HomeMy WebLinkAboutDesign Load Compliancei_5__ - =-__ - '11
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
P oject Name: Custom Home, Lot 31
Project Address, 8208 S Ocean Dr, Jensen Beach
Permit #:
INSTRUCTIONS FOR USE:
Diamond Sands
Occupancy Type: Construction Type:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
RESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) ILO
1, DESIGN CODE: Florida 2020 Code Sixth Edition with 2020 Supplements using ASCE�
2Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
31 Risk Category: I X II _III IV Exposure Category:
X D
4� Design Wind Velocity 170 mph ASD X LRFD End Zone Width: 8 ft
5 Mean Roof Height 39'- 11 of ft Roof Pitch: 4 :12 Parapet: none ft
6, Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: See Zone 2: plans Zone 3: -- Zone 4:------ Zone 5:------ Garage: -----
7 Design Loads: Floor: 40 PSF Roof/Dead: 24 PSF Roof/Live: 30 Balcony: 50 PSF
Dock: N/A PSF Deck: 50 PSF Stairs: 50 PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9, Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:60K piles �K Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I, also ce[iify that structural elements depicted on these plans provide adequate resistance to the design
forces Speciftd:
Robert E Agsten III
Print Name Cert # & Co. Cert Auth.
/A l/�/�'' , Agsten Engineering, Inc.
l 'L 1
sigh %e, bate;OftSBal
Revised Ii0o Y//,Q AL
3000 Florida Blvd., #206, Delray Beach, FL 33483
Company Name & Address