HomeMy WebLinkAboutEngineering, density report "v c)gl THoM S gt,Peim�\n0 EOTECHNICAL SERVICES REPORT OF MOISTURE DENSITY RELATIONSHIP Tested for: Mr. Michael Smith Project: Proposed New Residence 6129 Carlton Road 6129 Carlton Road Port St. Lucie, Florida 34987 Port St. Lucie, Florida 34987 Attn: Mr. Michael Smith Inspector: Roberto Martinez Title: Owner cc: TGS Project#: 21-313 -1 Date: 09/14/21 110 109 U 6 i .@ 08 m 0 Z O 107 oe 1 106 6 7 8 moisture Content(%)10 11 12 13 SOIL DESCRIPTION Visual Classification: Brown slightly Silty Sand w/shells Sample Source: Building Pad Method of Test: T-180 i Test Results: i Maxium Dry Density= 109.1 pcf Optimum Moisture IN `',^ �ar e pecullyr�utjrnittec����^ - r r s!? LlCl al'En jgee�� r 1 THOMAS GEOTECHNICAL SERVICEg 4'Itq i l l{t l%I%' 6594 WOODLAKE ROAD,JUPITER„FL 33458 PHONE:561-72672602 STATE OF FLORIDA PROFFESIONAL ENGINEERS LICENSE#34141 i - I J I TH (D MA, S EOTECHNICAL SERVICES REPORT OF FIELD COMPACTION TESTS Tested for: Mr.Michael Smith Project: Proposed New Residence 6129 Carlton Road 6129 Carlton Road Port St. Lucie, Florida 34987 Port St. Lucie, Florida 34987 i I Attn: Mr.Michael Smith Inspector: Roberto Martinez Title: Owner cc: TGS Project#. 21-313 -2 Date: 09/14/21 Test Method ASTM D-2922(Nuclear) ASTM D-2937(Drive Sleeve) Gauge Information ASTM D-4944(Speedy Moisture) Gauge Make: Troxler Project Specifications Gauge Model: 3430 95% of T-180(Modified Proctor) Gauge S/N: 32900 Elev. Proctor Measured Calculated or Depth Max Moisture Percent Dry Percent Spec Meets Test Re-Test Test Density Moisture Density Compaction (From Spec? No. No. Location (Ibs/ft^3) (Ibs/ft^3) (%) (Ibs/ft^3) (%) Above) Building Pad-Slab-on-grade 1 SOG 12" NE Corner of Pad 109.1 6.5 110.1 100.9% 95% Yes 2 SOG 12" NW Corner of Pad 109.1 7.5 106.6 97.7% 95% Yes 3 SOG 12" Middle of Pad 109.1 6.9 108.1 99.1% 95% Yes 4 SOG 12" SE Corner of Pad 109.1 7.1 109.0 99.9% 95% Yes 5 SOG 12" SW Corner of Pad 109.1 6.4 109.8 100.6% 95% Yes NOTES: DEPTH OF TEST REFERENCED IN FEET As requested,a TGS representative arrived on site as scheduled and performed Field Density Testing. The results of our testing is presented above. These test results apply only to the specific locations noted and may not represent any other location or elevations.Reports may not be reproduced,except in full,without permission by.TGS rs Ully, F1 IttEd /� f -Y S ;rancols• omas�P E � _ �r n�lcipal;Engine�r�y g�� , Tr Q15 ond�}�ergtstratlonNp.f66'381 ?•�' / ��^n A�1 �.ham K./�,�'. . //rrrrr'inl1�111 � THOMAS GEOTECHNICAL SERVICES,LLC 6594 WOODLAKE ROAD,JUPITER,FL 33458 PHONE:561-725-2602 STATE OF FLORIDA PROFFESIONAL ENGINEERS LICENSE#34141 I