BLOWER DOOR TEST FORM
House Infiltration Test Certification,
Prescriptive and Performance Method
Date: I. (C 1 (1_0 `L k --
Contractor:
Job Address
Permit ##:
Construction: ( (/f New Construction -- Complete ( ) Existing —After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = _ T1 �1 Test Date:.
Volume
ACH (50) = CFM (50) x 60 / Volume = 3 ` M hanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less ( Pass ( )Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in C{imate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.1-05 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the l=lorido Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3,
Testing Company
Company Name: Pro -DUCE Services
Address:
1915 Rio Vista Drive, Ft. Pierce, FL 34949
i hereby certify that the above House infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1..2 Climate Zone 2.
Signature: -`
Printed name: Martin Klein
License/Certification #: 5061633
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34)82
772-462-2165 Fax 772.4.62-6443
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
Date: C kz�'L_t � f Permit #: _
Contractor: [ Y i{ A w `
Construction: �Klost Construction Test
v 06 -U.�'f
Lot #:
Address: 7— � 3 —' 6 - a uiC �^G
n Rough -in Test
Test Conditions: �l
Date: l t 2�11 Floor Area (ft2):
Time: _ �� y Primary Location of Supply Ductwork G
Indoor F Temperature : _1 3 p � � Primary Location of Return Ductwork
Outdoor Temperature (F): S5
Total Leaks a Test Outside
Duct Leakage: Default ❑ Prop. Leak Free ❑ Proposed On
Test Pressure: j (Pa)
Baseline Duct Pressure (optional) 0 _ (Pa)
Duct Press. (Pa)
Flow Ring
Installed
Fan Press
Pa
Flow (cfm)
Testing Company
Resutts1->r1Pass 0 Fail
Total Leakage (cfm): ��6
Total Leakage per 100 sgft: - ; ;, " 'j_ e:) ZIP
CFM25 x 100 divided by the CFA = Duct Leakage CFM1100 sgft.
Company Name: Pro -Duct Services Address:
I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 51' Edition FBC Energy Conservation requirements in accordance with
Section R403.2.2.
Signature:
Printed Name: Martin Klein License/Certificate #: 5061633
BUILDING PERFORMANCE INSTITUTE, INC
iQ7 Hermes Road. Suite 210
Malta NY 12020
(877) 274-1274 S
WwIN bpI Ofg
Martin Klein
PI BPI IN: 5061633
:- FRTI# iFD P
(SEE KVENSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
Infiltration & Duct Leakage 4126l2D24