FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DIAMOND SANDS - CM-DS-31
Builder Name: PHOENIX HOMES
Street: LOT-31, 8208 S OCEAN DR
Permit Office: CITY OF PT ST LUCIE
City, State, Zip: PT ST LUCIE , FL,
Permit Number:
Owner: VENATION HOLDING LLC
Jurisdiction: 661200
Design Location: FL, VERO 8F-ACH_MUNICIPAL_ARPT
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeO935.8 sgft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.1 6174.60 ft'
2. Single family or multiple family Detached
b. Frame - Wood, Adjacent
R=11,0 694.76 ft'
3. Number of unite, if multiple family 1
c. Concrete Block - Int Insul, Adjacent
R=4.1 66.50 ft'
4. Numbar of Bedrooms 4
d. NIA
11. Ceiling Types (3228.7 5gft.)
R= ft'
Insulation Area
S. Is this a worst case? No
a. Cathedfal/Singla Assembly (Unvented)R=20.0 3228.70 ft°
6. Conditioned floor area above grade (ft') 5554
b. N/A
R= ft'
Conditioned floor area below grade (" 0
c. N/A
R= ft'
7. Windows(1650,3 sgft.) Description Area
12. Ducts
a. Sup: Mein, Rat: Main, AH: Main
R fF
6 1130
a. U-Factor: Sgl, U=1.03 812.92 ft'
SHGC: SHGC=0.34
b. U-Factor. 591, U=1.11 860.00 ft'
13. Cooling systems
kBtu/hr Efficiency
SHGC; SHGC=0.22
a. Central Unit
167,2 SEER:16.00
c. U-Factor. Sgl, U=1.11 100.00 fF
SHGC; SHGC=0.22
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average overhang Depth: 2.799 ft.
a. Electric Heat Pump
164.1 HSPF:8.73
Area Weighted Average SHGC: 0.278
8. Skylights Area
o. U-Factor.(AVG) N/A ft'
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (2730.3 sqft.) Insulation Area
EF: 0.900
a, Floor over Garage R=11.0 2106,60 ft'
b, Conservation features
b. Slab -On -Grade Edge Insulation R-0.0 447.00 ft'
None
a other (see details) R= 175.70 R2
18, Credits
Pstat
Total Proposed Modified Loads: 186.40
PASS q�
Glass/Floor Area: 0.292 Total Baseline
Loads: 194.38
I hereby certify that the plans and specifications covered by
Review of the.plans and
D,K S>%fi gTA�
this calculation are in compliance with the Florida Energy
specifications covered by this
(7p
Code
calculation indicates compliance
n
with the Florida Energy Code,
PREPARED BY: \ >an4 i ��� S C��
Before construction is completed
w
this building will be inspected for
DATE: -.
compliance with Section 553.908
r a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,
vrC�we
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barter and insulation inspection Checklist, in accordance with R402A.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5,00 ACH50 (R402A.1.2).
5110/2021 11:20 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
rnRne P1dnF.')nWI INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
DIAMOND SANDS - CM•DS• Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 5654
Lot#
Owner Name:
VENATION HOLDING
LLC Total Stories; 2
Block/80division:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
PHOENIX HOMES
Rotate Angle: 0
Street: LOT41, 8208 S OCEA
Permit Office;
CITY OF PT ST LUCIE
Cross Ventilation:
County: St. Lucie
Jurisdiction:
061200
Whole House Fan:
City, State, Zip: PT ST LUCIE ,
Family Type:
Detached
FL,
New/Exis6ng:
New (From Plans)
Comment
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
Design Location
TMY Slte 97.5 % 2.5 %
FL, VERO_BEACH_MUN FL VERO_BEACH_MUNI 45 90
70
75 299 64 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
5654 67848
SPACES
Number
Nome
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
5654 67848 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor iype
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
_ 1 Slab -On -Grade Edge Insulatio Main 98,17 ft 0
447 ftz
.__. 1 0 0
2 Floor over Garage
Main _-- _.,..
2106.8 W
11 0.75 0 0.25
3 Raised Floor
Main ___ ---
176.7 ft'
11 0 0 1
ROOF
Roof Gable Roof
Red
Solar SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Barr
Absor, Tested Tested Insul. (deg)
1
Hip
Metal 3403 It' Oft' Medium
N
0.75 No 0.9 No 0 18.43
ATTIC
J #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 3228.7 ft2
N N
5110/2021 11:20 AM EnergyGaugeO USA 7.0.00 - FlaRee2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R406-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Cathadral/Single Assembly (Unvented Main
20
Blown
3095.4 f'
0.11
Wood
_
2
Cathedral/Single Assembly (Ur)Vented Main
20
Blown
133.3 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar
Below
Space
0
1
W
Exterior
Concrete Block -Int Insul
Main
4,0999
19
4 10
6
203.0W
0
0.5
0
_
_ 2
S
Exterior
Concrete Block - Int Insul
Main
4.0999
6
4 10
5
$6.5 ft'
0
0.5
0
W
Exterior
Concrete Block - Int Insul
Main
4.0999
17
2 11
6
197.4 ft2
0
0.5
0
-3
4
W
Exterior
Concrete Block - Int Insul
Main
4.0999
40
10 12
490.0 ft'
0
0.5
0
5
S
Exterior
Concrete Block - IM Insul
Main
4,0999
17
10
170.0 ft'
0
0.5
0
6
S
Exterior
Concrete Block - Int Insul
Main
4.0999
17
11
6
195.5 ft2
0
0.6
0
7
S
Exterior
Concrete Block - Int Insul
Main
4,0999
35
4 12
424.0 f12
0
0.5
0
8
E
Exterior
Concrete Block - Int Insul
Main
4.0999
6
4 10
63.3 ft'
0
0.5
0
_
9
E
Exterior
Concrete Block - Int Insul
Main
4.0999
51
8 12
620.0 f12
0
0.5
0
._--, 10
N
Exterior
Concrete Block - Int Insul
Main
4,0999
6
10
$0.0 42
0
0.01
0
N
Exterior
Concrete Block - Int Insul
Main
4.0999
3
4 11
6
38.3 W
0
0.01
0
-it
N
Exterior
Concrete Block - Int Insul
Main
4.0999
60
12
720.0 ft2
0
0,01
0
-12
13
W
Exterior
Concrete Block - Int Insul
Main
4,0999
16
6 10
165.0 ft2
0
0.5
0
14
W
Exterior
Concrete Block, Int Insul
Main
4.0999
35
6 11
390.5 ft'
0
0.5
0
15
S
Exterior
Concrete Block - Int Insul
Main
4.0999
12
10
120.0 ft2
0
0.5
0
16
S
Exterior
Concrete Block -Int Insul
Main
4.0999
64
4 11
707.7 ft2
0
015
0
17
E
Exterior
Concrete Block - Int Insul
Main
4.0999
2
10
6
21.0 W
0
0.5
0
18
E
Exterior
Concrete Block - Int Insul
Main
4.0999
54
11
594.0 ft'
0
015
0
_
19
N
Exterior
Concrete Block - Int Insul
Main
4.0999
24
6 10
245.0 ft'
0
0.01
0
_
20
N
Exterior
Concrete Block - Irit Insul
Main
4,0999
15
8 10
8
164.5 ft2
0
0101
0
21
N
Exterior
Conorete Block - Int Insul
Main
4.0999
47
2 11
518.8 ft2
0
0101
0
22
N
Garage
Frame - Wood
Main
11
66
2 10
6
694.8 ft'
0.23
0.01
0
�23
N
Garage
Concrete Block- Int Insul
Main
4,0999
6
4 10
6
6615 ft2
0
0.01
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
In
Height
Ft In
Area
Ft
1
W
Wood
Main
None
.46 3
10
30 ft
2
N
Wood
Mein
None
.46 2
8
B
21.3 ft,
3
N
Wood
Main
None
.46 2
8
B
21.3 ft,
_
4
N
Wood
Main
None
.46 2
6
a
20ft
5
N
Wood
Main
None
.46 , 2
6
8
20 ft2
5/10/2021 1120 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered Proposed
orientation.
Overhang
#
omt
Wall
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth Separation
Int Shade
1
W
14
Metal
Single (Tinted)
Yes
1.04
0.2
Y
42.0 ft'
2 ft 8 in
0 It 4 In
None
_
2
W
14
Metal
Single (Tinted)
Yes
1.03
0.34
Y
21.0 ft"
2 It 6 in
0 It 4 in
None
3
W
14
Metal
Single (Tinted)
Yes
1.03
0.34
Y
27.0 ft2
2 ft 6 In
7 ft 4 in
None
^- 4
W
4
Metal
Single (Tinted)
Yes
1.03
0.34
Y
90,0 ft2
2 ft 6 in
14 It 4 in
None
5
W
14
Metal
Single (Tinted)
Yes
1.11
0.22
Y
100.0 ft'
2 ft 6 in
0 it 4 in
None
_
6
W
4
Metal
Single (Tinted)
Yes
1,03
0.34
Y
96.7 ft2
6 ft 8 in
2 ft 0 In
None
7
W
1
Metal
Single (Tinted)
Yes
1.03
0.34
Y
40.0 ft2
5 If 4 in
0 ft 8 in
None
J 8
W
3
Metal
Single (Tinted)
Yes
1.11
0.22
Y
100.0 ft2
3 ft 4 in
2 ft 0 in
None
- 9
S
16
Metal
Single (Tinted)
Yes
1,03
0.34
Y
54.0 ft2
2 ft 6 in
oft 4 in
None
10
S
6
Metal
Single (Tinted)
Yes
1.03
0.34
Y
42,0 ft2
2 it 6 in
3 ft 4 in
None
11
S
5
Metal
Single (Tinted)
Yes
1,03
0.34
Y
25.0 ft2
2 ft 6 in
3 It 4 in
None
_
12
S
15
Metal
Single (Tinted)
Yes
1.03
0.34
Y
8,8 ft2
2 It 5 In
0 ft4 in
None
13
S
16
Metal
Single (Tinted)
Yes
1.03
0.34
Y
27.5 ft2
2 it 6 in
0 If 4 in
None
�- 14
S
7
Metal
Single (Tinted)
Yes
i.w
0.34
Y
96.0 ft2
2 ft 6 in
3 it 4 in
None
15
S
5
Metal
Single (Tinted)
Yes
1.03
0.34
Y
12.5 1`2
2 ft 6 in
3 ft 4 in
None
16
E
18
Metal
Single (Tinted)
Yes
1,03
0.34
Y
120.0 W
2 ft 6 in
0 it 4 in
None
_
E
18
Metal
Single (Tinted)
Yes
1.11
0.23
Y
100.0 ft'
. 2 ft6 in
0 ft 4 in
None
_ 17
98
E
9
Metal
Single (Tinted)
Yes
1.11
0.22
Y
100.0 ft2
2 It 6 in
1 ft 8 in
None
19
E
9
Metal
Single (Tinted)
Yes
1.11
0.22
Y
200.0 ft9
2 ft 6 in
1 ft 8 in
None
E
18
Metal
Single (Tinted)
Yes
1,11
0.22
Y
150.0 ft2
2 It 6 in
0 ft 4 In
None
20
- 21
N
21
Metal
Single (Tinted)
Yes
1.03
0.34
Y
6.7 11:2
2 ft 6In
1 ft 8 ir1
Nona
22
N
21
Metal
Single (Tinted)
Yes
1.03
0.2
Y
24.0 fl
2 ft 5 In
3 it 8 in
None
J 23
N
10
Metal
Single (Tinted)
Yes
1.03
0.2
Y
21.3 ft2
2 it 6 in
3 ft 4 in
None
N
20
Metal
Single (Tinted)
Yes
1.03
0.34
Y
18,0 ft2
2 ft 6In
1 ft 8 in
None
24
- 25
N
20
Metal
Single (Tinted)
Yes
1.03
0.34
Y
36.0 ft2
2 It 6 in
0 ft 4 in
None
J
N
12
Metal
Single (Tinted)
Yes
1.03
0.34
Y
42.0 ft2
2 It 6In
14 It 6 in
None
26
�- 27
N
12
Metal
Single (Tinted)
Yes
1,03
0.34
Y
19.0 ft2
2 ft 0 in
2 ft 6 in
None
19
Metal
Single (Tinted)
Yes
1,03
0.34
Y
15,0 ft2
2 ft 6 in
0 ft 4 in
None
28
N
N
12
Metal
Single (Tinted)
Yes
1.03
0.34
Y
15.8 fie
2 ft 8 in
14 It 5 In
None
29
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Ins
1
3971.095975
ft2 3971.095975 ft2
242,25 it
10.5 ft
1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehousa Proposed ACH(50) .000381 5654 310.2 582.36 .152
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
5110/2021 11:20 AM EnergyGauge® USA 7,0.00 - FlaRe52020 FBC 7th edition (2020) Compliant Software
Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
_
1 A
18
1 C
1 D
Electric Heat Pump/
Electric Heat Pump/
Electric Heat Pump/
Electric Heat Pump/
None
None
None
None
HSPF:8.5
HSPF:8.5
HSPF;9
HSPF:9
54 kStu/hr
35 kWu/hr
46.5 kBtu/hr
28.6 kBtu/hr
1
1
1
1
sys#1
sys#1
sys#1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow
SHR
Block
Ducts
_
1 A
1 B
1 C
1 D
Central Unit/
Central Unit/
Central Until
Central Unit/
None
None
None
None
Singi SEER: 16 55 kBtu/hr 1650 arm
Singl SEER: 16 35 k8tu/hr 1050 arm
Singi SEER: 16 46 kBiu/hr 1440 cfm
singl SEER: 15 29.2 kBtu/hr a75 ofm
0.75
0.75
0.75
0,75
1
1
1
1
sys#1
sys#1
sys#1
sys#1
HOT WATER SYSTEM
#
System Typo SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric None
Garage
0,9 50 gal 70 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cen # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
PEP
None None
ft2
DUCTS
#
�• Supply --
Location R•Value Area
-- Return --
Location Area Leakage Type
Air CFM 25 CFM25
Handler TOT OUT
QN
RLF
HVAC #
Heat Cool
1
Main 6 1130 ft'
Main
282 fN Defauk Leakage
Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling [r Jan [[ ]] Feb [ j Mar
Heating [X� Jan [X] Feb [X_ ] Mar
Venting 17 Jan [[ 11 Feb [XJ Mar
Coiling Fans:
[ ] A r (] Ma [Xj Jun Jul
L J AApr t 1 May f 1 Jun Jul
tXl l 1 I ] Jun
Au rrX Se (((
Aug [ Sep
Od
Oct
�[[X7] Nov
[X] Nov Nov
Dec
Dec
5/10/2021 11:20 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
u.mt rT ¢i Huiii ri4r-rKl ICY' REPORT
FORM K4u5-20Zu
uvrvr
vvu.....-..w. --
Thermostat Schedule;
HERS 2006 Reference
Hours
8
9
10
11
12
Schedule Type
1
2
3
4
5
6
7
Cooling (WP)
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
PM
80
80
80
78
78
78
7788
78
78
78
80
78
Heating (WD)
68
68
68
68
68
66
68
68
68
68
68
PM
68
Heating (WEH)
66
68
68
68
6
8
68
'Ole
68
68
68
68
68
PM
8
6
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(6lbs s
.ft,
0 111
0 it
0.3
Main
rgY
6/1012021 11:20 AM
Ene Gauge® USA 7.0.00 - FleRes2020 FeC 7th Edition (2020) Compliant Software Page 6 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
LOT-31, $208 S OCEAN DR, PT ST LUCIE, FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
a. concrete Block - Int Insul, Exterior
R=4.1
6174.60 ft
2. Single family or multiple family
Detached
b. Frame - Wood, Adjacent
R=11.0
04.76 ft
3. Number of units, if multiple family
1
c. Concrete Block - tnt Insul, Adjacent
R=4.1
66.50 ft-
4
d. N/A
R=
ft'
4. Number of Bedrooms
11. Ceiling Type and insulation level
Insulation
Area
S. Is this a worst case?
No
a. CalhedrallSingle Assembly (Unvented)R=20.0
3228.70 ft'
6, Conditioned floor area (W)
5654
b. NIA
R=
R=
ff=
ft'
7, 1Niodows"" Description
Area
c. N/A
12. Ducts, location & insulation level
R fta
a. U-Factor: sgl, U=1.03
812.92 ftA
a. Sup: Main, Rot: Main, AH: Main
6 1130
SHGC; SHGC=0.34
b. U-Factor: Sgl, U=1.11
650.00 ft'
SHGC; SHGC=022
13. Cooling systems
kBtuthr
Efficiency
0. U-Factor: $91, U=1.11
100,00 ft,
a. Central Unit
167.2
SEER:16.00
SHGC: SHGC=0.22
d. U-Factor: other (see details)
87.33 ft?
14. Heating systems
k6iv/hr
Efficiency
SHGC: other (see details)
a. Electric Heat Pump
164A
HSPF:8.73
Area Weighted Average Overhang Depth:
2,709 ft.
Area Weighted Average SHGC:
0.278
8, Skylights Description
Area
18. Hot water systems
Cap: 60 gallons
a. U-Factor(AVG): N/A
ft'
a. Electric
EF: 0.9
sHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Floor over Garage
R-11.0 2106.60 ft'
Credits (Performance method)
Pstat
b. Slab -On -Grade Edge Insulation
R=0.0 447,00 ft"
c. other (sea details)
R= 176,70 fN
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
"*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/10/2021 11:20 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2070) Compliant Software Page t of 1
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Altemative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation inspection Component Criteria checklist (Table R402.4.1.1- one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page), exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ ff Form P405 duct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
5/10/2021 11:14:24 AM EnergyCiaugea USA 7.0.00 - FlaRes202o FBC 7th Edition (2020) Compliant Software Page 1 of 1
Florida Building Code. Enemy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: LOT-31, 8208 S OCEAN DR Permit Number:
PT ST LUCIE , FL,
MANDATORY REQUIREMENTS -see inaivtaual coae secuons Tur fun oGrsrua.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building Official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9086, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presokl and
nonpresold residential buildings. The EPL display card contains Information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the pans
and specifications submitted to demonstrate code Compliance for the building. A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402A Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section G402.5,
R402.4.1 Building thermal anvelope.Ths building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1,2, The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the bullding thermal envelope as listed in Table R402A,1.1 shall be installed in accordance
with the manufacturers instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verity compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verifled as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour In Climate Zones 3 through a. Testing shall be Conducted in
accordance with ANSI/RESNET/ICC aso and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing Shall be conducted by either
Individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings In which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Ex(erior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures. But not sealed beyond intended
2. Dampers Including exhaust, intake, makeup air, bockdraft and flue dampers shall be closed,
infiltration control measures.
3, interior doors, It Installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return n:giaters, if installed at the time of the test, shell be fully open.
R402.4.2 Fireplacas. New wood -burning fireplaces shall have tight -fining flue dampers or doors, and outdoor combustion air, Where
fusing tight -fitting ireplace. Where usl g tight Fitoors on ting dolft fireplaces listed and labeled om on masonry fireplaces, theldoo accordance
be with
and labeled doors
accordanacetested
with UL 907 listed for the
R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 um
per square foot (1.5 Lia/m2), and swinging doors no more than 0.5 dm per square foot (2.6 Us/1112), when tasted according to NFRC 400 or
AAMA/ WDMAICSA 101/1.5.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer,
Exception: Sae -built windows, skylights and doors
51101Z021 11:17 AM EnergyGaugs® USA 7.0.00 - FlaRes2020 FBC 711, Edition (2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel•buming appliances, In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from Inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement The door into the room shall be
fully gaskated and any water lines and ducts in the room Insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8,
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes Installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.s Recessed lighting. Recessed luminaires installed In the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 efm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403,1 Controls,
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
Q R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary alectric-resistance heat shall have controls
that, except dvdng defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 sealing (Mandatory) All ducts, air handlers, filter boxes and building
shall cube ies that
form the primary and sealed in aircontainment
ante withaSection
eays
for air distribution systems shall be considered ducts or plenum chambers,
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below -
Duct tightness shall be verified by testing in accordance with ANSURESNE( 11CC 380 by either individuals as defined in Seddon 553,993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105 3 , (9) or (I), Florida Statutes, to be "substantially leak free' In
accordance with Section R403.3.3.
Q R403.3,2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance wfth ASHRAE 193,
❑ R403,3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -In test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system,
including the manufacturer's air handier enclosure if installed at the time of the test. All registers shall be taped or otherwise
sealed during the test.
2. Poetconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w,g. (25 Pa) across the entire
system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code, Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage, and a duct airleakage, Qn to the outside of less than 0. 080 (where Qn =
duct leakage to the outside in cfm per 100 square feet of Conditioned floor area tested at 25 Pascals) is indicated in the
compliance report for the proposed design.
A Written report of the results of the test shall be signed by the party conducting the test and provided to the code officlal.
11403.3.5 Building cavities (Mandatory). Building framing cavlties shall not be used as ducts or plenums.
R403A Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 5VF (13°C) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, Including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted,
R403,5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are
installed, they shall be in aocoroance with section R403.5.1.1. Heat tract temperature maintenance systems shall be in accordance with
Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems, Heated water circulation systems shall be provided with a circulation pump. The system realm pipe shall
Q be a dedicated return pipe or a cold water supply pipe. Grevhy and thermoslphon circulation systems shall be prohibited. Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The
controls shall automatically turn off the pump when the water in the circulation loop Is at the desired temperature and when there is no
demand for hot water.
R403.6.1.2 Most trace systems, Elactrlc heat trace systems shall comply with IEEE 515.1 or UL 515, Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used In the occupancy.
5/10/2021 11:17 AM EnargyGaugeo USA 7.0.00 - FlaRes2020 FBC Ah Edition (2020) Compliant 5oftware Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.6.6 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 31& inches (69 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5,6 Water heater o icfencles (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100'F to 140OF (36°C to 6010).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked cin tilt breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of
combustion types of service water -heating systems to be turned off.
❑ R403.5.6.2 Water -heating equipment. Water -healing equipment installed in residential units shall most the minimum efficiencies of
Table 0404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide hosting functions as pan of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.6.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system aball be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be Installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be Installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
in
R403.6.1 Whole -house mechanical ventilation system fan efficacy, When Installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6,1.
Exception: Where an air handler that is Integral to tested and listed HVAC equipment is used to provide whole -house mechanical
ventilation, the air handler shall be powered by an electronically commutated motor.
❑ R403.8.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics.
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or $pas.
3. if ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-1 t and the ceiling shall be Insulated to a minimum of R-19. space permitting, or R•10
otherwise.
R403,7 Heating and cooling equipment.
R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized In accordance with ACCA Manual S based
13 on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies, based on bullding loads for the directional orientation of the building. The manufacturer and model 00mber of the
outdoor and indoor units (if split system) shall be submitted along wlth the sensible and total cooling capacities at the design
conditions described in Section R302,1, This Code does not allow designer safety factors. provisions for future expansion or other
factors that affect equipment sizing. System sizing Calculations shall not include loads created by local Intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
Installed. TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOWATE MINIMUM
MINIMUUMt EFFIICACY a
AIRFLO) RATE MAXIMU IV
HRV or ERV
Any
1.2 orm/watt
Any
Range hoods
Any
2.8 cfmAvatt
Any
In -line fen
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cf ntWW
a90
Bathroom, utility room
90
2.6 dim/watt
Any
For $I: 1 cfrn = 28.3 L/min. a. When tested in accordance with HVI Standard 916
5/10/2021 11:17 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FSC 7th Edition (2020) Compliant Software Page 3 of 6
MANDATORY REQUIREMENTS - (Continued)
❑R403.7.1,1 Cooling equipment capacity. Cooling only equipment shall be selected se that Its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total bad calculated according to the procedure selected in
Section R403.7, or the closest available site provided by the manufacturer's product lines, The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance dais shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the bad calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature,
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the toad
calculation and shall be adjusted for return side gains •rf the return duct(s) is installed In an unconditioned space.
Exceptions:
1. Attached Single- end multiple-famiy residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 30 percent of that toad.
2.
When signed and sealed by aFlorida-registered engineer, in attached single -and multiple -family units, the capacity o
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Haat pump sizing shall be based on the cooling requirements as calculated according to Section
❑ R403,7,1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even lt
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403,7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1, A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403A Systems serving multiple dwelling units
Energy (Mandatory),
Systems
serving Prmultiple
isions ndlieulling units of Section all comply with Sections
❑ 0403 and 0404 of the Florida Building Code, gY
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
❑ shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10'C), and no
precipitation Is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.9°C).
❑ R403.10 pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403,10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
❑ Integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 ram) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater, Gas-ilred heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
n
LI shall be installed for heaters and pump motors. Heaters and pump motors that have buih4n time switches shall be In compliance with this
section,
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3, Where pumps are powered exclusively from on -site renewable generation.
5/10/2021 11,17 AM EnergyGauge® uSA 7.0.00 - F1aRes2020 FBC 7th Edition (2020) Compliant Software page 4 of 5
R403.10.3 Covers Outdoor heated Swimming pools and outdoor permanent spas shall be equipped With a vapor -retardant cover on or at
El the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or Soler energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas• and oll-fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ effcency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21,66. fool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
❑R403.10.5 Heat pump pool heaters. Heat pump pool heaters Shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature, A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
❑R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
R403.13 Dehurildifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 litersl kWh the total dehumidifier capeohy for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pinWday.
2. The dehumidifier shall be controlled by a sensor that is Installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned apace shall be insulated to a minimum of R-2.
4, Condensate disposal shall be in accordance with Section M14113,1 of the Florida Bulkling Code, Residential.
❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, In addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft
damper shall be instelled in the supply air duct between the dehumidifier inlet and outlet duct.
2, If a ducted dehumidifier Is configured with only its supply duct connected into the Supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
❑R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 451umens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights.
5/113/2021 11:17 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.41.1 a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: DIAMOND SANDS - CM-DS-31 ES
Delimit Office;' CITE F PTOM LUCIE
EA
Street: LOT-31, $208 S OCEAN DR
Permit Number:
X
O
City, State, Zlp: PT 57 LUCIE FL ,
Owner VENATION HOLDING lLC Jurisdiction: 801200
W
U
Design Location: FL, VERO_BFACH_MUNICIPAL_ARP7
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
General
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks Or Joints in the air barrier shall be seated.
The air befrier in any dropped callingisoffit shall be aligned with
The insulation In any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air border shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall 6e
wittall be insulated by completely filling the cavity
h a material having a thermalresistance of R-3
sealed.
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
Continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
skylights and framing shall be seated.
and doors
Rim joists
RIM joists shall include the air border.
Rim joists shall be insulated,
Floors
The air barrier shall be installed at any exposed edge Of
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
(including
insulation.
suhfloor decking, or floor framing cavity insulation
above -garage
shall be Permitted to be in contact with the top side
and cantilevered
of sheathing, or continuous insulation installed an
floors)
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth In unvenled crawls aces shall be covered with
p
Where provided instead of floor insulation, Insulation
shall be permanently attached to the crawlspece wall
.
a Class I vapor retarder with overlapping joints taped.
Duet shafts, utility penetrations, and flue shafts opening to
Shafts, penetrations
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installaflon readily conforms to the available cavity
spaces.
Garage separation
Air sealing shell be provided between the garage and conditioned Spa
s.
Recessed lighting
Recessed light fixtures installed In the building thermal envelope
thermal envelop shall be air tight and ICed ligt fixtures Installed in the acted.
shall be sealed to the finished surface.
Batt insulation shall be out neatly to fit around wiring
Plumbing and wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
nhiDd nining and wiring
Shower/tub
The air barter installed at exterior walls adjacent to showers and
Exteriorwalls adjacent to showers and tubs Shall
on exterior wall
tubs shell separate them from Ills showers and tubs.
b
Electricauphone box or
The air barrier shall be installed behind electrical or communication
exte iorwalls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be seated to the sub -Poor, wall covering or
When required to be sealed, concealed fire sprinklers shall only be
Concealed
sealed in a manner that Is recommended by the manufacturer.
sprinklers
Caulking or other adhesive sealants shall not be used to fill voids
_ _ ._: u.
a. In addition, Inspection of log walla snsn oe o, uuw,va„w �• • - � r am- ---- - - - — 5/10/2021 11:17 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661200 Permit #:
Builder: PHOENIX HOMES Community: Lot: NA
Address: LOT-31, 8208 S OCEAN DR
City: PT ST LUCIE State: FL Zip:
6.000
_
x 60 _ 67848 — Method for calculatinq buildln volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
PASS 0 Code software calculated
when AGH(50) )s less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSURESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either Individuals as defined In Section 553.993(5) or (7), Florida Sfatuea.or Individuals licensed as set forth in section
489,105(3)(1), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to theoode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers Including exhaust, Intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond Intended infiltration control
measures.
$. Interior doors, if installed at the time of the test, shall be open,
a. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be Closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off,
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
5/10/2021 11:21 !00 AM EnergyGaugee USA 7.0.00 • FlaRes202o FBC 7th Edition (2020) Compliant Software Page 1 of 1
_ Job; CM-DIAMND-SNDS-31-...
wh9htN project Summary PByte: 5-e-21
ZONE #1
CONNIE'S E-CALCS
Phone: 501,748-7745
Project Information
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT-31, 8208 8 OCEAN DR, CITY OF PT ST LUCIE
Notes: PHOENIX HOMES
Weather:
Winter Design Conditions
Outside db 43 of
Inside db 70 F
Design TO 27
Vero Beach Municipal AP, FL, US
Heating Summary
Structure 29489 Btuh
Ducts 1474 Btuh
Central vent (0 cfm)
(none)0 Btuh
Humidification 0
Piping Btuh
Equipment load 30963 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces
Ile
ti? Co 21
21
?ft°) 31
Area (ft25572 25572
Volume
Air changes/hour 0.99 0'12
53
Equiv. AVF (cfm)
Heating Equipment Summary
Make CARRIER
Trade CARRIER
AHR I ref 202362410 0
8.5 HSPF
54000
Btuh aQ 47°F
1833
fm
0,059
cfm/Btuh
0
in H2O
point = 15 OF
Backup:
Input = 5 kW, Output = 17061 Btuh, 100 AFUE
Summer Design Conditions
Outside db
9966
F
Inside db
Design TD
21
°F
Daily ranqe
L
50
Moisture differrence
74
gr/ib
Sensible Cooling Equipment Load Sizing
Structure
42808
4281
Btuh
Stuh
Ducts
Central vent (0 cfm)
0
Btuh
(none)
Blower
78
Btuh
Use manufacturer's data
n
Ratelswing multiplier
Equipment sensible load
1.01
47591
Btuh
Latent Cooling Equipment Load Sizing
Structure
3459
Btuh
Ducts
2907
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
63W
Btuh
Req. total caTpoac'llty at 0.1 SHR t)
53 5 7
Btuh
ton
Cooling Equipment Summary
Make CARRIER
Trade CARRIER
Cond CH16NA060
Coil FB4CNP061
AHRI ref 202362410
Efficiency 13.0 EER, 16 SEER
Sensible cooling
Latent cooling
38500
16500
Btuh
Stuh
Total cooling
55000
1833
Btuh
cfm
Actual air ow
Air flow factor
0.039
cfm/Btuh
Static pressure
0
0.86
in H2O
Load sensible heat ratio
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-May-10 11:11:54
�a--Right-Suite® U�wwssl 201919.0.20 RSUW049 Page 1
/ 7� ci1.,CM-DIAMNDSND841-H0-12.mp Calc=MJ8 Front Door races: W
Load Short Form JW CM-DIAMND-8ND8-31•...
It 1Nrf 1t5E1 ZONE #1 Date: 6.9-21
8y,
CONNIE'S E-CALCS
Phone: 561-748-7745
• eject intori-nation
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT-31, 8205 S OCEAN DR, CITY OF PT ST LUCIE
Htg Clg Infiltration
Outside db (OF) 43 96 Method Simplified
Inside db (`F) 70 75 Construction quality Average
Design TD (OF) 27 21 Fireplaces 0
Daily range L
Inside humidity (%) 50 50
Moisture difference (grllb) 22 74
HEATING EQUIPMENT
Make
CARRIER
Trade
CARRIER
Model
CH16NAD60
AHRI ref
202362410
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 15 OF
Backup:
8.5 HSPF
54000
Btuh @ 47'F
27
OF
1833
cfm
0,059
cfm/Btlih
0
in H2O
F E
COOLING EQUIPMENT
Make CARRIER
Trade CARRIER
Cond CH16NA060
Coil FB4CNP061
AHRI ref 202362410
Efficiency 13.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
38500
Btuh
16500
Btuh
55000
Btuh
1833
cfm
0.039
cfm/Btuh
0
in H2O
0.88
I = _
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
HtgAVF
(cfm)
C19AVF
(Cfm)
LBY,OF,KTC,DN,UT
2181
30963
47088
1833
1833
ZONE #1 d
Other equip loads
Equip. aQ 1,o1 RSM
Latent cooling
2131
30963
0
47088
78
47591
6366
1833
1833
-.-e�
anm�
caQFR
1R:iR
1833
TO PALS
c ro.r
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
_ wrl tsoft• 2021-May-1011:11:64
�C� ,,,,, r ght5K .V Right-3uge® unlverael 2019 19.0.20 RSUD3049 Pegs 1
A!& C:1ec\CM-DIAMND-9NDSJl-HL-12. Np Calc-MJ0 Franl D 00f faces: W
wxsoft° ZONE #2 Summary
CONNIE'S E-CALCS
piiom: 561-7467745
Project• •
Job: CM-DIAMND-SNDS-31....
Date: 5-9-21
By-.
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT 31, 8208 S OCEAN DR, CITY OF PT ST LUCIE
Notes: PHOENIX HOMES
Weather: Vero Beach Municipal AD, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43 of
70 F
Outside db
Inside db
75 96
F
Inside db
Design TD 27 OF
Design TD
21
°F
Daily range
0osleifn5Mitur
difference
74
grub
Heating Summary
Structure 23486 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Pip99 23406 Btuh
Equipment load
Infiltration
Method Simplified
Construction quality Averago
Fireplaces
He 18
�6
1 6
Area (ft
Volume 1
16
14016
14016
Air cha /hour
A F
0.37
0,20
Equiv. (cfm)
Heating Equipment Summary
Make CARRIER
Trade CARRIER
Model CH16NA036
AHRI ref 202362189
8.5 HSPF
35000
Btuh @ 47°F
1167
cfm
0.050
cfm/Btuh
0
in H2O
point = 22 OF
Backup:
Input = 5 kW, Output = 17061 Btuh, 100 AFUE
Sensible Cooling Equipment Load Sizing
Structure
31142
Btuh
Ducts
Central vent (0 cfm)
0
0
Btuh
Stuh
(none)
Blower
78
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment sensible load
1.01
31502
Btuh
Latent Cooling Equipment Load
Sizing
Structure
2722
0
Btuh
Ducts
Central vent (0 cfm)
Btuh
Equipment latent load
2722
Btuh
EauipmentTotat Load�,aan+Lat)
34223
Btuh
Req. total Capacity at 0
Cooling Equipment Summary
Maka CARRIER
Trade CARRIER
Cond CH16NA036
Coil FX4DNB049
AHRI ref 202362189
Efficiency 13.0 EER, 16 SEER
Sensible cooling
24500
10500
Btuh
Stuh
Latent cooling
Total cooling
35000
Btuh
Actual air flow
1167
cfm
Air flow factor
0.037
0
cfm/Btuh
in H2O
Static pressure
Load sensible heat ratio
0.92
Calculations approved byACCA to meet all requirements of Manual J 8th Ed,
2021-May-10 11; 11:64
Rlgnt-Sw1em Universal 201919.0.20 RSU03049 pap 2
AK C:tao1CM-DIAMND-ENDS-3I-ML-12,mp Cato-MJ8 Front Door faces: W
Load Short Form Job: CM-DL4MND-SNDs 31•...
.y Date: 6.9.21
ZONE #,2 By;
CONNIE1 E-CALCS
Pnone: 60-749-770
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT 31, 8208 S OCEAN DR, CITY OF PT ST LUCIE
Htg
Clg Infiltration
Simplified
Outside db (°F)
Inside db (°F)
43
70
96 Method
75 Construction quality Average
Design TD (°F)
27
21 Fireplaces
Daily range
Inside humidity (%)
50
L
50
Moisture difference (grAb)
22
74
HEATING EQUIPMENT
Make
CARRIER
Trade
CARRIER
Model
CH16NA036
AHRI ref
202362189
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 22 OF
Backup:
8.5 HSPF
35000
Btuh @ 47°F
27
OF
1167
cfm
0.050
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make CARRIER
Trade CARRIER
Cond CHJBNA036
Coil FX4DNB049
AHRI ref 202362189
Efficiency 13.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
245a0
Stuh
10500
Btuh
35000
Stuh
1167
cfm
0.037
cfm/Stuh
0
in H2O
0.92
= 17
1
AME
Area
Htg load
CBIg load
Ht 'VF
C119nAVF
(ft)
(Stuh)EST
7CW
1168
23486
31142
1167
1167
d
1168
2348631142
1167
1167
ereqpads
0
78
3 22
Equip. @ 1.01 RSM
72
272
Latent cooling
.Al.
oaeRR
34223
1167
1 1167
TOTALS .1" ----
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
•. 2021-May-10 11:11:m
A `T Wr�ffiott- Right-WM universal 201919.0.20 RSU03049 P�9` 2
D:Nac1CM-DIAMND-ENDS-31-HL-12.,p calc=MJa Front Door facesW
vi it c E` ZONE #3ummary
CONNIE'$ E-CALCS
Pro-ect Information
Job,. CM-DIAMND•8NDS-31•...
Data: 5.9.21
By:
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT-31, 8208 S OCEAN OR, CITY OF PT ST LUCIE
Notes: PHOENIX AOIIIES
Desi n Information
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43 OF
Inside do 70 of
Outside db
Insidedb
96
75
OF
OF
OF
Design TD 27 OF
Design TD
Daily rang9
21
L
%
Relative humidity
50
Moisture difference
74
gr/lb
Heating Summary
Structure 24075 Btuh
Ducts 1204 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Stuh
Equipment load 25279 Btuh
Infiltration
Method Simplified
Construction quality Avers O
Fireplaces
Hea132g Co 1328
Area (ft2
8
Volume �ft')
15272 15272
Air changes/hour
0,3�5 D'18
Equiv. A F (cfm)
45
Heating Equipment Summary
Make CARRIER
Trade CARRIER
Model CH16NA048
AHRI ref 202362381
Efficiencyy
Heating input
Heating output.
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
capacity balance point = 12 OF
9 HSPF
46500
Btuh @ 47°F
1600
cfm
0.063
cfm/Btuh
0
in H2O
Backup:
Input = 5 kW, Output = 17061 Btuh, 100 AFUE
Sensible Cooling Equipment Load Sizing
Structure
33933
Stuh
Ducts
3393
Btuh
Central vent (0 cfm)
0
Stuh
(none)
Blower
2468
Btuh
Use manufacturer's data n
Rate/swing multiplier 1.01
Equipment sensible load 40153 Btuh
Latent Cooling Equipment Load Sizing
Structure
3053
Btuh
Ducts
2073
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
5126
Btuh
Equipment Total Load San+Lat)
Req. total capacity at 0.1`0 SHR
45278
4.8
Stuh
ton
Cooling Equipment Summary
Make CARRIER
Trade CARRIER
Cond CH16NA048
Coil FX4DNB061L
AHRI ref 202362381
Efficiency 13.0 EER, 16 SEER
Sensible cooling
33500
Btuh
Latent cooling
14400
Btuh
Total cooling
48000
Btuh
Actual air flow
1600
cfm
Air flow factor
0.D43
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrlµtsw t^ 2021-M•Y tO 11:agI
--„JPw..-r+-a-, p�gh(Sui1a® U�IVBRaI 101a 19.D20 ft6U0304g Page
leck c:t CtCM-,DIAMND-SNoS31-HL-34.NP Calo, MJ8 Front Door races: W
Load Short Form Job: CM-DIAMND-SNDS-31-...
l tti htsoft' Date: 5-9.21
ZONE #3
6y:
CONNIVS E-CALCS
Pwne: 561-748-7745
Project• •
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT 31, 8208 S OCEAN DR, CITY OF PT ST LUCIE
Htg Clg Infiltration
Outside db ('F) 43 96 Method Simplified
Inside db (°F) 70 75 Construction quality Average
Design TD ('F) 27 21 Fireplaces 0
Daily range L
Inside humidity (%) 50 50
Moisture difference (gr/lb) 22 74
HEATING EQUIPMENT
Make
CARRIER
Trade
CARRIER
Model
CH16NAM
AHRI ref
202362381
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 12 OF
Backup,'-
9 HSPF
46500
Btuh @ 47°F
26
OF
1600
cfm
0.063
cfm/Btuh
o
in H2O
COOLING EQUIPMENT
Make CARRIER
Trade CARRIER
Cond CH16NA048
Coil FX40NB061L
AHRI ref 202362381
Efficiency 13.0 EER,
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
33600
Btuh
14400
Btuh
48000
Btuh
1600
ofm
0,043
cfm/Btuh
0
in H2O
0.89
Inp_W MADiA
uu,1uislpL
ROOM NAME
Area
tg load
(BtuOFC/LNG,BDS23,ST
Cig load
cfmAVF
CIgnAVF
1326
25279
37327
1600
1600
ZONE #t3 d
Other equip loads
Equip. @ 1,01 RSM
Latent cooling
1328
25279
0
37327
2468
40153
5126
1600
1600
o997G
aA77A
IWO
1600
I V IHL 5
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed,
P19soR 2021-Mey-10 t1:gI
W
,,,,,,,., tit_,,,,,,,., Right-9u4e® Unlverea12019 19.0.20 RSUo3D49 Page
r41�t�I� C:1ec\CM-DIAMND-SND331-HL-34.mp Cale-MJe Front Doorfacea: W
` 9t Project Summary
ZONE #4
CONNIE'S E-CALCS
Phm : 661-748-7745
Job: CM-0IAMND-8ND8-31-...
Date: 5.9-21
By:
For: VENATION HOLDINGS LLC
DIAMOND SANDS, LOT 31, 8208 S OCEAN DR, CITY OF PT ST LUCIE
Notes: PHOENIX HOMES
Design Information
Weather: Vero Beach Municipal AP, FL, US
Winter Design Conditions
Outside db 43 or
Inside db 70 OF
Design TO 27 OF
Heating Summary
Structure
18584
Stuh
0
Btuh
CCentral vent (0 cfm)
(none)
Humidification
0
Btuh
Equipment
Btuh
load
18584
Infiltration
Method
Construction quality
Fireplaces
Area (ft'
Volume (fta)
Air changes/hour
Equiv. AVF (cfm)
Simplified
Average
0
He lin 1026
Co 1p26
12312
12312
D
D
58
29
Heating Equipment Summary
Make CARRIER
Trade CARRIER
Model CH16NA030
AHRI ref 202362113
Efficiency
Heating input
Heating output
Temperature rise
Actual air floe+
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 21 OF
Backup•
9 HSPF
28600
tuh @ 47°F
27
OF
973
cfm
0.052
cfm/Btuh
0
in H2O
Input = 5 kW, Output = 17061 Btuh, 100 AFUE
Summer Design Conditions
Outside db
96
OF
Inside db
75
OF
Design TngDe
21
OF
Relative humidity
50
Moisture difference
74
gr/Ib
Sensible Cooling Equipment Load Sizing
Structure
22478
Btuh
Ducts
0
Stu
Central vent (0 cfm)
0
Stuh
(none)
ee)
Blower
3410
Btuh
Use manufacturer's data n
Rate/swinngq multipplier 1.01
Equipme,n sensible load 26121 Stuh
Latent Cooling Equipment Load Sizing
Structure 1849 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Equipment latent load 1849 Btuh
Equipment Total Load�Sen+Lat) 27970 Btuh
Reg. total capacity at 0. 0 SHR 3.1 ton
Cooling Equipment Summary
Make CARRIER
Trade CARRIER
Cond CH16NA030
Coil FX4DNF037L
AHRI ref 202362113
Efficiency
13.0 EER, 16 SEER
Sensible cooling
20440
Stuh
Latent cooling
8760
Btuh
Total cooling
29200
Stuh
Actual air flow
973
cfm
Air flog factor
0.043
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat
ratio 0.93
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-r{rF wri! htsM't• 2021-May-10 11:09:50
Right-SUIte® Univerx9l 201919.0.20 RSUM049 Page 2
A�,CI\a°\CM-DIAMND-SND831-HL-34.mp Laic=MJ$ Front Door tacee: W
POone; $451-748-7749
Load Short Form Job: C1101•DIAMND-ENDS-31-..,
BONE #4 Date: 5-9-21
CONNIE'S E-CALCS
?-'roject Information
For: VENATION HOLDINGS H C
DIAMOND SANDS, LOT-31, 8208 $ OCEAN DR, CITY OF PT ST LUCIE
Htg
Ctg Infiltradon
Outside db (°F)
43
96 Method Simplified
Inside db (°F)
70
75 Construction quality Average
Design TD (°F)
27
21 Fireplaces 0
Daily range
L
Inside humidity (%)
50
50
Moisture difference (gr/lb)
22
74
HEATING EQUIPMENT
Make
CARRIER
Trade
CARRIER
Model
CH16NA030
AHRI ref
202362113
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 21 OF
Backup:
w 17OM616
9 HSPF
28600
Btuh @ 47°F
27
OF
973
cfm
0.052
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make CARRIER
Trade CARRIER
Cond CH16NA030
Coil FX4DNF037L
AHRI ref 202362113
Efficiency 13,0 EER,
Sensible cooling
Latent Cooling
Total coaling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
16 SEER
20440
Btuh
8760
Btuh
29200
Btuh
973
cfm
0,043
cfm/Btuh
0
in H2O
0.93
ROOM NAME
Area
Htg load
Clg load
HtgAVF
CIgAVF
(W)
(Btuh)
(Btuh)
(cfm)
(cfm)
MASTER SUITE
1026
1B594
22478
973
973
ZONE #4 d
1026
18584
22478
973
973
Other equip loads
0
3410
Equip. @ 1.01 RSM
26121
Latent cooling
1849
T/1TA1 C
1110G
40GOA
'SY(1011
[l90
1190
V IIILV loco �VVVT �/viV V/u a/V,
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-May-10 11:08: 50
Right -Suite® Unlvenal 201919.0,20 R$U03049 Paw 2
C:\aC\CM-DIAMNO-SNOS-3I-HL-341up Cole a MJB From Boor WO±: W