FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 27 Phase 3 Waterstone 2508 CRGL
Builder Name: ADAMS HOMES
Street: 8315 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV020.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 272.00 ft2
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2623.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ft2
6. Conditioned floor area above grade (ft2) 2523
b. Knee Wall (Vented)
R=19.0 100.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(293.4 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
0
SHGC: SHang
Area Weighted Average Overhang Depth: 6.223 ft.
.
14Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2523.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 71.33
Glass/Floor Area: 0.116
PASS
Total Baseline Loads: 71.64
I hereby certify that the plans ications covere
' Revi of the plans and
this calculation are in comp a Flo r' ergy
specifications covered by this
- p
Code.
calculation indicates compliance
with the Florida Energy Code.
ti rinr`;s"�•' `.•� ;, Gp.
PREPARED BY: ,.
Before construction is completed
C
DATE: 06-08-9n91 Winn KPnmany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida -Energy E�
OWNE�;�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403:3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
w_ envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). .
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2ngn 1K101 1T 01 MARR A ev ...�
• vv......r1�� vnG�rf�LIJ 1 mr-rum 1
PROJECT
Title:
Lot 27 Phase 3 Waterstone
2 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2523
Lot #
27-3
Owner Name:
# of Units:
1
Total Stories: 1
Block/Subdivision:
Waterstone
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8315 Amalfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
New/Existing:
New (From Plans)
FL, 34951
Comment:
CLIMATE
Design
Location
Design Temp
TMY Site
Int Design Temp Heating
Design Daily Temp
97.5 % 2.5 %
Winter Summer Degree Days
Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ftz ----
0.44 0 0.56
ROOF
V #
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ft2 630 ftZ Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2523 ft' 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
100 ftZ 0.11
Wood
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
M�
M
WALLS
;a
Ornt
Adjacent
Space
Cavity Width
Et In
Height
In
Sheathing Framing
Solar
Below
1
2
3
4
5
6
7
8
9
E
N
W
SW
S
-
S
E
W
Exterior
Exterior
Exterior
Exterior
Exterior
Garage
Exterior
Exterior
Exterior
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Frame - Wood
Concrete Block - Int Insul
Concrete Block - Int Insul
Concrete Block - Int Insul
Main
Main
Main
Main
Main
Main
Main
Main
Main
4.1 48
4.1 37
4.1 51
4.1 6
4.1 37
13 34
4.1 23
4.1 8
4.1 6
Et
6 8
2 8
3 8
2 8
6 8
0 8
6 8
6 8
0 8
0
0
0
0
0
0
0
0
0
- Arpn
388.0 ft2
297.3 ft2
410.0 ft2
49.3 ft2
300.0 ft2
272.0 ft2
188.0 ft2
68.0 ft2
48.0 ft2
RX
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.23
0
0
0
0.6
0.6
0.6
0.6
0.6
0.01
0.6
0.6
0.6
0
0
0
0
0
0
0
0
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value Width
Height
Area
Ft In
Ft In
1
N
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2 8
6 8
17.8 ft2
3
W
Insulated
Main
None
.25
2 4
6 8
15.6 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/
Wall
Overhang
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth Separation
Int Shade
Screening
1
E
1
Vinyl
Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in 0 ft 10 in
Drapes/blinds
None
2
E
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in 0 ft 10 in
Drapes/blinds
Exterior 5
3
N
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
7.5 ft2
13 ft 0 in 0 ft 6 in
None
None
4
N
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
13.3 ft2
13 ft 0 in 2 ft 10 in
None
None
5
N
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
32.4 ft2
7 ft 4 in 1 ft 4 in
Drapes/blinds
Exterior 5
6
N
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in 2 ft 0 in
Drapes/blinds
Exterior 5
7
W
3
Vinyl
.Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in 0 ft 10 in
Drapes/blinds
Exterior 5
8
W
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in 0 ft 10 in
Drapes/blinds
Exterior 5
9
SW
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in 0 ft 4 in
Drapes/blinds
Exterior 5
10
S
5
Vinyl
Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in 0 ft 10 in
Drapes/blinds
None
11
S
5
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft 2 in 0 ft 4 in
Drapes/blinds
Exterior 5
12
S
7
Vinyl
Low-E Double
Yes
0.33 0.23
N
30.0 ft2
9 ft 10 in 0 ft 4 in
Drapes/blinds
Exterior 5
13
S
5
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in 1 ft2 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height E;;;i
all Insulation
1
620
ft2
620 ft2
64 ft
g ft
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
1 Wholehouse Proposed ACH(50)
SLA
.000391
CFM 50 ELA EgLA ACH ACH 50
2590.3 142.11 266.8 .1312 7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing] HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cent # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/
V
Supply ----
# Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling j Jan Feb Mar
Heating X1 Jan XFeb Mar
Venting [ ] Jan Feb XMar
Ceiling Fans:
Se
APr MaJunJul uSep
Apr ]Mayrj Jun rl
Jul Nug
u rl
[X] A r [ Ma Jun JulSe [X]
Oct Nov
Oct Nov
Oct HX Nov
Dec
Dec
H Dec
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8315 Amalfi Circle,
Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ftz
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
272.00 ftz
^
c. N/A
R=
ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (ftz)
2523
a. Under Attic (Vented)
b. Knee
R=30.0
2523.00 ftz
Wall (Vented)
R=19.0
100.00 ftz
7. Windows- Description
Area
c. N/A
R=
ftz
a. U-Factor: Dbl, U=0.33
166.06 ftz
12. Ducts, location & insulation level
R ftz
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33
70.92 ftz
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
35.56 ftz
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details) 20.83 ftz
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
- Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftz
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0 2523.00 ftz
None
b. N/A
R= ftz
Credits (Performance method)
Pstat
c. N/A
R= ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature '�_ Date:
Address of New Home:
City/FL Zip:
^ `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/8/2021 5:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1