HomeMy WebLinkAboutBlower door.Duct leakage test, 9.17.21�L . a..BY Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fart Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification, Prescriptive and Performance Method Date: I. (C 1 (1_0 `L k -- Contractor: Job Address Permit ##: Construction: ( (/f New Construction -- Complete ( ) Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = _ T1 �1 Test Date:. Volume ACH (50) = CFM (50) x 60 / Volume = 3 ` M hanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less ( Pass ( )Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in C{imate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.1-05 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the l=lorido Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3, Testing Company Company Name: Pro -DUCE Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949 i hereby certify that the above House infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1..2 Climate Zone 2. Signature: -` Printed name: Martin Klein License/Certification #: 5061633 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34)82 772-462-2165 Fax 772.4.62-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: C kz�'L_t � f Permit #: _ Contractor: [ Y i{ A w ` Construction: �Klost Construction Test v 06 -U.�'f Lot #: Address: 7— � 3 —' 6 - a uiC �^G n Rough -in Test Test Conditions: �l Date: l t 2�11 Floor Area (ft2): Time: _ �� y Primary Location of Supply Ductwork G Indoor F Temperature : _1 3 p � � Primary Location of Return Ductwork Outdoor Temperature (F): S5 Total Leaks a Test Outside Duct Leakage: Default ❑ Prop. Leak Free ❑ Proposed On Test Pressure: j (Pa) Baseline Duct Pressure (optional) 0 _ (Pa) Duct Press. (Pa) Flow Ring Installed Fan Press Pa Flow (cfm) Testing Company Resutts1->r1Pass 0 Fail Total Leakage (cfm): ��6 Total Leakage per 100 sgft: - ; ;, " 'j_ e:) ZIP CFM25 x 100 divided by the CFA = Duct Leakage CFM1100 sgft. Company Name: Pro -Duct Services Address: I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 51' Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Martin Klein License/Certificate #: 5061633 BUILDING PERFORMANCE INSTITUTE, INC iQ7 Hermes Road. Suite 210 Malta NY 12020 (877) 274-1274 S WwIN bpI Ofg Martin Klein PI BPI IN: 5061633 :- FRTI# iFD P (SEE KVENSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltration & Duct Leakage 4126l2D24 BUILDING PERFORMANCE INSTITUTE, INC