXTERIOR% INTERIOR 4 f Q 5 INTERIOR ./ EXTERIOR O r o 4 N o Q Do a O ti to m y 1 OPERABLE HEAD �1 OPERABLE SILL 04 OPERABLE SILL a Q a Zx 4 OUTSWING SHOWN •INSWINGSIMILAR 4 INSWING 4 OUTSWING y� U W uj > �c az 11 EXTERIOR '/, INTERIOR ' 7 REMARKS BY OAT INTERIOR EXTERIOR INTERIOR EXTERIOR Add ADA sill, M,Iti.Pti,t L«k GL 06/23 10 / 1 6 '/, Reference DWG. NA0ICS71A AM 09/1E p , doh•. �~ Ns ♦ P aQ e PnfRFiN R NOT RE—A F ! x 1MAACN4 CWIDIttlN3 fOR4SP - rtgt6UU5[iN3T.SQATON TO ory ixOM TXC PFQu�Rln3ENT3 OCT4LC0 XlRFIli 41KFx•. OPERABLE ADA SILL_ OPERABLE SILL OPERABLE SILL 4 INSWING/OUTSWING 4 INSWING 4 OUTSWING N `,'`SLL111IT11E ENDURA HCISO00 OPTIONAL AFCO H-497 * VVI 5 v S10 A OF Q 11 1� T� 9 '!NTERIOR EXTERIOR 8 INTERIOR EXTERIOR o DATE: 02.05.14 GL%TJM SSJMSS g OPERABLE SILL OPERABLE SILL SCALE: NTS 4 OUTSWING 4 OWSWING DWG.N: D015726 SHEET: OF 8 4 INTERIOR —8 - N9 X 2 1/T' PFH EXTERIOR W/ STRIKE HARDWARE 4- MPL STRIKE PLATES n LOCK JAMB J OUTSWING SHOWN - INSWING SIMILAR I 9 - N9 X 13/4" PFH 8-49%21/2"PFH W/HARDWARE W/STRIKEHARDWARE I6'-8"&8'-0"UNITS) 4- MPL STRIKE PLATES EXTEROR INTERIOR 4 MULTI -POINT LOCK JAMB 5 OUTSWING SHOWN -INSWING SIMILAR HINGESCHEDULE DOOR HEIGHT QUANTITY 6'-8" 3 8'-0" 4 HINGE DETAILATIAMB: PLACE N9 X 2-1/2" PFH SCREW NEXFTO W EATHERSTRIP INTERIOR\�• / �O 1-#9%2.1/2"PHILLIPS FLATHEAD WOOD SCREW \' 3- #9 X 3/4" PHILLIPS FLATHEAD WOOD SCREWS EXTMOR' 4-N9 PHI WPS FLATHEAD WOOD SCREWS 17 USE 3/4" LENGTH FOR 6'-B" DOORS USE 1" LENGTH FOR 8'-O" DOORS 3 HINGE JAMB 5 OUTSWING SHOWN - INSWING SIMILAR 3-q8%2"PFH Jr13-N8X 1133/8'PFH(6'-8"UNITS) W/STRIKEHARDWARE/ COME W/HA DW (8'-0"UNITS) 1-MPL STRIKE PLATE COMES W/HARDWARE EXTERIOR INTERIOR MULTI -POINT LOCK JAMB 5 CUTSWING SHOWN -INSWING SIMILAR 4 - #8 X 13/8" PFH 1- REINFORCEMENT PLATE HOPPE N2512296 6 MULTI -POINT LOCK 5 TOP REINFORCEMENT PLATE -ACTIVE PANEL ONLY PREPARED BY: BUILDING DROPS, INC. 198E. DANIA BEACH 8=.ML 3U - DAACMFL1951J3916113 iAM�(9511MA738 wLe:.,w�.e"nn AAaooam� >� O E.,mcN x r O LLJ l/I cC �CL Q my ac U Q Q z, a lD W o w N Occ o O1.4 �z Wa F= REMARKS BY DA- Odd ADA sill, MulbPoint Lock ' GL Gk: ielemncc DWG. PAOIM71A AM 9/11 Im roSTALE OF y DATE: 02.05.14 GLjhM SS/'Ym: s! SCALE: NTS DWG. N: D015726 SHEET: OF 8 5 MIN. EDGE DIST. SEE TABLE SHEET 2 wW x w w 2% W000 BUCK z� ?: N cs ED WOODANCHOR SEE TABLE ON SHEET 2 HEAD (TYPICAL) 6 OUTSWING SHOWN - INSWING SIMILAR 4 OPERABLE SILL 6 OUTSWING- NOANCHOR REQUIRED g OPERABLE SILL 6 OUTSWING- NO ANCHOR REQUIRED t� OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MININIUM EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. 2X WOOD BUCK NN WOODANCHOR L SEE TABLE ON SHEET 2 H SIUCONE % O 0.25' MAX. 2X WOOD BUCK SHIM MIN. EMBED. SEE TABLE SHEET 2 JAMB (TYPICAL) OUTSWING SHOWN - INSWING SIMILAR r OPERABLE SILL INSWING - NO ANCHOR REQUIRED ILICONE SILICONE BUCK zx WOOD BUCK 6 OPERABLE SILL 6 INSWING - NO ANCHOR REQUIRED OPERABLE SILL OUTSWING-NO ANCHOR REQUIRED OPERABLE SILL 6 OUTSWING-NO ANCHOR REQUIRED AFCO H-497 •1: •rr: rfl� OPERABLE ADA SILL 6 INSWING/OUTSWING - NO ANCHOR REQUIRED PREPARED BY: BUILDING DROPS, INC. 39B e. DARIA eEAa etw.. s]F. s]e DANIABFACM, R 13JW �N: (95�)J99BA]B 4:195a)]K.Q)L] wFB......md�c ae�con, C a I__W Ln CL Q. O�in DO 2 a Ln O O O 3 r f— Add ADA 0L Multi -Point Lock GL 06/23) Reference DWG. NA010871A AM 09/16) ' Av m]F 'U xUAFC. AClI:AL�040FFv)KIO4ASPEC OMmF mmnonscnussirFs*.wnoxm BF�� lni ttQInB[MFN*S DeTmtEO MFAF tlu A+ttEN51 FFAG�uFFxrn FBC•uiFR 54.LLVFFesxF Sf.[SIEC•4 a �u wDn `kSill{Itll///j b 5 A OF :SOT P.� � W� • tt' � DATE: 02.05.14 DWG. Y: CHK. Y: GL%TJM I SS/MSS SCALE: NTS DWG. a: D015726 SHEET: OF 8 6 MIN. EDGE DIST. SEE TABLE SHEET 2 F � CONCRETE' w R MASONRY z F BY OTHERS WOOD BUCK (OPTIONAL) CONCRETE ANCHOR SEE TABLE ON SHEET2 1 HEAD (TYPICAL) % OUTSWING SHOWN -INSWING SIMILAR R OTHERSBY • 4 OPERABLE SILL 7 OUTSWING- NO ANCHOR REQUIRED SILICONE •e a • o. CONCRETE/ MASONRY BY OTHERS OPERABLE SILL 7"/ OUTSWING- NO ANCHOR REQUIRED t� OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED. PREPARED BY: ' 1X WOOD BUCK it (OPTIONAL) BUILDING DROPS, INC. 398 E. DANEABEACH BLVD..PUM i a w DMIA MAp, FL imm i0 '•i %%% CONCRETE ANCHOR SILICONE M19 13-9•)B SEETABLE ON SHEET2 F. L9Eapu.ane WEB: vwv.0u�tln(Nocaian • '• 1' CONCRETE/ m "�• MASONRY o BY OTHERS • 'J'•• %% a O W o h m ud —4— MAX. O C ^ n SHIM a 1• CONCRETE/MASONRY BY OTHERS ¢ my MIN. EMBED.Ln SEE TABLE SHEET2Lu a C r2 JAMB (TYPICAL) OPERABLE SILL w W� OUTSWING SHOWN - INSWING SIMILAR 7 INSWING- NO ANCHOR REQUIRED p U� Z p SILICONE R SILICONE i REMARKS BY DATE =MASONRY ° ° Add ADA sill, Multl-0oint Lock GL 6/23/: CONCRETE/ --1 ' CONCRETE/ Reference DWG. OA030873A AM 09/16/: MASONRY BY OTHERS BY OTHERS nnuu roRO N xor REn9n •Rwl conortaniiDRA sREEn frtF.NE LTE COxon�OM CRUE 6 OPERABLE SILL T� OPERABLE SILL EIG "`SE= °�°`°"p` 1S.",C ' EEM MfR DR •RCHR[R Sx"tl ARFAUESrtERRECG'K INSWING -NO ANCHOR REQUIRED OUTSWING-NOANCHORREQUIRED `,\\\IAIIIJJ/I2Y2 T AFCO H-491 �* N.77 S A ' SILICONE SILICONE � � OF 4 � i Ofi O IOC' •' • w' a ° ° o ° F.a�° b b��e • CONCRETE/ CONCRETE/ MASONRY MASONRY BY OTHERS BY OTHERS g OPERABLE SILL / OPERABLE SILL DATE: 02.05.14 OUTSWING- NO ANCHOR REQUIRED 7 UTSWING/INSWING- NO ANCHOR REQUIRED DWG. V: CHK. Y: GL JM I SS MSS SCALE: NTS DWG.N: D015726 7 BILL OF MATERIALS ITEM# DESCRIPTION MATERIAL 1 FRAME HEAD/JAMBS FINGER -JOINTED PINE SOLID PINE LAMINATED VENEER LUMBER COMPOSITE 2 (NOT USED) 3 (NOT USED) 4 THRESHOLD '- 5 THRESHOLD - 6 THRESHOLD - 7 AFCO H-497 THRESHOLD - 8 THRESHOLD - 9 THRESHOLD - 10 ADA THRESHOLD - 11 WEATHERSTRIP URETHANE FOAM & POLYETHYLENE 12 NON -COMPRESSION SHIM (0.25" MAX. THK.) COMPOSITE 13 (NOT USED) - 14 (NOT USED) - 15 #10 WOOD INSTALLATION SCREW W/11/2- MIN. EMBEDMENT STEEL 16 CONC/CMU ANCHOR (SEE ANCHOR TABLE SHEETS 2 & 3) STEEL 17 BUTT HINGE (SEE SCHEDULE SHEET 5) STEEL 18 LOCK SERIES 400 STEEL 19 DEADBOLT SERIES 790 STEEL 20 ROCKWELL MULTI -POINT TONGUE LATCH If 732287686-8 UNIT ROCKWELL MULTI -POINT TONGUE LATCH 473228790 8-0 UNIT STEEL 21 HOPPE MULI-POINT HARDWARE HLS9000 STEEL 22 HOPPE MULI-POINT H EAD SHOOT BOLT PLATE LH 48784091 STEEL 23 HOPPE MULI-POINT HEAD SHOOT BOLT PLATE RH#8783923 STEEL 20 ROCKWELL MULT-POINT LOCK O O O 21 HOPPE MULT-POINT LOCK W/ SILL SHOOT BOLT PLATE #2098911 hm 0 " PREPARED BY: IQY BUILDING DROPS, INC. 393 E. DANIA 6EA(9181W. SEE 336 DANIA.EAs:N.fLs— FAX:99739 AI %:19 WE9: w�v.Eu...ibFB.. Nmm �oq p F Tors` . 4 Q o m p OD c LL O � o O CO x hj�1 w N F- r' Z uj ^' z Wi O � V REMARKS BY DA sdd ADA sill, M09-Ponuck s L GL 612: Reference 01 DC RA030871A AM 09fl I 9a�ax6�hnecis i'iLiE+is,.x�ivn sttaiK uuex*s �a"usewnx.xrs oacureENr. ```LTLnnlurry� c Ul pop�� Nc .79" e -41.605"L—I p fl S OFRAME HEAD/JAMBS O THRESHOLD O THRESHOLD O THRESHOLD 22 HEAD SHOOT BOLT PLATE (LH) :0 VARIES, SEE BOM AT LEFT �i} L_ i .er%Err2 . i I- �-- 4.563" 4.66° --{ 5.62' 4,57' --{ ( 1.75" DATE: 02 DWY: G. O AFCO H-497 THRESHOLD O THRESHOLD THRESHOLD O THRESHOLD ADA O HEAD SHOOT BOLT PLATE (RH) GL/TJM 7 8 9 10 23 SCAL O E; DWG. #: p o - ( SHEET: 458' --I I I N 5.�' I�I ' I--- 4.62" � � Y-- 4.56" I c 1.75" u®® III A OF p3L FA 35 �A .05.14 CHK. Y: SS%MSS 015726 OF8 8 119,,\\,BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Product az1c-n of JELD-WEN, inc. Design Pro / Smooth Pro Opaque (Impact) (HVHZ) for Florida Product Approval 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Current Florida Building Code Method: 1— D (Engineering Method) Category: Exterior Door Assemblies Sub — Category: Swinging Exterior Door Assemblies Product: Design Pro/ Smooth Pro Material: Fiberglass Product Dimensions: 3'-0" W x 6'-8" H (Nominal) 3'-0" W x 8'-0" H (Nominal) Prepared for: .IELD-WEN, inn 3737Lake!;p�.v't Nvd. Klarnao%h alsa OR976."k Prepared by: .Hermes F. Norero .:1Ea Florida Professional Engineer # 73778 Date: 09/13/2019 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2019.10.01 21:18:24-04'00' `````,0�1111111I'SS E s ' •. �o N .7 7 "o S A �.� OF 'gym 0 t -Z' HerF1No►R E. Florida No. 73778 BUILDING DROPS a' t A Perfect Solution in Eve Drop! Every P• Y= Certificate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: Product Name: JELD-WEN, Inc. Exterior Door Swinging Exterior Door Assemblies State Product Approval Method (1)(d) Design Pro / Smooth Pro Opaque (Impact) (HVHZ). 3'-0" X 6'-8" (Nominal) 3'-0" X 8'-0" (Nominal) Date: 09/13/2019 Report No: 4663.2 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions provided by manufacturer for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering for Wind Zone 3. 4. Site conditions that deviate from the details of manufacturer require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions for size and design pressure limitations Hermes F Norero, P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS i Date: 09/13/2019 { A Perfect Solution in Every Drop! Report No: 4663.2 Certificate of Authorization: 29578 Certification Agency: The manufacturer has demonstrated compliance of door products in accordance with the current Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization #: CER1773) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: NCTL-210-3916-01 08/30/13 NCTL-210-3925-03 02/07/14 NCTL-210-3916-02 w/ addendum 06/10/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 TAS Report Engineer of Record: Gerard J. Ferrara, P.E. Report # Report Date: SJW2013-194 w/ addendum 06/10/14 TAS Report Engineer of Record: Kevin P. Tyra, P.E. Report # Report Date: SJ W 2013-196-TAS 09/13/13 SJW2013-246 12/17/13 SJW2013-251 12/23/13 SJ W 2013-252 12/23/13 SJW2013-253 12/23/13 S1 W 2014-032 04/22/14 SJW2014-073 06/26/14 S1 W 2014-077 06/27/14 SJW2014-072 06/27/14 SJW2014-080 07/03/14 TAS Report Engineer of Record: Robert H. Zeiders, P.E. 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization #QUA1789) Hermes F Norero, P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS 3' A Perfect Solution in Every Dropt '. Certificate of Authorization: 29578 Date: 09/13/2019 Report No: 4663.2 3. Component Material Testing of Dylite Expandable Polystyrene by Intertek Testing Services NA, Inc. ASTM E84 Report#: 3113726SAT-001 R1 Report Date: 03/13/09 4. Component Material Testing of Fiberglass SMC Skin Element Materials Technology ASTM D635, ASTM D638, ASTM D1929, ASTM D2843, ASTM G155 Report#: ESP010982P Report Date: 02/26/13 Installation: Refer to Installation Instructions (D015726) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to drawing (13015726) for pressure information. Hermes F Norero, P.E. Florida No.73778 Page 4 of 4