Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISED A200 FLOOR PLAN
OPEN ABOVE ELEVATORHB C.H. GARAGE 12'-6" LOWER LEVEL EL. 9.00' NAVD UP 22R @ 6.8"=12'-6" FLR-FLR. 8.83' NAVD 6.83 NAVD 7.00' NAVD 2" SLOPE 6.83' NAVD POOL EQ POOL EQUIPMENT PAN 'A'PAN 'B'PAN 'P' C.H. FOYER 10'-6" 9'0" CLG. 10'-6" CLG. GARAGE LEVEL EL. 7.17' NAVD 4 FLOOD VENTS EA. VENT 200aSF. AS PER MANUF. SPECS., SEE 2/A200a FOR DETAIL & CALCULATIONS 1 FLOOD VENTS EA. VENT 200aSF. AS PER MANUF. SPECS., SEE 2/A200a FOR DETAIL & CALCULATIONS STORAGE LEVEL EL. 7.5' NAVDCOLUMN 7.5' NAVD OUTDOOR SHOWER/ DOG WASH 22R @7.6"=14'-0"UPC.H. UNFINISHED NON HABITABLE 10'-6" EXPOSED SLAB 12'-2" C.H. STUCCO CLG. BOTTOM @ 10'-6" T&G CLG. STUCCO CLG. BOTTOM @ 10'-6" STUCCO CLG. BOTTOM @ 10'-6" 1 A303 1 A303 2 A303 2 A303 TO MAIN FLOOR SWITCHHBCUCONDENSER1 CUCONDENSER2CUCONDENSER3CUCONDENSER4SETBACK LINE SETBACK LINE NOTES: THIS PROJECT IS DESIGNED IN COMPLIANCE WITH FBC 2020 7th EDITION SECTION R322 SEE WALL LEGEND FOR FRANGIBLE WALLS SEE DETAIL 14 ON SHEET A803 FOR INTERIOR FRANGIBLE WALL CONSTRUCTION DETAIL. STORAGE AREA (NON HABITABLE) POURED REINFORCED CONCRETE COLUMN (TYP.) POURED REINFORCED CONCRETE COLUMN (TYP.) NOTE: MOUNT EQUIPMENT ON THIS LEVEL TO STRUCTURAL COLUMNS, AND NON-FRANGIBLE WALLS (SEE SHEET A200a FOR FRANGIBLE WALL LEGEND). DUE TO THE 24 DEGREE ANGLE TO SHORE, ALL INTERIOR FRAME WALLS THIS LEVEL TO BE FRANGIBLE STAIRS RAILING STAIRS RAILING 3 FLOOD VENTS EA. VENT 200aSF. AS PER MANUF. SPECS., SEE 2/A200a FOR DETAIL & CALCULATIONS 3 FLOOD VENTS EA. VENT 200aSF. AS PER MANUF. SPECS., SEE 2/A200a FOR DETAIL & CALCULATIONS 3 FLOOD VENTS EA. VENT 200aSF. AS PER MANUF. SPECS., SEE 2/A200a FOR DETAIL & CALCULATIONS 1 1 1 LOWER LEVEL WINDOW SCHEDULE Number WIDTH HEIGHT SIZE TYPE HEAD HT. EL.NOTES FLOOD VENT CALCULATIONS GARAGE 1,500 S.F. VENT (as per manuf. specs.)200 S.F. TOTAL 8 VENTS MINIMUM = 1,600SF CMU WALL 8"12" MAX.8X16 FLOOD VENT BY "SMART VENT" MODEL #1540-520 PROPOSED GRADE GARAGE FIN. FLOOR UNFINISHED AREA 962 S.F. VENT (as per manuf. specs.)200 S.F. TOTAL 5 VENTS MINIMUM = 1,000SF 1 2 LOWER LEVEL EXT. DOOR SCHEDULE Number WIDTH HEIGHT SIZE TYPE Fire Rating NOTES LOWER LEVEL INTERIOR DOOR SCHEDULE Number WIDTH HEIGHT SIZE TYPE FIRE RATING NOTES 06.29.21CUSTOM RESIDENCEDIAMOND SANDS - LOT 31JENSEN BEACH, FLALL IDEAS, DESIGNS, ARRANGEMENTS, & PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, & THE PROPERTY OF THIS OFFICE. & WERE CREATED, EVOLVED, & DEVELOPED FOR USE ON, & IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS, OR PLANS SHALL BE USED BY, OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF RANDALL E. STOFFT, ARCHITECTS, P.A. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS. CONTRACTORS SHALL VERIFY & BE RESPONSIBLE FOR ALL DIMENSIONS & CONDITIONS ON THE JOB, & THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED. © 2018. ALL RIGHTS RESERVED RANDALL STOFFT ARCHITECTS P.A. Job No. 20110080DPERMIT SETPERMIT SET CML 06.29.21 1 BLDG. DEPT. COMMENTS KPR 08.23.21 DEP SET CML 03.02.21 1/4"=1'-0" LOWER LEVEL NOTED PLAN1 3/4"=1'-0" FLOOD VENT DETAIL2 A200a Y:\DelrayProjects\!RESIDENTIAL\2010080D-LOT 31 DIMOND SANDS SPEC\SheetFiles\LOT 31_A200.dwg, 8/23/2021 4:00:40 PM