HomeMy WebLinkAboutHVAC Load Calculationsoad Calculations
for
Residence
0003Carlton Rd
Port Saint Lucie, F| 34987
HVAC L-O"s
Digitally signed
Miranda P.E.
3SS79
2021.07.22
RhvauisanACCAapproved Manual J.Dand Scomputer program.
F IN E x�y00�y��
Prepared By:
ReymundoJ. Miranda PE
Uo#35578
S2U8VV72ndAve
Miami F|33144
30547Q5249
Thursday, July 22.2O21
Rhvac Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
JNL i3f u Corp ® A y
, 3144 ` �Page 2iM
Project Report
General -Pro ect nforrnation
Project Title:
Designed By: Nereyda Quintana
Project Date: Monday, April 19, 2021
Client Name: Residence
Client Address: 6003 Carlton Rd
Client City: Port Saint Lucie, FI 34987
Company Name: Lic #35579
Company Representative: Reymundo J. Miranda PE
Company Address: 920 SW 72nd Ave
Company City: Miami FI 33144
Company Phone: 305-479 5249
Company E-Mail Address: jnlgroup@aol.com
Company Comment:
Desl n Data w x...e s
Reference City: L Miami, Florida
Building Orientation: Front door faces North
Daily Temperature Range: Low
Latitude: 25 Degrees
Elevation: 7 ft.
Altitude Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 47 44.1 n/a n/a 72 n/a
Summer: 90 77 56% 50% 75 55
Total Building Supply CFM: 2,010 CFM Per Square ft.: 0.895
Square ft. of Room Area: 2,245 Square ft. Per Ton: 495
Volume (ft'): 22,450
Total Heating Required Including Ventilation Air: 39,417 Btuh 39.417 MBH
Total Sensible Gain: 48,859 Btuh 90 %
Total Latent Gain: 5,565 Btuh 10 %
Total Cooling Required Including Ventilation Air: 54,424 Btuh 4.54 Tons (Based On Sensible + Latent)
Notes:
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your
design conditions.
N:\ ...\6003 Carlton Rd Port Saint Lucie.rh9 Thursday, July 22, 2021, 2:23 PM
Rfivac Residential4& Light Commercial HVAC Loatls
Elite Software Development'Inc.
JNL Groorp
upC
Miami, F-,L o33144 a
Pa e'3°
Total Building Summary Loads
„,Component P Area q Sens Lat
. Sem ta[
1 .. k•.a J f k .•g
aDescri tion `t , ..e�,. �. a . , "'> ,. "- I . v,E „ � .,,_ ,, - , Ouan Loss, Gam
. Gam, Gain,
r , �.
SHGC46UV1: Glazing -Operable Window Impact 493.7 12,344 0
30,958 30,958
Resistant, single tinte, no break, ground reflectance
= 0.32, U-value 1, SHGC 0.46
13A-5ocs: Wall -Block, board insulation only, R-5 board 1407.3 4,399 0
3,395 3,395
insulation, open core, siding finish, U-value 0.125
13A-5ocs: Part -Block, board insulation only, R-5 board 460 920 0
978 978
insulation, open core, siding finish, U-value 0.125
16BR-30: Roof/Ceiling-Under Attic with Insulation on Attic 2245 1,796 0
3,879 3,879
Floor (also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material, Any Roof Color, R-30 insulation, U-
value 0.032
22A-ph: Floor -Slab on grade, No edge insulation, no 236 8,012 0
0 0
insulation below floor, any floor cover, passive,
heavy moist soil, U-value 1.358
Subtotals for structure: 27,471 0
39,210 39,210
People: 4 920
1,200 2,120
Equipment: 0
2,500 2,500
Lighting: 0
0 0
Ductwork: 6,709. 1,035
4,343 5,378
Infiltration: Winter CFM: 191, Summer CFM: 97 5,237 3,610
1,606 5,216
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0
0 0
Total Building Load Totals: 39,417 5,565
48,859 54,424
a
r
Check,FI gg ures
Total Building Supply CFM: 2,010 CFM Per Square ft.:
0.895
Square ft. of Room Area: 2,245 Square ft. Per Ton:
495
Volume (ft3): 22,450
°Buildin " Loads
Total Heating Required Including Ventilation Air: 39,417 Btuh 39.417 MBH
Total Sensible Gain: 48,859 Btuh 90 %
Total Latent Gain: 5,565 Btuh 10 %
Total Cooling Required Including Ventilation Air: 54,424 Btuh 4.54 Tons (Based
On Sensible + Latent)
u
t,
[Notes ,
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your
design conditions.
N:\ ...\6003 Carlton Rd Port Saint Lucie.rh9 Thursday, July 22, 2021, 2:23 PM
Rhvac Residential%& Light Commercial HVAC Loads Ehte Software Development' Inc:
�NL Group:Corp „
'Miarni,+L 33144 ;Page 4, •
System 1 A/C-1 Summaty Loads
Cmponent ; k " Area Sens Ala-'.1-1, x
o' aSen = a Total',
Desch'"tion g Quan Loss;=. Garn Gain Garii
SHGC46UV1: Glazing -Operable Window Impact 264.6 6,615 0 18,338 18,338
Resistant, single tinte, no break, ground reflectance
= 0.32, U-value 1, SHGC 0.46
13A-5ocs: Wall -Block, board insulation only, R-5 board 698.4 2,183 0 1,685 1,685
insulation, open core, siding finish, U-value 0.125
13A-5ocs: Part -Block, board insulation only, R-5 board 460 920 0 978 978
insulation, open core, siding finish, U-value 0.125
16BR-30: Roof/Ceiling-Under Attic with Insulation on Attic 1249 999 0 2,158 2,158
Floor (also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material, Any Roof Color, R-30 insulation, U-
value 0.032
22A-ph: Floor -Slab on grade, No edge insulation, no 142 4,821 0 0 0
insulation below floor, any floor cover, passive,
heavy moist soil, U-value 1.358
Subtotals for structure: 15,538 0 23,159 23,159
People: 0 0 0 0
Equipment: 0 2,500 2,500
Lighting: 0 0 0
Ductwork: 3,554 508 2,315 2,823
Infiltration: Winter CFM: 137, Summer CFM: 71 3,777 2,625 1,168 3,793
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
System 1 A/C-1 Load Totals: 22,869 3,133 29,142 32,275
GheckFi ures',k�r,x a ',.rW
4.
Supply CFM: 1,225 CFM Per Square ft.: 0.981
Square ft. of Room Area: 1,249 Square ft. Per Ton: 464
Volume (ft'): 12,490
S. stem Loads„ r t A
Total Heating Required Including Ventilation Air: 22,869 Btuh 22.869 MBH
Total Sensible Gain: 29,142 Btuh 90 %
Total Latent Gain: 3,133 Btuh 10 %
Total Cooling Required Including Ventilation Air: 32,275 Btuh 2.69 Tons (Based On Sensible + Latent)
Notes°, r� w :,. x �«,..•_. `r; y4
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your
design conditions.
N;\ ...\6003 Carlton Rd Port Saint Lucie.rh9 Thursday, July 22, 2021, 2:23 PM
vResdential'8 Ught CommercialHVAC Loads
< Elite Software DeveloI'jRh3cNL
Group,Corp
_MIamI,.EL $3t4
_
age5
System 2 A/C-2 Summary Loads
Compone,'nt Sena„ Lat Sen."Total'
Descri ti.on ' Quan.,.a Loss> Gam :, Gain
Gain:
SHGC46UV1: Glazing -Operable Window Impact 229.1 5,729 0 12,620
12,620
Resistant, single tinte, no break, ground reflectance
= 0.32, U-value 1, SHGC 0.46
13A-5ocs: Wall -Block, board insulation only, R-5 board 708.9 2,216 0 1,710
1,710
insulation, open core, siding finish, U-value 0.125
16BR-30: Roof/Ceiling-Under Attic with Insulation on Attic 996 797 0 1,721
1,721
Floor (also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material, Any Roof Color, R-30 insulation, U-
value 0.032
22A-ph: Floor -Slab on grade, No edge insulation, no 94 3,191 0 0
0
insulation below floor, any floor cover, passive,
--..._heavy moist soil, U_value 1.358._......---------....------ ...... ..... ..... ........... _..................................
Subtotals for structure: 11,933 0 16,051
16,051
People: 4 920 1,200
2,120
Equipment: 0 0
0
Lighting: 0 0
0
Ductwork: 3,155 527 2,028
2,555
Infiltration: Winter CFM: 53, Summer CFM: 27 1,460 985 438
1,423
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0
0
System 2 A/C-2 Load Totals: 16,548 2,432 19,717
22,149
r
Supply CFM: 785 CFM Per Square ft.:
0.788
Square ft. of Room Area: 996 Square ft. Per Ton:
540
Volume (ft'): 9,960
_
Total Heating Required Including Ventilation Air: 16,548 Btuh 16.548 MBH
Total Sensible Gain: 19,717 Btuh 89 %
Total Latent Gain: 2,432 Btuh 11 %
Total Cooling Required Including Ventilation Air: 22,149 Btuh 1.85 Tons (Based On Sensible +
Latent)
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your
design conditions. .
N:\ ...\6003 Carlton Rd Port Saint Lucie.rh9 Thursday, July 22, 2021, 2:23 PM