Loading...
HomeMy WebLinkAboutProduct Approval; Roofing UnderlaymentsF le cop'JW u . UE ad BCIS Home I Log In + User Registration i Hot Topics subm(t r g 1� P b'c io s •Contact Us Ii BCIS Site Map I Links I Search` ') (Z,L- a bo pL n6i Product Approval ST. L C�E CO �Y ley, - - USER: Public User U / 1V/t\)JII B O q Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL10450-R14 — - - Revision 2020 Approved AUG 31 2021 ST. Lucie County, Permitting Tarco Roofing One Information Way Suite 225 Little Rock, AR 72202 (254) 913-7750 smohseen@tarcoroofing.com Shaik Mohseen smohseen@tarcoroofing.com Shaik Mohseen 2403 Taylors Valley Road Belton, TX 76513 (254) 913-7750 smohseen@tarcoroofing.com Shaik Mohseen 2403 Taylors Valley Road Belton, TX 78717 (254) 939-3775 Ext210 smohseen@tarcoroofing.com Roofing Underlayments PS200 HT Ice & WaterArmour Page 4 Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C3 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report .Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/26/2022 Validated By John W. Knezevich, PE C3 Validation Checklist - Hardcopy Received Certificate of Independence FL10450 R14 COI 2021 01 COI NIEMINEN.Pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D3909 2014 ASTM D4533 2015 ASTM D4798 2011 ASTM D4869 2016 ASTM D5035 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products r i ASTM D6164 ASTM D6380 FM 4474 FRSA/TRI Sixth Edition Method 1 Option D 03/22/2021 03/29/2021 04/06/2021 06/08/2021 2011 2013 2011 2018 Model, Number or Name Description 10 550.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies se Installation Instructions Approved for use in HVHZ: No FL10450 R14 II 2021 03 22 FINAL ER TARCO UNDERLAYMENTS FL10450- 9"a Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party: Yes Other: 1.) The design pressure herein pertains to one particular bonded Evaluation Reports .: i FL10450 R14 AE 2021 03 22 FINAL ER TARCO UNDERLAYMENTS FL10450- R14.p_df underlayment application for use beneath adhesive -set tile systems. Refer to ER Section Created by Independent Third Party: Yes 5.6.2 for details, and other bonded underlayment systems. 2.) Refer to ER Section 5 for Limits of Use. Back Plea; Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have anyiquestions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails. provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here. Product Approval Accepts: ®Wiwi F R Credit Card Safe NEMO Ietc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, Cr 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 (254) 913-7750 Evaluation Report 10880.07.08-1114 FL10450-1114 Date of Issuance: 07/11/2008 Revision 14: 03/22/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as•the named prod u 1r�s t rsferenced Quality Assurance or production facility location(s) changes, or Code provisions that relaAto t e pro uct s) ,change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEIVIOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the! request of the Building Official. This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCAANE1983 Nieminen, P.E. on 03/22/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen; P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC I O-NEMOletc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Tarco Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 7t' Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject .to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: ,Section _ . _.. _. __,.. ._ _-Pro a .._ ..,. _Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1 / R905.1.1 Material standard ASTM D226 2009 1507.1.1 / R905.1.1 Material standard ASTM D4869 2016 1507.1.1, 1501.2.4, 1507.2.9.2 / R905.1.1, Material standard ASTM D1970 2015 R905.2.8.2 1507.2.9.2, 1507.6.5 / R905.2.8.2, R905.5.4 Material standard ASTM D3909 2014 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tear strength ASTM D4533 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tensile strength ASTM D5035 2011 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission' ASTM D4869 2016 1507.2.9.2, 1507.6.5 / R905.2.8.2, R905.5.4 Material standard ASTM D6380 2013 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2 / R905.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering, ASTM D4798 2011 3. REFERENCES: Entj Examination Reference Date Enti Examination Reference Date ERD (TST6049) D4869, D5035 C30280.12.09 12/11/2009 PRI (TST5878) ASTM D226 TOT-014-02-02 05/18/2004 ERD (TST6049) FRSA/TRI T33190.08.30 08/06/2010 PRI (TST5878) ASTM D226 TOT-015-02-02 05/24/2004 ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010 PRI (TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 ERD (TST6049) ASTM D4798 C30280.12.09-R2 08/20/2010 PRI (TST5878) ASTM D4869 TOT-009-02-02 09/14/2004 ERD (TST6049) FM 4474 T37610.07.11 06/29/2011 PRI (TST5878) ASTM D226 TOT-041-02-01 05/24/2006 ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012 M-D (CER1592) ,. FBC HVHZ 16-1116.09 01/12/2017 ERD (TST6049) ASTM D6380 T40790.04.12 04/06/2012 NEW FBC Cross -List Listing Agreement 01/20/2020 ERD (TST6049) ASTM D6164 T35410.04.12 04/18/2012 NEMO FBC Cross -List 2 Listing Agreement 2 03/22/2021 ERD (TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 NEMO (TST6049) • FRSA/TRI TAR-SC8020.06.18 06/05/2018 ERD (TST6049) FRSA/TRI T43930.09.13-R2 09/11/2013 NEMO (TST6049) Tensile adhesion 4S-TAR-18-002.07.18-1 07/20/2018 ERD (TST6049) D226 & D4869 SC4950.02.14-R2 06/25/2014 TST6049) NEW (TST6049)-. FRSA/TRI 4S-TAR-18-002.07.18-2 07/20/2018 ERD (TST6049) ASTM D1970 TAR-SC9480.15 07/02/2015 NEMO (TST6049) TAS 117(13) 4i-CTR-I9-SSCRT-01.A 04/10/2019 ERD (TST6049) FM 4474 TAR-SC8020.14 12/03/2015 NEMO (TST6049) ASTM D4798 4i-TAR-I9-SSUDL.01.A 08/27/2019 ERD (TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 NEMO (TST6049) ASTM D1970 4j-TAR-20-SSUDL-02.A 02/08/2021 ERD (TST6049) FM 4474 T6460.06.07-R2 05/26/2017 NEMO (TST6049) ASTM D5035 4j-TAR-20-SSUDL-02.A 02/22/2021 ERD (TST6049) ASTM D226 TAR-SC33965.02.17-R1 05/17/2017 NEMO (TST6049) ASTM D1623/D4798 41-TAR-20-SSUDL-03 03/15/2021 ERD (TST6049) FBC 1507.1.1 TAR-SC16115.17 10/02/2017 Tarco Roofing Adhesive comp Affidavit 12/15/2015 ERD (TST6049) FRSA/TRI TAR-SC16115.17 10/02/2017 UL, LLC. (QUA9625) QA Service Confirm (IND) 11/22/2016 ERD (TST6049) ASTM D4533 CTR-SC16080.10.17 10/25/2017 UL, LLC. (QUA9625) QA Service Confirm (PA) 06/28/2017 PRI (TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 UL, LLC. (QUA9625) QA Service Confirm (Tx) 08/13/2018 PRI (TST5878) ASTM D1970 13RY-017-02-01 08/11/2003 UL, LLC. (QUA9625) QA Florida BCIS Current NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate ofAuthorization #32455 77H EDITION (2020) FBC NOW-HVHZ EVALUATION FL10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 2 of 11 ONEMOletc. PRODUCT4. Product Material Standard Plant(s) Description 4.1 LeakBarrier° MS300 Ice and ASTM D1970 Belton, TX self -adhering, glass mat reinforced, mineral Water Armor Greencastle, PA surfaced, SBS modified roof underlayment 4.2 SRS Distribution TopShield ASTM D1970 Belton, TX •, self -adhering, glass mat reinforced, mineral e & Water G300 ILeakBarrier' Greencastle, PA surfaced, SBS modified roof underlayment 4.3 PS200"T Ice and ASTM D1970 and Belton, TX ' self -adhering, glass mat reinforced, fabric ater Armor FRSA/TRI 09-18 Greencastle, PA surfaced, SBS modified roof underlayment 4.4 LeakBarrier° PS200mu Ice ASTM D1970 Belton, TX self -adhering, glass mat reinforced, smooth and Water Armor Greencastle, PA poly film surfaced, SBS modified roof underlayment 4.5 LeakBarrier' NR600 Ultra Ice ASTM D1970 and Greencastle, PA self -adhering, polyester -fabric surfaced, SBS and Water Armor FRSA/TRI 09-18 modified roof underlayment 4.6 LeakBarrier SS400 Ice and ASTM D1970 Belton, TX self -adhering, fiberglass reinforced, smooth Water Armor Greencastle, PA surfaced modified underlayment 4.7 Tarco 30 ASTM D226, Type II Belton, TX asphalt -saturated organic felt Greencastle;. PA 4.8 LeakBarrier° EasyLay' ASTM D226, Type II Belton, TX asphalt -coated polyester fabric roof Greencastle, PA underlayment 4.9 Fiberglass Mineral Surfaced ASTM D3909 Greencastle, PA glass -fiber -reinforced, asphalt -coated, granule Roll Roofing surfaced underlayment used as a valley liner 4.10 ASTM Organic Mineral ASTM D6380, Class M Greencastle,'PA asphalt -saturated organic roll roofing sheet Surface Tile Underlayment 4.11 LeakBarrier EasyMopl SBS FRSA/TRI April 09-18 Greencastle, PA polyester reinforced, SBS modified bitumen roofing underlayment 4.12 LeakBarrier EasyLay' UDL 1507.1.1.1(2&3, Gujarat, India woven -polymeric scrim with a textured fabric 15 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) 4.13 SRS Distribution TopShield® 1507.1.1.1(2&3, Gujarat, India. woven -polymeric scrim with a textured fabric EL30 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) 4.14 LeakBarrier° EasyLay' UDL 1507.1.1.1(2&3, Gujarat, India woven -polymeric scrim with a textured fabric 30 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority. Having Jurisdiction. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 3 of 11 ONEMO I etc. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF VVER OPTIONS Asphalt Clay and Concrete Tile Metal L Slate or Wood Underlayment Shingles (1507.3) Slate -Type Mechanical Adhesive- Panels lhingleip Shingles Shakes (1507.9) . (1507.2) Shingles Attach Set (1507.4) SSOZS) , (1507.7) (1507.8) Yes Yes LeakBarrier M5300 Yes No No No No Yes (joint strips, 1507.1.1.3 (joint strips, 1507.1.1.3 R905.1.1.3) / R905.1.1.3) TopShield Ice & Water Yes Yes G300 Yes No No No No, Yes Goint strips, 1507.1.1.3 ()pint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) Yes Yes s Yes Yes LeakBarrierP5200HT Yes Yes See5.6.1 (No copperor (No pper Yes Gointstrips, 1507.1.1.3 Gointstrips, 1507.1.1.3 zinc) o inc) / R905.1.1.3) / R905.1.1.3) Yes. Yes Yes LeakBarderPS200mu Yes No No' (N0 (No copper Yes Gointstrips, 1507.1.1.3 Golntstrips, 1507.1.1.3 copperor zinc) orzinc) /R905.1.1.3) /R905.1.1.3) Yes Yes Yes Yes Yes LeakBarrier NR600 Ultra Yes Yes See 5.6.1 (No (No.copper Yes Goint strips, 1507.1.1.3 Goinfstrips, 1507.1.1.3 copperor zinc) orzinc) / R905.1.1.3) / R905.1.1.3) Yes Yes LeakBarderSS400 Yes No No No No Yes Goint strips, 1507.1.1.3 Goint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) LeakBarrier EasyLay Yes Yes Yes No No Yes No No See 5.6.2 See 5.6.2 LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay Yes Yes Yes Yes Yes Yes No No UDL 30 See 5.6.2 See 5.6.2 TopShield EL30 Yes Yes Yes Yes Yes Yes No No See 5.6.2 See 5.6.2 Tarco 30 Yes Yes Yes Yes Yes Yes Yes Yes See 5.6.2 See 5.6.2 Fiberglass Mineral Yes Surfaced Roll Roofing (Valley No No No No No No No Liner) ASTM Organic Mineral Yes Yes Yes Surface Tile (Valley (Cap Sheet in (Cap Sheet in No No No No No Underlayment Liner) 2-ply system) 2-ply system) See 5.6.1 Yes Yes LeakBarrier EasyMop SBS No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) , See 5.6.1 NEMO ETC, LLC Certificate ofAathorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Tarco Roof Underlayments; (254) 913-7750 Evaluation Report 10880.07.08-1114 FL Revision 14: /22/2021 age 4of11 O.MEMO etc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LeakBarrier PS200HT Dupont "Tile Bond— Roof Tile Adhesive" FL22525 LeakBarrier PS200HTI LeakBarrier NR600 Ultra, ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS ICP Adhesives and Sealants "Polyset® AH-160" FL6332 LeakBarrier PS200HT ICP Adhesives and Sealants "Polyset® RTA-1" FL6276 5.6.2 Tarco 30, EasyLay, LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 may be used as a mechanically attached anchor sheet followed by an asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS. 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlaymerit Application Primer Substrates LeakBarrier MS300 self -adhering (Optional) , ASTM D41 plywood; OSB or structural concrete TopShield Ice & Water G300 LeakBarrier PS200HT LeakBarrier PS200mu LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier MS300 self -adhering none ASTM D226 Type II felt; ASTM D4869 Type III or IV felt; LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 TopShield Ice & Water G300 LeakBarrier PS200HT LeakBarrier PS200Mu LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier MS300 .self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) TopShield Ice & Water G300 LeakBarrier PS200HT LeakBarrier PS200Mu LeakBarrier NR600 Ultra LeakBarrier SS400 ASTM Organic Mineral Surface Tile Underlayment hot asphalt ASTM D41' structural concrete LeakBarrier EasyMop SBS ASTM Organic Mineral Surface Tile Underlayment hot asphalt None ASTM D226 Type II felt, ASTM D4601 base sheet LeakBarrier EasyMop SBS I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 10880.07.08-R14 Certificate of Authorization U32455 TRH EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-1134 Tarco Roof Underlayments; (2S4) 913-7750 Revision 14: 03/22/2021 Page 5 of 11 ONEmoletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but - for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but -.for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift. limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile.lnstallation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and,reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1564.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure forthe selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -75.0 6 : Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200ml, self -adhered. Underlayment: LeakBarrier PS2001T, self -adhered. #2 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200m' or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200ml, self -adhered Underlayment: LeakBarrier PS200HT, Self -adhered. #3 Maximum Design Pressure = -217.5 psf: Deck: - Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200"T, self -adhered. #4 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate ojAuthoriration #32455 77H EDITION (2020) FBC NON-HVHZ EVALUATION FL30450-1134 Tarco Roof Underlayments; (254) 913-7750, Revision 14: 03/22/2021 Page 6 of 11 0_.NEM0 etc. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,.Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #5 Maximum Design Pressure = -45.0 Dsf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter.annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at.the 4-inch wide side laps and 8" o.c. at -three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS20011, self -adhered. #6 Maximum Design Pressure = -45.0 Dsf*: Deck:- Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch- head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Primer: ASTM D41 primer at tin -caps. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier NR600 Ultra, self -adhered. #7 Maximum Design Pressure = -60.0 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3).equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment:, LeakBarrier PS20011, self -adhered. #8 Maximum Design Pressure = -60.0 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular, ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS20011, self -adhered. NEW ETC, LLC Evaluation Report 10880.07.08-Ri4 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.30450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 7 of 11 O-NEMOletc. #9 Maximum Design Pressure = -60.0 nsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-6/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Primer: ASTM D41 primer at tin -caps. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier NR600 Ultra, self -adhered and back nailed using 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps spaced 12" o.c. within the self -adhering side laps. #10 Maximum Design Pressure = -82.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at'four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200m', self -adhered Underlayment: LeakBarrier P5200"T, self -adhered. #11 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200m', self -adhered 'Underlayment: LeakBarrier PS200HI, self -adhered. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment, Prepared Roof Cover Installation Type Maximum Exposure (days) LeakBarrier PS200"T, or ASTM Organic Mineral Surface Tile Underlayment Adhesive -set tile roof system or mechanically attached 180 LeakBarrier NR600 Ultra or LeakBarrier EasyMop SBS Mechanically attached 180 LeakBarrier EasyLay Mechanically attached 180 LeakBarrier EasyLay UDL 30 Mechanically attached 180 LeakBarrier NR600 Ultra or LeakBarrier EasyMop SBS Adhesive -set tile roof system 30 LeakBarrier MS300, PS200mu, SS400 or TopShield Ice & Water G300 Mechanically attached 30 LeakBarrier EasyLay UDL 15 or TopShield EL30 Mechanically attached 30 Tarco 30 Mechanically attached 1 NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVH2 EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 8 of 11 NEnMO etc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only )be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS'FOR DIRECT -DECK TILE INSTALLATIONS Underlayment* Tile Profile Staging Method Maximum Slope LeakBarrier PS200Hr Flat 10-tile stack** or 6,tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 6:12 LeakBarrier NR600 Ultra Flat or Lugged 6-tile stack (4 over 2) 6:12 ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 6:12 Notes: *Tarco Roofing specifies a minimum 48 cure -time after the installation of self -adhering membranes and before loading of roofing tiles. **If tiles are to be left in a staged condition for more than 30 days, Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to slope, regardless of the allowances noted above 6. • • 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tarco 30: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Tile Applications: s Tarco 30 is limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC.Approved hot -asphalt applied cap sheet. Refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements. 6.4 LeakBarrier EasyLayc 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. ; FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Evaluation Report 10880.07.08-Ri4 Certificate afAuthariration #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-R14 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 9 of 11 O.NEMOjetc. 6.4.2 Tile Applications: LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition • When LeakBarrier EasyLay is followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC Approved hot -asphalt applied cap sheet, refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements. • When LeakBarrier EasyLay is followed by LeakBarrier PS20011, •refer to Section 5.8.3.2 herein for attachment requirements. 6.5 LeakBarrier EasyLay UDL 15, TopSh(eld EL30 or LeakBarrier EasyLay UDL 30: 6.5.1 Non -Tile Applications: Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) forthe type of prepared roof covering to be installed; and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.2 Tile Applications: LeakBarrier EasyLay UDL 15, TopShield EL30 and LeakBarrier EasyLay UDL 30 are limited to use as a mechanically attached base sheet in the `TWO-PLY SYSTEM" from FRSA/TRI.•Florida High Wind Concrete and Clay Roof Tile Installation Manual; Sixth Edition, followed by LeakBarrier PS2001T, self -adhered. Refer to Section 5.8.3.2 herein for attachment requirements. 6.6 LeakBarrier® MS300, LeakBarrier® PS2001u, LeakBarrier® SS40Q Ice and Water Armor or TopShield Ice & Water G300: 6.6.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869, Type III or IV felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.6.2 Multi -Ply Underlayment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. 6.7 LeakBarrier® PS200HT or LeakBarrier® NR600 Ultra: 6.7.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869, Type III or IV felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.7.2 Tile Applications: Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. REMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorization &32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.30450-1114 Tarco Roof Underlayments, (254) 913-7750 Revision 14: 03/22/2021 Page 10 of 11 MEMO I etc. 6.9 ASTM Organic. Mineral Surface Tile Underlayrrient and LeakBarrierlm EasyMop SBS: 6.8.1 Tile Applications: ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier m EasyMop SBS are limited to use as the Hot Asphalt applied "Cap Sheet" in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.9 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral, Surface Tile Underlayment: 6.9.1 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment are limited to use as a valley liner in. accordance with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance with the manufacturer's instructions before applying shingles. REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. ASSURANCE9. QUALITY UL LLC— QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEIVIO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-R14 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 11 of 11