Loading...
HomeMy WebLinkAbout217436-1d compaction signedHeadquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: September 16, 2021 KSM JOB #: 217436-1d/BS/ah NUC # 528 PERMIT #: 2107-0879 Nuc Model: MC-IDR-P Nuc Serial #: MD049528 CONTRACTOR: Adams Homes JOB LOCATION: 8311 Amalfi Circle Lot 26, Waterstone Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 N.E. 0" - 12" 45 107.2 108.8 98.5% 2 S.E. 1 106.9 " 98.3% 3 Center 1 107.7 " 99.0% 4 S.W. 1 108.0 " 99.3% 5 N.W. 1 107.5 " 98.8% Soil Description: 110.0 I I I I I I I I Brown Sand W I I I I I I I E109.0 L..�..—..—..�..—..—..—..�..—..—.._ In Place Moisture: I I I I I I I I G ' 10.5% H 108.0 a—.. �..—.�—.. ..—I._..�—..—.�.—.._ Proctor Optimum Moisture: T 107.0 J.._.I_..l ._I._..L..J.._ _.._ 12.0 % p I I I I I I Proctor Max. Dry Density: P.C.F. 106.0 • • -4• • — • I 4--1 — • — -4 • • — • 1— - 108.8 C I I I I I I I @ Test Locations the Density & F 1050 =— — 1—"t"-1'—"1-- —I"—'I—"- Penetrometer readings indicate the I I I I I I I Degree of Compaction Meets I 104.0 �— —' - —I Minimum Requirement D I I T' I' �" f for Staked Foundation R I I I I I I I 103.0..�..—.i_..t.._i._..�..�..—.r—..� Respectfully SubNa-Aally VV it Y 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight signed by T„isltem has bee^elec[ro^Ically slg^edand Julie Keller Disclaimer: Contractor is responsible to maintain the tested area sealed by Tulle Keller, P.E. EI. Llc. H—on t„edateatMeldirectlyt°t„erig„t^,i^ga d;gitalaignaNre. Date: document in the condition that KSM completed the indicated passed noted copies of [b;s are not �onslderede;gnada^d.aaladandt„e compaction test. KSM is not responsible if the tested area has signature must be verified on any elect,.— 2021 .09.1 6 been altered from the approved inspected condition. 15:23:00 Julie E. Keller, P.EOPIAPent PE# 68366 9/16/2021 Email to: St. Lucie County Building Department; rick.johnson@adamshomes.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE