Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEAl FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE "FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 13 Phase 3 Waterstone 2508 Builder Name:, ADAMS HOMES Street: 8348 Amamlfi Circle Permit Office: City, State, Zip: Port Saint Lucie, FL , 34951 Permit Number: .Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO. INTL County: St. Lucie (Florida Climate Zone 2 ) 1, New construction or existing New (From Plans) 10..: Wall Type01928.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block + Int Insul, Exterior R=4.1 : 1656.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=13.0 272.00 ft2 R= ft2 4. Number of Bedrooms 4 d. N/A R= f:2 5. Is. this a worst case? No; 11. Ceiling Types (2623.0 sqft.) I Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftz 6. Conditioned floor area above grade (ft2) 2523 b. Knee Wall (Vented) R=19.0 100.00 ft. Conditioned floor area below grade: (ft2 0 c. N/A R= ft2 7. Windows(314.9 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 13. Cooling systems -kBtu/hr Efficiency . SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 C. U-Factor: DbI, U=0.55 . 51.11 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 7.057 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.30g a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights :Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2523.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 b. Conservation features b. N/A R= . ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.125 Total Proposed Modified Loads: 70.25 PASS Total Baseline Loads: 70.50 I hereby certi that the plans Y fY p icafi covere '� Revi of the plans and O this calculation are in comp'. n �'ons e lor' ergy specifications covered by this Code. calculation indicates compliance �� rn���✓'',� �,�.�> A�i+ with the Florida Energy Code. PREPARED BY: Before construction is completed r ` DATE: n4-15_9n91 Winn Keponnny this building will be inspected for V "hereby compliance with Section 553.908::. _ I certify that this building, as designed, is in compliance Florida Statutes. ,► ,; , with the Florida Code. OWNER/AGENT: - BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an ^' envelope leakage test report With envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,. is not greater than 0.050 Qn for whole house. .4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 en FORM 13405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 13 Phase 3 Waterstone 2 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2523 Lot # 13 Phase 3 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8348 Amamlfi Circle Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Port Saint Lucie , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter ummer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2523 20184 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 20184 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ft2 ---- 0.44 0 0.56 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2523 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 100 ft2 0.11 Wood 4/15/2021 4:32 PM - - EnergyGauge® USA 7.0.00 - F1aRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R-Anq-2n2n INPI IT All IMMAPY rWl=r-ICI ICT 011=113na?T WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ft2 0 0 0.6 0 2 SE Exterior Concrete Block - Int Insul Main 4.1 32 6 8 0 260.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 51 0 8 0 408.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 5 NW Exterior Concrete Block - Int Insul Main 4.1 37 6 8 0 300.0 ft2 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.23 0.01 0 7 NW Exterior Concrete Block - Int Insul Main 4.1 18 0 8 0 144.0 ft2 0 0 0.6 0 8 NE Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ft2 0 0 0.6 0 9 SW Exterior Concrete Block - Int Insul Main 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 1 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 8 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 3 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ft2 13 ft 0 in 0 ft 6 in None None 4 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 13 ft 0 in 2 ft 10 in None None 5 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 7 ft 4 in 1 ft 4 in Drapes/blinds None 6 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds None 7 SW 9 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 8 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 9 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 10 W 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds None 11 NW 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 10 in 0 ft 10 in Drapes/blinds None 12 NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds None 13 NW 7 Vinyl Low-E Double Yes 0.33 '0.23 N 30.0 ft2 9 ft 10 in 0 ft 4 in Drapes/blinds None 14 NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 2 in Drapes/blinds None 15 SE 2 Vinyl Low-E Double Yes 0.33 0.31 N 6.0 ft2 1 ft 4 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ft2 620 ft2 64 ft 8 ft 1 4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 RM INPUT SUMMARY CHECKLIST REPORT # Scope Method ~ 1 Wholehouse Proposed ACH(50) # System Type 1 Electric Heat Pump/ # System Type 1 Central Unit/ # System Type SubT 1 Electric None FSEC Cert # Company Name None None INFILTRATION SLA CFM 50 ELA EgLA ACH ACH 50 .000356 2354.8 129.19 242.54 .1263 7 HEATING SYSTEM Subtype Speed Efficiency Capacity Block Ducts Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM ype Location EF Cap Use SetPnt Conservation Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage System Model # Collector Model # Area Volume FEF ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 126.2 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Jan f X Jan Feb f X� Feb Mar Mar E Apr Apr May May X Jun Jun Jul Jul ri u u Mug Se Sep ri Oct Oct Nov Nov Dec Dec Venting [ Jan [ Feb XMar [X] A r Ma Jun Jul Se [X] Oct X Nov Dec 4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPI IT RI IMMARV rI4I=rIf1 ICT DPDnDT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORKV R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 8348 Amamlfi Circle, Port Saint Lucie, .FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1656.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 272.00 ftz c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No' 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftZ 6. Conditioned floor area (ftz) 2523 b. Knee Wall (Vented) R=19.0 100.00 ftz 7. Windows- Description Area c. N/A R= ftz a. U-Factor: Dbl, U=0.33 166.06 ftz 12. Ducts, location & insulation level R ftz SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 b. U-Factor: Dbl, U=0.33 70.92 ftz SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 51.11 ftz a. Central Unit 42.0 SEER:15.00 SHGC: SHGC=0.70 d. U,Factor: other (see details) 26.83 ftz SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 7.057 ft. a. Electric Heat Pump p 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.309 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft z a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 b. Conservation features 9. Floor Types Insulation. Area None a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftz Credits (Performance method) Pstat b. N/A. R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new.EPL Display Card will be completed based on installed Code compliant features. Builder Signature ��✓ _ Date: Address of New Home: City/FL Zip: "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient a mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/15/2021 4:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1