Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION .. Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 22 Phase 3 Waterstone 3000 CRGR Builder Name: ADAMS HOMES Street: 8312 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�2135.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1835.30 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 300.00 ftZ c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case?No 11. Ceiling Types (3110.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ftZ) 3000 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 3000.00 ftZ R=19.0 110.00 ftz Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(292.5 sqft.) Description Area 12. Ducts R ftZ a. U-Factor: Dbl, U=0.33 142.60 ftZ a. Sup: Attic, Ret: Main, AH: Main 6 600 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 97.13 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 47.5 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ftZ SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.225 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 45.5 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (3000.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ftZ b. Conservation features EF: 0.940 b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 77.60 PASS Total Baseline Loads: 77:90 I hereby certify that the plan d ifications covere a 'ew of the plans and TH� S7,gl this calculation are in com is ith the Flo' nergy specifications covered by this p Code. calculation indicates compliance with the Florida EnergyCode. PREPARED BY: _ .� Before construction is completed DATE: 1718-na-91191 Winn Kammnny this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Efjerg!y,OD� Florida Statutes. OWNER/F BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. . - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.045 Qn for whole house. 6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 22 Phase 3 Waterstone 3 Bedrooms: 4 Address Type: Lot Information ' Building Type: User Conditioned Area: 3000 Lot # 22-3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8312 Amalfi Circle Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 3000 25500 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3000 25500 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main - 223.5 ft 0 3000 ft2 ---- 0.46 0 0.54 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 3354 ft2 750 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC ` / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3000 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 3000 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 110 ft2 0.11 Wood 6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width - Height Sheathing Framing Solar Below o 1 E Exterior Concrete Block - Int Insul Main 4.1 64 8 8 0 517.3 ft2 0 0 0.6 0 2 S Exterior Concrete Block - Int Insul Main 4.1 65 0 8 0 520.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int'Insul Main 4.1 49 0 8 0 392.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 50 9 8 0 406.0 ft2 0 0 0.6 0 5 - Garage Frame - Wood Main 13 30 0 10 0 300.0 ft' 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 5 4 6 8 35.6 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 2 S 2 Vinyl Low-E Double Yes 0.55 0.7 N 35.6 ft2 12 ft 4 in 1 ft 0 in None None 3 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 4 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 5 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 19.5 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 6 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 64.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 7 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 4 in 2 ft 6 in Drapes/blinds Exterior 5 8 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 1 ft 4 in 0 ft 6 in None None 9 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 5.3 ft2 4 ft 3 in 1 ft 0 in None None 10 N 4 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 4 ft 3 in 3 ft 6 in None None 11 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 448 ft2 448 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000378 2975 163.22 306.42 .1294 7 6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORRA R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 45.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split S]ngl SEER: 15 47.5 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 600 ftz Main 150 ft' Proposed Qn Main --- cfm 135.0 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Venting an f X Jan Feb Feb H HX Mar Mar Apr Apr May May Jun Jun rl Jul Jul rl u Mug Aug Se Sep ri Oct Oct Nov Nov HX Dec Dec H [ Jan Feb Mar [X] Apr [ May Jun Jul Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68, 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main .r 6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 8312 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1835.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 300.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (ft2) 3000 a. Under Attic (Vented) b. Knee R=30.0 3000.00 ft2 Wall (Vented) R=19.0 110.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 142.60 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 600 b. U-Factor: Dbl, U=0.33 97.13 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency C. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 47.5 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 17.25 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.225 ft. a. Electric Heat Pump 45.5 HSPF:8.50 Area Weighted Average SHGC: 0.285 S. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 3000.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Sig Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/9/2021 3:24 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1