HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 177 Phase 3 Waterstone 1780 BGR
Builder Name: ADAMS HOMES
Street: 5331 Vespera Street
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: - St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Typeol512.6 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1244.60 ft2
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.4 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 356
a. U-Factor: Dbl, U=0.33 113.31 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 46.31 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 3.357 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1780.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features -
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 52.52
Glass/Floor Area: 0.100
PASS
Total Baseline Loads: 52.92
I hereby certify that the plans s ications covered
Revj'ft of the plans and
64ri
this calculation are in comps a on ergy
specifications covered by this
:���HB
4
' p
Code.
calculation indicates compliance
with the Florida Energy Code.
am ��, •,;: ,,,,,�°�,�0.
PREPARED BY:
Before construction is completedtv
DATE: 118-f7-217121 Winn Kenmany
this building will be inspected for
compliance with Section 553.908
'
I herebycertify that this building, as designed, is in compliance
fY 9, 9 P
Florida Statutes.
'�• • . �'
with the Florida_F�� ode.
CQI) ytiiy'1'��'
OWNER/AG
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
6/7/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 177 Phase 3 Waterstone Bedrooms: 3
User Conditioned Area: 1780
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 177
Block/Subdivision: Waterstone
PlatBook:
Street: 5331 Vespera Street
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
.BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2
---- 0.38 0 0.62
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1990 ftZ 446 ft2 Medium
N
0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1780 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1780 ft2 0.11 Wood
120 ft2 0.11 Wood
6/7/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPI IT SI IMMARV rWI= '-KI IST RFPnPT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
1 E
Exterior Concrete Block - Int Insul
Main
4.1 40 0 8
0
320.0 ft2
0
0 0.6
0
2 S
Exterior Concrete Block - Int Insul
Main
4.1 40 6 8
0
324.0 ft2
0
0 0.6
0
3 SW
Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
4 W
Exterior Concrete Block - Int Insul
Main
4.1 11 9 9
6
111.6 ft2
0
0 0.6
0
5 NW
Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
6 N
Exterior Concrete Block - Int Insul
Main
4.1 54 0 8
0
432.0 ft2
0
0 0.6
0
7
Garage Frame - Wood
Main
13 33 6 8
0
268.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W Insulated Main
None
.25
3
6 8
20 ft2
2
Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E 1 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
12 ft 0 in
0 ft 10 in
None
None
2
E 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
S 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
4
SW 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
5 ft 6 in
0 ft 10 in
Drapes/blinds
Exterior 5
5
W 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.6 ft2
4 ft 6 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
NW 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
5 ft 6 in
0 ft 10 in
Drapes/blinds
Exterior 5
7
N 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
391 ft2 391 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgI-A
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Sing] HSPF:8.5
28.2 kBtu/hr
1
sys#1
6/7/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FOFVM R405-2020 INPUT SUMMARY CI-IFCKI IAT RFPf1RT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing] SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 356 ftz
Main
89 ftz Proposed Qn
Main
--- cfm
106.8 cfm 0.06
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
Heatinf X� Jan Feb
Mar
Mar
A r
APr f
Jul
May
May rjJun r1j.,
Jun Jul
Au
AuSep
rj
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
Ventin [ Jan Feb
X Mar
X
A r [
Ma Jun
Aug
Se
[X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftZ
0 ft
0.3
Main
6/7/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5331 Vespera Street, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1244.60 ft2
b. Frame - Wood, Adjacent
R=13.0
268.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1780.00 ft2
6. Conditioned floor area (W)
1780
b. Knee Wall (Vented)
R=19.0
120.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
46.31 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
3.357 ft.
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 5:00 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1