HomeMy WebLinkAboutEnergy Coder
T
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Lot 176 Phase 3 Waterstone 1820 BGL
Street:
5327 Vespera Street
City, State, Zip:
Fort Pierce, FL, 34951
Owner:
Design Location:
FL, ST_LUCIE_CO_INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type�2120.0 sgft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - I'm Insul, Exterior
R=4.1 1850.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 270.00 ft2
4. Number of Bedrooms
4
c. N/A
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (1900.0 sqft.)
R= ftZ
Insulation Area
6. Conditioned floor area above grade (ft2)
1820
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 1820.00 ft2
R=19.0
Conditioned floor area below grade (ft2)
0
c. N/A
80.00 ft2
R=
7. Windows(239.3 sgft.) Description
Area
12. Ducts
ft2
R ft2
a. U-Factor: Dbl, U=0.33
168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC:
32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC=0.21
c. U-Factor: Dbl, U=0.33
20.42 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth:
4.067 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
SHGC(AVG): N/A
15. Hot water systems
9. Floor,Types (1820.0 sgft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1820.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.131
Total Proposed Modified Loads: 60.11
PASS
Total Baseline Loads:
64.83
I hereby certify that the plans
this calculation are in comp
Code.
PREPARED
DATE:n.--68-2nqi xmnmiKearnany
I hereby certify that this building, as designed, is in compliance
with the Florida Ener Code.
OWNER/AGEN
DATE:
ReviR�lv of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- %,unilmdime requires cernticatton by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.211.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2).
6/8/2021 9:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 176 Phase 3 Waterstone Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1820
Lot #
176-3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5327 Vespera Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2 ----
0.42 0 0.58
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ft2 0.11
Wood
6/8/2021 9:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 IAIDI IT Q1IRAIMAON/ f%L1=o-1l1 1c,Tr r%. m-
...�.�. v.�VVf\L.1�71 RGI�V1�1.
WALLS
Adjacent pe-Space
Cavity Width
Height
Sheathing Framing
Solar Below
1 N
Exterior Concrete Block - Int Insul
Main
4.1 59 0
10 0
590.0 ft2
0
0
0.6
0
2 W
Exterior Concrete Block - Int Insul
Main
4.1 20 0
10 0
200.0 ft2
0
0
0.6
3 S
Exterior Concrete Block - Int Insul
Main
4.1 66 0
10 0
660.0 ft2
0
0
0.6
0
4 E
Exterior Concrete Block - Int Insul
Main
4.1 40 0
10 0
400.0 ft2
0
0.6
0
0
5 -
Garage Frame - Wood
Main
13 27 0
10 0
270.0 ft2
0
0.23
0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
W Insulated
Main
None
.25
3
6 8
20 ft2
2
- Insulated
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1 Vinyl Low-E Double
Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
N
1 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
W
2 Vinyl Low-E Double
Yes
0.33 0.31 N
7.1 ft2
9 ft 0 in
0 ft 6 in
None
None
4
W
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
3 ft 11 in
None
Exterior 5
5
W
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
5 ft 4 in
None
Exterior 5
6
W
2 Vinyl Low-E Double
Yes
0.33 0.31 N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
S
3 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
Oft 10 in
None
Exterior 5
8
E
4 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
11 ft 5 in
0 ft 6 in
None
Exterior 5
9
E
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
E
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
11 ft 6 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49 218.7
.1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Sing] HSPF:8.5
34.6 kBtu/hr
1
sys#1
6/8/2021 9:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 IAIDI IT 01IRRRAAnv ^1 ffr ..,� .....__
-�••...�.-.�. vnGLrf�LIJ I 1«rUK I
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing] SEER: 16 35 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Com an Name
p y
Collector
System Mode] # Collector Model # Area
Storage
Volume
FEF
None
None
ft2
DUCTS
/
---- Supply ----
Location R-Value Area
---- Return --- Air
Location Area Leakage Type Handler
CFM 25 CFM25
HVAC #
TOT OUT
QN
RLF
Heat Cool
1
Attic
6 364 ft2 Main
91 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling
Fans:
Cooling Jan
Heating IXI Jan
Venting [ ]Jan
Feb
f X Feb
[ Feb
] Mar
�X] Mar
X] Mar
A r
A r
Apr
Ma Jun Jul Aug
Ma rj Jun X Jul X Augrl
May Jun r i � �
Se
Sep
Oct
Oct
Nov
Nov
Dec
Dec
�
Jul Aug
Sep [X]
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78 78
80 78
78 78 78 78
78
78 80
80
80
80
Cooling (WEH)
AM
78
78 78
78 78 78
78 78 78
78 78
78
78
78
PM
78
78 78
78
78 78 78 78
78 78
78 78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66 66
68 68
66 66 68 68
68
68 68
68
68
68
Heating (WEH)
AM
66
66 66
68 68 68
66 66 68
68 68
68
66
66
PM
68
68 68
68
68 68 68 68
68 68
68 68
68
68
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 lbs/s
.ft.
0 ft2
0 ft 0.3
Main
6/8/2021 9:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.31
d. U-Factor: other (see details
SHGC: other (see details
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5327 Vespera Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ft2
1
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
c. N/A
R=
ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
Area
c. N/A
R=
ft2
168.74 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
32.38 ft2
13. Cooling systems
kBtu/hr
Efficiency
20.42 ft2
a. Central Unit
35.0 SEER:16.00
17.78 ft2
14. Heating systems
kBtu/hr
Efficiency
4.067 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
0.269
Area
15. Hot water systems
ft2
a. Electric
Cap:
40 gallons
EF: 0.94
b. Conservation features
Insulation
Area
None
R=0.0
1820.00 ft2
Credits (Performance method)
R=
ft2
Pstat
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signatur�.\_ Date:
Address of New Home: City/FL Zip:
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
F Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/8/2021 9:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1