HomeMy WebLinkAboutENGINEERINGTx2" GALVANIZED WASHER WITH Y" NUT EYES BOLTED TOGETHER WITH y"x2" BOLT & NUT WITH (2) 2"x2" GALVANIZED WASHERS (2,000LB SHEAR CAPACITY) n'x 3" (400 LB) CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) Y"THREADED ROD OPTIONAL FOR "HIGH SET" & COUPLER SIMPSON A-24 CLIP OR EQUAL SHED WITH SKID ANCHORED TO CONCRETE 1/2"x5" (400 LB) CONCRETE WEDGE ANCHOR INTO SLAB THRU 2"x4" P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) ITE "MIN. IC SLAB BY OTHERS Id__ - THROUGH LOCAL CODES CONCRETE SLAB BY OTHERS AND JURISDICTION THROUGH LOCAL CODES AND JURISDICTION SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE,HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED - THRU THE 2"X4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT A'NO FLOOR' OPTION, -ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM -, PLATE. a 0 U Z C7 LU W U) Z g a 3 0 0 0 N It a 0 iO TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPAC'G 20'-0" 400 T-6" 13'-8" 280 T-6" 111-8" 240 T-6" 10'-0" 200 T-6" 8'-0" 160 T-6- 6'-0" 120 S-6" NOTCH OR COUNTERSINK BOLT THRU 2"x4" BOTTOM PLATE 1/2" THREADED ROD OPTIONAL FOR "HIGH SET" 2"x4" BOTTOM PLATE NAILED TO 2"x6" P.T. BASE _7 71 4" MIN. 9-4 SHED WITH'NO FLOOR' OPTION' ANCHORED TO CONCRETE 1/2" COUPLE 1/2"x12" FORGED EYEBOL EYES BOLTED TOGETHER W/ BOLT & NUT WITH (2)2"x2" GALV/ WASHERS (2,000LB SHEAR CAP 30" EARTH A (SEE TABLE 4 SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) k x4} BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO - - FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 2 SKID RUNNER SPACING' SHED WIDTH - X1 X2 X3 13'-8" 1'-102" 1'-102" 1'-14, 111-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-10" - 81-0" 9" 6'-6" - 6'-0" 10" 51" - ' VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 1 V-8" AND 13'-8" WIDE SHEDS ONLY. ' LUAU WIDTH OF UPLIFT ON RUNNER NOTES: 1. PAD SPACING IS END TO CENTER OF PAD 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING TABLE 3A PAD TYPES TYPE PAD DIMS MAX LOAD' MATERIAL I 2"x8"X16" 1778 LBS CONC. BEUI7XMUA1rrT- CEMENT-AND SAND MIX II 4"x8"X16" 3500 LBS CONC. BLOCK OUT= CEMENT AND SAND MIX III 16"X16" 3950 LBS ABS PLASTIC PADS IV 8"X8"X16" 1900 LBS CONC. BLOC QUALITY CEMENT AND SAND MIX ' BASED ON 20DO PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL) NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON I V-8" AND 13'-8" WIDE SHEDS ONLY. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS WASHER 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE i HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). j LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR GRADE ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. 61?X- /'- TY.PFA-11111I OR IV PAID WITH CODE INFORMATION" " CODE VERSION FBIC '7TH EDITION (2020);'ASCE T 16 �' MANUFACTURER SUFERI(3FFSHEDS' BUILDING TYPE MANUF. SHED CONSTRUCTION V-B CODE VERSION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NO. OF STORIES 1 BASIC WIND SPEED 180 MPH (VULT) EXPOSURE C ENCLOSURE ENCLOSED INTERNAL PRESSURE COEF. +/- 0.18 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10 PSF ROOF LIVE LOAD 20 PSF OR 300LBS FLOOR DEAD LOAD 8 PSF FLOOR LIVE LOAD 75 PSF / 125 PSF "R" RATING (WALL, FLOOR, ROOF) NIA MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE LESS THAN 720 S.F. SHED STRUCTURE FOR: SUPERIOR SHEDS (877)439-7433 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 ............................... MODULAR PLANS DESIGN, CO. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW' UPLIFT (PLF) END ANCHOR" MAX. INTERIOR SPACING'" 13'-8" 7.00 243 0'-0" TO T-0"> 10_0�" A 1 V-8" � 6 00 208 ^_ 0,-0,' TO T-0"- 10'-0" 5.00 174 0'-0" TO T-0" - 10'-0" 8'-0" 4.00 138 0'-0" TO T-0" 10'-0" 6'-0" 3.00 104 0'-0" TO T-0" TABLE 4B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW' UPLIFT (PLF) END ANCHOR" IMAX. INTERIOR SPACING" 20'-0" 10.00 400 0'-0" TO T-0" 1 6-0- LOAD WIDTH UPLIFT ON RUNNER LOCATION FROM END WALL OF AUGER ANCHOR MAXIMUM SPACING BETWEEN ANCHORS IOTES 1 I. ANCHOR SPACING IS DESIGNED AS PER ASCE-7 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER 3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. I -ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" N4.ETWEEN ANCHORS. NCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN XISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE O THE SIDE AS POSSIBLE. GENERAL NOTES: ...oR..... 1. FOUNDATION PLANS ARE NOT PART OF THIS �`�: `�censE •so PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION = FSSONA .. 1015.22 3. REFER TO TIE -DOWN DETAILS FOR PROPER Digitally signed b INSTALLATION REQUIREMENTS TO MEET CODE. g Y 9 Y �-r Julio Orbegoso File copy Date:50211.022.0011 RECEIVED SEP 13 2021 C-O;NSUNTI1,N6i N61,NiEER` St. Lucie County J . LIO. OO RBE=GOO S® Perm, Taint FLQRI DA _PE LIGENSE 387:69 MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SUI1E 105 OFFICE: 863.688.1054 LAKELAND, FLORIDA FAX 863.688.7118 33813 COLE@MODULARPLANSCO.COM DATE: 01-22-2021 DRAWN: R.L.G. JOB: SS FOUNDATION SHEET NO. Al GENERALNOTES 1. Foundation plans are not part of this plan set and are governed by local jurisdiction. 2. Buildings are approved for residential lawn storage only 3. This building is exempt from the FECC per sections RI 01.4.2.4, R402.1. 4. Refer to tie down details for proper installation requirements to meet code. 5. All lumber for construction will be #2 SYP except as noted. 6. Gutters shall be site installed per the local authority having Jurisdiction and permitting requirements. 7. All windows and doors to meet the minimum specifications per the approved plans and the Florida Building Code. 8. In accordance with FBC 1609.1.2, "Storage sheds that are not designed for human habitation and that have a floor area of 720 square feet or less are not required to comply with the mandatory windborne debris impact standards of this code". 9. In accordance with FBC 1010.1.1, exception (10.) Buildings that are 400 sq-ft or less and that are intended for use in conjunction with one- and two-family residences are not subject to the door height and width requirements of this code. Structures 400 sq-ft or more shall have an 80" minimum door. 10. In accordance with Florida Statute 553.80 (1)d, lawn storage buildings and storage sheds bearing the insignia of approval of the department are not subject to 553.842 (Florida product approvals) but shall meet the design wind load requirements of the 2020 FBC 7th edition. 11. Flat metal straps can be bent around structural members of wall studs, trusses, chords, etc. To help secure these members, provided that the added bend does not interfere with any of the existing breaks/bends in the strap. 12. As per FBC section 1626.1 exception (f): storage sheds that are not designed for human habitation and that have a floor area of less than 720 square feet or less are not required to comply with the mandatory windborne debris impact standards of this code. 13. Components/Cladding are in compliance with the 2020 FBC 7th Edition. 14. Sheds located in flood hazard areas must comply with the local flood zone regulations. 15. If a wall is framed for future HVAC units that shall be approved by the AHJ and shall comply with local requirements for permitting. 16. Windows and doors installed by the customer that shall be approved by the AHJ and shall comply with local requirements for permitting. 17. HVHZ components for sheds require that installation per manufacturer's instructions. Z a IL 0 z c7 co w 0 Z Z g a 5 0 N N a 0 0 O, U �T_'_TOP LINE ENGINEERING._ LLC �L STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 2323 S. VOLUSIA AVENUE ORANGE CITY, FLORIDA 32763 (877) 439-7433 LISTING AGENCY APPROVAL: TOP LINE ENGINEERING, LLC. BUILDING CODE RESIDENTIAL CODE ELECTRICAL CODE BUILDING TYPE MANUFACTURER AGENCY AGENCY PLAN NUMBER CONSTRUCTION TYPE FIRE PROTECTION FIRE SUPPRESSION SYSTEM OCCUPANCY ALLOWABLE # OF STORIES WIND VELOCITY FIRE RATING OF EXTERIOR WALLS FLOOR LIVE LOAD - STANDARD FLOOR LIVE LOAD - OPTIONAL FLOOR DEAD LOAD ROOF LIVE LOAD ROOF DEAD LOAD "R" RATING OF FLOOR, WALL,&ROOF MODULES PER BUILDING SQUARE FOOTAGE HURRICANE PROTECTION USAGE HURRICANE SHELTER USAGE HVHZ APPROVED FBC, 7TH EDITION (2020) FRBC, 7TH EDITION (2020) 2017 NATIONAL ELECTRICAL CODE RESIDENTIAL LAWN STORAGE SHED SUPERIOR SHEDS, LLC TOP LINE ENGINEERING, LLC BUNG-20-HVHZ V-B NO NO UTILITY 1 170 MPH, EXPOSURE C 0 75 PSF 125 PSF 10 PSF 30 PSF 10 PSF N/A 1 719 SQ/FT. MAX. NO NO YES TOP LINE ENGINEERING, LLC DESIGN PRESSURES DOORS (by EAGAN) +/-20 PSF WINDOWS (by CROFT) +/-40.10 PSF D/P INFO PROVIDED BY MANUFACTURER Digitally Phase r ote.Any.questions regarc►tng lgcal•permifting should be directed to .the /Manufacturer: 'The ....."„ �o oReF� -,, signed by Julio Manufactutei's contact informaifon .can'be found in the tifle:bfock:of the plans. Orbegoso - APPROVED FOR HVHZ NoDate: A°ass;oNA� C,-15093609of"""""' MODULAR -05'00' PLANS DESIGN, CO. STRUCTURAL LOAD LIMITATIONS WIND LOAD CRITERIA 1. 132 Vasd/170 Vult WIND SPEED (MPH) 2. 1 RISK CATEGORY 3. II BUILDING CATEGORY 4. ENCLOSED ENCLOSURE CLASSIFICATION 5. GCpI = 0.18 INTERNAL PRESSURE COEFFICIENT 5. C EXPOSURE FACTOR 6. 0.85 WIND DIRECTIONALITY FACTOR (Kd) 7. 0.85 GUST RESPONSE FACTOR (Gh) 8. Pr='-93.0 PSF MAIN FRAME STRUCTURE OVERTURNING LOAD 9. COMPONENT & CLADDING LOAD (ROOF) Pr = ZONE 1: -35.63 PSF, ZONE 2: -35.63 PSF, ZONE 3: -65.26 PSF (WALL) PW = ZONE 4: -39.14 PSF, ZONE 5: 46.89 PSF 10. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT. SEISMIC LOAD: N/A FLOOD LOAD: THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL. SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH THE LOCAL FLOOD ZONE REGULATIONS. DRAWING INDEX C1 COVER SHEET Al FLOOR PLAN A2 SIDEWALL FRAMING A3 FLOOR FRAMING A4 ROOF FRAMING A5 CROSS SECTIONS A6 ENDWALL FRAMING A7 SCHEDULES BUNGALOW SHED - HVHZ MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE, SURE 105 OFFICE 863.688.1054 LAKELAND, FLORIDA FAX .68 8638.7118 33813 COLE@MODULARPVWSCO.COM CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 1U2I-U2-Ub IUF LINL LNUINLLKINU AI-1'KUV/HL FLAN 1# bU N(3-HVHZ-2U ` HVHL AI'F'KUVtU z z a 0 z c� w CD 3 a 5 0 N N c� If r 0 U O CEILING J-BOX I I I LINE SINGLE POLE NtUIKAL 15 AMP G.F.I. SWITCH OUTLET ELECTRICAL NOTES & OPTIONS: - AS PER NEX ARTICLE 330.30(B) SECURING OF MC TYPE CABLE. UNLESS OTHERWISE PROVIDED, CABLES SHALL BE SECURED AT INTERVALS NOT EXCEEDING 6FT. CABLES CONTAINING FOUR OR FEWER CONDUCTORS SIZED NO LARGER THAN 10 AWG SHALL BE SECURED WITHIN 12 IN. OF EVERY BOX, CABINET, FITTING, OR OTHER CABLE TERMINATION. - ALL WIRING SHALL BE 14 GAUGE 3-WIRE MC CABLE. - ENCASE IN ALL METAL BOXES. MAXIMUM NO. OF OUTLETS: 7 MAXIMUM NO. OF LIGHTS: 8 ELECTRICAL WIRING DIAGRAM SCALE: NOT TO SCALE NOTE: 1. MIN. GRADE STUDS: 2"X4" STUDS TO BE Fb = 1200 PSI OR GREATER 2. MIN. ROOF SHEATHING: 29GA CORRUGATED METAL 3. MIN. FLOOR SHEATHING: %4' PLYWOOD 4. MIN. WALL SHEATHING: D4 ALUMINUM SIDING NOTE: 23" SECTIONS OF 29GA CORRUGATED METAL SIDING FASTENED W/ %4" #8 HEX HEAD w/ WASHER SELF TAPPING SCREWS @ 6" ON EDGE & 12" IN FIELD. NOTE: SHOWN IS THE 10'-0" x 20'-0" -__STOP LINE ENGINEERING.. LLC STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 � \ Digitally signed O RBFG O '�,,� .O�O�� by Julio N0.38769 Orbegoso * �= Date: ��0 STATE OF C(/�� =,;�F ' .�CORIDP.•' G\�, 2021.02.09 �O"11110\ 15:10:26-05'00' SHED OVERALL LENGTH (MAX. 40'-0") FLOOR PLAN SCALE: 3/8" = V-0" NOTE: SHEDS TO HAVE A MAXIMUM OF 5 DOORS AND 10 WINDOWS CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 ' MODULAR PLANS DESIGN, CO. MODULAR o �Ro SURE,D5 OFFIMFAXBB6S:�1,�ta8 PLANS DESIGN, CO. 33818 COLE@MODUTARPUUJSCO.COM 2U21-U2-Ub IUP LINE ENGINEEKING AF'I KUVAL PLAN 4 BUNG-HVHZ-2U *** HVHZ APPKUVED ENDWALL DOOR & WINDOW F-O" WIDE OR LESS SCALE: NTS 2"X4" SYP#2 STUDS @ 24" O.C. 2"X4"X60" SYP#2 SISTER STL ATTACHED W/ 10d COMMON NAILS @ 4" O.C. ,11oRB Digitally signed �,JV�O LICENSE G�`j1O by Julio = N.. 38769 Orbe oso �'•.- :gz Date: ' Q STATE OF �FS'•.ORIDP..aG\�, 2021.02.09 SOryp� 15:10:50-05-00' a D. 0 z c� Tn w 0 Tn z s a D 0 0 0 0 0 N x EL V O OPTIONAL HYDROVENT DETAIL SCALE: NTS 3"X6" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 BOTTOM 4"X4" SYP #2 HEADER 2"X4" SYP #2 JACK STUD 2"X4"SYP #2 KING STUD 4"X4" HEADER DETAIL SCALE: NTS JD DETAIL (6" MITEK MT20 _ )R EQUIVALENT .BETWEEN NT IS SECURED kS PER INSTRUCTIONS 0 in I 2, O.C. - • ROOF il oB." X*X��l v �•'io -,SEE HENN DETAIL ' I� FLOO DECKING @ O.C. STUDS TI • ,D LENGTH (MAX. 40 ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING W/ SIMPSON LTS16 STRAP w/ 5 -10d NAILS ON TOP INTO STUD, SECURING INTO RIM JOIST ON BOTTOM W/ 5-10d NAILS (TYPICAL) A SIDEWALL FRAMING SCALE: 3/8' = 1'-0" NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. OR)O B4FILLER OR (l'WOOD SUP[ 2323 S. VOLUSIP 2 KING STUD SIDEWALL DOOR & WINDOW (TYP) SCALE: NTS MODULAR PLANS DESIGN, CO. L BUNGALOW SHE - HVHZ MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE. SUITE 105 OFFICE: 863.668.1054 LAKELAND, FLORIDA FA): .fi8 8638.7118 33813 COLEQMODUTARPUWSCO.COM — ENDWALL SIMPSON LTS12 @ ALL TRUSS _TO HEADER CONNECTIONS. USE MIN (5) 10d NAIL INTO TRUSS & (5) 10d NAILS INTO HEADER. P LIRE ENGINEERING, CLC Saitt:CNFAL ECIGINf . William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 2"X4" SYP#2 SOLE PLATE 2"X6" SYP#2 PERIMETER WALL SHEATHING OPTIONS: - %s' OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM - D4 ALUMINUM SIDING -Y2" OR 8" T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 7ng1-nq-nR TC)P I INF FNC=7INFFRINC-, APPROVAI PLAN 9 RIINC-,-HVH7-gn *** HVH7 APPRC)VFI) a a 0 0 U z c9 w z z a a D 0 0 M C9 o0 U LWI SKID RUNNER SPACING* WIDTHS 6'-0" 8'-0" 10'-0" 11'-8" 13'-811 A 0'-101, 0'-91, 1'-7" 2'-8" V-10.5" B 5111 6'-6" 6'-10" 6'-4" V-10.5" C - - - - V-10.5" *VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SKIDS. TOP LINE ENGINEERING, LLC L STRUCTURAL ENIGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 m FLOOR SHEATHING 2-1/2" X 1/2" THRU-BOLT HIEAVY ANGLE Vv� ,-" P,T. FLOOR JOISTS 4"X4" P.T. SKID SHED OVERALL LENGTH (MAX. 40'-0") - BLOCK Li ,IO�;,IOIO'��OIi I10I0�`�IO�'IO ■ FLOOR O.C. OPTIONAL . o.c. Typ SEE TABLE SPACING JOISTS 4"X4 W/ 2 FOR P. 1. H24 OR QUANTITY SKIDS ATTACHED EQUIV. ' 1 1/2" NOTCH 2"X6" PERIMETER RAIL FLOOR FRAMING PLAN SCALE: 3/8" = V-0" Digitally signed O RBFG ,J�\•' \CENSF �lrO% by Julio No.38769 _ Orbegos0 �� Date: ��O STATE OF ��� -,Fss•.�oR�eP••�G`,., 2021.02.09 ,/11NAL/Ml\���` 15:11:10-05'00' BUNGALOW SHED - HVHZ 4-1/2" X 1/2"v r- THRU-BOLT 2323 S. VOLUSIP FLOOR JOIST TO SKID CONNECTION:w SCALE: NTS E ' 7 __i MODULAR PLANS DESIGN, CO. MODULAR PLANS DESIGN, CO. 202 DOM DRIVE., SURE 105 OFFICE: :63.668.1DS6 LAKELAND, FLORIDA FAX: 63.688.7118 33813 COLEQMODULARPLANSCO.COM w FLOOR SHEATHING: PLYWOOD P.T. PLYWOOD T&G - %4' P.T. T&G CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 2021-02-08 T0P I INF FNGINFFRING APPROVAI PLAN 4 RIINC,--FIVF17-2n *** 1-1VIH7 APPR(-)VFn } 2 0 U z C9 v, W 0 Z a 5 0 0 0 N 0 N H _ 0 U X u NOTE: INSTALLATION FOR ALL ROOF SHEATHING OPTIONS AS PER MANUFACTURER INSTRUCTIONS '' U^) co �Z) LLL r J >J ❑ Z w TOP LINE ENGINEEi2iNG. LLG STRUCTURAL ENGINEERS William E. Neary, III SIVIP-51, SNII-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 111Mr%AIAI i MrI �%Af rye Al I I.eIwn IRA r9/1rlrIR 1/� SHED LENGTH (MAX. 40'-0") ROOF FRAMING PLAN SCALE: 318" = V-0" I1111//, oRsFcc, Digitally signed _xCEN--j . SO by Julio No.38769 _ * * - Orbegoso 0 STATE OF �(/� Date: 2021.02.09 =,SS/F<ORID�G�?; 15:11:26-05'00' w CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 MODULAR PLANS DESIGN, CO. MODULAR LAE.-E.-I- OPCE3W8°;ND, A.:.1s�X PLANS DESIGN, CO. 33173 COLE@MDDLIARPLANSCO.COM "LUZ I-U1-Ub IUf' LINL LNVINttKINv At'f KUVHL FLAN 4 BUNU-HVH&:2U ` HVHL AFF'KUVED } 0 0 U Z U) W z J EL 5 ❑ 0 N 2 0 0 U rO\ MIN. 3:12 MAX. 8:12 2"X4" SYP#2 COLLAR TIE 2"X5" MITEK MT20 OR EQUIVALENT 2"X4" SYP #2 STUDS @ 24" O.C. 2"X4" SYP#2 BLOCKING 4"X4" P.T. SKID (CONT.) FLOOR DECKING (CONT.) FLOOR JOISTS @ 16" O.C. Ind SHED WIDTH (6'-0°, 8'-0", 10'-0", 1 V-8", 13'-8") A CROSS SECTION 'A' A5 SCALE: 3/8" = V-0" NOTE: 2"X4 STUDS TO BE Fb = 1200 PSI OR GREATER NOTE: WALL FRAMING MEMBERS ARE CONTINUOUS FROM FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ARE NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CLIPS SHALL BE FORMED OF GALVANIZED STEEL OF NOT LESS THAN 0.040" NOMINAL THICKNESS. 2"X4" ROOF TRUSSES @ 24" O.C. 2"X4" SOLE PLATE 2"X6" PERIMETER SISTER STUDS FOR 4'-0" LIFROM ENDWALL (TYP),, SISTER STUDS FOR 4'-0" TYPICAL STUD SPACING 24" O.C. MAX ,,FROM ENDWALL (TYP),, FLOOR TRUSSES @ 24" O.C. —I W. wa Ni1'>i>�> >� Rio°i✓ ini I� -MIN NI, SEE 7 DETAIL DECKING • SHED LENGTH (MAX. 40 ALL STUDS SECURED TO SOLE PLATE AND FLOOR FRAMING W/ SIMPSON LSTA12 STRAP w/ 5 -10d NAILS _j ON TOP INTO STUD, SECURING B INTO RIM JOIST ON BOTTOM A5 W/ 5-10d NAILS (TYPICAL) �E_TCTP LINE ENGINEERING, LLC �� STRUCTURAL ENGINEERS Y William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 WALL SHEATHING OPTIONS: -716" OSB OR SHEATHING EQUIV. OR BETTER - CORRUGATED ALUMINUM CROSS SECTION 'B' - D4 ALUMINUM SIDING SCALE: 3/8"=r-0"-Y2"OR5/"T1-11 SIDING - JAMES HARDIE PANEL OR EQUIV. - JAMES HARDIE HORIZ. SIDNG LAP OR EQUIV. - 29 GA CORRUGATED STEEL METAL SIDING (RUN ANY DIRECTION) - THERMO-PLY BLUE (0.135 THICK) W/ VINYL SIDING MODULAR PLANS DESIGN, CO. BUNGALOW SHED - HVHZ MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE.. SUITE 105 OFFICE: 863.688.1D54 LAKELAND, FLORIDA FA%: 863.688.7118 33813 COLE(OMODULARPLANSCO.COM — ENDWALL SIMPSON LTS12 @ ALL TRUSS .—TO HEADER CONNECTIONS. USE MIN (5) 10d NAIL INTO TRUSS 8L (5) 10d NAILS INTO HEADER. 2"X4" SOLE PLATE 2"X6" PERIMETER ......... ' __1 ocEniSi*­--?0':' No.38769 _ :�Q,C •.. STATE OF Digitally signed by Julio Orbegoso Date: 2021.02.09 15:11:50-05'00' CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA PE LICENSE #38769 2m-02-m TOP LINE ENGINEERING APPROVAL PLAN # BUNG-HVH7-90 *** HVH7 APPRC)VFF) MIN. 3:12 MAX. 8:12 #2 SJPDS @ 241 P.C. NG LE PIMTE SHED WIDTH (6'-0", 8'-0", 10'-0", 11'-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. 2"X5" MITEK MT20 OR EQUIVALENT A ENDWALL FRAMING A6 SCALE: 3/8" = T-0" TKO MXU ENGINEERING, LLG STRUCTURAL ENGtRIEERS William E. Neary, III SNIP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 SHED WIDTH (6'-0", 8'-0", 10'-0", 1 V-8", 13'-8") B ENDWALL FRAMING A6 SCALE: 3/8" = 1'-0" Digitally oRsFco,,,; signed by Julio \ Jar\CENSF' , Sl .0-= Orbegoso No.38769 * * = Date: -0 . STATE OF 2021.02.0 JQ i "tORIDP-.•' Io.....•' �� 15:12:06 .,, / / NA� `\ \ -05'00' " ROOF TRUSSES @ 24" O.C. (4" SYP #2 STUDS @ 24" O.C. ' SYP#2 BLOCKING 2"X4" SYP#2 SOLE PLATE (6" PERIMETER MIN. 3:12 MAX. 8:12 2"X5" MITEK MT20 OR EQUIVALENT (2) 2"X4" HEADER co w it MAX 36" SHED WIDTH (6'-0", 8'-0", 10'-0", 11'-8", 13'-8") 4"X4" P.T. SKIDS ATTACHED W/ SIMPSON H24 OR EQUIVALENT. SEE TABLE 2 FOR SPACING. B ENDWALL FRAMING A6 _ SCALE: 318" = 1'-0" CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 MODULAR PLANS DESIGN, CO. M O D U L AR 2°�,q (N�--EE.. AURE dos OFFICE: 8. 8.105FAX4 PLANS DESIGN, CO. 33873 COLEQMOOULARPLANSCO.COM 2U2I-U1-Ub IUF LINE ENGINEEKING P IffKUVAL t'LAN 4 BUNG-HVHZ-2U *** HVHZ APPROVED z z D¢. 0 0 U z cD a) U, CI 1n Z g D. 3 0 0 N (D 0 O U O SIMPSON STRONG DRIVE & STRAP - SD SCREW SCHDEULE PART#1DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H1 435 6-SD9x1.5' 4-SD9x1.5' H11Z 750 6-SD10x25' 6-SD!WZS" RAFTER H2A 495 5-SD9xl.5' 5-SD9xl.5' 2-SD9x1.S H2.5A 540 5-SD9x1.5' 5-SD9xl.5' H2.5 410 5-SD9x1S' 5-SD9x1.5' H2.5T 545 5-SD9xl.5' 5-SD9x1.5" H2A 495 7-SD9x1.5' 5-SD9xl.5" H3 320 4-SD9xl.5' 4-SD9x1.5' H4 280 4-SD9x1.5" 4-SD9x1 S' HS 415 4-SD9xl.5' 4-SD9xl.5' LTS-12 895 6-S139x1.5' 6-SD9xl.5' LTS-16 1075 6-SD9xl.5" 6-SD9x1.5" LTS-1B 1235 6-SD9xl.5" 6-SD9x1.5" LTS-20 1215 6-SD9xl.5" 6-SD9x1.50 MTS-12 895 7-SD9xl.5" 7-SD9x1.5" MTS-16 1075 7-SD9xl.5' 7-SD9xl.5" MTS-18 1255 7-SD9xl.5' 7-SD9xl.5' MTS-20 1255 7-SD9x1.5' 7-SD9xl.S PORCH PART#NESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 2-SD9x1S' 2-SD9xl.5- A23 4-SD9x1.5' 4-S09xl.5' A33 4-SD9xl.5- 4-SD9x1.5' BTM PLATE PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER LSTA-16 1235 7-SD9x1.5" 7-SD9x1.5' TIE -DOWNS PART#/DESC. UPLIFT WALL FASTENER FLOOR FASTENER 20GA.1-1/4' WIDE 4725 7-SD9x1.5" 518'x30-ANCHOR 1 4300 A ONLY NEEDED ON ALUMINUM SHEATHING WALLS. B. HEADERS OVER 6' SPAN. STRAP & FASTENER SCHEDULE' PART#/DESC. UPLIFT WALL FASTENER RAFTER FASTENER PLATE FASTENER H! 400 6-8dxl/5" 43d H11Z 750 6-16dx2.5" 6-16dx25' H2A 495 5-8dx7.5' 6•8dxl.5' 23dx1.5' H2.5A 535 - 5.8d 53d 1-125 410 53d 5.8d H2.5T 545 53d S-8d H2A 495 7-Bdx7.5' 53dc1.5" RAFI-ER(B) H3 320 43d 43d H4 235 4.8d 43d H5 265 43d 43d LTS-12 620 6-10dx1.5" 6-10dxl.5' LTS-16 620 6-10dx1S' 6-10dx1.5' LTS-18 620 6-10dx1.5' 6.10dxl.5" LTS-20 620 6-10dx1S' 6.10dx1 S' MTS-12 860 7-10dx1.5' 7-10dx1S' MTS-16 860 7-10dx1.5" 7-10dx1.S MTS-18 860 7-10dx1S' 7-10dxl.5' - MTS-20 860 7-10dxl.5" 7-10dx1S' PORCH PARTWDESC. UPLIFT COLUMN FASTENER RAFTER FASTENER A21 245 2-1Ddx1S' 2-1Ddx1.5E A23 585 4-10dxl.5' 4-1Ddx1S' A33 750 4-1Od 4-1Dd BTM PLATE PARTWDESC. UPLIFT WALL FASTENER FLOOR FASTENER LSTA-18 1110 7-10d 7-10d HEADER (D) PART#/DESC. UPLIFT STUD FASTENER HEADER FASTENER TP-35 N/R F3'x0.131' S'3'x0.131" HP40,41,807 25 S-3"x0.131' S'3'x0.131' TIE -DOWNS PARTI#DESC. LIFT J25 WALL FASTENER FLOOR FASTENER 20GA. 1-1/4' WIDE 7-10dxl.5' 5/8'x30"ANCHOR 4300 ' ALL STRAPS CAN BE SUBSTITUTED WITH AN EQUIVALENT BRAND MEETING SAME STRENGTHS. B. RAFTER TES TO STUD WALL TO BE AT EVERY CONNECTION FOR 24' O.C. & CAN EVERY OTHER FOR 16" O.C. BUT IS REQUIRED ON CORNERS AND STUDS ADJACENT TO CORNERS. C. ONLY NEEDED ON ALUMINUM & VINYL SHEATHING WALLS. D. HEADERS OVER 6'-O' SPAN. PRODUCT OPTIONS PRODUCT CAT. SUB. CATEGORY MANUFACTURER MODEL/DESC. STATE OF FL APPROVALP PANEL WALLS SIDING JAMES HARDIE 5116'CEDAR FLM 13223.1 PANEL WALLS SIDING JAMES HARDIE 5/18 STUCCO FLIk 132232 PANEL WALLS SIDING ADVANCED ALUM. 0.19GA FL#*23138.1 PANEL WALLS SIDING PLY GEM X FL#: - PANEL WALLS SIDING ADVANCEDALUM. X 111131.1 PANEL WALLS SIDING SIMPSON LUMBER X FL#: - EXTERIOR DOORS SWINGING EXT EAGAN E1HDL FLtk. 12820-R3 EXTERIOR DOORS SWINGING EXT CROFT 2009-LITE FL#: - WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 10853-R5 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 15527-RS WINDOWS SINGLE HUNG CROFT VERTSLIDER FL#: 16082-R3 WINDOWS SINGLE HUNG CROFT VERT SLIDER FL#: 16153-Rl WINDOWS HORIZ- SLIDER CROFT HORIL SLIDER FL#:27202 WINDOWS HORIZ- SLIDER CROFT HORIZ- SLIDER FLA 28822 WINDOWS HORIZ.SLIDER CROFT HORIZ- SLIDER FL#: 30848 - �J:"Your"•::O s bigitally signed by Julio Orbegoso Date: 2021.02.09 €15:13:28-05'00' FASTENING SCHEDULE (FBC TABLE 2304.10.1) CONNECTION FASTENING CONNECTION 24. BUILT-UP GIRDER AND BEAMS 20d COMMON (4-X 0.192-) AT 32" O.C. 3' XO.131 NAILSAT24'O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE 1. JOIST TO SILL OR GIRDER 3- 8d COMMON (21Y2- X 0.131� TOENAIL 3 - 3' 14 GAUGE STAPLES 3" 14 GAUGE STAPLES AT 24" O.C. 2-2Dd COMMON (4-X 0.192-) SIDES 2. BRINGING TO JOIST 2- 8d COMMON (2112- X 0.131") TOENAIL EACH END 2 - Btl COMMON (211T X 0.131-) 3 - 3' X 0.131' NAILS FACE NAIL AT ENDS AND AT 2 - 3' 14 GAUGE STAPLES 3 - 3" 14 GAUGE STAPLES EACH SPLICE 3. 1 .6' SUBFLOOR OR LESS TO EACH JOIST 2 - 8d COMMON (21/2-X 0.131-) FACE NAIL 25. 2' PLANKS 1 Sd COMMON (3112" X 0.162-) AT EACH BEARING 4. WIDER THAN 1"x6'SUBFLOOR TO EACH JOIST 3- 8d COMMON 2 1/2' X 0.131-) FACE NAIL 26. COLLAR TIE TO RAFTER 3-1Dd COMMON (3- X 0.148) MIN. 4 - 3" X 0.131' NAILS 4 - 3' 14 GAUGE STAPLES FACE NAIL 5. 2" SUBFLOOR TO JOIST OR GIRDER 2 -16d COMMON (3 1/2" X 0.162-) BLIND AND FACE NAIL 6. SOLE PLATE TO JOIST OR BLOCKING 16d (3 1/2" X 0.135-) AT 16" O.C. TYPICAL FACE NAIL 3' X 0.131 NAILS AT B' O.C. 27. JACK RAFTER TO HIP 3 - I Od COMMON (3- X 0.148) TOE NAIL 3' 14 GAUGE STAPLES AT 12" O.C. X 0.131 NAILS 4 - 3'14 SOLE PLATE TO JOIST AT BLOCKING AT 3 - 16d COMMON (3 112' X D.135") AT 16-O.C. 4 - 3" GAUGE STAPLES BRACED WALL PANEL 4 - 3" X 0.131' NAILS AT 16"O.C. BRACED WALL PANEL COMMON (3 X 0.162') 4 - 3" 14 GAUGE STAPLES AT 16" O.C. 3 - 36X 3 - 3" 14 GAUGE STAPLES FACE NAIL 7. TOP PLATE TO STUD 2 -16d COMMON (3 112' X 0.162") END NAIL 3 - 3' X 0.131' NAILS 28. ROOF RAFTER TO 2-BY RIDGE BEAM 2 -16d COMMON (31/2" X OAM TOE NAIL 3 - 3' 14 GAUGE STAPLES 3 - 3" X 0.131 NAILS 3 - 3" 14 GAUGE STAPLES 8. STUD TO SOLE PLATE 4-8tl COMMON (210X 0.131-)TOE NAIL 4 - 3' X 0.131 NAILS 3- 3'14 GAUGE STAPLES 2-16tl COMMONX0.162� 3 - 3' X 0.131' NAILSLS FACE NAIL 2 -16d COMMON (312' X 00.162-)3 - 3' 14 GAUGE STAPLES 3 - 3' X 0.131' NAILS 3 - 3' 14 GAUGE STAPLES END NAIL 29. JOIST TO BAND JOIST 3 - 16tl COMMON (312- X 0.135') FACE NAIL 4-3'X0.131'NAILS 4 - 3" 14 GAUGE STAPLES 9. DOUBLE STUDS 16d (3 112' X 0.135') AT 24.O.C. FACE NAIL 3' X 0.131 NAILS AT 8 O.C. 30. LEDGER STRIP 3 -16d COMMON (3 1/2- X 0.162-) FACE NAIL AT EACH JOINT 3' 14 GAUGE STAPLES AT 8' O.C. 4 - 3" X 0.131' NAILS 4 - 3" 14 GAUGE STAPLES 10. DOUBLE TOP PLATES 16d (3 112- X 0.135") AT 16' O.C. TYPICAL FACE NAIL 3" X 0.131 NAILS AT 8' O.C. 3' 14 GAUGE STAPLES AT 8" O.C. 31. WOOD STRUCTURAL PANELS AND 112" AND LESS 6d (C,I,O) PARTICLEBOARD (B) SUBFLOOR, ROOF AND L (N) DOUBLE TOP PLATES 8- 16d COMMON (3 112" X 0.135") AT 16-1 O.C. LAP SPLICE WALL SHEATHING (TO FRAMING) 3/4-16 GAUGE (0) 12-3"X0.131"NAILS AT 180.C. 19/32'T0314- Bd(D)OR 6d (E) 12 - 3" 14 GAUGE STAPLES AT 16" O.C. SINGLE FLOOR (COMBINATION SUBFLOOR- 2 318"X0.113" NAIL(6"O.C. 2' 16 GAUGE (P) EDGES AND _ RM 4' O.C. AT COMPONENT ANDEDIATE, 11. BLOCKING BETWEEN JOISTS OR RAFTERS 3 - Sd COMMON (2112-X 0.131E) TOENAIL TO TOP PLATE 3 - 3" X 0.131E NAILS UNDERLAYMENT TO 19/32" TO 3/4" FRAMING )) CLADDING EDGE STRIP #ZONE 3 3 - 3' 14 GAUGE STAPLES 1l18l8"OTO 1 1/4' 10d((D) OR.(D) 314"AND LESS 6d((C)) REFER TO FIG. 305-1 OF ASCE ( 7) 12 RIM JOIST TO TOP PLATE 8d COMMON (211T X 0.131-)AT 6"O.C. TOENAIL 3" X 0.131" NAILS AT 8 O.C. 718' TO 1- Bd(C) 3' 14 GAUGE STAPLES AT 8 O.C. 1 118 TO 1 1/4' 10d(D) OR Sd(D) 13. TOP PLATES, LAPS AND INTERSECTIONS 2 -16d COMMON (3 112' X 0.16n ' FACE NAIL 32 PANEL SIDING (f0 FRAMING) (Q) 112' OR LESS 6tl (F) 3-3 X O.131' NAILS 3 - 3' 14 GAUGE STAPLES 518" 8d(F) 14. CONTINUOUS HEADER, TWO PIECES 16d COMMON (3112' X 0.1 16' O.C. ALONG EDGE 33• FIBERBOARD SHEATHING (G,Q) 1/2-AND LESS N11 GAUGE ROOFING NAIL(H) 6d COMMON NAIL GAUGE I 15. CEILING JOISTS TO PLATE 3 -16d COMMON (3 1/2" X 0.131') TOE NAIL 5-3 ' X 0.131' NAILS 25132" STAPLE () NO. 11 GAUGE 6-O.C. EDGES AND INTERMEDIATE 3 - 3. 14 GAUGE STAPLES NAIL(H) Btl COMMON NAIL 112"NO. 16 G GAUGEE SSTATA') PLE (I) 16. RIM JOIST TO TOP PLATE 4 -8d COMMON (2 112-X 0.131- TOE NAIL 17. CEILING JOISTS, LAPS OVER PARTITIONS 3 -16d COMMON (3 112-X 0.1357) MIN. FACE NAIL 34. INTERIOR PANELING 1/4' (SEE TABLE 2308.10.4.1) 4 - 3" X 0.131' NAILS 6d(K) 6'O.C. EDGES AND INTERMEDIATE 4 - 3' 14 GAUGE STAPLES 18. CEILING JOISTS TO PARALLEL RAFTERS 3 -16d COMMON (3 112"X 0.135") MIN. FACE NAIL A COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED. B. NAILS SPACED AT 61NCHES ON CENTER ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 61NCHES AT (SEE TABLE 2308.10.4.1) 4 - 3' X 0.131' NAILS SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAGRAMS 4 - 3' 14 GAUGE STAPLES AND SHEAR WALLS, REFER TO SECTION 2305. NAILS FOR WALL SHETHING ARE PERMITTED TO BE COMMON, BOX OR CASING. C. COMMON OR DEFORMED SHANK (6d - 2 1/2'x 10d-3'x0.148). EDE ORMEI)6d 2 K•6d32 0?13 Btl0131 0' 31 Od 19. RAFTER TO PLATE 3 -Btl COMMON (2112' X 0.131' TOE NAIL LS 3 - 3' 143-3 0GAUGE STAPLES -- x0.1481". Y( ( ) ANT G. FASTENERS SPACED 3 NCIHES ON CENTER AT1EXfERIOR EDGESIAND 6 WCHE16 ON�CENTERAT•INTERM DIATE SU�PORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 6INCHES ON CENTER ON THE EDGES AND 121NCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED FOR NONSTRUCTURAL SHEATHING. 20. 1" DIAGONAL BRACE TO EACH STUD & PLATE 2 - 8d COMMON (2112-X 0.131-) FACE NAIL 2- 3' X 0.131' NAILS HSHEATHOINIGN-RESISTANT ROOFING NAILS WITH 7NS DIAMETER HEAD AND 1 12' LENGTH FOR 12' SHEATHING AND 1 314E LENGTH FOR 3 -3' 14 GAUGE STAPLES 1. CORROSION -RESISTANT STAPLES WITH NOMINAL 7118 CROWN OR 1" CROWN AND 1 1/4' LENGTH FOR 112 FOR 253Z" SHETHING PANEL SUPPORTS AT 18 (2D- IF STRENGTH AXIS IS THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). K. PANEL SUPPORTS AT 24'. CASING OR FINISH NAILS SPACED AT 6 INCHES ON PANEL EDGES, 12INCHES AT INTERMEDIATE SUPPORTS. L. FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (2112' x 0.113") ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS. M. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16'. N. FOR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED AT 4 INCHES ON CENTER AT EDGES, 81NCHES AT INTERMEDIATE 21. 1' B" SHEATHING TO EACH BEARING 3-8d COMMON (21YT X 0.131") FACE NAIL 22 WIDER THAN 1'X8' SHEATHING TO EA.BEARING 3-8d COMMON (21/2"X 0.131-) FACE NAIL 23. BUILT-UP CORNER SUDS 16d COMMON (3 112' X 0.162-) MIN. 24" O.C. 3' X 0.131' NAILS 18 O.C. SUPPORTS. 3" 14 GAUGE STAPLES 16" O.C. O. FASTENERS SPACED AT 41NCHES ON CENTER AT EDGES, B INCHES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND SHEATHING 31NCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. P. FASTENERS SPACED AT 41NCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. Q. SEE FASTENER ALTERNATE SCHEDULE. R. FASTENERS MUST BE INSTALLED WITH EVEN SPACING BETWEEN THEM ACROSS ATTACHING MEMBER. ALTERNATE FASTENING SCHEDULE CONNECTION I FASTENING ALT 3133. WOOD STRUCTURAL PANELS AND PARTICLEBOARD SUBFLOOR ROOF AND WALL SHEATHING (TO FRAMING) I 112E AND LESS I 2' X 0.092E RING SHANK NAIL S FROM EDGE, 10" O.C. ~� TOP LINE ENGINEERING, LLC STRUCTURAL ENGINEERS William E. Neary, III SMP-51, SMI-79, ICC 5185040 10649 Oakview Pointe Terrace Gotha, Florida 34734 3'- MODULAR PLANS DESIGN, CO. CONSULTING ENGINEER JULIO ORBEGOSO FLORIDA BUNGALOW SHED - HVHZ PE LICENSE #38769 MODULAR PLANS DESIGN, CO. 202 DOHS DRIVE., SURE 105 OFFICE: 863.688.105E LAKELAND, FLORIDA FAX:863.688.7118 COLEQMODUL 33813 ARPLANSCO.COM 1UZI-U2-Ub IUF LINL LNUINLLKINV /-\rrKUVHL rLAN 4 BUNU-HVHL-1U "' HVHL AF'F'KUVLU