Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 18 Phase 3 Waterstone 2265 CRGL Builder Name: ADAMS HOMES Street: 8328 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type42018.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ftZ 4. Number of Bedrooms 4 c. Frame - Wood, Adjacent � d. N/A R=13.0 232.00 ftz R= ftZ 5. Is this a worst case? No 11. Ceiling Types (2377.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ftZ) 2277 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2277.00 ftZ R=19.0 100.00 ftz Conditioned floor area below grade (ftZ) 0 c. N/A R= ftz 7. Windows(293.9 sqft.) Description Area 12. Ducts R ftZ a. U-Factor: Dbl, U=0.33 166.06 ftz a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 35.56 ftz SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.160 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (2277.0 sqft.) Insulation Area a. Electric Ca 40 p: gallons a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftZ b. Conservation features EF: 0.940 b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Glass/Floor Area: 0.129 Total Proposed Modified Loads: 67.23 PASS Total Baseline Loads: 67.80 I hereby certify that the plan cifications covere ' ew of the plans and this calculation are in cc i ith the Flo nergy specifications covered by this p. Code. calculation indicates compliance PREPARED BY: with the Florida Energy Code. Before is trnr''�% Fsc.`, w� ��'O construction completed DATE: -_ n6-r)9-2m1 niinn Kann,any this building will be inspected for _ - a. compliance with Section 553.908. - I hereby certify that this building, as designed, is in compliance with the Florida'' Florida Statutes. OWNER/Al �-- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the.air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). R 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 ,FORMR4n5-gngn IAIDI IT QIIIIAIIAAOV l+LIO^wI Ic—v nr-rt,. — v■ IVVI'kVIV I I\Lr VIt 1 PROJECT Title: Lot 18 Phase 3 Waterstone 2 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2277 Lot # 18-3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8328 Amalfi Circle Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , New/Existing: New (From Plans) FL, 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ftz _--- 0.35 0 0.65 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2546 ftz 570 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC ` / `� # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2277 ftZ 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 100 ft' 0.11 Wood 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 M I-UKIh+K4U5-2020 INPUT SUMMARY CHECKLIST REPORT F1 WALLS Adjacent Sp ace Cavity Width Height Sheathing Framing Solar Below 2 3 4 5 6 7 8 9 10 _11 E E N N W W SW SW S S - Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Garage •Frame Frame - Wood Concrete Block - Int Insul Frame - Wood Concrete Block - Int Insul Frame - Wood Concrete Block - Int Insul Frame - Wood Concrete Block - Int Insul Frame - Wood Concrete Block - Int Insul - Wood Main Main Main Main Main Main Main Main Main Main Main 13 10 4.1 38 13 4 4.1 28 13 6 4.1 50 13 3 4.1 0 13 18 4.1 37 13 29 2 7 6 6 9 3 10 5 11 8 0 8 10 10 10 8 8 10 10 10 8 8 0 0 0 0 0 0 0 0 0 0 0 81.3 ft2 385.8 ft2 45.0 ft2 285.0 ft2 54.0 ft2 402.0 ft2 38.3 ft2 4.2 ft2 189.2 ft2 301.3 ft2 232.0 ft2 0 0 0 0 0 0 0 0 0 0 0 0.23 0 0.23 0 0.23 0 0.23 0 0.23 0 0.23 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.01 0 0 0 0 0 0 0 0 0 0 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In Wood Main None .25 2 8 6 8 17.8 ft2 L3EE W Insulated Main None .25 2 4 6 8 15.6 ftZ N Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered Prnnncorl / # Ornt Wall ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 E 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 N 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 12 ft 8 in 0 ft 6 in None None 4 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 12 ft 8 in 2 ft 10 in None None 5 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft' 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 W 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 8 W 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in . Drapes/blinds Exterior 5 9 SW 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 S 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 S 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft' 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 S 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 In Drapes/blinds Exterior 5 13 S 9 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 14 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 1 ft 0 in 1 ft 10 in Drapes/blinds None 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORNrR405-2020 IAIDI IT cl MARRAov t+u�nvi ic+7- ■,.-r.... ....■.r-..� vl �VVf\L1�71 RGi VI[ 1 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617ft' 617ft2 64ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH (50) .0004 2390.9 131.17 246.26 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS / # ---- Supply ---- Location R-Value Area # ---- Return --- Air CFM 25 CFM25 EHeat Location Area Leakage Type Handler TOT OUT QN RLoolAttic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM•R405-2020 IAIDI IT Q1IIIA11AAov r•urnvm i^qr ••....�.� � v� �Vvr�L1�7 1 1ZGrV1[ 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating H Jan Venting Jan Feb H Feb Feb Mar Mar HX Mar A r APr [X] Apr [[[ [ May [ MayJun May X Jun [ Jun Jul Jul rl Jul u Mug Aug Se Sep ri Se Oct Oct [X] Oct Nov Nov Nov HX [ ] Dec [[Xl] Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 8328 Amalfi Circle, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Exterior 1 c. Frame - Wood, Adjacent 4 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 2277 b. Knee Wall (Vented) Area c. N/A 166.06 ft2 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 70.92 ft2 13. Cooling systems 35.56 ft2 a. Central Unit 21.33 ft2 5.160 ft. 0.288 Area ft2 Insulation Area R=0.0 2277.00 ft2 R= ft2 R= ft2 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on inst ed Code compliant features. Builder Signa re Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1378.30 ft2 R=13.0 407.83 ft2 R=13.0 232.00 ft2 R= ft2 Insulation Area R=30.0 2277.00 ft2 R=19.0 100.00 ft2 R= ft2 R ft2 6 456.2 kBtu/hr Efficiency 35.0 SEER:16.00 kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/9/2021 10:21 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1