Loading...
HomeMy WebLinkAboutRoofing Sheet ApplicationC jille COPY, (0"4T. LUCIE WORKS ill WEED 'FU ST LUCIE COUN�Y9NEPLIAhICE T TION SHEET STr Lu i Florida Building �qqiliti6..'n-((2020) AUG 3 ®202i I Based on Section 1525 of the Florida Building Code - Building ST. Lucie Co 1 INSTRUCTION PAGE county, Permitt+n,g COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2A,4,5,6;7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 1,2,3,4,5,6;T Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form:RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: 'Roof Doctors LLC License # CCC1326620 Job Address 1713 Ponce De Leon Prado ROOF CATEGORY 0 Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles iWetal Panel/Shingles Mood Shingles/Shakes 0 New roof 13 Repair Low Slope Roof Area (SF) 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE- D Maintenance A Reroofing -ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 1731 0 Recovering Total (SF) 1731 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Metal Alliance Inc. Notice of Acceptance Number: FL29523-R1 (29523.2) Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): —277, one 1: 206 Zone 2e: 206 Zone 2n:206 Zone 2r: 206 Zone 3e: 206 Zone 3r: 206 . Method A - - 206 Deck Type: \Typendelaent: Tarco -RoofingpS20.0 HT Ice & Water Armour, spif adhered Roof Slope: _1 : 12 na rrier: na RidgeVnailation?tener Type & Spacing: Self - Adhered Adhesive Type: na Type Cap Sheep na Mean RooPHeidht: _ 9 ! Roof Covering: 100SL 1" Nailstrip 24ga Type & Sipe Drip 24 ga Edge: