Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSled a ra I Phone: 954-784-2941 E-Fax: 954-784-7875 gineering admin(Wed-eng.com www.ied-eng.com esting, Inc. DATE: 9/14/21 Order No.: 21RO753 CLIENT: Go Solar Power ADDRESS: - 933 Clint Moore Road; Boca Raton, FL 33064 PROJECT: Oluwafemi Residence Sloped Wood Deck ADDRESS: 104 S.E. Bonita Court; Port St Lucie, FL 34983 ASCE 7-16 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30, Part I Proiect Information: Skylights for Sloped Wood Deck Height = 14' Exposure: C Ultimate Windspeed: V,tt=170 mph Length = 58' Category: II Basic Windspeed: V.,d = 132 mph Width = 41' Slope: 3:12 K, = 0.85 Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*[(0.85)(0.85)(1.00)(1.00)(132)'] = 32.2 psf Width of Pressure Coefficient Zone: 0.1(41') = 4.1' 0.4(14') = 5.6' } use: a= 4.1' External Pressure Coefficient: 1) GCPF = -2.0 2e) GCP1 = -2.0 2n) GCP3 = -3.0 2r) GCP3 = -3.0 3e) GCP3 = -3.0 3r) GCP3 = -3.6 GCP,,2,3 = +0.7 Design Pressures: Internal Pressure Coefficient: 1) GCPi = 0.18 GCPi = -0.18 Zone 1 P1 = 32.2*(-2.0 - 0.18) = -70.2 psf Zone 2e P2e = 32.2*(-2.0 - 0.18) = -70.2 psf Zone 2n P2n = 32.2*(-3.0 - 0.18) = -102.4 psf Zone 2r P2r = 32.2*(-3.0 - 0.18) = -102.4 psf Zone 3e P3e = 32.2*(-3.0 - 0.18) = -102.4 psf Zone 3r P3r = 32.2*(-3.6 - 0.18) = -121.7 psf 3370 NE 5th Avenue I Oakland Park Florida 33334 (aciItllll ll'IIF MIAM CMEC! COUNTY • • D GrT� Page 2 9/14/21 Oluwafemi Skylight 104 S.E. Bonita Court Port St Lucie, FL 34983 Zone 1 Zone 2e Zone 2n Zone 2r Zone 3e Zone 3r P1 = 32.2*(+0.7 + 0.18) = -28.3 psf P2e = 32.2*(+0.7 + 0.18) = -28.3 psf P2n = 32.2*(+0.7 + 0.18) = -28.3 psf P2r = 32.2*(+0.7 + 0.18) = -28.3 psf P3e = 32.2*(+0.7 + 0.18) = -28.3 psf P3r = 32.2*(+0.7 + 0.18) = -28.3 psf Maximum Design Pressure Ratings From NOA #20-0813.02 Positive = +60 psf Negative = -80 psf Attachment Requirements: Based on the information provided by the client, N.O.A. requirements, Florida Building Code 2020 edition and ASCE 7-16 Chapter 30 Wind Loads, the following skylights are approved for use for use in any roof Zone 1 or Zone 2e location at the above referenced residential single family home. All installations shall follow all of the provisions of the referenced product approval (NOA 20-0813.02) and requirements of the Florida Building Code, 2020 edition. Complies with Florida Building Code 2020 Edition, Section 1620.1. Based on N.O.A. #20-0813.02; the following are our recommended fastening patterns for the Birdview Aluminum Framed Polycarbonate Domed Skylights: #14 x 1" Pan Head Lag Screws spaced 3 7/8" from each corner with a maximum of 7'h" o/c screw spacing with minimum roof deck penetration of 7/8". Notes: All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and the Florida Building Code 2020 edition. Wind load calculations based on ASCE 7-16 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Sincerely, \\`�,•�` N J 0 HN �''%,�, !� 1cfHsF�l9 o, Keith LeBlanc, P.E. _ �� 5� 394 Federal Engineering & Tesmi' Florida Reg. No. 59394 v':gTF OF _ Certificate of Authorizati3 5* l Y p ••''tvw�,�` Miami -Dade County Certifici�� i�i 1141, 3370 NE 5th Avenue I Oakland Park Florida 33334 a is : M®m=4DEJ Food ._� Approved Laboratory //''�