HomeMy WebLinkAboutEngineering, density report "v c)gl
THoM S
gt,Peim�\n0
EOTECHNICAL SERVICES
REPORT OF MOISTURE DENSITY RELATIONSHIP
Tested for: Mr. Michael Smith Project: Proposed New Residence
6129 Carlton Road 6129 Carlton Road
Port St. Lucie, Florida 34987 Port St. Lucie, Florida 34987
Attn: Mr. Michael Smith Inspector: Roberto Martinez
Title: Owner
cc: TGS Project#: 21-313 -1
Date: 09/14/21
110
109
U
6
i
.@ 08
m
0
Z
O
107 oe
1
106
6 7 8 moisture Content(%)10 11 12 13
SOIL DESCRIPTION
Visual Classification: Brown slightly Silty Sand w/shells
Sample Source: Building Pad
Method of Test: T-180 i
Test Results: i
Maxium Dry Density= 109.1 pcf Optimum Moisture
IN
`',^ �ar e pecullyr�utjrnittec����^ -
r r s!? LlCl al'En jgee��
r 1
THOMAS GEOTECHNICAL SERVICEg 4'Itq i l l{t l%I%'
6594 WOODLAKE ROAD,JUPITER„FL 33458
PHONE:561-72672602
STATE OF FLORIDA PROFFESIONAL ENGINEERS LICENSE#34141
i
- I
J I
TH (D MA, S
EOTECHNICAL SERVICES
REPORT OF FIELD COMPACTION TESTS
Tested for: Mr.Michael Smith Project: Proposed New Residence
6129 Carlton Road 6129 Carlton Road
Port St. Lucie, Florida 34987 Port St. Lucie, Florida 34987
i
I
Attn: Mr.Michael Smith Inspector: Roberto Martinez
Title: Owner
cc: TGS Project#. 21-313 -2
Date: 09/14/21
Test Method ASTM D-2922(Nuclear) ASTM D-2937(Drive Sleeve)
Gauge Information ASTM D-4944(Speedy Moisture)
Gauge Make: Troxler Project Specifications
Gauge Model: 3430 95% of T-180(Modified Proctor)
Gauge S/N: 32900
Elev. Proctor Measured Calculated
or Depth Max Moisture Percent Dry Percent Spec Meets
Test Re-Test Test Density Moisture Density Compaction (From Spec?
No. No. Location (Ibs/ft^3) (Ibs/ft^3) (%) (Ibs/ft^3) (%) Above)
Building Pad-Slab-on-grade
1 SOG 12" NE Corner of Pad 109.1 6.5 110.1 100.9% 95% Yes
2 SOG 12" NW Corner of Pad 109.1 7.5 106.6 97.7% 95% Yes
3 SOG 12" Middle of Pad 109.1 6.9 108.1 99.1% 95% Yes
4 SOG 12" SE Corner of Pad 109.1 7.1 109.0 99.9% 95% Yes
5 SOG 12" SW Corner of Pad 109.1 6.4 109.8 100.6% 95% Yes
NOTES:
DEPTH OF TEST REFERENCED IN FEET
As requested,a TGS representative arrived on site as scheduled and performed Field Density Testing.
The results of our testing is presented above.
These test results apply only to the specific locations noted and may not represent any other location or
elevations.Reports may not be reproduced,except in full,without permission by.TGS rs
Ully, F1 IttEd /� f
-Y S ;rancols• omas�P E � _
�r n�lcipal;Engine�r�y g�� ,
Tr Q15
ond�}�ergtstratlonNp.f66'381
?•�' / ��^n A�1 �.ham K./�,�'.
. //rrrrr'inl1�111 �
THOMAS GEOTECHNICAL SERVICES,LLC
6594 WOODLAKE ROAD,JUPITER,FL 33458
PHONE:561-725-2602
STATE OF FLORIDA PROFFESIONAL ENGINEERS LICENSE#34141
I