HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
.. Florida Department of Business and Professional
Regulation - Residential Performance Method
Project Name: Lot 22 Phase 3 Waterstone 3000 CRGR
Builder Name: ADAMS HOMES
Street: 8312 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�2135.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1835.30 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 300.00 ftZ
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case?No
11. Ceiling Types (3110.0 sqft.)
Insulation Area
6. Conditioned floor area above grade (ftZ) 3000
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 3000.00 ftZ
R=19.0 110.00 ftz
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(292.5 sqft.) Description Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33 142.60 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 600
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 97.13 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
47.5 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ftZ
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 5.225 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.285
a. Electric Heat Pump
45.5 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (3000.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ftZ
b. Conservation features
EF: 0.940
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 77.60
PASS
Total Baseline
Loads: 77:90
I hereby certify that the plan d ifications covere
a 'ew of the plans and
TH� S7,gl
this calculation are in com is ith the Flo' nergy
specifications covered by this
p
Code.
calculation indicates compliance
with the Florida EnergyCode.
PREPARED BY: _ .�
Before construction is completed
DATE: 1718-na-91191 Winn Kammnny
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Efjerg!y,OD�
Florida Statutes.
OWNER/F
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.045 Qn for whole house.
6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 22 Phase 3 Waterstone 3 Bedrooms: 4
Address Type:
Lot Information
' Building Type:
User
Conditioned Area: 3000
Lot #
22-3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8312 Amalfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Detached
,
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
3000 25500
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
3000 25500 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main - 223.5 ft 0
3000 ft2 ----
0.46 0 0.54
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 3354 ft2 750 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
` /
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 3000 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
3000 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
110 ft2 0.11
Wood
6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
-
Height
Sheathing Framing Solar Below
o
1 E
Exterior
Concrete Block - Int Insul
Main
4.1 64
8
8 0
517.3 ft2
0
0 0.6
0
2 S
Exterior
Concrete Block - Int Insul
Main
4.1 65
0
8 0
520.0 ft2
0
0 0.6
0
3 W
Exterior
Concrete Block - Int'Insul
Main
4.1 49
0
8 0
392.0 ft2
0
0 0.6
0
4 N
Exterior
Concrete Block - Int Insul
Main
4.1 50
9
8 0
406.0 ft2
0
0 0.6
0
5 -
Garage
Frame - Wood
Main
13 30
0
10 0
300.0 ft'
0
0.23 0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated
Main
None
.25
5
4
6 8
35.6 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
2
S
2
Vinyl
Low-E Double
Yes
0.55 0.7
N
35.6 ft2
12 ft 4 in
1 ft 0 in
None
None
3
S
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft2
12 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
S
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
W
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
19.5 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
6
N
4
Vinyl
Low-E Double
Yes
0.33 0.21
N
64.8 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
7
N
4
Vinyl
Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 4 in
2 ft 6 in
Drapes/blinds
Exterior 5
8
N
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.3 ft2
1 ft 4 in
0 ft 6 in
None
None
9
N
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.3 ft2
4 ft 3 in
1 ft 0 in
None
None
10
N
4
Vinyl
Low-E Double
Yes
0.33 0.31
N
6.7 ft2
4 ft 3 in
3 ft 6 in
None
None
11
S
2
Vinyl
Low-E Double
Yes
0.33 0.23
N
32.4 ft2
12 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
448 ft2
448 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000378
2975 163.22
306.42
.1294
7
6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORRA R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split Sing] HSPF:8.5 45.5 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split S]ngl SEER: 15 47.5 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt
Conservation
1
Electric None
Garage 0.94 40 gal 70 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft'
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic
6 600 ftz
Main
150 ft'
Proposed Qn
Main
--- cfm
135.0 cfm 0.04 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Venting
an
f X Jan
Feb
Feb
H
HX
Mar
Mar
Apr
Apr
May
May
Jun
Jun
rl
Jul
Jul
rl
u
Mug Aug
Se
Sep
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
[ Jan
Feb
Mar
[X]
Apr
[
May
Jun
Jul
Se
[
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68,
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ftZ
0 ft
0.3
Main
.r
6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8312 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1835.30 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
300.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (ft2)
3000
a. Under Attic (Vented)
b. Knee
R=30.0
3000.00 ft2
Wall (Vented)
R=19.0
110.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
142.60 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 600
b. U-Factor: Dbl, U=0.33
97.13 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
C. U-Factor: Dbl, U=0.55
35.56 ft2
a. Central Unit
47.5 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
17.25 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
5.225 ft.
a. Electric Heat Pump
45.5
HSPF:8.50
Area Weighted Average SHGC:
0.285
S. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation
Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0
3000.00 ft2
None
b. N/A
R=
ft2
Credits (Performance method)
Pstat
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Sig Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1