HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM Joseph
Bravo:A 1410D0000
A
PV SYSTEM SUMMARY: 11 .520 KW CITY NOTES: 0177 2C5AD000
1228B
RESIDENTIAL PHOTOVOLTAIC SYSTEM THIS PROJECT COMPLIES WITH THE FOLLOWING:
SYSTEM SIZE (DC) STC: 32 X 360 = 11520W DC
2020 7TH EDITION FLORIDA FIRE PREVENTION CODE Digitally siIned by Joseph J
2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING Bravo:A01 10D00000177CA
PTC: 32 X 335.5 = 10736W DC 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL 32C5AD00 1228B
SYSTEM SIZE (AC) 10000W AC @ 240V 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL Date:2021 8.19 05:39:31
2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING -06'00'
MODULES 32 X LONGI SOLAR: LR4-60HPH-360M 2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS
OPTIMIZERS 32 X SOLAR EDGE: P401 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION
2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING
INVERTER SOLAR EDGE: SE1000OH-USRGM [S11] 2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY
2017 NATIONAL ELECTRIC CODE (NEC)
TILT 20°, 20°, 20' AS ADOPTED BY COUNTY OF ST. LUCIE
AZIMUTH 180°, 90°, 90'
ROOF COMPOSITION SHINGLE
RAFTER/TRUSS SIZE 2X4 TRUSS @ 24" O.C.
ATTACHMENT TYPE UNIRAC: SFM INFINITY MICRORAIL WITH UNIRAC SFM SITE LOCATION:
INFINITY RAIL-LESS AeQ 9 A.Q
MAIN SERVICE PANEL EXISTING 200 AMPS MSP WITH (E) 200 AMPS MAIN 8u^le^d6erde^
Pmperty Qy+t10B MI-k Preyer Teippk
BREAKER ON TOP FED
INTERCONNECTION LINE SIDE TAP 9
OCPD RATING 60 AMPS CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM Meth.
UTILITY FLORIDA POWER & LIGHT CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS
REQUIRED BY FIELD CONDITIONS.
ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE
11
MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR Pm Pe,k "
TABLE OF CONTENTS TO THE SURFACE UPON WHICH THEY ARE MOUNTED.
PV-1 SITE LOCATION AND HOUSE AERIAL VIEW MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN
PV-2 SITE PLAN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED %5
PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE
PV-2A ROOF PLAN WITH MODULES LAYOUT FIELD. SITE LOCATION
PV-3 MOUNTING DETAILS
INSTALLATION NOTES: HOUSE AERIAL VIEW:
PV-4 THREE LINE DIAGRAM
PV-5 EXISTING SERVICE PANEL DIG ALERT (811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION
PV-6 NOTES AND EQUIPMENT LIST SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE
.,
INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK.
PV-7 LABELS EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. it
PV-7A SITE PLACARD CONDUIT TO BE PAINTED ' r
PV-8 OPTIMIZER CHARTw �`'. r
PV-9 & 10 SAFETY PLAN
MODULE LOCATION
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
° freedom CERTIFIED ELECTRICAL CONTRACTOR
F 2 EC13008056 1426 NORTH 35TH STREET, DESIGN SITE LOCATION AND
GREG ALBRIGHT
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY. MJ HOUSE AERIAL VIEW PV-1
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819
Tel:(800)385-1075 I,.. JOB No.: F095054
ROOF AREA : 3802.00 SQ FT (E) MAIN SERVICE PANEL
Joseph J
PV SYSTEM (E) UTILITY METER
Bravo:A01410D
11.520 kW-DC 135'-2" 0000017 CA32
10.000 kW-AC _ _ _ _ _ _ _ SIC_ C5AD00 1228B
Digitally signed by
Joseph J
Bravo:A0141 D000001
77CA32C5A 0001228B
c� Date:2021.0 .19
05:39:45-06' 0'
I I
(N)JUNCTION BOX
Z
O
2
w
U1 I 15'-5"
A (N) UTILITY DISCONNECT SQUARE D
= DRIVEWAY D222NRB
(N)SOLAREDGE SE1000OH-USRGM
,ZJ [S11] INVERTER WITH RAPID
m SHUTDOWN
m j. I
LLo
0
0 o
I I
I I
52'-4"
I I
(N)32 LONG SOLAR: LR4-60HPH-360M
PROPERTY LINE
135-1
r
SITE PLAN 1
SCALE: 1"=20'
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
freedomCERTIFIED ELECTRICAL CONTRACTOR
F O R F V F R EC13008056 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY: MJ
GREG ALBRIGHT SITE PLAN PV-2
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 `f�� JOB NO.: F095054
ROOF AREA STATEMENT
ROOF AREA : 3802 SQ FT SYSTEMROOF MODULES PITCH AZIMUTH ROOF AREA ARRAY AREA ARRAY DISTRIBUTED `�\Pio0 yVR"q FL
QTY COVERAGE % E fill •�j'�
PV SYSTEM WEIGHT
11.520 kW-DC 1 13 20° 180° 634.4 SQ FT 255.45 SQ FT 16.54% 2.19 PSF
10.000 kW-AC 2 10 20° 90° 702.3 SQ FT 196.50 SQ FT _ No. _
3 9 20° 90° 373.5 SQ FT 176.85 SQ FT
/Ems:,
UM ,0• STATE O F
FtORIDP•'
FIRE ACCESS '"� ;S/6NAI-V
PATHWAYS FIRE ACCESS By Yuri at 5:48:43 AM,8/19/2021
r; PATHWAYS This item has been digitally signed and sealed by
Yurianto Yurianto on the date adjacent to the
seal. Printed copies of this document are not
considered signed and sealed and the signature
01 must be verified on any electronic copies.
01,
Digitally signed by Vunanto
vunanto
Yurianto °"°n=Y°nanto Vunanto°=l1B
°-Unafrllaled
ou=A 01410D00000176B07CBF
Yurianto d a°mega theautborolthis
Location:
Dale:2021-08-19 05:49-05:00
T-0"
LEGEND:
11 OBSTRUCTION
JB O PIPE VENT
MODULES
O
CONDUIT
® SETBACK
Ac AC
FIRE ACCESS DISCONNECT
PATHWAYS MSP MAIN SERVICE
PANEL
JUNCTION
J g BOX
INv INVERTER
0
M unn UTILITY
METER
NOTES:
1. EMT CONDUIT ATTACHED TO FIRE ACCESS
THE ROOF USING CONDUIT PATHWAYS FIRE ACCESS
PATHWAYS
MOUNTS
2. ATTACHED CLAMPS AT 25%
FROM THE EDGE AND 50% FROM 01
THE CENTER OF THE MODULES 01' ROOF PLAN i
3. JUNCTION BOX IS MOUNTED TO (N) 32 LONGI SOLAR: LR4-60HPH-360M SCALE: 3/32" _ 1 1-019 1
THE RAIL.
CLIENT: REVISIONS: TITLE: SHEET:
' freedom ELECTRICAL ELECTRICAL
WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F 0 R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN M J ROOF PLAN W/ p\/ /�
FREEDOM FOREVER FLORIDA LLC GREG ALBRIGHT FORT PIERCE, FL 34947 BY: MODULES LAYOUT r V—2~
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819
Tel:(800)385-1-1075 JOB NO.: F095054
\0111111111111 FL
�PN�0 YV R!q
�,.�\CENSF �IO%
* No.86261
,0 STATE OF
�i FGORID --'CX .`
SFM TRIMRAIL SFM MICRORAIL //rt11111j1\\
LONGI SOLAR: LONGI SOLAR: By Yuri at 5:48:45 AM,8/19/2021
LR4-60HPH-360M LR4-60HPH-360M
SFM SLIDER AND This item has been digitally signed and sealed by
TRIMRAIL ROOF Yurianto Yurianto on the date adjacent to the
ATTACHMENT ROOF/DECK MEMBRANE seal. Printed copies of this document are not
2.5" ROOF DECK/ 2.5" considered signed and sealed and the signature
MEMBRANE must be verified on any electronic copies.
2.5"MIN.EMBED. FLASHING 2.5"MIN.EMBED. UNIRAC SLIDERS NOTE:
Digitally signed by Vurianlo Vurianlo
5/16"STAINLESS STEEL LAG Yu ri a nto DN:cn=v"ianlov"rianlo=5
=unamuiaced
FLASHING _A01410D00000176BO7CBF25000
BOLWITTORS2"MIN.EMBEDAL MENT
5/16"STAINLESSSTEEL BLOCKING UPGRADE REQUIRED IN ROOF °"'A2
WITH 2-1/2"MIN.EMBEDMENT dog"ma",
AND FLAT WASHER LAG BOLT OR Yurianto a nto LOCa. am`edn`o`o`15
STRUCTURAL SCREW 1&3 (HIP ROOFS) Date:2021-08-190549-05:00
WITH 2-1/2"MIN.
EMBEDMENT AND FLAT
WASHER
BUILDING STRUCTURE
BUILDING STRUCTURE
ATTACHMENT DETAIL
w:
Scale: NTS 2
f
I I I I
Module I
SFM MICRORAIL (Roof Zones) I 1 I 1 1 1
I I I I I 1
I I 1
Zone 1 I I 1
0 Zone 2 I 1 1
I I I 1
Zone 3
LONGI SOLAR. z5 MNEMO�O i 1
LR4-60HPH-360M 1
I
FLASHING I I
1 1
UNIRAC SLIDERS I 1
SFM Components 1 1
ROOF/DECK MEMBRANE 1 1
0 SFM Microrail 2" I 1
an SFM Splice 6.S" 1 1
SFM TRIMRAIL I 1
SFM Attached Splice 8" I 1
SFM Trim Attachment I 1
SFM Trim Univ Clip I 1
2X4 TRUSS @ 24"O.C. 0 Full Trim Section I 1
I 1
Cut Trim Section I 1
I 1
EMekv SFM SLIDER AND TRIMRAIL MAX ATTACHMENT SPAN — 41
25,M41 ROOF ATTACHMENT
FLASHING
5/16"STAINLESS STEEL LAG
BOLT OR STRUCTURAL SCREW
WITH 2-1/2"MIN.EMBEDMENT
AND FLAT WASHER
SOLAR PV ARRAY SECTION VIEW PARTIAL ROOF FRAMING PLAN
Scale: NTS Scale: NTS
CLIENT: REVISIONS: TITLE: SHEET:
• freedom ELECTRICAL ELECTRICAL
WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F O R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN MOUNTING
GREG ALBRIGHT
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY. MJ DETAILS PV-3
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 It
`f�� JOB NO.: F095054
BACKFEED FUSE SIZING CONDUCTOR AMPACITY DE-RATE CALCULATION
MAX. CONTINUOUS OUTPUT 42A @ 240V CONDUCTOR AWG WIRE NEC FACTORS NEC FACTORS CONDUCTOR NEC FACTORS
EQUIPMENT WIRE LOCATION TABLE TABLE AMPACITY TABLE
42.00 X 1.25 = 53AMPS 60A FUSES-OK QTY. SIZE 310.15(B)(16) 310.15(B)(2)(a) @90C ADJ. 310.15(B)(3)(a)
1 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 6 65 0.94 61.1 1.00
2 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 65 0.94 61.1 1.00
PV SYSTEM Joseph J l
by Joseph J
11.520 kW-DC Bravo:AO14 Bravo:AC 1410D0
10.000 kW-AC
10D000001 0000177 A32C5
77CA32C5A AD0001 2 8 B
Date:20 1.08.19
D0001228B 05:40:05-06'00'
(E)200A RATED O'ME'TE',
ILITY
MAIN SERVICE PANEL R
PID
1 PH,120/240V 60HZ
(E)200A/2P
STRING-1 MAIN BREAKER
16 LONGI SOLAR: (END FED)
LR4-60HPH-360M
SOLAREDGE P401
POWER OPTIMIZERS
2-#10 AWG, (N)LINESIDE TAP VIA UL
r-- PV WIRE LISTED CONNECTORS
_ _ _ (N)SOLAREDGE
SE1000OH-USRGM[SI11
I INVERTER
ACSTRING-2 (N)60A FUSED
I 16 LONGI SOLAR: AC DISCONNECT
LR4-60HPH-360M
SQUARE D D222NRB •
2-60 AMP FUSES •
JUNCTION OVERHEAD UTILITY
BOX 0.fb • FEED
SHUTDOWN
F— ----� 4-#10 AWG,THWN-2 SWITCH
1-#8 EGC,THWN-2L 3-#6 AWG,TH W N-2 3-#6 AWG,THWN-2
_ IN 3/4"OR 1-#8 EGC,THWN-2 IN 3/4"OR LARGER EMT CONDUIT
I I LARGER EMT CONDUIT IN 3/4"OR LARGER EMT CONDUIT
I 1
SOLAREDGE P401 J 1-#6 GEC,BARE COPPER
POWER OPTIMIZERS FREE AIR BONDED
2-#10 AWG,PV WIRE EXISTING UFER TIE IN
1-#6 AWG IN FREE AIR OR A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDE
#8 AWG MUST BE IN EMT CONDUIT TAP IN THE MAIN SERVICE PANEL.THIS IS DEPENDENT UPON SITE CONNECT TO EXISTING LIFER
CONDITIONS.
NOTE:
CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED
ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT
TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS
CLIENT: REVISIONS: TITLE: SHEET:
freedom ELECTRICAL ELECTRICAL
WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F 0 R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN
MJ THREE LINE
BY:
FREEDOM FOREVER FLORIDA LLC GREGALBRIGHT FORT PIERCE, FL 34947 PV-4
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 DIAGRAM
Tel:(800)385-1075 � I I I
JOB NO.: F095054
L
I
F.-W-MW
r }
Jose h J Digitally signed by
p Joseph J
Bravo:AO141 OD Bravo:A01410D0000017
00000177CA32 7CA32C5AD0001228B
k Date:2021.08.19
C5AD0001228Bo5:40:18-06'00'
I 1
G,
WIC
E I` A.
CLIENT: REVISIONS: TITLE: SHEET:
freedom ELECTRICAL CALTRICALCONTRACTORNO WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F O R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN EXISTING SERVICE
GREG ALBRIGHT
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY. MJ PANEL PV-5
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 It
`f�� JOB NO.: F095054
GENERAL NOTES:
32 LONGI SOLAR WIRED AND LISTED TO UL1703 STANDARDS
THE SOLAREDGE INVERTER IS INTEGRATED WITH DC DISCONNECTION AND ARC FAULT PROECTION.IT IS ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS W/GROUND FAULT PROTECTION&LISTED TO UL 1741 STANDARDS.
PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A).
SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART.690 OF THE 2017 NEC
CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1 INCH FROM TOP OF THE ROOF TO BOTTOM OF RACEWAY.TABLE NEC 310.15(B)(3)(C)
PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET--AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES WALLS OR BARRIERS--WITH
MINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING:WARNING:PHOTOVOLTAIC POWER SOURCE. Digitally signed by
SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THE REQUIREMENTS OF 2017 NEC Joseph J
Joseph J
THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER Bravo:AO141 ODO Bravo:Ao141 ODOD00017
UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM 00001 77CA32C5 7CA32GAD000 228B
TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION Date:2021.08.19
SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS AD0001228 B 05:40:36-06'00'
SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY)AND UL 1741 STANDARDS
MATERIAL LIST:
QTY. PART PART# DESCRIPTION
32 MODULES 114-36OW LONGI SOLAR:LR4-60HPH-360M
32 OPTIMIZERS 130-401 P401 SOLAREDGE POWER OPTIMIZER-FRAME MOUNTED MODULE ADD-ON
1 JUNCTION BOX 480-276 60OVDC NEMA 3R UL LISTED JUNCTION BOX
2 CONNECTORS 240-300 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) BREAKER SIZES:
2 CONNECTORS 240-301 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE)
1 INVERTER 120-103 SE1000OH-USRGM[SI11 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN
1 AC DISCONNECT 323-065 60A RATED 240VAC NEMA 3R UL LISTED
2 FUSES 330-060 60A FUSE 1 PH 240VAC
1 FUSE REDUCER 330-510 10OA-60A FUSE REDUCER
1 TAP KIT 350-110 3/0 3 PORT INSULATED TAP
58 ROOF ATTACHMENT 1 261-602 UNIRAC:SFM INFINITY MICRORAIL
56 MICRORAIL 1 261-602 SFM MICRORAIL 2 INCH
23 SFM TRIM 1 241-253 FLASHKIT SFM TRIM COMP DARK
61 SFM SLIDER 1 261-603 FLASHKIT SFM SLIDER COMP DARK
18 BONDING CLAMP 1 221-100 SFM N/S BONDING CLAMP
7 BONDING CLAMP 1 241-404 SFM TRIM BONDING CLAMP
34 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY
19 SFM SPLICE 1 261-604 SFM SPLICE
5 SFM ATTACHED SPLICE 1 211-101 SFM ATTACHED SPLICE 8 INCH
27 TRIMRAIL 1 261-606 SFM TRIMRAIL UNIV CLIP W/HDW
8 TRIM SPLICE 1 261-605 SFM TRIM SPLICE DIRK
14 TRIMRAIL 1 211-115 SFM TRIMRAIL UNIV DIRK
32 GROUND LUG 1 260-585 ILSCO GROUND LUG
32 TRIM END CAPS 1 UNIRAC SFM TRIM END CAPS
SERVICE:
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
freedomCERTIFIED ELECTRICAL CONTRACTOR
F O R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN MJ NOTES AND
FREEDOM FOREVER FLORIDA LLC GREG ALBRIGHT FORT PIERCE, FL 34947 BY: EQUIPMENT LIST PV-6
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 `f�� JOB NO.: F095054
NOTES:
. 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS
SHOWN HEREON.
POWER • OUTPUT DUAL POWER SOURCES2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:
YY A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR
CONNECTION SECOND SOURCE IS PHOTOVOLTAICMACHINE PRINTED LETTERS OR ELECTRO-PLATING.
DO NOT • 1 AC • B. RED BACKGROUND COLOR WHITE TEXT AND LINE
OVERCURRENT DEVICE. AC NORMAL
■ OPERATING
■ VOLTAGE ' • WORK.
LTS C. AERIAL FONT.
705.12(B)(2)(3)(b) 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN
690.54 THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE
HAND-WRITTEN.
SOLAR PV SYSTEM EQUIPPED 3. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH
WITH RAPID SHUTDOWN POP-RIVETS OR SCREWS.
TURN RAPID
SHUTDOWN SWITCH TO
THE "OFF" POSITION TO
SHUT DOWN PV SYSTEM PVPpEs "WAR
Joseph J Digitally signed
by Joseph J
AND REDUCE SHOCK Bravo:A014 Bravo:A01410D0
HAZARD IN THE ARRAY ELECTRICAL TERMINALS • : • SHOCK 1 • 1 HAZARD. 1 A 10D000001 0000177CA32C5
690.56(C)(1)(A)
77CA32C5 AD0001228B
' - •1 ' ' • • Date: 2021.08.19
D0001 228B 05:40:53 -06'00'
a 690.13 (B)
I
PV SYSTEM DC DISCONNECT'
VOLTAGE:MAXIMUM :I
PV SYSTEM AC DISCONNECT
MAX RATED OUTPUT CURRENT OF
< RATED AC OUTPUT CURRENT - 42.00 AMPS THE CONTROLLER OR DC-TO-DC
AC NORMAL OPERATING V• VOLTS
690.15, 690.54 690.53
I I
ARRAY
RAPID SHUTDOWN SWITCH FOR
SOLAR
� — — INVERTER L
DC J/B
690.56(C)(3)
71
NEC 690.31(G)(3)&(4)
WARNING"
IPHOTOVOILTAIC POWER SOURCE
EVERY 10' ON CONDUIT AND ENCLOSURES
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
freedomCERTIFIED ELECTRICAL CONTRACTOR
EC13008058 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC GREGALBRIGHT FORT PIERCE, FL 34947 BY: MJ LABELS PV-7
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819
Tel:(800)385-1075 JOB NO.: F095054
Joseph J Digitally signed
Bravo:A014 byJosepn
Bravo:A01 10D
10D000001 000001 77C A32C
77CA32C5A 5AD00012 86
Date: 2021 08.19
CAUTION: D0001228B o5:41 :08 -0 '00'
MULTIPLE SOURCES OF POWER LOCATED AS SHOWN.
DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES
MAIN SERVICE PANEL
UTILITY METER
AC DISCONNECT
JUNCTION BOX
INVERTER EQUIPPED
WITH RAPID SHUTDOWN
H
W
W
H
2
H
M
2
H
O
Z
32 PV MODULE
6X8"TYP-NEC 705.10
NOTES:
1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON.
2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:
A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR
ELECTRO-PLATING.
B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.
C. AERIAL FONT.
3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED.
SIGNAGE CANNOT BE HAND-WRITTEN.
3. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.
CLIENT: REVISIONS: TITLE: SHEET:
freedom ELECTRICAL ELECTRICAL
WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F O R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY: MJ
GREG ALBRIGHT SITE PLACARD Pv_7A
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 `f�� JOB NO.: F095054
1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 SOLAREDGE OPTIMIZER CHART
1
2
3
4
5
6
7
8
9
10
CLIENT: REVISIONS: TITLE: SHEET:
' freedom ELECTRICAL ELECTRICAL
WARREN WALKER DESCRIPTION DATE REVISION
DATE: 8/18/2021
CERTIFIED ELECTRICAL CONTRACTOR
F 0 R E V E R EC13008058 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY: MJ OPTIMIZER PV-8
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 GREG ALBRIGHT CHART
Tel:(800)385-1075 JOB NO.: F095054
SAFETY PLAN MARK UP KEY
INSTRUCTIONS:
1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. O PERMANENT ANCHOR
2. SAFETY PLAN MUST BE MARKED BEFORE JOB
STARTS AS PART OF THE PRE-PLAN OT TEMPORARY ANCHOR
3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE
& MAKE NOTES ON THE JHA SHEET
IL IN CASE OF EMERGENCY INSTALLER LADDER
NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC JUNCTION / COMBINER BOX
NAME: STUB-OUT
ADDRESS:
SKYLIGHT
SAFETY COACH CONTACT INFORMATION z
NAME: NO LADDER ACCESS (STEEP GRADE
0 OR GROUND LEVEL OBSTRUCTIONS)
ADDRESS:
ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE RESTRICTED ACCESS
SAFETY PLAN AND SIGN INDICATING THAT THEY ARE
AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR CONDUIT
WORKING SAFELY.
NAME SIGNATURE
GAs GAS SHUT OFF
HZo WATER SHUT OFF
O SERVICE DROP
O POWER LINES
DATE: TIME:
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
freedomCERTIFIED ELECTRICAL CONTRACTOR
EC13008056 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY: MJ SAFETY PLAN PV-9
GREG ALBRIGHT
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 A
Tel:(800)385-1075 �1 JOB NO.: F095054
JOB HAZARD ANALYSIS
Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture
Ladder Access Public Protection Weather and Environment Restroom facilities
• Ladders must be inspected before each use. • The safety of the Client and the Public must be maintained at all • The site supervisor shall forecast the weather conditions at the 0 Employees shall have access to restroom facilities with
• Extension ladders must be set up on a firm and level surface at times. job site, prior to crew arrival, in order to mitigate any hazards hand-washing stations. Use of onsite restroom is at the client's
a 4-to-1 rise to run angle(or 75 degrees)and the top must be 0 The Client and the Public shall be prevented from entering the associated with inclement weather(heat, cold,wind, rain, etc.) discretion (location is annotated below). If client does not give
secured to the structure. Extension style ladders placed on work zone through the use of barriers and/or signage, as 0 The site supervisor will utilized a portable wind meter permission, location of suitable restroom facilities with
uneven, loose or slippery surfaces must additionally have the required. (anemometer)to verify actual onsite wind conditions, by hand-washing stations offsite will be provided.The onsite
base firmly anchored or lashed so the base will not slip out. 0 Company, Client and Public property shall be protect from checking at the ground and on any elevated work surface(ex, supervisor will identify location and make arrangements to
• Extension ladders must be used with walk-through devices or falling objects. rooftop)prior to work start, at midday and prior to solar panel ensure all employees have access at any point.
the ladder must extend 36"above the stepping off point. • Pets(including dogs)shall be secured by their owners prior to staging on a roof. . Restroom facilities will be(circle one): Onsite-Offsite
• A-frame ladders must only be climbed with the ladder spreader work start. • Elevated work involving the moving or maneuvering of solar • If Offsite, add location name and address:
bars locked in the open position;A-frame ladders shall not be • The client should not leave pets,family members, or others in panels shall cease at 25mph (sustained wind)until wind
climbed while in the closed position (ex, closed and used while the charge or care of Employees, Contractors, or Temporary subsides. Incident Reporting Procedure
leaned against a structure). Workers. • Forecasted weather maximum temp(degrees F): • Contact your Site Supervisor
• Additional notes: • Crew leader responsible for communication with the client:
Name:
Mobile Equipment • Client and public is excluded from work area by barricades (N/A,
• Only Qualified operators will operate equipment; operators must Yes, No). Heat Related Illness Prevention Phone:
maintain a certification on their person for the equipment being • Employees shall have access to potable drinking water that is
operated. Training and Pre-Job Safety Briefing fresh, pure, and suitably cool. The water shall be located as • Contact your Manager
• Type(s)of mobile equipment(Type/Make/Model): • All employees onsite shall be made aware of the specific close as practicable to the areas where employees are working.
hazards of this project and review this HJA during a pre-job Water shall be supplied in sufficient quantity at the beginning of Name:
• Qualified operator(s): briefing, and their signature indicates awareness of site the work shift to provide at least one quart per employee per
conditions and the plan to eliminate any hazards identified prior hour for drinking for the entire shift. Employees may begin the Phone:
Material Handling and Storage to and during the project. shift with smaller quantities of water if they identify the location
• Materials will be staged/stored in a way that does not present a and have effective means for replenishment during the shift to • Contact your Site Supervisor
hazard to client, personnel or public. Materials stored on the Crew leader(name/title): allow employees to drink on quart or more per hour. The
roof will be physically protect from failing or sliding off. r frequent drinking of water shall be encouraged. Name:
• Crew member(name/title): • Shade shall be present when temperature exceeds 80 degrees
Fall Protection Fahrenheit.When the outdoor temperature in the work exceeds Phone:
• A site-specific plan for fall prevention and protection is required • Crew member(name/title): 80 degrees Fahrenheit, employees shall have and maintain one
prior to starting work and must remain onsite at all times until771 or more areas with shade at all times. With: Your full name, phone number, office location, brief description
work is complete; a fall rescue plan must be outlined and • Crew member(name/title): • New employees must be acclimatized. New employees will be of what happen and when.
discussed among the crew prior to work start. 771 monitored by their Crew Leader(site supervisor)for the first two
• First-person-Up (FPU) must install their anchor and connect • Crew member(name/title): (2)weeks of employment or longer when necessary. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE
before any other task, including installing other anchors. The _��] • Employees will be allowed and encouraged to implement (add as many as necessary by using additional sheets)
Last-Person-Down (LPD)must be the only person on a roof • Crew member(name/title): scheduled breaks during each shift. Employees must take
uninstalling fall protection. cool-down breaks in the shade any time they feel the need to do
• FPCP(name and title): Airborne Contaminants: so to protect them from overheating. Supervisors are Define the Hazard: Method/steps to prevent incident:
• Asbestos-containing (Transite)piping (ACP)-Do not disturb REQUIRED to allow employees any break period they need
• FPU and LPD (name and title): (move, drill, cut fracture, etc.) during high heat conditions.
• Asbestos-containing thermal insulation (ACI)and • Cool Vests are encouraged for all employees at all times during
Electrical Safety Asbestos-containing duct wrapping (ACW)-do not disturb, no periods of high heat.
• The Electrical Qualified Person (EQP)is required onsite to attic or crawlspace access is allowed if work to be performed 0 Identify the location of the closet Occupational/Industrial Clinic Define the Hazard: Method/steps to prevent incident:
perform electrical work. could cause exposure to personnel, client or public. or Hospital in case a crew member becomes ill.
• All electrical work will be performed with equipment in an
electrically safe condition (de-energized)unless approval has • If yes, list specific tasks and protection in place: What is the specific plan to provide and replenish sufficient water for
been granted prior to work. all employees on site?
• Service drops and overhead electrical hazards will be • If offsite replenish is necessary,where will you go to replenish Define the Hazard: Method/steps to prevent incident:
indentified and protected from contact, as neccessa . water(location/address):
• EQP(name and tile):
• Who will replenish the drinking water(name):
Define the Hazard: Method/steps to prevent incident:
CLIENT: REVISIONS: TITLE: SHEET:
ELECTRICAL CONTRACTOR NO: WARREN WALKER DESCRIPTION DATE REVISION DATE: 8/18/2021
freedomCERTIFIED ELECTRICAL CONTRACTOR
F O R E V E R EC13008056 1426 NORTH 35TH STREET, DESIGN
FREEDOM FOREVER FLORIDA LLC FORT PIERCE, FL 34947 BY: MJ
GREG ALBRIGHT SAFETY PLAN PV-10
2619 CONSULATE DR SUITE 800,ORLANDO,FL 32819 1
Tel:(800)385-1075 .j�� JOB NO.: F095054
60 LR4-60HPH 350-370M
Design (mm) Mechanical Parameters Operating Parameters
1 1
Call Odarcard m120(6x20) Openni lTemperature:-0 C-+85C
lvxtiur Bac IF68,tireediodes Peeler Output Tolerance:0-+5W
Output Cable:4mm',300mm in length, Vat and 1,Toleanre:13%
length canbeanomized Maximum5ystem vdrage:DasaovPEc/uL)
0 GbsSngegass
L High Efficiency 17
� ith 32mm mated tempered glass Maximum Sedes Fuse Rating:20A
Low • ERC Nominal Operating Cell Temperature:45±2C
r m,e:Anodlsdawminnmaowframe
Half-cut Technology
, , raNenn<e.IT
wmensi 0kg Safetyflass:Class ll
LLUI''''II a Diension:l]76x1052x35mm Fire Rating:UL type f or type2
Ed
u amOnml Packaging:30pa per Pallet
180taa per 20'GP
TFr
7LOpa ,40'HC
PH
Model Number LR4-60HPH-350M LR4-60HPH-355M LR4-60HPH-360M LR4-60HPH-365M LR4-60HPH-370M
Testing Condldon STC I NOCT STCI NOCT STC NOCT ETC NOCT STC I NOCT
Maximum Power(Pmax/VJ) 350 1 259.3 355 1 263.0 360 1 266.7 365 1 270.4 370 1 274.1
1 37.8 40.7 1 38.0 40.9 1 38.2 41.1 I 38.4 41.3 385
1 .
Processing;10-year Warranty for Materials and 25-year Warranty for Extra Linear Open Circuit Voltage(Voc/V) 40.5-0.55% 1 r r Short CircuitCurrent(Isc/A) 11.02 8.89 11.10 8.95 11.20 9.03 28 9.09 11.37 I 9.17
100%
26-year Power Voltage at Maximum Power(Vni 33.3 30.8 315 30.9 33.7 31.1 33.9 31.3 34.1 3L5
AtltlifionalV leer Current a n
lar's Linear Warra WarraOn SA%nnual Module t Mai um Power(Imp/A) 10.52 8.44 10.60 8.50 10.69 8.57 10.77 8.64 10.86 8.71
1&79D 9319511
mm5% So Power Attenuation 98
91.2% _______________________________
$tantlartl my
87.7% - _____M°d�IFJiney STC(Standard Testing Conditions):Irradiance 1000W/m',Cell Temperature 25 C,Spectra atAM1.5
e Warra +3.35 NOCT(Nominal Operating Cell Temperature):Irradiance 80OW/m',Ambient Temperature 20 C,Spectra at AM1.5,Wind at lm/S
84.5%
80.7% Temperature Ratings(STC Mechanical Loading
Temperature Coefficient of Ise +OD57%/C Front Side Maximum Static Loading 5400Pa
1 5 10 15 20 25
Temperature Coefficient of Voc -0.286%/C Rear Side Maximum Static Loading 2400Pa
Complete System and Product Certifications Positive power tolerance(0^+5W)guaranteed Temperature Coefficient of Pmax -0.370%/C Hailstone Test 25mm Hailstone at the speed of 23ri
IEC 61215,IEC61730,UL1703
ISO 9001:2008:ISO Quality Management System High module conversion efficiency(up to 19.8%)
ISO 14001:2004:ISO Enylronment Management System Slower power degradation enabled by Low LID Mono PERC technology:first year<2%,
TS62941:Guideline for module design quallficatlon and typeapproval 0,55%year 2-25 Current-Voltage Cum[LR4-60HPH-360M) Power-Voltage Cum(LR4.60HPH-360M) Current-Voltage Cum(LR4.60HPH-360M)
OHSAS 18001:20D70ccupational Health and Safety
Solid PID resistance ensured by solar cell process optimization and careful module ROM 12
In
cOks ` selection aam an
-In[een nae.
Reduced resistive loss with lower operating current -
38 ' �a
xspeciflcations'I'*ttotechnlca[changes and tests.LONGi sofa, Higher energy yield with lower operating temperature
reserves the right ofinerpretauon.
Reduced hot spot risk with optimized electrical design and lower operating current
0 1° vaagemc o io y vem w o io y ee Mao w
LON�' Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China N�' Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China
Tel:+86-21-80162606 E-mail:module@Iongi-silicon.com racebook:www.facebook.com/LONGi Solar Tel:+86-21-80162606 E-mail:module@longi-silicon.mm racebook:www.facebook.com/LONGi Solar
Nate:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONG,Sala,have the sole right to make Nate:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONG,Sala,have the sole right to make
such modification at anytlme without further notice;Demanding parry shall request for the latest datasheet for such as contract need,and make it a cans,sdng and binding part of such modification at anytlme without further notice;Demanding parry shall request for the latest datasheet for such as contract need,and make it a canzistog and binding part of
III documentation duly signed by both partie, lawful documentation duly signed by both parties.
V10 V10
/ Single Phase Inverter
Wit HD-Wave Technology for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
Sin le Phase Inverter Z SE760OH-US / SE10000H-US / SE1140OH-US
9 SE300OH-US SE380OH-US SE500OH-US SE600OH-US SE760OH-US SE1000OH-US SE1140OH-US
• OUTPUT
with HD-Wave TechnologyRated AC Power Output 3000 3800 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
or NorthAmerica AC Output Voltage Min.-Nom.-Max. � V V V Vac
SE3000H-LIS / SE38001-1-US / SE50001 I .1_►S / SE-6000Fl-US / �,.. _ AC Output
-264,
AC Voltage Min.-Nom.-Max. Vac
SE7600H-LIS / 5E10000H-US / S1: 114( i�►1 I-US ACFre Frequency
AC Frequency(Nominal) 59.3-60-60.501 Hz
FMaximum Continuous Output 12.5 16 21 25 32 42 47.5 A
..A
Current @240V
Maximum Continuous Output - 16 24 48.5 A
> �0—• Current @208V
GFDI Threshold 1 A
Utility Monitoring,Islanding
0 solar=3 , )f) ` Protection,Country Configurable Yes
Thresholds
INPUT
• M Maximum DC Power @240V 4650 5900 7750 9300 1 11800 11 15500 17650 W
Maximum DC Power @208V - 5100 7750 - 15500 W
O Transformer-less,Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current @240VO 8.5 10.5 13.5 16.5 20 27 30.5 Adc
0 0 Maximum Input Current @208V(4 - 9 13.5 - 27 Adc
i -� �1. • Max.Input Short Circuit Current 45 Adc
• Reverse-Polarity Protection Yes
O y I Ground-Fault Isolation Detection 600ko Sensitivity
Maximum Inverter Efficiency 99 99.2 %
CEC Weighted Efficiency 99 99 @ 240V %
98.5 @ 208V
O 0 O Nighttime Power Consumption <2.5 W
W • ADDITIONAL FEATURES
Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional)
Revenue Grade Data,ANSI C12.20 Optional()
Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect
Optimized installation with HD-Wave technology 2017690.12
STANDARD COMPLIANCE
Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07
/ Specifically designed to work with / Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI)
power optimizers Emissions FCC Part15 Class B
/ Record-breaking efficiency / Built-in module-level monitoring INSTALLATION SPECIFICATION`
AC Output Conduit Size/AWG 3/4'minimum/14-6 AWG 3/4"minimum/14-4 AWG
Range
/ Fixed voltage inverter for longer strings / Outdoor and indoor installation DC Input Conduit Size/#of Strings/ 3/4°minimum/1-2 strings/14-6AWG 3/4"minimum/1-3 strings/14-6AWG
AWG Range
Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/
/ Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data,ANSI C12.20 (HxWxD) mm
NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5%accuracy) Weight with Safety Switch 22/10 125.1/11.4 26.2/11.9 38.8/17.6 Ib/kg
Noise <25 <50 dBA
/ UL1741 SA certified,for CPUC Rule 21 grid Cooling Natural Convection
compliance Operating Temperature Range -40 to+140/-25 to+60)'O(-40'F/-40"C option) 'F/'C
Protection Rating NEMA 4X(Inverter with Safety Switch)
n)For other regional settings please contact SolarEdge support
s o lar m A higher current source may used;the inverter will limit its input current to the values stated
SE*Revenue grade inverter P/N:SEpoocH-USOOONNC2
Bolaredge.comra For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
18-40 version P/N:SE)coocH-USOOONNU4
®SolarEdge Technologies,Inc.All rights reserved.SOI.AREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc All Ro H S
other trademarks mentioned herein are trademarks of their respective owners.Date:1Z/2018N01/ENG NAM.Subject to change without notice.
Mill Power Optimizer
Power Optimizer O Frame-Mounted
P370/ P401/ P404/ P500
Frame-Mounted P370 P40 P404 P500
OPTIMIZER MODEL
MODULE (FOR HIGH-POWE (FOR HIGH POWER (FO 60-CELLAND (FOR 96-CELL
P370/ P401/ P404/ P500 I MODULES) STRINGS)
m INPUT
Rated Input DC P—rn 370 400 403 500 W
Absolute Maximum Input Voltage 60 80 Vdc
(Voc at lowest temperature)
MPPT Operating Range 8-60 12.5-80 8-80 Vdc
O Maximum Short Circuit Current asc) 11 11.75 11 10.1 Adc
Maximum Efficiency 99.5 %
-- Weighted Efficiency 98.8 %
Mill Overvoltage Category 11
OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15 Adc
Maximum Output Voltage 60 85 60 Vdc
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 f 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
N Safety IEC62109-1(class II safety),UL1741
ROHS Yes
MFire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Maximum Allowed System Voltage 1000 Vdc
Dimensions(W x L x H) 139 x 165 x 40/5.5 x 6.5 x 1.6 129x 113
602.0 x 29.x 1.16 5/5.08x 139 x 165 x 48/5.5 x 6.5 x 1.9 mm/in
Weight(including cables) 775/1.7 655/1.5 895/2.0 870/1.9 gr/lb
Input Connector MC4m
Input Wire Length 0.16/0.52 m/ft
Output Connector MC4
Output Wire Length 1.2/3.9 m/ft
Operating Temperature Ranges) -40 to+85/-40 to+185 'C/'F
Protection Rating IP68/NEMA6P
Relative Humidity 0-100 %
Fast mount power optimizers with module-level optimization (1)Rated powerofthe modul—t STC will not exceed the optimizes"Bated Input DC Pi Modules with up to+5%Power tolerenceareallowed
(2)For other connector types please contact SolarEdge
(3)For ambient temperature above+85-C/+185-F power de-rating is applied.Refer to Power Optimizers Ten perature De-Rating Technical Note for more details
/ Specifcally designed to work with SolarEdge / Mitigates all types of modules mismatch-loss,
inverters from manufacturing tolerance to partial shading PV SYSTEM DESIGN USING SINGLE THRE
/ Quicker installation-Power optimizers can be / Flexible system design for maximum space A SOLAREDGE INVERTER(4) PHASE PHAS Supported
mounted in advance saving installation time utilization P370/ frame
Minimum String Length P403,/ 8 l6 18 cross section
/ Up to 25%more energy / Next generation maintenance with module level (Power Optimizers)
monitoring P404 6 14(13 with SE31Q- 14 7
Maximum String Length(Power Optimizers) 25 50 50
/ Superior efficiency(99.5%) / Module-level voltage shutdown for installer and
g Maximum Nominal Power per String 5700m 1 5250P- 11250- 12750 W
firefighter safe 1.1-2.2mm/
g Parallel Strings of Different Lengths Yes 0.04-0.09in
or Orientations
(4)It is not allowed to m ix P404 with P370/P401/P500 in one string
(5)The P370/P401/P500 cannot be used with the SE3K three phase inverter(available in some cou ntries:refer to Three Phase Inverter SE3K-SE10K datashee[j >12mm/0.48in
(6)Exactly 10 when using SE3K-RW010BNN4
p)If the imnrt—rated AC power<maximum nominal power per string,than the maximum power per string will be able to reach up to the inverters maximum
input DC power Refer to:https:A/ .solaredge.com/sites/default/fil,s/se-power-optimizer-single-string-design-application-n,te.pdf
(8)For SE27.6K,SE55K,SE82.8K:It is allowed to install up to 13,501 per string when 3 strings are connected to the inverter and when the maximum power
solar=@@
difference between the strings is up to 2,1 inverter max DC power:37,250W
solaredge.eom ®INiedge ll,irdogiex al ii,li re:er.ed 10 moe the Weredge logo,OMMRED BY SMA—Eare trA— &WNrEdge Ti su h 1nc.
All CE
oMertr nerb mendaned herein are trademark:oftheir rezpe— n owers.Pate:12/2020/VOVEW ROW. bjectta t nge wkhout notice.
0 o
SFMINFINITY one.. IRA .. N I RA
BETTER SOLAR STARTS HERE DESIGN GUIDELINES BETTER SOLAR STARTS HERE
Take your business to the next level with SFM INFINITY, UNIRAC's rail-less PV mounting system for flush
While you will see advantages simply from switching to SFM INFINITY, the following guidelines will help you
mount installations on comp shingle and the roofs. An advanced 3rd generation product platform in use
to maximize its benefits,
by top solar contractors nationwide, SFM INFINITY optimizes your operations on and off the roof, with
approximately 40% less labor, 30% logistics savings, and 20% fewer roof attachments than traditional
solar racking. Plus, 87% of homeowners prefer SFM INFINITY's aesthetics. DEFAULT TO LANDSCAPE
OUNIRAC When possible,design in landscape orientation in order to fit more modules on
the roof and minimize roof attachments.
25
Y AR MIX MODULE ORIENTATIONS
WAHRANTY SFM INFINITY is easily configured in mixed array shapes and module orientations to maximize array
density and to avoid vent pipes and other obstacles.Because mounting locations are not constrained
by rails,SFM INFINITY has unmatched flexibility to enhance your projects.
UNIVERSAL COMPONENTS CONSULT THE QUICK TIPS VIDEOS
FIT 32 - 40MM MODULES Visit UNIRAC's mobile-friendly library of short,topic-specific videos which answer common questions
and demonstrate how simple it is to install SFM INFINITY.
Quick Tips Videos:https://unirac.com/SFM-Infinity/ INSTAU TRIM RAN,ROOFATTACHMENTS
+ ►
Pill
DESIGN IN U-BUILDER
I
Layout your arrays in U-Builder,UNIRAC's free solar design software,to optimize SFM INFINITY's
• capabilities,including mixing module orientations and minimizing roof attachments.Quickly create
layouts on Google or Bing Maps and generate project documents.
SUPERIOR PERFORMANCE EASY INSTALLATION HOMEOWNER PREFERRED U-Builder:https:Hdesign.unirac.com/
Enhance your business with two installs per day Pre-assembled components,20%fewer roof attachments, More than 4 out of 5 homeowners prefer SFM INFINITY's
and 30%less cost. and level array in seconds with post height adjustment. aesthetics over a leading rail brand.
REVOLUTIONIZING ROOFTOP SOLAR
REVOLUTIONIZING
ROOFTOP SOLAR
FOR QUESTIONS 1 ' CUSTOMER SERVICE VISIT U N I'A C.C 0 M 0' I5) 248-2702 FOR QUESTIONS 0' CUSTOMER SERVICE VISIT U N I'A C.C 0 M 0'
Report No. 102393982LAX-002 Page 2 of 107 Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 3 of 107 Issued: 11-Apr-2016
Unirac, Inc Revised: 20-Mar-2019 Unirac, Inc Revised: 20-Mar-2019
2.0 Product Description 2.0 Product Description
Product Photovoltaic Mounting System, Sun Frame Microrail- Installed Using Unirac Installation Guide, Model Similarity NA
Fuse Rating: 30A
Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20
Brand name Unirac Module Orientation: Portrait or Landscape
The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Maximum Module Size: 17.98 ft2
Rack Mounting System. This system is designed to provide bonding and grounding to UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope
photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope
that are roof mounted using the slider, outlined in section 4 of this report. There are no rails Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading
within this product, whereas the 3" Micro Rail, Floating Splice, and 9"Attached Splice
electrically bond the modules together forming the path to ground. Increased size ML test:
Maximum Module Size: 22.3 ft2
The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope
with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the LG355S2W-A5 used for Mechanical Loading test.
modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate Mounting configuration: Four mountings on each long side of panel with the longest span of
Description the anodized coating of the photovoltaic module frame to contact the metal, creating a bonded 24"
connection from module to module. UL2703 Design Load Rating: 46.9 PSF Downward,40 PSF Upward, 10 PSF Down-Slope
Ratings LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading
The grounding of the entire system is intended to be in accordance with the latest edition of the test.
National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Six mountings for two modules used with the maximum span of
Photovoltaic Systems. Any local electrical codes must be adhered in addition to the 74.5"
national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in
accordance with the installation manual provided in this document. Fire Class Resistance Rating:
-Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any
Other optional grounding includes the use of the Enphase UL2703 certified grounding system, interstitial gap. Installations must include Trim Rail.
which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any
engage cable. interstitial gap. Installations must include Trim Rail.
Models Unirac SFM -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules.
This system was evaluated with a 5"gap between the bottom of the module and the roof's
surface
See section 7.0 illustraction# 1 and la for a complete list of PV modules evaluated with these
racking systems
Other Ratings NA
ED 16.3.15(20-Apr-17)Mandatory ED 16.3.15(20-Apr-17)Mandatory
intertek AUTHORIZATION TO MARK
Total Quality.Assured.
This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s)
Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing
Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing
Report.
This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be
applied only at the location of the Party Authorized To Apply Mark.
Applicant: Unirac, Inc Manufacturer: Cixi Emeka Aluminum Co. Ltd
1411 Broadway Blvd NE No. 688 ChaoSheng Road
Address: Albuquerque, NM 87102 Address: Cixi City
Zhejiang Province 315311
Country: USA Country: China
Klaus Nicolaedis Jia Liu
Contact: Tom Young Contact: Robin Luo
505-462-2190 +86-15267030962
Phone: 505-843-1418 Phone: +86-13621785753
FAX: NA FAX: NA
klaus.nicolaedis@unirac.com
om
Email: toddg@unirac.com Email: ji buwan.luo@cxymj.com
buwan.luo@cxymj.com
Party Authorized To Apply Mark: Same as Manufacturer
Report Issuing Office: Lake Forest, CA U.S.A.
Control Number: 5003705 Authorized by:
for Dean Davidson, Certificati anager
c. US
LISTED
Intertek
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are
limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned
by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is
restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must
first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the
agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.
Intertek Testing Services NA Inc.
545 East Algonquin Road,Arlington Heights, IL 60005
Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672
Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-
Plate Photovoltaic Modules and Panels [UL 2703: 2015 Ed.1]
Photovoltaic Mounting System, Sun Frame Microrail - Installed Using Unirac Installation Guide, Rev
Product: PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FEB20
Brand Name: Unirac
Models: Unirac SFM
ATM for Report 102393982LAX-002 Page 1 of 1 ATM Issued: 9-Apr-2019
ED 16.3.15(20-Apr-17)Mandatory
to a Address:Intertek Colad NY 13 11 to ek Address:Intertek Colad NY 13 11
Cortland NY 13045 Cortland NY 13045
Total quality.Assured. Telephone: 607-758-6516 Total Quality.Assured. Telephone: 607-758-6516
www.intertek.com www.intertek.com
o SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/SE760OA-US/SE1000OA-US/
SE1140OA-US/SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE760OH-US/
Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements SE1000OH-US/SE1140OH-US when the following label is labeled on the side of the
inverter:
To,whom it may concern Ir 's
This letter represents the testing results of the below listed products to the requirements contained in
the following Standards: --PHOTOVOLTAIC RAPID
National Electric Code, 2017,Section 690.12 requirement for rapid shutdown. SHUTDOWN SYSTEM
UL 1741, UL 1741 CRD for rapid shutdown
The evaluation was done on the PV Rapid Shutdown System (PVRSS),and covers installations consisting Inverter part number may be followed by a suffix
of optimizers and inverters with part numbers listed below.
The testing done has verified that controlled conductors are limited to: • 3-ph Inverters:
o SE9KUS/SEIOKUS/SE14.4KUS/SE20KUS/SE30KUS/SE33.3KUS/SE43.2KUS/
• Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation SE66.6KUS/SE100KUS;when the following label is labeled on the side of the inverter:
outside the array.
• Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation I$1172W&
inside the array.
The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter,or—if HOTOVOLTAIC RAPID
the inverter DC Safety switch is readily accessible—by turning off the DC Safety switch.
SHUTDOWN SYSTEM
Applicable products:
Inverter part number may be followed by a suffix
• Power optimizers:
o PB followed by 001 to 350;followed by-ACB or-TFI. If there are any questions regarding the results contained in this report,or any of the other services
OP followed by 001 to 500;followed by-LV,-MV,-IV or-EV. offered by Intertek, please do not hesitate to contact the undersigned.
P followed by 001 to 850.
SP followed by 001 to 350.
*When optimizers are connected to 2 or more modules in series,the max input voltage
may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value
of 80V max inside of the array at the beginning of 2019, modules exceeding this
combined input max voltage will be required to use optimizers with parallel inputs.
• 1-ph Inverters:
This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party, Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,
other than to the Client in accordance with the agreement,for any loss,expense,or damage occasioned by the use of this information. other than to the Client in accordance with the agreement,for any loss,expense,or damage occasioned by the use of this information.
Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and
distribute this information and only then in its entirety. distribute this information and only then in its entirety.
©2018 Intertek ©2018 Intertek
Version:8-September-2016 Page 1 of 3 GFT-OP-110a Version:8-September-2016 Page 2 of 3 GFT-OP-10a
AL
Ceftificate TUV Rheinland PTL.
Certificate no.
US 82160015 01
License Holder: Manufacturing Plant:
Unirac Inc, Unirac Inc.
1.411 Broadway NE 1.411 Broadway NE
Albuquerque NM 87102 Albuquerque NM 87102
USA USA
Test report no.: USA- 3144 0029 0 05 Client Reference: Tom Young
Tested to: UL 2 7 0 3:2 015
Certified Product; Module Rack Mounting System License Fee-Units
Model Designation: SolarMount (SM) 7
Max System Voltage of PV Module: 1000 VDC
Max Size of PV Module: 20.8 sq. ft. surface area
Max ❑vercurrent Protection Rating of PV Module:
30 A when using the qualified grounding lugs;
20 A when using the Enphase micro inverter EGC.
Fire Rating: Class A when installed with
Type 1, Type 2, Type3, or 'Type 10 fire rated modules.
(continued)
7
Appendix: 1, 1-5
Licensed Test mark: Date of Issue
(daylmolyr)
27/07/2016
TOVRheinland
us
TUV Rheinland PTL,LLC,1107 W.Fairmont Drive,Building A,Tempe,Arizona 85282,Tel(480)966-1700,Fax(775)314-6458
P7
LE
structural
ENGINEERS
July 30, 2020
Unirac
1411 Broadway Blvd. NE
Albuquerque, NM 87102
Attn.: Unirac- Engineering Department
Re: Engineering Certification for the Unirac Sunframe Microrail, SFM Infinity U-builder Software Version 1.0
PZSE, Inc. -Structural Engineers has reviewed the Unirac's Sunframe Microrail, proprietary mounting system constructed
from modular parts which is intended for rooftop installation of solar photovoltaic(PV) panels; and has reviewed the U-
builder Online tool.This U-Builder software includes analysis for the 2" Microrail, 8"Attached Splice, 6" splice, and front
trimrail. All information, data and analysis contained within are based on, and comply with the following codes and
typical specifications:
1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05,ASCE/SEI 7-10, ASCE/SEI 7-16
2. 2018 Connecticut State Building Code
3. 2006-2018 International Building Code, by International Code Council, Inc.w/Provisions from SEAOC PV-2 2017.
4. 2006-2018 International Residential Code, by International Code Council, Inc.w/Provisions from SEAOC PV-2
2017.
S. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November
1, 2012 by ICC-ES.
Following are typical specifications to meet the above code requirements:
Design Criteria: Ground Snow Load =0- 100 (psf)
Basic Wind Speed =90- 180 (mph)
Roof Mean Height=0-30 (ft)
Roof Pitch =0-45 (degrees)
Exposure Category= B, C& D
Attachment Spacing: Per U-builder Engineering report.
Cantilever: Per U-builder Engineering report.
Clearance: 2"to 10" clear from top of roof to top of PV panel.
Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation.
Installation Orientation: See SFM Installation Guide.
Landscape- PV Panel long dimension is parallel to ridge/eave line of roof and the PV
panel is mounted on the long side.
Portrait- PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel
is mounted on the short side.
Attachment shall be staggered where ground snow load exceeds 10 PSF.
1478 Stone Point Drive, Suite 190, Roseville, CA 95661
916.961.3960 916.961.3965 vv www.pzse.corn Page 1 of 2
E-xperience J inlegiily k Empowern-,eni
Testing: Values were based on UTR-299 testing provided by Unirac.
Components and Cladding Roof Zones:
The Components and Cladding Roof Zones shall be determined based on ASCE 7-05,ASCE 7-10&7-16 Component and
Cladding design.
Notes: 1) U-builder Online tool analysis is only for Unirac SFM Sunframe Microrail system only and do not
include roof capacity check.
2) Risk Category II per ASCE 7-16.
3)Topographic factor, kzt is 1.0.
4)Array Edge Factor YE= 1.5
5)Average parapet height is 0.0 ft.
6) Wind speeds are LRFD values.
7)Attachment spacing(s) apply to a seismic design category E or less.
Design Responsibility:
The U-Builder design software is intended to be used under the responsible charge of a registered design professional
where required by the authority having jurisdiction. In all cases,this U-builder software should be used under the
direction of a design professional with sufficient structural engineering knowledge and experience to be able to:
• Evaluate whether the U-Builder Software is applicable to the project, and
• Understand and determine the appropriate values for all input parameters of the U-Builder software.
This letter certifies that the Unirac SFM Sunframe Microrail,when installed according to the U-Builder engineering
report and the manufacture specifications, is in compliance with the above codes and loading criteria.
This certification excludes evaluation of the following components:
1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength
and deflection of structural framing members,fastening and/or strength of roofing materials, and/or the effects
of snow accumulation on the structure.
2) The attachment of the SFM 2" Microrail or 8"Attached Splice to the existing structure.
3) The capacity of the solar module frame to resist the loads.
This requires additional knowledge of the building and is outside the scope of the certification of this racking system.
If you have any questions on the above, do not hesitate to call.
Prepared by: DIGITAL SIGNATURE
PZSE, Inc.—Structural Engineers 11lil ffff
Roseville, CA QV '`��
N0. T3522
f k
r r
•
STATE
f'��'`**fib�R l��'#•�*���'�
Page 2 of 2