Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE 9-10-21 Planning& Development Services Department RECEIVED o Building&Code Regulations Division _... ,._. 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 SEP Y,® 2021 Certification for Design Load Compliance ot,W910 Cowfily Pam"Ing Project Name: CASA CAPRONA STAIRS Project Address: 2605 ST.LUCIE BLVD. Permit#: '41'�(� Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: •This certification must be completed,signed,and sealed by the design professional of record. •Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) 1.DESIGN CODE:Florida Building Code 2020 7th Edition with 20 Supplements using ASCE 7-16 2.Structure Designed as(check one): X Enclosed _Partially Enclosed Open 3.Risk Category: _I X II III IV Exposure Category: X B_C D 4.Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width_ 5 ft S.Mean Roof Height: 20 ft Roof Pitch: N/A :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): 16.0 16.0 16.0 27.6 27.6 N/A Zone 1: _25.3 Zone 2: _44.0 Zone 3: -65.1 Zone 4: -30.0 Zone 5: -37.0 Garage: N/A 7.Design Loads:Floor: 100 PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: 100 PSF Fence: N/A PSF Railings: 200 PLF/CONCENTRATED 8.Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9.Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best ofrmy knowledge and belief,the attached plans&specifications have been designed to comply with the aplilicablefstr�ictura,I portions of the building codes currently adopted and enforced by St. Lucie County.I also certifyh�at�strci� r'al elements depicted on these plans provide adequate resistance to the design � R 4 forces specified Paul Welch P.E. 29945 / 5115 Print Name Cert#&Co.Cert Auth. 4 Paul Welch Inc. Signature,Date,ra d Se'al 1984 S.W. Biltmore St. Suite#114 Port St. Lucie, FL � Oda.�\� Company Name&Address SLCCDV Form y Fy L iv