HomeMy WebLinkAboutENERGY EFFICIENCY CODEAl
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE "FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 13 Phase 3 Waterstone 2508
Builder Name:, ADAMS HOMES
Street: 8348 Amamlfi Circle
Permit Office:
City, State, Zip: Port Saint Lucie, FL
, 34951
Permit Number:
.Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO. INTL
County: St. Lucie (Florida Climate Zone 2 )
1, New construction or existing
New (From Plans)
10..: Wall Type01928.0 sgft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block + Int Insul, Exterior
R=4.1 : 1656.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
c. N/A
R=13.0 272.00 ft2
R= ft2
4. Number of Bedrooms
4
d. N/A
R= f:2
5. Is. this a worst case?
No;
11. Ceiling Types (2623.0 sqft.)
I Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ftz
6. Conditioned floor area above grade (ft2)
2523
b. Knee Wall (Vented)
R=19.0 100.00 ft.
Conditioned floor area below grade: (ft2
0
c. N/A
R= ft2
7. Windows(314.9 sgft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
70.92 ft2
13. Cooling systems
-kBtu/hr Efficiency .
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
C. U-Factor: DbI, U=0.55
. 51.11 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth:
7.057 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.30g
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights
:Area
c. U-Factor.(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2523.0 sgft.)
Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation
R=0.0 2523.00 ft2
b. Conservation features
b. N/A
R= . ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.125
Total Proposed Modified Loads: 70.25
PASS
Total Baseline
Loads: 70.50
I hereby certi that the plans
Y fY p
icafi covere '�
Revi of the plans and
O
this calculation are in comp'. n
�'ons
e lor' ergy
specifications covered by this
Code.
calculation indicates compliance
�� rn���✓'',� �,�.�> A�i+
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
r `
DATE: n4-15_9n91 Winn
Keponnny
this building will be inspected for
V
"hereby
compliance with Section 553.908::.
_
I certify that this building, as designed,
is in compliance
Florida Statutes.
,► ,; ,
with the Florida Code.
OWNER/AGENT:
-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
^' envelope leakage test report With envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,. is not greater than 0.050 Qn for whole house.
.4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
en
FORM 13405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Lot 13 Phase 3 Waterstone 2 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 2523
Lot #
13 Phase 3
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8348 Amamlfi Circle
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Port Saint Lucie ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter ummer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2523 20184
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 20184 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ----
0.44 0 0.56
ROOF
/
Roof Gable Roof
Red Solar SA Emitt
Emitt Deck Pitch
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2523 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
100 ft2 0.11
Wood
4/15/2021 4:32 PM - - EnergyGauge® USA 7.0.00 - F1aRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R-Anq-2n2n INPI IT All IMMAPY rWl=r-ICI ICT 011=113na?T
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar Below
1
NE Exterior
Concrete Block - Int Insul
Main
4.1
48
6
8 0
388.0 ft2
0
0 0.6
0
2
SE Exterior
Concrete Block - Int Insul
Main
4.1
32
6
8 0
260.0 ft2
0
0 0.6
0
3
SW Exterior
Concrete Block - Int Insul
Main
4.1
51
0
8 0
408.0 ft2
0
0 0.6
0
4
W Exterior
Concrete Block - Int Insul
Main
4.1
5
0
8 0
40.0 ft2
0
0 0.6
0
5
NW Exterior
Concrete Block - Int Insul
Main
4.1
37
6
8 0
300.0 ft2
0
0 0.6
0
6
- Garage
Frame - Wood
Main
13
34
0
8 0
272.0 ft2
0
0.23 0.01
0
7
NW Exterior
Concrete Block - Int Insul
Main
4.1
18
0
8 0
144.0 ft2
0
0 0.6
0
8
NE Exterior
Concrete Block - Int Insul
Main
4.1
8
6
8 0
68.0 ft2
0
0 0.6
0
9
SW Exterior
Concrete Block - Int Insul
Main
4.1
6
0
8 0
48.0 ft2
0
0 0.6
0
1
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE
Insulated
Main
None
.25
3
6 8
20 ft2
2 -
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 8
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
25 ft 0 in 0 ft 10 in
Drapes/blinds
None
2
NE 1
Vinyl
Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3
SE 2
Vinyl
Low-E Double
Yes
0.33
0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4
SE 2
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5
SE 2
Vinyl
Low-E Double
Yes
0.33
0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
None
6
SE 2
Vinyl
Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
None
7
SW 9
Vinyl
Low-E Double
Yes
0.55
0.7
N
15.6 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
8
SW 3
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
9
SW 3
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
10
W 4
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
None
11
NW 5
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
12
NW 5
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
None
13
NW 7
Vinyl
Low-E Double
Yes
0.33
'0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
None
14
NW 5
Vinyl
Low-E Double
Yes
0.33
0.23
N
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
None
15
SE 2
Vinyl
Low-E Double
Yes
0.33
0.31
N
6.0 ft2
1 ft 4 in
1 ft 0 in
None
None
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 620 ft2
620 ft2
64 ft
8 ft
1
4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
RM
INPUT SUMMARY CHECKLIST REPORT
# Scope Method
~ 1 Wholehouse Proposed ACH(50)
#
System Type
1
Electric Heat Pump/
#
System Type
1
Central Unit/
#
System Type SubT
1
Electric None
FSEC
Cert # Company Name
None
None
INFILTRATION
SLA
CFM 50 ELA EgLA ACH
ACH 50
.000356
2354.8 129.19 242.54 .1263
7
HEATING SYSTEM
Subtype
Speed Efficiency Capacity
Block
Ducts
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
ype Location
EF Cap Use SetPnt
Conservation
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
System Model # Collector Model # Area
Volume
FEF
ft2
DUCTS
/ ---- Supply
----
---- Return ---
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat
Cool
1 Attic 6
503.2 ft
Main 125.8 ft
Proposed Qn
Main
--- cfm
126.2 cfm 0.05
0.60
1
1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Heating
Jan
f X Jan
Feb
f X� Feb
Mar
Mar
E
Apr
Apr
May
May
X Jun
Jun
Jul
Jul
ri
u
u
Mug
Se
Sep
ri
Oct
Oct
Nov
Nov
Dec
Dec
Venting
[ Jan
[ Feb
XMar
[X]
A r
Ma
Jun
Jul
Se
[X] Oct
X Nov
Dec
4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPI IT RI IMMARV rI4I=rIf1 ICT DPDnDT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Main
4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORKV R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8348 Amamlfi Circle, Port Saint Lucie, .FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1656.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
272.00 ftz
c. N/A
R=
ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No'
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ftZ
6. Conditioned floor area (ftz)
2523
b. Knee Wall (Vented)
R=19.0
100.00 ftz
7. Windows- Description
Area
c. N/A
R=
ftz
a. U-Factor: Dbl, U=0.33
166.06 ftz
12. Ducts, location & insulation level
R ftz
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33
70.92 ftz
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
51.11 ftz
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U,Factor: other (see details)
26.83 ftz
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
7.057 ft.
a. Electric Heat Pump
p
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.309
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft z
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation.
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2523.00 ftz
Credits (Performance method)
Pstat
b. N/A.
R=
ftz
c. N/A
R=
ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new.EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature ��✓ _ Date:
Address of New Home: City/FL Zip:
"Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
a mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1