Loading...
HomeMy WebLinkAbout4637 S Header Canal Rd FASTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-2153829 DOCUMENT #:FI1698965 AP1566127APPLICATION #: 56-PID-4767806 10/29/2020 LOT: ID#: BLOCK: SUBDIVISION: APPLICANT:Juan Quinteros AGENT:Jessica Quinteros PROPERTY ADDRESS:4637 S Header Canal Rd Fort Pierce, FL 34945 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. [01] TANK SIZE[][1]1090.00 [2] [02] TANK MATERIAL[]Polypropylene [03] OUTLET DEVICE[] [04] MULTI-CHAMBERED[][Y ]N/ [05] OUTLET FILTER[] [06] LEGEND[] [07] WATERTIGHT[] [08] LEVEL[] [09] DEPTH TO LID[] TANK INSTALLATION [27] SURFACE WATER[]100 SETBACKS FT [28] DITCHES[]100 FT [29] PRIVATE WELLS[]100 FT [30] PUBLIC WELLS[]FT [31] IRRIGATION WELLS[]FT [32] POTABLE WATER []88 FT [33] BUILDING FOUNDATIONS[]5.5 FT [34] PROPERTY LINES[]100 FT [35] OTHER[]FT [10] AREA[][1]672 [2] [11] DISTRIBUTION[] [12] NUMBER OF DRAINLINES[] [13] DRAINLINE SEPARATION[] [15] DEPTH OF COVER[] [16] ELEVATION [] [17] SYSTEM LOCATION[] [18] DOSING PUMPS[] [19] AGGREGATE SIZE[] DRAINFIELD INSTALLATION SQFT BOX HEADER X [BELOW ]BMABOVE/31.00 [14] DRAINLINE SLOPE[] [20] AGGREGATE EXCESSIVE FINES[] [21] AGGREGATE DEPTH[] [36] DRAINFIELD COVER[] FILLED / MOUND SYSTEM [37] SHOULDERS[] [38] SLOPES[] [39] STABILIZATION[]09/16/2021 [40] UNOBSTRUCTED AREA[] ADDITIONAL INFORMATION [41] STORMWATER RUNOFF[] [42] ALARMS[] [43] MAINTENANCE AGREEMENT[] [44] BUILDING AREA[] [45] LOCATION CONFORMS WITH SITE PLAN[] [46] FINAL SITE GRADING[] [47] CONTRACTOR[]Roselis Moctezuma (All Coas [48] OTHER[]INFILTRATOR Quick4 EQ36 (single c [49] TANK PUMPED[] ABANDONMENT [50] TANK CRUSHED & FILLED[] [22] FILL AMOUNT[] FILL / EXCAVATION MATERIAL [23] FILL TEXTURE[] [24] EXCAVATION DEPTH[] [25] AREA REPLACED[] [26] REPLACEMENT MATERIAL[] Polylok PL-68 1.2. 1.2.7.00 70-143-11DC4 7 3202-5000-0007-000-3 Comments are on page 2.Comments: CONSTRUCTION []:/CHD DATE: DISAPPROVED St. Lucie 04/30/2021APPROVED Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM []:/CHD DATE:DISAPPROVED St. Lucie 09/16/2021 Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH) APPROVED (Explanation of Violations on following page) EH Database v 1.0.1 AP1566127 EID2153829 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL PERMIT #: DATE PAID: FEE PAID: RECEIPT #: 25.00 56-SF-2153829 DOCUMENT #:FI1698965 AP1566127APPLICATION #: 56-PID-4767806 10/29/2020 Violation Number Comment The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 7x8 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Needs final inspection for well inspection/setback/location, mound system and final site grading. Final system approved. Contractor and Building Department emailed final approval. Comments EH Database v 1.0.1 AP1566127 EID2153829 Page 2 of 3 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC